Download as pdf
Download as pdf
You are on page 1of 14
anneed 1 a. CanNeed-EMS-200 Multiple Lid Measurement Station User Manual CanNeed Instrument (HK) Limited CanNeed Instrument (Zhaoging) Ltd. (China office) ‘Duanzhou Industrial Town, Donghu Road South, Duanzhou. District, Zhaoqing, Guangdong Province, PR. China 526060 ‘Tel:+86-758-2788469,2311786 FAX:+86-758-2782729 Email: info@canneed.com Attp://www.canneed.com ‘CanNeod isthe registered trademark of CaniNeed Instrument (HK) Limited ‘Copyright © CanNeod Instrument (HK) Limited —<__ CariNeed-EMS-200 Multiple Lid Measurement Station 15, 16. 17, 18, (CanNeed Instrument (HK) Ltd ‘User Manual eusaved_instrerent Lea worm.canneed.com Contents ‘Transport Package and Unpacking ; ‘Preparation for Installation and ‘Commissioning. ‘Technical Data Features. Intended Use Mechanical Structure and Parts. Goods to Be Received (Picture 3 &4). Installation...... Calibration.. Parameters Setting. ‘Test Method..... _ ‘Settings and Interface. Advanced Setting. 13.1 Correction Setting for Countersink and Thimble Depth. 13.2 Data Transport, 13,3 Protocol. 13.4 Data Format..... CND_EMS 1.0 Software. CanNeed Instrument (HK) Ltd. www.canneed.com ‘Tel: +86-758-2788469,2311786 FAX: +86-758-2782729, Email: info@canneed.com [i ef! | (CariNeed Instrument (HK) Lid User Manual [Ceemneeg tostranent Us] worw.canneed.com 1. Transport Package and Unpacking EMS-200 Multiple Lid Measurement Station is transported in export master cartons. Ease of unpacking: only need — to xemove the outer cartons. ~ 2.Preparation for Installation and Commissioning ‘Take the tester ftom the outer package and check if there is any damage, ‘Check the packing list. Prepare clean air source with adequate air pressure to meet the test requirements, Connect the air source. The machine adopts an air source connection of 6 mm, Awe 3.Technical Data Accuracy: 40.01 mm 41 digit Data output: RS232C ‘Measure unit: mm Power supply: 230V/S0Hz, — Air supply: 6 bar Dimension: 560X400 X370 mm ~ Net weight: 22 kg ~ 4,Features “EMS-200 Multiple Lid Measurement Station’ is the standard equipment for end making industry Measure End Hook Curl diameter, End Curl Height, Countersink and Thimble Depth at the same time Data can be seat to SPC with RS232C data output Equipped with PLC Touching sereen control system, data can be collected automatically ‘Number of measure point cen be set Hiigh accuracy Equipped with calibration ring gauge, easy for calibration Single test result can be reviewed after lots of samples are tested. Average, maximum and minimum values are calculated automatically. Safety design CanNeed Instrument (HK) Ltd. www.canneed.com 3 - Tel: #86-758-2788469,2311786 FAX: 486-758-2782729, Email: info@cenneed com (CanNeed-EMS-200 Multiple Lid Measurement Station ‘CanNeed Instrument (HK) Ltd ‘User Manual Canneed instr Ltd www.canneed.com 5.intended Use ‘CanNeed-EMS-200 Multiple Lid Measurement Station is for measuring the End Curl Outer Diameter, End Curl Height, Countersink and Thimble Depth. The end countersink is the height of countersink position minus the thickness of plate. Place the ends on the testing platform, select the measure points, then press “start”. The four pneumatic controlled sensors will start to measure the sample ends automatically at the same time. The sample ends will be rolled automatically to change the measure points. For every circle, the amount of measure points can be set ftom 1 to 50. ‘Measurement results can be exported by the RS232 date wire, Mechanical Structure and Parts 1, Airsource processor 2, Sensorbox 3, Touching screen 4, Test button 5, Power switch Picture 1 EMS-200 Multiple Lid Measurement Station Sketch Map 6, Sensor measuring head 7. Driving wheel 