Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

Agriculture Aquaculture Arts Food & Health Livestock Manufacturing Water &

Beverage Management Wastewater

Waterproof Pocket Water Quality Meters


TE R
ME S
MADE IN
2 YEAR J A PA N
AR
RA NT
Y
W

www.horiba-laqua.com
Pocket Ion, pH, and Conductivity Meters

Applications

Determination
of Nutrient
Concentrations in Soil
Solution and Tomato
pH and Plant Sap Conductivity and
Conductivity Fertigation management requires
rapid and accurate methods to
Elephant’s Foot
Measurements determine nutrient concentrations Testing
in Coconut Coir in soil solution and plant sap.
Substrate Folegatti et al (2005) found that the
concentrations of NO3-, K+, and Na+ Measurement of pH Elephant’s foot is a physiological
disorder in sweet pepper
Coconut coir testing involves
extracting a sample solution with
in soil solution and tomato plant
sap determined by LAQUAtwin
in Plant Tissue (Capsicum annuum L.), where the
base of the plant’s stem becomes
distilled water and measuring the ion pocket meters showed good An optimal pH value of 6.4 in plant swollen below the cotyledon level
pH and conductivity of the extract. correlations with those obtained tissue will encourage healthy and wounds develop at the base
The acceptable conductivity in soil solution and in leaf dry growth and prevent insects and of the stem’s epidermis because
ranges for 1:2 (v/v) dilution and matter, respectively, determined diseases attacking the plant. To of salt accumulation. LAQUAtwin
pour thru sampling methods are by standard methods in laboratory, measure pH, squeeze the sap conductivity meter can be
0.26-0.75 mS/cm Scan QR Code for link and concluded that Scan QR Code for link of mature leaves Scan QR Code for link used to measure Scan QR Code for link
and 1.0-2.6 mS/ LAQUAtwin ion with garlic press conductivity of soil
cm, respectively. pocket meters are and place the sap and help farmers
The ideal pH range useful low-cost onto the sensor choose the best
is 5.4-6.2 for both tools in fertigation of LAQUAtwin pH land to grow sweet
methods. management. meter. pepper crops.

Soil Nitrate
Measurement for Soil Salinity
Soil pH and Nutrient Impact of Soil
Determination of Measurement in
Availability Salinity on Sugar
Plant-Available Almond Orchard
The desirable soil pH range for
Nitrogen Cane Yield
optimum plant growth varies Crops have different levels of
among crops. Generally, soil pH tolerance to salinity. Testing soil Soil salinity adversely affects the
Nitrate concentration in soil is a salinity is the best way to check growth of sugar cane crops. To
6.0-7.5 is acceptable for most good indicator of available nitrogen
plants as most nutrients become soil condition in the orchard before help optimize sugar cane yield,
to plants. The required soil nitrate- salt damage occurs. The EC1:5 test check the sodium content in soil
available in this pH range. Soil pH nitrogen (NO3-N) for
can be determined Scan QR Code for link is used to estimate Scan QR Code for link by mixing it with Scan QR Code for link
specific crops varies Scan QR Code for link soil salinity (ECe). water in 1:5 ratio
by mixing soil from crop to crop
sample with water The soil salinity and measuring the
but in general, a threshold value for resulting solution
and then measuring concentration range
the resulting almond is 1.5 mS/ with LAQUAtwin
of 10-50 mg/kg is cm. sodium ion meter.
aqueous solution. desired.
| 01
Potassium
Determination in
Measurement of Plant Tissue
Comparison of LAQUAtwin
Potassium in Soil Potassium Ion Meter and ICP
Spectrometry Trials revealed
In laboratories, potassium in soil
close significant correlation (r Measurement of
Measurement of is extracted with 1M ammonium
values were 0.80 and 0.93 for first
acetate and analyzed with Atomic
and second trials, respectively) Potassium in Rice
Calcium in Soil Absorption (AA) or Inductivity
Coupled Plasma-Optical Emission between the LAQUAtwin potassium Potassium is one of the essential
Calcium is one of the essential Spectrometry (ICP-OES). ion meter readings and ICP results plant nutrients supplied via fertilizer
nutrients taken up by plants from LAQUAtwin potassium ion meter obtained from plant’s fresh petiole in most irrigated rice fields.
soil for cell wall development. To showed values higher than those sap and dried tissue, respectively. Extracting sap from the lower
measure calcium concentration in of ICP-OES. However, with 0.01M This suggested that LAQUAtwin stem of plant rice and analysing it
soil, extraction with 1M ammonium ammonium acetate extraction, potassium ion meter could be with LAQUAtwin potassium meter
acetate and filtration Scan QR Code for link good correlation Scan QR Code for link an appealing provide indication Scan QR Code for link
should be performed (r=0.981, r2=0.962) field method Scan QR Code for link of the current
prior to placing was obtained substitute for rapid potassium status
the filtrate onto between ICP-OES determination and help farmers
the flat sensor of and LAQUAtwin of potassium adjust the fertilizer
LAQUAtwin calcium potassium ion concentration in application.
ion meter. meter. plants.

