Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

FOOTING

Column Size = 400 mm 1. Area of Footing 4. Depth Required for One Way Shear 6. Development Length
Pu = 950.306 KN
Mu = 6.113 KN-m A = 2.112 m² D = 405 mm ℓd = 490 mm 496.8
B = 2.5 m C+D = 805 mm 0.06ØbFy = 496.8 mm
Concrete Properties B Used = 2.5 m Vu = 1048.838 KN Use ℓd = 496.8mm
e = 0.00643 m ØVc = 1695.667 Kn ℓAvail = 975 mm
γ Concrete = 23.6 KN/m³ H Rec = 0.6 m SAFE FOR PUNCHING SHEAR!!
f'c = 27.6 MPa H used = 0.5 m Use 490mm Development length
qnet = 423.8 kPa 5. Steel Reinforcement without hook
Steel Properties
Use 0.5m x 2.5m x 2.5m x = 1.05 m
fy = 414 MPa qu₂ = 152.4244 KPa
Mu₁ = 211.8707 KN-m 211.8707
Soil Properties 2. Bearing Pressure for Strength Design Mu₂ = 209.5425 KN-m
Use Mu = 211.87KN-m
γ Soil = 18 KN/m³ qumax = 154.3954 kPa R = 0.604 Mpa
qa = 450 Kpa qumin = 149.7025 kPa ρ = 0.001478 0.0034
ρmin = 0.003382
Foundation Properties 3. Depth Base Requirement for Two way Use ρ = 0.0034
d = 460 mm
Conc cover = 75 mm d = 395 mm As = 3910 mm²
Temp. ba Ø = 20 mm x = 0.655 m N = 13 pcs
Main bar Ø = 20 mm B-x = 1.845 m Ab = 314.16 mm²
df = 1.3 m qu1 = 153.166 Kpa S = 233.9235 mm
Ø = 0.75 Vu = 251.8158 KN S = 230 mm
ʎ = 1 ØVc = 661.4573 KN
SAFE FOR BEAM SHEAR! Use 13 - 20mm Ø main bar both ways
spaced at 230 mm O.C.

Use 2.5m x 2.5m x 0.5m square footing


with 13 - 20mm Ø main bar both ways spaced at 230 mm O. C.