Easy Altivar ATV310 complete parameters list ENGLISH

EAV9613605
Reference mode F007 Internal thermal sensor fault [01] negative 217 Speed Template [03] Remote display

I/O menu
Reference menu

402 External reference value F008 Internal CPU 204- AI1 CONFIGURATION MENU [00]* Standard [10] Modbus
403 Analog input virtual F009 Overbraking 204.0 AI1 type [02] DeadBand 408 Forced local assignment
F010 Overcurrent [5U]* Voltage: 0-5Vdc 300- MOTOR CONTROL MENU [00]* No: Function inactive
801 Speed reference [L1H] LI1 active High

Control menu (cont.)


59.11 Internal PID reference F011 Drive overheat [10U] Voltage: 0-10Vdc 301 Standard motor frequency
F012 Process overload [0A] Current: x-y mA [00]* 50Hz [L2H] LI2 active High
806 PID reference value [L3H] LI3 active High
F013 Motor overload [LIU] Logic inputs [01] 60Hz
Monitoring mode 204.1 AI1 current scaling parameter of 0% [L4H] LI4 active High
F014 1 Output phase loss 302 Rated motor power [LUH] LIU active High
402 External reference value F015 3 Output phases loss 0-20mA (4mA*) Drive power (-5 to +2) depending on drive rating 409 Forced local reference
403 Analog input virtual F016 Main overvoltage 204.2 AI1 current scaling parameter of 100% 303 Rated motor cos phi [00]* Not assigned
Monitoring parameter

801 Speed reference F017 Input phase loss 0-20mA (20mA*) 0.5 to 1 (depending on drive rating) [01] Terminal

Detected fault codes


802 Output frequency F018 Motor short-circuit 204.3 AI1F filter 304 Rated motor voltage [163] Remote display
803 Motor current F019 Ground short-circuit 0 s to 10 s (0 s*) 360 to 460V (380V*) [183] Integrated jog dial
804 PID error F020 IGBT short circuit 205 R1 assignment 305 Rated motor current 500- FUNCTION MENU
805 PID Feedback F021 Load short circuit [00] Not assigned 0.25 to 1.5In (depending on drive rating) 501- RAMP MENU
806 PID reference F022 Modbus interruption [01]* No error detected 306 Rated motor frequency 501.0 Acceleration
807 Main voltage F024 HMI communication [02] Drive run 10 to 400Hz (50Hz*) 0.0 to 999.9s (3.0s*)
808 Motor thermal state F025 Overspeed [04] Frequency threshold reached 307 Rated motor speed 501.1 Deceleration
809 Drive thermal state F026 PI feedback fault [05] HSP reached 0 to 24000rpM (depending on drive rating)
[06] I threshold reached 0.0 to 999.9s (3.0s*)
810 Output power F027 IGBT overheat 308 Maximum frequency 501.2 Ramp shape assignment
811 Product status F028 Autotuning fault [07] Frequency reference reached 10 to 400Hz (60Hz*) [00]* Linear

1 3
[00] Drive ready F029 Process underload [08] Motor thermal reached 309 Motor control type
[21] Underload alarm [01] S shape
[01] Drive running F030 Undervoltage [00] Performance: Vector control [02] U shape
[02] Acceleration [22] Overload alarm [03]* Standard: U/F 2 points 501.3 Ramp switching commutation
F031 Incorrect configuration [123] Loss of 4-20mA signal
[03] Deceleration F032 Invalid configuration [06] Pump: U²/F [00]* Not assigned
[04] DC injection braking in progress F033 AI1 current loss 206- LO1 CONFIGURATION MENU 310 IR compensation [L1H] LI1 active High
206.0 LO1 Assignment 25 to 200% (100%*)
Drive status

[05] Current limitaion state

Motor control menu


F034 Download invalid configuration [L2H] LI2 active High

Function / Ramp menu


[06] Freewheel stop control or freewheel state [00]* Not assigned 311 Slip compensation [L3H] LI3 active High
F035 Pre-charge resistor protection fault 0 to 150% (100%*)
[07] Auto-adatated deceleration [01] No error detected [L4H] LI4 active High
[08] Controlled stop on mains phase loss Configuration mode [02] Drive run 312 Frequency loop stability [LUH] LIU active High
[09] Auto-tuning in progress 301 Standard motor frequency [04] Frequency threshold reached 0 to 100% (20%*) [L1L] LI1 active low
[10] Fast stop state [00] 50Hz IEC [05] HSP reached 313 Frequency loop gain [L2L] LI2 active low
[11] No line power state [01] 60Hz NEMA [06] I threshold reached 0 to 100% (20%*) [L3L] LI3 active low
[12] Drive in back state 401 Reference channel 1 [07] Frequency reference reached 314 Flux Profil [L4L] LI4 active low
[13] Remote control mode [01] Terminal [08] Motor thermal reached 0 to 100% (20%*) [LUL] LIU active low
[14] Local control mode [163] Remote display [21] Underload alarm 315 Switching frequency 501.4 Acceleration 2

I/O menu (cont.)


