ASU REMOTE MONITORING Air+Mak
USER MANUAL Industries, Inc.
TABLE OF CONTENTS
SUBJECT PAGE
6. SYSTEM PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Page 2
ASU REMOTE MONITORING Air+Mak
USER MANUAL Industries, Inc.
Mak ASU Remote Monitoring system is Modular Hardware integrated with ASU control panel to
monitor ASU operation / control & whereabouts from remote place through Web Enabled
application. It is an integration of GPS and GSM/GPRS based Communication module.
2. Features
3. Benefits
Page 3
ASU REMOTE MONITORING Air+Mak
USER MANUAL Industries, Inc.
Command ID - 07
Data Range - 01 to 99 (Multiple of 15 Minutes), 00 - Turn off tracking message
Examples:
For programming 15 minutes interval time
Send SMS with text as “<>07#01*” to SIM Number.
For programming 60 minutes /1 hour interval time
Send SMS with text as “<>07#04*” to SIM Number.
Command ID - 10
Data Range - ON or OFF (Not case sensitive)
Page 4
ASU REMOTE MONITORING Air+Mak
USER MANUAL Industries, Inc.
Examples:
Start Enable (ON)
Send SMS with text as “<>10#on*” (or) “<>10#ON*” to SIM Number.
Start Disable (OFF)
Send SMS with text as “<>10#off*” (or) “<>10#OFF*” to SIM Number.
Command ID - 09
Data Range - ON or OFF (Not case sensitive)
Examples:
ON:
Send SMS with text as “<>09#on*” (or) “<>09#ON*” to SIM Number.
OFF:
Send SMS with text as “<>09#off*” (or) “<>09#OFF*” to SIM Number.
Command ID - 13
Data Range - TRACK (Not case sensitive)
Send SMS with text as “<>13#track*” (or) “<>13#TRACK*” to SIM Number.
Page 5
ASU REMOTE MONITORING Air+Mak
USER MANUAL Industries, Inc.
1. FAULT INFORMATION’S
Following fault messages are forwarded to the designated email ids when the particular
engine fault is occurred.
a. ENGINE FAULTS
1. LOW LUBE OIL PRESSURE FAULT :
“ASU SERIAL NUMBER: 083
DATE :15/10/2008
TIME: 8:30:10AM
ASU SHUTDOWN BY ENGINE LOW LUBE OIL PRESSURE FAULT
OIL PRESSURE: 0.9 BAR”
Page 6
ASU REMOTE MONITORING Air+Mak
USER MANUAL Industries, Inc.
Page 7
ASU REMOTE MONITORING Air+Mak
USER MANUAL Industries, Inc.
b. COMPRESSOR FAULTS:
Page 8
ASU REMOTE MONITORING Air+Mak
USER MANUAL Industries, Inc.
Page 9
ASU REMOTE MONITORING Air+Mak
USER MANUAL Industries, Inc.
c. MAINTENANCE INFORMATION:
Following maintenance messages are sent to the designated email ids when the maintenance
period is elapsed.
If any set maintenance hours reaches less than 50hours, the following messages
Will be sent on every 24 hours.
If any set maintenance days reaches less than 10days, the following messages
Will be sent once 24 hours. Day will automatically decremented after 24 hours
Page 10
ASU REMOTE MONITORING Air+Mak
USER MANUAL Industries, Inc.
“ASU SERIAL NUMBER: 083
DATE: 01/01/2008
FUEL FILTER REPLACEMENT DUE IN 010 DAYS”
Page 11
ASU REMOTE MONITORING Air+Mak
USER MANUAL Industries, Inc.
“ASU SERIAL NUMBER: 083
CURRENT RUN HOURS: 0400 HOURS
ENGINE OIL & FILTER REPLACEMENT PAST DUE 050 HOURS”
Page 12
ASU REMOTE MONITORING Air+Mak
USER MANUAL Industries, Inc.
Note: (1) When ASU-OFF and Control panel is in ON, the following message will
be in the status line.
STATUS: ASU-OFF CONTROL PANEL: ON
(2) When the ASU start DISABLED the following message will be in the
ASU start line.
Page 13
ASU REMOTE MONITORING Air+Mak
USER MANUAL Industries, Inc.
6. SYSTEM PROGRAMMING
To enter this mode, Press SEL Key and FAULTCLEAR Key in RUN mode. The Display
screen looks like as below,
Remote Monitor
Mode
Enter PWD:0000
Turn OFF
Power ON & Try
Invalid Password
Entered PW: 0000
If password is correct, system will edit unit serial number as shown below.
Remote Monitor
Mode
After entering Unit serial Number, system will edit Remote monitor ON/OFF selection as shown
below.
Page 14
ASU REMOTE MONITORING Air+Mak
USER MANUAL Industries, Inc.
ON:
If the remote monitor is on, the system will give the remote diagnosis data and event
capturing through Rs-232 to Remote Monitor (MWT) System.
No Fault Condition: In this condition, the remote monitor (MWT) system gets the diagnosis
data for every 5 sec through Rs-232 in Normal basis.
Fault condition: If any fault (Engine or Compressor) is occurred, the remote monitor system
gets the first fault of the unit through Rs-232 in event basis.
OFF:
If the remote monitor is off, get the RS-232 data from the CPU card and provides in the high
speed USB bus for data logging of on line and off line data.
See the “on line” and “off line ” data in PC (personal Computer).
After selecting remote monitor On/Off, Remote Monitor programming will be over, the
screen as shown below,
Remote Settings
Successful
Press FAULTCLEAR
Key to Exit
Note: i). Using DIGITSEL, PAGEUP/INC key, required value could be programmed.
Once done, Press SET/ MENU key to store entered data.
Page 15
ASU REMOTE MONITORING Air+Mak
USER MANUAL Industries, Inc.
When user Mode is enabled the following screen appears during startup
ASU start
Disabled
User id : 01
Press ^ to
Select User or
Press SET/MENU
Press PAGEUP key to change user id and SET/MENU to enter password page press.
USER id : 01
Now press PAGEUP key to increment the value and press SEL key to select the Digit. After entering
the correct password Press SET/MENU.
Password
Accepted
Press FAULTCLEAR
Key to Exit