Quick Nutrient pH and Conductivity


Analysis in Strawberry for Testing Acrylic
Rapid In-Field Production Paint Films and
Determination of Regular monitoring of nutrient levels Paper Supports
such as nitrate (NO3-), potassium and Formulating
Nitrogen in Onions (K+) and calcium (Ca 2+) in plant
Aqueous Cleaning
Nitrate Measurement petioles, soil solution, irrigation
Fresh root sap analysis with water, and drain water produces
Solutions
LAQUAtwin nitrate ion meter offers in Turf Grass not only good yield and fruit quality,
but also reduces fertilizer cost and Isotonic aqueous cleaning solutions
cost-effective, rapid, and easy that match the pH and conductivity
solution to determine nitrogen mitigates environmental hazards.
Nitrate concentration in grasses The LAQUAtwin pocket meters readings of acrylic paint films and
status in onion plants. The nitrate- can be used as an indicator of soil paper supports obtained from
nitrogen (NO3-N) concentrations are the perfect tools for testing
nitrogen (N) availability for their as they directly measure samples agarose gel pellets have been
in onion vary at different growth growth. Research at the University shown to be effective in reducing
stages. The Scan QR Code for link and provide results
of Connecticut Scan QR Code for link in just few seconds Scan QR Code for link or removing Scan QR Code for link
acceptable root sap suggests verdure dirt, dust, active
NO3-N concentration allowing growers
sap nitrate-N to identify and mold growth and
range for 0.5 to 1.5- concentrations at associated stains,
inch onion bulbs is correct any nutrient
200-300 ppm as the deficiency or excess tide line stains, and
350 to 500 ppm. optimum level. discoloration.
immediately.

02 |
Aquarium Water pH Measurement in
Testing the Acidification of pH Measurement to
Fermented Sausages Determine Freshness
Testing aquarium water such as pH of Brine for
freshwater and saltwater (either of Meat Products
natural or artificial seawater) with Lowering pH or increasing acidity Canned Food Testing
reliable instruments is necessary to of meat has become main hurdle Fresh meat must have a pH value
create a clean and safe environment against pathogenic bacteria in For brine of canned acid foods, in the range of 5.5 to 6.2 before
for your aquatic species. The sausage making. pH is used the equilibrium pH value must selling to consumers. LAQUAtwin
LAQUAtwin pocket Scan QR Code for link in the course of Scan QR Code for link be 4.6 or below to Scan QR Code for link pH meter provides Scan QR Code for link
meters require only fermentation process inhibit the growth a simple and cost
few drops of water in order to produce of Clostridium effective way to
and deliver the microbiologically botulinum, the most check the freshness
results in just few stable product that heat resistant of of meat in the local
seconds. has a pH value of 5.3 the food pathogen markets.
or less. microorganisms.

