Professional Documents
Culture Documents
Ultima X Series Gas Monitors: Company Confidential
Ultima X Series Gas Monitors: Company Confidential
Category I MSA Instrument Division Product Group 0700 ATO Order Form
6 Gas Sampling
2 Gas Type 0 = Diffusion
11 Carbon Monoxide 0-100 PPM
12 Carbon Monoxide 0-500 PPM
7 LED / Relays Options
13 Oxygen 0- 10% 0 = No LED’s and No Relays
14 Oxygen 0-25%
1 = LED’s and No Relays
15 Hydrogen Sulfide 0-10 PPM
16 Hydrogen Sulfide 0-50 PPM 2 = Relays and No LED’s
17 Hydrogen Sulfide 0-100 PPM 3 = LED’s and Relays
# 18 Chlorine 0-5 PPM
8 Language
19 Sulfur Dioxide 0-25 PPM
20 Nitric Oxide 0-100 PPM 0 = English
# 21 Nitrogen Dioxide 0-10 PPM
22 Hydrogen Cyanide 0-50 PPM 9 Power Supply
# 23 Hydrogen Chloride 0-50 PPM 0 = None
# 24 Chlorine Dioxide 0-3 PPM
31 Combustible gas 0-100% LEL - Natural Gas & H2 10 Gas Type – Second Sensor
32 Combustible gas 0-100% LEL – Petroleum Vapors 0 = None
33 Combustible gas 0-100% LEL – Solvents
38 IR combustible 0-100% LEL – Methane 11 Gas Type – Third Sensor
39 IR combustible 0-100% LEL – Non-Methane 0 = None
41 Phosphine 0-2 PPM
42 Arsine 0-2 PPM 12 Calibration Options
43 Silane 0-25 PPM
0 = None
44 Germane 0-3 PPM
1 = Calibrator (P/N 809997)
45 Diborane 0-50 PPM
2 = Controller (P/N 809086)
# 46 Bromine 0-5 PPM
3 = Calibrator and Controller
# 47 Flourine 0-10 PPM
# 48 Ammonia 0–50 PPM Note: Calibrator not Intrinsically Safe in Europe.
49 Hydrogen 0-1000 PPM 13 Installation Hardware
# ^ 50 Ethylene Oxide 0-10 PPM 0 = None
1 = Strap assembly (XE only)
3 Sensor Output
B Milliamp Output 4-20, 2 wire toxic 3 = NEMA 4X installation kit (XA only)
And oxygen (without LED’s or relays)
14 Custom Features
E Milliamp Output 4-20, 3 wire toxic
and oxygen sensors (with LED’s and/or relays) 0 = None
AND all combustible sensors C = Custom material
T = Tagging – Aluminum tagging
4 Enclosure Type - Stainless Steel tagging
0 = GP Enclosure
Key: + Explosion-proof single condulet versions are approved for:
+ * 1 = XP Enclosure – cUL approved: NPT cUL Class I, Div. 1, Groups B, C, D
threads (CSA combustible performance pending)
* Explosion proof dual condulet versions are approved for:
cUL Class I, Div. 1, Groups A, B, C, D
(CSA combustible performance pending)
# Not available with explosion-proof approvals
^ 10 ppm SO2 cal gas = 4 ppm EtO
^ 10 ppm SO2 cal gas = 4 ppm Eto
COMPANY CONFIDENTIAL
Category I MSA Instrument Division Product Group 0700 ATO Order Form
Accessories
809997 Calibrator
809086 Controller
697281 Strap Assembly (XE only)
10041893 NEMA 4X Installation kit (XA only)
10041866 Flow cap – Ultima XE
10028904 Sensorgard – Ultima XE/XA
10041265 Sensorgard – Ultima XIR
10042600 Flow Cap – Ultima XIR
10041533 Calibration Cap – Ultima XIR
10036101 Ultima X Series Manual (printed version)
10042446 Ultima X Series product CD
10042803 Ultima X Controller Upgrade Kit
For sensing multiple gases always calibrate for the least sensitive
gas or vapor expected to be measured (highest response factor
within a category).