Neptuno Pumps 60 HZ VTP Perfomance Curves

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 84

Engineered Pump Catalog

60 Hz Perfomance Curves
ENGINEERED PUMP CATALOG
60 Hz Perfomance Curves
1
Neptuno Pumps®
Engineered Pump Catalog 60 Hz Perfomance Curves
Copyright © Neptuno Fluid Technology Ltd. All rights reserved.
Neptuno Pumps® is a registered trademark of Neptuno Fluid Technology Ltd.
026016 Edition
www.neptunopumps.com

2
Index

Vertical Turbine Pumps (VTP) .................................................................................................... 7

Applications....................................................................................................................................... 10

Main Components & Materials.......................................................................................................... 10

Range Chart - 60 Hz - 1 Stage.......................................................................................................... 11

Available Models............................................................................................................................... 11

Diagram............................................................................................................................................. 12

Main Dimensions............................................................................................................................... 13

AS SIMPLE AS 1-2-3
Find the right Vertical Turbine Pump (VTP) for your
application using the Neptuno Pumps® VTPSelector™.
Simply select your system design point, fluid
characteristics and NPSH ratings and the VTPSelector™
will create a dynamic pump curve. From there you can
adjust operating speeds, view/save electronic curves
and data sheet reports in a PDF format, generate system
curves, simulate multiple pumps/speeds, request quotes
and much more.

w w w . v t p s e l e c t o r. c o m
Pump Perfomance Curves 60 Hz

ABOUT US TESTING
NEPTUNO PUMPS is a world-class manufacturer
®
ISO 9906 certified state-of-the-art Testing Facility, in
of centrifugal pumps for industrial and heavy-duty accordance with Hydraulic Institute Standards and ISO
applications, delivering a comprehensive liof innovative 13709/API 610.
products and engineered pumping solutions to satisfy
and exceed your most demanding needs with the APPLICATIONS
highest quality and lowest lead-times in the market.
• Primary Water Supply – Fresh water or Sea water
TECHNOLOGY • Mining Processes: Cooling Water, Thickener
Overflow, Reclaim Water, MiSeepage, Well Pumps-
NEPTUNO PUMPS® counts with a highly skilled team
Process, Water Supply, MiDe-Watering, Electrolyte,
of engineers and well-trained personnel; state-of-the-
Pressure Boosting and Transfer
art computer assisted design softwares and advanced
manufacturing technologies complemented with • Solvent Extraction/Electro-Winning (SX/EW):
rigorous quality control systems that guarantee high Raffinate, Pregnate Leach Solution (PLS), Heap
quality products and services with its emphasis on total Leach, Dump Leach, Acid Water Pressure Boosting
customer satisfaction. and Transfer
• Dewatering – Sump, Deep Well, Ponds
RESEARCH & DEVELOPMENT
• Tailings – Post Processed Solutions
NEPTUNO PUMPS® is continually working with
business partners and most prestigious universities • Seepage Water – Sump or Can/Booster
and institutions in the areas of mechanical, hydraulic,
• Oil & Gas Production – Onshore, Offshore and
aerospace engineering and material science. Our
Pipeline
active in-house R&D Department is permanently
doing research for new designs and developing new • Marine
technologies always focusing on maximizing efficiency • Pulp and Paper
and delivering innovative pumping solutions, to keep
your business going strong. • Municipal Water & Wastewater
• Agriculture - Irrigation
QUALITY, ENVIRONMENT, SAFETY & HEALTH
PROGRAM
The principals of Quality Management System (QMS)
are the foundation of our business. That is why all our
Design and Manufacturing Processes are certified
under:
• ISO 9001: 2008
• ISO 9906: 1999
• ISO 14001: 2004
• OHSAS 18001: 2007
And conforms or meets most recognized specifications,
including:
• ANSI/HI
• ANSI/AWWA E101
• ISO 13709/API 610 Latest Edition.

5
Vertical Turbine Pumps (VTP)

7
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


Versatility is oof the main characteristics of NEPTUNO PUMPS® VTP: flanged bowl construction, single
or multiple stage design, depending on your total head requirements, for continuous service. Heavy duty
design for long term operation in industrial applications.

VERTICAL PUMPS MODELS SERVICES

• VERTICAL Turbine Pumps (VTP) • Primary Water Supply – Fresh water or Sea
water
• VERTICAL CAN TYPE (VC)
• Mining Processes: Cooling Water, Thickener
Overflow, Reclaim Water, MiSeepage,
OPERATING PARAMETERS
Well Pumps-Process, Water Supply, MiDe-
• Capacities up to 40,000 gpm (7,500 m3/h) Watering, Electrolyte, Pressure Boosting and
Transfer
• Head up to 1,200 Feet (400 m)
• Solvent Extraction/Electro-Winning (SX/EW):
• Power through 2000 hp (1500 kW)
Raffinate, Pregnate Leach Solution (PLS),
• Pressures up to 590 psi (4,067 kPa) Heap Leach, Acid Water Pressure Boosting
• Frequency 50/60 Hz and Transfer

• Temperatures to 400 °F (200°C) • Dewatering – Sump, Deep Well, Ponds

• Bowls sizes from 8” to 40” • Tailings – Post Processed Solutions


• Seepage Water – Sump or Can/Booster
DESIGN FEATURES • Oil & Gas Production – Onshore, Offshore
and Pipeline
• NEPTUNO PUMPS® high-efficiency design
• Marine
• High-quality investment cast impellers and
• Pulp and Paper
bowls
• Municipal Water & Wastewater
• Maximum versatility and reliability
• Agriculture - Irrigation
• Low NPSH first stage construction
• No priming required
• Thrust balanced impellers available
• Product lube or enclosed lineshaft
• Minimum space requirement
• Special material selection for standard or
abrasive/corrosive service
• Packing or mechanical seal
• Independent axial-thrust bearing assembly
• Multiple discharge configurations and sizes

9
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


Applications

Heavy Medium Low


Duty

High Medium Low


Capacity

High Medium Low


Head

Clean Process Slurry


Fluid

High Medium Low


Flexibility

Vertical Turbine Pumps (VTP)


Main Components & Materials

Material

Components Cast Iron Carbon Steel Brass Stainless Steel Duplex Polymer

Suction Bell

Bowl

Impeller

Wear Rings

Shaft

Discharge Head

Stuffing Box / Mechanical Seal

10
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


Available Models

VTP 30 VTP 50 VTP 60M VTP 80C


VTP 100 VTP 110 VTP 130 VTP 135X
VTP 170 VTP 170M VTP 180 VTP 180M
VTP 250 VTP 290 VTP 300 VTP 300MH
VTP 325 VTP 325X VTP 360 VTP 400M
VTP 450 VTP 500 VTP 500M VTP 500X
VTP 650 VTP 700 VTP 750 VTP 750M
VTP 800 VTP 850 VTP 850M VTP 850X
VTP 850XB VTP 1000 VTP 1000X VTP 1250
VTP 1300 VTP 1350 VTP 1500 VTP 1500L
VTP 1500LH VTP 1500KM VTP 1800M VTP 1800X
VTP 2200 VTP 2200M VTP 3000 VTP 3400
VTP 3400M VTP 6500

Vertical Turbine Pumps (VTP)


Range Chart - 60 Hz - 1 Stage

11
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


Diagram

VERTICAL MOTOR
SOLID SHAFT

STAND MOTOR WITH


BEARING HOUSING

DISCHARGE HEAD

A
CENTER LINE
DISCHARGE HEAD
DATUM 0
G

OP
MAXIMUM LIQUID LEVEL
BF
FLANGED COLUMN

BW

BD MINIMUM SUBMERGENCE

BOWL ASSEMBLY

S
L
Lbowl

Lbell

Lstrainer

C
Hmin FD

12
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


Main Dimensions

Discharge Head
Pump’s Principal Dimensions Bowl Assembly Dimensions Principal
Dimensions
Ls-
Column S H BW L [in] Lbowl [in]
Pump FD BD OP C Lbell trai- G BF A
Diame- min min min (1st Each add
Model [in] [in] [in] [in] [in] ner [in] [in] [in]
ters [in] [in] [in] [in] Stage) Stage
[in]
30 4 7.8 7.8 9.4 9.1 6.3 2.3 5.8 6.3 2.4 3.9 3.9 8.5 18.9 39.4

