Operating manual
OnC FlowSens 604
Magnetic Flowmeter
FS604: DN 2.5…3000 Standard
OnC FlowSens 604
Copyright
Copyright by Voith Paper Automation GmbH & Co. KG. No part of this publication may be reproduced, stored
in a retrieval system, or transmitted in any form or by any means, graphic, electronic, mechanical,
photocopying, recording, taping, or otherwise without the prior permission of the copyright owner.
We keep the right to do any technical changes which are necessary to improve the product without prior
notice.
System supplier
Voith Paper Automation GmbH & Co. KG
Department sea895
Escher-Wyss-Str. 25
88212 Ravensburg
Germany
Tel. +49 (751) 83-2991
Fax +49 (751) 83-2982
Internet: http://www.voith.com
Contents
1 Preliminary remarks 5
2 Safety 6
3 Device description 11
4 Installation 13
4.5.12 Temperatures...................................................................................................................... 19
4.6 Mounting......................................................................................................................... 20
4.6.1 Torques and pressures ......................................................................................................... 20
5 Electrical connections 23
6 Service 25
7 Technical data 28
8 Notes 40
1 Preliminary remarks
To enable you to find quickly and reliably in the operation manual, this section familiarises you
with the structure of the operation manual.
This manual uses symbols and special characters which make it easier for you to find
information. Please read the explanations of the symbols given in the section below. Ensure that
you read all the safety instructions in this operation manual very carefully. You will find safety
instructions in section 2, in the foreword to the sections and before any working instructions.
DANGER!
This information refers to the immediate danger when working with electricity.
DANGER!
This warning refers to the immediate danger of burns caused by heat or hot surfaces.
DANGER!
These warnings must be observed without fail. Even partial disregard of this warning can lead to
serious health problems and even death. There is also the risk of seriously damaging the device
or parts of the operator's plant.
WARNING!
Disregarding this safety warning, even if only in part, poses the risk of serious health problems.
There is also the risk of damaging the device or parts of the operator's plant.
CAUTION!
Disregarding these instructions can result in damage to the device or to parts of the operator's
plant.
INFORMATION!
These instructions contain important information for the handling of the device.
• HANDLING
This symbol designates all instructions for actions to be carried out by the operator in the
specified sequence.
i RESULT
This symbol refers to all important consequences of the previous actions.
2 Safety
2.1 General safety instructions
CAUTION!
Installation, operation and maintenance of the products are always subject to the local safety
and accident prevention regulations!
2.1.1 State-of-the-art
This product has been built by Voith Paper Automation GmbH & Co. KG in accordance with state-
of-the-art standards and the recognized safety rules.
The product satisfies the safety requirements defined in the pressure equipment directive.
Nevertheless, its use may constitute a risk to life and limb of the user or of third parties, or cause
damage to the product and to other material property, if:
CAUTION!
Therefore, every person involved in installing, operating and servicing the product must read,
understand and observe the complete operating instructions, particularly the safety
instructions.
CAUTION!
Rectify immediately any functional disorders, especially those affecting the safety of the product.
must be observed.
INFORMATION!
Particular data to the operation and limit values are specified in the chapter "Technical data".
CAUTION!
The operating values, limit values and setting data must not deviate from the values specified in
the operation manual and corresponding information sheet without consulting the
manufacturer! The manufactuer cannot be held liable for any damages resulting from non-
observance of the operation manual.
2.3.3 Checks
Periodically check that the personnel carry out the work in compliance with the operation
manual and that they pay attention to risks and safety factors.
CAUTION!
Only media may be metered by the flow sensor for which assurance is available that the
chemical and physical properties of the media wetted parts (electrodes, liner, grounding and
protection rings, flange gaskets etc) will not be adversely affected.
DANGER!
Do not exceed the design data of the flow sensor!
The operating pressure must not exceed the permitted nominal pressure declared on the name
plate. Exceeding the design data may lead to damage and uncontrolled escape of the
pressurized medium and may cause severe or fatal injuries.
WARNING!
When transporting and handling the flow sensor, observe ist weight.
Place the hoisting ropes securely around the body of the flow sensor.
The flow sensor may injure persons if dropped.
Do not walk under suspended loads.
CAUTION!
