Professional Documents
Culture Documents
(NTU) Flowmeter Catalog
(NTU) Flowmeter Catalog
Summary
There are two types of LZS series flow meters, long tube type and short tube type. Their difference is that there is no guide
rod (leader) in the middle of long tube type flow meter, therefore its precision is lower than short type with the guide rod.
The float of this series flow meter all adopt the plastic shell, so it has excellent performance of acid resistant, alkali
resistant and corrosion resistant.
Technical Parameters
LZS-15 LZS-20 LZS-25 LZS-32 LZS-40 LZS-50 LZS-65 LZS-80 LZS-100 LZS-125 LZS-150
Model
(L/h) (L/h) (L/h) (m3/h) (m3/h) (m3/h) (m3/h) (m3/h) (m3/h) (m3/h) (m3/h)
6-60
10-100
60-600 1-10
16-160 0.4-4 0.4-4 5-25 8-50 18-120 18-120
40-400 100-1000 0.4-4 1.6-16
Measure 25-250 0.6-6 0.6-6 8-40 12-60 15-150 15-150
60-600 160-1600 0.6-6 5-25
Range 40-400 1-10 1-10 12-60 14-90 22-180 22-180
100-1000 250-2500 1-10 8-40
60-600 1.2-12 1.6-16 12-80 18-120 25-200 25-200
300-3000 12-60
80-800
100-1000
Short Tube
Type Long Tube Short Tube Short Tube
Flange Connection
Accuracy ±4%
Temperature 0-60oC
Pressure ≤0.6 MPa
Type of Connection
Construction
Note Glue & Screw Type Flange Type
1. The materials of part of the flow
meter: tapper tube is AS, leader 1. Joint pipe 1. Flange
is SS304, other are all ABS 2. Screw cap 2. O-ring
2. The flow meter under DN 65 3. O-ring 3. Taper tube
4. Upper stop plate 4. Scale
could be made into flange
5. Scale 5. Leader
connection type of screw thread
6. Taper tube 6. Float
connection type 7. Float
3. The materials of flow, joint pipe 8. Lower stop plate
and leader could be customized
LZM-G Series Tube Type Flowmeter
Technical Parameters
Measure Range Size (mm)
Screw Accu
Model Liquid Gas
Thread racy A B C D E F G
(ml/min) (L/min)
0.1-1
6-60 0.2-2
0.25-2.5 Direct
LZM-4T 8-80 0.6-6 94 27 21 14 Ф14 70 11
1-5 Ф6
10-100 1-10
1-12
0.5-5L/H
0.1-1 0.1-1.5
1.5-15L/H
0.3-3 0.4-4
9-90L/H
1-5 1-12
0-3LPM
2-10 2-20
6-60L/H (F) G ¼”
LZM-6T 3-15 3-30 ±4% 102 29 25 20 M18x1.5 77 12.5
10-100 BSP
4-40 5-50
16-160
10-60 10-70
25-250
30- 10-
100-500
300ml/min 100LPM
100-1000
2.5-25LPH 110
0.1-1m3/h
5-45LPH (F) G ¼”
LZM-8T 0.16-1.6m3/h 25 25 20 M18x1.5 80 12
6-60LPH BSP
0.2-2m3h
9-90LPH
Technical Parameters
Measure Range Size (mm)
Gas
Model Liquid Liquid Accuracy
(Nm3/h) A B C D E F G
(GPM) (LPM)
0.1-1 0.5-4
0.2-2 0.8-8 1-10
0.3-3 1-11 1.6-16 (M)
LZM-15L 216 32 206 37 23 165
0.3-5 2-18 2.5-25 ½” BSP
1-7 2-28 4-40
1.5-9 400-2000LPH
2.5-25
2-10 8-40
6-60 ±4% (M)
LZM-20L 2-16 8-60 233 39 220 44 28 165
10-100 ¾” BSP
2-20 8-80
16-160
1.5-15 6-60
3-13 10-50
20-200 (M)
LZM-25L 4-24 10-100 253 44 240 50 35 175
25-250 1” BSP
5-35 10-130
5-45 20-170
Technical Parameters
Measure Range Size (mm)
Gas Screw Accu
Model Liquid
Liquid (LPM) (Nm3/h) Thread racy A B C D E F G
(GPM)
0.2-2 0.1-1
0.05-0.5 0.5-4 0.2-2
(M)
0.1-1 1-7 0.5-3
½”BSPT
0.2-1 1-11 0.6-6
LZM-15 176 32 168 35 26.5 76 127
0.2-2 2-18 1.2-12
(F)
0.3-3 10-100LPH 1.6-16
¼”BSPT
0.5-5 16-160LPH 2.5-25
250-250LPH 1-10
1-10 5-40
2-15 10-50
6-60 ±4%
2-20 10-70 (M)
LZM-25 16-160 234 45 226 46 33 100 160
3-30 10-120 1”BSPT
25-250
