Professional Documents
Culture Documents
Design Criteria-Of Platform at 144.045M LVL
Design Criteria-Of Platform at 144.045M LVL
ENGINEERING CONSULTANTS
DESIGN CALCULATION DOC No: PON8-AO-C-13465
P.O. BOX 7953.Dammam-31472 FOR PIPE SUPPORTING STRUCTURE CAL. BY: PFK
KSA. Tel.:8346778,Fax.8326594 AT SEA BULK LOADING FACILITIES REV : 00
TABLE OF CONTENTS
SECTION TITLE
IV DESIGN LOADS
VI REFERENCES
SAUDI DESIGNERS
ENGINEERING CONSULTANTS
DESIGN CALCULATION DOC No: PON8-AO-C-13465
P.O. BOX 7953.Dammam-31472 FOR PIPE SUPPORTING STRUCTURE CAL. BY: PFK
KSA. Tel.:8346778,Fax.8326594 AT SEA BULK LOADING FACILITIES REV : 00
1.1 A Supporting structure is to be provided for supporting the Pipes.The structure is being supported on the Existing Floor Beams
1.2 The structure will be analyzed and designed as steel space structure
consisting of steel posts,beams using STAAD Pro Software
SAUDI DESIGNERS
ENGINEERING CONSULTANTS
DESIGN CALCULATION DOC No: PON8-AO-C-13465
P.O. BOX 7953.Dammam-31472 FOR PIPE SUPPORTING STRUCTURE CAL. BY: PFK
KSA. Tel.:8346778,Fax.8326594 AT SEA BULK LOADING FACILITIES REV : 00
All structural steel design, fabrication and erection shall be performed in accordance with
the requirements of AISC Manual of Steel Construction and Specifications.
Shall conform to ASTM A36. Minimum yield strength shall be 250 Mpa,
2.3 Connections
Shall be welded connections. Welding electrodes shall be E7018 with a minimum tensile
strength of 485 Mpa (70 Ksi).
The allowable stresses for structural steel, high strength bolts and machine bolts
shall be in accordance with the requirements of AISC ASD manual of steel Construction
and specifications.
2.5.1 General
Maximum allowable deflection requirements for members shall be
in accordance with UBC-97 and as specified below:
IV-DESIGN LOAD
SAUDI DESIGNERS
ENGINEERING CONSULTANTS
DESIGN CALCULATION DOC No: PON8-AO-C-13465
P.O. BOX 7953.Dammam-31472 FOR PIPE SUPPORTING STRUCTURE CAL. BY: PFK
KSA. Tel.:8346778,Fax.8326594 AT SEA BULK LOADING FACILITIES REV : 00
4.1 General
All loads and forces used for design of this project shall be as defined in SES B01-E01,
1 21 [For 400mm Dia Pipe and 10m Long (Taken on conservative side)]
4.4.1 General
Wind loads shall be determined in accordance with SES B02-E03, ASCE-7
4.4.3 Exposure:
Exposure category C shall be used as per para 6.5.6.3,page no 25, ASCE 7-05
qz = 0.613*Kz*Kzt*V^2*I
qz = 1107.93N/m2
The design wind force (P) on the Structure shall be calculated as follows:
P =qz G Cf Af
P =1.107*1.7* Af Kn
Af= Projected Area normal to the wind except where Cf is specified for the actual surface area
The following wind load has been applied on the Structure by using STAAD Auto wind load generation commands.
SAUDI DESIGNERS
ENGINEERING CONSULTANTS
DESIGN CALCULATION DOC No: PON8-AO-C-13465
P.O. BOX 7953.Dammam-31472 FOR PIPE SUPPORTING STRUCTURE CAL. BY: PFK
KSA. Tel.:8346778,Fax.8326594 AT SEA BULK LOADING FACILITIES REV : 00
Loading
Loading Condition
Combinations
1 D+PL
2 D+WLX
3 D+WLZ
4 D+PL+0.75WLX
5 D+PL+0.75WLZ
Where:
D = Dead Loads
PL=Pipe Load
WLX =Wind Loads in X Direction
WLZ =Wind Loads in Z Direction
The Analysis and Design is done by STAAD PRO and for the Design Results Refer STAAD INPUT/OUTPUT
SAUDI DESIGNERS
ENGINEERING CONSULTANTS
DESIGN CALCULATION DOC No: PON8-AO-C-13465
P.O. BOX 7953.Dammam-31472 FOR PIPE SUPPORTING STRUCTURE CAL. BY: PFK
KSA. Tel.:8346778,Fax.8326594 AT SEA BULK LOADING FACILITIES REV : 00
6.0 REFERENCES
All structural design work shall be performed in accordance with the latest issue of the
following standards and specifications.
6.3 Softwares
V.Staad Input/Output
SAUDI DESIGNERS
ENGINEERING CONSULTANTS
DESIGN CALCULATION DOC No: PON8-AO-C-13465
P.O. BOX 7953.Dammam-31472 FOR PIPE SUPPORTING STRUCTURE CAL. BY: PFK
KSA. Tel.:8346778,Fax.8326594 AT SEA BULK LOADING FACILITIES REV : 00
VI.REFERENCES