Factored load on the column Pu = 1198 kN

2
Safe bearing capacity of soil SBC = 250 kN/m
Grade of concrete fck = 20 N/mm2
2
Grade of steel fy = 500 N/mm
Size of column
b = 380 mm
D = 450 mm
2
Area of footing A = 3.2 m
Footing dimensions l = 1.80 m
b = 1.80 m
2
Ultimate pressure below foundation = 369.8 kN/m

Depth for Punching shear


2
Design shear strength tc = 1.12 N/mm
2
Actual punching shear eqn. = d d const
-0.4 -306.90 1134772.2

2
Allowable punching shear eqn. = d d const
4.5 1855.9 0
Depth required for punching shear d = 309.8 mm

Depth for Bending moment


BM about minor axis of column mu = 93.2 kN.m
Depth required for bending moment d = 183.2 mm
Depth taken for iteration calculations D = 375.0 mm

Depth for one-way shear


Iterated Percentage of steel pt = 0.12 %
Design shear strength tc = 0.26 N/mm2
Depth required for One way shear d = 394.7 mm
D = 450.0 mm
Governing depth of footing D = 475 mm

Size of footing to provide = 1.8m x 1.8m x 0.475m


Area of steel calculation Ast2 Ast Const
10.9 -184875 93196265
2
Ast = 936 mm

Size of footing to provide = 1.8m x 1.8m x 0.475m

Reinforcement to provide = Dia no. bar Spacing c/c


10.0 12 140.00 mm
12.0 9 185.00 mm
16.0 5 340.00 mm
20.0 3 565.00 mm
Area of steel calculation Ast2 Ast Const
10.9 -141375 93196265
Ast = 1253.8 mm2
Percentage of steel %Ast = 0.21

Iteration I
Check the depth for one-way shear
Percentage of steel pt = 0.21 %
2
Design shear strength tc = 0.3 N/mm
Depth required for One way shear d = 353.6 mm
D = 425.0 mm
Governing depth of footing D = 425.0 mm

Governing depth of footing D = 450.0 mm

Area of steel calculation Ast2 Ast Const


10.9 -174000 93196265
Ast = 998.7 mm2

Percentage of steel %Ast = 0.14

Iteration II
Check the depth for one-way shear
Percentage of steel pt = 0.14 %
2
Design shear strength tc = 0.3 N/mm
Depth required for One way shear d = 385.5 mm
D = 450.0 mm
Governing depth of footing D = 450.0 mm

Governing depth of footing D = 475.0 mm

Area of steel calculation Ast2 Ast Const


10.9 -184875 93196265
Ast = 936.0 mm2

Percentage of steel %Ast = 0.12

Iteration III
Check the depth for one-way shear
Percentage of steel pt = 0.12 %
2
Design shear strength tc = 0.3 N/mm
Depth required for One way shear d = 394.7 mm
D = 450.0 mm
Governing depth of footing D = 475.0 mm
Governing depth of footing D = 475.0 mm

Area of steel calculation Ast2 Ast Const


10.9 -184875 93196265
Ast = 936.0 mm2

Percentage of steel %Ast = 0.12

Iteration Iv
Check the depth for one-way shear
Percentage of steel pt = 0.1 %
2
Design shear strength tc = 0.3 N/mm
Depth required for One way shear d = 394.7 mm
D = 450.0 mm
Governing depth of footing D = 475.0 mm

Governing depth of footing D = 475.0 mm

Area of steel calculation Ast2 Ast Const


10.9 -184875 93196265
Ast = 936.0 mm2

Percentage of steel %Ast = 0.12

Iteration V
Check the depth for one-way shear
Percentage of steel pt = 0.12 %
2
Design shear strength tc = 0.3 N/mm
Depth required for One way shear d = 394.7 mm
D = 450.0 mm
Governing depth of footing D = 475.0 mm

Governing depth of footing D = 475.0 mm

Area of steel calculation Ast2 Ast Const


10.9 -184875 93196265
Ast = 936.0 mm2

Percentage of steel %Ast = 0.12