See discussions, stats, and author profiles for this publication at: https://www.researchgate.

net/publication/277041049

Bulb turbine hydraulic tests at the HPP 'Đerdap II'

Article · January 2006

CITATIONS READS

0 109

4 authors:

Miroslav Hilarius Benišek Ivan Bozic


University of Belgrade University of Belgrade
42 PUBLICATIONS   99 CITATIONS    36 PUBLICATIONS   49 CITATIONS   

SEE PROFILE SEE PROFILE

Dejan Ilić Djordje Cantrak


University of Belgrade Faculty of Mechanical Engineering, University of Belgrade, Belgrade, Serbia
17 PUBLICATIONS   62 CITATIONS    44 PUBLICATIONS   162 CITATIONS   

SEE PROFILE SEE PROFILE

Some of the authors of this publication are also working on these related projects:

Pr0ject for EPS HPS Djerdap 1 and 2. View project

Fab lab View project

All content following this page was uploaded by Ivan Bozic on 08 April 2016.

The user has requested enhancement of the downloaded file.


UDK: 359.42/621.22
Referat sa naučnog skupa

EKSPERIMENTALNA HIDRAULIČKA ISPITIVANJA


KARAKTERISTIKA CEVNE TURBINE HE “ĐERDAP II”
Prof. dr Miroslav BENIŠEK, Ivan BOŽIĆ, Dejan ILIĆ, Đorđe ČANTRAK
Mašinski fakultet, Univerzitet u Beogradu

REZIME Hidraulička ispitivanja cevne turbine br. 9 dodatnog


agregata HE “Đerdap II” izvršila je ekipa Mašinskog
U okviru ovog rada se prikazuju neki rezultati fakulteta Univerziteta u Beogradu – Centra za
garancijskih hidrauličkih ispitivanja cevne turbine hidraulične mašine i energetske sisteme u saradnji sa
agregata br.9 dopunske HE “Đerdap II”. Dati su uslovi ekipama Instituta ”Lola” i Instituta “Nikola Tesla”.
pod kojim je merenje izvršeno, kao i analiza dobijenih
rezultata. Merenja su obavljena na tri različita pada, 2 METODOLOGIJA ISPITIVANJA CEVNE
srednjih vrednosti: Hr = 6,62 m, Hr = 7,36 m i TURBINE
Hr = 11,77 m.
Metodologija merenja veličina pri hidrauličkim i
Ključne reči: HE, cevne turbine, hidraulika, ispitivanja energetskim ispitivanjima cevne turbine br. 9 u okviru
garancijskih ispitivanja hidroagregata u dodatnoj
hidroelektrani “Đerdap II” je zasnovana na normama
1 UVOD IEC [9], na iskustvu stručnjaka Mašinskog fakulteta i
istraživanja koja su sprovedena u Centru za hidraulične
Hidroelektrana “Đerdap II” nalazi se na reci Dunav 82 mašine i energetske sisteme Mašinskog fakulteta
km nizvodno od HE “Đerdap I”. Srpski deo elektrane Univerziteta u Beogradu.
opremljen je sa deset cevnih hidroagregata. Cevni
agregat se sastoji iz hirauličke cevne turbine prečnika Na Slici 1. data je principska šema veze merne opreme
obrtnog kola D = 7,5 m sa obtnim kolom na konzoli, na agregatu br. 9 dodatne HE “'Đerdap II”', a u
cevnog sinhronog generatora prečnika kućišta 9,0m sa narednim potpoglavljima je opisano izračunavanje
vodenim hlađenjem rotora i statora i sa tiristorskim potrebnih fizičkih konstanti, metodologija i način
sistemom pobude i pomoćnih sistema agregata. merenja.

