PROJECT : PILOTES CODE: 1411100308

STUDENT : CANO VALVERDE WILDER DARWIN PLACE : HUARAZ

SUBJECT: INGENIERIA DE CIMENTACIONES DATE : 4/21/2021 TEACHER : JMAR

Pile Cap Design for 3-Piles Pattern Based on ACI 318-19


DESIGN CRITERIA
1. FROM PILE DESIGN & SOIL REPORT, DETERMINE SINGLE PILE MAX LOADS OR CAPACITY AT CAP BOTTOM FACE, fPn, fMn, & fVn.

2. THE MAXIMUM COLUMN CAPACITY AT COLUMN BASE, fPn,col, fMn,col, fVn,col, MAY BE BASED ON PILE CAP BALANCED LOADS.
USER CAN CHANGE THE YELLOW CELLS TO MODIFY THEM FOR DIFFERENT CASES.
3. PILE CAPS SHALL BE INTERCONNECTED BY TIES WITH Min(0.25, SDS/10) TIMES AXIAL VERT COLUMN LOADING. (IBC 1810.3.13)

INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH fc' = 4 ksi, (28 MPa)

REBAR YIELD STRESS fy = 60 ksi, (414 MPa)


PILE DIAMETER D = 20 in, (508 mm)
COLUMN SIZE (SHORT SIDE) C = 24 in, (610 mm)

SINGLE PILE MAX LOADS OR CAPACITY fPn = 130 kip, (59 Tn-f)

(at the section of cap bottom face) fMn = 400 ft-kip, (55 Tn-m)
fVn = 35 kip, (16 Tn-f)
PILE CLEAR DIST. (24" min, 2D reqd) Clear = 40 in, (1016 mm)
EDGE DISTANCE (9" min) Edge = 12 in, (305 mm) The Column Can Support Max Loads:
EFFECTIVE DEPTH d = 53 in, (1346 mm) Pu,col ≤ f Pn,col = 390 kip, (177 Tn-f)

CAP BOTTOM REINFORCING # 9 @ 16 in o.c., each way Mu,col ≤ fMn,col = 710.0 ft-kip, (98 Tn-m)
Vu,col ≤ fVn,col = 105 kip, (48 Tn-f)
THE PILE CAP DESIGN IS ADEQUATE.

ANALYSIS
CHECK FLEXURE CAPACITY AT COLUMN FACE (ACI 318 21,22, & 24.4.3.1)
Pile Spacing = 60 in
Cap Edge Length = 136.2 in
L1-1 = 77.0 in, length of section 1-1
L2-2 = 104.7 in, length of section 2-2
Mu, 1-1 = 113.4 ft-kips / ft, (to middle of cap elevation)
Mu, 2-2 = 123.7 ft-kips / ft, (to middle of cap elevation)
r provD = 0.0012
 M u, max 
0.85 f c'  1  1  
 0.383bd 2 f c' 
  
0.0008 < rprovD [Satisfactory]
fy

0.85 1 f c' u
 MAX   0.0206 > rprovD [Satisfactory]
fy u t

 T 4 
 MIN  MIN  0.0018 ,  0.0011 < rprovD [Satisfactory]
 d 3 

CHECK ONE WAY SHEAR CAPACITY AT THE FACE OF COLUMN & PILE
(ACI 318 22.5)
L3-3 = 62.4 in, length of section 3-3
Vu, 2-2 = 2 (fPn) / L2-2 = 0.0 kips / ft (No shear at "d" offset.)
Vu, 3-3 = (fPn) / L3-3 = 0.0 kips / ft (No shear at "d" offset.)

fVc = 2 f b d (fc')0.5 = 60.3 kips / ft > Vu, max [Satisfactory]


where f= 0.75 (ACI 318 21.2)

CHECK COLUMN PUNCHING CAPACITY (ACI 318 13.2.7.2, 22.6.4.1, 22.6.4.3, & 8.4.2.3)
P u ,col 0.5 v M u ,col b1
 v c( psi)    2  y  f 'c  190 ksi > v u ( psi)    31 ksi [Satisfactory]
AP J
1  4 d 
where bc = 1.00  v  1 
0.4 y  MIN  2, , 40   2.0
2 b1   b 0 
1  c
b1 = (C + d) = 77 in 3 b2
b2 = (C + d) = 77 in
b0 = 2b1 + 2b2 = 308 in  d b3    d  2  b 
Ap = b0 d J   1  1     3  2   
= 16324 in2  6    b1   b1   870 ft4
 
(cont'd)
CHECK SINGLE PILE PUNCHING CAPACITY (ACI 318 13.2.7.2, 22.6.4.1, 22.6.4.3, & 8.4.2.3)
P u ,col 0.5 v M u ,col b1
 v c( psi )    2  y  f 'c  95 ksi > vu ( psi )    49 ksi [Satisfactory]
AP J

where a= 134.1 deg


b1 = (a / 360) (Dp / 4 + d) = 26 in
b2 = (a / 360) (Dp / 4 + d) = 26 in
b0 = (a / 360) (D + d) p = 85 in, conservative value
Ap = b0 d = 4529 in2
 d b3    d  2  b 
J   1  1     3  2    59 ft4
 6    b1   b1  
 