50 4 7.1 9.4 11.3 12.8 6.6 2.1 5.3 10.5 7.4 3.1 4.4 8.5 18.9 51.2

60M 4 7.1 7.1 8.5 10.5 6.7 2.1 5.3 7.1 3.1 3.9 4.5 8.5 18.9 51.2

80C 4 9.6 9.6 11.6 9.9 13.1 2.9 7.2 10.4 7.3 3.1 10.2 8.5 18.9 51.2

100 6 9.5 10 11.5 12.8 8 2.8 7.1 13.3 8.4 4.9 5.2 8.5 18.9 51.2

110 4 9.3 9.8 11.3 13.3 7.5 2.8 6.9 8.9 6.5 2.4 4.7 8.5 18.9 51.2

130 4 7.8 8.3 9.5 15.3 7.1 2.3 5.8 8.9 6.5 2.4 4.7 8.5 18.9 51.2

135X 4 11.6 11.6 13.3 14.3 8.2 3.5 8.7 10.0 6.5 3.5 4.7 8.5 18.9 51.2

170 6 9.5 10 11.5 16.4 8 2.8 7.1 13.3 8.4 4.9 5.2 8.5 18.9 51.2

170M 6 9.5 10 11.5 19.7 8 2.8 7.1 13.3 8.4 4.9 5.2 8.5 18.9 51.2

180 8 9.5 12.2 14 16.9 8 2.8 7.1 14.1 9.2 4.9 5.2 9.8 25.9 51.2

180M 6 14 14.8 17.1 16.4 14.9 4.2 10.5 17.9 10 7.9 10.7 8.5 18.9 51.2

250 8 9.4 12.8 14.8 20.6 8.3 2.8 7.1 10.5 6.7 3.8 5.5 9.8 25.9 70.9

290 8 9.2 11.6 14.8 23.2 10.6 2.8 6.9 14.2 8.9 5.3 7.9 9.8 25.9 51.2

300 10 13.8 14 17.7 19.9 15 4.1 10.3 19 12.5 6.5 10.8 11.6 32.2 51.2

300MH 10 16.8 16.7 19.3 21.1 16.9 5.0 12.6 24.4 14.0 10.4 11.9 13.5 47.6 47.2

325 6 17.7 14.9 20.4 19.9 15.7 5.3 13.3 23 11 12 10.4 8.5 18.9 51.2

325X 8 17.5 19.3 21.9 22.2 17.1 5.3 13.1 14.3 8.5 5.8 11.8 9.8 23.6 51.2

360 8 9.5 12.8 14.8 26.3 8 2.8 7.1 14.1 9.2 4.9 5.2 9.8 25.9 51.2

400 8 13.8 21.3 24.4 16.7 15.9 4.1 10.4 17.7 10.4 7.3 11.8 9.8 25.9 51.2

450 10 17 17.5 20.1 23.2 16.3 5.1 12.7 22.4 13.6 8.9 11.2 11.6 32.2 51.2

500 10 13.8 14.2 17.7 25.8 13.9 4.1 10.3 20.8 13.8 7 9.7 11.6 32.2 51.2

500M 10 21.7 20.5 24.9 33.0 18.3 6.5 16.3 21.7 11.2 10.4 11.8 12.2 32.0 57.1

500X 10 20.5 20.5 23.5 23.9 16.6 6.1 15.4 18.5 11.3 7.2 10.4 11.6 32.2 57.1

650 12 20.4 17.5 20.1 27 20.8 6.1 15.3 28.5 16.5 12 14.6 13.4 38.3 57.1

700 12 24.2 24.2 27.8 28.3 19.7 7.3 18.2 28.5 17.7 10.8 12.5 13.4 38.3 57.1

750 14 19.9 27.7 31.9 28.7 19.7 6 14.9 28.7 17.5 11.2 13.8 15 42 57.1

750M 14 24.2 25.7 29.5 28.9 22.3 7.3 18.2 24.2 15.6 8.7 15 15 42 57.1

800 12 19.7 16.0 18.4 29.5 13.4 5.9 14.8 21.3 14.9 6.4 7.5 12.6 42.0 57.1

800M 14 18.5 18.5 21.3 31.0 13.4 5.6 13.9 23.6 11.8 11.8 7.9 15.0 39.4 57.1

850 14 17.5 18.7 21.6 31.6 15.1 5.3 13.1 29.3 18.6 10.6 9.8 15 42 57.1

850M 14 18.5 18.5 21.3 31.0 13.4 5.6 13.9 23.6 11.8 11.8 7.9 15.0 39.4 57.1

850X 14 18.5 18.5 21.3 31.0 13.4 5.6 13.9 23.6 11.8 11.8 7.9 15.0 39.4 57.1

850XB 16 24.2 24.2 27.8 28.3 19.8 7.3 18.1 28.5 17.7 10.8 12.5 13.4 38.3 57.1

1000 14 18 19.9 22.9 34.3 14.5 5.4 13.5 31.7 18.3 13.4 9.1 15 42 57.1

1000X 14 28.7 28.7 33.1 32.8 26.3 8.6 21.6 28.5 12.8 15.7 17.7 15.0 39.4 57.1

13
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


Main Dimensions (cont.)

Discharge Head
Pump’s Principal Dimensions Bowl Assembly Dimensions Principal
Dimensions
Ls-
Column S H BW L [in] Lbowl [in]
Pump FD BD OP C Lbell trai- G BF A
Diame- min min min (1st Each add
Model [in] [in] [in] [in] [in] ner [in] [in] [in]
ters [in] [in] [in] [in] Stage) Stage
[in]
1250 12 19 22.4 25.8 38.1 28 5.7 14.3 31 18 13 22.3 13.4 38.3 57.1

1300 16 17 25 28.8 41.7 14.2 5.1 12.8 28.7 15.6 13.1 9.1 16.5 48 63

1350 14 25.5 25.5 29.3 42.0 19.6 7.6 19.1 29.8 19.0 10.8 12.0 14.0 47.2 51.2

1500 16 20.2 25 28.8 41.2 16.4 6.1 15.1 27.3 17.9 9.4 10.3 16.5 48 70.9

1500KM 14 25.5 22.4 29.3 38.1 19.6 7.6 19.1 28.9 19.0 9.9 12.0 13.9 44.0 67.3

1500L 16 21.1 21.1 24.2 40.5 16.6 6.3 15.8 24.2 14.6 9.5 10.3 16.5 48 68.9

1500LH 16 21.1 21.1 24.2 40.5 16.6 6.3 15.8 24.2 14.6 9.5 10.3 16.5 48 68.9

1800M 16 22.8 22.8 27.6 43.3 14.7 6.9 17.1 28.0 16.1 11.8 7.9 16.5 51.2 68.9

1800X 16 22.4 25.2 29.0 45.0 22.5 6.7 16.9 27.0 16.7 10.3 15.7 16.5 51.2 68.9

2200 20 33.1 32.4 37.2 44.1 24.9 9.9 24.8 38.4 24 14.4 15 20.9 60 72.8

2200M 20 33.1 32.4 37.2 44.1 24.7 9.9 24.8 39 24.4 14.6 14.8 20.9 60 72.8

3000 20 36 37.1 42.7 49.9 23.4 10.8 27 48.9 28.9 20 12.6 25.2 72 78.7

3400 22 36.2 34.6 39.8 52.6 29.4 10.9 27.2 44.8 28.5 16.3 18.5 25.2 72 78.7

3400M 24 36.2 37.6 43.2 52.6 26.4 10.9 27.2 43.8 28.5 15.3 15.6 25.2 72 78.7

6500 26 39 43.3 49.8 65.5 33.6 11.7 29.2 48.2 28.8 19.4 21.9 27.6 78 98.4

Discharge Configurations
Multiple discharge configurations and sizes

14
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


3600 rpm
VTP 30
Curve #: 11063-140207-S1

Q [gpm]
0 25 50 75 100 125 150 175 200 225 250 275 300
55 180
152 mm
50 165
 
   
142 mm   150
45  

  135
40  
130 mm
  120
35  
 
105
30
H [m]

H [ft]
90
25
75
20
60

15
45

10
30

5 15

0 0

12
15

10
152 mm 12
8

142 mm
P [kW]

9
P [hp]

6
130 mm
6
4

2 3

0 0

9
24
NPSHr [m]

NPSHr [ft]

6
18

12
3
6

0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
15
Pump Perfomance Curves 60 Hz

VTP 50 Vertical Turbine Pumps (VTP)


3600 rpm
Curve #: 11001-110214-S1

Q [gpm]
0 40 80 120 160 200 240 280 320 360

179 mm 180

50 ˇ 60
168 mm 160
ˇ 63
ˇ 65
ˇ 66
140
155 mm
40

120
ˇ 66
ˇ 65
H [m]