Pre više godina su obavljena kompleksna garancijska 2.1 Određivanje fizičkih konstanti
ispitivanja cevnih agregata na HE “Đerdap II”, na
agregatu br. 5 [2], [8], u kojima je, takođe učestvovao U okviru Tabele 1., dati su obrasci na osnovu kojih su
Mašinski fakultet Univerziteta u Beogradu. U toku određene neophodne fizičke konstante, dok su
nekoliko prethodnih godina su obavljena garancijska konstante korišćene u okviru izraza navedenih u ovoj
ispitivanja hidrauličke turbine na dodatnom agregatu br. tabeli, definisani u Tabeli 2. Vrednosti gustine,
9 na tri različita pada, srednjih vrednosti: Hr = 6,62 m, kinemtaske viskoznosti i specifičnog toplotnog
Hr = 7,36 m and Hr = 11,77 m [3]. kapaciteta za ulje M.30 (Tb – A.29) se očitavaju iz
dijagrama koji su navedeni u [3].

VODOPRIVREDA 0350-0519, 38 (2006) 222-224 p. 189-198 189


Eksperimentalna hidraulička ispitivanja karakteristika cevne turbine HE "Đerdap II" Miroslav Benišek i saradnici

Slika 1. Principska šema veze merne opreme na agregatu br.9 dodatne HE “Đerdap II”

Tabela 1. Određivanje fizičkih konstanti


Naziv fizičke konstante: Obrazac: Izvor:
(
g = 9,80617 ⋅ 1 − 2,64 ⋅ 10 −3 cos 2ϕG + 7 ⋅ 10 −6 cos 2 2ϕG ) formula
Ubrzanje Zemljine teže
− 3,086 ⋅ 10 − 6 zG Helmerta [5]
Gustina vode ρ = 1000,1800014 + 0,0084284θ − 0,0052857θ 2 [4]
−3
Gustina žive ρ Ž = 13595,08 − 2,47θ + 0,9693410 θ 3
[7]
(−16 ,921+ 396 ,13 (107 , 41+ θ ))
Viskoznost vode ν =e [4]

Tabela 2. Konstante u izrazima za određivanje fizičkih konstanti


Naziv fizičke konstante: Oznaka: Vrednost
:
nadmorska visina poda hale mašinske zgrade zG 32,75 m
geografska širina HE “Đerdap II” ϕG 44º20’0”
temperatura vode θ [ºC]
temperatura ulja M.30 (Tb – A.29) θu [ºC]

190 VODOPRIVREDA 0350-0519, 38 (2006) 222-224 p. 189-198


Miroslav Benišek i saradnici Eksperimentalna hidraulička ispitivanja karakteristika cevne turbine HE "Đerdap II"

Vrednost ubrzanja zemljine teže izračunata prema 2.3 Merenje protoka vode
izrazu i vrednostima konstanti navedenih u prethodnim
tabelama iznosi: g = 9,8055 (m/s2). Merenje protoka kroz turbinu se zasniva na metodi
Winter-Kennedy merenjem razlike pritisaka na
2.2 Merenje nivoa vode i padova pritisaka podagregatnom stubu pomoću manometra M.7-8.
Shema priključivanja manometra na podagregatni stub
Merenje nivoa vode i padova pritisaka je vršeno na više je data na Slici 2.
mernih mesta i to:
• nivo vode ispred rešetke, Protok prema metodi W.K. se određuje na osnovu
• nivo vode iza rešetke, formule:
• pad pritiska u rešetki i gubitak u rešetki,  ρ  (1)
Q = K ′ ∆p7 −8 = K p 1 − v ∆h7 −8
• pad pritiska i gubitak u niši brzog predturbinskog  ρ 
zatvarača,
• razlika pritisaka u presecima 1 i 4 (videti Slika 1.), Vrednost konstante Kp se određuje Indeks metodom, o
• razlika pritisaka u presecima 2 i 4 (videti Slika 1). kojoj će biti reči u poglavlju 2.12.

c
1
ρV
2 ρ
h7-8L ∆h7-8
RIP
∇KI7-8 0 0 h7-8D

M.7-8
∇12,25
.
Slika 2. Horizontalni presek podagregatnog stuba - shema priključivanja manometra M.7-8.