8, Sample end 9, Rotation axis 10, Screw mut of linear scale Picture 2 EMS-200 Measuring Parts Sketch CanNeed Instrument (HK) Ltd. | www.canneed.com 4 ‘Tel: +86-758-2788469,2311786 FAX: +86-758-2782729, Email: info@canneed.com ‘CanNeed-EMS-200 Multiple Lid Measurement Station (CaniNeed Instrument (HK) Ltd User Manual wwwe.canneed.com 7.Goods to Be Received (Picture 3 & 4) Picture 3 Main Machine (One set) Picture 4 Calibration Ring Gauge (Refer to packing list for details of quantity and size) 8. Installation ‘The tester is easy to be installed, Please read the technicel data cerefully in the manuel before installation. Make sure the air source matches with the machine, ‘Take the tester ffom the package, check if there is damage or not. (Check with the packing list, (Cary out the test in clean, neat, dry and pollution-fee laboratory. ‘Connect the power supply. Caution: make sure the source voltage matches the rated voltage! ‘Connect the compressed air, adjust the pressure to 0.5 Mpa, The maximum is 0.6 MPa, (Please pull up cover of the part (1) Air Source Processor, increasing pressure by rotating it clockwise, decreasing pressure by rotating it anti-clockwise), BRYA 6. Tum on the power switch. Test can be started now. CanNeed Instrument (HK) Ltd. www.canneed.com . ‘Tel: +86-758-2788469,2311786 FAX: +86-758-2782729, Email: info@eanneed.com CariNeed-EMS-200 Multiple Lid Measurement Station CanNeed Instrument (HK) Ltd ‘User Manual Genness instranent Lt veww.canneed.com Calibration Enter the “Setting” interface and press “Advanced”, Input the code (11111111) to enter the “Advanced” Setting, EMS-200 Multiple Lid Measurement Station Press “Calibration” to enter. Press “Zero” button, the displacement sensors and linear scale will be zeroed out. After pressing the button, the four measuring heads of the displacement sensors will stretch out and be cleared. “Probe Control” controls the four displacement sensors. Calibration procedures: © Tum on the tester, unscrew (10) “Screw nut of linear scale” (Picture 2), and move (9) “Rotation axis” (Picture 2) to the leftmost side. Then tighten the “Screw nut” (Picture 2). ® Press “Zero” to clear the sensors and lineer scale (Set zer0) @® Place the ring gauge on the testing platform (below picture), make sure the ring gauge do not touch (6) “Sensor measuring head” (Picture 2). Otherwise the measuring head cannot stretch out or draw back and result in fault. CanNeed Instrument (HK) Lid. | www.canneed.com “Tel: +86-758-2788469,2311786 FAX: +86-758-2782729, Email: info@sanneed.com ‘CariNeed-EMS-200 Multiple Lid Measurement Station ‘CanNeed Instrument (HK) Ltd ‘User Manual Esnneed instronent Ua wirw-canneed.com ® Press the “Probe control’ button to let the measuring head touch the ring gauge, Real-time value will be displayed on the screen. Real-time value = test valuexslope. If the real-time value does not agree with the standard, please modify the value by adjusting the slope. 10. Parameters Setting Press “Setting” to enter the setting interface, |EMS-200 Multiple Lid Measurement Station Measure Point’: To set the number of measure points of an end. Setting range is: 1-50. "Correction Value for Countersink’: to correct the countersink test value. The value is related to the thickness of the end plate, There are 10 different groups of correction values for your option. The administrator is entitled to modify and set the correction values. Users can only choose the value. The principle and method of setting the “Correction value for countersink”: when the correction value is zero, use CanNeed EMS-200 to measure the first sample can end, then the countersink value is A. Then use CanNeed CSG-d Countersink Gauge to measure the first sample end