ˇ 63 100

H [ft]
30
ˇ 60

80

20
60

40
10

20

0 0

179 mm
9 12

168 mm
7.5 10

6 155 mm 8
P [kW]

P [hp]

4.5 6

3 4

1.5 2

0 0

4.5 15
NPSHr [m]

NPSHr [ft]

3 10

1.5 5

0 0
0 10 20 30 40 50 60 70 80 90
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
16
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


3600 rpm
VTP 60M
Curve #: 11086-151123-S1

Q [gpm]
0 50 100 150 200 250 300 350 400
50

160
45
146,6 mm
140
40

137 mm  
35   120
 
 
127 mm
30 100
H [m]

H [ft]
25  
80
 
20
 
60
15  

40
10

20
5

0 0

8 10

8
6
146,6 mm
6
P [kW]

P [hp]

137 mm
4
127 mm 4

2
2

0 0

12 40
NPSHr [m]

30
NPSHr [ft]

8
20
4
10

0 0
0 10 20 30 40 50 60 70 80 90 100
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
17
Pump Perfomance Curves 60 Hz

VTP 80C Vertical Turbine Pumps (VTP)


3600 rpm
Curve #: 11055-130718-F1

Q [gpm]
0 70 140 210 280 350 420 490 560 630 700
60 195
164,5 mm
55 180

50 155 mm   165
 
45   150
145 mm  
 
135
40
120
35  
  105
H [m]

H [ft]
30  
  90
25
  75
20
60
15
45

10
30

5 15

0 0

20
25

16
164,5 mm 20

12 155 mm
P [kW]

15
P [hp]

145 mm

8
10

4 5

0 0

15
45
NPSHr [m]

NPSHr [ft]

10
30

5 15

0 0
0 15 30 45 60 75 90 105 120 135 150 165
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
18
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


1800 rpm
VTP 100
Curve #: 11002-070713-F1

Q [gpm]
0 80 160 240 320 400 480 560 640 720
55
16 188 mm
50
179 mm η 67
14 η 71 45
170 mm η 74
η 76
12 40

η 76
35
η 74
10
η 71
H [m]

30

H [ft]
η 67
8
25

6 20

15
4
10

2
5

0 0

6
188 mm
7.5
5 179 mm
6
170 mm
4
P [kW]

P [hp]

4.5
3

3
2

1 1.5

0 0

7.5 24
NPSHr [m]

NPSHr [ft]

5 16

2.5 8

0 0
0 15 30 45 60 75 90 105 120 135 150 165 180
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
19
Pump Perfomance Curves 60 Hz

VTP 110 Vertical Turbine Pumps (VTP)


3600 rpm
Curve #: 11003-071121-S1

Q [gpm]
0 100 200 300 400 500 600 700 800

210
60 193.7 mm η 70
η 73 η 75
η 76
185 mm 180
η 76
50 175 mm η 75
η 73
150
η 70
40
H [m]

120

H [ft]
30
90

20
60

10 30

0 0

45

30 193.7 mm 40

35
25 185 mm
30
175 mm
20
P [kW]

P [hp]

25

15 20

15
10
10
5
5

0 0

28

75
NPSHr [m]

NPSHr [ft]

21

14 50

7 25

0 0
0 20 40 60 80 100 120 140 160 180
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
20
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


3600 rpm
VTP 130
Curve #: 11004-081121-S1

Q [gpm]
0 100 200 300 400 500 600 700 800 900

40
120
148 mm
η 68
η 72
35 η 75
η 77
137 mm 100
η 77
30
η 75
123 mm η 72 80
25
H [m]

η 68

H [ft]
20 60

15
40

10

20
5

0 0

148 mm
18 24

15 137 mm 20

12 16
P [kW]

P [hp]

123 mm
9 12

6 8

3 4

0 0

24 75
NPSHr [m]

NPSHr [ft]

16 50

8 25

0 0
0 20 40 60 80 100 120 140 160 180 200
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
21
Pump Perfomance Curves 60 Hz

VTP 135X Vertical Turbine Pumps (VTP)


3600 rpm
Curve #: 11076-141114-S1

Q [gpm]
0 150 300 450 600 750 900 1050 1200
100
320

90 222 mm         280
 
80
202 mm  
240
70  
 
180 mm 200
60  
H [m]

 

H [ft]
50 160

40
120

30
80
20

40
10

0 0

72
90

60
222 mm 75

48
60
202 mm
P [kW]

P [hp]

36
45
180 mm
24 30

12 15

0 0

21
60
NPSHr [m]

NPSHr [ft]

14
40

7 20

0 0
0 30 60 90 120 150 180 210 240 270 300
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
22
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


3600 rpm
VTP 170
Curve #: 11005-080704-E1

Q [gpm]
0 150 300 450 600 750 900 1050 1200 1350 1500 1650

240
70 194 mm

210
181 mm η 72
60 η 76
η 79
η 81 180
168 mm
50
η 81
η 79 150
H [m]

η 76

H [ft]
40
η 72 120

30
90

20
60

10 30

0 0

45 194 mm
60

181 mm 50
36

40
P [kW]

P [hp]

168 mm
27
30
18
20

9
10

0 0

15
45
NPSHr [m]

NPSHr [ft]

10
30

5 15

0 0
0 40 80 120 160 200 240 280 320 360
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
23
Pump Perfomance Curves 60 Hz

VTP 170M Vertical Turbine Pumps (VTP)


3600 rpm
Curve #: 11006-090721-S1

Q [gpm]
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
220
189.6 mm
60 200
η 69
179 mm η 73
η 76 180
η 77
50 168 mm 160
η 77
η 76 140
40 η 73
H [m]

120

H [ft]
η 69

30 100

80

20
60

40
10
20

0 0

90
189.6 mm
60
75
50 179 mm
60
40 168 mm
P [kW]

P [hp]

45
30

30
20

10 15

0 0

120
NPSHr [m]

NPSHr [ft]

30
80

15
40

0 0
0 50 100 150 200 250 300 350 400 450 500
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
24
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


1800 rpm
VTP 180
Curve #: 11007-070717-E1

Q [gpm]
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300

27 88

24 80
226 mm

72
213 mm η 66
21 η 70
η 73 64
200 mm η 75
18
56
η 75
H [m]

H [ft]
15 48
η 73
η 70
12 40
η 66

32
9

24
6
16

3
8

0 0

18
226 mm
12
15
213 mm
10
12
200 mm
8
P [kW]

P [hp]

9
6

6
4

2 3

0 0
NPSHr [m]

NPSHr [ft]

6 20

3 10

0 0
0 30 60 90 120 150 180 210 240 270 300
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
25
Pump Perfomance Curves 60 Hz

VTP 180M Vertical Turbine Pumps (VTP)


1800 rpm
Curve #: 11008-081103-S1

Q [gpm]
0 150 300 450 600 750 900 1050 1200 1350

90
27
236.5 mm

24 80
226 mm η 69
η 74 η 77
216 mm η 80
21 70

η 80
18 60
η 77
η 74
H [m]

50

H [ft]
15 η 69

12 40

9 30

6 20

3 10

0 0

236.5 mm

15 226 mm 20

216 mm
12 16
P [kW]

P [hp]
9 12

6 8

3 4

0 0

36
NPSHr [m]

10
NPSHr [ft]

24
5
12

0 0
0 30 60 90 120 150 180 210 240 270 300 330
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
26
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


3600 rpm
VTP 250
Curve #: 11009-100625-E2

Q [gpm]
0 200 400 600 800 1000 1200 1400 1600 1800 2000
135

248 mm
η 74 400
120 η 79
η 83
η 86
233 mm
105 350

215 mm η 86
90 300
η 83

η 79
75 250
H [m]

H [ft]
η 74
60 200

45 150

30 100

15 50

0 0

120
150

100 248 mm
125

80 233 mm
100
P [kW]

P [hp]

60 215 mm
75

40 50

20 25

0 0

20
60
NPSHr [m]

NPSHr [ft]

15
40
10
20
5

0 0
0 40 80 120 160 200 240 280 320 360 400 440 480
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
27
Pump Perfomance Curves 60 Hz

VTP 290 Vertical Turbine Pumps (VTP)


3600 rpm
Curve #: 11010-081103-S1

Q [gpm]
0 300 600 900 1200 1500 1800 2100 2400

270
80 221 mm

215 mm η 70
η 74 240
70 η 78
200 mm η 81
210
60

180
η 81
50
η 78
H [m]