2.4 Merenje pada  z − z3  Q 2  1 1 


H =  z2 − z4 − 2 +  2 − 2  (2)
 2  2 g  AA AB 
Pad turbine se određuje po preporukama IEC 60983-
191 [9]. Referentni preseci su sledeći: ulaz A-A u gde se površine AA = 241,79m 2 i AB = 165,12m 2
turbinu je srednji presek niše brzog preturbinskog određuju na osnovu geodetskih premera.
zatvarača (BPZ), a izlaz B-B iz turbine je presek koji
prolazi kroz priključak IV (videti Sliku 1.). Neto pad 2.5 Određivanje bruto pada
turbine je:
Bruto pad turbine se određuje kao razlika nivoa vode u
p − pB c2 − c2 preseku I i preseku IV.
H= A + z A − zB + A B
ρg 2g
2.6 Određivanje gubitaka snage u ležajevima turbine
Primenom svega prethodno rečenog i uzimajući u obzir
osnovne jednačine mehanike fluida, dobija se Mehanički gubici u ležajevima turbine: aksijalnom A i
definisanje neto pada na sledeći način: radijalnom R3, povećavaju unutrašnju energiju ulja i

VODOPRIVREDA 0350-0519, 38 (2006) 222-224 p. 189-198 191


Eksperimentalna hidraulička ispitivanja karakteristika cevne turbine HE "Đerdap II" Miroslav Benišek i saradnici

kućišta tako da se gubitak snage ∆Pg u ležaju može gustina ulja za temperaturu θ um ; Qu (m3/s) - protok ulja
prikazati izrazom: ∆Pgi = c pu Qu ρ u (θ i − θ u ) + q , gde su kroz ležaj. Protoci ulja Qui kroz ležajeve turbine:
c pu (J/kgK) - specifična toplota ulja pri p = const. aksijalni ležaj A i radijalni ležaj R3, kao i protoci ulja
kroz generatorske ležajeve mere se pomoću
nestandardnih blendi. Protoci ulja se određuju na
Vrednosti specifične toplote ulja date su u poglavlju
osnovu formule: Qui = α Bi Aαi 2 ∆pi ρu , gde su:
2.1. Vrednost c pu se uzima za srednju temperaturu ulja
indeks i- označava aksijalni A ili radijalni R3 turbinski
θ um = 0 ,5(θ i + θ u ) ; θu i θ i ( C ) – tempetaure ulja na
o
ležaj; α Bi [−] - koeficijent protoka blende.
ulazu i izlazu iz ležaja (videti Sliku 3.); ρ u (kg/m3) -

Slika 3. Principska šema vezivanja mernih instrumenata radi merenja gubitaka u ležajevima

Nestandardne blende, date geometrije u [3], su karakterišu strujanje sa razmenom toplote. Izračunate
izbaždarene, i korišćene pri merenju na padovima vrednosti qi obično su u odnosu na vrednosti ∆Pgi male
H r = 6,62m i H r = 11,77m , dok su pri merenju na padu i mogu se zanemariti te se prilikom računa nisu uzimale
H r = 7 ,36m promenjene blende za merenje protoka ulja u obzir.
na ležajevima R1, R2 i R3 ugrađene standardne blende
date geometrije u [3]. 2.7 Merenje snage turbine

Dalje, veličina q iz izraza za ∆Pgi , koja predstavlja Snaga na vratilu turbine između aksijalnog ležaja A i
radijalnog generatorskog ležaja R2 naziva se snagom
količinu toplote u jedinici vremena koja pređe sa kućišta
ležaja na zid, se određuje prema formuli McAdamsa: turbine PT .
qi = α i' Aki (θ ki − θ vi ) , gde se koeficijent prelaza toplote
Snaga turbine PT se određuje na osnovu izraza
( α i' ) računa prema jednačinama McAdamsa, u okviru
PT = PM + PgS + PgmG .
kojih figurišu odgovarajuće bezdimenzione veličine
koje

192 VODOPRIVREDA 0350-0519, 38 (2006) 222-224 p. 189-198


Miroslav Benišek i saradnici Eksperimentalna hidraulička ispitivanja karakteristika cevne turbine HE "Đerdap II"

