FEMTO LDV Z6
The ultimate femto-technology for the whole anterior segment
Corneal surgery
Specifications – Intracorneal Rings
Presbyopia1-tailored treatment:
• Pre-programmed trajectories for all ring segments
• Post-LASIK treatments – highly precise pocket • Full flexibility: 1 or 2 individual tunnels, or
resection below an existing flap 1 complete 360° tunnel
• Tailored pocket software for intrastromal inlays • Tailored procedures: different dimensions and
depths for each tunnel possible
Treatment of astigmatism and other pathological corneal • Maximal resection depth: 850 µm
deformations with your femtosecond laser:
Specifications – Intrastromal Pockets
• Tunnel resections for intracorneal ring segments
• Easy insertion thanks to complete resection • Pre-programmed trajectories for most inlays
• Manual option for customization of the trajectory
• Secondary tunnel option
ZIEMER IS THE FEMTO-TECHNOLOGY COMPANY OF TODAY,
TOMORROW AND THE FUTURE
Therapeutic procedures
Specifications – Keratoplastic
• Penetrating Keratoplasty
• Lamellar Keratoplasty:
(D)ALK preparation of patient and donor resection
DSEK ultra-thin lamellas possible
• Flexible geometry: round and oval resection
• Customizable angled edge
• Adjustable pulse energy possible (depending
on resection depth and cornea quality)
• Max resection depth: 850 µm
Z-LASIK • • •
Z-LASIK Z • •
Anterior Capsulotomy •
Lens Fragmentation •
Ziemer Ophthalmic Systems AG Ziemer USA, Inc. Ziemer Ophthalmology (Deutschland) GmbH Issue Date: 2015-07
a Ziemer Group Company a Ziemer Group Company a Ziemer Group Company REF 510.931.008
Allmendstrasse 11 620 E. Third Street Im Hausgrün 15 Doc. No.: FL5940-0518-04
2562 Port, Switzerland Alton, Illinois 62002, USA 79312 Emmendingen, Germany
Phone +41 32 332 70 70 Phone +1 618 462 9301 Phone +49 7641 9333860
innovation@ziemergroup.com usa @ ziemergroup.com info-deutschland @ ziemergroup.com
www.ziemergroup.com
www.femtoldv.com
The FEMTO LDV Z2, Z4 and Z6 are FDA cleared and CE marked and available for immediate delivery. The FEMTO LDV Z8 is CE marked but not yet cleared by the FDA for the use in the
United States. For some countries, availability may be restricted due to local regulatory requirements; please contact Ziemer for details.
1 The creation of a corneal pocket is part of a presbyopia intervention. Availability of related corneal inlays and implants according to policy of the individual manufacturers and
regulatory status in the individual countries.