Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

ABU DHABI SEWERAGE SERVICES COMPANY

(ADSSC)

DESIGN GUIDELINES

SECTION 6

STANDARD AND TYPICAL DRAWINGS

Design Standard and Typical


ADSSC/DG Section 6 Rev: 04 May 2015 Page 1 of 6
Guidelines Drawings
Design Guidelines
Abu Dhabi Sewerage Services Company
(ADSSC)

DOCUMENT CONTROL SHEET

Revision
Date Revision Description / Purpose of Issue
No.

01 April 2008 First Issue.

Jan. 2011 ADSSC new logo


02

List Updated to include Drawings Numbers


Mar. 2013
03 403A, 803A, 808A, 808B & 808C
List updated to include Forty Two (42) additional
drawings those are added in May 2015 Revision
SD301.1_HDPE & PP, SD301_GRP, SD301_HDPE & PP
SD301_HDPE & PP, SD301A_GRP, SD302_GRP,
SD302_HDPE & PP, SD303_GRP, SD303_HDPE & PP,
May 2015 SD304_GRP, SD305_GRP, SD306_GRP, SD306_HDPE & PP,
04 SD307_HDPE & PP, SD310_HDPE & PP, SD310A_GRP,
SD310B_GRP, SD310C_GRP, SD310D_GRP, SD310E_GRP,
SD310F_GRP, SD311_HDPE & PP, SD312_HDPE & PP,
SD313_HDPE & PP, SD806A, SD808D, SD808E, SD822A,
SD822B, SD822C, TD102, TD559, TD560, TD561, TD562,
TD563, TD564, TD565, TD566, TD567, TD568, TD569

05

06

07

08

09

10

Design Standard and Typical


ADSSC/DG Section 6 Rev: 04 May 2015 Page 2 of 6
Guidelines Drawings
Design Guidelines
Abu Dhabi Sewerage Services Company
(ADSSC)

STANDARD DRAWINGS

SEWERAGE SYSTEM: SD300 SERIES

Number Brief Title

SD301 G.A. of Foul Sewerage Manholes on 150-500mm Dia. Pipelines.


SD301.1_HDPE & PP General Structural Details of Manholes (Applicable ≤ 7.5M )
SD301_GRP G.A. of DN 1500mm Structural Manhole (with anti-flotation base)
SD301_HDPE & PP G.A. Foul Sewerage Manhole on 110 – 315mm Dia Pipelines (Type 1B)
SD301A_GRP G.A of DN 1500mm Structural Manhole (Shallow Manhole)
SD302 G.A. of Foul Sewerage Manholes on 600-1600mm Dia. Pipelines. Sheet 1
of 2
SD302_GRP G.A. of DN 1800mm Structural Manhole (with anti-flotation base)
SD302_HDPE & PP G.A of Foul Sewer Manhole on 400 – 1400mm Dia. Pipelines
SD303 G.A. of Foul Sewerage Manholes on 600-1600mm Dia. Pipelines. Sheet 2
of 2
SD303_GRP G.A. of DN 2000mm Structural Manhole (with anti-flotation base)
SD303_HDPE & PP G.A. of Fuel of Sewerage Manhole on 400 – 1400mm Dia. Pipelines
SD304 G.A. of Foul Sewerage Manholes on Pipelines 1800-2400mm Dia.
Sheet 1 of 2
SD304_GRP G.A. of 1800mm – 1500mm Structural Manhole (with Anti Flotation Base &
Reduced Slab)
SD305 G.A. of Foul Sewerage Manholes on Pipelines 1800-2400mm Dia.
Sheet 2 of 2
SD305_GRP G.A. of DN2000 – 1500mm Structural Manholes (with Anti Flotation Base &
Reduced Slab)
SD306 Connection Details for Sewerage Manholes & Chambers
SD306_GRP Typical Backdrop & GRP Joint Lamination Details
SD306_HDPE & PP Connection Details for Manholes & Chambers
SD307 Cover Details for Foul Sewerage Manholes & Chambers
SD307_HDPE & PP Cover details for HDPE Manholes & Chambers
SD308 GRP Liner Joint Details for Sewerage Manholes & Chambers
SD309 Not Used
SD310 Collection and Inspection Chambers Details
SD310_HDPE & PP Collection & Inspection Chamber details (Type – 1A)
SD310A_GRP DN 900mm Collection & Inspection Chambers
SD310B_GRP DN 900mm Collection & Inspection Chambers
SD310C_GRP DN 1000mm Collection & Inspection Chambers
SD310D_GRP DN 1000mm Collection & Inspection Chambers (with Anti-Floatation Base)
SD310E_GRP DN 1000mm Collection & Inspection Chambers (With Modified Benching)
SD310F_GRP DN 1000mm Collection & Inspection Chambers (With Modified Backdrop)
SD311 Small Rectangular Inspection Chambers & House Connection Details
SD311_HDPE & PP Small Circular Inspection Chambers & House Connection Details
SD312_HDPE & PP Standard Details
SD313_HDPE & PP Manholes Base Details

Design Standard and Typical


ADSSC/DG Section 6 Rev: 04 May 2015 Page 3 of 6
Guidelines Drawings
Design Guidelines
Abu Dhabi Sewerage Services Company
(ADSSC)

SEWAGE PUMPING MAIN: SD400 SERIES

Number Brief Title

SD401 Discharge Chamber for Sewage Pumping Main


SD402 Pumping Main Marking Details
SD403 Typical Details of Lettering on Manhole Cover