Determination of
pH Measurement Sodium Content in
to Determine pH Measurement of Food Samples Sodium Value Check
Acidification of Pickled Fruits and Foods contain varying amounts of for Canned Food
Sushi Rice Vegetables salt (NaCl), which has 40% sodium.
Determining the sodium content
There is a growing concern on
canned foods with large sodium
The rice used for sushi must be in foods accurately reduces the
Pickling is a process of preserving content as excessive intake of
acidified with acetic acid (vinegar) health risks associated with it.
fruits and vegetables in brine, oil, sodium can cause high blood
to pH less than 4.6 to inhibit the The American Heart Association
water or vinegar. The Australia pressure and hypertension. To
growth of pathogenic bacteria. To recommends consumption of less
New Zealand Food check the sodium content in canned
measure pH, simply Scan QR Code for link than 1500 mg/day
Standard Code Scan QR Code for link food, dilute a sample Scan QR Code for link
place a sample of sodium for most Scan QR Code for link
2.3.1 requires the with DI water in 1:5
rice mixture onto American adults,
preserved fruits and ratio, then place the
the flat sensor of which is the level
vegetables to have resulting solution
LAQUAtwin pH with the greatest
a pH not greater onto the LAQUAtwin
meter. effect on blood
than 4.6 to prevent sodium ion meter.
pressure.
botulism.

| 03
Nitrate Measurement
Measurement of Measurement of in Hybrid
Calcium in Milk and Sodium in Athlete’s Sudangrass and
Sweat Residual Sodium
Milk Beverages Pearl Millet Hays
Determining the calcium content Determining the sodium Determining the nitrate Check During Clean-
of milk and milk beverages helps concentration in sweat and
replacing that with proper
concentrations of sudangrass
and pearl millet before feeding
in-Place Process
consumers accurately gauge their
calcium intake. Unlike atomic electrolyte intake prevent fluid and them to livestock prevents nitrate Caustic soda or sodium hydroxide
absorption spectroscopy (AAS) electrolyte imbalances. Sweat can toxicity. Plant sap testing with (NaOH) is the chemical commonly
and inductively coupled plasma be easily extracted from sterile LAQUAtwin B-743 nitrate ion meter used in alkaline cleaning solution
atomic emission spectroscopy patches applied on skin and tested offers fast and accurate nitrate for clean-in-place (CIP) in process
(ICP), the LAQUAtwin calcium with LAQUAtwin sodium ion in-field analysis. Generally, the plants. Measuring the sodium ion
ion meter offers a meter. According maximum nitrate concentration on the
simpler method of
Scan QR Code for link to Gatorade Sports Scan QR Code for link c o n c e n t r a t i o n s Scan QR Code for link water rinse or swab Scan QR Code for link
measuring calcium Science Institute, considered safe for can indicate whether
ion-ionizing protein- the sodium results all cattle are 820 residual chemical
bound calcium in obtained with ppm and 700 ppm has been removed
sample using acid HORIBA falls within for sudangrass sap properly from the
before analysis. 15.4 mEq/L 95% of and pearl millet sap, process equipment.
the time. respectively.

pH of Cement for Measurement of Determination


Floor Installation Calcium in of Potassium
Testing Drinking Water
Measuring in Sea Water
Determining the calcium content
Fresh concrete is usually very of drinking water helps consumers Seawater has high ionic strength. To
alkaline, above pH 11. When the Salinity of Water accurately gauge their calcium eliminate matrix effect in measuring
alkalinity in a concrete subfloor intake. Unlike atomic absorption potassium (K+) concentration,
is high, it can stop the floor Measuring the salinity or the spectroscopy (AAS) and inductively standard solutions made with
covering adhesive from bonding dissolved salt content of water is coupled plasma atomic emission the same background as the
properly to the concrete. Australian important as aquatic organisms, spectroscopy (ICP), the LAQUAtwin seawater sample are recommended
Standard 1884 for resilient flooring livestock, and crops thrive at calcium ion meter offers a for calibration. The result of
installation states Scan QR Code for link different salinity Scan QR Code for link simpler method of Scan QR Code for link measurement using Scan QR Code for link
the the pH level of levels. Freshwater measuring calcium the LAQUAtwin
the concrete surface has a salinity value ion - ionizing bound Potassium Ion meter
should be between of less than 0.5 ppt calcium in water is within ±10% of
9 and 10 before while seawater has using acid before typical seawater
the flooring can be an average salinity analysis. concentration.
installed. of 35 ppt.

