Download as pdf or txt
Download as pdf or txt
You are on page 1of 73

Pos.

14
Hydrokraft Piston
Pump - PVW_2016
Eaton®
Hydrokraft Open Loop Piston Pumps W Series
Contents

Introduction General Dimensions + Shaft & Mounting Options


Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Variable Displacement PVW
Typical Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 130 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Model Codes 180 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Basic Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 250 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
DF Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 360 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
LR Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 500 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
SP Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 750 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
DP Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Control Options
PQ Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 DF & LR Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
ES Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 SP Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
No Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 DP Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Combination Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 PQ Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Form Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 ES Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Pump Specifications General Dimensions + Shaft & Mounting Options
Metric . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Fixed Displacement PFW
US . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 250 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Performance Curves 360 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
130 & 180 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 500 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
250 & 360 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 750 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
500 & 750 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Thru-Drive Options
Installation and Start-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 130 & 180 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
250 & 360 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Application Data and Fluid Recommendations . . . . . . . . . . . . . 21
500 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
750 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Swash Angle & Flow Direction . . . . . . . . . . . . . . . . . . . . . . . . . . 70

2 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Introduction

• Axial piston pumps with • Rotating and pressure-loaded • Modular design gives these Available Displacement Sizes
swash plate design for parts are pressure balanced. pumps a wide range of
130 cm3 (8.0 in3/rev)
reliable operation and long • Through-drive enables applications.
3
life. multiple pump installations • Fast response times. 180 cm (11.0 in3/rev)
3
• Pressure up to 420 bar. from a single shaft. Multiple 250 cm (15.0 in3/rev)
• Rated speed up to 1800 rev/ pump combinations are also 360 cm3 (22.0 in3/rev)
min. Higher speeds possible. available.
3
500 cm (30.5 in3/rev)
• Oversize shafts and bearings. • Integrated pilot pump, filter
3
and pressure relief valves 750 cm (45.0 in3/rev)
available.

Displacement Controls Typical Section of Open Loop PVW Pump


DF - Pressure compensator
controlled
LR - Power control with pressure
limiter Control

SP - Displacement proportional
to electric signal
Control Piston
DP - Displacement proportional
to pressure signal

PQ - Digital controller Swash Angle


Sensor Indicator
ES - Displacement adjustment
via electric motor
Extra functions available
for DP & SP:
Pressure limitation and/or power
control overriding function.

Note
Thru-Drive
Swash Option
Dimensional data provided in Plate
this catalog is subject to change Cylinder Valve
without notice. Block Plate
Shaft Piston

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 3
● Preferred standard option
Model Code ● Other standard option
● Special option on request
Open Loop Pumps ✕ Not available
W Series - Basic Pumps

P *W* – * * *M* * * * * * 1 R * * S * * * #
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Pump Size 130 180 250 360 500 750 Pump Size 130 180 250 360 500 750
1 Pump Maximum Displacement Screws (cont.)
P – Open loop pump ● ● ● ● ● ● 6 – Fixed mech. stop ring sides A & B ● ● ● ● ● ●

2 Displacement Note: Customer adjustment required


4 used as max. volume adjustment side A
F – Fixed ✕ ✕ ● ● ● ●
5 used as min. volume stop side A
V – Variable ● ● ● ● ● ●
14 15 Thru-Drive Options
3 Pump Series
00 – None ● ● ● ● ● ●
W – “W” series (ex-30 design) ● ● ● ● ● ●
0A – SAE A ● ● ● ● ● ●

4 Configuration 0B – SAE B ● ● ● ● ● ●

S – Single unit ● ● ● ● ● ● 0C – SAE C ● ● ● ● ● ●

F – Front unit ● ● ● ● ● ● 0P – Pilot pump (8 cm3/rev) ● ● ● ● ● ●

M – Middle unit ● ● ● ● ● ● 0* – * assigned by Engineering ● ● ● ● ● ●

R – Rear unit ● ● ● ● ● ●
16 Main Ports
5 Separator ● ● ● ● ● ●
1 – SAE ports - Metric bolts ● ● ● ● ● ●

6 7 8 Displacement cm3/rev (in3/rev) 17 Main Port Orientation


130 – 130 cm3/rev (8 in3/rev) ● ✕ ✕ ✕ ✕ ✕
R – Radial (side ports) ● ● ● ● ● ●

180 – 180 cm3/rev (11 in3/rev) ✕ ● ✕ ✕ ✕ ✕


A – Axial (rear ports) ✕ ✕ ● ✕ ● ●

250 – 250 cm3/rev (15.3 in3/rev) ✕ ✕ ● ✕ ✕ ✕


18 19 Main Drive Shaft End
360 – 360 cm3/rev (22.0 in3/rev) ✕ ✕ ✕ ● ✕ ✕

500 – 500 cm3/rev (30.5 in3/rev) ✕ ✕ ✕ ✕ ● ✕ 01 – ISO straight key ● ● ● ● ● ✕

750 – 750 cm3/rev (45.8 in3/rev) ✕ ✕ ✕ ✕ ✕ ● 02 – ISO splines ● ● ● ● ● ●

05 – ISO special splines ● ● ● ● ● ✕


*** – Non-standard (PFW only) ◆ ✕ ✕ ● ● ● ●

◆ Non-standard displacements (cm3/rev): D1 – SAE D keyed 13/4" ● ● ✕ ✕ ✕ ✕

250 220/200 D2 – SAE D splined 8/16 13T ● ● ✕ ✕ ✕ ✕

360 E1 – SAE E keyed 13/4" ✕ ✕ ● ● ✕ ✕


310
500 E2 – SAE E splined 8/16 13T ✕ ✕ ● ● ✕ ✕
465/365 F1 – SAE F keyed 2" ✕ ✕ ● ● ✕ ✕
750 710 F2 – SAE F splines 8/16 15T ✕ ✕ ● ● ✕ ✕

9 Basic Standard 20 Drive Shaft Seal Configuration


M – Metric ● ● ● ● ● ●
S – Single shaft seal ● ● ● ● ● ●
10 11 Mounting Flange
21 Seal Material
05 – ISO 3019/2-160B4HW ● ● ✕ ✕ ✕ ✕

07 – ISO 3019/2-200B4HW ✕ ✕ ● ● ✕ ✕
V – FKM ● ● ● ● ● ●

08 – ISO 3019/2 8 bolt metric ✕ ✕ ✕ ✕ ● ●


C – Special shaft seal, for HFC fluids ● ● ● ● ● ●

09 – Special 8-bolt flange ✕ ✕ ✕ ✕ ● ✕


F – FKM + front bearing flushing prepared ● ● ● ● ● ●

0D – SAE D 4-hole flange ● ● ✕ ✕ ✕ ✕


K – FKM with HP lubrication ● ● ● ● ● ●

0E – SAE E 4-hole flange ✕ ✕ ● ● ✕ ✕ 22 Yoke Position Indicator


0F – SAE F 4-hole flange ✕ ✕ ● ● ✕ ✕
0 – No position indicator ● ● ● ● ● ●

12 Rotation V – Visual indicator ❍ ❍ ❍ ❍ ❍ ❍

R – Clockwise ● ● ● ● ● ● P – Voltage indicator ● ● ● ● ● ●

L – Counter-clockwise ● ● ● ● ● ● M – Voltage + visual indicator ❍ ❍ ❍ ❍ ❍ ❍

R – Current indicator ● ● ● ● ● ●
13 Maximum Displacement Screws S – Current + visual indicator ● ● ● ● ● ●

0 – Displacement adjusting screw Other options on request.


With control DF/LR ● ● ● ● ● ●

With control DP/SP/PQ ✕ ✕ ● ● ● ✕


23 Surface Coating
With control DP or SP + DF ✕ ✕ ● ● ● ✕ A – Primer blue ▼ ● ● ● ● ● ●

With control DP or SP (+ DF) + LR/ES ✕ ✕ ✕ ✕ ✕ ✕ 0 – Rust inhibitor oil ● ● ● ● ● ●

4 – Fixed mechanical stop ring side A ● ● ● ● ● ● ▼ Other finishes on request.


5 – Fixed mechanical stop ring side B ● ● ● ● ● ●
24 Control Model Code
Continued next column
Pump Size 130 180 250 360 500 750 See fields 24 to 48 on following pages.
Pump Size 130 180 250 360 500 750

4 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
● Preferred standard option
Model Code ● Other standard option
● Special option on request
Open Loop Pumps ✕ Not available
W Series - DF Control

D F 0 0 0 A * * 0 0 0 0 * 0 0 * * * * * * * * * *
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

Pump Size 130 180 250 360 500 750 Pump Size 130 180 250 360 500 750
24 25 Control Type 39 Control Voltage
DF – Pressure compensator ● ● ● ● ● ● 0 – Not applicable ● ● ● ● ● ●

26 Displacement Adjustment Options B – 110V AC 50 Hz / 120V AC 60 Hz ● ● ● ● ● ●

D – 220V AC 50 Hz / 240V AC 60 Hz ● ● ● ● ● ●
0 – Not applicable G – 12V DC ● ● ● ● ● ●

27 28 Electronic Controls H – 24V DC (preferred voltage) ● ● ● ● ● ●

0 – Not applicable 40 41
Customer Adjustment Specification
29 Yoke Displacement Zone 42 43
A – Single side of centre “A” ● ● ● ● ● ● 0000 – None ● ● ● ● ● ●

30 Additional Functions **** – Eaton assigned number as per ● ● ● ● ● ●

data specified in table below ◆


0 – None ● ● ● ● ● ●
44 45 46 Special Features
1 – Load sensing (standard Δp = 15 bar) ● ● ● ● ● ●

A – 2-level pressure compensator, ● ● ● ● ● ● 000 – None ● ● ● ● ● ●

4/2 solenoid valve *** – Defined by Eaton ● ● ● ● ● ●

B – 2-level pressure compensator, ● ● ● ● ● ● 47 48 Design Number


4/3 solenoid valve – 10-99 assigned by Eaton ● ● ● ● ● ●
**
31 Pressure Control Options Pump Size 130 180 250 360 500 750
0 – None i.e. pilot operated with remote ● ● ● ● ● ●

port (standard arrangement)


F – Remote port without pilot valve ● ● ● ● ● ●

K – Electro-proportional relief valve, ● ● ● ● ● ●

complete with electronic card


S – Slow upstroke screw adjustment ● ● ● ● ● ●

32 33 34 Power Control ◆ Example for Customer Adjustment Specifications


000 – Not applicable Special Pressure Main Stage Pilot Valve Load Sense Δp
Adjustment Pressure Control Pressure Control
35 Pilot Oil Filter
Standard setting (bar) 20 90 15
0 – Not applicable
Max. setting (bar) 40 350 40
36 Venting Valve Customer-specified
0 – None ● ● ● ● ● ● adjustment (bar) ....... ....... .......
1 – Solenoid valve ▲ ● ● ● ● ● ●
Note: Setting must be at least 30 bar.
▲ Specify voltage in 39 Special Max. Minimum Maximum
37 Position Monitoring Displ. Adjustment Displacement Displacement
Standard 0 cm3/rev 100%
0 – None
Customer-specified
38 Electric Motor Type adjustment (cm3/rev) ....... .......
0 – None Note: Special pressure adjustments and/or maximum displacment adjustments are the
Pump Size 130 180 250 360 500 750 most common reasons for using this option.

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 5
● Preferred standard option
Model Code ● Other standard option
● Special option on request
Open Loop Pumps ✕ Not available
W Series - LR Control

L R 0 0 0 A * * * * * 0 * 0 0 * * * * * * * * * *
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

Pump Size 130 180 250 360 500 750 Pump Size 130 180 250 360 500 750
24 25 Control Type 39 Control Voltage
LR – Power control ● ● ● ● ● ● 0 – Not applicable ● ● ● ● ● ●

26 Displacement Adjustment Options B – 110V AC 50 Hz / 120V AC 60 Hz ● ● ● ● ● ●

D – 220V AC 50 Hz / 240V AC 60 Hz ● ● ● ● ● ●
0 – Not applicable G – 12V DC ● ● ● ● ● ●

27 28 Electronic Controls H – 24V DC ● ● ● ● ● ●

0 – Not applicable 40 41
Customer Adjustment Specification
29 Yoke Displacement Zone 42 43
A – Single side of centre “A” ● ● ● ● ● ● 0000 – None ● ● ● ● ● ●

30 Additional Functions **** – Eaton assigned number as per ● ● ● ● ● ●

data specified in table below ◆


2 – Pressure limiter ● ● ● ● ● ●
44 45 46 Special Features
3 – Load sensing and pressure limiter ● ● ● ● ● ●

(standard Δp = 15 bar) ▲ 000 – None ● ● ● ● ● ●

▲ To select Power Control without Pressure *** – Defined by Eaton ● ● ● ● ● ●

Limiter, specify ... LR ... A2F. 47 48 Design Number


31 Pressure Control Options ** – 10-99 assigned by Eaton ● ● ● ● ● ●

0 – None i.e. pilot operated with remote ● ● ● ● ● ● Pump Size 130 180 250 360 500 750
port (standard arrangement)
F – Remote port without pilot valve ● ● ● ● ● ●

K – Electro-proportional relief valve, ● ● ● ● ● ●

complete with electronic card


S – Slow upstroke screw adjustment ● ● ● ● ● ●
◆ Example for Customer Adjustment Specifications
32 33 34 Power Control Specification Special Pressure Main Stage Pilot Valve Load Sense Δp
*** – 3-digit value in kW at 1500 rev/min ● ● ● ● ● ● Adjustment Pressure Control Pressure Control
35 Pilot Oil Filter Standard setting (bar) 20 90 15
Max. setting (bar) 40 350 40
0 – Not applicable
Customer-specified
36 Unloading Valve adjustment (bar) ....... ....... .......
0 – None ● ● ● ● ● ● Note: Setting must be at least 30 bar.
1 – Solenoid valve ▼ ● ● ● ● ● ●
Special Max. Minimum Maximum
▼ Specify voltage in 39 Displ. Adjustment Displacement Displacement
37 Position Monitoring Standard 0 cm3/rev 100%
Customer-specified
0 – Not applicable
adjustment (cm3/rev) ....... .......
38 Electric Motor Type Note: Special pressure adjustments and/or maximum displacment adjustments are the
0 – Not applicable most common reasons for using this option.
Pump Size 130 180 250 360 500 750