SD403A Manhole Top & GRP Dealing Plate Details


SD404 ADSSC Logo for Sewer Manhole Cover Plate

SEWAGE PUMPING STATION: SD500 SERIES

Number Brief Title

SD501 Not Used


SD502 Not Used
SD503 Builders Works Floor Details and Surface Finish
SD504 Builders Works Roof Slab and Parapet Details

MISCELLANEOUS SITE WORKS: SD800 SERIES

Number Brief Title

SD801 Pipe Bedding & Backfill Details


SD802 Thrust Blocks General Arrangement
SD803 Detail of Internal Backdrop on Existing Manhole
SD803A Typical Details of Trade Effluent Discharge Point
SD804 Adjusting Cover Levels for Manhole & Collection Chamber - Typical Details
SD805 Tanking Details
SD806 Sand Trap and Grease Trap
SD806A Grease Traps (Type A & B)
SD807 Petrol Interceptor Type - I
SD808 Petrol Interceptor Type - II
SD808A Sewerage Holding Tank – Type A1 to A7
SD808B Sewerage Holding Tank – Type A8 to A10
SD808C Sewerage Holding Tank – Type A11
SD808D Septic Tank Type – Standard
SD808E Typical Carwash Interceptors
SD809 Collection Tank to Petrol Interceptor
SD810 Typical GRP Ladder
SD811 Ladder, Walkway, Stairs & Hand-railing Details
SD812 Not Used
SD813 Blockwork Boundary Wall Details Sheet 1 of 2
SD814 Blockwork Boundary Wall Details Sheet 2 of 2
SD815 Precast Boundary Wall Details Sheet 1 of 2
SD816 Precast Boundary Wall Details Sheet 2 of 2
SD817 Sewage Pumping Station Aluminium Site Entrance Gate

Design Standard and Typical


ADSSC/DG Section 6 Rev: 04 May 2015 Page 4 of 6
Guidelines Drawings
Design Guidelines
Abu Dhabi Sewerage Services Company
(ADSSC)

SD818 Not Used


SD819 Cable Draw Pits. Earth Pits and Cable Ducts Details
SD820 Street Lighting Works 8.0m Pole Details
SD821 Paving Details
SD822A Chain Link Fence (Typical Details)
SD822B Chain Link Fence (Accessories)
SD822C Chain Link Fence (Anti Intruder Type)

TYPICAL DRAWINGS

GENERAL TD100: SERIES

Number Brief Title

TD100 Project Sign Board


TD101 Site Safety Notice Board
TD102 Sign Board Details

SEWAGE PUMPING MAIN: TD400 SERIES

Number Brief Title

TD400 Pumping Main Overall Plan For Reference Only


TD401 Typical Drawing Plan and Profile For Reference Only

SEWAGE PUMPING STATION: TD500 SERIES

Number Brief Title

TD500 Not Used

TD501 Two Pump Submersible General Arrangement Plan (With Options)–


1 of 2
TD502 Two Pump Submersible General Arrangement Plan (With Options)-
2 of 2
TD503 Control Building Sheet 1 of 2
TD504 Control Building Sheet 2 of 2
TD505 Control Building & Generator Building Sheet 1 of 3
TD506 Control Building & Generator Building Sheet 2 of 3
TD507 Control Building & Generator Building Sheet 3 of 3
TD508-551 Not Used
TD552 Draft Process & Instrumentation Diagram
TD553 Typical Arrangement Drawing Sheet 1 of 3
TD554 Single Line Diagram Sheet 2 of 3
TD555 Standards Symbols Sheet 3 of 3
TD556 Not Used
TD557 Typical Drawing Weather Proof Junction Box
Design Standard and Typical
ADSSC/DG Section 6 Rev: 04 May 2015 Page 5 of 6
Guidelines Drawings
Design Guidelines
Abu Dhabi Sewerage Services Company
(ADSSC)

TD558 Pumping Station Typical P&ID


TD559 Primary Flow Meter Chamber – Typical Arrangement – 1
TD560 Verification Flow Meter Chamber – Typical Arrangement – 2
TD561 Take-Off Connection Chamber Type Arrangement
TD562 Flow Control Valve Chamber Typical Arrangement
TD563 Shut-Off Valve Chamber Typical Arrangement
TD564 General Arrangement for GRP Kiosk Including Sampling Point – 1
TD565 Typical Connection Details Between ADSSC & User 1
TD566 Typical Connection Details Between ADSSC & User 2
TD567 Typical P&ID Take-Off Connection Chamber (SV+FCV+FM+SV)
TD568 Typical P&ID Take-Off Connection Multiple Chamber
TD569 General Arrangement for GRP Kiosk including Sampling Point - 2

MISCELLANEOUS SITE WORKS: TD800 SERIES

Number Brief Title

TD801 Thrust and Receiving Pits Details Sheet1


TD802 Thrust and Receiving Pits Details Sheet 2
TD803 Pipe Details

MISCELLANEOUS RC DETAILS: RD 300 SERIES

Number Brief Title

RD300 Sewerage Manhole & Chamber Cover Slab R.C. Details


RD301 Sewerage Standard 1500 mm DIA Base Slab R.C. Details
RD302 Sewerage Standard 2000mm DIA Base and Reducer Slab R.C. Details

END OF SECTION

Design Standard and Typical


ADSSC/DG Section 6 Rev: 04 May 2015 Page 6 of 6
Guidelines Drawings

You might also like