Professional Documents
Culture Documents
Product Data Sheet: Domae MCB - Miniature Circuit-Breaker - 1P - 6A - C Curve - 6000A
Product Data Sheet: Domae MCB - Miniature Circuit-Breaker - 1P - 6A - C Curve - 6000A
Product Data Sheet: Domae MCB - Miniature Circuit-Breaker - 1P - 6A - C Curve - 6000A
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Main
Range Domae
Product or component type Miniature circuit-breaker
Device short name Domae MCB
Device application Distribution
Poles description 1P
Number of protected poles 1
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
[In] rated current 6 A
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Network type AC
Trip unit technology Thermal-magnetic
Curve code C
Breaking capacity Icn 6000 A
Complementary
Network frequency 50/60 Hz
[Ue] rated operational voltage 230 V AC 50/60 Hz
Magnetic tripping limit 5...10 x In
[Ics] rated service breaking capacity 6000 KA 100 % x Icn conforming to EN/IEC 60898-1
Contact position indicator Yes
Control type Toggle
Local signalling Fault trip
Mounting mode Clip-on
Mounting support DIN rail
Comb busbar and distribution block compatibility YES
9 mm pitches 2
Height 81 Mm
Width 18 Mm
Depth 78.5 Mm
Net weight 0.095 Kg
Colour White
Mechanical durability 20000 Cycles
Connections - terminals Tunnel type terminals (top or bottom) - 1...25 mm² - rigid
Tunnel type terminals (top or bottom) - 1...16 mm² - flexible
Wire stripping length 14 Mm for top or bottom connection
Tightening torque 2 N.M top or bottom
Earth-leakage protection Without
Packing Units
Package 1 Weight 0.096 Kg
Package 1 Height 0.750 Dm
Package 1 width 0.180 Dm
Package 1 Length 0.850 Dm
Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation
REACh Declaration
REACh free of SVHC Yes
EU RoHS Directive
Compliant EU RoHS Declaration
Toxic heavy metal free Yes
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS Declaration
Environmental Disclosure
Product Environmental Profile
WEEE The product must be disposed on European Union markets following speci-
fic waste collection and never end up in rubbish bins
2
BCG0524
AUTOMATIC BATTERY CHARGER, SWITCHING BCG SERIES, FOR SEALED AND NOT
SEALED LEAD-ACID BATTERIES, 1 CHARGING LEVEL. 24VDC OUTPUT, 5A
Automatic battery
Product designation
chargers
Product type designation BCG
Single phase
automatic battery
charger 1
Type charging level for
sealed and non-
sealed lead-acid
batteries
Power supply
Rated voltage Us
min VAC 110
Max VAC 240 ±10%
Operational frequency
min Hz 50 ±10%
max Hz 60 ±10%
Power consumption
Max VA 364
Max W 158
Internal fuse A 6.3
Charging cycle
Reference standards IEC62368-1
non-sealed and
Battery type sealed lead-acid
batteries
Battery voltage VDC 24
in pos. V1:27.6;
Charging voltage (Uc)
V2:27.0
Boost % Uc +4.4
Charging current (Ic) 5
Charging current adjustment % Ic 20 to 100
Main supply fuse;
charging
inhibition due to:
1. Short circuit at
battery terminals;
Protections
2. Reverse
battery polarity; 3.
Low voltage at
battery poles; 4.
Output overload.