150

H [ft]
η 74
40
η 70 120

30
90

20
60

10 30

0 0

75 100
221 mm

60 215 mm 80

200 mm
P [kW]

P [hp]
45 60

30 40

15 20

0 0

150
40
NPSHr [m]

NPSHr [ft]

30 100

20
50
10

0 0
0 50 100 150 200 250 300 350 400 450 500 550 600
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
28
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


1800 rpm
VTP 300
Curve #: 11011-070713-F1

Q [gpm]
0 250 500 750 1000 1250 1500 1750 2000 2250 2500

40
285 mm 120
η 76
η 82
35 η 85
η 87 105
264 mm

30 90
242 mm η 87
η 85
25 75
η 82
H [m]

H [ft]
η 76
20 60

15 45

10 30

5 15

0 0

40 285 mm
50
35
264 mm
30 40

25
P [kW]

P [hp]

242 mm
30
20

15 20

10
10
5

0 0

40
NPSHr [m]

10
NPSHr [ft]

30

20
5
10

0 0
0 50 100 150 200 250 300 350 400 450 500 550 600
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
29
Pump Perfomance Curves 60 Hz

VTP 300MH Vertical Turbine Pumps (VTP)


1800 rpm
Curve #: 11090-160414-E1

Q [gpm]
0 400 800 1200 1600 2000 2400 2800
80

240
70
338,5 mm
210
   
60 318 mm  
 
  180
 
297 mm  
50  
150
H [m]

H [ft]
40
120

30
90

20
60

10 30

0 0

120
150
338,5 mm
100
125

80 318 mm
100
P [kW]

P [hp]

60 297 mm
75

40 50

20 25

0 0

12
NPSHr [m]

30
NPSHr [ft]

4 15

0 0
0 75 150 225 300 375 450 525 600
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
30
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


1800 rpm
VTP 325
Curve #: 11012-100701-E1

Q [gpm]
0 300 600 900 1200 1500 1800 2100 2400 2700 3000
45

135
40

303 mm η 64 120
35 η 67
η 70
η 72
105
277 mm
30
η 72
90
25 250 mm η 70
H [m]

H [ft]
75
η 67
20
η 64 60

15
45

10
30

5 15

0 0

75
60

60
303 mm
45
45
P [kW]

277 mm
P [hp]

30
30 250 mm

15
15

0 0

20
60
NPSHr [m]

NPSHr [ft]

15
45
10 30

5 15

0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
31
Pump Perfomance Curves 60 Hz

VTP 325X Vertical Turbine Pumps (VTP)


1200 rpm
Curve #: 11070-140513-F1

Q [gpm]
0 200 400 600 800 1000 1200 1400
50

150
45

420 mm 135
40
   
    120
35
385 mm
  105
30  
350 mm  
90
H [m]

H [ft]
 
25
75

20
60

15
45

10
30

5 15

0 0

35
45
420 mm
30 40

35
25
385 mm 30
20
P [kW]

P [hp]

25
350 mm
15 20

15
10
10
5
5

0 0

6
18
NPSHr [m]

NPSHr [ft]

4
12

2 6

0 0
0 50 100 150 200 250 300 350 400
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
32
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


1800 rpm
VTP 325X
Curve #: 11070-140513-F1

Q [gpm]
0 300 600 900 1200 1500 1800 2100 2400
100

300
90
420 mm
 
      270
80
385 mm
  240
70
 
  210
350 mm
60  
180
H [m]

H [ft]
50
150

40
120

30
90

20
60

10 30

0 0

120
150
420 mm
100
125

80
385 mm 100
P [kW]

P [hp]

60
350 mm 75

40 50

20 25

0 0

9
24
NPSHr [m]

NPSHr [ft]

6
18

12
3
6

0 0
0 75 150 225 300 375 450 525 600
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
33
Pump Perfomance Curves 60 Hz

VTP 360 Vertical Turbine Pumps (VTP)


3600 rpm
Curve #: 11013-080614-E1

Q [gpm]
0 300 600 900 1200 1500 1800 2100 2400 2700

360
105
235 mm
320

90 η 70
218 mm η 74
η 78 280
η 81
75
200 mm 240

η 81
η 78
H [m]

200

H [ft]
60
η 74
η 70
160
45

120

30
80

15
40

0 0

150
235 mm
100
120
218 mm
75
P [kW]

P [hp]
90
200 mm

50
60

25 30

0 0

60
NPSHr [m]

NPSHr [ft]

16
40
8
20

0 0
0 60 120 180 240 300 360 420 480 540 600 660
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
34
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


1200 rpm
VTP 400M
Curve #: 11074-140708-S1

Q [gpm]
0 300 600 900 1200 1500 1800 2100 2400
40

120
35 405 mm  
 
 
  105
382 mm
30
360mm   90

25  
  75
H [m]

H [ft]
 
20
60

15
45

10
30

5 15

0 0

40
50
35 405 mm

30 40
382 mm

25
360mm
P [kW]

P [hp]

30
20

15 20

10
10
5

0 0

9
24
NPSHr [m]

NPSHr [ft]

6
18

12
3
6

0 0
0 60 120 180 240 300 360 420 480 540 600
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
35
Pump Perfomance Curves 60 Hz

VTP 400M Vertical Turbine Pumps (VTP)


1800 rpm
Curve #: 11074-140708-S1

Q [gpm]
0 400 800 1200 1600 2000 2400 2800 3200
90

120
80 405 mm
 
 
  105
382 mm  
70

360 mm
  90
60
 

  75
50
H [m]

H [ft]
 

40 60

30 45

20 30

10 15

0 0

140
175
120 405 mm
150
100 382 mm
125
80
P [kW]

360 mm
P [hp]

100

60
75

40
50

20 25

0 0

18
48
NPSHr [m]

NPSHr [ft]

12
36

24
6
12

0 0
0 100 200 300 400 500 600 700 800
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
36
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


1800 rpm
VTP 450
Curve #: 11014-081103-S1

Q [gpm]
0 300 600 900 1200 1500 1800 2100 2400 2700 3000
110
32
283 mm
100

28 267 mm η 70 90
η 74
250 mm η 79
24 80
η 81

70
20 η 81
H [m]

60

H [ft]
η 79

16 η 74 50

12 40

30
8
20

4
10

0 0

60
40
283 mm
48
30 267 mm
P [kW]

P [hp]

250 mm 36

20
24

10
12

0 0

45
12
NPSHr [m]

NPSHr [ft]

30
8

4 15

0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
37
Pump Perfomance Curves 60 Hz

VTP 500 Vertical Turbine Pumps (VTP)


1800 rpm
Curve #: 11015-080802-E2

Q [gpm]
0 400 800 1200 1600 2000 2400 2800 3200 3600

135
40

120
35
289 mm
105
30
268 mm
η 66 90
25 η 72
245 mm η 76
H [m]

75

H [ft]
η 79
20
60

η 79
15
η 76 45
η 72
10 η 66 30

5 15

0 0

40
50
35
289 mm
30 40
268 mm
25
P [kW]

P [hp]
30
20 245 mm

15 20

10
10
5

0 0

12 40
NPSHr [m]

NPSHr [ft]

30
8
20
4
10

0 0
0 100 200 300 400 500 600 700 800 900
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
38
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


1200 rpm
VTP 500M
Curve #: 11085-151120-S1

Q [gpm]
0 350 700 1050 1400 1750 2100 2450
30

90
27
384,4 mm
   
  80
24  
360 mm
21 70
 
330 mm
 
18 60
 
H [m]

H [ft]
15 50
 

12 40

9 30

6 20

3 10

0 0

40
50
35
45
384,4 mm
30 40

360 mm 35
25
P [kW]

30
P [hp]

20 330 mm 25

15 20

15
10
10
5
5

0 0

9
24
NPSHr [m]

NPSHr [ft]

6
18

12
3
6

0 0
0 75 150 225 300 375 450 525 600
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
39
Pump Perfomance Curves 60 Hz

VTP 500M Vertical Turbine Pumps (VTP)


1800 rpm
Curve #: 11085-151120-S1

Q [gpm]
0 600 1200 1800 2400 3000 3600 4200
70
225

200
60
384,4 mm  
 
 
  175
50 360 mm

  150
330 mm
 
40  
125
H [m]

H [ft]
 
30 100

75
20

50

10
25

0 0

120
150
384,4 mm
100

360 mm 120
80

330 mm
P [kW]