6 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
● Preferred standard option
Model Code ● Other standard option
● Special option on request
Open Loop Pumps ✕ Not available
W Series - SP Control
22 = P, M, R or S mandatory
(electrical yoke position indicator)

S P * * * A * * * * * * 0 0 0 0 * * * * * * * * *
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

Pump Size 130 180 250 360 500 750 Pump Size 130 180 250 360 500 750
24 25 Control Type 37 Position Monitoring
SP – Displacement adjustment via ● ● ● ● ● ● 0 – Not applicable
proportional valve 38 Electric Motor Type
26 Displacement Adjustment Options 0 – Not applicable
A – CETOP 3 interface only ● ● ● ● ● ●
39 Venting Valve Control Voltage
B – CETOP 5 interface only ● ● ● ● ● ●

C – CETOP 3 proportional valve KDG4V-3 ● ● ● ● ● ●


0 – Not applicable
D – CETOP 3 proportional valve ● ● ● ● ● ● 40 41
Customer Adjustment Specification
KBSDG4V-3 with OBE 42 43
E – CETOP 5 proportional valve ● ● ● ● ● ●
0000 – None ● ● ● ● ● ●

KBSDG4V-5 with OBE **** – Eaton assigned number as per ● ● ● ● ● ●

F – CETOP 5 servo-valve ● ● ● ● ● ●
data specified in table below ◆
27 28 Electronic Amplifier Control 44 45 46 Special Features
03 – ER 9.3-10 ▲ ● ● ● ● ● ●
000 – None ● ● ● ● ● ●

04 – ER 9.4-10 (CETOP 3) servo ● ● ● ● ● ●


*** – Defined by Eaton ● ● ● ● ● ●

00 – No amplifier card ● ● ● ● ● ●
47 48 Design Number
▲ Amplifier card required for 26 = C, D, E
** – 10-99 assigned by Eaton ● ● ● ● ● ●

29 Yoke Displacement Zone Pump Size 130 180 250 360 500 750
A – Single side of centre “A” ● ● ● ● ● ●

30 Additional Functions
0 – None ● ● ● ● ● ●

4 – Pressure limiter override ● ● ● ● ● ●

5 – Pressure limiter and ● ● ● ● ● ●

power limiter override


31 Pressure Control Options
0 – None i.e. pilot operated with remote ● ● ● ● ● ● ◆ Example for Customer Adjustment Specifications
port (standard arrangement) Special Pressure Main Stage Pilot Valve Load Sense Δp
F – Remote port without pilot valve ● ● ● ● ● ● Adjustment Pressure Control Pressure Control
K – Electro-proportional relief valve, ● ● ● ● ● ● Standard setting (bar) 20 90 15
complete with electronic card Max. setting (bar) 40 350 40
32 33 34 Power Control Specification Customer-specified
adjustment (bar) ....... ....... .......
*** – 3-digit value in kW at 1500 rev/min ● ● ● ● ● ●

Note If no power limiter override: 000 Note: Setting must be at least 30 bar.
Special Max. Minimum Maximum
35 Pilot Oil Filter
Displ. Adjustment Displacement Displacement
0 – None ● ● ● ● ● ●
Standard 0 cm3/rev 100%
V – Filter with visual indicator ● ● ● ● ● ●
Customer-specified
E – Filter with electrical indicator ● ● ● ● ● ●
adjustment (cm3/rev) ....... .......
36 Venting Valve
Note: Special pressure adjustments and/or maximum displacment adjustments are the
0 – Not applicable most common reasons for using this option.
Pump Size 130 180 250 360 500 750

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 7
● Preferred standard option
Model Code ● Other standard option
● Special option on request
Open Loop Pumps ✕ Not available
W Series - DP Control

DP * 0 0 A * * * * * * 0 0 0 0 * * * * * * * * *
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

Pump Size 130 180 250 360 500 750 Pump Size 130 180 250 360 500 750
24 25 Control Type 38 Electric Motor Type
DP – Displacement adjustment ● ● ● ● ● ● 0 – Not applicable
proportional to pilot pressure 39 Venting Valve Control Voltage
26 Displacement Adjustment Options 0 – Not applicable
G – CETOP 3 interface only ● ● ● ● ● ●
40 41
H – Remote port G1/4" ● ● ● ● ● ● Customer Adjustment Specification
42 43
J – Proportional KCG relief valve ● ● ● ● ● ●

including EEA-PAM amplifier card 0000 – None (standard) ● ● ● ● ● ●


**** – Eaton assigned number as per ● ● ● ● ● ●
27 28 Control Electronics data specified in table below ◆
00 – Not applicable 44 45 46 Special Features
29 Yoke Displacement Zone 000 – None ● ● ● ● ● ●

A – Single side of centre “A” ● ● ● ● ● ●


*** – Defined by Eaton ● ● ● ● ● ●

30 Additional Functions 47 48 Design Number


0 – None ● ● ● ● ● ●
** – 10-99 assigned by Eaton ● ● ● ● ● ●

4 – Pressure limiter override ● ● ● ● ● ●


Pump Size 130 180 250 360 500 750
5 – Pressure limiter and ● ● ● ● ● ●

power limiter override


31 Pressure Control Options
0 – None i.e. pilot operated with remote ● ● ● ● ● ●

port (standard arrangement)


F – Remote port without pilot valve ● ● ● ● ● ●
◆ Example for Customer Adjustment Specifications
K – Electro-proportional relief valve, ● ● ● ● ● ●
Special Pressure Main Stage Pilot Valve Load Sense Δp
complete with electronic card Adjustment Pressure Control Pressure Control
32 33 34 Power Control Specification Standard setting (bar) 20 90 15
*** – 3-digit value in kW at 1500 rev/min ● ● ● ● ● ● Max. setting (bar) 40 350 40
Note If no power limiter override: 000 Customer-specified
35 Pilot Oil Filter adjustment (bar) ....... ....... .......
Note: Setting must be at least 30 bar.
0 – None ● ● ● ● ● ●

V In-line filter with visual indicator ● ● ● ● ● ● Special Max. Minimum Maximum


E In-line filter with electrical indicator ● ● ● ● ● ● Displ. Adjustment Displacement Displacement
36 Venting Valve Standard 0 cm3/rev 100%
Customer-specified
0 – Not applicable
adjustment (cm3/rev) ....... .......
37 Position Monitoring Note: Special pressure adjustments and/or maximum displacment adjustments are the
0 – Not applicable most common reasons for using this option.
Pump Size 130 180 250 360 500 750

8 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
● Preferred standard option
Model Code ● Other standard option
● Special option on request
Open Loop Pumps ✕ Not available
W Series - PQ Control
22 = P, M, R or S mandatory
(electrical yoke position indicator)

PQ * 00 * 0 0 000000 0 0 0 0 0 ****
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46

Pump Size 130 180 250 360 500 750 Pump Size 130 180 250 360 500 750
24 25 Control Type 40 Position Monitoring
PQ – Proportional valve multifunctional ● ● ● ● ● ● 0 – Not applicable
control (PpQ controller) 41 Electric Motor Type
26 Displacement Adjustment Options 0 – Not required for this control type ● ● ● ● ● ●

D – CETOP 3 proportional valve + OBE ● ● ● ● ● ●


42 Failsafe Valve Control Voltage
E – CETOP 5 proportional valve + OBE ● ● ● ● ● ●
0 – Not applicable
27 28 Control Electronic
43 44
00 – Without electronics ● ● ● ● ● ● Customer Adjustment Specification
45 46
(to be ordered separately)
0000 – None ● ● ● ● ● ●
29 Yoke Displacement Zone
**** – Eaton assigned number as per ● ● ● ● ● ●

A – No pressure sensor one side ▲ ● ● ● ● ● ● data specified in table below ◆


C No pressure sensor either side ▲ ● ● ● ● ● ● Pump Size 130 180 250 360 500 750
D Pressure sensor 4-20 mA one side ● ● ● ● ● ●

E Pressure sensor 4-20 mA both sides ● ● ● ● ● ●

▲ Without pressure sensor but with G1/2"


thread to fit user-provided pressure sensor.
30 Additional Functions
0 – Not required ● ● ● ● ● ●

31 Pressure Control Options


0 – Not required for this control type ● ● ● ● ● ●

32 33 34
Power Control Specification
35 36 37
000 – Not applicable for this control type
000 ◆ Example for Customer Adjustment Specifications
Special Max. Minimum Maximum
38 Pilot Oil Filter
Displ. Adjustment Displacement Displacement
0 – No filter (standard) ● ● ● ● ● ●
Standard 0 cm3/rev 100%
39 Failsafe Valve Customer-specified
0 – Not applicable adjustment (cm3/rev) ....... .......
Note: Not required, integrated in proportional Note: Special pressure adjustments and/or maximum displacment adjustments are the
valve with OBE. most common reasons for using this option.
Pump Size 130 180 250 360 500 750

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 9
● Preferred standard option
Model Code ● Other standard option
● Special option on request
Open Loop Pumps ✕ Not available
W Series - ES Control
Available to special order only

E S * 0 0 A 0 0 0 0 0 0 0 * * 0 * * * * * * * * *
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

Pump Size 130 180 250 360 500 750 Pump Size 130 180 250 360 500 750
24 25 Control Type 39 Venting Valve Control Voltage
ES – Displacement adjustment ● ● ● ● ● ● 0 – Not applicable
via electric motor 40 41
Customer Adjustment Specification
26 Displacement Adjustment Options 42 43
M – Electric motor, fast response ● ● ● ● ● ● 0000 – None (standard) ● ● ● ● ● ●
N – Electric motor, medium response ● ● ● ● ● ●
**** – Eaton assigned number as per ● ● ● ● ● ●
P – Electric motor, slow response ● ● ● ● ● ● data specified in table below ◆
27 28 Control Electronics 44 45 46 Special Features
00 – Not applicable 000 – None ● ● ● ● ● ●

29 Yoke Displacement Zone *** – Defined by Eaton ● ● ● ● ● ●

A – Single side of centre “A” ● ● ● ● ● ●


47 48 Design Number
30 Additional Functions ** – 10-99 assigned by Eaton ● ● ● ● ● ●

Pump Size 130 180 250 360 500 750


0 – Not applicable
31 Pressure Control Options
0 – Not applicable
32 33 34 Power Control Specification
000 – Not applicable
35 Pilot Oil Filter
0 – Not applicable
36 Venting Valve
0 – Not applicable
37 Position Monitoring ◆ Example for Customer Adjustment Specifications
A – 4 limit switches ● ● ● ● ● ●
Special Maximum Minimum Maximum
B – 8 limit switches ● ● ● ● ● ●
Displacement Adjustment Displacement Displacement
P – 4 limit switches with sensor ● ● ● ● ● ●
Standard 0 cm3/rev 100%
T – 8 limit switches with sensor ● ● ● ● ● ●
Customer-specified adjustment (cm3/rev)
38 Electric Motor Type ....... .......
2 – Motor with brake (IP54) ● ● ● ● ● ●
Note: Special response times (see table in ES section of Control Options) and/or
3 – Motor without brake (explosion-proof) ● ● ● ● ● ●
maximum displacment adjustments are the most common reasons for using this option.
Pump Size 130 180 250 360 500 750

10 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
● Preferred standard option
Model Code ● Other standard option
● Special option on request
Open Loop Pumps ✕ Not available
W Series - No control: 2 =F
Fixed Displacement PFW Models

0 0 0 0 0 A 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * * * * *
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

Pump Size 130 180 250 360 500 750 Pump Size 130 180 250 360 500 750
24 25 Control Type 36 Bypass/Venting Valve
00 – No control (PFW only, not available on ● ● ● ●
0 – Not applicable
sizes 130 & 180) 37 Position Monitoring
26 Displacement Adjustment Options 0 – Not applicable
0 – Not applicable 38 Electric Motor Type
27 28 Control Electronics 0 – Not applicable
0 – Not applicable 39 Control Voltage
29 Yoke Displacement Zone 0 – Not applicable
A – Single side of centre “A” ● ● ● ●
40 41
Customer Adjustment Specification
30 Additional Functions 42 43
0 – Not applicable 0000 Not applicable
31 Pressure Control Options 44 45 46 Special Features
0 – Not applicable 000 – None ● ● ● ●

32 33 34 Power Control Specification *** – Defined by Eaton ● ● ● ●

000 – Not applicable 47 48 Design Number


** – 10-99 assigned by Eaton ● ● ● ●
35 Pilot Oil Filter
Pump Size 130 180 250 360 500 750
0 – Not applicable
Pump Size 130 180 250 360 500 750

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 11
● Preferred standard option
Model Code ● Other standard option
● Special option on request
Combination Pump Unit ✕ Not available

P *WC – * * * * * * * * * * * * * * * * * * * * H C 8 1 * * * * * * * * * *
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39