Indications
LED indicator for operating status Yes
LED reverse battery polarity Yes
Alarm output circuit
Output type 1 relay
The characteristics described in this document are subject to updates or modifications at any time. The descriptions, technical and
BCG0524 1/3
functional information, illustrations and instructions in this brochure are purely illustrative, and are consequently not contractually binding
BCG0524
AUTOMATIC BATTERY CHARGER, SWITCHING BCG SERIES, FOR SEALED AND NOT
SEALED LEAD-ACID BATTERIES, 1 CHARGING LEVEL. 24VDC OUTPUT, 5A
Wiring diagrams
The characteristics described in this document are subject to updates or modifications at any time. The descriptions, technical and
BCG0524 2/3
functional information, illustrations and instructions in this brochure are purely illustrative, and are consequently not contractually binding
BCG0524
AUTOMATIC BATTERY CHARGER, SWITCHING BCG SERIES, FOR SEALED AND NOT
SEALED LEAD-ACID BATTERIES, 1 CHARGING LEVEL. 24VDC OUTPUT, 5A
The characteristics described in this document are subject to updates or modifications at any time. The descriptions, technical and
BCG0524 3/3
functional information, illustrations and instructions in this brochure are purely illustrative, and are consequently not contractually binding
Product data sheet LV847130
Characteristics Circuit breaker Masterpact MTZ1 10H1, 1000
A, 3P fixed, without Micrologic
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Main
Range Masterpact
Product name Masterpact MTZ1
Device short name MTZ1 10 H1
Product or component type Circuit breaker
Device application Protection
Poles description 3P
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
Network type AC
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Network frequency 50/60 Hz
Breaking capacity code H1
Suitability for isolation Yes conforming to IEC 60947-2
Utilisation category Category B
Complementary
Control type Push-button
Mounting mode Fixed
Mounting support Rails
Base plate
[In] rated current 1000 A at 40 °C
[Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 12 KV conforming to IEC 60947-2
[Icm] rated short-circuit making capacity 88 KA 220/415 V AC at 50/60 Hz
88 KA 440 V AC at 50/60 Hz
88 KA 500/525 V AC at 50/60 Hz
88 KA 660/690 V AC at 50/60 Hz
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
Circuit breaker CT rating 630 A
400 A
800 A
1000 A
Breaking capacity 42 KA Icu at 220/415 V AC 50/60 Hz conforming to IEC 60947-2
42 KA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
42 KA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
42 KA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity 42 KA at 220/415 V AC 50/60 Hz conforming to IEC 60947-2
42 KA at 440 V AC 50/60 Hz conforming to IEC 60947-2
42 KA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
42 KA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 12500 Cycles with periodic preventive maintenance conforming to IEC 60947-2
Environment
Standards IEC 60364-8-1
IEC 60947-2
Product certifications LCIE
ASEFA
Pollution degree 3 conforming to IEC 60947-1
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -40…85 °C
Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation
REACh Declaration
EU RoHS Directive
Compliant EU RoHS Declaration
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS Declaration
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End Of Life Information
2
Product data sheet METSECT5DB100
Characteristics current transformer tropicalised 1000 5 double
output for bars 38x127
Main
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Range PowerLogic
Product name CT
Product or component type Current transformer
Secondary current 5 A
Accuracy class Class 0.5 at 6 VA
Class 1 at 10 VA
[In] rated current 1000 A
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Complementary
Current transformer type Tropicalised for busbar
Current transformer ratio 1000/5
[Ith] conventional free air thermal current 60 KA
Dynamic withstand current 2.5 Ith
Maximum safety factor 5
[Ue] rated operational voltage < 720 V AC 50/60 Hz
[Ui] rated insulation voltage 3 KV
Mounting mode Insulated locking screw
Mounting support Busbar
Width 38 Mm inner:
99 Mm outside:
Height 127 Mm inner:
160 Mm outside:
Depth 40 Mm frame:
78.4 Mm total:
Net weight 0.682 Kg
[Uimp] rated impulse withstand voltage 3 KV
Electrical insulation class Class B
Opening of bars 127 x 38
Sealing With
Environment
Standards VDE 0414
IEC 61869-2
Product certifications CE
IP degree of protection IP20
Relative humidity 0…95 %
Ambient air temperature for operation -25…60 °C
Offer Sustainability
EU RoHS Directive
Compliant EU RoHS Declaration
China RoHS Regulation
China RoHS Declaration
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End Of Life Information
WEEE The product must be disposed on European Union markets following speci-
fic waste collection and never end up in rubbish bins
2
InteliATS NT
Description
The InteliATSNT controllers are designed
to monitor the incoming AC mains
supply (1 or 3 phases) for under voltage,
over voltage, under frequency, over
frequency and voltage unbalance. In the
case of any mains supply disproportion
it will send a remote start command to
the generating set and make change
over for both generator and mains
contactors. The gen-set requires a
remote start type control unit (e.g. the
ComAp InteliLiteNT MRS 10 controller).