90
P [hp]

60

60
40

20 30

0 0

15
45
NPSHr [m]

NPSHr [ft]

10
30

5 15

0 0
0 100 200 300 400 500 600 700 800 900 1000
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
40
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


1200 rpm
VTP 500X
Curve #: 11016-121116-E1

Q [gpm]
0 300 600 900 1200 1500 1800 2100
50

150
45
427 mm    
  135
 
40  
405 mm
120
35  
380 mm  
  105
30
 
  90
H [m]

H [ft]
25
75

20
60

15
45

10
30

5 15

0 0

50

427 mm 60

40
405 mm 50

30 380 mm 40
P [kW]

P [hp]

30
20

20

10
10

0 0

9
24
NPSHr [m]

NPSHr [ft]

6
18

12
3
6

0 0
0 50 100 150 200 250 300 350 400 450 500 550
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
41
Pump Perfomance Curves 60 Hz

VTP 500X Vertical Turbine Pumps (VTP)


1800 rpm
Curve #: 11016-121116-E1

Q [gpm]
0 500 1000 1500 2000 2500 3000 3500
110

100 300
427 mm    
 
   
90 405 mm 270

 
80 380 mm 240
 
 
70 210
 
 
60 180
H [m]

H [ft]
50 150

40 120

30 90

20 60

10 30

0 0

175

427 mm 210
150
180
125 405 mm
150
380 mm
100
P [kW]

P [hp]
120
75
90

50
60

25 30

0 0

15
45
NPSHr [m]

NPSHr [ft]

10
30

5 15

0 0
0 100 200 300 400 500 600 700 800
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
42
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


1800 rpm
VTP 650
Curve #: 11017-070713-E1

Q [gpm]
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000
225

367 mm
60 200

345 mm
175
η 68
50 η 72
320 mm η 75
η 77
150
η 77
40 η 75
η 72 125
H [m]

H [ft]
η 68

30 100

75
20

50

10
25

0 0

175

150 200
367 mm

125
160
345 mm
100
P [kW]

P [hp]

320 mm 120
75
80
50

40
25

0 0

45
12
NPSHr [m]

NPSHr [ft]

30
8

4 15

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
43
Pump Perfomance Curves 60 Hz

VTP 700 Vertical Turbine Pumps (VTP)


1200 rpm
Curve #: 11018-070713-E1

Q [gpm]
0 400 800 1200 1600 2000 2400 2800 3200

200
60
525 mm
55 η 68 180
η 71
η 74
50 490 mm η 76
160

45 η 76
450 mm 140
η 74
40
η 71
120
35
H [m]

H [ft]
30 100

25 80

20
60
15
40
10

20
5

0 0

150

100 525 mm

120
490 mm
75
P [kW]

P [hp]

90
450 mm
50
60

25 30

0 0

30
7.5
NPSHr [m]

NPSHr [ft]

20
5

10
2.5

0 0
0 100 200 300 400 500 600 700 800
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
44
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


1800 rpm
VTP 700
Curve #: 11018-070713-E1

Q [gpm]
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000

450
135
525 mm
η 68 400
120 η 71
η 74
490 mm η 76

105 350
η 76
450 mm
η 74 300
90
η 71
H [m]

250

H [ft]
75

60 200

45 150

30 100

15 50

0 0

400
500
350 525 mm

300 400
490 mm
250
P [kW]

300
P [hp]

200 450 mm

150 200

100
100
50

0 0

20
60
NPSHr [m]

NPSHr [ft]

15
45
10 30

5 15

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
45
Pump Perfomance Curves 60 Hz

VTP 750 Vertical Turbine Pumps (VTP)


1800 rpm
Curve #: 11019-090112-S1

Q [gpm]
0 600 1200 1800 2400 3000 3600 4200 4800 5400

150
45

317 mm
135
40
300 mm
120
35
η 73
283 mm η 77
η 79 105
30 η 80

η 80 90
H [m]

H [ft]
25 η 79
η 77 75
η 73
20
60

15
45

10
30

5 15

0 0

90 317 mm 120

75 300 mm 100

60 283 mm 80
P [kW]

P [hp]

45 60

30 40

15 20

0 0

18 60
NPSHr [m]

NPSHr [ft]

12 40

6 20

0 0
0 150 300 450 600 750 900 1050 1200
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
46
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


1200 rpm
VTP 750M
Curve #: 11020-081103-S1

Q [gpm]
0 500 1000 1500 2000 2500 3000 3500 4000 4500

160
45

464 mm
η 72 140
40
η 76
440 mm η 80
η 82
35 120
414 mm
η 82
30 η 80 100

η 76
H [m]

H [ft]
25
80

20
60
15

40
10

20
5

0 0

90 120
464 mm
75 100
440 mm
60 80
P [kW]

P [hp]

414 mm

45 60

30 40

15 20

0 0

9 30
NPSHr [m]

NPSHr [ft]

6 20

3 10

0 0
0 100 200 300 400 500 600 700 800 900 1000
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
47
Pump Perfomance Curves 60 Hz

VTP 750M Vertical Turbine Pumps (VTP)


1800 rpm
Curve #: 11020-081103-S1

Q [gpm]
0 700 1400 2100 2800 3500 4200 4900 5600 6300

360
105

320
464 mm
90 η 72
η 76
440 mm η 80 280
η 82
75 414 mm
240
η 82

η 80
H [m]

200

H [ft]
60
η 76
160
45

120

30
80

15
40

0 0

450

300 400
464 mm
350
250
440 mm 300
200
P [kW]

P [hp]

414 mm 250

150 200

150
100
100
50
50

0 0

75
21
NPSHr [m]

NPSHr [ft]

14 50

7 25

0 0
0 200 400 600 800 1000 1200 1400
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
48
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


1800 rpm
VTP 800
Curve #: 11043-120227-S1

Q [gpm]
0 800 1600 2400 3200 4000 4800 5600 6400
100

300
90
445 mm

  270
80 423 mm
 
 
400 mm   240
70

210
 
60
 
180
H [m]

H [ft]
50  

  150

40
120

30
90

20
60

10 30

0 0

245
320

210 280
445 mm

175 240
423 mm
200
140
P [kW]

P [hp]

400 mm
160
105
120
70
80

35 40

0 0

15
45
NPSHr [m]

NPSHr [ft]

10
30

5 15

0 0
0 150 300 450 600 750 900 1050 1200 1350 1500
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
49
Pump Perfomance Curves 60 Hz

VTP 850 Vertical Turbine Pumps (VTP)


1800 rpm
Curve #: 11021-070713-E1

Q [gpm]
0 800 1600 2400 3200 4000 4800 5600 6400

40 140

326 mm
35
120

300 mm
30
η 70 100
η 73
η 75
275 mm η 77
25 η 77 η 75 η 73
η 70
H [m]

80

H [ft]
20

60
15

40
10

20
5

0 0

150 200
326 mm
120 160
P [kW]

300 mm
P [hp]
90 120

275 mm
60 80

30 40

0 0

18 60
NPSHr [m]

NPSHr [ft]

45
12
30
6
15

0 0
0 150 300 450 600 750 900 1050 1200 1350 1500
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
50
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


1800 rpm
VTP 850M
Curve #: 11071-140616-S1

Q [gpm]
0 1000 2000 3000 4000 5000 6000 7000
60

350 mm 180
54

48 160
320 mm
 
  140
42  
 
285 mm
36 120

 
H [m]

H [ft]
30   100

 
24 80
 

18 60

12 40

6 20

0 0

140
175
120
350 mm 150
100
125
320 mm
80
P [kW]

P [hp]

100

60
285 mm 75

40 50

20 25

0 0

15
45
NPSHr [m]

NPSHr [ft]

10
30

5 15

0 0
0 200 400 600 800 1000 1200 1400 1600
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
51
Pump Perfomance Curves 60 Hz

VTP 850X Vertical Turbine Pumps (VTP)


1200 rpm
Curve #: 11022-101104-E1

Q [gpm]
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000
70
225
65 514 mm
 
60   200
482 mm  
 
55
  175
50 450 mm

  150
45
 
40
  125
H [m]

H [ft]
35  

 
30 100

25
75
20

15 50

10
25
5

0 0

140
180

120 160
514 mm
140
100
482 mm 120
80
P [kW]

P [hp]

450 mm 100

60 80

60
40
40
20
20

0 0

6
18
NPSHr [m]

NPSHr [ft]

4
12

2 6

0 0
0 150 300 450 600 750 900 1050 1200
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
52
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