Unit Position 1 2 3 4 Unit Position 1 2 3 4


1 Combination Unit 11 12 13 Second Displacement cm3/rev (in3/rev)
P – Pump ● ● ● ● 066 – 66 (4.0) ●

090 – 90 (5.5) ●
2 Displacement 130 – 130 (7.9) ●

F – Fixed ● ● ● ● 180 – 180 (11.0) ●

V – Variable ● ● ● ● 250 – 250 (15.3) ●

360 – 360 (22.0) ●


3 Pump Series 500 – 500 (30.5) ●

W – W series (ex-30 design) ● ● ● ● 750 – 750 (45.8) ●

4 Unit Type 14 15 Second Control Type


00 – No control (fixed displacement only) ●
C – Combination unit ● ● ● ●
DF – Pressure compensator ●

5 Separator LR – Power control ●

– – Beginning of displacement and control SP – Proportional valve ●

DP – Pressure signal ●
specifications PQ – Digital controller ●
First Displacement cm3/rev (in3/rev) ES – Electric motor ●
6 7 8
▲ 16 17 18 Third Displacement
130 –– 130 (7.9) ●
Options as second displacement ●
180 – 180 (11.0) ●
19 20 Third Control Type
250 – 250 (15.3) ●

360 – 360 (22.0) ● Options as second control ●


500 – 500 (30.5) ● 21 22 23 Fourth Displacement
750 – 750 (45.8) ● Options as second displacement ●
▲ For special displacements, 24 25 Fourth Control Type
see basic pump model code Options as second control ●
9 10 First Control Type
26 27
00 – No control (fixed displacement only) ● Assembly Numbers
28 29
DF – Pressure compensator ●
HC81 Defined by Eaton ● ● ● ●
LR – Power control ●

SP – Proportional valve ● 30 31 32
DP – Pressure signal ● 33 34 35 Assembly Numbers
PQ – Digital controller ● 36 37 38
ES – Electric motor ● ***
*** Defined by Eaton ● ● ● ●
Unit Position 1 2 3 4 ***
Unit Position 1 2 3 4
Typical Combination Units Model Code
2 open-loop pumps Front Unit PVWF-500M08R0041R02SVMASPC03A0000000000000000010
Rear Unit PVWR-250M07R0001R02SVMASPC03A0000000000000000010
Combination Unit PVWC-500SP250SP0000000000HC81**********
1 closed-loop pump Front Unit TVWF-500M08R0000H1R02SVMA20SPC03C00000000E000H000000010
+ Middle Unit PVWM-250M07R00E1R02SV0ADF000A0000000000000000010
2 open-loop pumps Rear Unit PFXR-130M02R00P1A02SV0A00000A0000000000000000010
Combination Unit TVWC-500SP250DF1300000000HC81**********
Note: ISO spline shafts should be specified for For model codes of other individual units, see relevant catalogs.
combination units due to their higher torque capability.
Specifying Combination individual Model Codes of each combination, a separate Model combination, defined by Eaton
Pumps unit. Code should be compiled using and stated on the order
• The first displacement the Form page at the beginning acknowledgement.
• For a combination of two or represents the largest unit, and of the Model Codes section. • Front and middle units must
more units, a Combination so on. • Characters 26 to 39 of the each feature the through-drive
Model Code should be • For each unit included in the Combination Model Code will option of the following unit in
compiled in addition to the be part number of the the combination.

12 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Model Code
W-Series Open Loop Pumps

Form Page
The 48-digit coding system has or special features ( 44 to 46 ) Explanation for each character Codes
been developed to identify all are needed, please provide the
configuration options for the “W” Basic Pump Model Code 1 to 23
information when ordering.
series (Open Loop) fixed and
For combination units, you may Control Options 24 to 39
variable displacement pumps.
need to provide an additional
The Model Code lets you specify Customer Adjustment Specification
model code. In such a case, each 40 to 43
a unit with the desired features.
single pump section must be
All 48 digits must be present Special Features 44 to 46
specified separately using this or
when ordering.
other Eaton catalog information.
You may wish to photocopy the Where characters are already Design Number 47 & 28
matrix below to ensure that each stated in the blank Model Code,
number is entered in the correct Combination Units Model Code 1 to 39
there is no option available.
box. If adjustments other than
the standard setting ( 40 to 43 )

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

P W – 1 S V A

24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

1 0

Specify Non Standard Adjustment Below

Specify Special Feature Below

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 13
Pump
Specifications
Metric

Model PF/VW 130/180 PF/VW 250 PF/VW 360 PF/VW 500 PF/VW 750
Design Swashplate – Axial piston pump
Type of mounting Flange or foot-mounted - Combination units foot mounted only
Pipe connection ISO 6162-1 (SAE J518) B psi P64M (21/2” - 500) P89M (31/2” - 500) P89M (31/2” - 500) P127M (5” - 500) P127M (5” - 500)
SAE Flange ISO 6162-2 (SAE J518) A P32M (11/4” - 6000) P32M (11/4” - 6000) P32M (11/4” - 6000) P51M (2” - 6000 P51M (2” - 6000)
Direction of rotation Clockwise or counterclockwise
Mounting attitude Optional, see relevant Dimensions page
Ambient temperature range min ºC -20
max +50
Mass m kg 130 / 140 212 220 340 395
Moment of inertia J kg m2 0,045 0,146 0,152 0,5 0,55

Hydraulic Characteristics PF/VW 130/180 PF/VW 250 PF/VW 360 PF/VW 500 PF/VW 750
Rated pressure (100% duty cycle) pN bar 350
Inlet pressure p1min bar 1 abs
p1max 20
Max. pressure to ISO 5598:2008 p2max bar 420
Hydraulic fluid Hydraulic oil to DIN 51524 part 2
See Fluid Recommendations in Application Data
Hydraulic fluid temperature range min ºC -25
max +90
Viscosity range for continuous operation min cSt 10
max 75
Maximum permissible start viscosity max cSt 1000
Cleanliness ISO 4406 18/15/13
Maximum geometric displacement Vg cm3/rev
at shaft speed n = 1200 rev/min 130 / 180 250 360 500 750
n = 1500 rev/min 130 / 180 250 360 500 625/750 ▲
n = 1800 rev/min 130 / 180 250 270 410/500 ▲ –
Case pressure (overpressure) pcase bar
n = 1200 rev/min 3,2 2,8 2,8 2,35 2,1
n = 1500 rev/min 2,6 2,2 2,2 1,85 1,7
n = 1800 rev/min 2,0 1,6 1,6 1,35 –

Drive PF/VW 130/180 PF/VW 250 PF/VW 360 PF/VW 500 PF/VW 750
Driving torque (pN = 350 bar, M1single Nm 724/1002 1392 2005 2785 3481/4177
Vg at 1500 rev/min,  = 100%)
Power consumption (pN = 350 bar, P1single kW 113 / 157 218 315 437 546/656
Vg at 1500 rev/min,  = 100%)

Combination Units PF/VW 130/180 PF/VW 250 PF/VW 360 PF/VW 500 PF/VW 750
Maximum driving torque M1 Nm 2x870/2x1204 2 x 1670 2 x 2405 5000 5000
ISO splined shaft only

▲ Larger displacement / higher speed on request only. Contact Eaton Technical Support.

14 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Pump
Specifications
US

Model PF/VW 130/180 PF/VW 250 PF/VW 360 PF/VW 500 PF/VW 750
Design Swashplate – Axial piston pump
Type of mounting Flange or foot-mounted - Combination units foot mounted only
Pipe connection ISO 6162-1 (SAE J518) B psi P64M (21/2” - 500) P89M (31/2” - 500) P89M (31/2” - 500) P127M (5” - 500) P127M (5” - 500)
SAE Flange ISO 6162-2 (SAE J518) A P32M (11/4” - 6000) P32M (11/4” - 6000) P32M (11/4” - 6000) P51M (2” - 6000 P51M (2” - 6000)
Direction of rotation Clockwise or counterclockwise
Mounting attitude Optional, see relevant Dimensions page
Ambient temperature range min ºF -4
max +122
Mass m lb 215 467 485 750 871
Moment of inertia J lb ft2 3.46 3.46 3.61 11.9 13.1

Hydraulic Characteristics PF/VW 130/180 PF/VW 250 PF/VW 360 PF/VW 500 PF/VW 750
Rated pressure (100% duty cycle) pN psi 5075
Inlet pressure p1min psi 14.5 abs
p1max 290
Max. pressure to ISO 5598:2008 p2max psi 6090
Hydraulic fluid Hydraulic oil to DIN 51524 part 2
See Fluid Recommendations in Application Data
Hydraulic fluid temperature range min ºF -13
max +194
Viscosity range for continuous operation min cSt 10
max 75
Maximum permissible start viscosity max cSt 1000
Cleanliness ISO 4406 18/15/13
Maximum geometric displacement Vg in3/rev
at shaft speed n = 1200 rev/min 7.9 / 11 15.2 22 30.5 45.7
n = 1500 rev/min 7.9 / 11 15.2 22 30.5 38.1/45.7 ▲
n = 1800 rev/min 7.9 / 11 15.2 16.4 25/30.5 ▲ –
Case pressure (overpressure) pcase psi
n = 1200 rev/min 46 40 40 34 30
n = 1500 rev/min 38 32 32 27 25
n = 1800 rev/min 29 23 23 20 –

Drive PF/VW 130/180 PF/VW 250 PF/VW 360 PF/VW 500 PF/VW 750
Driving torque (pN = 5075 psi, M1single lbf ft 534/739 1027 1479 2054 2567/3081
Vg at 1500 rev/min,  = 100%)
Power consumption (pN = 5075 psi, P1single hp 152/211 293 422 586 733/880
Vg at 1500 rev/min,  = 100%)

Combination Units PF/VW 130/180 PF/VW 250 PF/VW 360 PF/VW 500 PF/VW 750
Maximum driving torque M1 lbf ft 2x642/2x888 2 x 1232 2 x 1774 3688 3688
ISO splined shaft only

▲ Larger displacement / higher speed on request only. Contact Eaton Technical Support.

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 15
Performance Curves
130 & 180 Series

Power Efficiency 100 100% K vol 200 Roller Bearing Life 106
Performance Curve Size 130
L10

Input power P1 (kW)


Size130 100%

Input torque (Nm)


K vol (%)
[h]
80 50%
V = Vmax

n=
105

150
25%

0 re
K tot (%)

n=

v/m
60

180

in
100

0 re
in
v/m

ni
/m

v/m
104
0 re

rev

40

in
180

00
15
n=

n=

t-off
20
torq ue cu 40
Input 103
20
0 0
p2 (bar) 0 100 200 300 400 p2 (bar) 50 100 200 300 400
p2 (psi) 0 1500 2900 4350 5800 p2 (psi) 70 1500 2900 4350 5800

Power Efficiency 100 100% K vol 400 Roller Bearing Life 106
Performance Curve K vol (%) Size 180
L10
Input power P1 (kW)

Size180 K tot (%) 100%

n=
[h]

150
80 50%
V = Vmax

0 re
105

v/m
n=
25%

in
180
60
0 re
v/m

200
min

in
ev/

104
40
0r
180

in
/m
n=

rev
00
15
n=

20
103

0
p2 (bar) 0 100 200 300 400 p2 (bar) 50 100 200 300 400
p2 (psi) 0 1500 2900 4350 5800 p2 (psi) 70 1500 2900 4350 5800

Double pumps For reduced swash angle Note


• For pumps operating in 1 Performance data is measured Eaton therefore shall not be held
tandem, typical values are as Lh = (L at Vmax) x under specific conditions and legally reponsible for any
10
for the individual units.
• Variable tandem units have
( )V
Vmax 3 may vary according to application
and operating conditions.
deviation from published figures.

two controls, i.e. one for each


single unit.

16 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Performance Curves
250 & 360 Series

Power Efficiency 100 100% K vol 400 Roller Bearing Life 106
Performance Curve Size 250
100% K tot L10

Input power P1 (kW)


Size250

n=
150
50% K tot [h]
80 V x 100

0 re
Vmax V = Vmax

v/m
105
25% K tot

in
n=
180
60

0 re
v/m
200
min

in
104
ev/

40
0r

in
180

/m
rev
n=

00
15
n=

20
103

0
p2 (bar) 0 100 200 300 400 p2 (bar) 50 100 200 300 400
p2 (psi) 0 1500 2900 4350 5800 p2 (psi) 70 1500 2900 4350 5800

Power Efficiency 100 500 Roller Bearing Life 106


100% K vol
Performance Curve Size 360
Input power P1 (kW)

Size360 100% K tot L10


50% K tot [h]
80
V = Vmax

n=
105

150
25% K tot

0 re
60 300

v/m
in
n=
180
in

104
/m

0 re
40 200
rev

v/m
00
15

in
n=

20 100
103

0 0
p2 (bar) 0 100 200 300 400 p2 (bar) 50 100 200 300 400
p2 (psi) 0 1500 2900 4350 5800 p2 (psi) 70 1500 2900 4350 5800

Combination units For reduced swash angle Note


• For combination pumps, 1 Performance data is measured Eaton therefore shall not be held
typical values are as for Lh = (L at Vmax) x under specific conditions and legally reponsible for any
10
individual units.
( )V
Vmax 3 may vary according to application
and operating conditions.
deviation from published figures.

