Download as pdf
Download as pdf
You are on page 1of 2
Lined Valves Lined Valves Emerson supplies adverse range of bal butterfly and sampling valves the wetted parts of which are lined for resistance to coresion ina ‘multitude of applications in industles suchas chemical, peto-chemical, pharmaceutical, pulp and pape, semiconductor (UPW), foundries and ‘mining. A dedicated reactor sampling valve enables samples to be taken from reactorsor vessels containing poisoned, biological, corosive or ee Neotecha Neotecha PTFE, TFM and PFA lined valves ae designed for highly corrosive ‘media. The molding technique ‘of applying PFA vera metal core achieving mechanical strength from the core and chemical resistance from. the encapsulation has given Neotecha ‘valves a worldwide reputation for reliability inthe most severe corrosive applications. ‘Automated Valves froma singlesource Emerson solation valves are avalable as complete automated valve solutions supplied as a single product rather than packaged components. See page 32or more details. oo Neotecha Ball Valves Lined ball valve. High performance tned ball valves for 'solation and control in highly corrosive and highly toxic applications. Features + Fully PFA ined body offering the highest corrosion resistance + Precision machinedball and seats ‘uarantees aleakfee vale + One piece ballstem prevents lining damage and eliminates hysteresis + Patented sella ensures lowest fugtive emissions andis maintenance ree + Optimized process Tow for on-off ‘oral for controlapplications + Elimination of static electricity + Low torque throughout its fe cycle + Teuftand 150 1548-1 cestified Technical Data Sizerange: DN 150 150(NPS 1106) Pressure class: Fullvacuum to NI Temperature range: A to 20'C(-40" toa 10F) Applications ‘Chemicals pharmaceutical food & beverage Butterfly Neotecha NeoSeal Lined butterfly valve, LUned buttery vale for highly corrosive liquids, gases and slurry. Features ‘Taft approved valve with mechanical loaded shat seals + tra pure water approved with assembly Inclean room (level 8) + Machined to close tolerances fr low ‘torque and reduced stressdeformation during operation + Cxcllent sealing properties using ‘elastomer pads behind the tines + Improved protection using thick ining ‘on disc (3 mim) + Serrated body flanges reducing the cokt flow ofthe seat, Technical Data Sizes: DN 40 to 900 (NPS 1150 36) Pressure lass: Fullvacaum to PNIO Temperature range: 40° to 200°C 40" to 392"F) Applications ‘Chemical & pharmaceutical, semiconductor and food & beveraae (Check Valve / Sight Glass | Neotecha KR and SG Lined ball check valve/sight glass. Heavy duty lined products preventing back flow or providing overflow protection. Features + Heavy duty body in ductile ron GGG4D.3 (ASTM A395) * Heavy duty PFA lining + Borosicate glas for temperatures up to 200°C + PTFE ball quded with 4 ibs for vertical, andhorizontal applications | Replaceable some sears m EFUM, FEM and Perluor For bubble tightness + Blind coversin carbon steelor glass protector in FEP for HF application + Sutable for full vacuum + Leakfree lange connection Technical Data Sizes: (DN 25080 (NPS 1 103) Pressure cla Full vacuum to PNI6 Temperature range: 40° to 200°C (40° t0 392*F) Applications (Chemical & pharmaceutical pulp & paper, fade beverage Sampling % L bed ° oud * ‘Neotecha Sapro Incline sampling vale, Compact n-ne sampling solution forthe extraction oftepresentative high corrosive and or tonic samples rom pipelines ‘or reaction vessels without process interuption Features, + Assuresa'truc representative sample ‘without dead volumes + The sampling systems ofered with either a bottle or syinge collection ‘method + The syinge collect method utizes a bayonet connection, which isthe same for allsizes + Alltypes are provided with spring return manual lever + Standard bottle adpter version allows padlocking to prohibit sample taking when not required + The eliablty of each sample is assured ‘due tothe ease of assembly and ‘disassembly for cleaning + seat change is quickand easy witha universal seat for al sizes + TALuft approved Technical Nata Siaes: DN 25to 100(NPS 110.4) Pressure: Vacuum to 16/25 bar(232/363 ps) Temperature range: Upto 200°C (392°F) ‘Sample volume bottle 50-2000 ml ‘Sample volume syringe: 20-250 ml Applications ‘Chemical & pharmaceutical, pulp & paper. food & beverage Neotecha Type PV Reactor sampling system. ‘Complete sampling systems designed to handle highly corrosive liquldsby sampling within a closeé environment. Features + Aspecial engineered transfer device extracts sample without stopping the process or opening the reactor + Safe and simple operation using pressure less sample transfer + Allwetted parts are PTFE, PFA or glass + No contamination ofthe atmosphere _and sample media can be returned tothe reactor + Automated sampling possible by adding pheumatic actustors + Options include fitting pH probe, ‘vacuumjnitrogen(rinsing supply ines Technical Data ‘Sample volume: 150)250/500 ml Pressure: ‘upto 10bar (145 ps) ‘Temperature: ‘upto200°C(392"F) Applications ‘Chemical & pharmaceutical ood & beverage

You might also like