1800 rpm
VTP 850X
Curve #: 11022-101104-E1

Q [gpm]
0 800 1600 2400 3200 4000 4800 5600 6400
150
514 mm
 
450
135  
482 mm  
 
120   400

450 mm
105 350
 

90   300
 
H [m]

H [ft]
  250
75
 

60 200

45 150

30 100

15 50

0 0

400 525
514 mm
350
450
482 mm
300
375
250 450 mm
P [kW]

300
P [hp]

200
225
150

150
100

50 75

0 0

9
24
NPSHr [m]

NPSHr [ft]

6
18

12
3
6

0 0
0 200 400 600 800 1000 1200 1400 1600
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
53
Pump Perfomance Curves 60 Hz

VTP 850XB Vertical Turbine Pumps (VTP)


1200 rpm
Curve #: 11047-130213-E1

Q [gpm]
0 500 1000 1500 2000 2500 3000 3500 4000
70
225

60 200
515 mm
 
 
 
  175
480 mm
 
50

450 mm 150
 
40  
  125
H [m]

H [ft]
 
 
30 100

75
20

50

10
25

0 0

105 140

515 mm
90 120

75 480 mm 100

60 450 mm 80
P [kW]

P [hp]

45 60

30 40

15 20

0 0

9
24
NPSHr [m]

NPSHr [ft]

6
18

12
3
6

0 0
0 100 200 300 400 500 600 700 800 900
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
54
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


1800 rpm
VTP 850XB
Curve #: 11047-130213-E1

Q [gpm]
0 800 1600 2400 3200 4000 4800 5600
150

450
135 515 mm
 
 
 
120   400
480 mm
 

105 450 mm 350


 

90   300
 
H [m]

H [ft]
  250
75
 

60 200

45 150

30 100

15 50

0 0

350

515 mm 420
300
360
250 480 mm
300
200
P [kW]

450 mm
P [hp]

240
150
180

100
120

50 60

0 0

15
45
NPSHr [m]

NPSHr [ft]

10
30

5 15

0 0
0 175 350 525 700 875 1050 1225 1400
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
55
Pump Perfomance Curves 60 Hz

VTP 1000 Vertical Turbine Pumps (VTP)


1800 rpm
Curve #: 11024-080704-S1

Q [gpm]
0 1000 2000 3000 4000 5000 6000 7000 8000

200
60
397 mm
η 70 η 73
55 η 76
78 175
375 mm
50
355 mm 78
45 150
η 76
40
η 73 125
35 η 70
H [m]

H [ft]
30 100

25
75
20

15 50

10
25
5

0 0

280
350
240
397 mm 300
200
250
375 mm
160
P [kW]

P [hp]

355 mm 200

120
150

80 100

40 50

0 0

40
120
NPSHr [m]

NPSHr [ft]

30
90
20 60

10 30

0 0
0 200 400 600 800 1000 1200 1400 1600 1800
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
56
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


1200 rpm
VTP 1000X
Curve #: 11053-131114-E1

Q [gpm]
0 600 1200 1800 2400 3000 3600 4200 4800 5400 6000
65
526 mm 220
60
 
  200
 
55 490 mm  
180
50
450 mm
45   160

40  
140
 
35
H [m]

H [ft]
  120

30
100
25
80
20
60
15
40
10

5 20

0 0

175

180
150
526 mm
150
125

490 mm
100 120
P [kW]

P [hp]

450 mm
75 90

50 60

25 30

0 0

9
24
NPSHr [m]

NPSHr [ft]

6
18

12
3
6

0 0
0 175 350 525 700 875 1050 1225 1400
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
57
Pump Perfomance Curves 60 Hz

VTP 1000X Vertical Turbine Pumps (VTP)


1800 rpm
Curve #: 11053-131114-E1

Q [gpm]
0 1000 2000 3000 4000 5000 6000 7000 8000
150
526 mm
450
135
   
490 mm  
120   400

105 450 mm 350

 
90 300
 
 
H [m]

H [ft]
75 250
 

60 200

45 150

30 100

15 50

0 0

450 600
526 mm

375 500
490 mm

300 400
450 mm
P [kW]

P [hp]

225 300

150 200

75 100

0 0

15
45
NPSHr [m]

NPSHr [ft]

10
30

5 15

0 0
0 250 500 750 1000 1250 1500 1750 2000
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
58
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


1800 rpm
VTP 1250
Curve #: 11025-080520-S1

Q [gpm]
0 1000 2000 3000 4000 5000 6000 7000 8000 9000

210

60 381 mm

180
360 mm η 68
50 η 72
340 mm η 76
150
η 78

40
η 78
H [m]

H [ft]
120
η 76

30 η 72

η 68 90

20
60

10 30

0 0

250

381 mm 300

200
250
360 mm

150 200
340 mm
P [kW]

P [hp]

150
100

100

50
50

0 0

24
NPSHr [m]

60
NPSHr [ft]

18

12 40

6 20

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
59
Pump Perfomance Curves 60 Hz

VTP 1300 Vertical Turbine Pumps (VTP)


1200 rpm
Curve #: 11026-081111-S1

Q [gpm]
0 800 1600 2400 3200 4000 4800 5600 6400

140

40 470 mm

448 mm η 72 120
η 76
35 η 80
424 mm η 82

30 100
η 82
η 80
25 80
η 76
H [m]

H [ft]
η 72
20
60

15

40
10

20
5

0 0

120
470 mm
150

100 448 mm
120
80 424 mm
P [kW]

P [hp]

90
60

60
40

20 30

0 0

60
15
NPSHr [m]

NPSHr [ft]

45
10 30

5 15

0 0
0 150 300 450 600 750 900 1050 1200 1350 1500
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
60
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


1800 rpm
VTP 1300
Curve #: 11026-081111-S1

Q [gpm]
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
320

90 470 mm
280
448 mm η 72
η 76
η 80
75 424 mm η 82
240

η 82
60 200
η 80
η 76
H [m]

H [ft]
η 72 160
45

120

30
80

15
40

0 0

400 470 mm
500

448 mm
320
400
424 mm
P [kW]

P [hp]

240
300

160
200

80 100

0 0

120
NPSHr [m]

33
NPSHr [ft]

90
22
60
11 30

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
61
Pump Perfomance Curves 60 Hz

VTP 1350 Vertical Turbine Pumps (VTP)


1200 rpm
Curve #: 11087-160202-F1

Q [gpm]
0 800 1600 2400 3200 4000 4800 5600 6400
60

55 180
463 mm
50
160

45 430 mm
140
40
400 mm
 
  120
35  
 
 
H [m]

H [ft]
30 100
 
 
25  
80
 
20  
60
15
40
10

20
5

0 0

120
463 mm 150

100
125
430 mm
80
100
P [kW]

P [hp]

400 mm
60
75

40 50

20 25

0 0

15
NPSHr [m]

45
NPSHr [ft]

10
30
5
15

0 0
0 200 400 600 800 1000 1200 1400 1600
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
62
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


1800 rpm
VTP 1350
Curve #: 11087-160202-F1

Q [gpm]
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
135

120 400
463 mm

105 350
430 mm

90 300
400 mm
 
 
 
75   250
 
H [m]

H [ft]
 
60   200
 
 
45   150

30 100

15 50

0 0

450 600

375 500
463 mm

300 400
430 mm
P [kW]

P [hp]

225 400 mm 300

150 200

75 100

0 0

18
NPSHr [m]

45
NPSHr [ft]

12
30
6
15

0 0
0 300 600 900 1200 1500 1800 2100 2400
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
63
Pump Perfomance Curves 60 Hz

VTP 1500 Vertical Turbine Pumps (VTP)


1200 rpm
Curve #: 11027-081205-E1

Q [gpm]
0 1000 2000 3000 4000 5000 6000 7000 8000
160

45 464 mm
140
η 76
40 437 mm η 80
η 82
η 84 120
35 410 mm

30 100
η 84
H [m]

H [ft]
25 η 82
η 80 80

20 η 76
60

15
40
10

20
5

0 0

160 210

140
464 mm 180
120
150
437 mm
100
P [kW]

120
P [hp]

410 mm
80
90
60

60
40

20 30

0 0

16 50
NPSHr [m]

40
NPSHr [ft]

12
30
8
20
4
10
0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
64
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


1800 rpm
VTP 1500
Curve #: 11027-081205-E1

Q [gpm]
0 1200 2400 3600 4800 6000 7200 8400 9600 10800 12000 13200

360
105
464 mm
320

90 437 mm η 76
η 80
η 82 280
η 84
410 mm
75
240

η 84
H [m]

