Marine Engineering Practice MEP Questions and Answers-Part 5
Marine Engineering Practice MEP Questions and Answers-Part 5
Answers- Part 5
In this article get to know about boiler burner maintenance, fuel injector testing, CO2 line
testing, cylinder head testing and HP cut out problems in details. Here are some of the most
common questions that are framed out of the problems that are faced in the common
machinery.
Some of the answers have been taken from social discussions as well.
(http://4.bp.blogspot.com/-
qs2F8GXA7Ec/VO2FaypskVI/AAAAAAAAAj8/NHvHsaQ5XLM/s1600/MEP%2BSeries.png)
In case of a boiler gauge glass showing water level is empty how can you correct
way of find water in boiler?
· First stop the boiler.
· Then check other means of reading. Like remote gauge or other gauge.
· Blow through the gauge glass and when everything is normal then start the boiler again.
Keep an eye on the parameters.
What Happens When Hp Cut Out Not Operational In Refrigeration System?
Well for this we have protection system. Main protection is v-belt driven arrangement is
there as protection for overload of refer compressor. In case hp trip not working and
compressor is overloaded, belt will give away to protect compressor. Also if HP cut out not
working, Relief valve will operate on condenser side.
So this was all from this article. Hope you enjoyed reading this.
Google (https://plus.google.com/share?
url=http://www.marinersgalaxy.com/2015/08/marine-engineering-practice-mep-
questions.html)
Twitter (https://twitter.com/intent/tweet?
text=Marine%20Engineering%20Practice%20MEP%20Questions%20and%20Answers-
%20Part%205%20-
%20Shipping%20Industry&url=http://www.marinersgalaxy.com/2015/08/marine-
engineering-practice-mep-questions.html)
More