1
 v  1 
2 b1 0.4
1
3 b2

y= 0 , conservative value as one way shear


PROJECT : PILOTES CODE: 1411100308

STUDENT : CANO VALVERDE WILDER DARWIN PLACE : HUARAZ

SUBJECT: INGENIERIA DE CIMENTACIONES DATE : 4/21/2021 TEACHER : JMAR

Pile Cap Design for 4-Piles Pattern Based on ACI 318-19


DESIGN CRITERIA
1. FROM PILE DESIGN & SOIL REPORT, DETERMINE SINGLE PILE MAX LOADS OR CAPACITY AT CAP BOTTOM FACE, fPn, fMn, & fVn.

2. THE MAXIMUM COLUMN CAPACITY AT COLUMN BASE, fPn,col, fMn,col, fVn,col, MAY BE BASED ON PILE CAP BALANCED LOADS.
USER CAN CHANGE THE YELLOW CELLS TO MODIFY THEM FOR DIFFERENT CASES.
3. PILE CAPS SHALL BE INTERCONNECTED BY TIES WITH Min(0.25, SDS/10) TIMES AXIAL VERT COLUMN LOADING. (IBC 1810.3.13)

INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH fc' = 4 ksi
REBAR YIELD STRESS fy = 60 ksi
PILE DIAMETER D = 20 in
COLUMN SIZE (SHORT SIDE) C = 24 in
SINGLE PILE MAX LOADS OR CAPACITY fPn = 130 k
(at the section of cap bottom face) fMn = 400 ft-k
fVn = 35 k
PILE CLEAR DIST. (24" min, 2D reqd) Clear = 40 in
EDGE DISTANCE (9" min) Edge = 12 in The Column Can Support Max Loads:
EFFECTIVE DEPTH d = 53 in Pu,col ≤ fPn,col = 520 kips
CAP BOTTOM REINFORCING # 9 @ 12 in o.c., each way Mu,col ≤ fMn,col = 946.7 ft-kips
Vu,col ≤ fVn,col = 140 kips
THE PILE CAP DESIGN IS ADEQUATE.

ANALYSIS
CHECK FLEXURE CAPACITY AT COLUMN FACE (ACI 318 21,22, & 24.4.3.1)
Pile Spacing = 60 in
Cap Edge Length = 104.0 in
L1-1 = 113.1 in, length of section 1-1
L2-2 = 104.0 in, length of section 2-2
Mu, 1-1 = 80.433 ft-kips / ft, (to middle of cap elevation)
Mu, 2-2 = 156.2 ft-kips / ft, (to middle of cap elevation)
rprovD = 0.0016
 M u, max 
0.85 f c' 1  1  
 0.383bd 2 f c' 
   0.0010 < rprovD [Satisfactory]
fy

0.85 1 f c' u
 MAX   0.0206 > rprovD [Satisfactory]
fy u t

 T 4  rprovD
 MIN  MIN  0.0018 ,   <
3 
0.0014 [Satisfactory]
 d

CHECK ONE WAY SHEAR CAPACITY AT THE FACE OF COLUMN & PILE
(ACI 318 22.5)
L3-3 = 82.2 in, length of section 3-3
Vu, 2-2 = 2 (fPn) / L2-2 = 0.0 kips / ft (No shear at "d" offset.)
Vu, 3-3 = (fPn) / L3-3 = 0.0 kips / ft (No shear at "d" offset.)

fVc = 2 f b d (fc')0.5 = 60.3 kips / ft > Vu, max [Satisfactory]


where f= 0.75 (ACI 318 21.2)

CHECK COLUMN PUNCHING CAPACITY (ACI 318 13.2.7.2, 22.6.4.1, 22.6.4.3, & 8.4.2.3)
P u , col 0.5 v M u, col b1
 v c( psi)    2  y  f 'c  190 ksi > vu ( psi)    42 ksi [Satisfactory]
AP J
1  4 d 
where bc = 1.00  v  1  0.4 y  MIN  2, , 40   2.0
2 b1   b 0 
1  c
b1 = (C + d) = 77 in 3 b2
b2 = (C + d) = 77 in
b0 = 2b1 + 2b2 = 308 in  d b3    d  2  b 
Ap = b0 d J   1  1     3  2   
= 16324 in2  6    b1   b1   870 ft4
 
(cont'd)
CHECK SINGLE PILE PUNCHING CAPACITY (ACI 318 13.2.7.2, 22.6.4.1, 22.6.4.3, & 8.4.2.3)

P u,col 0.5 v M u, col b1


 v c( psi)    2  y  f 'c  95 ksi > v u ( psi )    40 ksi [Satisfactory]
AP J

where a= 164.1 deg


b1 = (a / 360) (Dp / 4 + d) = 31 in
b2 = (a / 360) (Dp / 4 + d) = 31 in
b0 = (a / 360) (D + d) p = 105 in, conservative value
Ap = b0 d = 5542 in2

 d b3    d  2  b 
J   1  1     3  2    90 ft4
 6    b1   b1  
 

1
 v 1 
2 b1 0.4
1
3 b2

y= 0 , conservative value as one way shear


PROJECT : PILOTES CODE: 1411100308

STUDENT : CANO VALVERDE WILDER DARWIN PLACE : HUARAZ

SUBJECT: INGENIERIA DE CIMENTACIONES DATE : 4/21/2021 TEACHER : JMAR

Pile Cap Design for 2-Piles Pattern Based on ACI 318-19


DESIGN CRITERIA
1. FROM PILE DESIGN & SOIL REPORT, DETERMINE SINGLE PILE MAX LOADS OR CAPACITY AT CAP BOTTOM FACE, fPn, fMn, & fVn.