[164] Modbus [22] Overload alarm 2 to 12kHz (4kHz*) 0.0 to 999.9s (5.0s*)
900- MAINTENANCE MENU 501.5 Deceleration 2
901 State of logic inputs LI1 to LI4 [183] Integrated display with Jog dial [123] AI1 alarm 4-20mA 317 Motor noise reduction
501.0 Acceleration [126] Auxiliary pump active [00]* No 0.0 to 999.9s (5.0s*)
902 State of the logic output LO1 and relay R1 501.6 Decel Ramp Adaptation assignment
903 Display of high speed value 0.0 s to 999.9s (3.0s*) 206.1 LO1 status (output active level) [01] Yes
501.1 Deceleration [00]* Positive : hight activation level [00] Function deactivated
904 Drive Power rating 318 Auto-tuning [01]* Function activated
037 0.0 s to 999.9s (3.0s*) [01] Negative : low activation level [00]* No: When factory paramameters of stan- [02] Motor brake
075 512.0 Low speed 207 Application Overload time delay dard motors 502- STOP CONFIGURATION MENU
U15 0.0Hz to High speed (0Hz*) 0 to 100 s (0 s*) [01] Yes: Launches auto-tuning 502.0 Type of stop
U22 512.2 High speed 208 Application Overload threshold [02] Done: If auto-tuning has already been [00]* Ramp stop
Low speed to max. frequency (mot. frequency*) 70 to 150% of nominal motor current (90%*)
Short menu

U30 performed [01] Fast stop


U40 302 Rated Motor Power 209 Overload fault duration 319 Motor parameter choice [02] Free wheel stop
U55 NCV -5 to NCV +2 (according to drive rating*) 0 to 6 min (0 min*) [00]* Nominal motor power [03] DC injection stop
U75 305 Rated motor current 210 Application underload time delay [01] Nominal motor cos phi 502.1 Freewheel stop assignment

Function / Stop configuration menu


D11 (0.25-1.5In) (In*) 0 to 100 s (0 s*) 320 Vector control 2 points [00]* Not assigned
905 Drive voltage rating 204.0 AI1 type 211 Application Underload threshold [00]* No [L1L] LI1 active Low to stop

2 4
N4 [5U]* 0-5V 20 to 100% of nominal motor current (60%*) [01] Yes [L2L] LI2 active Low to stop
906 Specific Product Number [10U] 0-10V 212 Underload fault duration 321 Max voltage of constant power [L3L] LI3 active Low to stop
907 Card 1 Software Version [0A] x-y mA 0 to 6min (0min*) [L4L] LI4 active Low to stop
Maintenance menu

360 to 460V (380V*)


908 Card 2 Software Version [LIU] Logic inputs 213 Motor frequency threshold 322 Max frequency of constant power [LUL] LIU active Low to stop
909 Run elapsed time display 101 Store customer parameter set 0 to 400Hz (50Hz* or 60Hz) 50 to 400Hz (50Hz*) 502.2 Fast stop assignment
910 Power On time display [00]* Disabled 214 Motor current threshold [00]* Not assigned
400- CONTROL MENU [L1L] LI1 active Low to stop
911 Fan time display [01] Stores current configuration 0 to 1.5In (In*) 401 Reference channel 1
912 Process Elapsed time 102 Factory / recall customer parameter set [L2L] LI2 active Low to stop
215 Motor thermal state threshold [01] Terminal [L3L] LI3 active Low to stop
913 Modbus communication status [00]* Disabled [163] Remote display
[02] Customer configuration 0 to 118% (100%*) [164] Modbus [L4L] LI4 active Low to stop
914 Last fault 1
915 State of drive at fault 1 [64] Factory set configuration 216.0 AOI assignment [183] Integrated display with Jog dial [LUL] LIU active Low to stop
916 Last fault 2 COMPLETE MENU [00]* Not assigned 402 External reference value 502.3 Ramp divider
100 Macro-configuration [129] Motor current -400 to 400Hz 1 to 10 (4*)
917 State of drive at fault 2 502.4 DC injection assignment

