Download as doc, pdf, or txt
Download as doc, pdf, or txt
You are on page 1of 12

Test Report

Part Name:ANTENNA AMPLIFIER AM/FM

Test Item: Electrical Performance Test

Quality Department
Content
1. Test results for Electrical Parameters ………………………………….P3
2. Pictures for Electrical Parameters …………………………………… …………. P
4

Page 1 of 11
Test Report
ASM ANTENNA
Name Model
AMPLIFIER AM/FM1

Manufacture

Sample Qty 5 pcs Test place Test Lab

Date

Test Temperature: Relative humidity: Atmospheric


environmental (25~28)℃ 54%~72% pressure:101.3kPa

Test project Gain、Operating Current、AM IM2、FM1 IM3,Noise voltage。

AM/FM Specification
Test Standard
Mobile Communication Antenna General Tech. Standard GB9410-88

E5062A Vector Network Analyzers


N9000A Spectrum Analyzers
Test
2026B Signal Source
Equipment
WYK-303 D. C. Constant Power
NB973A Noisy Analyzer

Summary all electrical performance can meet the requirements.

Conclusion Pass

Note N/A

Checked By: Audited By: Approved By:

Page 2 of 11
Test result for Electrical Parameters
Test Results
No# Item Tech. Requirement Unit Conclusion
1# 2# 3# 4# 5#

520KHz -8.94 -9.14 -9.11 -9.04 -9.25


(-5±5)@ AM:
1115KHz dB -8.57 -8.60 -8.67 -8.64 -8.75 Pass
(520-1710)KHz
1710KHz -8.74 -8.69 -8.76 -8.75 -8.78
1 Gain
88MHz 7.17 6.89 6.85 6.78 7.44
(7±2)@ FM:
98MHz dB 7.54 7.36 7.36 7.28 7.67 Pass
(88-108)MHz
108MHz 7.97 7.96 8.08 8.00 7.85

2 VSWR <4.5 / 1.19 1.21 1.19 1.19 1.21 Pass

3 Operating Current ≤90 mA 68 68 68 68 68 Pass

4 AM:IM2 ≥50 dBuV 59.67 61.12 58.88 56.25 59.57 Pass

FM:IM3 88 69.09 68.97 68.64 68.80 69.03 Pass

5 FM:IM3 98 ≥60 dBuV 68.68 68.38 67.76 68.01 68.45 Pass

FM:IM3 108 69.22 70.03 69.90 69.45 69.54 Pass

Noise voltage
6 ≤-6 dBuV -10.94 -10.92 -11.028 -11.037 -11.007 Pass
AM
Noise voltage
7 ≤-5 dBuV -5.27 -5.304 -5.195 -5.199 -5.183 Pass
FM

8 AGC <99 dBuV 94 94 94 94 94 Pass

Equipments and devices fro Test

Item Name Model No# Validate date

1 Vector Network Analyzers E5062A

2 Spectrum Analyzers N9000A

3 Signal Source 2026B

4 D. C. Constant Power WYK-303

MY45270926+
5 Noisy Analyzer
MY44421125

Pictures for Electrical Parameters


AM Gain test

Page 3 of 11
AM Gain test connection diagram 1#

2# 3#

4# 5#

To be continue
FM Gain test
FM Gain, standing wave test connection 1#

Page 4 of 11
2# 3#

4# 5#

To be continue
AM IM2 Test

Page 5 of 11
AM:IM2;Two order intermodulation testing connection 1#

2# 3#

4# 5#

To be continue
FM (IM3 88)IM3 Test

Page 6 of 11
FM: Three order intermodulation testing connection 1#

2# 3#

4# 5#

To be continue

Page 7 of 11
FM(IM3 98)IM3 Test
FM: Three order intermodulation testing connection 1#

2# 3#

4# 5#

To be continue

Page 8 of 11
FM(IM3 108)IM3 Test
FM: Three order intermodulation testing connection 1#

2# 3#

4# 5#

Page 9 of 11
To be continue
AM Noise Voltage Test
AM Noise voltage test connection diagram 1#

2# 3#

4# 5#

Page 10 of 11
To be continue
FM Noise Voltage Test
FM Noise voltage test connection diagram 1#

2# 3#

4# 5#

Page 11 of 11