Available models
STD PWR
AUTOMATIC TRANSFER AUTOMATIC TRANSFER
SWITCH CONTROLLER SWITCH CONTROLLER
WITH POWER MEASURING
Order codes
Product Order code Product Order code
InteliATSNT
Schematic diagram
or
-USB
IL-NT S
+24V or
5
S232-48
IL-NT R
S232
IL-NT R
or
PRS
PLY IL-NT G
R SUP B
ALA
POWE VDC
8 to 36 ION IB-Lite
- UNICAT LE
RM
+ COMM MODU
STO
PLUG-IN
UTS
Y OUTP
P
)
BINAR OLLECTOR
C
(OPEN
TS STD
Y INPU 1×
BINAR 4× PWR
3× STD
SION
EXTEN MODULE 6x PWR
NT
TS
N
PLUG-I
InteliA MAINS
MEA
ATOR
GENER
VOL
SUR
MEA
TAG
IO8
EME
IL-NT B LER
NTROL
VOL
CUR
SUR
Y
ET CO BINAR
E
GEN-S
NT
TAG
INPUT
REN
EME
or Y
BINAR
T
OUTPU
E
T
NT
(OPEN TOR)
LL E C
O model
GEN
C
r PWR
MAIN
A Only fo
ERA
nnect: ),
SC
e to co D (SW
Possibl EM, IL-NT R T
TOR
B
.B. C
O D ERNE
Gen
T8 M
3ph
C ,
IL-NT AOU P
A /P LC, INT
Gen
SCA D
C.B
ONT
Rea
MAINS
3ph
. CO
3ph
Star
dy T
ROL
t/Sto
NTR
o Lo
p
OL
ad
LOAD
GAS ENGINE
DIESEL/
ER
NTROLL 10) )
ET CO NTMMRRSS10
GEN-S T
teliLite
(e.g. In
ATOR
GENER
Typical application
Description:
d
to loa
Ready
InteliA 10
monitors mains supply for under voltage, ENGINE
InteliLit
eNT MRS
ROOM
over voltage, under frequency, over GEN-S
ET
Scope of supply:
1× InteliATSNT STD
1× arbitrary gen-set controller (e.g. InteliLiteNT MRS 10) or key start box
InteliATSNT
Functions chart
Analog inputs – – 3
Magnetic pick-up – –
AMF function –
Input configuration
Output configuration
Current measurement – 3 ph 3 ph
Generator protections –
History file – –
Engine hours –
Internet support with Web server with IB-Lite with IB-Lite with IB-Lite
Internet support over GPRS with IL-NT GPRS with IL-NT GPRS with IL-NT GPRS
Modem interface O O O
Modbus interface – O O
Remote display O O O
Active SMS/emails – O O
This project is equipped with two gen-sets and one incoming mains supply. The site uses the
ComAp InteliLiteNT AJP3200 controllers and the ComAp InteliATSNT, there are 2 × IL-NT AJP3200
remote display panels and an InteliATSNT PWR on the switchboard. The 2 gen-sets also have
2 × IL-NT AJP3200 panels fitted on them. The InteliATSNT has an IB-Lite fitted allow it to be
connected into MITIE’s local network via an Ethernet connection, and provides the facility to
monitor and test the system via PC monitoring and control software.
ComAp a.s.
Czech Republic
Phone: + 420 246 012 111
Fax: + 420 266 316 647
E-mail: info@comap.cz
Internet: www.comap.cz
Customer satisfaction is our mission. We continuously develop our people to be the best to succeed in our mission.
© ComAp. Features and specification are subject to change without prior notice. 2015-01/CPLEIANT
Product data sheet RXM4AB1B7
Characteristics Miniature plug-in relay, 6 A, 4 CO, 24 V AC
Main
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Range of product Harmony Relay
Series name Miniature
Product or component type Plug-in relay
Device short name RXM
Contacts type and composition 4 C/O
[Uc] control circuit voltage 24 V AC 50/60 Hz
[Ithe] conventional enclosed thermal current 6 A at -40…55 °C
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
Status LED Without
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Control type Lockable test button
Utilisation coefficient 20 %
Complementary
Shape of pin Flat
[Ui] rated insulation voltage 250 V conforming to IEC
300 V conforming to CSA
300 V conforming to UL
[Uimp] rated impulse withstand voltage 2.5 KV during 1.2/50 µs
Contacts material AgNi
[Ie] rated operational current 3 A at 28 V (DC) NC conforming to IEC
3 A at 250 V (AC) NC conforming to IEC
6 A at 28 V (DC) NO conforming to IEC
6 A at 250 V (AC) NO conforming to IEC
6 A at 277 V (AC) conforming to UL
8 A at 30 V (DC) conforming to UL
Maximum switching voltage 250 V conforming to IEC
Load current 6 A at 250 V AC
6 A at 28 V DC
Maximum switching capacity 1500 VA/168 W
Minimum switching capacity 170 mW at 10 mA, 17 V
Operating rate <= 1200 cycles/hour under load
<= 18000 cycles/hour no-load
Mechanical durability 10000000 Cycles
Electrical durability 100000 Cycles for resistive load
Average coil consumption in VA 1.2 at 60 Hz
Average consumption 1.2 VA at 60 Hz
Drop-out voltage threshold >= 0.15 Uc
Operating time 20 ms