Snaga gubitaka u statoru PgS je jednaka: korisnosti ηh uključen i volumetrijski stepen korisnosti,
PgS = PFe + PCu , gde su: PFe (kW) - snaga gubitaka u tj.: ηh = η′h ηQ .
gvožđu PFe = PFeN (U U N )2 , PFeN (kW) - snaga gubitaka
pri nominalnom naponu, U (V) – izmereni napon, UN = 2.11. Merenje ugla otvora obrnog kola i ugla otvora
6300 (V) – nominalni napon, PCu = PKS (kW) – snaga sprovodnog aparata
gubitaka u bakru namotaja. Određuju
U okviru ovih garancijskih ispitivanja prvo je utvrđena
se PKS = PKSn ( I I n ) , gde su: PKSn = 344,17 (kW) -
2
postojeća veza β= f (YOK ) i α SA = f (YSA ) , koja je
gubici pri nominalnoj struji statora. prikazana u [3], gde je ( β( º ) - ugao otvora radnog kola,
YOK ( mm ) - hod servomotora obrtnog kola , α SA ( º ) -
Mehanički gubici snage generatora PgmG se mogu ugao otvora sprovodnog aparata i YSA ( mm ) - hod
izraziti: PgmG = Pgv + PgR , gde su: Pgv (kW)- ventilatorski servomotora sprovodnog aparata). Na osnovu nje su,
gubici snage i PgR = PgR1 + PgR 2 (kW)- gubici snage u potom, određivane odgovarajuće vrednosti ugla otvora
radnog kola i sprovodnog aparata.
ležajevima generatora R1 i R2.

2.12. Baždarenja protokomera turbine - određivanje


2.8 Određivanje unutrašnje snage turbine
vrednosti koeficijenta protoka Kp protokomera
Unutrašnja snaga turbine Pi (snaga koju radno kolo
Koeficijent protoka K p protokomera-podagregatnog
preda vratilu turbine) se određuje na osnovu izraza:
stuba (videti poglavlje 2.3) određuje se indeksnom
Pi = PT + PgA + PgR3 = PT + PgmT , gde su: PT (kW) -
metodom [9] na osnovu obrasca:
snaga turbine na osnovu izraza u potpoglavlju 2.7; PgA i
 ρ 
PgR3 (kW) - gubici snage u aksijalnom (A) i radijalnom K p = Pi ρv gH ηh max ∆h7−8 1 − v 
 ρ
ležaju (R3), respektivno (određuju se iz izraza u
potpoglavlju 2.6); PgmT (kW) ukupna snaga mehaničkih gde su: Pi (kW) - unutrašnja snaga turbine; H (m) - neto
gubitaka u aksijalnom (A) i radijalnom (R3) ležaju. pad turbine; ∆h7−8 (m) - pokazivanje manometra M7-8 i
ηh max -najviši stepen korisnosti za dati propeler i pad
2.9 Određivanje hidrauličke snage turbine koji se uzima iz propelernih karakteristika dobijenih
preračunavanjem stepena korisnosti modela na original
Hidraulička snaga turbine se određuje na osnovu izraza: turbinu. Propelerne karakteristike su date u izveštaju o
3
Ph = ρ gHQ , gde su: ρ (kg/m ) gustina vode u ispitivanju postojeće turbine HE ''Đerdap II''
protočnom traktu, koja se određuje u poglavlju 2.1 za Laboratorije za hidraulične mašine LMH – Lozana,
temperaturu vode Dunava; g = 9,8055 (m/s2); H (m) - Švajcarska [10]. Uzimajući najviše stepene korisnosti za
neto pad turbine. izmerene propelere za padove H r = 6,62m ,
H r = 7 ,36m i H r = 11,77 m određene su vrednosti
2.10 Određivanje hidrauličkog stepena korisnosti koeficijenta K p . Njihove vrednosti su date na Slici 4.
turbine Srednja vrednost koeficijenta protoka je K psr = 337,24 .
Procentualna odstupanja f Kp izmerenih vrednosti K p
Hidraulički stepen korisnosti turbine se definiše kod
cevnih turbina kao odnos unutrašnje snage Pi i od srednje vrednosti K psr su sračunate na osnovu
hidrauličke snage ηh = Pi Ph . Trebalo bi
Ph : f Kp = ( K p − K psr ) ⋅ K psr ⋅100% Najveća procentualna
napomenuti da je u okviru hidrauličkog stepena greška je 2,57%.