Potentially installed protection rings at the prozess connections are intended to protect the liner
during transport and installation, these may not be removed.
CAUTION!
In case of installation works above headroom use suitable step-ladders or service platforms. Do
not use the flow sensor as a step tread.
CAUTION!
The flow sensor must be installed in stress-free manner with parallel, concentric mating
flanges. The used flange gaskets must be suitable for the operating conditions (kind of media,
media temperature etc.). All flange bolts must be tightened to the specified max. torque value.
DANGER!
All work on the electrical connections may only be carried out with the power disconnected. Take
note of the voltage data on the nameplate!
DANGER!
Observe the national regulations for electrical installations!
DANGER!
Electrical connection is carried out in conformity with the VDE 0100 directive "Regulations for
electrical power installations with line voltages up to 1000 V" or equivalent national regulations.
DANGER!
The device must be grounded in accordance with regulations in order to protect personnel
against electric shocks.
DANGER!
There should be no difference in potential between the measuring sensor and the housing or
protective earth of the signal converter!
DANGER!
In case of metering hot media, touching the housing of the flow sensor or attached components
may cause burns.
DANGER!
Do not dismantle or remove the flow sensor from the line as long as the flow sensor is
pressurized! Depressurize the relevant flow sensor, shut off the line segment where the flow
sensor is installed and remove the medium, before opening the flange bolts at the flow sensor.
DANGER!
Inform yourself of the properties of the medium transported by the flow sensor before
performing installation or maintenance works or dismantling the flow sensor.
Observe the safety instructions in the safety data sheets of the manufacturers.
Protect yourself and your environment from hazardous or poisonous substances.
CAUTION!
Protect yourself against noise if a high noise level near by the installation area of the flow sensor
is existing.
3 Device description
3.1 Scope of delivery
1 Remote version
2 Compact version with UC 600 signal converter
3.2 Nameplates
INFORMATION!
Look at the device nameplate to ensure that the device is delivered according to your order.
Check for the correct supply voltage printed on the nameplate.
4 Installation
4.1 Safety instructions on installation
DANGER!
When performing installation works take care of the safety instructions in section 2, especially
section 2.5.
INFORMATION!
Check the packing list to check if you received completely all that you ordered.
INFORMATION!
Look at the device nameplate to ensure that the device is delivered according to your order.
Check for the correct supply voltage printed on the nameplate.
4.3 Storage
• Store the device in a dry and dust-free location.
• Avoid lasting direct exposure to the sun.
• Store the device in its original packing.
4.4 Transport
INFORMATION!
Sensors of type VN02 up to DN10:
The inlet and outlet sections are enclosed inside the sensor.
4.5.4 T-section
4.5.5 Vibration
4.5.7 Bends
4.5.11 Pump
4.5.12 Temperatures
CAUTION!
Protect the device from direct sunlight.
Temperature range Process [°C] Ambient [°C] Process [°F] Ambient [°F]
PTFE
Separate flow sensor -40 180 -40 65 -40 356 -40 149
Compact with UC 600 -40 140 -40 65 -40 284 -40 149
PFA
Separate flow sensor -40 180 -40 65 -40 356 -40 149
Compact with UC 600 -40 140 -40 65 -40 284 -40 149
ETFE
Separate flow sensor -40 120 -40 65 -40 248 -40 149
Compact with UC 600 -40 120 -40 65 -40 248 -40 149
4.6 Mounting
4.6.1 Torques and pressures
Tighten the bolts in fixed order, see picture:
1 Step 1: Apply approx. 50% of max. torque given in table.
2 Step 2: Apply approx. 80% of max. torque given in table.
3 Step 3: Apply 100% of max. torque given in table.
INFORMATION!
Diameters with more holes per flange, please continue in the same way to tighten the other
bolts.
5 Electrical connections
5.1 Safety instructions
DANGER!
All work on the electrical connections may only be carried out with the power disconnected. Take
note of the voltage data on the nameplate!
DANGER!
Observe the national regulations for electrical installations!
WARNING!
Observe without fail the local occupational health and safety regulations. Any work done on the
electrical components of the measuring device may only be carried out by properly trained
specialists.
INFORMATION!
Look at the device nameplate to ensure that the device is delivered according to your order.
Check for the correct supply voltage printed on the nameplate.
5.3 Grounding
DANGER!
