This document provides design details for a 5000 cubic meter diesel fuel storage tank. Key specifications include: the tank will store diesel fuel; it will have a diameter of 25 meters and height of 10.8 meters; the tank material will be A283 Grade C or A36 steel; it will be designed and constructed according to API Standard 650; and include features like a supported cone roof, internal piping, and cathodic protection.
This document provides design details for a 5000 cubic meter diesel fuel storage tank. Key specifications include: the tank will store diesel fuel; it will have a diameter of 25 meters and height of 10.8 meters; the tank material will be A283 Grade C or A36 steel; it will be designed and constructed according to API Standard 650; and include features like a supported cone roof, internal piping, and cathodic protection.
This document provides design details for a 5000 cubic meter diesel fuel storage tank. Key specifications include: the tank will store diesel fuel; it will have a diameter of 25 meters and height of 10.8 meters; the tank material will be A283 Grade C or A36 steel; it will be designed and constructed according to API Standard 650; and include features like a supported cone roof, internal piping, and cathodic protection.
1 PROJECT NAME : Storage Tank 5000 KL 2 EQUIPMENT NAME : DIESEL FUEL STORAGE TANK 3 DESIGN DATA 4 Fluid Handled : Diesel Fuel True Vapor Pressure (barg) : 0.014 5 Flammable / Toxic / Corrosive / Lethal : Yes / No / No / No Flash Point (oC) : 74 6 Density (kg/m3) : 810 - 890 Capacity (Nominal / Working) (m3) : 5000 7 Code (Design and Construction) : API Standard 650 Pumping Rate IN : 15 8 Operating Pressure (barg) : Atmospheric Pumping Rate OUT (m3/h) : 5 9 Operating Temperature (oC) : Ambient Wind Velocity (m/s) : 36 10 Design Pressure (barg) : Full of water Seismic Design : API std. 650 Appendix E 11 Design Temperature (max/min) (oC) : Ambient Seismic Zone : 1 12 Hydrotest Pressure (barg) : as per API 650 Zone Factor : 0.075 13 Inside Diameter (mm) : 25000 Importance Factor : 1 14 Height (mm) : 10800 Soil Profile : SE 15 Corrosion Allowance (mm) : 1.5 (Shell & Roof) 16 Corrosion Allowance (mm) : 1.5 (Bottom Plate) Roof Loads 17 Radiography : as per section 6 of API 650 Uniform Live Load (psf) : 25 18 Stress Relief : N/A Special Load (psf) : NA 19 Insulation : N/A Insullation Load (psf) : NA 20 Painting Shell / Roof (External) : Yes 21 Painting Shell / Roof (Internal) : 1st shell Weight 22 Painting Bottom Plate (Exterior) : Yes Erection (kg) : 136000 23 Painting Bottom Plate (Interior) : Yes Operational (kg) : 140250 24 Painting Structural : Yes Hydrotest (kg) : 145250 25 MATERIALS 26 Roof : A 283 Gr C or A 36 Structural : A 36 27 Shell : A 283 Gr C or A 36 Internal (Pipe/Plate) : A 106 Gr B / A 36 28 Bottom : A 283 Gr C or A 36 Bolts : A 193 B7 29 Pipe : A 106 Gr B Nuts : A 194 2H 30 Flanges : A 105 or A 283 Gr C or A36 Internal/External Clip & Support : A 283 Gr C or A 36 31 Fittings : A 234 WPB Internal Attachment : A 283 Gr C or A 36 32 Manhole : A 283 Gr C or A 36 Anchor Bolt : A 307 33 CONSTRUCTION DETAIL 34 Shell Courses Roof 35 No. of Courses : 6 Type : Supported cone 36 Height : 10.8 Thickness : 6mm 37 Thickness : 12,10,10,8,8,7 Type of Joints : as per API 650 Slope of Pitch : 12deg 38 Foundation Bottom Plate Construction 39 Type : Thickness : 12,10 40 Cathodic Protection System : No Diameter : 25100 41 Under tank Leak Detection : Yes Type of Joints : fillet 42 Slope of Pitch : 2% 43 MISCELLANEOUS 44 Circular Stairways or Straight ladder : Circular Stairway and Ladder Gauge Hatch : Yes 45 Walkway/Platform around Periphery : N/A Draw of Sump : Yes 46 Internal Coil or Heather : N/A Insulation Support : No 47 Lightning Protection : N/A Earthing Boss : Yes DIESEL FUEL STORAGE TANK REVISION :0 MECHANICAL DATA SHEET 1 PROJECT NAME : Storage Tank 5000 KL 2 EQUIPMENT NAME : DIESEL FUEL STORAGE TANK 48 NOTES 49 1. Design, fabrication, erection and testing requirement shall be in accordence to API Standard 650, Latest Edition 50 2. The thickness to be calculated as per code 51 3. Manway should supply with davit, gasket, bolts, nuts and washer 52 4. Nozzle schedule / thickness and projection shall be as per API 650 53 5. All external nozzle localized stress analisys to be performed by supplier as per WRC 107 & 297 bulletin 54 6. Gasket material shall be 0.175" non asbestos 55 7. Bolts and Nuts should be coated with fluoro carbon 56 8. Bottom of tank should be slopeto drain collection 57 9. Tank should be equiped with ladders and handrails (top of tank) for maintenance purpose. 58 10. Hold nozzle orientation and elevation 59 11. VTA = Vendor to advice 60 12. Minimum space from CL of nozzle to steel level = 500 mm 61 13. Weep hole to be provided to prevent siphoning 62 14. Internal pipe to be completed with clamp and bolting with double nut