5-35 20-140
5-40 10-150
5-45 10-170
10-50 50-190
10-60 20-220 (M)
LZM-50 296 70 281 82.5 50 120 189
20-80 90-300 2”BSPT
25-100 100-350
30-150 100-500
Technical Parameters
Measure Range Connection Size (mm)
Model
L/min Type A B C D E
LZQ-1 0-5 70 52 15 20
LZQ-2 0-3 80 58.5 15.5 22
0-5
LZQ-3 90 65.5 20 22
0-10
0-5
LZQ-4 2-10 115 90 20 22
1.5-15
LZQ-5 2.5-25 120 92 21 23
Hose M8x1
0-5
LZQ-6 2-10 100 76 25 24
2-20
0.3-3
1-5
2-10
LZQ-7 120 94.5 22 20
1-15
2-20
3-30
Summary
The flowmeter is suitable for small flow rate of gas and liquid measure, main body chooses PC (polycarbonate) plastic
injection molding, the style is divided into two with regulator and the regulator, the product is durable, strong process
stability, small size, can remove for cleaning installation at any time. This product flow scale printed on the front panel,
paste in the flow tube, read float the indicated flow accurately.
Warning: the flow meter is used for the appropriate media, such as alcohol medium shall not apply.
0.5–5
1–10
1–1.5
5–25
Z–7000 1–2 ±5% 0 - +60oC ≤0.6 MPa 1/8 PT
7–70
1–3
5–50
10–100
Flow Alarm Switch
Summary
Applies to a panel meter, plastic pipe flowmeter, glass rotor flowmeter upper limit alarm or lower limit alarm. Bi-stable
switch can meet the demands for all kinds of the CARDS on the measuring tube dovetail guide way, flow value can be set
arbitrary installation is simple, reliable, and easy to add Ze950 on existing equipment and Ze951 flow limit switch can be
in the middle of the maximum, minimum or any signal flow value. This product is installed on the Z-5025-Z-5065 series
flowmeter measurement tube dovetail guide way, when float reach or exceed the limit switch position, namely the signal.
At this point, the internal contact will be turned on or off. The adoption of new magnetic induction technology, now no
longer as in the past will float for monostable and occasion.
Technical Parameters
Insulation Impedance : >109Ω Working Voltage : max. DC24/AC24
Working Temperature : 0oC + 55OC Working Current : max.0.3A
Protection Level : IP65 The Constant Current Switch : max.DC0.1A
Lag (and Off Location) : 4mm Interrupt Power : max.1VA
Outline Dimension : 45x20x45 Forward Resistance : <200MΩ
LZM Series Flowmeter with Alarm Limit LZS Series Flowmeter with Alarm Limit LZB Series Flowmeter with Alarm
Switches Switches Limit Switches
Technical Parameters
Range
Model Working Pressure Accuracy
Water Air (0.1013 MPa)
0.4-4 ml/min 6-60 ml/min
0.06-6 ml/min 10-100 ml/min
1-10 ml/min 16-160 ml/min
1.6-16 ml/min 25-250 ml/min
3
2.5-25 ml/min 40-400 ml/min
4-40 ml/min 60-600 ml/min
6-60 ml/min 100-1000 ml/min
10-100 ml/min 160-1600 ml/min
1-10 l/h 16-160 l/h ≤ 1.0 MPa ± 2.5%
4 1.6-16 l/h 25-250 l/h
2.5-25 l/h 40-400 l/h
2.5-25 l/h 40-400 l/h
6 4-40 l/h 60-600 l/h
6-60 l/h 100-1000 l/h
6-60 l/h 100-1000 l/h
10 10-100 l/h 160-1600 l/h
16-160 l/h 250-2500 l/h
Dimension
Size (mm)
Model
A B C D E F
LZB-3 116 136 Ф8 26x25
LZB-4 178 204 234 Ф9 39.5x34 2-M6
LZB-6 178 204 234 Ф9 39.5x34 2-M6
LZB-10 178 208 238 Ф 12 39.5x34 2-M6
LZB and LZB-F Glass Tube Rotameter
Technical Parameters
Range
Model Workig Pressure Accuracy