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 17
Performance Curves
500 & 750 Series

Power Efficiency 100 500 Roller Bearing Life 106


100% K vol
Performance Curve Size 500

Input power P1 (kW)


Size500 100% K tot L10
[h]
80 V x 100 50% K tot
Vmax V = Vmax
105

n=
25% K tot

150
0 re
60 300

v/ m
n=

in
180
in
v/m

104

0 re
40 200
0 re

v/m
150

in
n=

20 100
103

0 0
p2 (bar) 0 100 200 300 400 p2 (bar) 50 100 200 300 400
p2 (psi) 0 1500 2900 4350 5800 p2 (psi) 70 1500 2900 4350 5800

Power Efficiency 100 1000 Roller Bearing Life 106


100% K vol
Performance Curve Size 750
Input power P1 (kW)

Size750 100% K tot L10


50% K tot [h]
80 V x 100
Vmax V = Vmax
n=
105
120
25% K tot
0 re
60 600 v/m
n=

in
150
in
/m

0 re

104
rev

40 400
v/m
00

in
/m
15

in
rev
n=

00
12

200
n=

20
103

0 0
p2 (bar) 0 100 200 300 400 p2 (bar) 50 100 200 300 400
p2 (psi) 0 1500 2900 4350 5800 p2 (psi) 70 1500 2900 4350 5800

Combination units For reduced swash angle Note


• For combination pumps, 1 Performance data is measured Eaton therefore shall not be held
typical values are as for Lh = (L at Vmax) x under specific conditions and legally reponsible for any
10
individual units.
( )V
Vmax 3 may vary according to application
and operating conditions.
deviation from published figures.

18 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Personal Notes

Eaton
Hydraulics Group EMEA
Hydrokraft plant
Am Joseph 16
D-61273 Wehrheim
Germany
Tel. +49 (0)6081103-324/-266/-235
Fax. +49 (0)6081103-342

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 19
Installation and Start-up

Warning: Care should be In those cases where Start-up Procedure Once the pump is started, it
taken that mechanical and geometric tolerances of Make sure the reservoir and should prime within a few
hydraulic resonances are mounting are critical, or where circuit are clean and free of seconds. If the pump does not
avoided in the application of specific tolerance ranges are dirt/debris prior to filling with prime, check to make sure that
the pump. Such resonances required and not specified, hydraulic fluid. there are no restrictions
can seriously compromise the consult Eaton Engineering for between the reservoir and the
life and/or safe operation of specific limits. Fill the reservoir with filtered inlet to the pump, and that the
the pump. oil and fill to a level sufficient pump is being rotated in the
Direction of shaft rotation, enough to prevent vortexing at proper direction, and that there
Drive Data viewed from the prime mover the suction connection to are no air leaks in the inlet line
end, must be as indicated in pump inlet. It is good practice and connections. Also check to
Mounting attitude should be the model designation on the to clean the system by
horizontal using the make sure that trapped air can
pump – either right hand flushing and filtering, using an escape at the pump outlet.
appropriate case drain ports to (clockwise) or left hand external slave pump.
ensure that the case remains (counterclockwise). After the pump is primed,
full of fluid at all times. Consult Caution: Before the pump is tighten the loose outlet
your local Eaton Direct coaxial drive through a connections, then operate for
started, fill the case through
Representative if a different flexible coupling is five to ten minutes (unloaded)
the uppermost drain port with
arrangement is required. recommended. If drives to remove all trapped air from
hydraulic fluid of the type to be
imposing radial shaft loads are the circuit.
used. The case drain line must
considered, please consult
be connected directly to the
your Eaton Representative. If the reservoir has a sight
reservoir and must terminate
gage, make sure the fluid is
below the oil level.
clear – not milky.

Fluid Cleanliness
Hydrokraft pumps are rated in Eaton Hydrokraft pumps, as Proper fluid condition is Essential information on the
anti-wear petroleum fluids with with any variable displacement essential for long and satisfac correct methods for treating
a contamination level of piston pumps, will operate tory life of hydraulic hydraulic fluid is included in
18/15/13 per ISO 4066. with apparent satisfaction in components and systems. Eaton publication 561 "Eaton
Operation in fluids with levels fluids up to the rating specified Hydraulic fluid must have the Guide to Systemic
more contaminated than this is here. Experience has shown correct balance of cleanliness, Contamination Control"
not recommended. Fluids however, that pump and materials, and additives for available from your local Eaton
other than petroleum, severe hydraulic system life is not protection against wear of distributor. In this publication,
service cycles, or temperature optimized with high fluid components, elevated filtration and cleanliness levels
extremes are cause for contamination levels (high ISO viscosity and inclusion of air. for extending the life of axial
adjustment of these codes. cleanliness codes). piston pumps and other
Please contact your Eaton system components are listed.
Representative for specific Included is an excellent
duty cycle recommendation. discussion of the selection of
products needed to control
fluid condition.

20 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Application Data and
Fluid Recommendations

Fluid Type DIN/ISO Rated Maximum Speed (rev/min) ■ Recommended Maximum Bearing Life
Classification Pressure pN 3 3 3
Seal Material Operating
(bar) 130 & 180 cm 250 &360 cm 500 & 750 cm Temperature (ºC)
Water Glycol ▲ HFC 250 1800 1500 1250 NBR 45 25-100%
HFDR (phosphate ester based) HFDR 350 1500 1200 1000 FKM 60 100% ▼
HFDU (glycol based) HFDU 350 1500 1200 1000 FKM 60 100% ▼
HFDU (ester based) HFDU 350 1800 1500 1250 FKM 60 100% ▼
HEES (synthetic ester) HEES 350 1800 1500 1250 FKM 60 100% ▼
■ See general specifications for speed limitation depending on displacement.
▲ For HFC operation, bearing flushing is mandatory. Highest speed only recommended at optimized application conditions.
Use Model Code 21 = "C" for seal option, and contact your Eaton Representative for validation.
Seal material can differ on an individual pump depending on specific seal function.
Bearing life with HFC fluid depends significantly on fluid temperature, cleanliness, quality, flushing and application parameters.
Typical values vary between 25% and 100% compared to mineral oil.
▼ Only fluids with fully saturated esters (iodine value <10) should be used.
HFDU and HEES fluids can be used at full ratings, but need to be monitored continuosly to maintain quality and performance. The
following important values should always be checked:
- Water content (<= 500 ppm)
- Fluid cleanliness (18/15/13 per ISO 4406)
- TAN value (no significant change from new oil)
- Viscosity (no significant change from new oil)
- Additives (no significant change from new oil)
Under harsh operation conditions, especially with regard to temperature and water content, ester-based HFDU and HFDR fluids are prone
to hydrolysis, the resulting chemical processes and products of which could damage seals and other pump components. In general, the
susceptibility to temperature and contamination is significantly higher than with standard mineral oils.
In line with Eaton Germany GmbH T&C warranty conditions covering use of HFDR/HFDU/HEES fluids, fluid-related damage is excluded.

Case/Bearing Flushing Vertical Mounting High pressure lubrication /


Case and bearing flushing are Vertical mounting of Hydrokraft Hydrostatic Balancing for Yoke
mandatory for HFC fluid pumps is possible, but venting Bearings (half-cup bearings)
operation, and recommended for and lubrication of shaft bearings High-pressure bearing lubrication
all other conditions where the can require special flushing and and balancing (Model Code For details and additional
pump is operating for longer installation procedures. For 21 = "K") is recommeded for information, please refer to the
intervals at low pressure i.e. details, please refer to the operating conditions with either "Hydrokraft Application Guideline
<20 bar (<300 psi) and/or low Hydrokraft Application Guideline high cycle frequencies (very Presentation" available from your
flow at high pressure Presentation available from your short up/downstroke times) Eaton Representative.
(compensated mode). Eaton Representative. and/or where the swashplate is
constantly maintained at a
Estimated Flushing Flow certain angle for long periods of
Values at 1500 rev/min time (compensated mode).
Pump Size Flushing Flow
(cm3/rev) (l/min)
130/180 4/5,5
250/360 7,5/11
500 15
750 20

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 21
General Dimensions
PVW 130 Pumps
Options illustrated:
12 = R (clockwise rotation)
14 15 = 00 (no thru drive)
18 19 = 01 (ISO keyed shaft)
22 = V (visual indicator)
24 25 = DF control (pressure compensator)

0 55 56 203 315
404
Visual X1*
position
indicator

92
9 20
305
L3* 140
L1* L2 L1* 404
L3.1* 20 Ref. (313) CW

53.5 +0.2 Ø200


72
Centrebore 104 113
DIN 332-D M16
L2* L1* L2*
4 x M12
-15 deep 200
82 80 156 B 18
209
X

346
Pressure compensator
pilot stage
Pressure compensator
main stage

MA*

Stroke limiter ML* L8* L5* MA*


50-100% of Vmax

A
Ø50 k6
72
f7
Ø160

14 h9

176 L3.1*
220 L3*
248 119
365
391

A – System pressure port ISO 6162-2 P32M (SAE J518 code 62, 11/4", 6000 psi) L5 – Oil filling plug 11/16"-12 UNF-2B
B – Inlet port ISO 6162-1 P64M (SAE J518 code 62, 21/2", 500 psi) L8 – Air bleed port G1/4"
L1 – Drain port 15/16"-12 UNF-2B (depending on mounting position, use upper port) MA – System pressure gauge port G1/4"
L2 – Drain port G1" (depending on mounting position, use upper port) ML – Case pressure gauge port G1/4"
L3 – Vent port for vertical mounting G3/8" (shaft upward) X1 – Remote port pressure compensator G1/4"-12.5 deep
L3.1 – Port G1/4" ...* – Connection with plug

22 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Shaft and
Mounting Options
PVW 130 Pumps

Mounting Flanges & Shaft Ends

78 Ø44.45 -0.05 (1 3/4")


75
W50x1.25x10a 9 20 9 20 11.1h9
DIN 5480

2.5 Ø152.400
5
152.337
Ø160.000
159.937 Ø200 49.2+ 0.2
.6
Ø228

Centrebore Centrebore
DIN 332-D DIN 332 28
36 45º 45º
M16 1
/2"-13UNC-2B 66 45º 45º
68 18 21
70.71 70.71 80.8 80.8
200 200

ISO splined shaft: 10 11 = 05 & 18 19 = 02 SAE D keyed shaft: 10 11 = 0D & 18 19 = D1

74
8/16DP-13T 9 20
ANSI B92.1

Ø152.400 3
152.337
8.6
Ø22

Centrebore
DIN 332 28
1
/2"-13UNC-2B 65 45º 45º
21
80.8 80.8
200

SAE D splined shaft: 10 11 = 0D & 18 19 = D2

Main Ports 50.8


M12-20 deep

31.8 M14-20 deep Ø63


Ø3
2

88.9
66.7

Port B
Port A View X

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 23
General Dimensions
PVW 180 Pumps
Options illustrated:
12 = R (clockwise rotation)
14 15 = 00 (no thru drive)
18 19 = 01 (ISO keyed shaft)
22 = V (visual indicator)
24 25 = DF control (pressure compensator)

0 55 56 203 315
404

Visual
X1*
position
indicator
A
92
9 20

L3* 404
140
L3.1* L1*
L2 CW L1* 305
20 Ref. (313)
53.5 +0.2 Ø200
72
Centrebore 104 113
DIN 332-D M16
L2* L1* L2*
4 x M12
-15 deep 200
82 80 156 B 209 18
X

346 Pressure compensator


pilot stage
Pressure compensator
main stage
MA*

Stroke limiter
MA*
50-100% of Vmax
ML* L8* L5*

Ø50 k6 72

Ø160 f7

14 h9

176
220 L3.1*
248 L3*
119
365
391

A – System pressure port ISO 6162-2 P32M (SAE J518 code 62, 11/4", 6000 psi) L5 – Oil filling plug 11/16"-12 UNF-2B
B – Inlet port ISO 6162-1 P64M (SAE J518 code 62, 21/2", 500 psi) L8 – Air bleed port G1/4"
L1 – Drain port 15/16"-12 UNF-2B (depending on mounting position, use upper port) MA – System pressure gauge port G1/4"
L2 – Drain port G1" (depending on mounting position, use upper port) ML – Case pressure gauge port G1/4"
L3 – Vent port for vertical mounting G3/8" (shaft upward) X1 – Remote port pressure compensator G1/4"-12.5 deep
L3.1 – Port G1/4" ...* – Connection with plug

24 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Shaft and
Mounting Options
PVW 180 Pumps

Mounting Flanges and Shaft Ends

78 Ø44.45 -0.05 (1 3/4")


75
W50x1.25x10a 9 20 9 20 11.1h9
DIN 5480

2.5 Ø152.400
5
152.337
Ø160.000
159.937 Ø200 49.2+ 0.2
.6
Ø228

Centrebore Centrebore
DIN 332-D DIN 332 28
M16 36 45º 45º 1
/2"-13UNC-2B 66 45º 45º
68 18 21
70.71 70.71 80.8 80.8
200 200

ISO splined shaft: 10 11 = 05 & 18 19 = 02 SAE D keyed shaft: 10 11 = 0D & 18 19 = D1

74
8/16DP-13T 9 20
ANSI B92.1

Ø152.400 3
152.337
8.6
Ø22

Centrebore
DIN 332 28
1 65 45º 45º
/2"-13UNC-2B 21
80.8 80.8
200

SAE D splined shaft: 10 11 = 0D & 18 19 = D2

Main Ports 50.8 M12-20 deep

31.8 Ø63
M14-20 deep
Ø3
2

88.9

66.7

Port B
Port A View X

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 25
General Dimensions
PVW 250 Pumps
Options illustrated:
12 = R (clockwise rotation)
14 15 = 00 (no thru drive)
18 19 = 01 (ISO keyed shaft)
22 = V (visual indicator)
24 25 = DF control (pressure compensator)

0 52 64 230 365
419
Visual X1*
position
indicator

117 A
8 20

L3* 460
L1* 160 L2 L1*
L3.1* Ø25 CW 361
Ref. (369) 0
69 +0.2 50

75 125
115
Centrebore
DIN 332-D M20
L2* L1* L2*
4 x M16
-18 deep
105 80 196 B 234 22
X