04 |
Compact Water Quality Meter
Lab in your pocket
LAQUAtwin compact meters
are simple and easy-to-use. Quick!
No container is Variety!
8 Water Quality Parameters: pH, needed to calibrate Measurements can
Conductivity, Total Dissolved Solids (TDS), or measure. Only few be made in different
drops of standards
Ions (Na+, K+, NO3-, Ca2+) and Salt and samples are all
positions because of
the sensor design.
Employing the same test principle as laboratory electrodes, LAQUAtwin you need.
compact meters provide a reliable and accurate measurement. Select
your meter that best suits your application from 11 colorful models.

Anyone! Wherever!
Easy & simple Solution! IP67 rated dust/
Discover more waterproof. Carry
operation
with easy, on-site LAQUAtwin and its
makes everyone
measurement. accessories in a
an expert.
carrying case.

Reliable! Cost effective


HORIBA 60 years 1/100 of standard
sensor technology solution and
distilled in HORIBA’s sample volume is
Accurate reading from a single drop of unique flat sensor. needed. Sensor is
sample in just a few seconds replaceable.
Incorporating the same parts as standard laboratory electrodes, the
LAQUAtwin compact meters are built with miniaturized components
and unique flat sensor chip, which is less than 1 mm thick—a result of Carrying case comes with calibration
60 years of HORIBA’s sensor engineering technology.
solutions and accessories
pH response membrane Everything you need for measurement is already packed in a carrying
KCI gel case for portability and storage. Also, you may attach a strap or tag
(not included) on the strap hole of the meter for your convenience.
Approx. 0.8 mm

Liquid junction Reference electrode Temperature sensor


Cross-sectional view of the flat pH sensor chip.

Calibrate and measure at the touch of a


button. Read the result when  appears.
Hassle-free operation with single-button calibration and measurement.
Record the reading once a smiley face appears on the display

Attach a strap or tag here.

Fully waterproof and dustproof (IP67


rated)1 with backlight display
The LAQUAtwin compact meters can be used anywhere and
anytime. No need to worry with water splashes or inclement
weather during measurement. With the meter’s backlight
display, you may view the reading in testing sites with poor
light condition.
Withstand immersion for 30 minutes at 1m depth. Not suitable for underwater use.
1

| 05
Easy measurement for all users
Sensor Measurement button
IP67 rated waterproof/dustproof. Press to view mV or temperature (Auto Stable mode)
Sensor is easily replaceable. or to lock / unlock reading (Auto Hold mode). Strap hole
In Set-up mode, press to scroll or adjust settings. You can attach a
strap or tag here.
Meter Power button
IP67 rated
Press to switch on or
waterproof/
off the meter or exit
dustproof.
set-up mode.

Calibration button
Sensor guard Press to perform
Protects sensor from damage calibration or save
and light. Sliding cap—for settings in set-up mode.
scooping water samples. Open
the whole sensor guard when
placing water or solid samples
directly onto the sensor.
Backlight
Open For easy viewing in the
dark. Flashes when
battery is low.
Close

Battery
Slide cap Indicator Stability mark
Appears when Lights up when
battery is low measurement
is complete.

Calibration mark Temperature alarm


Calibration is Flashes when the
complete when it temperature is out
stops flashing. of range.

Measurement mark Measurement value Voltage


Measurement is complete Flashes when the measurement measurement mode
when it stops flashing. value is out of the range. Displays sensor voltage.

Immersion Scoop
When you're in the lab, you Use as a scoop to test
can test the sample in a water from a river. Vertical
beaker. Ensure the sensor scoop is available with a
guard sliding cap is open. unique sensor guard.

Drops Wipe
Drop a sample with a Unique measurement The sampling sheet allows
dropper; small volumes as options with tiny, trace volumes to be
0.1 mL can be measured. analysed. For example,
Using sampling sheet B,
LAQUAtwin wipe off the surface of the
volumes down to 0.05 mL One meter provides seven flexible skin with a sampling sheet
can be tested. measurement techniques. Simply soaked with pure water
and measure.
choose the method that best fits
your sample and situation.

Solid samples Paper, textiles


Foods containing some
moisture can be tested by
and films
placing a small piece directly To test sheets of paper and
onto the sensor. textiles, cut up the sample
into small pieces and place
them directly onto the sensor
then add a defined amount of
Powders pure water.
LAQUAtwin meters can also test dry powders.
Simply place the powder sample onto the sensor, All methods applicable to pH measurement. Conductivity models cannot be tested with
and add an appropriate amount of pure water. solids, powders, and sheet-like samples. Above pictures are for illustration purposes only.