200

H [ft]
60 η 82
η 80
160
45 η 76

120

30
80

15
40

0 0

464 mm 600
400

437 mm 500

300
410 mm 400
P [kW]

P [hp]

200 300

200
100
100

0 0

30
NPSHr [m]

75
NPSHr [ft]

20
50
10
25

0 0
0 250 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
65
Pump Perfomance Curves 60 Hz

VTP 1500KM Vertical Turbine Pumps (VTP)


1200 rpm
Curve #: 11089-160405-F1

Q [gpm]
0 800 1600 2400 3200 4000 4800 5600 6400 7200
50
160
463 mm
45
140
435 mm
40
 
   
  120
35 400 mm  

 
30 100
 
 
H [m]

H [ft]
25   80
 
20
60

15

40
10

20
5

0 0

140
463 mm 180
120
435 mm 150
100
120
400 mm
80
P [kW]

P [hp]

90
60

60
40

20 30

0 0

12
NPSHr [m]

30
NPSHr [ft]

8
20
4
10

0 0
0 200 400 600 800 1000 1200 1400 1600 1800
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
66
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


1800 rpm
VTP 1500KM
Curve #: 11089-160405-F1

Q [gpm]
0 1400 2800 4200 5600 7000 8400 9800 11200
120

463 mm 360
105

435 mm
90 300
   
 
 
 
400 mm
75 240
 

 
H [m]

H [ft]
 
60
 
180
 

45

120
30

60
15

0 0

500
463 mm
600
400
435 mm
500

300 400 mm 400


P [kW]

P [hp]

300
200

200

100
100

0 0

30
75
NPSHr [m]

NPSHr [ft]

20
50

10 25

0 0
0 300 600 900 1200 1500 1800 2100 2400 2700
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
67
Pump Perfomance Curves 60 Hz

VTP 1500L Vertical Turbine Pumps (VTP)


1800 rpm
Curve #: 11028-080704-S1

Q [gpm]
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000

240
70
394 mm
210
372 mm η 69
60
η 73
η 76 180
350 mm η 78
50
150
η 78
H [m]

H [ft]
40 η 76
η 73 120

η 69
30
90

20
60

10 30

0 0

400
280
350
374 mm
240
300
372 mm
200
250
P [kW]

P [hp]

350 mm
160
200

120
150

80 100

40 50

0 0

30 100
NPSHr [m]

NPSHr [ft]

75
20
50
10
25

0 0
0 250 500 750 1000 1250 1500 1750 2000 2250
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
68
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


1800 rpm
VTP 1500LH
Curve #: 11029-080830-S1

Q [gpm]
0 1200 2400 3600 4800 6000 7200 8400 9600 10800 12000
90
280

75
240
394 mm

377 mm η 66
60 200
η 72
η 76
355 mm η 80
η 80 160
H [m]

H [ft]
45
η 76
η 72
120
η 66
30

80

15
40

0 0

450 600

500
360
394 mm
400
270 377 mm
P [kW]

P [hp]

355 mm 300

180
200

90
100

0 0

24
NPSHr [m]

60
NPSHr [ft]

18

12 40

6 20

0 0
0 300 600 900 1200 1500 1800 2100 2400 2700 3000
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
69
Pump Perfomance Curves 60 Hz

VTP 1800M Vertical Turbine Pumps (VTP)


1800 rpm
Curve #: 11067-140320-S1

Q [gpm]
0 1500 3000 4500 6000 7500 9000 10500 12000
80

240
70 416 mm

395 mm
60 200
 
 
375 mm  
 
50
160
 
 
H [m]

H [ft]
40
 
120
 
30

80
20

40
10

0 0

375 500

416 mm

300 400
395 mm

375 mm
225 300
P [kW]

P [hp]

150 200

75 100

0 0

15
45
NPSHr [m]

NPSHr [ft]

10
30

5 15

0 0
0 300 600 900 1200 1500 1800 2100 2400 2700 3000
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
70
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


1200 rpm
VTP 1800X
Curve #: 11072-140620-S1

Q [gpm]
0 1000 2000 3000 4000 5000 6000 7000 8000 9000
50

491,5 mm 150
45

135
40 450 mm  
 
 
    120
35
 
410 mm 105
 
30  
  90
H [m]

 

H [ft]
25
75

20
60

15
45

10
30

5 15

0 0

210 280
491,5 mm
180 240

150 200
450 mm

120 160
P [kW]

P [hp]

410 mm
90 120

60 80

30 40

0 0

15
45
NPSHr [m]

NPSHr [ft]

10
30

5 15

0 0
0 250 500 750 1000 1250 1500 1750 2000 2250
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
71
Pump Perfomance Curves 60 Hz

VTP 1800X Vertical Turbine Pumps (VTP)


1800 rpm
Curve #: 11072-140620-S1

Q [gpm]
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000
120

110 360
491,5 mm

100
320
450 mm
90  
    280
 
80  
410 mm
 
  240
70  
 
H [m]

H [ft]
60   200

50 160

40
120
30
80
20

40
10

0 0

700
900
491,5 mm
600
750
500 450 mm
600
400
P [kW]

P [hp]

410 mm
450
300

300
200

100 150

0 0

30
90
NPSHr [m]

NPSHr [ft]

20
60

10 30

0 0
0 400 800 1200 1600 2000 2400 2800 3200
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
72
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


900 rpm
VTP 2200
Curve #: 11030-080728-S1

Q [gpm]
0 1200 2400 3600 4800 6000 7200 8400 9600 10800

100
30
542 mm
90

25
508 mm η 72 80
η 75
η 78
70
470 mm η 80
20
60
H [m]

H [ft]
η 80
15 η 78 50

η 75
η 72 40

10
30

20
5

10

0 0

120
150
542 mm
100
120
508 mm
80
P [kW]

P [hp]

470 mm 90
60

60
40

20 30

0 0

40
10.5
NPSHr [m]

NPSHr [ft]

30
7
20

3.5 10

0 0
0 250 500 750 1000 1250 1500 1750 2000 2250 2500
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
73
Pump Perfomance Curves 60 Hz

VTP 2200 Vertical Turbine Pumps (VTP)


1200 rpm
Curve #: 11030-080728-S1

Q [gpm]
0 1500 3000 4500 6000 7500 9000 10500 12000 13500 15000

180

50 542 mm
160

508 mm η 72 140
η 75
40
η 78
470 mm η 80 120
H [m]

100

H [ft]
30 η 80
η 78
η 75 80

η 72
20
60

40
10

20

0 0

280
360
542 mm
240
300
200 508 mm
240
P [kW]

P [hp]

160 470 mm
180
120

120
80

40 60

0 0

18 60
NPSHr [m]

NPSHr [ft]

12 40

6 20

0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
74
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


900 rpm
VTP 2200M
Curve #: 11032-080723-S1

Q [gpm]
0 1500 3000 4500 6000 7500 9000 10500 12000 13500

150
45

135
40
592 mm
120
35 565 mm

η 78 105
530 mm η 81
30 η 84
η 86
90
η 86
H [m]

H [ft]
25 η 84
η 81 75
η 78
20
60

15
45

10
30

5 15

0 0

280
200 592 mm

240
565 mm
160
200
530 mm
P [kW]

P [hp]

120 160

120
80

80
40
40

0 0

16
45
NPSHr [m]

NPSHr [ft]

12
30
8

4 15

0 0
0 350 700 1050 1400 1750 2100 2450 2800 3150
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
75
Pump Perfomance Curves 60 Hz

VTP 2200M Vertical Turbine Pumps (VTP)


1200 rpm
Curve #: 11032-080723-S1

Q [gpm]
0 2000 4000 6000 8000 10000 12000 14000 16000 18000

270
80

240
70
592 mm
210
565 mm
60
η 78
530 mm η 81 180
η 84
η 86
50
η 86
H [m]

150

H [ft]
η 84
η 81
40
η 78
120

30
90

20
60

10 30

0 0

500
592 mm
600

400 565 mm
500
530 mm
300 400
P [kW]

P [hp]

300
200

200

100
100

0 0

24 75
NPSHr [m]

NPSHr [ft]

16 50

8 25

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
76
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


1200 rpm
VTP 3000
Curve #: 11033-080813-S1

Q [gpm]
0 2500 5000 7500 10000 12500 15000 17500 20000 22500 25000

210

60

600 mm
180

50 η 76
560 mm η 80
η 83
η 85 150
520 mm
40 η 85
η 83
H [m]

