HiMAP-MC Hyundai Intelligent Measuring and Protection Device - Motor Controller
Characteristics
Protects motor safely through the built-in functions Check the operation status that displays simple
of Over-current, Under-current, Phase-fail, Reverse- phased voltage, 3-phased current and load factor
phase, Imbalanced, Stall/Locked Rotor, Earth fault via simple button control
protection
Easy to set the starting mode by selecting a fixed- Check faults and major operation event lists by
type starting method in configuration menu or logic storing all types of accidents and major events
editing at user mode
The display and control panels are separated and A variety of functions are available through the
attached in front of the main panel in order to be exclusive Manager and Ladder program.
able to control the motor and examine faults
operating values, and fault currents. Operations can
be changed by simple button control without Communication Functions
removing the unit
By adding the MODBUS-RTU protocol in the RS-485
communication port, it is possible to remotely send
information and control the system
Fault & Fault Current Display
HiMAP-MC
4
HiMAP-MC
HiMAP-MC Manager
The HiMAP-MC Manager is an operation program that helps to change revision values of relay factors, analyze
events, monitor current status values and control motors via a PC.
The HiMAP-MC Manager operates with an RS232 interface in the front communication port and is compatible
with Windows 2000, XP and higher version of OS.
The resolution is optimized to 1280x1024, but is also able to run at 1024x768.
This program runs on a full screen.
Setting values in the HiMAP-MC is done by It is possible to check all kinds of event data and
downloading and modifying them at one time. fault records, saved in HiMAP-MC, on one screen.
It is easy to check the status information and By using mode setting, the motor can be controlled
important measurement values of HiMAP-MC in real directly by the Manager as well as HiMAP-MC.
time.
5
HiMAP-MC Hyundai Intelligent Measuring and Protection Device - Motor Controller
ezLadder Program
Users who also use ezLadder can operate a variety of desired logic functions by downloading modified
logic programs into HiMAP-MC.
6
HiMAP-MC
Functions
Motor Protection
7
HiMAP-MC Hyundai Intelligent Measuring and Protection Device - Motor Controller
Functions
Instantaneous Power Fail & Restart Various Remote Control / Monitoring Systems
Ten seconds after instantaneous power failure Due to its simple sequence, HiMAP-MC can monitor
occurs, the motors will re-start. and control motors via remote communication by
However, this can cause serious damage to the PLC or DCS.
motors. To prevent damages, set the motors to You can transmit Ladder Logic Data from a PC to
restart individually. your HiMAP-MC using the Logic Sequence Editor.
HiMAP-MC maintains the operating state (run/stop, For instance, after completing drawing of Ladder
reverse) and remote control state (Local, MCC, Logic and download to HiMAP-MC, HiMAP-MC will
Auto, Remote) prior to the power failure. be operated in compliance with sequence of the
drawing.
Communication
8
HiMAP-MC
Specifications
Rating
Item Specifications
Panel Seperate type
Chracteristic Inverse/Definite
Phase Current 3 CT 0.1-120A
option
Zero Phase Current ZCT 0.03-3A (Using private ZCT)
Input Rating DC Analog Inputoption DC 4-20mA (Monitoring temperature of motor)
Voltage 1 PT 0-380V
Frequency 50/60Hz
Inverse 1-60 seconds
Time Setting
Return Time Instant manual return (Push RESET button or turn off the control power)
Voltage AC 85-264V, DC 24V
Control Power Frequency 50/60Hz
Power Consumption Under 6W
Capacity AC 250V/10A (4EA), AC 250V/5A (3EA) Resistor load.
Composition Operating Contact 3a Foward/Reverse, Y-△, reactor, inverter start
Output Contact
State Contact 3a Local, MCC, Auto-state indication
Trip Contact 1a Fault output
External Operation (5EA) AC 220V Run/Stop, reverse, return, local switch input
Input Contact
MC State (1EA) AC 220V Monitoring sequence (LED flickering)
3-Phase current, trip cause, setting value, setting item, running time,
LCD 16 Character×2 Row