358 Pressure compensator


pilot stage
Pressure compensator
MA* main stage

Stroke limiter
ML* L8* L5*
50-100% of Vmax

Ø65 m6
81

Ø200 f7

18 h9

200 L3.1*
238
L3*
127
415
437

A – System pressure port ISO 6162-2 P38M (SAE J518 code 62, 11/2", 6000 psi) L5 – Oil filling plug 11/16"-12 UNF-2B
B – Inlet pressure port ISO 6162-1 P89M (SAE J518 code 61, 31/2", 500 psi) L8 – Air bleed port G1/4"
L1 – Drain port 15/8"-12 UNF-2B (depending on mounting position, use upper port) MA – System pressure gauge port G1/4"
L2 – Drain port G11/4" (depending on mounting position, use upper port) ML – Case pressure gauge port G1/4"
L3 – Vent port for vertical mounting G3/8" (shaft upward) X1 – Remote port pressure compensator G1/4"-12.5 deep
L3.1 – Port G1/8" ...* – Connection with plug

26 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Shaft and
Mounting Options
PVW 250 Pumps

Mounting Flanges and Shaft Ends

Ø44.42-44.43 (1 3/4")
92 79 11.1h9
W62x1.25x10a 9 20 9 20
DIN 5480
7.5
Ø31
2.5 Ø25 Ø165.1-0.05 6
0
Ø200f7 49.3+ 0.2

Centrebore 28
DIN 332-D
M20 Centrebore 67
42 DIN 332 D
45º 45º
80 22 M12 45º 45º 22
88.388 88.388
234 112.25 112.25
270
ISO splined shaft: 10 11 = 07 & 18 19 = 02
SAE E keyed shaft: 10 11 = 0E & 18 19 = E1

8/16DP-13T 84 Ø50.8m6 (2")


ANSI B92.1 8 20 12.7h9
100
9 20
7.5
Ø31 56.3+ 0.2
3 Ø35
0
Ø165.1-0.05 6
Ø177.8-0.05
28
Centrebore
Centrebore 67 DIN 332 D
DIN 332-D 45º M20
45º 22 42
M12 97
112.25 112.25 45º 22
270 45º
123.75 123.75
SAE E splined shaft: 10 11 = 0E & 18 19 = E2 290

SAE E keyed shaft: 10 11 = 0F & 18 19 = F1

88
8/16DP-15T 8 20
ANSI B92.1 Main Ports
0
Ø35
69.8 M16-40 deep
3 36.7 M16-30 deep
Ø177.8-0.05 Ø9
Ø3 0
8
Centrebore
DIN 332 79.4 120.7
5
/8"-11UNC-2B 36
76
45º 45º 22
123.75 123.75
290
Port A Port B
SAE F splined shaft: 10 11 = 0F & 18 19 = F2 View X

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 27
General Dimensions
PVW 360 Pumps
Options illustrated:
12 = R (clockwise rotation)
14 15 = 00 (no thru drive)
18 19 = 01 (ISO keyed shaft)
22 = V (visual indicator)
24 25 = DF control (pressure compensator)

0 52 64 230 381
433
Visual X1*
position
indicator

A
117
8 20

L3*
L1* 460
L3.1* 160 L2 L1*
Ref. (369) Ø25 CW
0 361
50
69 +0.2
75
115 125
Centrebore
DIN 332-D M20 L2* L2*
L1*
4 x M16
-18 deep
105 80 196 B 234 22
X

372 Pressure compensator


pilot stage
Pressure compensator
MA* main stage

Stroke limiter
50-100% of Vmax ML* L8* L5*

A
Ø65 m6 81

Ø200 f7

18 h9

L3.1*
200 L3*
238
127
426
448

A – System pressure port ISO 6162-2 P38M (SAE J518 code 62, 11/2", 6000 psi) L5 – Oil filling plug 11/16"-12 UNF-2B
B – Inlet pressure port ISO 6162-1 P89M (SAE J518 code 61, 31/2", 500 psi) L8 – Air bleed port G1/4"
L1 – Drain port 15/8"-12 UNF-2B (depending on mounting position, use upper port) MA – System pressure gauge port G1/4"
L2 – Drain port G11/4" (depending on mounting position, use upper port) ML – Case pressure gauge port G1/4"
L3 – Vent port for vertical mounting G3/8" (shaft upward) X1 – Remote port pressure compensator G1/4"-12.5 deep
L3.1 – Port G1/8" ...* – Connection with plug

28 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Shaft and
Mounting Options
PVW 360 Pumps

Mounting Flanges and Shaft Ends

Ø44.42-44.43 (1 3/4")
92 79 11.1h9
W62x1.25x10a 9 20 9 20
DIN 5480
7.5
Ø31
2.5 Ø25 Ø165.1-0.05 6
0
Ø200f7 49.3+ 0.2

Centrebore 28
DIN 332-D
M20 Centrebore 67
42 DIN 332 D
45º 45º
80 22 M12 45º 45º 22
88.388 88.388
234 112.25 112.25
270
ISO splined shaft: 10 11 = 07 & 18 19 = 02
SAE E keyed shaft: 10 11 = 0E & 18 19 = E1

8/16DP-13T 84 Ø50.8m6 (2")


ANSI B92.1 8 20 12.7h9
100
9 20
7.5
Ø31 56.3+ 0.2
3 Ø35
0
Ø165.1-0.05 6
Ø177.8-0.05
28
Centrebore
Centrebore DIN 332 D
67
DIN 332-D 45º M20
45º 22 42
M12 97
112.25 112.25 45º 22
270 45º
123.75 123.75
SAE E splined shaft: 10 11 = 0E & 18 19 = E2 290

SAE E keyed shaft: 10 11 = 0F & 18 19 = F1

88
8/16DP-15T 8 20
ANSI B92.1 Main Ports
0
Ø35
69.8
M16-40 deep
3 36.7
Ø3 M16-30 deep
Ø177.8-0.05 8
Ø90

Centrebore
DIN 332 79.4 120.7
5
/8"-11UNC-2B 36
76
45º 45º 22
123.75 123.75
290
Port A Port B
SAE F splined shaft: 10 11 = 0F & 18 19 = F2 View X

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 29
General Dimensions
PVW 500 Pumps
Options illustrated:
12 = R (clockwise rotation)
14 15 = 00 (no thru drive)
18 19 = 01 (ISO keyed shaft)
22 = V (visual indicator)
24 25 = DF control (pressure compensator)

0 52 100 192 467


478
Visual
position X1*
indicator

A
115
9 25

L3.1*
L3* 190 526
Ref. (436)
125 L1* CW L1* 434
18 L2
+0.2
74.5
Ø31
18 5
115 L2* L1* L2*
Centrebore 160 166
DIN 332-D
M20
4 x M16
-29 deep 300
105 95 255 310 26
X B

417 Pressure compensator


pilot stage
Pressure compensator
main stage
MA*

Stroke limiter
50-100% of Vmax ML* L8* L5*

MA*

A
Ø70 m6
95

Ø250 f7

20 h9

180 L3/L3.1*
328 178
542
564

A – System pressure port ISO 6162-2 P51M (SAE J518 code 62, 2", 6000 psi) L5 – Oil filling plug 11/16"-12 UNF-2B
B – System pressure port ISO 6162-1 P127M (SAE J518 code 61, 5", 500 psi) L8 – Air bleed port G1/4"
L1 – Drain port 15/8"-12 UNF-2B (depending on mounting position, use upper port) MA – System pressure gauge port G1/4"
L2 – Drain port G11/2" (depending on mounting position, use upper port) ML – Case pressure gauge port G1/4"
L3 – Vent port for vertical mounting G3/8" (shaft upward) X1 – Remote port pressure compensator G1/4"-12.5 deep
L3.1 – Port G3/8" ...* – Connection with plug

30 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Shaft and
Mounting Options
PVW 500 Pumps

Mounting Flanges and Shaft Ends

141 20
106 16
106
10 25 104.5
W80x3.25x10a
DIN 5480
Ø45

315.000 A Ø36 5
2 Ø 314.919 0 Ø40
Ø250f7

Ø315
Centrebore C/bore DIN 332-D
DIN 332-D M20 42
M20 W80x3.25x10a
DIN 5480

42 45º
95 45º
26

22.5
º
111.37 111.37 8x45º
300 380

ISO splined shaft: 10 11 = 08 & 18 19 = 02 ISO special splined shaft: 10 11 = 09 & 18 19 = 05

Main Ports

92.1 M16-20 deep


44.5 M20-25 deep
Ø5 Ø1
0 25

96.8 152.4

Port A Port B
View X

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 31
General Dimensions
PVW 750 Pumps
Options illustrated:
12 = R (clockwise rotation)
14 15 = 00 (no thru drive)
18 19 = 02 (ISO splined shaft)
22 = V (visual indicator)
24 25 = DF control (pressure compensator)

0 56 107 199 496


525
Visual
position X1*
indicator
A

115 32
9

L3.1*
CW
190 535
L3* L2 L1*
125 L1* Ref. (444) Ø31
18 5 436

Centrebore 18 115
DIN 332-D L2* 155 172
M24
L1* L2*
4 x M16
-29 deep 300
B 26
105 102 255 X 316

462
Pressure compensator
pilot stage
Pressure compensator
main stage
MA*
Stroke limiter
50-100% of Vmax ML* L8* L5*
MA*

95

Ø250 f7

W90x3x28x9g
DIN5480

180
326 185
571
593

A – System pressure port ISO 6162-2 P51M (SAE J518 code 62, 2", 6000 psi) L5 – Oil filling plug 11/16"-12 UNF-2B
B – System pressure port ISO 6162-1 P127M (SAE J518 code 61, 5", 500 psi) L8 – Air bleed port G1/4"
L1 – Drain port 15/8"-12 UNF-2B (depending on mounting position, use upper port) MA – System pressure gauge port G1/4"
L2 – Drain port G11/2" (depending on mounting position, use upper port) ML – Case pressure gauge port G1/4"
L3 – Vent port for vertical mounting G3/8" (shaft upward) X1 – Remote port pressure compensator G1/4"-12.5 deep
L3.1 – Port G3/8" ...* – Connection with plug

32 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Shaft and
Mounting Options
PVW 750 Pumps

Mounting Flanges and Shaft Ends Main Ports

ISO splined shaft: 10 11 = 08 & 18 19 = 02


as illustrated on the previous page is the only arrangement suitable for
Hydrokraft pumps PVW 750. 92.1 M16-20 deep
44.5 M20-25 deep
Ø1
25
Ø5
0

96.8 152.4

Port A Port B
View X

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 33
Control Options DF & LR

General Description LR Controls As an additional option,


Energy-saving hydraulic drives The typical p/Q curve is a maximum (or minimum) flow
are possible with pressure hyperbola. For constant speed, can also be limited by a spacer
compensated and/or power the drive torque, i.e. the power inside the control cylinder
controlled pumps, especially in used, is held constant. (Model Code position 13 ,
combination with the options 4, 5 or 6, in combination
The power hyperbola can be with customer adjustment
loadsensing option. continuously adjusted between specified in positions 40 to 43 ).
Pmin and Pmax. Pmin is given by the
DF Controls minimum setting of the control This solution is also
System pressure remains main stage (20 bar approx.) and recommended for severe
constant for the entire volume power loss of the pump. operating conditions and the
flow rate. System pressure can need for high repeatability over a
Both controller types can be long period of time. The setting
be set manually, hydraulically or combined with another or with
electronically. must be defined before ordering
additional options; for available since it cannot be modified in
The standard Hydrokraft options, see Model Code. operation.
pressure compensator is pilot Maximum pump flow can be
operated, has a remote port and limited mechanically to between
is very stable. 50% and 100% by a screw.

34 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Control Options DF
For pump details, see general
Installation Dimensions.

DF000A0 Pressure compensator 70 215


pilot stage 45 175
Options illustrated:
24 25 = DF (pressure compensator)
Pressure compensator
29 = A (yoke angle 1 side of centre) main stage 86
91
For pump details, see general 41
Installation Dimensions.
Ref. dim. for size 130-750

A – System port
B – Inlet port
L1, L2 – Drain port
L3 – Vent port for vertical mounting
L3.1, L8 – Air bleed port
L5 – Oil filling plug
MA – Gauge port, system pressure
ML – Gauge port, case pressure
X1 – Remote port pressure
compensator

1 – Basic pump
2 – Connection plate for DF-control
3.1 – Pressure compensator,
main stage
3.2 – Pressure compensator,
pilot stage

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 35
Control Options DF (cont.)
For pump details, see general
Installation Dimensions.

71
DF000A0K 46 175
165
Options illustrated:
Proportional relief valve
24 25 = DF (pressure compensator)
29 = A (yoke angle 1 side of centre)
31 = K (proportional relief valve)
135
Pressure compensator
main stage

41

Ref. dim. for size 130-750

A – System port
B – Inlet port
L1, L2 – Drain port
L3 – Vent port for vertical mounting
L3.1, L8 – Air bleed port
L5 – Oil filling plug
MA – Gauge port, system pressure
ML – Gauge port, case pressure
X1 – Remote port pressure
compensator

1 – Basic pump
2 – Connection plate for DF-control
3 – Pressure compensator,
lmain stage
4 – Proportional relief valve

36 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Control Options DF (cont.)
For pump details, see general
Installation Dimensions.

DF000A1 65 215
Pressure compensator 45 175
Options illustrated: pilot stage
24 25 = DF (pressure compensator)
Pressure compensator
29 = A (yoke angle 1 side of centre) main stage 132
30 = 1 (load sensing)

Load-sensing valve 82

41

Ref. dim. for size 130-750

A, B – System port
L1, L2 – Drain port
L3 – Port for front bearing flushing
(vent port for vertical mounting)
L3.1, L8 – Air bleed port
L5 – Oil filling plug
MA – Gauge port, system pressure
ML – Gauge port, case pressure
X1 – Remote port pressure limiter
override G1/4
X2 – Remote port, load sense

1 – Basic pump
2 – Connection plate for DF-control
3.1 – Pressure limiter override,
load sense stage
3.2 – Pressure limiter override,
lmain stage
3.3 – Pressure limiter override,
pilot stage

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 37
Control Options DF (cont.)
For pump details, see general
Installation Dimensions.