The device must be grounded in accordance with regulations in order to protect personnel
against electric shocks.
Possible if:
≥ DN10
Electrical conductivity ≥ 200 µS/cm
6 Service
6.1 Safety instructions
WARNING!
The flow sensor may only be installed, commissioned, operated and maintained by properly
trained and authorized personnel.
DANGER!
All work on the electrical connections may only carried out with the power disconnected.
DANGER!
Do not dismantle or remove the flow sensor from the line as long as the flow sensor is
pressurized.
Depressurize the relevant flow sensor, shut off the line segment where the flow sensor is
installed and remove the medium, before opening the flange bolts at the flow sensor.
DANGER!
Inform yourself of the properties of the medium transported by the flow sensor before
performing installation or maintenance works or dismantling the flow sensor.
Observe the safety instructions in the safety data sheets of the manufacturers.
Protect yourself and your environment from hazardous or poisonous substances.
DANGER!
In case of metering hot media, touching the housing of the flow sensor or attached components
may cause burns.
WARNING!
When transporting and handling the flow sensor, observe its weight.
Place the hoisting ropes securely around the body of the flow sensor.
The flow sensor may injure persons if dropped.
Do not walk under suspended loads.
CAUTION!
In case of installation works above headroom use suitable step-ladders or service platforms.
Do not use the flow sensor as a step tread.
CAUTION!
Protect yourself against noise if a high noise level near by the installation area of the flow sensor
is existing.
6.2 Maintenance
The flow sensor, used for the intended purpose, is essentially maintenance-free.
• ambient conditions,
• tightness of flange bolts,
• condition of electrical connections,
• functional liability and
• grounding.
If defects occur during the warranty period, please get in touch with the contact person named
on the order confirmation.
CAUTION!
Should you nevertheless need to return a device for inspection or repair, please pay strict
attention to the following points:
• Due to statutory regulations on environmental protection and safeguarding the health and
safety of our personnel, manufacturer may only handle, test and repair returned devices that
have been in contact with products without risk to personnel and environment.
• This means that the manufacturer can only service this device if it is accompanied by the
following certificate (see next section) confirming that the device is safe to handle.
CAUTION!
If the device has been operated with toxic, caustic, flammable or water-endangering products,
you are kindly requested:
• to check and ensure, if necessary by rinsing or neutralizing, that all cavities are free from
such dangerous substances,
• to enclose a certificate with the device confirming that is safe to handle and stating the
product used.
Company: Address:
Department: Name:
We hereby confirm that there is no risk to persons or the environment through any residual media
contained in the device when it is returned.
Date: Signature:
Stamp:
6.4 Disposal
CAUTION!
Disposal must be carried out in accordance with legislation applicable in your country.
7 Technical data
7.1 Measuring principle
An electrically conductive fluid flows inside an electrically insulating pipe through a magnetic
field. This magnetic field is generated by a current, flowing through a pair of field coils. Inside of
the fluid, a voltage U is generated:
U=v*k*B*D
in which:
v = mean flow velocity
k = factor correcting for geometry
B = magnetic field strength
D = inner diameter of flow meter
The signal voltage U is picked off by electrodes and is proportional to the mean flow velocity v
and thus the flow rate q. The signal voltage is quite small (typically 1 mV at v = 3 m/s / 10 ft/s and
field coil power of 1 W). Finally, a signal converter is used to amplify the signal voltage, filter it
(separate from noise) and convert it into signals for totalising, recording and output processing.
Measuring system
Measuring principle Faraday's law
Application range Electrically conductive fluids
Measured value
Primary measured value Flow velocity
Secondary measured value Volume flow, mass flow, electrical conductivity, coil temperature
Design
Features Flange version with full bore flow tube
Standard as well as higher pressure ratings
Broad range of nominal sizes
Industry specific insertion lengths
Modular construction The measurement system consists of a flow sensor and a signal
converter. It is available as compact and as separate version. More
information about the signal converter can be found in the
documentation of the signal converter.
