Solution of Assignment-2: Answer: Explanation
Solution of Assignment-2: Answer: Explanation
Solution of Assignment-2: Answer: Explanation
Answer: Gateway
Answer: 255
3. The percentage of solar energy generated by India of the total global capacity till 2016
Answer: 3%
Explanation: Now, if you see where is India? Solar capacity 9.01 megawatt as far as the total
capacity is concerned. Here it is 3 percent of the total global capacity.
Answer: 10-13%
Explanation: Efficiency of the copper indium gallium selenide solar cell is 10-13%
5. Number of multi crystalline silicon solar cells are required to connected series to
produced open circuit voltage as 19 volt
Answer: 32
Explanation:
Output voltage of solar panel=Ns*Voc=19 volts
NS= Number of solar cell in series
each solar cell output voltage is Voc=0.6 volts
Ns=19/0.6=32
6. An array consists of the 10 solar modules in series and 5 modules in parallel each
model has the open circuit voltage 37.6 volts and short circuit current is 8.55 amper
than the maximum power of the array
Answer: 16074watts
Explanation:
The power output of the solar array is =Np*NS*Vm*Isc
=10*5*37.6*8.55
=16074watts
Np=Number of solar modules in series
NS= Number of solar modules in series
Vm=model open circuit voltage
Isc=model short circuit current
7. In the DFIG Tem>0 and s<0 than the mode of operation DFIG and speed of the
machine is
Explanation: if electromagnetic torque is greater than 0 (Tem>0 ) and the slip is less
than 0 and (s<0); that means, its operating in motoring mode, the mechanical speed is
greater than the synchronous speed
Answer:30%.
9. During the periods of extremely high winds and maintenance, which of the below is
(are) used to stop the wind turbine for the safety of the whole system?
Answer: Breaks
Answer: For a wind power generation system; cut in speed is defined as Speed below
which the turbine will not produce power.