DF000AA/DF000AB 71

Options illustrated: 47
24 25 = DF (pressure compensator) Solenoid valve DF000AB DF000AA
29 = A (yoke angle 1 side of centre)
30 = A or B (2-level
pressure compensator) Pressure compensator 175 233
pilot stage 175

Pressure compensator
main stage 81
41

Ref. dim. for size 130-750

DF000AA DF000AB

A, B – System port
L1, L2 – Drain port
L3 – Vent port for vertical mounting
L3.1, L8 – Air bleed port
L5 – Oil filling plug
MA – Gauge port, system pressure
ML – Gauge port, case pressure
X1 – Remote port pressure limiter
override G1/4

1 – Basic pump
2 – Connection plate for DF-control
3.1 – Pressure limiter override,
main stage
3.2 – Double relief stack valve
3.3 – Solenoid valve
3.4 – 4/3 directional valve

38 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Control Options DF (cont.)
For pump details, see general
Installation Dimensions.

268
Pressure compensator 215
pilot stage 128
DF000A1-100H 175
Options illustrated:
Venting valve
24 25 = DF (pressure compensator)
29 = A (yoke angle 1 side of centre)
30 = 1 (load sensing) Pressure compensator
main stage 195
36 = 1 (venting valve)
39 = H (24V DC) 165
Load-sensing valve 115

Ref. dim. for size 130-750

A, B – System port
L1, L2 – Drain port
L3 – Vent port for vertical mounting
L3.1, L8 – Air bleed port
L5 – Oil filling plug
MA – Gauge port, system pressure
ML – Gauge port, case pressure
X1 – Remote port pressure limiter
override G1/4
X2 – Remote portload sense

1 – Basic pump
2 – Connection plate for DF-control
3.1 – Pressure limiter override,
load sense stage
3.2 – Pressure limiter override,
main stage
3.3 – Venting valve
3.4 – Pressure limiter override,
pilot stage

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 39
Control Options LR
For pump details, see general
Installation Dimensions.

133 219
70 185
LR00A20 Pressure compensator 45 179
pilot stage
Options illustrated:
Pressure and power
24 25 = LR (power control) compensator main stage
91
29 = A (yoke angle 1 side of centre)
30 = 2 (pressure limiter) 41
31 = 0 (standard)
Power
Ref. dim. for size 130-750 compensator
pilot stage
90

Pump Size 130 180 250 360 500 750


Total Width (mm) 451 451 446 484 505 574
LR Control A20 215 215 219 219 219 219
Type A2F 188 188 185 185 185 185
A30 215 215 219 219 219 219

A – System port
B – Inlet port
L1, L2 – Drain port
L3 – Vent port for vertical mounting
L3.1, L8 – Air bleed port
L5 – Oil filling plug
MA – Gauge port, system pressure
ML – Gauge port, case pressure
X1 – Remote port pressure
compensator

1 – Basic pump
2 – Connection plate for LR-control
3 – Pressure and power
compensator, main stage
4 – Pressure compensator,
pilot stage
5 – Power compensator,
pilot stage

40 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Control Options LR (cont.)
For pump details, see general
Installation Dimensions.

133 185
LR00A2F Pressure and power 70 179
Options illustrated: compensator main stage
53
24 25 = LR (power control) 41
29 = A (yoke angle 1 side of centre)
Power
30 = 2 (pressure limiter) Ref. dim. for size 130-750 compensator
31 = F (remote pilot port) pilot stage
90

Pump Size 130 180 250 360 500 750


Total Width (mm) 451 451 446 484 505 574
LR Control A20 215 215 219 219 219 219
Type A2F 188 188 185 185 185 185
A30 215 215 219 219 219 219

A – System port
B – Inlet port
L1, L2 – Drain port
L3 – Vent port for vertical mounting
L3.1, L8 – Air bleed port
L5 – Oil filling plug
MA – Gauge port, system pressure
ML – Gauge port, case pressure
X1 – Remote port pressure
compensator

1 – Basic pump
2 – Connection plate for LR-control
3 – Pressure and power
compensator, main stage
4 – Closing plate
5 – Power compensator,
pilot stage

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 41
Control Options LR (cont.)
For pump details, see general
Installation Dimensions.

219
LR00A30 133 185
Pressure compensator 94 179
Options illustrated: pilot stage
24 25 = LR (power control) Pressure and power
29 = A (yoke angle 1 side of centre) compensator
main stage 132
30 = 3 (load sensing
+ pressure limiter)
31 = 0 (standard) Load sensing valve 82

41

Ref. dim. for Power


size 130-750 compensator
pilot stage
Pump Size 130 180 250 360 500 750
90
Total Width (mm) 451 451 446 484 505 574
LR Control A20 215 215 219 219 219 219
Type A2F 188 188 185 185 185 185
A30 215 215 219 219 219 219

A – System port
B – Inlet port
L1, L2 – Drain port
L3 – Vent port for vertical mounting
L3.1, L8 – Air bleed port
L5 – Oil filling plug
MA – Gauge port, system pressure
ML – Gauge port, case pressure
X1 – Remote port pressure
compensator
X2 Remote port load sense

1 – Basic pump
2 – Connection plate for LR-control
3 – Pressure and power
compensator, main stage
4 – Closing plate
5 – Power compensator,
pilot stage

42 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Control Options SP

General Description A proportional valve and servo Maximum pump flow can be This solution is recommended
The energy-saving piston use the controller output limited mechanically to between for severe operating conditions
electrohydraulic displacement signal to apply the required 50% and 100% by a screw. As and the need for high
control type SP efficiently setting, resulting in a highly an additional option, maximum repeatability over a long period
adjusts pump output by acting accurate dynamic control (or minimum) flow can be set of time. The setting must be
on the swashplate within system. by a spacer inside the control defined before ordering since it
electrically adjustable limits. The cylinder (Model Code cannot be modified in operation..
Hysteresis is approximately 1% position 13 , options 4, 5 or 6,
swashplate angle value is fed of end value. The SP control can
back to the controller unit via an in combination with customer
also be combined with adjustment specified in positions
electrical closed loop system. hydromechanical relief valves for 40 to 43 ).
pressure and/or power control.

Pump Dimensions with Options illustrated:


SPC03A0 Control 24 25 = SP (displacement
adjustment via
For basic pump details, see proportional valve)
26 = C (CETOP 3 proportional
general Installation Dimensions.
valve KDG4V-3)
30 = 0 (no additional function)
35 = E (filter with electrical
indicator)
36 = 0 (no venting valve)

K A
H B

G
F
D
C

Response Time @ 1500 rev/min, SP Control with Pilot Pump Option (...OOP)
Pump Overall Dimensions with Control SPC03A0 (mm) Main Pump Size Pilot Pump Size Pilot Pressure Up/Downstroke time
Pump Size A B C D F G H K L (cm3/rev) (bar) 0-100% displ. (ms) approx.
130 446 346 192 234 282 368 183 490 113 130 8 60 450
180 446 346 192 234 282 368 183 490 113 180 8 60 450
250 461 361 236 278 326 412 212 535 125 250 8 60 550
360 475 375 236 278 326 412 212 551 125 360 8 60 700
500 520 420 268 310 358 444 212 659 166 500 8 90 650
750 562 462 270 312 460 446 212 689 166 750 8 90 850

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 43
Control Options SP (cont.)
For basic pump details,
see general Installation Dimensions.

Pump dimensions with


SPC03A0 control (cont.)

A – System port
B – Inlet port
L1, L2 – Drain port
L3 – Vent port for vertical mounting
L3.1, L8 – Air bleed port
L5 – Oil filling plug
MA – Gauge port, system pressure
ML – Gauge port, case pressure
PSt1 – Pilot pressure inlet port
PSt2 – Pilot pump outlet port
MSt – Pilot pressure gauge port
S – Pilot pump inlet port

1 – Basic pump
2 – Connection plate for SP-control
2.1 – Pilot pressure relief valve
3 – Pilot oil filter
4 – Proportional control valve
5 – Pilot pump

44 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Control Options SP (cont.)
For basic pump details,
see general Installation Dimensions.

SPC03A4
Options illustrated: A
Proportional control valve
24 25 = SP (displacement adjust-
ment via proportional valve) Pressure filter
26 = C (CETOP 3 proportional
valve KDG4V-3)
Pressure limiter override
30 = 4 (pressure limiter override) Main stage
35 = E (filter with electrical indicator)
36 = 0 (no venting valve) G
F
Pump Overall Dimensions Pressure limiter override
with Control SPC03A4 (mm) Pilot stage
E
Pump Size A E F G
130 446 274 322 408
180 446 274 322 408
250 461 318 366 452
360 475 318 366 452
500 520 350 398 484
750 562 352 400 486

A – System port
B – Inlet port
L1, L2 – Drain port
L3 – Vent port for vertical mounting
L3.1, L8 – Air bleed port
L5 – Oil filling plug
MA – Gauge port, system pressure
ML – Gauge port, case pressure
PSt1 – Pilot pressure inlet port
PSt2 – Pilot pump outlet port
MSt – Pilot pressure gauge port
X1 – Remote port pressure limiter
override
S – Pilot pump inlet port

1 – Basic pump
2 – Connection plate for SP-control
2.1 – Pilot pressure relief valve
3 – Subplate
4 – Pilot oil filter
5 – Proportional control valve
6 – Pressure limiter override,
main stage
7 – Pressure limiter override,
pilot stage
8 – Pilot pump

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 45
Control Options SP (cont.)
For basic pump details,
see general Installation Dimensions.

SPC03A5 A Proportional control valve


Options illustrated:
24 25 = SP (displacement adjust- Pressure filter
ment via proportional valve)
26 = C (CETOP 3 proportional
valve KDG4V-3) Pressure and power limiter override
30 = 5 (pressure and power Main stage
limiter override)
35 = E (filter with electrical indicator) G
36 = 0 (no venting valve) F
E Pressure limiter override
Pilot stage
Pump Overall Dimensions
with Control SPC03A5 (mm)
Pump Size A E F G
130 516 274 322 408 Power limiter override
180 516 274 322 408 Pilot stage
250 514 318 366 452
360 540 318 366 452
500 573 350 398 484
750 624 352 400 486

A – System port
B – Inlet port
L1, L2 – Drain port
L3 – Vent port for vertical mounting
L3.1, L8 – Air bleed port
L5 – Oil filling plug
MA – Gauge port, system pressure
ML – Gauge port, case pressure
PSt1 – Pilot pressure inlet port
PSt2 – Pilot pump outlet port
MSt – Pilot pressure gauge port
X1 – Remote port pressure limiter
override
S – Pilot pump inlet port

1 – Basic pump
2 – Connection plate for SP-control
2.1 – Pilot pressure relief valve
3 – Subplate
4 – Pilot oil filter
5 – Proportional control valve
6 – Pressure and Power limiter
override, main stage
7 – Pressure limiter override,
pilot stage
8 – Power limiter override,
pilot stage
9 – Pilot pump

46 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Control Options SP (cont.)
For basic pump details,
see general Installation Dimensions.

SPD0 A
Proportional control valve
Options illustrated:
24 25 = SP (displacement adjust-
ment via proportional valve)
26 = D (CETOP 3 proportional
G
valve KBS-3 with OBE)
30 = 0 (no additional function)
35 = 0 (no pilot oil filter)
36 = 0 (no venting valve)

Pump Overall Dimensions


With Control SPD0 (mm)
Pump Size A G
130 446 350
180 446 350
250 461 394
360 475 394
500 520 426
750 562 428

A – System port
B Inlet port
L1, L2 – Drain port
L3 – Vent port for vertical mounting
L3.1, L8 – Air bleed port
L5 – Oil filling plug
MA – Gauge port, system pressure
ML – Gauge port, case pressure
PSt1 – Pilot pressure inlet port
PSt2 – Pilot pump outlet port
MSt – Pilot pressure gauge port
S – Pilot pump inlet port

1 – Basic pump
2 – Connection plate for SP-control
2.1 – Pilot pressure relief valve
3 – Proportional control valve
4 – Pilot pump

Min. Response Time @ 1500 rev/min with SPD Control Min. Response Time @ 1500 rev/min with SPE Control
Main Pump Size Pilot Flow Pilot Pressure Up/Downstroke time Main Pump Size Pilot Flow Pilot Pressure Up/Downstroke time
Required (l/min) Required (bar) 0-100% displ. (ms) approx. Required (l/min) Required (bar) 0-100% displ. (ms) approx.
130 40 130 100 130 50 150 85
180 40 130 100 180 50 150 85
250 45 150 120 250 55 200 100
360 55 150 130 360 65 200 115
500 60 200 150 500 55 250 125
750 65 200 150 750 70 250 135

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 47
Control Options DP

General Description The DP control can be used for Maximum pump flow can be This solution is recommended
Pump output flow is proportional stepless flow control with limited mechanically to between for severe operating conditions
to pilot pressure. A separate standard requirements for 50% and 100% by a screw. As and the need for high
pilot oil circuit is required to dynamics and accuracy. No an additional option, maximum repeatability over a long period
reduce control pressure to the feedback signal is needed; an (or minimum) flow can be set by of time. The setting must be
set value, using a suitable relief optical indicator is recommended a spacer inside the control defined before ordering since it
valve in line P-T and throttle (Model Code position 12 ,= V). cylinder (Model Code cannot be modified in operation..
valve in line P, Ø 0,8 (0.03 in). position 13 , options 4, 5 or 6,
in combination with customer
adjustment specified in positions
40 to 43 ).