06 |
pH

Model pH-11 mV pH-22 mV pH-33 mV Temp

WATER MICRO 2 PT 0.1 pH WATER MICRO 3 PT 0.01 pH WATER MICRO 5 PT 0.01 pH


Features PROOF VOLUME CAL PROOF VOLUME CAL PROOF VOLUME CAL

Part No. 3999960122 3999960123 3999960124


Measurement
Glass Electrode
Principle
Minimum
Sample 0.1 ml (0.05 ml with Sampling Sheet B)
Volume
pH Range /
0.0 to 14.0 pH / 0.1 pH 0.00 to 14.00 pH / 0.01 pH
Resolution
Accuracy ± 0.1 pH ± 0.01 pH
Maximum pH
Calibration 2 3 5
Points
pH Calibration USA: 1.68, 4.01, 7.00, 10.01 & 12.46
Curves NIST: 1.68, 4.01, 6.86, 9.18 & 12.46
mV Range /
± 650 mV / 1 mV
Resolution
Temperature
Display / ­— 0 to 50.0 ºC / 0.1 ºC
Resolution
Automatic Buffer Recognition • Temperature Compensation • Temperature Calibration* •
Functions Auto Hold / Auto Stable • Automatic Power Off (30 mins.) • Low Battery Indicator •
IP67 Water / Dust Proof • Replaceable Sensor
Display Custom (Monochrome) Digital LCD with Backlight
Operating
Temperature / 5 to 40 ºC / 85% or less in relative humidity (no condensation)
Humidity
Battery Life Approx. 400 hrs. continuous use without backlight
Material ABS epoxy body / flat glass sensor
Dimensions 164 x 29 x 20 mm(excluding projections)
Mass Approx. 55g (including sensor and batteries)
Accessories pH 7.00 & 4.01 pH Buffers (14 ml each)
included CR2032 Batteries (2) • Dropper • Instruction & Quick Manuals • Storage Case
*Applicable for models with temperature display

| 07
Conductivity (EC) Salt (NaCl)

Model EC-11 EC-22 Temp


EC-33 TDS Temp
Salt-11 Temp

WATER MICRO 2 PT ~19.9 WATER MICRO 3 PT ~199.9 WATER MICRO 3 PT ~199.9 WATER MICRO 2 PT EC
Features PROOF VOLUME CAL mS/com PROOF VOLUME CAL mS/com PROOF VOLUME CAL mS/com PROOF VOLUME CAL CONV

Part No. 3999960125 3999960126 3999960127 3999960128


Measurement
2 Electrode Bipolar AC
Principle
Minimum
Sample 0.12 ml
Volume
Conductivity
Conductivity
0 to 199 µS/cm (1 µS/cm) Salt
0 to 199 µS/cm (1 µS/cm)
200 to 1999 µS/cm (1 µS/cm) 0.0 to 100.0 g/L (0.1 g/L)
200 to 1999 µS/cm (1 µS/cm)
Measurement 2.00 to 19.99 mS/cm (0.01 mS/cm)
2.00 to 19.99 mS/cm(0.01 mS/cm)
Range / 20.0 to 199.9 mS/cm (0.1 mS/cm)
Resolution TDS
0.0 to 99.9 ppm (0.1 ppm) Salt
­—­
100 to 999 ppm (1 ppm) 0.00 to 10.00 % (0.01 %)
1000 to 9990 ppm (10 ppm)
Accuracy ± 2% full scale (for each range) ± 10% of actual value
Maximum
Calibration 2 3 2
Points
1413 µS/cm, 12.88 mS/cm 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm
Calibration
TDS Factor (0.4 to 1.0) / NaCl / Sea water
Curves ­—
EN 27888 / 442 / NaCl
Temperature
Display / — 0 to 50.0 ºC (0.1 ºC)
Resolution
Automatic Range • Automatic Standard Recognition • Temperature Compensation (2%/ºC fixed) • Temperature Calibration*
Functions
• Auto Hold / Auto Stable • Automatic Power Off (30 mins.) • Low Battery Indicator • IP67 Water / Dust Proof • Replaceable Sensor
Display Custom (monochrome) digital LCD with backlight
Operating
Temperature 5 to 40 ºC, 85% or less in relative humidity (no condensation)
& Humidity
Battery Life Approx. 400 hrs. continuous use without backlight
Material ABS epoxy body / Titanium coated with platinum black sensor
Dimensions 164 x 29 x 20 mm(excluding projections)
Mass Approx. 50g (including sensor and batteries)
0.5% & 5.0% NaCl Standard
Accessories 1413 µS/cm & 12.88 mS/cm Conductivity Standard Solutions (14 ml each)
Solutions (14 ml each)
included
Conditioning Solution (4 ml) • CR2032 Batteries (2) • Dropper • Instruction & Quick Manuals • Storage Case
*Applicable for models with temperature display
TDS Calibration Curves
Application Key chemical species TDS selection
Aquaculture, pickling NaCl NaCl
Boiler water, HVAC Na2SO4, NaHCO3, NaCl 442
Environmental EN standard for environmental water EN 27888
TDS Factor Linear Default: 0.5
General application KCl Selectable: 0.4 to 1.0
EN 27888 Curve 442 Curve NaCl Curve
12000 90000 300