GPM Gas (0.1013 MPa)
16-160 l/h 0.25 -2.5 m3/h
15 25-250 l/h 0.40-4 m3/h ± 2.5%
40-400 l/h 0.60-6 m3/h
40-400 l/h 1-10 m3/h
25 60-600 l/h 1.6-16 m3/h
≤ 0.6 MPa
100-1000 l/h 2.5-25 m3/h
160-1600 l/h 4-40 m3/h
40
250-2500 l/h 6-60 m3/h
400-4000 l/h 10-100 m3/h ± 1.5%
50
600-6000 l/h 16-160 m3/h
1-10 m3/h 50-250 m3/h
80
1.6-16 m3/h 80-400 m3/h
≤ 0.4 MPa
5-25 m3/h 12-600 m3/h
100
8-40 m3/h 200-1000 m3/h
Dimension
Size (mm)
Model
A B C D E
LZB-15 Ф 95 Ф 65 470 Ф 15 4- Ф 14
LZB-25 Ф 115 Ф 85 470 Ф 25 4- Ф 14
LZB-40 Ф 145 Ф 110 570 Ф 40 4- Ф 14
LZB-50 Ф 160 Ф 125 570 Ф 50 4- Ф 18
LZB-80 Ф 185 Ф 150 660 Ф 80 4- Ф 18
LZB-100 Ф 205 Ф 170 660 Ф 100 4- Ф 18
The Basic Parameters are Specified as below:
1. Operating temperature: -20 – 120oC
2. (F-Corrosion Resistant Type) Corrosion resistant type flow meter is according to the requirement of the medium
and adopts the corresponding corrosion resistant material satisfy the technology requirement of the clients.
3. The whole stainless steel flow meters could be customized into DN Ф20, Ф32, and Ф65.
1. Outlet 1. Outlet
2. Base (up) 2. Base (up)
3. Organic cover shell 3. Organic cover shell
4. Taper pipe 4. Taper pipe
5. Baseplate 5. Baseplate
6. Float 6. Float
7. Inlet 7. Inlet
8. Base (down) 8. Base (down)
9. Cup valve 9. Cup valve
Technical Parameters
Measure Range Water (20oC) 4-6000 l/h; Air (20oC) 101325 Pa ; 12-30 m3/h
Range of Degrees 10 : 1
The Accuracy Level 1.6
Taper Pipe Length 300 mm
Scale mm scale and flow scale
Maximum Pressure DN15-25: 1.0 MPa; DN40: 0.9 MPa
By Current Body Condition
The Highest Temperature 120oC
Specifications
Range
Nominal Working
Model Water Air Accuracy Temperature
Diameter Pressure
(20oC, l/h) (20oC, 101325 Pa, m3/h)
4-40 6.3-63
0.12-1.2
10-100 12-120 0.2-2
0.3-3
VA 10-15 16-160 20-200 0.4-4
0.5-5
15 SA 10-15 25-250 30-300 0.6-6
0.8-8
FA 10-15 36-360 40-400 0.9-9
1.2-12
46-460 63-630 2-20
≤ 1.0 MPa
65-650 75-750
4-400 50-500
1.6-16 2-20
VA 10-25 63-630 80-800
2.5-25 3-30 -20oC - +60 oC
25 SA 10-25 100-1000 120-2000 ± 1.5%
4-40 5-50 Or
FA 10-25 160-1600 200-2000
6-60 -20oC - +120 oC
250-2500 300-3000
VA 10-40 160-1600 200-2000 5-50
6-60
40 SA 10-40 250-2500 300-3000 8-80 ≤ 0.9 MPa
9-90
FA 10-40 400-4000 500-5000 12-120
250-2500
300-3000
VA 10-50 400-4000 10-100
500-5000 12-120
50 SA 10-50 630-6300 16-160 ≤ 0.7 MPa
800-8000 20-200
FA 10-50 1000-10000 30-300
1500-15000
4000-16000
Installation Size Table
The VA10 SA10 FA10
Nominal Window
Diameter Size Pipe
L1 C L2 C D L3 C D E
axb Thread
Summary
VA/SA/FA 10 type glass rotameter is adopting international advanced technology and equipment manufacturing products,
with pipe thread connection (VA10 type), hose (SA10 type), flange connection type (FA10 type) three ways, the maximum
working pressure and the maximum operating temperature of the same size were higher than the original LZB/LZJ series
glass rotor flowmeter. The product has high accuracy and good for the interchange function, wide flow range and
connection mode, the advantages of easy installation and maintenance, FA10 flange rotating type flow meter, in
accordance with the piping flange hole.
