Installation Procedure for 2300 Series Scanners

Installation Procedure for 2300 Series Scanners


bk3000
bk5000
IMPORTANT:
This procedure must be carried out only by BK service personnel or their authorised
representatives. The procedure covers unpacking and set-up of the system including
connecting to the power outlet and a possible network connection.

All scanners leaving the factory are configured for mains voltage 115/220V, European TV
standard (PAL) 50Hz - 625 lines and English language. The main voltage does not have to be
changed as the power supply accepts 115 and 220V

1 Necessary tools ............................................................................................................................... 1


2 Unpacking the scanner .................................................................................................................... 2
3 Mount the monitor ........................................................................................................................... 3
4 Mount the Cable holder ................................................................................................................... 9
5 Mounting the Endo Transducer Holder UA2357 (optional) ........................................................... 10
6 Installation of integrated printer UA2353 - UP-D711MD (optional) ............................................... 11
7 Installation of Printer Start-Up kit UA2359 - UP-D898MD (optional) ............................................. 14
8 Connecting mains cable and Wi-Fi USB module .......................................................................... 20
9 Changing Language, and System Time ........................................................................................ 22
10 Functionality and Safety test ......................................................................................................... 24

1 Necessary tools

Tool/document Purpose
Screw driver Torx #10 For mounting the Monitor or Printer(option)
Screw driver Torx #20 For mounting the Cable holder
Screw driver Torx #25 For mounting the Monitor or Endo transducer holder(option)
Screw driver PZ0 For removing screws on Sony integrated printer
Service Manual for 2300 - SM34584 Checking Procedure and Safety Test

The screw drivers should be


slim, it is not possible to use
short bits, see figure

IG35362 16-01293rev04 1 of 25
Installation Procedure for 2300 Series Scanners

2 Unpacking the scanner

2.1 Remove the protective packing material from the scanner


(this drawing can also be used as reference for repackaging the scanner)

Monitor

2 of 25 IG35362
Installation Procedure for System 2300

3 Mount the monitor

3.1 Slide down the monitor on the monitor bracket

IG35362 3 of 25
Installation Procedure for 2300 Series Scanners

3.2 Mount 3 screws while holding the monitor in upright position

4 of 25 IG35362
Installation Procedure for System 2300

3.3 Tilt down the monitor

3.4 Mount the Monitor HDMI and power cable

IG35362 5 of 25
Installation Procedure for 2300 Series Scanners

3.5 Mount the screw holding the cable relief/grounding and the two lowest screws

6 of 25 IG35362
Installation Procedure for System 2300

3.6 Mount the back cover

3.7 Push the cover down while mounting the right screw

IG35362 7 of 25
Installation Procedure for 2300 Series Scanners

3.8 Tilt the monitor to upright position and mount the second screw for the back cover

8 of 25 IG35362
Installation Procedure for System 2300

4 Mount the Cable holder

4.1 If mounted remove the two M4x8 screws using a Torx #20 screwdriver

4.2 Place the cable holder and mount it with the two M4x35 using a Torx #20 screwdriver

IG35362 9 of 25
Installation Procedure for 2300 Series Scanners

5 Mounting the Endo Transducer Holder UA2357 (optional)

5.1 If mounted remove the two M5x8 5.2 Position the Endo Transducer Holder as
screws using a Torx #20 screwdriver shown below