80000
10000 250
70000

8000 200
TDS (mg/L)

COND / mS/cm-1

60000
TDS442 / ppm

6000 50000 150

40000
4000 100
30000

2000 20000
50

0 10000 0
0 5 10 15 20 25 0 1000 2000 3000 4000 5000 6000
0
Conductivity (mS/cm) 0 20000 40000 60000 80000 100000 NaCl / mM
Conductivity µS/cm 08 |
Salt (NaCl) Sodium Ion (Na+) Potassium Ion (K+) Nitrate Ion (NO3 -) Calcium Ion (Ca2+)

Model Salt-22 Temp


Na-11 Temp
K-11 Temp
NO3-11 Temp
Ca-11 Temp

WATER MICRO 2 PT WATER MICRO 2 PT WATER MICRO 2 PT WATER MICRO 2 PT WATER MICRO 2 PT
Features PROOF VOLUME CAL PROOF VOLUME CAL PROOF VOLUME CAL PROOF VOLUME CAL PROOF VOLUME CAL

Part No. 3200689158 3200689159 3200689160 3200689162 3200689161


Measurement
Ion Selective Electrode
Principle
Minimum
0.3 ml (0.05 ml with Sampling Sheet B)
Sample Volume
NO3-: 6 to 9900 ppm
4 to 9900 ppm (mg/L)
(mg/L)
Measurement 2 to 9900 ppm (mg/L) (0.1 to 250 mmol/L) 4 to 9900 ppm (mg/L)
0.1 to 10% by weight (0.1 to 160 mmol/L)
Range (0.1 to 430 mmol/L) 2 to 5000 kg/10a (soil/ (0.1 to 250 mmol/L)
NO3-N: 1.4 to 2200 ppm
water ratio 1:5)
(mg/L)
0 to 99 ppm: 1 ppm
0.00 to 0.99%: 0.01%
Resolution 100 to 990 ppm: 10 ppm
1.0 to 9.9%: 0.1%
1000 to 9900 ppm: 100 ppm
Accuracy ± 10% of actual value ± 20% of actual value
Maximum
Calibration 2
Points
Temperature
Display / 0 to 50.0 ºC / 0.1 ºC
Resolution
Automatic Standard Recognition • Changeable Low and High Calibration Values • Temperature Compensation
Functions • Temperature Calibration • Multiplication Compensation (0.01 to 9.90) • Auto Hold / Auto Stable
• Automatic Power Off (30 mins.) • Low Battery Indicator • IP67 Water / Dust Proof • Replaceable Sensor
Display Custom (Monochrome) Digital LCD with Backlight
Operating
Temperature / 5 to 40 ºC / 85% or less in relative humidity (no condensation)
Humidity
Battery Life Approx. 400 hrs. continuous use without backlight
Material ABS epoxy body / flat glass sensor
Dimensions 164 x 29 x 20 mm (excluding projections)
Mass Approx. 55g (including sensor and batteries)
Accessories 150 & 2000 ppm Standard Solutions (14 ml each) • Sampling Sheet B (5pcs)
included CR2032 Batteries (2) • Dropper • Instruction & Quick Manuals • Storage Case

