Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

4/16/2019 11:06:54 AM

KEY PLAN :

3
E
AS
PH

2D
E
AS
PH
SHAPED EXPANSION CONCRETE CLASS "A" SE
2C

150 WIDE PROTECTIVE 18 JOINT KILLER PH


A
02
S-
WARNING TAPE (DETAIL-709) 2B
-O

1 2B
E E
AS AS
PH PH

150
GROUND LEVEL
2A
E
NORTH PH
AS

600
QIBLA

D
FLOW NOTES :
W=1.5 D+500
SELECTED FILL MATERIAL 1.THIS DRAWING IS NOT TO BE SCALED.
750 MIN. COMPACTED AS SPECIFIED 2.REFER TO RELEVANT SURVEY, STRUCTURAL, MECHANICAL, ELECTRICAL,
150 MIN. THICKNESS

VARIES
LANDSCAPE, ETC. CONSULTANT DRAWINGS & SPECIFICATIONS BEFORE

Y
UNDER BARREL BOTTOM
PROCEEDING WITH THE WORK.
3.DETAIL DRAWINGS SHOWN ARE INDICATIVE OF DESIGN INTENT. CONTRACTOR
TO SUBMIT SHOP DRAWINGS AND SAMPLE PER SPECIFICATIONS TO
DESIGNER'S APPROVAL PRIOR TO CONSTRUCTION OR FABRICATION.
CONCRETE PIPE
W/2 PRECAST SUPPORT 4.CONSTRUCTION MUST CONFORM TO ALL APPLICABLE CODES AND
CONCRETE SURROUND TO PIPES WITH COUPLINGS REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION.
5.THE CONTRACTOR WORKING FROM DRAWINGS NOT SPECIFICALLY MARKED
LINE OF NARROW TRENCH LIMIT
"FOR CONSTRUCTION" MUST ASSUME FULL RESPONSIBILITY AND BEAR COSTS
150 FOR ANY CORRECTIONS OR DAMAGES RESULTING FROM THIS WORK.
D 6.THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS PROVIDED BY AND IS THE
300

SURFACE MAY BE FORMED TO


PROPERTY OF THE ARCHITECT.
HORIZONTAL RADUIS OR BATTER 7.THE CONTRACTOR SHALL VERIFY THE CONTENT OF THIS DRAWING AND SHALL
NOTIFY THE CONSULTANTS OF ANY DEVIATION OR DISCREPANCY.
8.CORRECTNESS, BUILDABILITY AND STABILITY OF THE CONSTRUCTION SHALL
REMAIN SOLE RESPONSIBILITY OF THE CONTRACTOR.

CONCRETE CLASS "A"

150 MIN. THICKNESS UNDER

Y
BARREL BOTTOM

UNDISTURBED MATERIAL
W(TRENCH WIDTH) X Y

FLEXIBLE JOINTS
CONCRETE BED AND SURROUND TO PIPES

NOTE:
CONCRETE SURROUND TO BE INCLUDED
WHERE SPECIFIED OR INSTRUCTED BY
THE ENGINEER.
GRAVEL BEDDING
AS SPECIFIED. REVISIONS :
REV. DATE DESCRIPTION
T0 11.12.2019 ISSUED FOR TENDER
MASS CONCRETE
CLASS "C"

GRIT BONDING TO PIPE


EMBEDED IN CONCRETE (uPVC & GRP)

DIMENSIONS OF X & Y PROJECT TITLE :

Y Y
PIPE DIA. X
MIN. MAX. ARABIAN RANCHES III
UP TO 300 150 450 2.5D
PHASE 2A
PROTECTION SLAB WIDTH (PSW) > 300 TO 1000 300 1.5D 2.5D

1.5 D+500 > 1000 450 1.5D 2.5D


CLIENT / DEVELOPER :
750 (MIN.)

PIPE CONNECTION AT STRUCTURES


150

400 D 400
150

LEAD CONSULTANT :

150 WIDE PROTECTIVE


WARNING TAPE (DETAIL-709)

GEOTEXTILE EXTRA TRENCH WIDTH GROUND LEVEL


REQUIRED IF SHEETING
IS USED

600
TRENCH CROSS-SECTION CONSULTANT :
TO BE AGREED WITH THE
ENGINEER.
W=1.5 D+500
SELECTED FILL MATERIAL
750 MIN. THOROUGHLY COMPACTED

VARIES
AS SPECIFIED.

PROTECTION SLAB TO PIPES


W/2
NOTE:
1. PROTECTION SLAB INCLUDED AS SPECIFIED
STANDARD TRENCH D GRANULAR SURROUND TO
ISSUE STATUS :
300

OR INSTRUCTED BY THE ENGINEER. WIDTH TO EXTEND 300mm EXTEND 300mm ABOVE


ABOVE PIPE CROWN. THE CROWN OF uPVC PIPES ISSUED FOR TENDER
2. CONCRETE AND 150mm ABOVE THE
CROWN OF AC PIPES.
SCALE : NTS DRAWN BY : A.L
CLASS "A" GEOTEXTILE AS SPECIFIED
100 MIN. THICKNESS
3. REINFORCEMENT UNDER SOCKET DATE : 11.12.2019 REVIEWED BY : D.A
C:\Users\mary\Documents\08_Revit Local Files 2018\UA18120-A-B-4P3_mary.rvt

USE 010 @ 200 C/C IN BOTH DIRCETIONS FOR D< 350mm, Y= 150 MIN. TITLE :

Y
GRADE 460-BS4449 COMPACTED GRANULAR D> 350mm, Y= 200 MIN.
MATERIAL AGAINST
EPOXY COATED UNDISTURBED GROUND TYPICAL DETAIL # 07
TRENCH SHEETS TO BE (STORM SEWER DETAILS)
4. FLEXIBLE JOINTS REMOVED PROGRESSIVELY
AS BEDDING AND BACKFILL UNDISTURBED MATERIAL
POSITION ABOVE EACH PIPE JOINT INCLUDING IS PLACED AND COMPLETED.
W(TRENCH WIDTH)
20mm EXPANSION JOINT FILLER. DRAWING NO. REV NO.

18120-M-P2A-SW-5007 T0
STORM WATER DRAINAGE PIPE INSTALLATION
THIS DRAWING, THE DESIGNS AND DETAILS SHOWN ARE THE COPYRIGHT OF
U+A ARCHITECTS AND SHALL NOT BE COPIED OR REPRODUCED IN ANY
FORM WITHOUT THEIR WRITTEN CONSENT

© U+A ARCHITECTS

You might also like