Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

C.

Other Flexural Parameters

fsvert = 183.33 MPa ccvert1 = 75 mm


fshor = 183.33 MPa ccvert2 = 75 mm
ρl = 0.0015 cchor1 = 87 mm
ρt = 0.0025 cchor2 = 87 mm
2
Abarvert = 113.10 mm
2
Abarhor = 113.10 mm

D. Control of Flexural Cracks


280 280
𝑠 = 380 − 2.5𝑐 𝑠 = 300
𝑓 but not greater than 𝑓

smaxvert1 = 375 mm smaxhor1 = 350 mm


smaxver2 = 375 mm smaxhor2 = 350 mm

Mu Rn ρ ρmin2 ρuse s suse


HOR BARS 11.15 0.2891 0.0011 0.0014 0.0014 375 350 OK!
SIDE 1
VER BARS 19.22 0.4452 0.0016 0.0015 0.0016 300 300 OK!
HOR BARS 49.79 1.2910 0.0048 0.0025 0.0048 100 100 OK!
SIDE 2
VER BARS 48.21 1.1168 0.0041 0.0015 0.0041 100 100 OK!

SIDE 1
HOR BARS 12mmφ spaced at 350mm o.c.
VERT BARS 12mmφ spaced at 300mm o.c.

SIDE 2
HOR BARS 12mmφ spaced at 100mm o.c.
VERT BARS 12mmφ spaced at 100mm o.c.

𝑀 0.85𝑓 𝑐 2𝑅
𝑅 = 𝜌= 1− 1−
𝜑𝑏𝑑 𝑓 0.85𝑓 𝑐

𝐴 𝑓
𝐹 = ∅(0.17𝜆 𝑓 𝑐 + )
E. Check for Shear Capacity 𝑠 𝑠

𝐴 = 0.7854∅

Fv = 0.75 MPa
SQX = 0.71 MPa DCRx = 0.94 OK!
SQY = 0.73 MPa DCRy = 0.97 OK!

THICKNESS IS OK!

You might also like