The product can also according to different fluid temperature, pressure, density, viscosity, and other physical quantities,
to provide users with different fluid flow scale, the different status, solve the problem of fixed value, greatly facilitate the
use of the user, alternative to turn the instrument on the introduction of complete sets of equipment, widely used in
chemical industry, light industry, pharmacy, food, paper making, environmental protection and measurement test,
scientific research departments, measurement or single phase of pulsating flow of fluid (liquid or gas).
LZB-VA/SA/FA20 Glass Tube Rotameter
Rotameter
Technical Parameters
Measure Range Water (20oC) 4-36000 l/h; Air (20oC) 101325 Pa ; 12-300 m3/h
Range of Degrees 10 : 1
The Accuracy Level 1.6
Taper Pipe Length 300 mm
Scale mm scale and flow scale
Maximum Pressure DN15-25: 1.0 MPa; DN40: 0.9 MPa
By Current Body Condition
The Highest Temperature 120oC
Specifications
Model Measure Range
Nominal Air Loss of Pressure
The Corrosion Water o
Diameter Ordinary (20 C, 101325 Pa, (Pa)
Type (20oC, l/h)
m3/h)
4-40 100
0.12-1.2
6-60 1100
0.2-2
10-100 1200
0.3-3
15 VA/SA/FA20-15 VA/SA/FA20-15F 16-160 1700
0.5-5
25-250 2000
0.8-8
40-400 2500
1.2-12
63-630 3000
63-630 2-20 2800
100-1000 3-30 4000
25 VA/SA/FA20-25 VA/SA/FA20-25F
160-1600 5-50 5000
250-2500 8-80 6000
160-1600 5-50 3400
40 VA/SA/FA20-40 VA/SA/FA20-40F 250-2500 8-80 4000
400-4000 12-120 5000
400-4000 12-120 4800
50 VA/SA/FA20-50 VA/SA/FA20-50F 630-6300 20-200 6500
1000-10000 30-300 8500
Installation Size Table
Nominal VA20 SA20 FA20
Diameter L1 A Pipe Thread L2 A B L3 C D E
*G ½
15 Ф58 *G 3/8 400 Ф58 Ф17 Ф65 Ф95
*NPT3/8
4-Ф14
G1
25 Ф74 *G ¾ Ф74 Ф30 Ф85 Ф115
375 425
*NPT1
*G1 ½ 450
40 Ф92 Ф92 Ф44 Ф110 Ф145
*NPT1 1/2
4-Ф18
G2
50 Ф122 Ф122 Ф44 Ф125 Ф160
*NPT2
Summary
VA/SA/FA 20 type glass rotameter is adopting international advanced technology and equipment manufacturing products,
with pipe thread connection (VA20 type), hose (SA20 type), flange connection type (FA20 type) three ways, the maximum
working pressure and the maximum operating temperature of the same size were higher than the original LZB/LZJ series
glass rotor flowmeter. The product has high accuracy and good for the interchange function, wide flow range and
connection mode, the advantages of easy installation and maintenance, FA20 flange rotating type flowmeter, in
accordance with the piping flange hole.
The product can also according to different fluid temperature, pressure, density, viscosity, and other physical quantities,
to provide users with different fluid flow scale, the different status, solve the problem of fixed value, greatly facilitate the
use of the user, alternative to turn the instrument on the introduction of complete sets of equipment, widely used in
chemical industry, light industry, pharmacy, food, paper making, environmental protection and measurement test,
scientific research departments, measurement or single phase of pulsating flow of fluid (liquid or gas).