Control menu
403 Analog input virtual
Macro

918 Last fault 3 [00] Start/stop [130] Output frequency


[04] PID regulation 0 to 100% 502.5 DC injection level
919 State of drive at fault 3 [131] Ramp output 502.6 IDC injection time for DCLI
920 Last fault 4 [09] Speed 404 Reverse inhibition
[135] PID reference [00]* No 502.7 DC injection level 2
921 State of drive at fault 4 200- I/O MENU [136] PID feedback [01] Yes 502.8 Injection standstill braking time
999 HMI Password 201 Type of control [137] PID error 405 Stop key priority 503 Reverse direction
F000 Fault menu [00]* 2-wire control [139] Output power [00] No: Stop inactive
[01] 3-wire control [00]* Not assigned
F001 Precharge

reverse direction
[01]* Yes: Stop active
I/O menu

202 2-wire type control [140] Motor thermal state [L1H] LI1 active High
F002 Unknown drive rating [141] Drive thermal state 406 Channel configuration [L2H] LI2 active High

Function
F003 Unknown or incompatible power board [00] level [01]* Not separate mode
[01]* transition 216.1 AOI type [L3H] LI3 active High
F004 Internal serial link [02] Forward priority [02] Separate mode [L4H] LI4 active High
[10U] Voltage: 0-10 Vdc 407 Command channel 1
F005 Invalid industrialization zone 203 Logic inputs type [0A]* Current: 0-20 mA [LUH] LIU active High
F006 Current measurement circuit [00]* positive [01]* Terminals 504- AUTO DC INJECTION MENU
[4A] Current: 4-20 mA [02] Local
The (*) indicates a parameter factory setting.

www.schneider-electric.com 1/2
Easy Altivar ATV310 complete parameters list
504.0 Automatic DC injection 59- PID MENU 59.24 Maximum frequency detection Hysteresis 512.4 4 High speed assignment 610 Detected fault inhibition assignment
DC injection function

Speed limitation function (cont.)

Degr. Modbus Det. fault inhibit.


[00] Function inactive, no DC injected current. 59.00 PID feedback assignment 0 to 50Hz (0Hz*) [00]* Not assigned [00]* Function inactive
[01]* Time limited DC injection [00]* Not assigned 59.25 PID feedback supervision [L1H] LI1 active High [L1H] LI1 active High
[02] Continuous DC injection [01] Terminal [00]* Not assigned [L2H] LI2 active High [L2H] LI2 active High
504.1 Automatic DC injection current 59.01 PID proportional gain [01] Free wheel [L3H] LI3 active High [L3H] LI3 active High
0 to 120% of nominal motor current (70%*) 0.01 to 100 (1*) [04] Fallback speed [L4H] LI4 active High [L4H] LI4 active High
504.2 Automatic DC injection time 59.02 PID integral gain 59.26 Fallback speed [LUH] LIU active High [LUH] LIU active High
512.5 High speed 2 611 Modbus detected fault management

line interrup.
0.1 to 30s (0.5s*) 0.01 to 100 (1*) 0 to High speed (0Hz*)
505 Jog assignment 59.03 PID derivative gain 510- PUMP SUB-MENU Low speed to Max frequency (50 or 60Hz*) [00]* Detected fault ignored
[00]* Not assigned 0.00 to 100.0 (0*) 207 Overload time delay 512.6 High speed 3 [01] Freewheel stop
[L1H] LI1 active High 59.04 PID feedback scale factor Low speed to Max frequency (50 or 60Hz*) 612 Degraded line supply operation
Jog function

0 to 100 s (0 s*)
[L2H] LI2 active High 0.1 to 100.0 (1.0*) 208 Overload threshold 512.7 High speed 4 [00]* No
[L3H] LI3 active High 59.05 Activation internal PID reference 70 to 150% of nominal motor current (90%*) Low speed to Max frequency (50 or 60Hz*) [01] Yes
[L4H] LI4 active High [00]* No 209 Overload fault duration 513 Cooling fan control 613 Reset power run

Fan
[LUH] LIU active High [01] Yes 0 to 6 min (0 min*) [00] Fan runs when drive runs [00]* No

Reset power run


506- Speed up and down 59.06 2 preset PID assignment 210 Underload time delay [01]* Thermal control [03] Reset drive running time
506.0 Up speed command [00]* Not assigned 0 to 100 s (0 s*) 600- FAULT DETECTION MANAGEMENT MENU [04] Reset power-on time