Correlation between LAQUAtwin measurement data and ion chromatography


Crops (NO3-) Isotonic drink, mineral water drinks and
mineral water (Na+, K+, Ca2+)
10000
Spinach, 1000
Komatsuna,
Cabbage,
Measurement data of

Measurement data of

Bok choy,
LAQUAtwin (ppm)

LAQUAtwin (ppm)

Napa cabbage,
Lettuce,
1000 Other
100

Na+ : y=1.127x R 2 =0.941


y = 0.988 x Ca2+: y=0.922x R 2 =0.990
R2 =0.937 K + : y=0.906x R 2=0.954

100 10
100 1000 10000 10 100 1000

Measurement data of ion chromotography (ppm) Measurement data of ion chromotography (ppm)
*When measuring Ca 2+, samples are pretreated in order to match the conditions of the ion chromatography.
| 09
Solutions & Accessories
LAQUAtwin Replacement Sensors
Part No. Model Description
3200459834 S010 pH Sensor (for B-711, B-712, B-713, pH-11, pH-22 & pH-33)
3200459866 S021 Salt Sensor (for B-721 & Salt-22)
3200459867 S022 Sodium Ion Sensor (for B-722 & Na-11)
3200459868 S030 Potassium Ion Sensor (for B-731 & K-11)
3200459870 S040 Nitrate Ion Sensor (for B-741, B-742, B-743, NO3-11, NO3-11C & NO3-11S)
LAQUAtwin
3200459869 S050 Calcium Ion Sensor (for B-751 & Ca-11) Replacement Sensors
3200459672 S070 Conductivity Sensor (for B-771, EC-11, EC-22, & EC-33)
3200597237 S071 Salt EC Sensor (for Salt-11)

LAQUAtwin Standard Solutions (6 x 14ml bottles per pack)


Part No. Model Description
5505293441 USA-2 Buffers, pH 4/7, Model B-713, pH-11
5505293442 USA-3 Buffers, pH 4/7/10, Model pH-22
pH Buffers Conductivity NaCl
5505293443 USA-5 Buffers, pH 1.68/4/7/10/12.5, Model pH-33 Standard Standard
3999960110 514-22 1413 µS/cm Conductivity Standard Solution (for B-771, EC-11, EC-22, EC-33) Solutions Solutions
3999960111 514-23 12.9 Conductivity Standard Solution (for B-771, EC-11, EC-22, EC-33)
3999960112 514-05 0.5% NaCl Standard Solution (for Salt-11 & Salt-22)
3999960113 514-50 5.0% NaCl Standard Solution (for Salt-11 & Salt-22)
3999960114 514-20 Conditioning Solution (For Conductivity & Salt Sensors)
3200457723 Y022H 2000ppm Sodium Ion Standard Solution (for B-722 & Na-11)
3200457724 Y022L 150ppm Sodium Ion Standard Solution (for B-722 & Na-11) Sodium Ion Potassium Calcium Ion
Standard Ion Standard Standard
3200457719 Y031H 2000ppm Potassium Ion Standard Solution (for B-731 & K-11) Solutions Solutions Solutions
3200457720 Y031L 150ppm Potassium Ion Standard Solution (for B-731 & K-11)
3200053433 Y041 5000ppm Nitrate Ion Standard Solution (for N03-11C)
3200053514 Y042 300ppm Nitrate Ion Standard Solution (for N03-11C & N03-11S)
3200053532 Y043 2000ppm Nitrate Ion Standard Solution (for B-743 & N03-11)
3200053535 Y044 30ppm Nitrate Ion Standard Solution (for N03-11S)
3200053536 Y045 150ppm Nitrate Ion Standard Solution (for B-743 & N03-11)
Nitrate Ion
3200457727 Y051H 2000ppm Calcium Ion Standard Solution (for B-751 & Ca-11) Standard Solutions
3200457728 Y051L 150ppm Calcium Ion Standard Solution (for B-751 & Ca-11)

