EPC RELOKASI FLARE

BPP-II DAN NEW FLARE HCC


RDMP RU V - BALIKPAPAN
KSO ADHI - REKIND
DOCUMENT NUMBER REV. : 002
SECTION IV
PAGE
26072-203-P9C-P70-G0003 (PIPE 66" SPOOL TO TIE IN FLARE HEADER)
4 of 4

Data Input Stored Energy Calculation

Pipe Data Energy (E)


OD Pipe 66 In = 1,6764 m
Thk 0,5 In = 12,7 mm
ID Pipe 65 In = 1,651 m ##
Length 2 m
Result 1.996.964 Joule
Volume (V) 4,28 m3
Test Medium Air
Conversion to TNT
Process Data
Design Press. 3,5 Kg/cm2g : 343233 Pag
Test Press. (Pat ) 4,85 Kg/cm2a : 475623 Pa
Atm Press. (Pa ) 101000 Pa
Result 0,47 Kg

BLAST ZONE RADIUS

Formula R scaled = 20 m/kg1/3

Any value below 20 m/kg1/3 considered unsafe

R = 20 Meter

SUMMARY

Base on calculation above, the minimum distance between personnel and pipe being tested during
pneumatic is set to 30 meters (Minimum distance base on Code), Below this minimum distance if
something goes wrong to the pipe, the blast may cause injury to the personel nearby.