ACCEPTANCE TEST DATA

UPGRADE CAPACITY by Hardware


MICROWAVE RADIO SYSTEM
MPR 9500

STATION A : 130153_SAMBIREJO
GAMPENGREJO KEDIRI
STATION B : 130151_YONIF 521 KEDIRI
PROJECT : NEW ALU
WPO No. : 2015 NEFPA/PO/08082018/0574-a
ATP DATE :

Provided by: ___________________ Date:___________________


Approved by: ___________________ Date:___________________
s

9500 MPR
SITE ACCEPTANCE TEST RESULT SHEET

Site ID / Site Name 130153_ SAMBIREJO GAMPENGREJO KEDIRI


130151_130153 / YONIF 521 KEDIRI_SAMBIREJO GAMPENGREJO
Link / Direction Name KEDIRI

Equipment Type  MSS4  MSS8  MSS-1  SA

 New Link  Parallel Link  Swap Existing


Configuration Type
 Others (Pls specify : )

Acceptance Date

Nokia Representative Managed Services

Name : Name :
Date : Date :
Signature : Signature :

BMG H3I Representative

Name : Name :
Date : Date :
Signature : Signature :

Acceptance Category*

 Accepted  Conditionally Accepted  Not Accepted

 If conditionally accepted or not accepted, the action required to achieve acceptance must be
detailed write down.

REMARKS :
I. PRELIMINARY CHECK
 Site Electrical / Mechanical Check
ITEM TO BE CHECKED STATUS Remark
Electrical Supply  OK  NOK  NA
Site / Tower Grounding  OK  NOK  NA
Site left clean & tidy  OK  NOK  NA
Shelter Type  Shelter (Indoor)  Shelter Less (Outdoor)
Outdoor Shelter’s FAN is working normally (*)  OK  NOK  NA
* For site shelter less only

II. INDOOR UNIT CHECK LIST


Tabel 1. Vinput MW Specification
Nominal Voltage Spec
Input MW (VDC)

Table 2
VDC Supply
Test Item Remark
(-24 VDC / -48VDC)
Input DC power MW
By Switch off the DC breaker at DCPDB or
Power Redundancy test  OK  NOK  NA rectifier. Label must be attached

 Installation & Mechanical Check


ITEM TO BE CHECKED STATUS Remark

Installation & label of IDU  OK  NOK  NA


Installation & label of DDF  OK  NOK  NA
Installation & label of DCPDB  OK  NOK  NA
Installation & label of Feeder / Coaxial &
 OK  NOK  NA
Optical cable
The equipment is correctly grounded  OK  NOK  NA
Lightning surge suppressor (indoor)  OK  NOK  NA
NE System Setting & Configuration
 Software Release :  R6.x  R7.x  Other ( ……… )

 Software / RMU License Serial Number : 5DSBN1BN10707F958330


Software License
 Software License String :
R/8Cap040/4Cap220/4modAdp/PTB/4XPIC/1588TC
Payload Capacity check (Modem
 OK  NOK Pls specify Net Radio Cap : 160.702 (Mbps)
Profile)
E1 Tributary Installed Capacity  32E1  64E1  NA
QoS Classification  802.1D  802.1Q  802.1ad
 DHCP Server Eth
 LOS Criteria  Enabled  Disabled
 Static LAG Criteria
NE MAC Address 00:21:ae:03:c4:d2
Power Source for ODU MPT  QMA  PFoE  External Power Injector
IDU-ODU Data cable interface  Optical  Electrical / Ethernet  NA
Installation of Eth traffic & protection
cable to Existing MSS (core Main &  OK  NOK  NA
core Stby) if any

Synchronization
Clock Synchronization Role  Master  Slave

Restoration Criteria  Revertive  Non Revertive

Primary  Free Run Osc.  E1/T1 (Port Nbr …….)  Sync-In Port  Radio Port  Sync-E
Clock Source
Secondary  Free Run Osc.  E1/T1 (Port Nbr …….)  Sync-In Port  Radio Port  Sync-E

Installation of Synchronization Cable  OK  NOK  NA

Loopback Check
MEASUREMENT Refer to
ATP
ITEM TEST SPECIFICATION
Main Standby Paragraph

Internal (Core
 OK  NOK NA
Facing) Loopback Working
For MSS1/4/8
Normally
4.20
External (Radio
 OK  NOK NA
Facing) Loopback
Line Side Loopback  OK  NOK NA
Working
For MSS-1c Radio Side Normally
4.20
 OK  NOK NA
Loopback
Indoor Equipment Composition & Alarm Status