LAQUAtwin Accessories
Part No. Model Description
3200053858 Y046 Sampling Sheet B (100pcs) for minute samples (≥ 0.05ml)
3200459736 Y048 Sampling Sheet Holder (use with sampling sheet B for samples with particulates)
Sampling Sheet B
Nitrate Ion Meter for crop N03-11C Nitrate Ion Meter for soil N03-11S
(Part No. 3200689163) (Part No. 3200689164)

Accessories included: Accessories included:


Standard solution for crops (300ppm & Standard solution for soil (30ppm, 300ppm)
5000ppm) (14mL), 2 CR2032 batteries, (14mL), 2 CR2032 batteries, Instruction
Instruction manual, 5 Pipettes, Cleaning manual, 5 Pipettes, Cleaning solution bottle
solution bottle (250mL), Crop sample (250mL), 3 Extraction bottles (100mL), 2
press, 3 Medical cups, Quick manual, sets of spoons for soil sampling, Tweezers,
Carrying case Sampling sheetB, 2 Sampling sheet holders,
Quick manual, Carrying case
10 |
Visit HORIBA’s website!
Water Quality Analyzers www.horiba-laqua.com

With over 60 years of engineering excellence,


HORIBA's diverse range of water quality
analyzers and electrodes are ideal for
everyday laboratory needs through to the
most demanding of applications. Visit our
website for a wealth of useful information and
water quality measurement tips to help you
obtain the best results in your work.

Benchtop Meters
Developed using extensive feedback from
users, our new LAQUA meters deliver the
best solution for water quality analysis. Our
LAQUA website features an online 'Selection
Guide' to enable you to find the perfect
LAQUA meter and electrode for your need.

Handheld Meters
In the lab, in the field or anywhere you need
it. LAQUA Handheld meters are designed
for use with one hand and with an IP67
waterproof rating and shock-resistant casing.
Meters can be used for long periods, even
in dark places, making it ideal for field
measurements in rivers and lakes.

Electrodes Application Notes


Various electrodes to match any application. LAQUAtwin pocket meters offer quick
A wide range of products for both benchtop and convenient alternative to analyze
and portable systems are available, important parameters with high accuracy.
including easy and reliable standard models, Several application notes are available at
application-focused models for small samples (http://goo.gl/znwE6j) detailing the use of
or large containers, and special electrodes LAQUAtwin and the results achieved for the
for specific sample characteristics. respective applications. Additional application
notes will be added when available.

SUPPORT HORIBA CUSTOMER SUPPORT SYSTEM


HORIBA offers a variety of services to help you conform to quality standards and international guidelines such as GLP, GMP and ISO.
Technical Support User Support Validation Support
Please contact us with any technical Our support website is available for Please contact us with any questions or
questions about our products. registered customers and features: requirements for your validation procedure.
• Data collection software • Traceability certification*
• IQ/OQ/PQ support*
• Instruction manual downloads • SOP guidance
• Measurement tips, etc. • FAQ
www.horiba.com/wq/support www.horiba.co.jp/register *Optional services

Please read the operation manual before using this product to assure safe and proper handling of the product.

• The contents of this catalog are subject to change without prior notice, and without any subsequent liability to this company.
• The color of the actual products may differ from the color pictured in this catalog due to printing limitations.
• It is strictly forbidden to copy the content of this catalog in part or in full.
• All brand names, product names and service names in this catalog are trademarks or registered trademarks of their respective companies.
• Windows is a registered trademark of Microsoft Corporation in the United States and other countries.
• Complies with all ACMA RCM compliance requirements EMC Systems Doc Number: C160104-2

http://www.horiba.com e-mail: labinfo@horiba.com


HORIBA Instruments Incorporation Distributed by: ABQ Industrial LP USA
9755 Research Drive Tel: +1 (281) 516-9292 / (888) 275-5772 eFax: +1 (866) 234-0451
Web: https://www.abqindustrial.net E-mail: info@abqindustrial.net
Irvine, CA 92618 U.S.A.
Tel: +1 (949) 250-4811
Fax: + 1 (949) 250-0924 Brochure PBT-EN-03-2018B

You might also like