Display 4-20mA, unbalance rate, load rate, zero-phase current, single-phase current
LED 9EA Operating state, operating mode, trip, system fail, communication fail
Self-Diagnosis System fail LED
Communication MODBUS-RTU (RS-485)
Installation Inside panel
Cable 0.8m
Weight 1.2kg Display part (0.3kg)/Main unit (0.65kg)/CT (0.25kg)
Display 143 (W)×101 (H)×26.8 (D)mm
Dimensions Main Unit 84 (W)×115 (H)×102.5 (D)mm
3 CT 51.6 (W)×109.8 (H)×34 (D)mm
Environment
Item Range
Operating: -10-55℃
Temperature
Storage: -20-70℃
Humidity Under 80%
Other Altitude: below 2000m sea level
9
HiMAP-MC Hyundai Intelligent Measuring and Protection Device - Motor Controller
View
Display Module
State Display
(Self-Diagnosis Trip Operating State Display
Communication)
Selection and
Front Comm. Port Move Keys
Control Module
Power
Communication
1Ph PT, 4-20mA
Output Contact
Input
Input Contact
Connetion with
Display Module
3Ph CT, ZCT Input
Debugging Port
10
HiMAP-MC
System Set-up
HiMAP
SCADA
Ethernet-TCP/IP
HICM-PC (II)
MODBUS-RTU (RS-485)
11
12
HiMAP-MC
Direct Start
Connection Diagrams
Hyundai Intelligent Measuring and Protection Device - Motor Controller
Notes
1) Digital Input (TB4) 3) RLY Output (TB3)
22, 23, 24, 25, 26, 27 (signal), 10-11 (Trip), 12-15 (88M/88F/88H),
28, 29 (DI-com) 13-15 (88D/88R/88Re/88L), 14-15 (88Y),
2) Communication (TB2) 16-17 (LOP), 18-19 (MCC), 20-21 (Auto/Remote)
4, 5, 6, 7, 8, 9 (RS-485) 4) Analog Input (TB5)
36, 37 (1Φ PT)
40, 41 (4-20mA)
Y-Delta Start
Notes
1) Digital Input (TB4) 3) RLY Output (TB3)
22, 23, 24, 25, 26, 27 (signal), 10-11 (Trip), 12-15 (88M/88F/88H),
28, 29 (DI-com) 13-15 (88D/88R/88Re/88L), 14-15 (88Y),
2) Communication (TB2) 16-17 (LOP), 18-19 (MCC), 20-21 (Auto/Remote)
4, 5, 6, 7, 8, 9 (RS-485) 4) Analog Input (TB5)
36, 37 (1Φ PT)
40, 41 (4-20mA)
13
HiMAP-MC
14
HiMAP-MC
Forward-Reverse Start
Connection Diagrams
Hyundai Intelligent Measuring and Protection Device - Motor Controller
Notes
1) Digital Input (TB4) 3) RLY Output (TB3)
22, 23, 24, 25, 26, 27 (signal), 10-11 (Trip), 12-15 (88M/88F/88H),
28, 29 (DI-com) 13-15 (88D/88R/88Re/88L), 14-15 (88Y),
2) Communication (TB2) 16-17 (LOP), 18-19 (MCC), 20-21 (Auto/Remote)
4, 5, 6, 7, 8, 9 (RS-485) 4) Analog Input (TB5)
36, 37 (1Φ PT)
40, 41 (4-20mA)
Reactor Start
Notes
1) Digital Input (TB4) 3) RLY Output (TB3)
22, 23, 24, 25, 26, 27 (signal), 10-11 (Trip), 12-15 (88M/88F/88H),
28, 29 (DI-com) 13-15 (88D/88R/88Re/88L), 14-15 (88Y),
2) Communication (TB2) 16-17 (LOP), 18-19 (MCC), 20-21 (Auto/Remote)
4, 5, 6, 7, 8, 9 (RS-485) 4) Analog Input (TB5)
36, 37 (1Φ PT)
40, 41 (4-20mA)
15
HiMAP-MC
16
HiMAP-MC
Two-Speed Starting
Connection Diagrams
Hyundai Intelligent Measuring and Protection Device - Motor Controller
Notes
1) Digital Input (TB4) 3) RLY Output (TB3)
22, 23, 24, 25, 26, 27 (signal), 10-11 (Trip), 12-15 (88M/88F/88H),
28, 29 (DI-com) 13-15 (88D/88R/88Re/88L), 14-15 (88Y),
2) Communication (TB2) 16-17 (LOP), 18-19 (MCC), 20-21 (Auto/Remote)
4, 5, 6, 7, 8, 9 (RS-485) 4) Analog Input (TB5)
36, 37 (1Φ PT)
40, 41 (4-20mA)
HiMAP-MC
TB5 (Analog Input) TB4 (Digital Input) TB3 (Digital Output) TB1 (Control Power)
36 PT V_U1 22 DI1 10 DO1 1 AC-L (+)
37 PT V_U2 23 DI2 11 COM1 2 AC-N (-)
38 n.a. 24 DI3 12 DO2 3 FG
39 n.a. 25 DI4 13 DO3
40 AI+ (4-20mA) 26 DI5 14 DO4 TB2 (Communication)
41 AI- (4-20mA) 27 DI6 15 COM2 4 Vp
28 Common 16 DO5 5 Vn
29 Common 17 COM3 6 SGND
18 DO6 7 Vp
19 COM4 8 Vn
20 DO7 9 SGND
21 COM5
CN2 (Analog Input)
30 IR
31 IS
32 IT
33 Icommon
34 ZCT_K
35 ZCT_L
17
HiMAP-MC Hyundai Intelligent Measuring and Protection Device - Motor Controller
How to Order
HiMAP - MC - 1 - 2 - 3options
Example) HiMAP-MC-1-6-X
Power Rated Frequency Options
1: AC 110V power
1 AC 110V 5 50Hz X None 6: 60Hz
2 AC 220V 6 60Hz A AI (4-20mA) X: Options
Dimensions
Display Module
Unit: mm
119
16.8
26.8
143 131
121
93
60
101
101
91
4-M4mm tap
143
(Cutting Size)
18
HiMAP-MC
Control Module
Unit: mm
115 86.49
86.49
102.5
102.5
28.8
32.8
115
CT Module
Unit: mm
34
30.5
54 34 34
29.3 24.7 27 20.5
10
20.6
20.6
27
F F
35.5
35.5
14.1
121.2
71
35.5
35.5
H-H
4
8
17
29.6
29.6
29.6
6.8
3.1
2.2
5.5
96
20
23
19
HHIS-WC-SE-B25-00, 2008.12 Designed by Design Korea