TMA2094F01V2-1

700 MHZ Twin TMA with 850-900 bypass, AISG2.0


Designed to be deployed in 700, 850/900MHz shared antenna systems, the
Kaelus TMA2094 provides gain at the 700MHz uplink band while allowing
850/900 services to pass through to the antenna thereby saving OPEX and
CAPEX.

PRODUCT FEATURES
Improved base station sensitivity through gain in 700Mhz band
Hardware and software configuration using AISG “Personality” upload
bypass for 850/900 bands with internal diplexing of the 807-960 and 700MHz bands
Fail safe bypass mode with lightning protection
Rejection of digital TV broadcast channels
High linearity and low noise performance

TECHNICAL SPECIFICATIONS
Downlink Path, Band 1 700

Passband 768 - 803


Insertion Loss 0.2dB typ, 0.4dB max

Return Loss 18dB min

Group delay variation 70ns max

Absolute group delay 80ns max

Max Average input power (W) 150

Max PEP Input Power (W) 1500

Intermodulation, 2 x 43dBm TX carriers (dBc) -150dBc max

Uplink Path, Band 1

Passband 713 - 748

Gain (dB) 16dB min


Gain window +/- 1dB max

|1 | © 2015 Kaelus Inc. All Rights Reserved. TMA2094F01V2-1


www.kaelus.com
Revised 24 MAR 15
Return Loss (Operating) 18dB min

Return Loss (Bypass) 12dB min

Group delay variation 150ns max


Absolute group delay 250ns max

Noise Figure 1.2dB typ, 1.6dB max

Bypass Loss 2.5dB typ, 3.2dB max

Output IP3 +30dBm typ

Maximum input power with no damage +12dBm max

RX filter rejection 50 – 694MHz 50dB min

Bypass Passband 807 - 960MHz

Insertion Loss 0.2dB typ, 0.4dB max

Return loss, all ports 18dB min

Continuous average power 160

Peak envelope power 1500


Intermodulation @ antenna port -150dBc max

GENERAL SPECIFICATIONS
AUTOSENSING FUNCTION ON ANT1 PORT see tma2094tbl1

CURRENT ALARM MODE (DEFAULT MODE SELECTED ON THE


ABSENCE OF AISG PACKETS)
DC Supply Voltage (VDC min) 8.5

DC Supply Voltage (VDC max) 30


Supply Current, Normal operation 150 +/- 20mA per port
Supply Current, alarm mode 220 +/- 20mA per port (programmable)

Power Consumption, Normal Mode 1.3W @ 8.5V, 4.5W @ 30V typ


Power consumption, alarm mode 3.3W @ 15V per port typ

AISG MODE OF OPERATION (AUTO SELECTED ON VALID AISG 2.0


FRAMES)
|2 | © 2015 Kaelus Inc. All Rights Reserved. TMA2094F01V2-1
www.kaelus.com
Revised 24 MAR 15
AISG Version 2
AISG Supply Current 220mA @ 8.5V, 70mA @ 30V typ

Power consumption, AISG mode 1.9W @ 8.5V, 2.1W @ 30V typ


AISG Connector IEC60130-9, 8-pin female
AISG Connector Current rating < 4A peak, 2A continuous, pin 6

Voltage drop, BTS to AISG port 1.5V max at 2A


Field firmware upgradable Yes

ENVIRONMENTAL
Temperature range -10ºC to +55ºC | -5°F to +131°F

Environmental sealing IP67


Altitude 2,600m | 8,530ft max

RF port: +/- 5kA max (8/20us), AISG port: +/- 2kA max (8/20us)
Lightning protection
IEC61312-1
MTBF >1,000,000 hours

Compliance EMC:EN301 489, Ingress ETSI EN 300 019 class 4.1, RoHS

MECHANICAL
Connectors DIN 7-16 (F) x 4 long neck, AISG (F) x 1

Dimensions, H x D x W 380 x 160 x 180mm | 14.96 x 6.3 x 7.1in


Finish Painted, light grey (RAL7035)

Weight 16.0kg | 35.27lbs


Pole/wall bracket supplied with two metal clamps 45-178mm
Mounting
diameter poles

ELECTRICAL BLOCK DIAGRAM

|3 | © 2015 Kaelus Inc. All Rights Reserved. TMA2094F01V2-1


www.kaelus.com
Revised 24 MAR 15
MECHANICAL BLOCK DIAGRAM

|4 | © 2015 Kaelus Inc. All Rights Reserved. TMA2094F01V2-1


www.kaelus.com
Revised 24 MAR 15
|5 | © 2015 Kaelus Inc. All Rights Reserved. TMA2094F01V2-1
www.kaelus.com
Revised 24 MAR 15

You might also like