VODOPRIVREDA 0350-0519, 38 (2006) 222-224 p. 193


Eksperimentalna hidraulička ispitivanja karakteristika cevne turbine HE "Đerdap II" Miroslav Benišek i saradnici

Kp
360

355 7,36
6,62
350 11,77
344,83
343,98
345

339,52 339,58
340,69
340
338,42
337,36
336,10 336,64 336,42
335 335,36
334,20
332,68
331,21 330,78
330
328,59

325

320
80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 Q400

Slika 4. Koeficijenti protoka Kp određeni INDEX metodom

3 ODREĐIVANJE OPTIMALNE KOMBINATOR- gde su: n-broj merenja u jednoj mernoj seriji i Hi -
SKE ZAVISNOSTI mereni padovi u mernoj seriji.
Da bi se odredile optimalne kombinatorske zavisnosti Sve izračunate veličine protoka Q i stepena korisnosti
( α SA = f (β) pri ηh max za različite parametarske ηh za različite neto padove H i , jedne merne serije,
vrednosti H = const ) izvršena su merenja propelernih svedene su na referentni neto pad H r = const za merene
karakteristika turbine. Pri konstantnim vrednostima
vrednosti otvora radnog kola β i otvora sprovodnog
otvora radnog kola β menjani su otvori sprovodnog
aparata α SA .
aparata α SA tako da bude obuhvaćena i tačka najvišeg
stepena korisnosti. Zavisno od neto pada, vrednosti β
Svedene vrednosti Q p i ηr se određuju na osnovu
uzimane su u intervalu garantovanih karakteristika
turbine: β = −10°;−5°;0°;+5°;+10°;+15°. obrazaca:
∂Q 
Qr = Q + ∆Q = Q +   (H r − H ) (4)
Za svaku vrednost β merene su sve potrebne veličine  ∂H H r
∂η 
date programom. Na osnovu merenih veličina ηr = η + ∆η = η +   (H r − H ) (5)
izračunate su potrebne veličine. Svaka merena veličina, ∂
 H Hr
nakon postizanja stacionarnog stanja, očitavana je

(∂Q ∂H ) i (∂η∂H )
najmanje pet puta za isti merni režim. Na osnovu
računatih veličina izračunate su osrednjene merne gde su: - redom, gradijent
Hr Hr
vrednosti. Objektivno, neto pad prilikom merenja, nije
se mogao održavati konstantnim, te je primenjen protoka i gradijent stepena korisnosti za merenu
postupak svođenja rezultata merenja na isti referentni vrednost α SA = const,β = const u tački H r = const.
pad H r . Za jednu seriju merenja (merenja obavljena pri Vrednosti gradijenata se izračunavaju iz propelernih
približno istom padu) referentni pad je: karakteristika cevne turbine HE ĐERDAP II PRKT-
750-01 koje su dobijene preračunavanjem sa modela na
1 n
n∑
Hr = Hi , (3) original turbinu [6].
i =1

194 VODOPRIVREDA 0350-0519, 38 (2006) 222-224 p.


Miroslav Benišek i saradnici Eksperimentalna hidraulička ispitivanja karakteristika cevne turbine HE "Đerdap II"

Za vrednosti H r = const (tri pada) nacrtani su Iz dobijenihpropelernh i kombinatorskih karakteristika


propelerni dijagrami ηr = f p (Qr ) za β = const . za referentne padove i krivih α SA = f (Q) dobijaju se
Ucrtavanjem obvojnice propelernih krivih ηr = f p (Qr ) optimalni otvori sprovodnog aparata [1]. Odavde slede
dobija se kombinatorna zavisnost ηr = fk (Qr ) , za dati kombinatorske zavisnosti, prikazane na Slici 5, za
pad, a spajanjem tačaka na propelernim krivama konstantne padove H r = 6,62m , H r = 7 ,36m i
α SA = f p (Qr ) , koje odgovaraju tačkama dodira
H r = 11,77m .
obvojnice sa propelerom ηr = f p (Qr ) , dobija se
kombinatorna zavisnost: α SA = fk (Qr ).