Pump Dimensions with Options illustrated:


DPJ...A0 Control 24 25 = DP (pilot pressure
adjusted displacement)
26 = J (proportional KCG
For basic pump details, see
general Installation Dimensions. relief valve)
30 = 0 (no additional function)
35 = 0 (no pilot oil filter)

K
I A
H B

G
F
E
D
CW C

Response Time @ 1500 rev/min, DP Control with Pilot Pump Option (OP)
Pump Overall Dimensions With Control DPJ00A0 (mm) Main Pump Size Pilot Pump Size Pilot Pressure Up/Downstroke time
Pump Size A B C D E F G H I K L (cm3/rev) (bar) 0-100% displ. (ms) approx.
130 446 346 192 232 312 366 374 247 203 490 113 130 8 60 1100
180 446 346 192 232 312 366 374 247 203 490 113 180 8 60 1100
250 461 361 236 276 356 410 418 247 230 535 125 250 8 60 1200
360 475 375 236 276 356 410 418 247 230 551 125 360 8 60 1600
500 520 420 268 308 388 442 450 247 300 659 166 500 8 90 1600
750 562 462 270 310 390 444 452 247 307 689 166 750 8 90 2000

48 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Control Options DP (cont.)
For basic pump details,
see general Installation Dimensions.

Pump dimensions with


DPJ...A0 control (cont.)

A, B – System port
L1, L2 – Drain port
L3 – Vent port for vertical mounting
L3.1, L8 – Air bleed port
L5 – Oil filling plug
L7 – External port oil return line
(optional)
MA – Gauge port, system pressure
ML – Gauge port, case pressure
PSt1 – Pilot pressure inlet port
PSt2 – Pilot pump outlet port
MSt – Pilot pressure gauge port
S – Pilot pump inlet port

1 – Basic pump
2 – Connection plate for DP-control
3 – DP control
3.1 – Pilot pressure relief valve
4 – Connection plate for
proportional valve
5 – Proportional relief valve
6 – Pilot pump

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 49
Control Options DP (cont.)
For basic pump details,
see general Installation Dimensions.

Pilot oil relief valve adjustment


DPJ...A4
Options illustrated: A
Proportional relief valve
24 25 = DP (pilot pressure M
adjusted displacement) Pressure limiter override
26 = J (proportional KCG Zero adjustment Main stage
relief valve)
30 = 4 (pressure limiter override)
35 = 0 (no pilot oil filter)

G
Pump Overall Dimensions
F
with Control DPJ4 (mm)
Pump Size A F G M
130 446 366 374 176 Pressure limiter override
Pilot stage
180 446 366 374 176
250 461 410 418 176
360 475 410 418 176
500 520 442 450 176
750 562 444 452 176

A, B – System port
L1, L2 – Drain port
L3 – Vent port for vertical mounting
L3.1, L8 – Air bleed port
L5 – Oil filling plug
L7 – External port oil return line
(Optional)
MA – Gauge port, system pressure
ML – Gauge port, case pressure
PSt1 – Pilot pressure inlet port
PSt2 – Pilot pump outlet port
MSt – Pilot pressure gauge port
X1 – Remote port pressure limiter
override
S – Pilot pump inlet port

1 – Basic pump
2 – Connection plate for DP-control
3 – DP control
3.1 – Pilot pressure relief valve
4 – Connection plate for
proportional valve
5 – Pressure limiter override,
main stage
6 – Pressure limiter override,
pilot stage
7 – Proportional relief valve
8 – Pilot pump

50 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Control Options DP (cont.)
For basic pump details,
see general Installation Dimensions.

DPJ...A5
Pilot oil relief valve adjustment
Options illustrated: A
Proportional relief valve M
24 25 = DP (pilot pressure
adjusted displacement) Zero adjustment
26 = J (proportional KCG Pressure and power limiter override
relief valve) Main stage
30 = 5 (pressure and power
limiter override)
35 = 0 (no pilot oil filter)
G
F
Pump Overall Dimensions
with Control DPJ5 (mm) Pressure limiter override
Pilot stage
Pump Size A F G M
130 516 366 374 176 Pressure limiter override
180 516 366 374 176 Pilot stage
250 514 410 418 176
360 537 410 418 176
500 575 442 450 176
750 624 444 452 176

A, B – System port
L1, L2 – Drain port
L3 – Vent port for vertical mounting
L3.1, L8 – Air bleed port
L5 – Oil filling plug
L7 – External port oil return line
(Optional)
MA – Gauge port, system pressure
ML – Gauge port, case pressure
PSt1 – Pilot pressure inlet port
PSt2 – Pilot pump outlet port
MSt – Pilot pressure gauge port
X1 – Remote port pressure limiter
override
S – Pilot pump inlet port

1 – Basic pump
2 – Connection plate for DP-control
3 – DP control
3.1 – Pilot pressure relief valve
4 – Connection plate for
proportional valve
5 – Pressure and power limiter
limiter override, main stage
6 – Pressure limiter override,
pilot stage
7 – Power limiter override,
pilot stage
8 – Proportional relief valve
9 – Pilot pump

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 51
Control Options DP (cont.)
For basic pump details,
see general Installation Dimensions.

DPG...A0 A
Pilot oil relief valve adjustment
CETOP 3 interface M
Options illustrated:
24 25 = DP (pilot pressure
Zero adjustment
adjusted displacement)
26 = G (CETOP 3 interface)
30 = 0 (no additional function)
G
35 = 0 (no pilot oil filter)
F

Pump Overall Dimensions


with Control DPG (mm)
Pump Size A F G M
130 446 361 374 82
180 446 361 374 82
250 461 405 418 82
360 475 405 418 82
500 520 437 450 82
750 562 439 452 82

A, B – System port
L1, L2 – Drain port
L3 – Vent port for vertical mounting
L3.1, L8 – Air bleed port
L5 – Oil filling plug
L7 – External port oil return line
{optional)
MA – Gauge port, system pressure
ML – Gauge port, case pressure
PSt1 – Pilot pressure inlet port
PSt2 – Pilot pump outlet port
MSt – Pilot pressure gauge port
S – Pilot pump inlet port

1 – Basic pump
2 – Connection plate for DP-control
3 – DP control
3.1 – Pilot pressure relief valve
4 – Connection plate for
proportional valve
5 – Pilot pump

52 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Control Options DP (cont.)
For basic pump details,
see general Installation Dimensions.

DPH...A0
A
Options illustrated: Pilot oil relief valve adjustment
24 25 = DP (pilot pressure M
adjusted displacement) Zero adjustment
26 = H (Remote port G1/4")
30 = 0 (no aditional function) Pressure and power limiter override
35 = 0 (no pilot oil filter) Main stage

Pump Overall Dimensions


with Control DPG (mm)
G
Pump Size A F G M
F
130 446 361 374 82
180 446 361 374 82
250 461 405 418 82
360 475 405 418 82
500 520 437 450 82
750 562 439 452 82

A, B – System port
L1, L2 – Drain port
L3 – Vent port for vertical mounting
L3.1, L8 – Air bleed port
L5 – Oil filling plug
MA – Gauge port, system pressure
ML – Gauge port, case pressure
PSt1 – Pilot pressure inlet port
PSt2 – Pilot pump outlet port
MSt – Pilot pressure gauge port
S – Pilot pump inlet port
ASt – G 1/4"
BSt – G 1/4"
P – G 1/4"
T – G 1/4"

1 – Basic pump
2 – Connection plate for DP-control
3 – DP control
3.1 – Pilot pressure relief valve
4 – Plate with 4x G1/4" ports
5 – Pilot pump

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 53
Control Options PQ

General Description Pressure Cut-Off Control directly proportional to flow. Master-Slave Function
Flow Control The ER9.X-10 controller measures Should power exceed command A number of pumps operate in
pressure in both lines, as indicated signal levels, the controller parallel, one set as master and the
The ER9.X-10 digital controller generates a maximum internal
measures the actual swash-plate by pressure sensors, reducing others as slaves. The master pump
output levels in the event of actual flow command signal in line with is fitted with a fully active PpQ
position from sensor data, maximum input power.
comparing the swash-plate angle pressure exceeding the command controller, while the slave units,
with the set value and driving the signal. Mooring Control running in flow-control mode,
servo or proportional valve Power Cut-Off Control (on request only) follow the displacement response
accordingly. Swash plate angle as Pressure Cut-Off control is of the master unit.
The ER9.X-10 calculates actual
well as pump displacement and power by measuring pressures designed to operate to full 100%
outlet flow are regulated to match and swash plate angle, which is overcentre. This allows for
set values. intelligent Mooring Control.

PpQ Controller Model Code ER9.X - 0000 - *00 - 10


1 – 5 6 – 10 11 – 14 15 – 18

1 - 5 Digital Controller 6 - 10 Customer Adjustment 11 - 14 Special Features for 15 - 18 Design Number


Series Specification for Special Design 10 – Subject to change
ER9.X – Amplifier card for PpQ Customized Options
control functions Parameter Settings 000 – Standard features
0000 – Standard parameters P00 – ProfiBus version
Note: ER9.X-10 Digital Controllers must be ordered as separate items from pumps.

ER9.X Controller Card with the provisions of European • Controls displacement-Q, • Four storable and adjustable
Functionality Directive 2004/108/EC governing power-P and pressure-p. digital set points (one additional
The digital amplifier and controller Electromagnetic Compatibility • Multilingual. point is optional).
card assembly ER9.X-10 is used (EMC), which ensure high • Direction externally set through
interference immunity coupled • Easy parameter setting and
for the electronic PpQ control of documentation. "+" and "-" inputs.
displacement, pressure and power with low interference emission.
The electronic card is tested to • 4 channel oscilloscope function • Enable signal for output stages.
on Eaton PVW variable piston
DIN EN 60068-2-6 (vibration) and included. • Ramp function and Reset-Ramp
pumps (W design). The swash
DIN EN 60068-2-27 (mechanical • Differential amplifier input (flow for fast ramp function zeroing.
plate is positioned by either an
Eaton KBS proportional valve or shock). It features a display and six command) for set points in the • Status outputs: Error and
one of a range of suitable buttons to adjust card parameters. range of 0 to ±10V, 14-bit Comparator.
servovalves. The digital amplifier Configuring the digital amplifier resolution.
and controller card is also possible • All digital inputs and outputs are
and controller card have been • Single ended, independent set optically isolated for functional
designed and tested to comply via an RS232 serial interface and
the ER9.X-Tool software included. point input (pressure command) security.
for the range of 0 to +10V, • Four 7-segment displays and
14-bit resolution. six buttons for display and
• 2 single ended, independent functionality ease.
set point inputs (Power • Function indication through
command) for the range of 0 to front panel by LEDs.
+10V, 14-bit resolution.
• Additional switching output
• 3 sensor inputs for 0-20 mA or (24V, max 1A) to directly disable
4-20 mA sensor signals safety valve.
(swashplate feedback, pressure
in A+B), 14-bit resolution. • Additional front panel test jacks
for easy commissioning.
• Integrated reference supply
voltage of ±10V (10 mA max), • Serial interface RS232.
to supply external devices. • 12/14 bit digital controller.

54 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Control Options PQ (cont.)
For basic pump details,
see general Installation Dimensions.

Pump Dimensions with


PQD0 Control A
Proportional
Options illustrated: control valve
24 25 = PQ (displacement adjust-
ment via proportional valve)
26 = D (CETOP 3 proportional
valve KBS-3 with OBE)
30 = 0 (no additional function)
G
35 = 0 (no pilot oil filter)
36 = 0 (no venting valve)

Pump Overall Dimensions


with Control PQD0 (mm)
Pump Size A G
130 446 350
180 446 350
250 461 394
360 475 394
500 520 426
750 562 428

A – System port
B Inlet port
L1, L2 – Drain port
L3 – Vent port for vertical mounting
L3.1, L8 – Air bleed port
L5 – Oil filling plug
MA – Gauge port, system pressure
ML – Gauge port, case pressure
PSt1 – Pilot pressure inlet port
MSt – Pilot pressure gauge port

1 – Basic pump
2 – Connection plate for PQ-control
2.1 – Pilot pressure relief valve
3 – Proportional control valve
4 – Pressure sensor (optional)

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 55
Control Options ES
Available to special order only.

General Description A potentiometer for stepless with the result that once the No Pressure/Power
This unit is used for flow adjustment and/or position control is specified and built, Limiter possible!
adjustment. It has a 3-phase monitoring is also available. response time are not variable in
electric servo-motor, worm-gear Response times from zero to operation. Explosion Protection
and a switchbox with 4 or maximum depend on the ratio versions are also available.
(optional) 8 limit switches for selected and on the (fixed)
different positions. speed of the servo-motor,

Pump Dimensions with Options illustrated:


ESN...A2 Control 24 25 = ES (electric motor
adjusted displacement)
26 = N (electric motor,
For other options and sizes,
please contact Eaton Technical medium response)
37 = A (4 limit switches)
Support for individual pump
38 = 2 (motor with brake, IP54)
drawings.

Theoretical Response Time for Maximum Displacement


Response time from 0 to 100% displacement can vary between
5s and 70s depending on pump size, motor type and supply
voltage. Contact Eaton Technical Support for details.

428
292 595
177 369

Dimensions shown for PVW 250 only.

56 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Control Options ES (cont.)
Available to special order only.
For basic pump details,
see general Installation Dimensions.

Pump Dimensions with


ESN...A2 Control (cont.)

For other options and sizes,


please contact Eaton Technical
Support for individual pump
drawings.

