Professional Documents
Culture Documents
Pub29 Spray Dryinginstantcoffeeproductatlowtemperatures
Pub29 Spray Dryinginstantcoffeeproductatlowtemperatures
Pub29 Spray Dryinginstantcoffeeproductatlowtemperatures
net/publication/266385918
CITATION READS
1 2,221
5 authors, including:
Denisley Bassoli
Starbucks Coffee Company
38 PUBLICATIONS 421 CITATIONS
SEE PROFILE
All content following this page was uploaded by Denisley Bassoli on 01 April 2015.
1 . INTRODUCTION
2.1 Materials
Figure 1 shows a flow-diagram of instant coffee product-
ion. A blend of Arabica (70%) and Robusta (30%) was
roasted, ground and extracted according to current indu-
strial standards. The resulting extract was divided into
two parts. One part was freeze concentrated (T.S. 30, 43
%) and spray dried at low temperature ( 1 20, 1 40, 160,or 18
448
Technologie
THERMAL
CONCENTRATION
LOW TEHPRATURE
SPRAY DRYING SYSTEM
FREEZE
CONCENTRATION
A. Analysis of aroma
B. Analysis of Density
449
With freeze concentration, viscosity rose as the level
of solids increased and the separability of ice particl-
es and extract decreased. As a result, the extent to
which solids could be concentrated was limited. Two
types of concentrate were examined by gas chromatography
with TENAX to compare the retention of aroma in each
type of concentrate. Figure 2 shows the retention of
aroma using the extract as an index (equal to 100%) .
Using the thermal concentration method the aroma retain-
ed was only 39%. That is, about 60% of the aroma was
lost in this process. With freeze concentration, in
contrast, 86% of the aroma was retained. The results
indicate that freeze concentration is an effective means
to reduce moisture content prior to the drying process.
Original extract
Freeze concentrated
extract (T.S. 30%)
Thermal concentrated
extract (T.S. 43%)
450
Technologie
60 r
o 40 -
20
10 20 30 40 50 60
Concentration (JS. Î5)
Freeze c o n c e n t r a t e d
extract ( T. S. 3 0 % )
Freeze c o n c e n t r a t e d
extract ( T. S. 4 3 % )
451
3.2.Comparison of Aroma Retention at Different Levels of
Concentration after Low Temperature Spray Drying
Freeze ccr.csn.traisi
extract
452
Technologie
Freeze concentrated
extract
Q_ 120°C
£
OJ
140'C
o 160°C
180'C
m o i s . 3°A
260 -
O N.
240 -
o \o
220 -
o
200 -
—•[ i ( I ¡ i •
c o- g a s
( I / k g — p o w d e r )
454
Technologie
0 20 40 60 80 100
L_ L_ i
Freeze
concentrated
extract
CO, gas
0 I /kg-powder
COi gas
2 I /kg-powder
CO2 gas
4 I /kg-powder
4 .Conclusions
1) W h e n e x t r a c t i o n of c o f f e e b e a n s is d o n e at l o w
temperature, with further processing by freeze concentr-
ation and low t e m p e r a t u r e spray d r y i n g , the resulting
coffee powder closely resembles the original extract.
2) P o w d e r o b t a i n e d by s p r a y d r y i n g at a h i g h e r concent-
r a t i o n of s o l i d s s h o w s b e t t e r a r o m a retention.
3) It is p o s s i b l e to c o n t r o l t h e d e n s i t y of c o f f e e
p o w d e r by t h e a d d i t i o n of CO2 to t h e e x t r a c t p r i o r to
low t e m p e r a t u r e s p r a y d r y i n g . T h e u s e of C O 2 h a s no
s i g n i f i c a n t i n f l u e n c e on a r o m a r e t e n t i o n of t h e c o f f e e .
455
References :
SUMMARY
456