β[ ]
ο Измерено МФ
20

15

10 Hr=6,62 m

Hr=7,36 m

Hr=11,77 m
5

-5

-10
25 30 35 40 45 50 55 60 65 70 75
αSA [ο]

Slika 5. Optimalna kombinatorska zavisnost β=f(αSA) za padove Hr=6,62 m, Hr=7,36 m i


Hr =11,77 za agregat br.9 HE "Đerdap II"

Na Slici 6 prikazane su kombinatorske veze: Tabela 3. Kombinatorske zavisnosti agregata br. 9 za


- dobijene merenjem prikazanim u ovom radu, merene padove H r
- dobijene preračunavanjem modelskih ispitivanja u Hr=6,62m Hr=7,36 Hr=11,77m
LMZ, β [°] m
- dobijene preračunavanjem modelskih ispitivanja u αSA [°] αSA [°] αSA [°]
LMH. -10 39,0 37,0 30,0
-5 48,0 45,5 37,0
U Tabeli 3 su date vrednosti kombinatorske zavisnosti
0 55,0 52,0 42,0
β i α SA za merene padove H r = 6,62m , H r = 7 ,36m i
5 61,5 58,5 47,0
H r = 11,77 m . 10 68,0 64,5
15 75 72,5

VODOPRIVREDA 0350-0519, 38 (2006) 222-224 p. 195


Eksperimentalna hidraulička ispitivanja karakteristika cevne turbine HE "Đerdap II" Miroslav Benišek i saradnici

β[ ]
ο Прерачунато са модела ЛМЗ Измерено МФ Прерачунато са модела LMH
20

Hr=7,36 m
15

10 Hr=11,77 m

Hr=6,62 m
5

-5

-10
25 30 35 40 45 50 55 60 65 70 75
ο
αSA [ ]

Slika 6. Uporedne optimalne kombinatorske zavisnosti β=f(αSA) za padove Hr=6,62 m, Hr=7,36 m i Hr =11,77

4 ZAKLJUČAK Svaka pogonska tačka u propelernom režimu merena je


pet puta i uzimane su srednje vrednosti izmerenih
Na osnovu obavljenih merenja i izvršene analize veličina za dalji proračun.
dobijenih rezultata može se zaključiti sledeće:
Koeficijenti protoka Kp su određivani INDEX
Hidraulička ispitivanja turbine su obavljena na
instrumentima koji obezbeđuju visoku tačnost ovih metodom pri čemu su za maksimalne vrednosti stepena
korisnosti propelera uzimane preračunate vrednosti
merenja.
stepena korisnosti na prototip modelskih ispitivanja
izvršenih u LMH [10]. Srednja vrednost koeficijenta
Merenja su obavljena za tri neto srednja pada protoka K psr je određena osrednjavanjem dobijenih
H r = 6,62m , H r = 7 ,36m i H r = 11,77m .
koeficijenata protoka K p određenih za sve izmerene
Prilikom merenja nije bilo moguće održavati konstantan propelere i iznosi K psr = 337,24 . Maksimalna
pad za duži vremenski period te su vrednosti dobijene procentualna greška odstupanja izmerenog K p od
merenjem preračunavane na srednju vrednost pada srednje vrednosti iznosi 2,57%.
postupkom opisanim u poglavlju 3.