Detected fault reset


[00]* Not assigned [L1H] LI1 active High 211 Underload threshold 601 Detected fault reset assignment [07] Reset fan operation time

PID / Pump mangement function


[L1H] LI1 active High [L2H] LI2 active High 20 to 120% of nominal motor current (60%*) [00]* Not assigned 614 Reset all previous detected faults via Run key
[L2H] LI2 active High [L3H] LI3 active High 212 Underload fault duration [L1H] LI1 active High of HMI
[L3H] LI3 active High [L4H] LI4 active High [00]* Deactivated

7
0 to 6min (0min*) [L2H] LI2 active High

5
[L4H] LI4 active High [LUH] LIU active High 510.0 Selecting operating mode [L3H] LI3 active High [01] Active
[LUH] LIU active High 59.07 4 preset PID assignment [00]* Single frequency conversion mode [L4H] LI4 active High 700- COMMUNICATION MENU
506.1 Down speed command [00]* Not assigned [01] Single frequency conversion combined [LUH] LIU active High 701 Modbus address
[00]* Not assigned [L1H] LI1 active High with auxiliary pump mode 602- AUTOMATIC RESTART MENU Off to 247 (off*)
[L1H] LI1 active High [L2H] LI2 active High 510.1 Starting frequency of the auxiliary pump 602.0 Automatic restart 702 Modbus baud rate
Motor potentiometer function

[L2H] LI2 active High [L3H] LI3 active High 0 to 60Hz (50Hz*) [00]* No [24] 4.8 kbps

after a etected fault


[L3H] LI3 active High [L4H] LI4 active High

Automatic restart
510.2 Time delay before starting auxiliary pump [01] Yes [28] 9.6 kbps
[L4H] LI4 active High [LUH] LIU active High 0 to 999.9s (2s*) 602.1 Max. automatic restart [32]* 19.2 kbps
[LUH] LIU active High 59.08 2 preset PID reference 510.3 Auxiliary pump ramp reaching [00]* 5 min [36] 38.4 kbps
506.2 Store 0 to 100% (25%*) 0 to 999.9s (2s*) [01] 10 min 703 Modbus format
[00]* No 59.09 3 preset PID reference 510.4 Auxiliary pump stop frequency [02] 30 min [02] 8o1
[01] RAM 0 to 100% (50%*) 0 to 60Hz (0Hz*) [03] 1 hour [03]* 8E1
[02] ROM 59.10 4 preset PID reference 510.5 Auxiliary pump stop time delay [04] 2 hours [04] 8n1
506.3 Clear the function 0 to 100% (75%*) 0 to 999.9s (2s*) [05] 3 hours [05] 8n2
PID Control function

[00]* Not assigned 59.11 Internal PID reference 510.6 Auxiliary pump stop ramp [06] Infinite 704 Modbus time out
[L1H] LI1 active High 0 to 100% (0%*) 0 to 999.9s (2s*) 603 Catch on the fly 0.1 to 30s (10s*)

Catch on
the fly
[L2H] LI2 active High 59.12 PID reference ramp 510.7 Zero flow detection period [00]* Function inactive 705- INPUT SCANNER MENU
[L3H] LI3 active High 0 to 100% (0%*) 0 to 20min (0min*) [01] Function active 705.0 Com scanner read adress parameter 1
[L4H] LI4 active High 59.13 PID min value reference 510.8 Zero flow detection activation threshold 604- MOTOR THERMAL PROTECTION MENU 0C81*
[LUH] LIU active High 0 to 100% (0%*) 0 to 400Hz (0Hz*) 604.0 Motor thermal current 705.1 Com scanner read adress parameter 2
[159] Acceleration and deceleration with com-

Motor thermal protection


59.14 PID max value reference 510.9 Zero flow detection offset 0.2-1.5In (According to drive rating*) 219C*
mand active high 0 to 100% (100%*) 0 to 400Hz (0Hz*) 604.1 Motor protection type 705.2 Com scanner read adress parameter 3
506.4 Reactivity of +/- speed around ref. 59.15 PID predictive speed 511- CURRENT LIMITATION MENU [01]* Self-ventilated 0000

PID / Pump mangement function


0 to 100% (0%*) 0.1 to 400Hz (0.0*) 511.0 2nd current limitation commutation [02] Motor-ventilated 705.3 Com scanner read adress parameter 4
507- PRESET SPEED MENU 501.4 Acceleration 2 604.2 Overload fault management 0000