A – System port
B – Inlet port
L1, L2 – Drain port
L3 – Vent port for vertical mounting
L3.1, L8 – Air bleed port
L5 – Oil filling plug
MA – Gauge port, system pressure
ML – Gauge port, case pressure

1 – Basic pump
2 – Electric Motor for ES-control

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 57
General Dimensions
PFW 250 Pumps
Options illustrated:
12 = R (clockwise rotation)
14 15 = 00 (no thru drive)
18 19 = 01 (ISO keyed shaft)
22 = 0 (no yoke position indicator)
24 25 = 00 (without control)

0 52 230 365
250
A MA*
117
8 20
L3*
L1* L2
L3.1* 160 L1*
321
Ø25 CW
0
50 285
69 +0.2
75 L1* L2*
Centrebore 115 125
DIN 332-D
M20 L2*
4 x M16-18 deep
22
105 80 196 B
234
X

L8* L5*

ML*
A
m6
Ø65

Ø200 f7

18 h9

200
L3.1*
426
238 L3*
448

A – System pressure port ISO 6162-2 P38M (SAE J518 code 62, 11/2", 6000 psi) L3.1 – Port G1/8"
B – Inlet pressure port ISO 6162-1 P89M (SAE J518 code 61, 31/2", 500 psi) L5 – Oil filling plug 11/16"-12 UNF-2B
L1 – Drain port 15/8"-12 UNF-2B (depending on mounting position, use upper port) L8 – Air bleed port G1/4"
L2 – Drain port G11/4" (depending on mounting position, use upper port) MA – System pressure gauge port G1/4"
L3 – Vent port for vertical mounting G3/8" (shaft upward) ...* – Connection with plug

58 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Shaft and
Mounting Options
PFW 250 Pumps

Mounting Flanges and Shaft Ends

Ø44.42-44.43 (1 3/4")
92 79 11.1h9
W62x1.25x10a 9 20 9 20
DIN 5480
7.5
Ø31
2.5 Ø25 Ø165.1-0.05 6
0
Ø200f7 49.3+ 0.2

Centrebore 28
DIN 332-D
M20 Centrebore 67
42 DIN 332 D
45º 45º
80 22 M12 45º 45º 22
88.388 88.388
234 112.25 112.25
270
ISO splined shaft: 10 11 = 07 & 18 19 = 02
SAE E keyed shaft: 10 11 = 0E & 18 19 = E1

8/16DP-13T 84 Ø50.8m6 (2")


ANSI B92.1 8 20 12.7h9
100
9 20
7.5
Ø31 56.3+ 0.2
3 Ø35
0
Ø165.1-0.05 6
Ø177.8-0.05
28
Centrebore
Centrebore 67 DIN 332 D
DIN 332-D 45º M20
45º 22 42
M12 97
112.25 112.25 45º 22
270 45º
123.75 123.75
SAE E splined shaft: 10 11 = 0E & 18 19 = E2 290

SAE E keyed shaft: 10 11 = 0F & 18 19 = F1

88
8/16DP-15T 8 20
ANSI B92.1 Main Ports
0
Ø35
69.8 M16-40 deep
3 36.7 M16-30 deep
Ø177.8-0.05 Ø9
Ø3 0
8
Centrebore
DIN 332 79.4 120.7
5
/8"-11UNC-2B 36
76
45º 45º 22
123.75 123.75
290
Port A Port B
SAE F splined shaft: 10 11 = 0F & 18 19 = F2 View X

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 59
General Dimensions
PFW 360 Pumps
Options illustrated:
12 = R (clockwise rotation)
14 15 = 00 (no thru drive)
18 19 = 01 (ISO keyed shaft)
22 = 0 (no yoke position indicator)
24 25 = 00 (without control)

0 52 230 381
250
A MA*
117
8 20
L3*
L1* L2
160 L1*
L3.1*
Ø25 CW 321
0
50 285
69 +0.2
75 L1* L2*
Centrebore 115
DIN 332-D M20 125
L2*
4 x M16-18 deep
228 22
105 80 196 B 234
X

L8* L5*

A
Ø65 m6

Ø200 f7

18 h9

L3.1*
200
426
238 L3*
448

A – System pressure port ISO 6162-2 P38M (SAE J518 code 62, 11/2", 6000 psi) L3.1 – Port G1/8"
B – Inlet pressure port ISO 6162-1 P89M (SAE J518 code 61, 31/2", 500 psi) L5 – Oil filling plug 11/16"-12 UNF-2B
L1 – Drain port 15/8"-12 UNF-2B (depending on mounting position, use upper port) L8 – Air bleed port G1/4"
L2 – Drain port G11/4" (depending on mounting position, use upper port) MA – System pressure gauge port G1/4"
L3 – Vent port for vertical mounting G3/8" (shaft upward) ...* – Connection with plug

60 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Shaft and
Mounting Options
PFW 360 Pumps

Mounting Flanges and Shaft Ends

Ø44.42-44.43 (1 3/4")
92 79 11.1h9
W62x1.25x10a 9 20 9 20
DIN 5480
7.5
Ø31
2.5 Ø25 Ø165.1-0.05 6
0
Ø200f7 49.3+ 0.2

Centrebore 28
DIN 332-D
M20 Centrebore 67
42 DIN 332 D
45º 45º
80 22 M12 45º 45º 22
88.388 88.388
234 112.25 112.25
270
ISO splined shaft: 10 11 = 07 & 18 19 = 02
SAE E keyed shaft: 10 11 = 0E & 18 19 = E1

8/16DP-13T 84 Ø50.8m6 (2")


ANSI B92.1 8 20 12.7h9
100
9 20
7.5
Ø31 56.3+ 0.2
3 Ø35
0
Ø165.1-0.05 6
Ø177.8-0.05
28
Centrebore
Centrebore 67 DIN 332 D
DIN 332-D 45º M20
45º 22 42
M12 97
112.25 112.25 45º 22
270 45º
123.75 123.75
SAE E splined shaft: 10 11 = 0E & 18 19 = E2 290

SAE E keyed shaft: 10 11 = 0F & 18 19 = F1

88
8/16DP-15T 8 20
ANSI B92.1 Main Ports
0
Ø35
69.8 M16-40 deep
3 36.7 M16-30 deep
Ø177.8-0.05 Ø9
Ø3 0
8
Centrebore
DIN 332 79.4 120.7
5
/8"-11UNC-2B 36
76
45º 45º 22
123.75 123.75
290
Port A Port B
SAE F splined shaft: 10 11 = 0F & 18 19 = F2 View X

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 61
General Dimensions
PFW 500 Pumps
Options illustrated:
12 = R (clockwise rotation)
14 15 = 00 (no thru drive)
18 19 = 01 (ISO keyed shaft)
22 = 0 (no yoke position indicator)
24 25 = 00 (without control)l

0 52 185 409 337.5


A
115
9 25
L2 L1*

L3.1*
190 CW 409
L3*
115 L1*
18
356
74.5 +0.2
Ø31
5
18 115
Centrebore L2* 160 L1* L2*
DIN 332-D 166
M20

4 x M16-29 deep
300 26
105 90 200 B
X 310

MA*

A
20 h9

Ø250 f7

Ø70 m6

180 484
328 506

A – System pressure port ISO 6162-2 P51M (SAE J518 code 62, 2", 6000 psi) L3 – Vent port for vertical mounting G1/4" (shaft upward)
B – System pressure port ISO 6162-1 P127M (SAE J518 code 61, 5", 500 psi) L3.1 – Port G1/4"
L1 – Drain port 15/8"-12 UNF-2B (depending on mounting position, use upper port) MA – System pressure gauge port G1/4"
L2 – Drain port G11/2" (depending on mounting position, use upper port) ...* – Connection with plug

62 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Shaft and
Mounting Options
PFW 500 Pumps

Mounting Flanges and Shaft Ends

141 20
106 16
106
10 25 104.5
W80x3.25x10a
DIN 5480
Ø45

315.000 A Ø36 5
2 Ø 314.919 0 Ø40
Ø250f7

Ø315
Centrebore C/bore DIN 332-D
DIN 332-D M20 42
M20 W80x3.25x10a
DIN 5480

42 45º
95 45º
26

22.5
º
111.37 111.37 8x45º
300 380

ISO splined shaft: 10 11 = 08 & 18 19 = 02 ISO special splined shaft: 10 11 = 09 & 18 19 = 05

Main Ports

92.1 M16-20 deep


44.5 M20-25 deep
Ø5 Ø1
0 25

96.8 152.4

Port A Port B
View X

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 63
General Dimensions
PFW 750 Pumps
Options illustrated:
12 = R (clockwise rotation)
14 15 = 00 (no thru drive)
18 19 = 02 (ISO splined shaft)
22 = 0 (no yoke position indicator)
24 25 = 00 (without control)

0 199 496 339


115 A
9 32

L2 L1*

CW
190
125 L1*
Ø31 417
5
356

Centrebore
115 L2* L2*
DIN 332-D L1*
M20 160 166

4 x M16-29 deep 300 26


105 102 255 B 320
X

462

L3*

MA*

W90x3x28x9g
DIN5480
A

Ø250 f7

180
539
328 561

A – System pressure port ISO 6162-2 P51M (SAE J518 code 62, 2", 6000 psi) L3 – Vent port for vertical mounting G1/4" (shaft upward)
B – System pressure port ISO 6162-1 P127M (SAE J518 code 61, 5", 500 psi) MA – System pressure gauge port G1/4"
L1 – Drain port 15/8"-12 UNF-2B (depending on mounting position, use upper port) ...* – Connection with plug
L2 – Drain port G11/2" (depending on mounting position, use upper port)

64 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Shaft and
Mounting Options
PFW 750 Pumps

Mounting Flanges and Shaft Ends Main Ports

ISO splined shaft: 10 11 = 08 & 18 19 = 02


as illustrated on the previous page is the only arrangement suitable for
Hydrokraft pumps PFW 750. 92.1 M16-20 deep
44.5 M20-25 deep
Ø1
25
Ø5
0

96.8 152.4

Port A Port B
View X

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 65
Thru-Drive Options
130 and 180 Series
All thru-drives accept DIN ISO 3019-2 (SAE J744) mounting
interface. Other thru-drive interfaces available on request.
For basic pump details, see general Installation Dimensions.

Option illustrated:
14 15 = 0A (SAE A)
2 x M10 15
9T 16/32 DP

82.61
Ø 82.58

9
28
106.4 34

Option illustrated:
14 15 = 0B (SAE B)
2 x M12 28
13T 16/32 DP

101.65
Ø 101.62

15
28
89.8 46
146

Option illustrated:
14 15 = 0C (SAE C)
14T 12/24 DP

2 x M16 43

2 x M12 25 127.05
Ø 127.02

13
24
114.5 43
181 63

66 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Thru-Drive Options
250 and 360 Series
All thru-drives accept DIN ISO 3019-2 (SAE J744) mounting
interface. Other thru-drive interfaces available on request.
For basic pump details, see general Installation Dimensions.

Option illustrated:
14 15 = 0A (SAE A)

9T 16/32 DP

82.61
Ø 82.58

2 x M10 18

7
106.4 28
38

Option illustrated:
14 15 = 0B (SAE B)

13T 16/32 DP

101.65
Ø 101.62

2 x M12 28

16
89.8 28
146 48

Option illustrated:
14 15 = 0C (SAE C)
14T 12/24 DP
4 x M12

127.05
Ø 127.02
2 x M16 45

12
114.5 31
45
181
62

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 67
Thru-Drive Options
500 Series
All thru-drives accept DIN ISO 3019-2 (SAE J744) mounting
interface. Other thru-drive interfaces available on request.
For basic pump details, see general Installation Dimensions.

Option illustrated:
14 15 = 0A (SAE A)

2 x M10 20
9T 16/32 DP

82.61
Ø 82.58

14
106.4 18
35

Option illustrated:
14 15 = 0B (SAE B)

13T 16/32 DP
2 x M12 20

101.65
Ø 101.62

12
19
35
146 51

Option illustrated:
14 15 = 0C (SAE C)
4 x M12

14T 12/24 DP
2 x M16 28

127.05
Ø 127.02

16.5
28
114.5
68
181

68 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Thru-Drive Options
750 Series
All thru-drives accept DIN ISO 3019-2 (SAE J744) mounting
interface. Other thru-drive interfaces available on request.
For basic pump details, see general Installation Dimensions.

Option illustrated:
14 15 = 0A (SAE A)

2 x M10 20 9T 16/32 DP

82.61
Ø 82.58

18
106.4 19
40

Option illustrated:
14 15 = 0B (SAE B)

13T 16/32 DP

101.65
Ø 101.62

2 x M12 20

12
14
146 35
46

Option illustrated:
14 15 = 0C (SAE C)

4 x M12
14T 12/24 DP

2 x M16 22
127.05
Ø 127.02

13
15
22
114.5
46
181 63

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 69
Swash Angle and
Flow Direction

CW CCW

Optically indicated
swash angle
+V -V

A A

Pressure control setting

70 EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016
Personal Notes

Eaton
Hydraulics Group EMEA
Hydrokraft plant
Am Joseph 16
D-61273 Wehrheim
Germany
Tel. +49 (0)6081103-324/-266/-235
Fax. +49 (0)6081103-342

EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM003-EN2 August 2016 71
Eaton Eaton Eaton
Hydraulics Group USA Hydraulics Group Europe Hydraulics Group Asia Pacific
14615 Lone Oak Road Route de la Longeraie 7 Eaton Building
Eden Prairie, MN 55344 1110 Morges 4th Floor, No. 3 Lane 280 Linhong Rd
USA Switzerland Changning District
Tel: 952-937-9800 Tel: +41 (0) 21 811 4600 Shanghai 200335
Fax: 952-294-7722 Fax: +41 (0) 21 811 4601 China
www.eaton.com/hydraulics Tel: (+86 21) 5200 0099
Fax: (+86 21) 5200 0400

© 2016 Eaton Corporation


All Rights Reserved
Document No. V-PUPI-TM003-EN2
August 2016

You might also like