2. THE MAXIMUM COLUMN CAPACITY AT COLUMN BASE, fPn,col, fMn,col, fVn,col, MAY BE BASED ON PILE CAP BALANCED LOADS.
USER CAN CHANGE THE YELLOW CELLS TO MODIFY THEM FOR DIFFERENT CASES.
3. PILE CAPS SHALL BE INTERCONNECTED BY TIES WITH Min(0.25, SDS/10) TIMES AXIAL VERT COLUMN LOADING. (IBC 1810.3.13)

INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH fc' = 4 ksi
REBAR YIELD STRESS fy = 60 ksi
PILE DIAMETER D = 20 in
COLUMN SIZE (SHORT SIDE) C = 24 in
SINGLE PILE MAX LOADS OR CAPACITY fPn = 130 k
(at the section of cap bottom face) fMn = 400 ft-k
fVn = 35 k
PILE CLEAR DIST. (24" min, 2D reqd) Clear = 40 in
EDGE DISTANCE (9" min) Edge = 12 in The Column Can Support Max Loads:
EFFECTIVE DEPTH d = 53 in Pu,col ≤ fPn,col = 260 kips
CAP BOTTOM REINFORCING # 9 @ 12 in o.c., each way Mu,col ≤ fMn,col = 473.3 ft-kips
Vu,col ≤ fVn,col = 70 kips
THE PILE CAP DESIGN IS ADEQUATE.

ANALYSIS
CHECK FLEXURE CAPACITY AT COLUMN FACE (ACI 318 21,22, & 24.4.3.1)
Pile Spacing = 60 in
Cap Edge Length = 104.0 in
L1-1 = 44.0 in, length of section 1-1
Mu, 1-1 = 104.4 ft-kips / ft, (to middle of cap elevation)
rprovD = 0.0016

 M u, max 
0.85 f c 1  1  
'

 bd 2 f c  rprovD
'
0.383
   0.0007 < [Satisfactory]
fy

0.85 1 f c' u rprovD


 MAX   0.0206 > [Satisfactory]
fy u t


 MIN  MIN  0.0018
T
,
4 
 0.0009 < rprovD [Satisfactory]
 d 3 
CHECK ONE WAY SHEAR CAPACITY AT THE FACE OF COLUMN & PILE
(ACI 318 22.5)
L2-2 = 44.0 in, length of section 2-2
Vu, 1-1 = (fPn) / L1-1 = 0.0 kips / ft (No shear at "d" offset.)
Vu, 2-2 = (fPn) / L2-2 = 0.0 kips / ft (No shear at "d" offset.)

fVc = 2 f b d (fc')0.5 = 60.3 kips / ft > Vu, max [Satisfactory]


where f= 0.75 (ACI 318 21.2)

CHECK COLUMN PUNCHING CAPACITY (ACI 318 13.2.7.2, 22.6.4.1, 22.6.4.3, & 8.4.2.3)

P u ,col 0.5 v M u ,col b1


 v c( psi )    2  y  f 'c  190 ksi > v u ( psi )    31 ksi [Satisfactory]
AP J
bc = 1  4 d 
where 1.00  v  1  0.49367 y  MIN  2, , 40   2.0
2 b1   b 
b1 = (C + d) = 77 in 1  c 0
3 b2
b2 = [(C + min(Edge , d)] = 36 in
b0 = 2b1 + 2b2 = 226 in
 d b3    d  2  b 
Ap = b0 d = 11978 in2 J   1  1     3  2    559 ft4
 6    b1   b1  
 
(cont'd)
CHECK SINGLE PILE PUNCHING CAPACITY (ACI 318 13.2.7.2, 22.6.4.1, 22.6.4.3, & 8.4.2.3)

P u ,col 0.5 v M u ,col b1


 vc( psi)    2  y  f 'c  95 ksi > v u ( psi)    67 ksi [Satisfactory]
AP J
where a= 94.3 deg
b1 = (a / 360) (Dp / 4 + d) = 18 in
b2 = (a / 360) (Dp / 4 + d) = 18 in
b0 = (a / 360) (D + d) p = 60 in, conservative value
Ap = b0 d = 3185 in2

 d b3    d  2  b 
J   1  1     3  2    31 ft4
 6    b1   b1  
 

1
 v  1  0.4
2 b1
1
3 b2

y= 0 , conservative value as one way shear