NOTES FOR ALL DRAWINGS:


PV MODULE RATINGS @ STC 
OCPD = OVERCURRENT PROTECTION DEVICE *SIGN FOR DC DISCONNECT
MODULE MAKE AMERICAN SOLAR
NATIONAL ELECTRICAL CODE® REFERENCES PHOTOVOLTAIC POWER SOURCE
MODULE MODEL AS‐360 SHOWN AS (NEC XXX.XX)
MAX VOLTAGE 495 V
MAX POWER-POINT CURRENT (IMP) 9.1 A
MAX CIRCUIT CURRENT 12.1 A
MAX POWER-POINT VOLTAGE (VMP) 39.4 V DC‐TO‐DC CONVERTER RATINGS (if used)
MAX OUTPUT CURRENT N/A
OPEN-CIRCUIT VOLTAGE (VOC) 47.4 V CONVERTER MAKE
WARNING: ELECTRICAL SHOCK
SHORT-CIRCUIT CURRENT (ISC) 9.7 A CONVERTER MODEL HAZARD–LINE AND LOAD MAY BE
ENERGIZED IN OPEN POSITION
MAX SERIES FUSE (OCPD) 25 A MAX CURRENT

MAXIMUM POWER (PMAX) 360 W MAX VOLTAGE SIGN FOR PV SYSTEM DISCONNECT


SOLAR PV SYSTEM
MAX VOLTAGE (TYP 1000VDC) 1000 V MAXIMUM POWER DISCONNECT
o o
VOC TEMP COEFF (mV/ C or %/ C ) -0.28 MAX OUTPUT CIRCUIT V (TYP 600VDC) AC OUTPUT CURRENT 32 A

NOMINAL AC VOLTAGE 240 V
INVERTER RATINGS 

INVERTER MAKE AMERICAN CONVERTER
SIGN FOR DISTRIBUTION PANELS
NOTE FOR ARRAY CIRCUIT WIRING THIS PANEL FED BY MULTIPLE
INVERTER MODEL AC‐7600i SOURCES (UTILITY AND SOLAR)
LOWEST EXPECTED AMBIENT TEMPERATURE
BASED ON ASHRAE MINIMUM MEAN EXTREME DRY MAX DC VOLT RATING 600 V
BULB TEMPERATURE FOR ASHRAE LOCATION SIGN FOR NEC 705.12(D)(2)(3)(b) (if used)
o
MOST SIMILAR TO INSTALLATION LOCATION. MAX POWER @ 40 C 7680 W
LOWEST EXPECTED AMBIENT TEMP -12 oC WARNING:
NOMINAL AC VOLTAGE 240 V INVERTER OUTPUT CONNECTION;
DO NOT RELOCATE THIS
MAX AC CURRENT 32 A OVERCURRENT DEVICE.

MAX OCPD RATING 40 A


SIGN FOR NEC 690.12 (for roof‐mounted systems)
NOTES FOR INVERTER CIRCUITS:
PHOTOVOLTAIC SYSTEM
1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE EQUIPPED WITH RAPID SHUTDOWN
REQUIREMENT? YES NO N/A

2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE


REQUIREMENT? YES NO N/A *NOTE: MICROINVERTER AND AC MODULE SYSTEMS DO NOT NEED DC DISCONNECT 
SIGN SINCE 690.51 MARKING ON PV MODULE COVERS NEEDED INFORMATION
3) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER
OCPD AMPERE RATING. (See Table 705.12)

4) DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR RULE IN


Contractor Name,
Address and Phone:
Notes for One-Line Standard Electrical
705.12(D)?
YES NO SolarBright Diagram for Single-Phase PV Systems
2688 Washington St.
Alexandria, VA Site Name: Joe and Jane Homeowner
800-555-1212 Site Address: 2400 Monroe St., Alexandria, VA
System AC Size: 7.6 kWac
SIZE FSCM NO DWG NO REV
Drawn By: Bill
E1.2a
Checked By: Ted SCALE NTS Date:    SHEET