Compact version With UC 600 converter
Remote version In field (F) or wall (W) mount version with UC 600 converter
Nominal diameter With UC 600 converter: DN2.5...3000 / 1/10...120"
Measurement range -12...+12 m/s / -40...+40 ft/s
Measuring accuracy
Reference conditions Medium: water
Temperature: 20°C / 68°F
Inlet section: 10 DN
Outlet section: 5 DN
Flow velocity: > 1 m/s / > 3 ft/s
Operating pressure: 1 bar / 14.5 psig
Valve closing time variation: < 1 ms
Wet calibrated on EN 17025 accredited calibration rig by direct
volume comparison
Maximum measuring error Related to volume flow (MV = Measured Value)
These values are related to the pulse / frequency output
The additional typical measuring deviation for the current output is
±10 μA
With UC 600 converter:
DN2.5...6: ± 0.3% of MV + 2 mm/s
DN10...1600: ± 0.2% of MV + 1 mm/s
DN1800...3000: ± 0.3% of MV + 2 mm/s
Repeatability ±0.1% of MV, minimum 1 mm/s
Long term stability ±0.1% of MV
Special calibration Better accuracies optional
Operating conditions
Temperature
Process temperature Temperature depends on the liner material.
PTFE: -40...+180°C / -40...+356°F (remote versions, compact versions
are limited to +140°C / 284°F).
PFA: -40...+180°C / -40...+356°F (remote versions, compact versions
are limited to +140°C / 284°F ).
ETFE: -40...+120°C / -40...+248°F
For detailed information see chapter "Temperatures".
Ambient temperature -40…+65°C / -40…+149°F
Storage temperature -50…+70°C / -58…+158°F
Pressure
Ambient Atmospheric
Nominal flange pressure Information for sizes larger than DN2000 / ASME80" on request.
DIN (EN 1092-1) Standard:
PN6 for DN1200...2000
PN10 for DN200...1000
PN16 for DN65 and DN100...150
PN40 for DN2.5...50 and DN80
Option:
PN10 for DN1200...2000
PN16 for DN200...2000
PN25 for DN65 and DN100...1000
PN40 for DN65 and DN100...600
Other pressures on request
ISO insertion length Optional for DN15...600
ASME B16.5 Standard:
150 lbs RF for ASME1/10...24"
Option:
300 lbs RF for ASME1/10...24"
600 lbs RF for ASME3/8...24"
900 lbs RF for ASME3/8...12"
1500 lbs RF for ASME3/8...12"
Other pressures on request
JIS Standard:
10 K for DN50...1000
20 K for DN2.5...40
Option:
20 K for DN200...600
Other pressures on request
Vacuum load For information on pressure limits depending on liner material see
chapter "Vacuum load".
Pressure ranges for secondary Pressure resistant up to 40 bar / 580 psi
containment
Burst pressure up to approx. 160 bar / 2320 psi
Chemical properties
Physical condition Liquids
Electrical conductivity Water: ≥ 20 μS/cm
Non water: ≥ 1 μS/cm
Permissible gas content (volume) ≤ 5%
Permissible solid content ≤ 70%
(volume)
Recommended flow velocity -12...+12 m/s / -40...+40 ft/s
Other conditions
Protection category acc. to IEC Standard: IP 66/67 (NEMA 4/4X/6)
529 / EN 60529
Optional: IP 68 (NEMA 6P)
Vibration resistance IEC 68-2-6
Random vibration test IEC 68-2-34
Shock test IEC 68-2-27
Installation condtitions
Inlet run ≥ 5 DN (without disturbing flow, after a single 90° bend)
≥ 10 DN (after a double bend 2x 90°)
≥ 10 DN (behind a control valve)
Outlet run ≥ 2 DN
Dimensions and weights For detailed information see chapter "Dimensions and weights".
Materials
Sensor housing DN2.5...15: Stainless steel 1.4408
DN20: GTW-S 30
DN25...2000: Standard sheet steel, optional stainless steel 304
(1.4306)
Other materials on request.
Flange Standard: carbon steel, PU coated
Option: stainless steel
Other materials on request
Liner PTFE: standard for DN20, optional for DN200...600
PFA: standard for DN2.5...6 and DN25...150
ETFE: standard for DN200...2000
Other materials on request.
Grounding rings Stainless steel, Hastelloy® C, Titanium, Tantalum
Other materials on request
Also available as alternative for grounding rings : Virtual Reference.