LZB-GA24 Glass Tube Rotameter
Technical Parameters
Measure Range Water (20oC) 4-36000 l/h
Air (20oC) 101325 Pa ; 12-300 m3/h
Range of Degrees 10 : 1
The Accuracy Level 1.6
Taper Pipe Length 300 mm
Scale mm scale and flow scale
By Current Body Condition Maximum Pressure DN15-25: 1.0 MPa
DN40: 0.9 MPa
The Highest Temperature 120oC
Specifications
Model Measure Range
Nominal Loss of Pressure
Diameter The Corrosion Water Air (Pa)
Ordinary
Type (20oC, l/h) (20oC, 101325 Pa, m3/h)
Summary
GA24 type glass rotameter is adopting international technology and equipment manufacturing products, for the flange
connection, the maximum working pressure and the maximum working temperature of the same size were higher than
original LZB/LZJ series glass rotor flowmeter. The product has high accuracy and good for the interchange function, wide
flow range and connection mode, the advantages of easy installation and maintenance, flange rotating flowmeter,
consistent with the piping flange holes, unique explosion-proof glass protective mask, don’t have to be removed from the
pipeline cone tube and float can be easily replaced.
The product can also according to different fluid temperature, pressure, density, viscosity and other physical quantities,
to provide users with different fluid flow scale, the different status, solve the problem of fixed value, greatly facilitate the
use of the user, alternative to turn the instrument on the introduction of complete sets of equipment, widely used n
chemical industry, light industry, pharmacy, food, paper making, environmental protection and measurement test,
scientific research departments, measurement or single phase of pulsating flow of fluid (liquid or gas).
LZB-WA30S Glass Tube Rotameter
Summary
All stainless steel type, the flowmeter shell adopts 304 stainless steel seamless steel tube, interface female connection
respectively, and who live flange connection fast loading end, beautiful and practical, easy to clean.
Specifications
Range
Nominal Working
Model Water Air Accuracy Temperature
Diameter o Pressure
(20 C, l/h) (20 C, 101325 Pa, m3/h)
o
4-40 6.3-63
0.12-1.2
10-100 12-120 0.2-2
0.3-3
VA 30S-15 16-160 20-200 0.4-4
0.5-5
15 SA 30S-15 25-250 30-300 0.6-6
0.8-8
FA 30S-15 36-360 40-400 0.9-9
1.2-12
46-460 63-630 2-20
≤ 1.0 MPa
65-650 75-750
4-400 50-500
1.6-16 2-20
VA 30S-25 63-630 80-800
2.5-25 3-30
25 SA 30S-25 100-1000 120-1200 ± 1.5%
4-40 5-50 -20oC - +120 oC
FA 30S-25 160-1600 200-2000
6-60
250-2500 300-3000
VA 30S-40 160-1600 200-2000 5-50
6-60
40 SA 30S-40 250-2500 300-3000 8-80 ≤ 0.9 MPa
9-90
FA 30S-40 400-4000 500-5000 12-120
250-2500 300-3000
VA 30S-50 400-4000 500-5000 10-100
12-120
50 SA 30S-50 630-6300 800-8000 16-160 ≤ 0.7 MPa
20-200
FA 30S-50 1000-10000 1500-15000 30-300
4000-16000
Technical Parameters
Nominal Measurement Range
Working Pressure
Diameter Water (L/h) Air (L/min)
30-300 10-100
15 60-600 20-200
80-800 25-250
90-900 20-200
20 120-1200 30-300
180-1800 50-500
≤ 0.8 MPa
180-1800 50-500
25 300-3000 100-1000
480-4800 150-1500
480-4800 200-2000
32 600-6000 250-2500