countersink, and the value is B. Finally the correction value for countersink of the first sample end is C=A-B. CanNeed Instrument (HK) Ltd. | www.canneed.com i Tek: +86-758-2788469,2311786 FAX: +86-758-2782729, Email: info@canneed com User Manual www.canneed.com “Correction Value for Thimble Depih”: to correct the test value of the thimble depth. The value is related to ead curve, set value and measuring position, There are 10 different groups of correction values for your option, The ‘edministrator is entitled to modify and set the correction values. Users can only choose the value. © CanINeed-EMS-200 Multiple Lid Measurement Staton iT TT | BBE | | ConNocd instrument (HK) Lid [Ganneed instrument Led] 11. Test Method ~ 1) Unserew the Screw mut (10, Picture 2), move the rotation axis to the leftmost side and tighten the screw mut (10, Picture 2) to fix the sliding block of the linear scale, Press the ‘Zero’ button to clear the sensors and Tinear scale 2) Unscrew the part (10, Picture 2), move the lineer scale to the right side slowly till the sample end can be Placed in, Place the sample end and move the linear scale tothe left slowly till the sample presses the driving Wheel (7, Picture 2), Let the sensor meesuring heads point to the countersink and cur! position respectively. Screw the screw nut (10, Picture 2) to fix the sliding block of the linear scale. Press the ‘STAR? button to start the measurement. 3) Ifthe same sample is tested again, please move the driving wheel (7, Picture 2) tothe left by hand, place the ~ sample in, let go your hand and the driving wheel will reset itself, and then start the measure again. 4) Asroup of data will be recorded after measuring a sample end. Press “Data” button to check the data — Press “+/-* button under the ‘End No’ to check all the data of each different end. Press ‘+/-" button under ‘Measure Point” to check the data of each measure point of an end. — Press ‘Delete All Data’ to delete all the data. 99 pieces of ends’ data can be saved at most (50 measure points at ‘most for one end). More data cannot be saved if memory is full, Please delete the data in time. Caution: 1. Do remember to clear the displacement sensors and linear scale after restarting the equipment. 2, Do remember to move the linear scale slowly. CanNeed Instrument (HK) Ltd. | www.canneed.com 2 ‘Tel: +86-758-2788469,2311786 FAX: +86-758-2782729, Email: info@eanneed com a CC ‘CariNeed-EMS-200 Multiple Lid Measurement Station (CaniNeed Instrument (HK) Ltd User Manual “Conners Instrasent www.canneed.com 12. Settings and Interface ‘Connect the power supply; the touch-screen enters the measure interface. End No “Start” button: start the measurement. (Better to use the “Test” button on the panel of the tester (3, Picture 1) 10 start the mes ment.) “Stop” button: stop the measurement. “Zero” button: to clear the displacement sensors end linear scale. “Setting” button: to enter the setting interface. “Data” button: to enter the data interface. “End No.”: to indicate the end number during current measurement. “Measure point”: to indicate the number of measure points during current measurement. Curl Outer Dismeter, Curl Height, Countersink and Thimble Depth show the measure values for current end positions. “Zero”: before the displacement sensors and linear scale are cleared, the following screen will appear: CanNeed Instrument (HK) Ltd. | www.canneed.com ° “Tl: +96-758-2788460,2311786 FAX: 486-758-2782729, Email: info@eann ~ CaniNeed-EMS-200 Multiple Lid Measurement Station (CanNeed Instrument (HK) Ltd ‘User Manual commend instranent Ces wirmcanneed.com - 13. Advanced Setting ~ 13.1 Correction Setting for Countersink and Thimble Depth “Correction Setting for Countersink”: Administrator