Annexure-5.1 Brief Technical Features of Power Generating Equipment Turbine Generator & Auxiliaries

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Detailed Project Report

For 2x300 MW Coal Based TPP


at Vilathikulam Tk.,
Thoothukudi Dist. Tamil Nadu

Job No: 13Z01

ANNEXURE- 5.1
BRIEF TECHNICAL FEATURES
OF POWER GENERATING EQUIPMENT

1. TURBINE GENERATOR & AUXILIARIES:

Type : Single reheat multi-cylinder tandem


compound, condensing steam turbine
directly driving a 3000 rpm, 2-pole,
50Hz, electric power generator.

Nominal Capacity : 300,000 KW at 33 °C condenser cooling


water temperature.

Normal Operating Frequency Range : 47.5 to 51.5 Hz

Inlet Steam Parameters: -


Main Steam Hot Reheat
Pressure, kg/cm2 (abs.) : 170 32.83
Temperature, °C : 537 537
Steam flow at MCR T/hr. (approx.) : 910 753.03

Exhaust Pressure : ~76 mm of Hg (abs.)

Steam Extractions : CRH + 6 Nos. stages from IP and LP


turbines for condensate/feed water
heating.

Type of governing : Mechanical and electro-hydraulic.

Turbine HP-LP bypass system : Capacity : 60% at MCR

Condensing Equipment : Shell and tube type surface condenser,


two-pass divided flow design operating
on recirculating cooling water with
cooling towers. Temperature
differenttial 10°C.

2x300MW-TPP-DPR-PEL ANNEXURE-5.1
5.1-1
Detailed Project Report
For 2x300 MW Coal Based TPP
at Vilathikulam Tk.,
Thoothukudi Dist. Tamil Nadu

Job No: 13Z01

Regenerative feed heating arrangement : Three stages of LP heaters (shell and


tube design), one spray/tray type direct
contact deaerating heater and two stages
of HP heaters (shell and tube design).

Boiler feed water pumps : 3 x 50% capacity Electric Motor driven


horizontal, centrifugal BFP and driven
by 6.6 kV motors respectively.

Condensate extraction pumps : 3 x 50% capacity vertical, centrifugal


CAN type construction electric motor
driven.

Generator : 300000 kVA output at 0.85 power


factor (lagging) 3 pH, 50 Hz and 20 kV
voltage.

2. STEAM GENERATOR & AUXILIARIES:

Type : Pulverized fuel, natural circulation, two-


pass, balanced draft, semi-outdoor type,
pulverized coal fired unit with
associated auxiliaries suitable for both
constant and sliding pressure operation.

Nominal Capacity : 1010.1 Tones/Hr (max.)

Nominal Outlet Steam Parameters at BMCR :-

Main Steam Hot Reheat

Pressure (kg/cm2) : 179 *


Temperature, °C : 540 540
Steam flow, T/hr. (approx.) : 1010.1 753.03

- Steam temp. Control range : 60-100% BMCR

- Super heater/Re-heater : Spray Water and/or burner control.


temperature control

2x300MW-TPP-DPR-PEL ANNEXURE-5.1
5.1-2
Detailed Project Report
For 2x300 MW Coal Based TPP
at Vilathikulam Tk.,
Thoothukudi Dist. Tamil Nadu

Job No: 13Z01

Nominal Air Heaters Capacity : 2 x 60% regenerative or 100% tubular


type.

Draft Fans : 2 x 60% capacity axial flow forced draft


fans with variable blade pitch control or
centrifugal type with inlet vane control.

2 x 60% capacity centrifugal induced


draft fans with variable speed fluid
coupling.

2 x 60% capacity centrifugal Primary


fans with inlet vane control.

Electrostatic Precipitator : Multi-field, multi-path electrostatic type


suitable for limiting dust emission
below 50 mg/Nm3 at outlet with one
field out of service with worst coal at
100% BMCR.

Pulverizing Mills : Slow speed bowl or ball and race


type in **N+1 configuration.

Coal Firing System : Direct suspended firing with state-of-


the-art low NOX burners giving stable
fire between 40-100% BMCR without
oil firing.

Start-up/auxiliary fuel : Light Diesel Oil for cold start and for
support (capacity up to 10% BMCR).
Heavy Fuel Oil (HFO) for flame support
upto 30 % of BMCR.
Note : * Vendor to specify.

Ash removal : Bottom Ash : Disposal to ash dyke in


slurry form.

Fly Ash : In dry condition through


vacuum and by
pressurized air conveying
2x300MW-TPP-DPR-PEL ANNEXURE-5.1
5.1-3
Detailed Project Report
For 2x300 MW Coal Based TPP
at Vilathikulam Tk.,
Thoothukudi Dist. Tamil Nadu

Job No: 13Z01

for transportation to silos


and final disposal by
truck for utilization or
disposal in slurry form in
case of emergency.

**Note : N-denotes the number of mills at BMCR with design coal and 90% mill loading.

2x300MW-TPP-DPR-PEL ANNEXURE-5.1
5.1-4