Download as pdf or txt
Download as pdf or txt
You are on page 1of 13

Training Manual

A 318

ATA 38
Water & Waste
Diff. to A 320
ATA 104 L3

Lufthansa
Technical Training GmbH For Training Purposes Only
Book No: A318 38 Diff L3 Lufthansa Base  Lufthansa 1995
For training purposes and internal use only.
Copyright by Lufthansa Technical Training GmbH.
All rights reserved. No parts of this training
manual may be sold or reproduced in any form
without permission of:

Lufthansa Technical Training GmbH

Lufthansa Base Frankfurt


D-60546 Frankfurt/Main
Tel. +49 69 / 696 41 78
Fax +49 69 / 696 63 84

Lufthansa Base Hamburg


Weg beim Jäger 193
D-22335 Hamburg
Tel. +49 40 / 5070 24 13
Fax +49 40 / 5070 47 46
Lufthansa Technical Training
WATER & WASTE A318
WASTE DISPOSAL
38

ATA 38: WATER & WASTE


For Training Purposes Only

FRA US/T5 SeG 17.09.2003 Page: 1


Lufthansa Technical Training
WATER & WASTE A318
WASTE DISPOSAL
38−31

TOILET SYSTEM
TOILETSYSTEMDIFFERENCES BETWEEN THE A320 AND THE A318
On the A320, the Vacuum System Controller ( VSC ) controls and monitors the
vacuum system and sends information directly to the Forward Attendant Panel.
The VSC interfaces with other aircraft systems.
On the A318, the VSC function is integrated into the Cabinntercommunication
Data System ( CIDS ) director, the altitude data come from Cabin Pressure
Controller ( CPC ) via the System Data Acquisition Concentrator ( SDAC ).
Door switch information is send to the CIDS director via Decoder / Encoder
Unit ( DEU ) B.

A new Flight Attendant Panel ( FAP ) displays information.

SYSTEM DESCRIPTION AND OPERATION


Waste system data is received by DEU−Bs and sent to the CIDS directors.
This system is controlled by the Vacuum System Controller Function ( VSCF )
which is integrated inside the CIDS director.
The user interface and system display is on the FAP.
For Training Purposes Only

US / F gs 11.07. 96 Page: 2
Lufthansa Technical Training
WATER & WASTE A318
WASTE DISPOSAL
38−31

DEU B DEU B

DEU B

TO FWD LAVATORY FCU FLUSH SWITCH


AND GALLEY SYSTEM TOILET ASSY

2 LGCIU
FROM POTABLE
WATER SYSTEM
FROM / TO CIDS SDAC
FWD ATTENDANT PANEL DIRECTOR 1 RINSE
CFDIU VALVE

FLUSH VALVE
CABIN FLOOR

WATER SEPARATOR
VACUUM GENERATOR 37 MG

LQ. LEV. SENSOR

WASTE HOLDING TANK


LEGENDE : 3300 MM

VACUUM WASTE LINE


For Training Purposes Only

FLUSHING LINE WASTE TANK

VACUUM LINE LIQUIDE LEVEL


TRANSMITTER 40 MG
A P COMPENSATOR LINE
WASTE DRAIN
TOILET WASTE LINE VALVE 3340
TOILET SERVICE PANEL

POTABLE WATER LINE


44 MG
RINSE CONNECTION LEVER CONTROL
UNIT 3344MM

Figure 1 Toilet System Schematic


US / F gs 11.07. 96 Page: 3
Lufthansa Technical Training
WATER & WASTE A318
POTABLE
38−10

WATER SYSTEM
POTABLE WATER SYSTEM DIFFERENCES BETWEEN THE A319
AND THE A318
The main difference between the A319 and the A318 potable water systems is
in the quantity indication. The A319 potable water quantity transmitter goes
directly to the Forward Attendant Panel.
On the A318, the water quantity transmitter sends the information to a Decoder
Encoder Unit ( DEU ) B which in turn interfaces with the active Cabin
Intercommunication Data System ( CIDS ) director. Potable water quantity is
displayed on the new Flight Attendant Panel ( FAP ).
The service door OPEN information is still sent to the FAP, but through a DEU
B and the active CIDS director.
For Training Purposes Only

US/T SeG SEP.03 Page: 4


Lufthansa Technical Training
WATER & WASTE A318
POTABLE
38−10

FROM / TO CIDS DEU B


FWD ATTENDANT PANEL DIRECTOR 1

CABIN FLOOR
TO FWD LAVATORY
DIR2 PRESSURE FROM
AND GALLEY BLEED AIR SYST. TO AFT
LAVATORIES
TO FCU & C/R PANEL REGULATOR and GALLEY

LEGENDE: POTABLE WATER TANK


3000 MM
ELECTRIC WIRING
PORTABLE WATER LINE
AIR LINE
INSULATED AND HEATED
INSULATED
SHROUDED WATER LINE
M
FILL / OVERFLOW
DRAIN VALVE 8 MA
For Training Purposes Only