can set 10 groups of correction values for countersink, “ “Correction Setting for Thimble Depth”: Administrator can set 10 groups of correction values of countersink. EMs-200 Multiple Lid Measurement Station Press and choose the corresponding number for “Item”, and modify corresponding number from 1 to 10; Press and choose the corresponding number for “Set Value”, and modify corresponding correction value for countersink, 13.2 Data Transport Data are sent through RS-232 cable to the host computer. |EMS-200 Multiple Lid Measurement Station | ‘Press ‘Data Transport” button on the touch-screen (factory default is ON) to enter and select ‘ON’ to activate the data transport fumetion. Press “SPC” button, data will be sent to the SPC system. Press “Software” button, data will be sent to the proprietary software CND_EMS 1.0. CanNeed Instrument (HK) Lid. | www.canneed.com 0 a Tel: +86-758-2788469,23 11786 FAX: +86-758-2782729, Email: info@eanneed.com ~ — CanNeed-EMS-200 "Multiple Lid Measurement Station (CanNeed Instrument (HK) Ltd User Manual 13.3 Protocol at Baudrate | 9600 Startbit [1 [uate _[s Stopbit [1 13.4 Data Format Data is hex format — For exemple nd Curl outer diameter 65,00 / End Cust height 2.00/ Countersink: 3,00 Export Dataare: AAAA 0001 1964 oocg 012C FRFF — AAA: Start data transport 0001: Numbers of measure points 1964 00C8_ 012C: Measure results FFF: Stop data trensport 13.5 Modify Password Modify the pessword to enter the Advanced Setting, ~ 14, Maintenance ‘The product does not need much care or maintenance, Surface cleaning: Only need to clean the Surface of the product with slightly damp and soft cloth, : 13. Other Cautions CanNeed Instrument (HK) Ltd. www.canneed.com ay ‘Tel: +86-758-2788469,2311786 FAX: +86-758-2782729, Email: info@canneed.com CariNeed-EMS-200 Multiple Lid Measurement Station CaniNeed Instrument (HK) Ltd ‘User Manual Coaneed Instraneni Lid worw.canneed.com 16. Troubleshooting ‘there is error detected in the displacement sensors, the following indication will appear on the touch-screen feted ee Possible causes: ‘When the calibration ring gauge or sample end is placed on the testing platform, please do NOT let the ring ‘gauge or sample end touch the “Sensor measuring head” (6, Picture 2). Otherwise the messuring head cannot stretch cut and an error will occur. - Quick Setup Guide Unpack the master carton; place the tester horizontally and stably on the operation platform, 2. Turn on the air supply, connect the air source with the air inlet fitting and adjust the air inlet pressure, 3. Calibrate the tester Set the parameters Place the sample end for measurement CanNeed Instrument (HK) Ltd. www.canneed.com 2 ‘Tel: +86-758-2788469,2311786 FAX: +86-758-2782729, Email: info@canneed.com 18. CND_EMS 1.0 Software ‘Measure results and reports can be managed if software CND_EMS 1.0 has been installed. - Pl \=4) z = | CanNeed Instrument (HK) Lid. | www.canneed.com ‘Tel: +86-758-2788469,2311786 PAX: +86-758-2782729, Email: info@canneed.com CarNeed-EMS-200 Multiple Lid Measurement Station (CariNeed Instrument (HK) Ltd User Manual Ganneed_Ingtruneat Led www.canneed.com CariNeed-EMS-200 Multiple Lid Measurement Station CaniNeed Instrument (HK) Ltd User Manual Conneeg instraneat Lt www.canneed com CERTIFICATE OF QUALITY INSPECTION Wo cenity tat: Eng [>» f af [BTV EMS —200 Multiple Lid Measurement Station has been calibrated and verified as per our internal quality assurance standard. or end on bebal of EES NACo gra ued Director: PARRCES) ARIA Company stamp: wb Ld Date of inspection: — “Authorized Signature(s) CanNeed Instrument (HK) Ltd. | www.canneed.com cry Tel: +86-758-2788469,23 11786 FAX: +86-758-2782729, Email: info@canneed com

You might also like