Reset time 20 Ms
Average resistance 180 Ohm at 20 °C +/- 15 %
Environment
Dielectric strength 1300 V AC between contacts with micro disconnection
2000 V AC between coil and contact
2000 V AC between poles
Product certifications CSA
Lloyd's
CE
UL
GOST
Standards CSA C22.2 No 14
UL 508
EN/IEC 61810-1
Ambient air temperature for storage -40…85 °C
Ambient air temperature for operation -40…55 °C
Vibration resistance 3 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles in operation
5 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles not operating
IP degree of protection IP40 conforming to EN/IEC 60529
Shock resistance 10 gn for in operation
30 gn for not operating
Pollution degree 2
Packing Units
Package 1 Weight 0.036 Kg
Package 1 Height 0.410 Dm
Package 1 width 0.210 Dm
Package 1 Length 0.280 Dm
Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation
REACh Declaration
REACh free of SVHC Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Decla-
ration
Toxic heavy metal free Yes
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS Declaration
Environmental Disclosure
Product Environmental Profile
WEEE The product must be disposed on European Union markets following speci-
fic waste collection and never end up in rubbish bins
Contractual warranty
Warranty 18 months
2
Product data sheet RXM4AB2P7
Characteristics Miniature plug-in relay, 6 A, 4 CO, LED, 230 V
AC
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Main
Range of product Harmony Relay
Series name Miniature
Product or component type Plug-in relay
Device short name RXM
Contacts type and composition 4 C/O
[Uc] control circuit voltage 230 V AC 50/60 Hz
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
[Ithe] conventional enclosed thermal current 6 A at -40…55 °C
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Status LED With
Control type Lockable test button
Utilisation coefficient 20 %
Complementary
Shape of pin Flat
[Ui] rated insulation voltage 250 V conforming to IEC
300 V conforming to CSA
300 V conforming to UL
[Uimp] rated impulse withstand voltage 2.5 KV during 1.2/50 µs
Contacts material AgNi
[Ie] rated operational current 3 A at 28 V (DC) NC conforming to IEC
3 A at 250 V (AC) NC conforming to IEC
6 A at 28 V (DC) NO conforming to IEC
6 A at 250 V (AC) NO conforming to IEC
6 A at 277 V (AC) conforming to UL
8 A at 30 V (DC) conforming to UL
Maximum switching voltage 250 V conforming to IEC
Load current 6 A at 250 V AC
6 A at 28 V DC
Maximum switching capacity 1500 VA/168 W
Minimum switching capacity 170 mW at 10 mA, 17 V
Operating rate <= 1200 cycles/hour under load
<= 18000 cycles/hour no-load
Mechanical durability 10000000 Cycles
Electrical durability 100000 Cycles for resistive load
Average coil consumption in VA 1.2 at 60 Hz
Average consumption 1.2 VA at 60 Hz
Drop-out voltage threshold >= 0.15 Uc
Operating time 20 ms
Reset time 20 Ms
Environment
Dielectric strength 1300 V AC between contacts with micro disconnection
2000 V AC between coil and contact
2000 V AC between poles
Product certifications CE
CSA
GOST
UL
Lloyd's
Standards CSA C22.2 No 14
EN/IEC 61810-1
UL 508
Ambient air temperature for storage -40…85 °C
Ambient air temperature for operation -40…55 °C
Vibration resistance 3 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles in operation
5 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles not operating
IP degree of protection IP40 conforming to EN/IEC 60529
Shock resistance 10 gn for in operation
30 gn for not operating
Pollution degree 2
Packing Units
Package 1 Weight 39.000 G
Package 1 Height 41.000 Mm
Package 1 width 28.000 Mm
Package 1 Length 21.000 Mm
Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation
REACh Declaration
REACh free of SVHC Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Decla-
ration
Toxic heavy metal free Yes
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS Declaration
Environmental Disclosure
Product Environmental Profile
WEEE The product must be disposed on European Union markets following speci-
fic waste collection and never end up in rubbish bins
Contractual warranty
Warranty 18 months