MILL TEST CERTIFICATE

Certificate No.ACL/MTC/21-22/06 Dated: 14/04/2021

The following tests were conducted at our laboratory on & before 14Th Day of April 2021. Results are as
follows:

Material Description : HIGH ALUMINA CASTABLE


Material Brand : ACL-CAST-94G
Item Code as per Harmonized System : 69039040
Sample Drawn on : 25/03/2021
Sample Drawn by : SELF
Tested in Presence of : LAB IN-CHARGE

Typical SAMPLE Average Value


Type of Test Conducted Unit
Value No-1 No. 2 No.3 No.4 Obtained

Alumina (Al2O3) % 94.3 >94.3 >94.3 >94.3 >94.3 >94.3


Silica (SiO2) % 0.1 < 0.1 < 0.1 < 0.1 < 0.1 < 0.1
Iron (Fe2O3) % 0.3 <0.3 <0.3 <0.3 <0.3 <0.3
Calcium (CaO) % 5.0 ~ 5.0 ~ 5.0 ~ 5.0 ~ 5.0 ~ 5.0
Magnesia (MgO) % 0.10 <0.10 <0.10 <0.10 <0.10 <0.10
Alkalies (Na2+K2O) % 0.40 <0.4 <0.4 <0.4 <0.4 <0.4
Bulk Density @ 1050C Kg/m3 2660 >2660 >2660 >2660 >2660 >2660
Bulk Density @ 8150C Kg/m3 2690 >2690 >2690 >2690 >2690 >2690
0
Permanent Linear change @1095 C % +0.4 +0.4 +0.4 +0.4 +0.4 +0.4
0
Permanent Linear change @1370 C % -0.6 -0.6 -0.6 -0.6 -0.6 -0.6
0
Permanent Linear change @1595 C % -0.7 -0.7 -0.7 -0.7 -0.7 -0.7
Permanent Linear change @17600C % -0.5 -0.5 -0.5 -0.5 -0.5 -0.5
0
Modulus of Rupture @ 105 C MPa 11.7 ~ 11.7 ~ 11.7 ~ 11.7 ~ 11.7 ~ 11.7
Modulus of Rupture @ 8150C MPa 12.1 ~ 12.1 ~ 12.1 ~ 12.1 ~ 12.1 ~ 12.1
0
Modulus of Rupture @ 1095 C MPa 6.6 ~ 6.6 ~ 6.6 ~ 6.6 ~ 6.6 ~ 6.6
Modulus of Rupture @ 13700C MPa 10.4 ~ 10.4 ~ 10.4 ~ 10.4 ~ 10.4 ~ 10.4
Abrasion Loss @ 8160C CC 14 <14 <14 <14 <14 <14
Cold Crushing strength @ 1050C MPa 62.1 >62.1 >62.1 >62.1 >62.1 >62.1
Cold Crushing strength @ 8150C MPa 62.5 >62.5 >62.5 >62.5 >62.5 >62.5
Cold Crushing strength @ 10950C MPa 56.6 >56.6 >56.6 >56.6 >56.6 >56.6
0
Cold Crushing strength @ 1370 C MPa 67.8 >67.8 >67.8 >67.8 >67.8 >67.8
0
Service Temperature C 1870 >1870 >1870 >1870 >1870 >1870
Grain Size mm 5 <5% <5% <5% <5% <5%