5.3 Mount the holder using the two M5x30 5.4 Mounted Endo Transducer Holder
screws

10 of 25 IG35362
Installation Procedure for System 2300

6 Installation of integrated printer UA2353 - UP-D711MD (optional)

6.1 Dismount screw Torx 10


Use Key from package or a screwdriver 6.2 Pull out Cover Drawer

6.3 Dismount 2 screws Torx 10 6.4 Cable through slot in Cover drawer.
Remount 2 screws again

6.5 Push back the Cover drawer and 6.6 Mount Chassis with 3 screws M3x8
remount screw Torx10 from package

IG35362 11 of 25
Installation Procedure for 2300 Series Scanners

12 of 25 IG35362
Installation Procedure for System 2300

6.7 Connect printer 6.8 Push in printer

6.9 Mount four screws M3x8 Torx 10 from


package

IG35362 13 of 25
Installation Procedure for 2300 Series Scanners

7 Installation of Printer Start-Up kit UA2359 - UP-D898MD (optional)

7.1 Put the Printer upside down 7.2 Fix it to the shelf using the 4 screws
from the package

7.3 Place the shelf on the column

14 of 25 IG35362
Installation Procedure for System 2300

The USB cable for the Printer need to be connected to the scanner either on the front or on the
back (behind the Lid) For a permanent mounting it is suggested to mount it as shown below
where it is connected to the front disconnecting the cable for the internal printer

7.4 Remove the back lid by removing the screw and pull the cover a little from each other so
that the lid can be removed

IG35362 15 of 25
Installation Procedure for 2300 Series Scanners

7.5 Remove the two screws at the front of 7.6 Remove the two screws at the bottom
the left side cover

7.7 Carefully slide off the cover and turn it so you can remove the two screws holding the
power switch

16 of 25 IG35362
Installation Procedure for System 2300

7.8 Dismount the screw Torx 10 here: 7.9 Pull out the cables for the internal printer

7.10 Loosen the USB cable from the shroud

7.11 Identify which USB cable that goes from the internal printer shroud to the Engine

IG35362 17 of 25
Installation Procedure for 2300 Series Scanners

7.12 Disconnect the USB cable that goes to the 7.13 Connect the cable for the External USB
Internal Printer printer to the Engine connector where you
just removed a cable

7.14 Mount the Power Splitter box on the bottom of the Scanners Series 2300 engine, with two
screws (3x5 mm) by using a TX10 screw driver
st
NOTE: Splitter box can be mounted on Scanners Series 2300 system from produced after 1
November 2015.

Power Splitter box

1m long to printer

0,5m long to
2300 engine

18 of 25 IG35362
Installation Procedure for System 2300

7.15 Connect Power output cables from splitter box to Scanners Series 2300 engine and to printer.
Connect the USB cable to the printer

7.16 Mount Left side Enclosure reversing the steps 7.7 – 7.4

IG35362 19 of 25
Installation Procedure for 2300 Series Scanners

8 Connecting mains cable and Wi-Fi USB module

Connectors on the back of the Scanner – connect the mains cable and other cables if needed

Do not use connectors marked


here
(they are for factory testing use)

Composite Out (RCA/Phono)

USB 3 (Blue plugs)

LAN/(DICOM1)

DVI-I

USB 2

Super-Video out

Audio out

Audio In

Main Power Switch

Mains input

1
To comply with IEC60601-1 the network connection to the scanner must be isolated from the hospital network (Medical 230 V isolation). If
the hospital network does not fulfil this the network isolator DP0925 must be used

20 of 25 IG35362
Installation Procedure for System 2300

Mount the USB WI-Fi behind the rear door as showed below

IG35362 21 of 25
Installation Procedure for 2300 Series Scanners

9 Changing Language, and System Time

9.1 Turn on the scanner and wait for it to complete the boot up sequence

9.2 Click on the Image tab

9.3 Then Click on Advanced

9.4 Click on Customize

9.5 Select System

22 of 25 IG35362
Installation Procedure for System 2300

9.6 Select the Language

9.7 Click Adjust Date and Time... to adjust to local time – a warning will come up:

9.8 Click OK

9.9 Select the correct Time Zone and then adjust the time if necessary

IG35362 23 of 25
Installation Procedure for 2300 Series Scanners

9.10 Click OK

9.11 Restart the scanner by turning it off and then on

10 Functionality and Safety test

10.1 Check the system according to the Getting Started Guide on the Service Web

10.2 Perform a safety test of the system according to the service manual

24 of 25 IG35362