Test Report

Part Name:ANTENNA AMPLIFIER DAB Ⅲ

Test Item: Electrical Performance Test

Quality Department
Content
1. Test results for Electrical Parameters ………………………………….P3
2. Pictures for Electrical Parameters …………………………………… …………. P
4

Page 1 of 11
Test Report
ANTENNA
Name Model
AMPLIFIER DAB Ⅲ

Manufacture

Sample Qty 5 pcs Test place Test Lab

Date

Test Temperature: Relative humidity: Atmospheric


environmental (25~28)℃ 54%~72% pressure:101.3kPa

Test project Gain、Operating Current、DAB IM3,Noise voltage

DAB Specification
Test Standard
Mobile Communication Antenna General Tech. Standard GB9410-88

E5062A Vector Network Analyzers


N9000A Spectrum Analyzers
Test
2026B Signal Source
Equipment
WYK-303 D. C. Constant Power
NB973A Noisy Analyzer

Summary all electrical performance can meet the requirements.

Conclusion Pass

Note N/A

Checked By: Audited By: Approved By:

Page 2 of 11
Test result for Electrical Parameters
Test Results
No# Item Tech. Requirement Unit Conclusion
1# 2# 3# 4# 5#

174MHz 13.12 14.30 13.42 12.93 14.03


(14±2)@ DAB:
1 Gain 207MHz dB 13.07 13.54 13.49 13.26 13.50 Pass
(174-240)MHz
240MHz 14.17 13.94 14.99 14.45 13.82

2 VSWR <4.5 / 1.49 1.35 1.48 1.47 1.35 Pass

3 Operating Current ≤80 mA 35 36 36 35 36 Pass

DAB:IM3 174 62.42 66.87 67.05 66.36 65.68 Pass

4 DAB:IM3 207 ≥60 dBuV 68.41 67.73 68.36 68.26 68.48 Pass

DAB:IM3 240 68.63 69.38 69.4 68.88 69.26 Pass

Noise voltage DAB


5 ≤1 dBuV -0.71 -0.74 -0.9 -0.81 -0.55 Pass

Equipments and devices fro Test

Item Name Model No# Validate Date

1 Vector Network Analyzers E5062A

2 Spectrum Analyzers N9000A

3 Signal Source 2026B

4 D. C. Constant Power WYK-303

MY45270926+
5 Noisy Analyzer
MY44421125

Pictures for Electrical Parameters


Page 3 of 11
DAB Ⅲ Gain test
Gain, standing wave test connection 1#

2# 3#

4# 5#

To be continue
DAB Ⅲ (IM3 174)IM3 Test

Page 4 of 11
Three order intermodulation testing connection
1#
diagram

2# 3#

4# 5#

To be continue

Page 5 of 11
DAB Ⅲ (IM3 207)IM3 Test
Three order intermodulation testing connection
1#
diagram

2# 3#

4# 5#

Page 6 of 11
To be continue
DAB Ⅲ (IM3 240)IM3 Test
Three order intermodulation testing connection
1#
diagram

2# 3#

4# 5#

Page 7 of 11
To be continue
DAB Ⅲ Noise voltage Test
Noise voltage test connection diagram 1#

2# 3#

4# 5#

Page 8 of 11