RCS-917 Reactor Protection

Reactor Protection
The RCS­917 relay is used for the main and back­up protection and
mechanical protection of shunt reactors. It is fully compatible with IEC
61850 communication.

Categories

Protection, Automation & Control

- Protection & Control

· Transmission Line Protection


· Busbar Protection

· Transformer Protection

· Reactor Protection
Send Inquiry Now
· Circuit Breaker Protection
· Generator Protection

Functions Features Download · Feeder Protection

· Motor Protection

Percentage restraint differential protection. (87R) Mechanical protection. · Capacitor Protection

· Arc Protection
Unrestrained instantaneous differential protection. CT circuit failure supervision. (VTS)
· Transfer & Synchronization
(87UR)
VT circuit failure supervision. (CTS) - Automation
DPFC (Deviation Power Frequency Variation
Voltage and current drift auto adjustment. - Digital Substation
Component) current differential protection.
(7/87DR) Self diagnostic. - Energy Management

- Power Stability Control


Zero sequence current differential protection. Fault and disturbance recorder.
- Measurement
(87NR)
GPS clock synchronization.
- Recording
Inter­turn fault protection. (32G/21G)
64 pieces of tripping reports - Accessories
Two­stage definite time and one­stage inverse - Software Kit
64 pieces of alarm reports
time overcurrent protection. (50P/51P)
64 pieces of binary input status change reports. HVDC & FACTS
Two­stage overcurrent protection for grounded
reactor. (50G /51G) Rear communication ports: Ethernet (Optional)
Renewable & BESS
with IEC 61850, 2 RS­485 with IEC 60870­5­103,
Two­stage zero sequence overcurrent protection.
1 RS­485 for clock synchronization, 1 RS­232 for
(50N/51N)
communication to printer.
Related Links
Thermal overload protection. (49)
Front communication port: 1 RS­232 for testing AC Transmission
Thermal overload protection for grounded reactor. and setting.
Thermal Power Plant
(49G)
AC Distribution

Hydro Power Plant

Nuclear Power Plant

Pumped Storage Power Plant

DC Transmission

Solar/Wind Farms

Who Are We What Are We Doing Whom Do We Serve Follow Us


·Our News ·Protection, Automation & Control ·Power Grids
·Our Culture ·FACTS & HVDC ·Power Plants
·Contact Us ·Renewable Energy Generation ·Industrials    
·Quality Control

Copyright NR Electric Co., Ltd. 2001­2016. All Rights Reserved.

You might also like