DRAIN VALVE 4 MP M

FWD DRAIN PANEL WATER SERVICE PANEL 2023 VU

QTY
GRD AIR PRESS. INDICATOR
DRAIN FULL
OVERFLOW INDICATOR
CABLE FILL / DRAIN VALVE POS.
CONTROL
CABLE CONTROL DRAIN POS. SWITCH 3MP

Figure 2 Potable Water System Basic Schematic


US/T SeG SEP.03 Page: 5
Lufthansa Technical Training
LANDING GEAR A318
WHEELS AND BRAKES
32−40

TOILET SYSTEM

FAP WATER/WASTE PAGE


The FAP WATER / WASTE page appears by selecting the dedicated key on
the tool bar.
It can also appear automatically when the water service door is open or when
there is a fault in the system. This page gives information about the water and
waste system.
The WATER / WASTE page has:
− On the aircraft symbol, the location of the lavatory is shown either activated
with a gray square or de−activated with an amber square and its associated
name. A lavatory is de−activated when the Flush Control Unit is inoperative.
An amber cross is displayed on the square in case of no communication with
the Flush Control Unit.
− A messages list box will be shown, if there are any messages for the water/
waste system.
− A potable water tank and a waste water tank symbol, which also display
liquid level as a percentage.
− A RESET WARN pushbutton to be used in the case of a rinse valve
failure. All visual warnings are reset by this button ( ACP, AIP, and LAV CALL
LIGHT).
For Training Purposes Only

FRA US-T SeG 17.09.03 Page: 6


Lufthansa Technical Training
LANDING GEAR A318
WHEELS AND BRAKES
32−40

FAP Water / Waste Page

CAUT
WATER / WASTE SELECTED
QUANTITY
WASTE QUANTITY WATER QUANTITY
FLUSH
CYCLE
100 100 50 %
AKTIVE

75 75
LAV A
Water
50 50
Heater
on De- +
press

25 25 Reset Pre
Warn. Select

0 0

MESSAGE DATE. TIME

CHECK LAVATORY:
LAV A
Prev
Page
For Training Purposes Only

Next
Page

Screen Water/ System Cabin


off Audio Lights Doors Temp Smoke Status
Waste Info

Figure 3 Water / Waste Page


FRA US-T SeG 17.09.03 Page: 7
Lufthansa Technical Training
WATER & WASTE A318
WASTE DISPOSAL
38−30

TOILET SYSTEM
MCDU TOILET PAGES

Selecting TOILET line key on the SYSTEM REPORT/TEST page does not
give access to the TOILET SYSTEM page anymore.

That gives access to the CIDS 1 ( or 2 ) TOILET SYStem page.


Available information is almost the same.
The LRU IDENTIFICATION page shows the CIDS director identification.
The new STATUS page displays the status of the toilet system.
For Training Purposes Only

FRA US-T SeG 17.09.03 Page: 8


Lufthansa Technical Training
WATER & WASTE A318
WASTE DISPOSAL
38−30

SYSTEM REPORT / TEST


< PNEU ENG >

< APU TOILET >

< RETURN

NEXT CIDS1−TOILET SYS


CIDS1−TOILET SYS 1/2 CIDS1−TOILET SYS 2/2 SYSTEM STATUS
PAGE LAST LEG CLASS 3
<REPORT FAULTS> WASTE SVCE PNL : CLOSED
VSC FUNCTION IS LIQD LVL XMTR : 1%
PREVIOUS LEGS LIQD LVL SNSR : FAIL
INTEGRATED IN
<REPORT
VACU GENERATOR: ENABLE
CIDS DIRECTOR VACU GEN OVEHT : NO
101RH & 102RH <LRU IDENT VACU GEN REL : OFF
GEN PWR SPLY : ON
CALLED 1 SYS PWR SPLY : ON
CIDS-TOILET SYS GRD STS : GRD DEPRESS: XXX
TROUBLE SHOOT GROUND SVCE : NO DELTA P: XXX
<DATA REPORT>

< RETURN < RETURN STATUS> < RETURN PRINT *

CIDS1−TOILET SYS
LRU IDENTIFICATION
For Training Purposes Only

CIDS DIR FIN: XXXXXXX


PN:XXXXXXX
SN:XXXXX

< RETURN PRINT *

Figure 4 MCDU TOILET Page


FRA US-T SeG 17.09.03 Page: 9
A318 38 Diff L3

TABLE OF CONTENTS
ATA 38: WATER & WASTE . . . . . . . . . . . . . . . . . . . . 1
TOILET SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
WATER SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
TOILET SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
TOILET SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

FRA US/T-5 Jacobi Oct 2003


Page i
A318 38 Diff L3

TABLE OF FIGURES
Figure 1 Toilet System Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Figure 2 Potable Water System Basic Schematic . . . . . . . . . . . . . . 5
Figure 3 Water / Waste Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Figure 4 MCDU TOILET Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

FRA US/T-5 Jacobi Oct 2003


Page ii

You might also like