Slot
No.
Module / Card Type Part Number Serial Number Alarm Status
1 MSS-8 3DB18485EAAA01 VG182090070  OK  NOK NA
2 MSS/CORE-MAIN 3DB19318BAAA01 TH1827Q013J  OK  NOK NA
3 MSS/EASv2 3DB19017ABAF01 TH1828Q038W  OK  NOK NA
4 MSS/EASv2 3DB19017ABAF01 TH1828Q0360  OK  NOK NA
5 MSS/E1 3DB18126AEAD02 TH1803Q00TN  OK  NOK NA
6 MSS/E-FANS 3EM23911BBAB01 TH1829Q00FG  OK  NOK NA
7  OK  NOK NA
8  OK  NOK NA
 OK  NOK NA
 OK  NOK NA
 OK  NOK NA
III. NMS SUPERVISION
III.1. IP Address / Networking
Local NE IP Address 10.158.76.136
Local 7.1 /
MNGMT Port IP 10.158.67.37
Address 7.2
Subnet Mask 255.255.255.252

Direction1 Direction2 Direction3 Direction4

Local NE IP Address 10.158.76.140 NA NA NA


Remote MNGMT Port IP 7.1 /
Address Address
10.158.67.61 NA NA NA 7.2
Subnet Mask 255.255.255.252 NA NA NA

III.2. ROUTING
 IP Static Routing Configuration*
IP Destination Subnet mask Gateway

(*) Please Put NA if Not use Static for routing.

 Interface Pointer
Interface OSPF Area
TMN Management Ethernet 0.0.0.34
Port 4TMN Ethernet NA
Modem/MPT Access/EAS - Direction 1 0.0.0.34
Modem/MPT Access/EAS - Direction 2 NA
Modem/MPT Access/EAS - Direction 3 NA
Modem/MPT Access/EAS - Direction 4 NA

III.3 NE Supervision with 1353NM or 5620SAM


Refer to ATP
ITEM TEST SPECIFICATION RESULT
Paragraph
NE Supervision with
Alligned Up is successful  OK  NOK 14
5620SAM
IV. OUTDOOR UNIT CHECK & LINK TEST

Link Identification
Station 130153_SAMBIREJO GAMPENGREJO KEDIRI
Link Name
Direction 130151_YONIF 521 KEDIRI
Allocation :
Main Ch. Slot3 Slot4 Slot5 Slot6 Slot7 Slot8
 Modem300
 MPT Access
 EAS Card
Standby Ch. Slot3 Slot4 Slot5 Slot6 Slot7 Slot8

ITEM TO BE CHECKED STATUS Remark


Installation & Label of ODU & Antenna OK NOK NA
Antenna Sway Bar position/installation OK NOK NA
Installation of feeder/ coaxial /optical cable & Label OK NOK NA
Grounding for ODU, feeder or coaxial cable OK NOK NA
ODU connectors weatherproofing OK NOK NA
Lightning surge suppressor (outdoor) OK NOK NA

Diameter
Type Height (m) Part Number Serial Number Status
(m)

ANTENNA SYSTEM
SCX2-127BB 0.6 33 1AF27352AAAA 101129449-F005 OK NOK
CHECKING
Single Polarization  Dual Polarization
Polarization : Vertical Horizontal Used BOTH = V & H

 Radio Link Configuration Check


1+0  1 + 1 HSB  1 + 1 HSB/FD  1 + 1 HSB/SD  SA
Protection & Radio
Configuration Type
 2 x (1+1 HSB)  2+0 RLAG  3+ 0 RLAG  4 + 0 RLAG

Frequency band 7 / 8 GHz 11 GHz 13 GHz 15 GHz  23 GHz

Modulation Type  Static / Presetting  Adaptive Modulation


Packet Booster (PTB)
 Enable  Disable  NA
feature
Radio Link Test
Configuration 1+1 HSB
Refer to
Measurement ATP
Description Specification Paragraph
Main Standby
ISR
Tx / Rx Frequency
Refer to LPC 2.6
(MHz)
Actual on Field
(Far-end Tx-
Rx level of Interference (dBm) 15
mute/Off)
Expected (dBm) Refer to LPC 2.9
Tx power (dBm)
Detected (dBm) ± 2 dB from set 2.9