120

H [ft]
η 80
30 η 76
90

20
60

10 30

0 0

750 1000

600 600 mm 800


P [kW]

P [hp]

450 560 mm
600

520 mm
300 400

150 200

0 0

75
20
60
NPSHr [m]

NPSHr [ft]

15
45
10 30
5 15

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
77
Pump Perfomance Curves 60 Hz

VTP 3400 Vertical Turbine Pumps (VTP)


900 rpm
Curve #: 11034-080723-S1

Q [gpm]
0 2000 4000 6000 8000 10000 12000 14000 16000

45 691 mm
140
40 657 mm η 72
η 76
η 78 120
622 mm
35 η 80

30 100
η 80

η 78
H [m]

H [ft]
25 η 76 80

η 72
20
60

15

40
10

20
5

0 0

300 400
691 mm
250
657 mm 320

200
622 mm
P [kW]

P [hp]

240
150

160
100

80
50

0 0

16
45
NPSHr [m]

NPSHr [ft]

12
30
8

4 15

0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
78
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


1200 rpm
VTP 3400
Curve #: 11034-080723-S1

Q [gpm]
0 2500 5000 7500 10000 12500 15000 17500 20000 22500

270
80 691 mm

657 mm 240
70 η 72
η 76
622 mm η 78
210
η 80
60

η 80 180
50
η 78
H [m]

150

H [ft]
η 76
40 η 72
120

30
90

20
60

10 30

0 0

800 1050

700 691 mm 900


600
657 mm
750
500
622 mm
P [kW]

600
P [hp]

400
450
300

300
200

100 150

0 0

24 75
NPSHr [m]

NPSHr [ft]

16 50

8 25

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
79
Pump Perfomance Curves 60 Hz

VTP 3400M Vertical Turbine Pumps (VTP)


720 rpm
Curve #: 11035-080702-S1

Q [gpm]
0 2000 4000 6000 8000 10000 12000 14000
160

45
770 mm 140
40
735 mm
120
35 700 mm
η 76
η 80
η 83
30 η 85 100
H [m]

H [ft]
25 η 85 80
η 83
20 η 80
60
η 76
15
40
10

20
5

0 0

250

300

200
770 mm
250
735 mm
150 200
P [kW]

700 mm
P [hp]

150
100

100

50
50

0 0

8 25
NPSHr [m]

20
NPSHr [ft]

6
15
4
10
2
5
0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
80
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


900 rpm
VTP 3400M
Curve #: 11035-080702-S1

Q [gpm]
0 2000 4000 6000 8000 10000 12000 14000 16000 18000

240
70
770 mm
210
60 735 mm

700 mm 180
η 76
50 η 80
η 83
η 85 150
H [m]

H [ft]
40
η 85
120
η 83
30 η 80
η 76 90

20
60

10 30

0 0

450 600

400
770 mm 500
350
735 mm
300 400
P [kW]

700 mm
P [hp]

250
300
200

150 200

100
100
50

0 0

16
50
NPSHr [m]

NPSHr [ft]

12 40
30
8
20
4
10
0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
81
Pump Perfomance Curves 60 Hz

VTP 3400M Vertical Turbine Pumps (VTP)


1200 rpm
Curve # : 11035-080702-S1

Q [gpm]
0 2500 5000 7500 10000 12500 15000 17500 20000 22500 25000
450

120 400
770 mm

735 mm 350
100
700 mm
η 76 300
η 80
η 83
80 η 85
250
H [m]

H [ft]
η 85

60 η 83 200
η 80
η 76
150
40

100

20
50

0 0

1500

1000
1250
770 mm
800
735 mm 1000
P [kW]

700 mm
P [hp]

600
750

400
500

200 250

0 0

80
NPSHr [m]

NPSHr [ft]

20
60

40
10
20

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
82
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


600 rpm
VTP 6500
Curve #: 11036-090310-S2

Q [gpm]
0 4000 8000 12000 16000 20000 24000 28000

140

40 870 mm

830 mm 120
35
η 78
780 mm η 83
30 η 86 100

η 88

25 80
η 88
H [m]

H [ft]
η 86
20 η 83
η 78 60

15

40
10

20
5

0 0

600

400
870 mm
500

830 mm
300 400
P [kW]

P [hp]

780 mm
300
200

200

100
100

0 0

9 30
NPSHr [m]

NPSHr [ft]

6 20

3 10

0 0
0 800 1600 2400 3200 4000 4800 5600 6400 7200
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
83
Pump Perfomance Curves 60 Hz

VTP 6500 Vertical Turbine Pumps (VTP)


720 rpm
Curve #: 11036-090310-S2

Q [gpm]
0 5000 10000 15000 20000 25000 30000 35000

210

60 870 mm

830 mm 180

50 η 78
780 mm
η 83 150
η 86
η 88
40
H [m]

120

H [ft]
η 88
η 86
30 η 83
90
η 78

20
60

10 30

0 0

900 1200

750 1000
870 mm

600 830 mm 800


P [kW]

P [hp]

780 mm
450 600

300 400

150 200

0 0

16
45
NPSHr [m]

NPSHr [ft]

12
30
8

4 15

0 0
0 1000 2000 3000 4000 5000 6000 7000 8000
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
84
Pump Perfomance Curves 60 Hz

Vertical Turbine Pumps (VTP)


900 rpm
VTP 6500
Curve #: 11036-090310-S2

Q [gpm]
0 5000 10000 15000 20000 25000 30000 35000 40000 45000

350
105

870 mm
90 300
830 mm

75 780 mm η 78 250
η 83
η 86
η 88
H [m]

200

H [ft]
60
η 88
η 86
45 η 83 150
η 78

30 100

15 50

0 0

1600 2100

1400
870 mm 1800
1200
830 mm 1500
1000
P [kW]

P [hp]

780 mm 1200
800
900
600
600
400

200 300

0 0

18 60
NPSHr [m]

NPSHr [ft]

12 40

6 20

0 0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
Q [m³/h]

Notes:
1. Operating data certified to ISO 9906 Hydraulic performance 4. Elevated temperature effects on performance are not included
acceptance tests - Grades 1 & 2 5. Consider 3.0% efficiency derate if operated Off-BEP (60% - 80%)
2. Performance based on single stage pumping clean non-aerated 6. Consider 2.0% efficiency derate if using balanced impellers
water (H2O T°=18 [°C], H2O Density = 998 [kg/m3])
7. Specifications are subject to change without previous notice.
3. Power and efficiency losses are not reflected on the curve
85
OFICINAS CENTRALES
Avda. Circunvalación 64B - Iquique, Chile
Tel: (+56) (57) 2424685 - Fax: (+56) (57) 2425504
e-mail: info@neptunopumps.com

w w w. n e p t u n o p u m p s . c o m
w w w. n e p t u n o e n e r g y. c o m

NP-PPC-5016R3
NP-PPC-6016R3

Hacia una economía circular comprometida con el medio ambiente.


Neptuno3R™ - Reutiliza, Reduce y Recicla: Debido a la actual escasez y alto valor de las materias
primas, creemos en la necesidad de transitar hacia una economía circular que reutilice los materiales
y que permita mitigar los efectos del cambio climático. Nos sentimos orgullosos de ser una empresa
de diseño y manufactura que reutiliza y recicla desechos industriales metálicos para producir nuevos
productos de alta eficiencia energética, contribuyendo al aprovechamiento máximo de los recursos y
disminuyendo los efectos del calentamiento global. Para saber más sobre nuestras capacidades visite:
www.neptunopumps.com/3R

Neptuno®, Neptuno Pumps®, Innovation that flows™, VTPSelector™, Neptuno Barge Pump System™ and any and all Neptuno Pumps Ltda. brand, product, service and feature names, logos and slogans are trademarks or registered
trademarks or trademarks of Neptuno Pumps Ltda. All other brand, product, service and feature names or trademarks are the property of their respective owners. This brochure is for general presentation only. All performances and/or
applications shown are only for general information and may not be applied for every case. For actual pump performance and information please contact us. This brochure does not provide any warranty or guarantee of any kind. Directions
for use and safety will be given separately with any purchase. We are constantly improving the performance of our equipment and therefore reserve the right to make alterations to the information without previous notice. This publication
is the property of Neptuno Pumps Ltda. Reproduction of all or any portion of this material is prohibited by law.

Copyright © Neptuno Pumps Ltda. All Rights Reserved.

You might also like