H Overall Length (L)

Cable Type A - Conductor Same Side Exposed Specifications


Conductor
Upper Insulator Section
Materials
Conductor: Tinned Copper

Cable Width (W)


Lower Insulator
Insulation: Flame retardant polyester, White
Supporting Tape: Polyester, Blue
Lower Support Strips
Conductor

G
Width

Electrical
Voltage Rating: 60V
Current Rating: 0.5mm pitch=0.5A
A
Pitch

1.0mm pitch=1A

Exposed Mechanical & Environmental


Cable Width (W)
Conductor Operating Temperature: 80°C
F
Conductor
Thickness

Length Pitch (mm) Total Cable Width (mm) (High Temperature version available, contact GCT)
Cable Type D - Conductor Opposite Side
4mm 0.5 x (No. of Conductors+1) ± 0.08mm
Durability: 30 Cycles
0.50
Exposed Conductor Upper
1.00 1.0 x (No. of Conductors+1) ± 0.15mm Upper Insulator Support Strip
Section
Conductor Notes
Lower Insulator Exposed
Lower Support Strip Conductor
No Printing on cable.
E Section For tolerance information, contact GCT
Support Strip Length

Total Thickness
0.3±0.05mm
For non-standard options, contact GCT
Support Strip and Plating Options by Pitch
D - Exposed conductor length
- Support tape length
Pitch Support Strip Plating Options (conductor thickness x width (mm)) - Conductor thickness/width
D (mm) Length (mm) Tin Gold - Folding/bending to an angle
- High Temp. 105°C and Voltage: 60V
0.50 6.00 0.035 x 0.3 (A) 0.035 x 0.3 (A)
Ordering Grid
0.035 x 0.65 (D)
0.035 x 0.65 (D) Request Samples
1.00 8.00 0.05 x 0.65 (E)
0.1 x 0.65 (C)
0.05 x 0.65 (E) XX XX X XXXX X X and Quotation
Pitch Plating
05 = 0.50mm T = Tin (Standard) (MOQ 2,000 pcs)
C Special Shielding Options (Contact GCT) 10 = 1.00mm (MOQ 5,000 with Shielded and Shielded/Grounding)
Number of Conductors G = Gold (Conductor Thickness x Widths A, D & E only)
Material Usage Earth Drain Remarks 06-80 (0.50mm pitch) (MOQ 5,000 pcs)

Aluminium foil with 04-50 (1.00mm pitch)


Polyester film Conductor Thickness x Width
General shielding Yes
conductive glue (Standard) Cable Type A = 0.035 x 0.3 (0.50mm pitch only)
laminated
non-conductive A = Conductor Same Side D = 0.035 x 0.65 (1.00mm pitch only)
Copper foil with High performance
Yes surface D = Conductor Opposite Side E = 0.05 x 0.65 (1.00mm pitch only)
conductive glue shielding
C = 0.1 x 0.65 (1.00mm pitch only) (Tin plating only)
B Overall Length (L)
Shielding Grounding Conductors
Decide the conductor numbers you require Specify cable length (Minimum = 30mm)
Conductor 1 grounded to the shield. eg 0030 = 30mm
A 0100 = 100mm
On Cable type A, the position of conductor
1 is Immaterial
Part Number Product Description
Conductor 1
Please take note, however, of the position N/A Flat Flex Cable Ordering Information
D
Drawing Date
of conductor 1 on cable type D (see left)
A 23rd May 2011
By CC Tolerances (Except as Noted) This drawing is confidential and
www.gct.co
Units:
Length Angle copyright of Global Connector
Drawing Metric (mm)
Detail

Revision
Release
A4
C Technology, Ltd (GCT).
This drawing must not be copied
or disclosed without written Not to Drawn By Sheet No.
Date 03/02/17 3rd Angle Projection consent. E & OE Scale SA 1/1
1 2 3 4 5 6 7 8