Expected (dBm) Refer to LPC 2.9


Rx Level (dBm)
Detected (dBm) ± 4 dB from LPC 2.9

Channel Spacing / Modulation (MHz/QAM) Refer to LPC

 For Parallel Link 2/3/4 + 0 RLAG


Link-Ch#1 / Ant- Link-Ch#2 / Ant- Link-Ch#3 / Ant- Link-Ch#4 / Ant-
Refer To LPC
Polarization Polarization Polarization Polarization
Tx/Rx Frequency ISR
(MHz) Actual on field 13199000 13199000
Interference Level (dBm) -99.6 -99.6
Refer to LPC 19.0 19.0
Tx Power (dBm)
± 2 dB from set 19.0 19.0
Refer to LPC -34.33 -34.33
Rx Power (dBm)
± 4 dB from LPC -36.8 -36.9
Ch. Spacing / Modulation (MHz / QAM) 28MHz/256QAM 28MHz/256QAM

 Protection Test
Refer to
MEASUREMENT ATP
ITEM TEST SPECIFICATION Paragraph
Main (Primary) Standby (Secondary)
Equipment
(EPS)
Working Normally OK NOK NA OK NOK NA
Link Protection
(Switching 1+1)* Tx Radio (TPS) Working Normally OK NOK NA OK NOK NA 2.5 / 2.11

Rx Radio (RPS) Working Normally OK NOK NA OK NOK NA
Core Board Protection Working Normally OK NOK NA 2.12
(*) For Configuration 1+1 HSB only
BER Circuit / Ethernet & Link Performance Checks
MEASUREMENT Refer to
ITEM TEST SPECIFICATION ATP
P32E1 (1) / Flow Id Paragraph

1 = 9 = 17  = 25  =

2 = 10  = 18  = 26  =

3 = 11  = 19  = 27  =

4 = 12  = 20  = 28  =
No Error at each
E1 Tributary Test * 3.4 / 16
ports for 1 min.
5 = 13  = 21  = 29  =

6 = 14  = 22  = 30  =

7 = 15  = 23  = 31  =

8 = 16  = 24  = 32  =

Link Performance
No Error (24h)  OK  NOK 9
Monitoring

Eth Throughput OK  NOK


Ethernet Port
refer to Modem 11
Functionality Test
setting profile Eth Throughput = _____157.64________ Mbps

* Please disabled the unused E1 or Ethernet port after test

V. ATTACHMENT CHECKING
Total
Page
ITEM TO BE ATTACH STATUS Number
of Remark
Pages
Print out of Network Topology OK NA

Module Remote Inventory & BoQ OK NA

Link Path Calculation (LPC) OK NA


BER Test / Link Performance Result (24h) OK NA
Print out of Capture:
 Interference test
 QoS setting
 RSL
OK NA
 License Key/String
 Equipment module composition
 MIB / File Configuration
 Eth Throughput

Attachement 2. Picture of Installation


1. Penempatan antena dari kaki tower 2. Pemasangan antenamain + label + barcode

3. Pemasangan ODU 2+0, abel + barcode 4. Pemasangan ODU 2+0, label + barcode

5. Pemasangan mounting antena 6. Pemasangan brackett mounting antena di kaki


tower (mur 2 set)
7. Pemasangan brackett antena di pipa mounting 8. Pemasangan kabel IF & ground ODU + label +
waterproof

NA
9. Terminasi ground ODU di busbar tower + label 10. Pemasangan kabel ties pada sisi vertikal tray

11. Pemasangan kabel ties pada sisi horisontal tray 12. Pemasangan grounding kit + label
N/A

13. Terminasi kabel ground kit di busbar + label 14. Posisi masuknya kabel IF di FEP Shelter/SC. FEP SC
tidak perlu di Sealent, FEP Shelter harus di Sealant.

15. Posisi IDU tampak depan dari SC/rak 19” 16. Pemasangan kabel IF, ground IDU/Modem + label

17. Pemasangan kabel traffic, power IDU + label 18. Label IDU dan barcodenya
NA
19. Pemasangan kabel IF, ground, + label 20. Pemasangan terminal blok LSA + label

N/A

21. Pemasangan kabel power di Rectifier/DCPDB 22. Kondisi shelter/SC tempat IDU terpasang tampak
depan

NA
23. Foto SID + Red mark 24. Foto Ketinggian Antenna(pakai meteran)
Punch List
Link ID 130151_130153

Link Name YONIF 521 KEDIRI_ SAMBIREJO GAMPENGREJO KEDIRI

Severity
Item No.

Plan Actual

Cosmetic
Clear Responsible Clear

Minor
Major
Description Supervisor
Date Group Date

Partner Managed Services

Name : Name :
Date : Date :

BMG H3I Representative

Name : Name :
Date : Date :