Communication menu
[00]* Not activated [00] Detected fault ignored
507.0 2 Preset speeds 0.0 to 999.9s (5s*) [L1H] LI1 active High 706- OUTPUT SCANNER MENU
[00]* Not assigned 59.16 PID correction reverse [01]* Free wheel stop
[L2H] LI2 active High 604.3 Motor thermal state memo 706.0 Com scanner write adress parameter 1
[L1H] LI1 active High [00]* No, no negative speed [L3H] LI3 active High 2135*
[L2H] LI2 active High [01] Yes, no negative speed [00]* thermal state not stored at power off
[L4H] LI4 active High [01] thermal state is stored at power off 706.1 Com scanner write adress parameter 2

6 8
[L3H] LI3 active High [02] No, allow negative speed [LUH] LIU active High 219A*
[L4H] LI4 active High [03] Yes, allow negative speed 605 Output Phase loss
[L1L] LI1 active Low [00] Deactivated 706.2 Com scanner write adress parameter 3
[LUH] LIU active High 59.17 PID auto/manual assignment [L2L] LI2 active Low

Phase loss
[01]* Tripping then freewheel stop 0000
507.1 4 Preset speeds [00]* Not assigned [L3L] LI3 active Low 706.3 Com scanner write adress parameter 4
same as 2 Preset speeds [L1H] LI1 active High 606 Input Phase loss
[L4L] LI4 active Low [00] Detected fault ignored 0000
507.2 8 Preset speeds [L2H] LI2 active High [LUL] LIU active Low 707- INPUT SCANNER ACCESS MENU
Maintenance menu

same as 2 Preset speeds [L3H] LI3 active High [01]* Detected fault with freewheel stop
511.1 Current limitation 607- UNDERVOLTAGE MENU 707.0 Com scanner read adress value 1
507.3 Preset speed 2 [L4H] LI4 active High 0.25 to 1.5In (1.5In*)
[LUH] LIU active High 607.0 Undervoltage detected fault management 0C81*
0 to 400Hz (10Hz*) 511.2 Current limitation 2 707.1 Com scanner read adress value 2
507.4 Preset speed 3 59.18 PID manual reference [00]* Detected fault and R1 relay open
0.25 to 1.5In (1.5In*)

Undervoltage
[00]* No [01] Detected fault and R1 relay closed 219C*
0 to 400Hz (15Hz*) 512- SPEED LIMIT MENU 607.1 Undervoltage prevention 707.2 Com scanner read adress value 3
507.5 Preset speed 4 [01] Yes [00]* No action (freewheel)
[183] Integrated jog dial 512.0 Low speed 0000
0 to 400Hz (20Hz*) 0Hz to high speed (0Hz*) [02] Stop following an adjustable ramp 707.3 Com scanner read adress value 4
Speed limitation function

507.6 Preset speed 5 512.1 Low speed operating time 607.2 Undervoltage ramp deceleration time
0.1 to 999.9s (0s*) 512.1 Low speed operating time 0000
0 to 400Hz (25Hz*) 0.1 to 999.9s (0s*) 0.0 to 10.0s (1.0s*)
507.7 Preset speed 6 59.19 PID: wake up level 708- OUTPUT SCANNER ACCESS MENU
512.2 High speed 607.3 Precharge resistor protection level 708.0 Com scanner write adress value 1
0 to 400Hz (30Hz*) 0 to 100% (0%*) 430 to 560 VDC (0 V* with protection removed)
Low speed to maximum frequency (50 or 60Hz CMD value*
507.8 Preset speed 7 according to standard motor frequency*) 608 IGBT test
0 to 400Hz (35Hz*) 59.20 PID: Wake up threshold 708.1 Com scanner write adress value 2

IGBT
512.3 2 High speed assignment [00]* No test
507.9 Preset speed 8 0 to 100% (0%*) [01] Starting test LFRD value*
59.21 Sleep offset threshold [00]* Not assigned 708.2 Com scanner write adress value 3
0 to 400Hz (40Hz*) [L1H] LI1 active High 609 4-20mA loss Behaviour
508 Skip frequency 0 to High speed (0Hz*) [00]* Detected fault ignored 8000
59.22 PID feedback supervision threshold [L2H] LI2 active High 4-20 mA loss 708.3 Com scanner write adress value 4
0 to 400Hz (0Hz*) [01] Freewheel stop
frequency

0 to 100% (0%*) [L3H] LI3 active High 8000


Jump

59.23 PID supervision function time delay [L4H] LI4 active High
0 to 300s (0s*) [LUH] LIU active High

The (*) indicates a parameter factory setting.