196 VODOPRIVREDA 0350-0519, 38 (2006) 222-224 p.


Miroslav Benišek i saradnici Eksperimentalna hidraulička ispitivanja karakteristika cevne turbine HE "Đerdap II"

Kombinatorske veze dobijene merenjem na agregatu br. Hidraulička ispitivanja cevne turbine, Mašinski
9 se dobro slažu sa izmerenim kombinatorskim vezama fakultet, Beograd
u laboratoriji LMH-Lozana [10]. Maksimalno
[4] Bowman A.H., Schoonover. M.R. (1967),
odstupanje iznosi 2o .
Procedure for high precision density
determinations by hydrostatic weight, Journal of
Izmerene snage agregata br. 9 su manje od preračunatih
Research of the National Bureau of Standards,
rezultata modelskih ispitivanja za iste vrednosti otvora
Vol. 71.C, No.3, July 1967, 179-198
lopatica radnog kola i sprovodnog aparata i do 12,5% u
odnosu na rezultate LMH. Ova činjenica postaje jasna [5] Brand L.F. (1984), Die Messeninrichtungen der
kada se uporede izmerene vrednosti protoka u odnosu Hydraulischen Versuchsanstalt “Brunnenmuhle“,
na preračunate rezultate na prototip modelskih Voith Forschung und Konstruktion, Heft 30, auf.
ispitivanja; naime propusna moć (protok) turbine br. 9 7.1
je manji u odnosu na odgovarajuće vrednosti LMH i
LMZ te se za iste padove Hr dobija i manja snaga. [6] Vušković I., Benišek M., Nedeljković M. (1983),
Agregat br. 9 treba da radi sa većim otvorim lopatica Hidrauličke karakteristike cevnih agregata za HE
obrtnog kola i lopaticama sprovodnog aparata po ĐERDAP-II; 5. Protočne propelerne
merenjem utvrđenoj kombinatorskoj vezi da bi ostvario karakteristike i protočna kombinatorska
protoke i snage koje se dobijaju preračunavanjem karakteristika originala cevne turbine HE
modelskih ispitivanja u laboratoriji LMH. “ĐERDAP II“ prečnika radnog kola D1=7,5m za
padove H=1.5-12,5m za radne uslove tV=20˚C i
LITERATURA n=62,5min-1, Mašinski fakultet, Beograd
[7] Chemical Engineering Handbook (1963),
[1] Benišek M., Ignjatović B., Vušković I. (1982),
McGraw-Hill Book Co., New York
Efficiency scale-up for tube turbines at the
operating point of best efficiency and outside the [8] Ignjatović B., Bogdanović S., Benišek M.,
point of best efficiency, Symposium IAHR, 13-17. Albijanić R. (1988), Kompleksna garancijska
September, Amsterdam. ispiivanja cevnih agregata HE “ĐERDAP II“,
LOLA saopštenja, UDK 621.224:627.84/.88., str.
[2] Benišek M., Nedeljković M. i dr. (1989),
4555-4578
Garancijska i kompleksna ispitivanja cevnog
agregata br. 5 u HE “ĐERDAP II“, Hidraulička [9] IEC 60983-191 Field acceptance tests to
ispitivanja cevne turbine, Mašinski fakultet determine the hydraulic performance of hydraulic
Beograd turbines, storage pumps and pump turbines
[3] Benišek M., Božić I., Ilić D., Čantrak Đ. i dr. [10] LMH-EPFL Porcile de Fier II, Bulb Turbines
(2006) Garancijska hidraulička ispitivanja cevne Comparative Model Tests, Final Report No.
turbine agregata br. 9 HE “ĐERDAP II“, 472/473

VODOPRIVREDA 0350-0519, 38 (2006) 222-224 p. 197


Eksperimentalna hidraulička ispitivanja karakteristika cevne turbine HE "Đerdap II" Miroslav Benišek i saradnici

BULB TURBINE HYDRAULIC TESTS AT THE HPP “ĐERDAP II“

by

Prof. dr Miroslav BENIŠEK, Ivan BOŽIĆ, Dejan ILIĆ, Đorđe ČANTRAK


Faculty of Mechanican Engineering, University of Belgrade

Summary

The authors present some results of the bulb turbine performed at three different average heads: Hr = 6,62 m,
complex commissioning tests of the unit No 9 at the Hr = 7,36 m and Hr = 11,77 m.
additional HPP “Đerdap II”. The conditions under
which the tests were performed are described. A brief Key words: HPS, bulb hydrualic turbine, hydraulics,
analysis of the results is also given. Tests were measurements.

Redigovano 19.12.2006.

198 VODOPRIVREDA 0350-0519, 38 (2006) 222-224 p.