Data sheet

N° : Date : 17 déc. 2018

Induction motor with options


4P FLSHT 280SD 75kW IFT/IE2 400°C - 120min B30 380D/400D/415D/690Y 50Hz -
IC418 ;

Utilisation : Environment Smoke Extract ; Ambiance High temperature ; Finition - ; Zone Smoke extract ; Type of protection 400°C - 120min ;
Centrifugal applications ; Ambient temperature -16 +40 °C ; Maximum altitude 1000 m.
Motor caracteristics : Cast iron housing ; Cast iron DE endshield ; Cast iron NDE endshield.

Motor definition
Protection type 400°C - 120min Application Centrifugal applications
Generation code IFT Main voltage (V) 400
Efficiency class IE2 Connection DY
Number of network phases 3 Motor winding (V) 380D/400D/415D/690Y
Number of speed Rated Frequency (Hz) 50
Polarity 4P Operation position B3
Motor serie FLSHT Index of protection IP55
Frame size (mm) 280 Index of cooling IC418
Lenght code SD Insulation class H
HS rated power (kW) 75.000 Finish -
- Moment of inertia J (kg.m2) 0.8500000
Rated speed (min-1) 1484 Motor weight (kg) 600.0
Maximum mechanical speed (min-1) 2160

Common definitions
Paint shade RAL9006
Paint system IIa (1 epoxy base coat 30/40 microns + 1 polyurethane finish coat 20/30 microns)

Motor mechanical interface


Mounting flange - Shaft material type Steel shaft
Drive end shaft type IEC STANDARD shaft end Nuance of shaft material -
Diameter DE shaft (mm) 75m6 Second shaft extension -
Length DE shaft (mm) 140 Diameter NDE shaft (mm) -
DE bearing mounting Locked Second shaft end length (mm) -
DE bearing type DE ball bearing NDE bearing type NDE ball bearing
DE bearing 6316 NDE bearing 6218
Code Type de graissage Graisseurs

Motor electrical interface


Connection network type Radial flying cable Cable type 6+1 flying leads - 1.0m length
Connection network material Cast iron Cable gland material -
Connection network position A Main cable glan type -
Connection network orientation up Principal cable gland position Top (0)
Connection network relative position 0

Version V8.197
The information contained in this data-sheet is for guidance only and does not form part of any contract. The accuracy cannot be guaranteed as our company have an ongoing process of development and
reserve the right to change the specification of their products without notice.
Moteurs Leroy-Somer SAS. Siège social : Bd Marcellin Leroy, CS 10015, 16915 Angoulême Cedex 9, France. Capital social : 65 800 512 €, RCS Angoulême 338 567 258.
Control Techniques Limited. Registered Office: The Gro, Newtown, Powys SY16 3BE. Registered in England and Wales. Company Reg. No. 01236886.
Data sheet
N° : Date : 17 déc. 2018
Induction motor with options - 4P FLSHT 280SD 75kW IFT/IE2 400°C - 120min B30 380D/400D/415D/690Y 50Hz -

Motor options
Vibration level A (35µm ; 2.2mm/s ; 3.5m/s²) Cover Ventilated by airstream
Balancing type Half-key (H) Drip proof cover option -
Impregnation type < 95% ; -16+40°C (T) cooling type -
Winding thermal protection 1 set of 3 probes PTC (winding) Forced ventilation caracteristics -
Space heater - Encoder type -
Draining plugs position 6H Encoder caracteristics -
Nameplate material Stainless steel nameplate Screw material Stainless steel screw
Endshield thermal protection - Adaptation for vibration sensor -
Reinforced insulation system -

Motor characteristics (on mains supply)


Efficiency at Efficiency at Efficiency at
Rated Power factor Power factor Power factor
Main voltage HS rated Rated Rated speed Rated 4/4 (IEC 60 3/4 (IEC 60 2/4 (IEC 60
Frequency at 4/4 of the at 3/4 of the at 2/4 of the
(V) power (kW) torque (N.m) (min-1) current (A) 034-2-1) of 034-2-1) of 034-2-1) of
(Hz) load load load
the load (%) the load (%) the load (%)
380 50 75.000 482 1481.16 142.42 0.86 93.40

400 50 75.000 482 1484 137.0 0,84 0,8 0,71 94.00 94.20 93.90

415 50 75.000 482 1484.21 134.61 0.82 94.00

460 60 - -

Motor characteristics (on mains supply) 400 V 50 Hz


Starting torque (N.m) 1115.0 Id / In 7.61
Average starting torque (N.m) Id 1042.00
Maximum torque (N.m) 1371 Maximun current (A) 654
Unload maximum starting frequency - No-load current (A) 0.00
(d/h)
Rotor locked time (cold) (s) Acoustic pressure level (dB(A)) 70

Version V8.197
The information contained in this data-sheet is for guidance only and does not form part of any contract. The accuracy cannot be guaranteed as our company have an ongoing process of development and
reserve the right to change the specification of their products without notice.
Moteurs Leroy-Somer SAS. Siège social : Bd Marcellin Leroy, CS 10015, 16915 Angoulême Cedex 9, France. Capital social : 65 800 512 €, RCS Angoulême 338 567 258.
Control Techniques Limited. Registered Office: The Gro, Newtown, Powys SY16 3BE. Registered in England and Wales. Company Reg. No. 01236886.
Data sheet
N° : Date : 17 déc. 2018
Induction motor with options - 4P FLSHT 280SD 75kW IFT/IE2 400°C - 120min B3 380D/400D/415D/690Y 50Hz -
AA 90
AB 520
AC 479.00
AD1 45
B 368
BB 478
C 190.0
D 75m6
E 140
F 20
G 67.5
GD 12
H 280
HA 35
HJ 321.0
I 122,5
II 122,5
J 245
K 24
L 125
LB 773.0
LJ 91.5
LO 15
O M20
p 42
rs 0.8
ts 1
ts1 45
x 35

A 457

Version V8.197
The information contained in this data-sheet is for guidance only and does not form part of any contract. The accuracy cannot be guaranteed as our company have an ongoing process of development and reserve the right to change the specification of their products without notice.
Moteurs Leroy-Somer SAS. Siège social : Bd Marcellin Leroy, CS 10015, 16915 Angoulême Cedex 9, France. Capital social : 65 800 512 €, RCS Angoulême 338 567 258.
Control Techniques Limited. Registered Office: The Gro, Newtown, Powys SY16 3BE. Registered in England and Wales. Company Reg. No. 01236886.