720-7200 300-3000
1-10 m3/h 18-180 Nm3/h
40 1.2-12 m3/h 20-200 Nm3/h
1.5-15 m3/h 25-250 Nm3/h
1.2-12 m3/h 20-200 Nm3/h
50 1.5-15 m3/h 25-250 Nm3/h ≤ 0.6 MPa
1.8-18 m3/h 30-300 Nm3/h
1.8-18 m3/h 25-250 Nm3/h
65 3-30 m3/h 35-350 Nm3/h
4-40 m3/h 40-400 Nm3/h
4-40 m3/h 40-400 Nm3/h
80 5-50 m3/h 50-500 Nm3/h
6-60 m3/h 60-600 Nm3/h Stainless steel 304 material,
≤ 0.4 MPa
3
6-60 m /h 60-600 Nm /h3 flange connection, withstand
100 7-70 m3/h 70-700 Nm3/h 120OC high temperature, the
glass shell is unbreakable
10-100 m3/h 90-900 Nm3/h
Measuring Range
Air (m3/h)
Water (L/h)
Diameter 20OC Max Pressure Loss (KPa) Working
20OC 101325Pa Accuracy
(mm) 101325Pa.abs Pressure
RR0 RR1 RL PTFE RR0 RR1 RRL RRO RR1 RRL PTFE
1.6-16 0.05-0.5 6.5
2.5-25 0.07-0.7 6.5
4-40 2.5-25 0.12-1.2 6.5 5.5
6-60 4-40 0.18-1.8 6.6 5.5
15
10-100 6-60 0.3-3 6.6 5.6 ±1.5% ≤4.0Mpa
16-160 10-100 0.4-4.0 6.8 5.8
25-250 16-160 0.7-7.0 7.2 6.1
40-400 25-250 1.0-10 8.6 6.1
60-600 40-400 1.5-15 11.1 7.3
80-800 60-600 2.5-25 11.1 7.3
100-1000 80-800 3.0-30 11.1 7.3
40-400 40-400 0.75-7.5 8.6 6.1
20 60-600 60-600 1.2-12 11.1 7.3
100-1000 100-1000 1.8-18 11.1 7.3
40-400 40-400 1-10 6.5 5.9
60-600 50-500 1.5-15 6.5 6.2
80-800 60-600 2.5-25 7.0 7.0
100-1000 80-800 4-40 7.0 5.9
25 160-1600 100-1000 5-50 8.0 6.0
250-2500 160-1600 6-60 10.8 6.8
400-4000 250-2500 8-80 15.8 9.2
≤4.0Mpa
500-5000 400-4000 10-100 16.2 11.0
600-6000 500-5000 15-150 16.5 12.0
160-1600 160-1600 3.0-30 8.0 6.0
250-2500 250-2500 5.0-50 10.8 6.8
32
400-4000 400-4000 7.5-75 15.8 9.2
600-6000 600-6000 16.5 12.0
400-4000 400-4000 3.0-30 8.0 6.5
40 600-6000 600-6000 5.0-50 11 6.8
1000-15000 1000-10000 7.5-75 16.2 9.4
600-6000 400-4000 18-180 8.0 6.5
1000-10000 600-6000 25-250 11.0 6.8 ±1.5%
50 1600-16000 1000-10000 40-400 16.2 9.4
2000-20000 1600-16000 50-500 17.0 14.5
2500-25000 2000-20000 60-600 19.0 16.5
1200-12000 1200-12000 18-180 8.2 6.9
65 1600-16000 1600-16000 30-300 8.2 6.9
2500-25000 2500-25000 37-370 15.5 11.9
1600-16000 1000-10000 50-500 8.2 6.9
2500-25000 1600-16000 60-600 15.5 11.9
80
4000-40000 2000-20000 100-1000 20.0 16.1
5000-50000 2500-25000 150-1500 25.0 18.1
4000-40000 2000-20000 100-1000 8.4 8.1
≤1.6Mpa
5000-50000 2500-25000 150-1500 11.2 9.1
100 6000-60000 4000-40000 180-1800 20.0 16.5
8000-80000 5000-50000 240-2400 25.4 22.2
10000-100000 8000-80000 300-3000 32 29.2
10000-100000 8000-80000 300-3000 42 38.5
125
25000-250000 10000-100000 45 42
12500-125000 10000-100000 45 42
150
15000-150000 12500-125000 60 58
LZ-Outline and Installing Dimension (Flange Connection)
Flange Connection
DN H L L1
15 250 160 80
20 250 160 80
25 250 160 89
32 250 160 91
40 250 160 91
50 250 160 104
65 250 160 104
80 250 160 130
100 250 160 137
125 250 160 137
Y10 Bottom-Top (Flange Connection)
150 300 160 157
Summary
Stable magnetic field, the special magnetic circuit structure, make its have strong outside interference resistance, widely
used in chemical industry, electric power, smelting, mining, oil, sewage, medical food industry such as measurement and
control of conductive liquid.