Connection box F versions only
Standard: Aluminum, polyurethane coated
Option: Stainless steel 304 (1.4306)
Measuring electrodes Standard: Hastelloy® C
Option: Platinum, Stainless steel, Titanium, Tantalum (DN2.5...1200),
low noise Hastelloy® C4 (DN10...2000), Low noise SS 316 Ti (1.4571)
(DN10...2000)
Other materials on request.
Grounding electrodes (option) Same material as measuring electrodes.
Process connections
DIN DN2.5...3000 in PN 2.5...40 (others on request)
ASME 1/10...120" in 150...2500 lbs RF (others on request)
JIS DN2.5...1000 in JIS 10...20 K (others on request)
Design of gasket surface RF (others on request)
Electrical connections
Signal cable Only for remote systems
Type A Standard cable, double shielded.
Max. length: 600 m / 1950 ft (dep. on electrical conductivity and
measuring sensor). See documentation of the converter for more
information.
Type B Optional cable, triple shielded.
Max. length: 600 m / 1950 ft (dep. on electrical conductivity and
measuring sensor). See documentation of the converter for more
information.
[mm] [bar] 40°C 60°C 70°C 80°C 90°C 100°C 120°C 140°C 180°C
Liner in PFA
DN2.5...150 50 0 0 0 0 0 0 0 0
Liner in ETFE
DN200...2000 150 100 100 100 100 100 100 100 - -
Liner in PTFE
DN10...20 50 0 0 0 0 0 0 500 750 1000
DN200...300 50 500 750 1000 1000 1000 1000 1000 1000 1000
DN350...600 50 800 1000 1000 1000 1000 1000 1000 1000 1000
[inches] [psi] 104°F 140°F 158°F 176°F 194°F 212°F 248°F 284°F 356°F
Liner in PFA
1/10...6" 725 0 0 0 0 0 0 0 0 0
Liner in ETFE
8...72" 2176 1.5 1.5 1.5 1.5 1.5 1.5 1.5 - -
Liner in PTFE
3/8...3/4" 725 0 0 0 0 0 0 7.3 10.9 14.5
8...12" 725 7.3 10.9 14.5 14.5 14.5 14.5 14.5 14.5 14.5
14...24" 725 11.6 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5
INFORMATION!
• All data given in the following tables are based on standard versions of the sensor only.
• Especially for smaller nominal sizes of the sensor, the converter can be bigger than the
sensor.
• Note that for other pressure ratings than mentioned, the dimensions may be different.
• For full information on converter dimensions see relevant documentation.
DIN/ISO flanges
Nominal size Dimensions [mm] Approx.
weight [kg]
DN PN [bar] L H W
DIN ISO
2.5 40 130 - 142 90 3
4 40 130 - 142 90 3
6 40 130 - 142 90 3
10 40 130. - 106 90 6
15 40 130. 200 106 95 6
20 40 150 200 158 105 7
25 40 150 200 140 115 5
32 40 150 200 157 140 6
40 40 150 200 166 150 7
50 40 200 200 186 165 11
65 16 200 200 200 185 9
80 40 200 200 209 200 14
100 16 250 250 237 220 15
125 16 250 250 266 250 19
150 16 300 300 300 285 27
200 10 350 350 361 340 34
250 10 400 450 408 395 48
300 10 500 500 458 445 58
350 10 500 550 510 505 78
400 10 600 600 568 565 101
450 10 600 - 618 615 111
500 10 600 - 671 670 130
600 10 600 - 781 780 165
700 10 700 - 898 895 248
800 10 800 - 1012 1015 331
900 10 900 - 1114 1115 430
1000 10 1000 - 1225 1230 507
1200 6 1200 - 1417 1405 555
1400 6 1400 - 1619 1630 765
1600 6 1600 - 1819 1830 1035
1800 6 1800 - 2027 2045 1470
2000 6 2000 - 2259 2265 1860
CAUTION!
• Pressures are applicable at 20°C / 68°F.
• For higher temperatures, the pressure and temperature ratings are as per ASME B16.5 (up to
24") or ASME B16.47 (>24").
• Dimensions for other sizes on request.
CAUTION!
• Pressures are applicable at 20°C / 68°F.
• For higher temperatures, the pressure and temperature ratings are as per ASME B16.5 (up to
24") or ASME B16.47 (>24").
• Dimensions for other sizes on request.