Professional Documents
Culture Documents
Miniature Basic Switch D2MV
Miniature Basic Switch D2MV
Miniature Basic Switch D2MV
RC
Ordering Information
Model Number Legend
D2MV-jj-jjj
1 2 3 4 5
Note: Consult your OMRON sales representative for details on SPST-NO and SPST-NC models.
133
D2MV D2MV
Specifications
Ratings
Model D2MV-1 D2MV-01
Rated voltage Item Resistive load
125 VAC 1A 0.1 A
30 VDC 1A 0.1 A
Note: The ratings values apply under the following test conditions:
Ambient temperature: 20±2°C
Ambient humidity: 65±5%
Operating frequency: 30 operations/min
Model Voltage
g Non-inductive load Inductive load
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
D2MV-1 125 VAC 1A 0.1 A --- ---
(1 A type)
8 VDC 1A 0.1 A --- ---
14 VDC 1A 0.1 A
30 VDC 1A 0.1 A
D2MV-01 125 VAC 0.1 A --- --- ---
(0 1 A type)
(0.1
8 VDC 0.1 A --- --- ---
14 VDC 0.1 A
30 VDC 0.1 A
Note: 1. The above values are for the steady-current state.
2. Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
Characteristics
Operating speed 1 mm to 1 m/s (pin plunger models)
Operating frequency Mechanical: 300 operations/min max.
Electrical: 30 operations/min max.
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance (initial D2MV-01 models: 50 mΩ max.
value) D2MV-1 models: 30 mΩ max.
Dielectric strength (see 1,000 VAC, 50/60 Hz for 1 min between terminals of same polarity
note 2) 1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and the ground
1,500 VAC, 50/60 Hz for 1 min between each terminal and non-current-carrying metal parts
Vibration resistance (see Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
note 3)
Shock resistance Destruction: Models with OF of 0.10 N: 150 m/s2 {approx. 15G} max.
(see note 3) Models with OF between 0.25 and 0.49 N: 400 m/s2 {approx. 40G} max.
Malfunction: 100 m/s2 {approx. 10G} max.
Durability (see note 4) Mechanical: 10,000,000 operations min. (60 operations/min) (Refer to Engineering Data.)
Electrical: D2MV-1 models: 500,000 operations min. (30 operations/min)
D2MV-01 models: 1,000,000 operations min. (30 operations/min)
(Refer to Engineering Data.)
Degree of protection IEC IP40
Degree of protection Class I
against electric shock
Proof tracking index (PTI) 175
Ambient operating –25°C to 80°C (at ambient humidity of 60% max.) (with no icing)
temperature
Ambient operating 85% max. (for 5°C to 35°C)
humidity
Weight Approx. 6 g (pin plunger models)
134
D2MV D2MV
135
D2MV D2MV
Contact Specifications
Item D2MV-01 models D2MV-1 models
SPST-NC
Contact Specification Twin crossbar Needle
Material Gold alloy Silver
Gap 0.5 mm
(standard
value)
Inrush NC 0.1 A max. 1 A max.
currentt NO
Minimum applicable 1 mA at 5 VDC 30 mA at 5 VDC SPST-NO
load (see note)
D2MV-01
Ambient temperature: 20±2°C
Ambient humidity: 65±5%
Without load
Operating frequency: 300 operations/min D2MV-1
Percentage of OT to its rated value (%) Percentage of switching current to its rated value (%)
136
D2MV D2MV
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Terminals Mounting Holes
Two, 3.1-dia. mounting holes or
M3 screw holes
6.5
6.3
7.5
6.3
22.2 ± 0.1
3.2
1.2
4.75±0.1
3 +0.07
–0.05
+0.15
3.2 –0.07 dia.
10.3
t=0.5
22.2±0.1 2.8 4 Three, solder terminals
31.8
Note: The j in the model number (7.5)
is for the OF code. 39.3±0.8
137
D2MV D2MV
138
D2MV D2MV
Precautions
Refer to pages 26 to 31 for common precautions. Using Micro Loads
Cautions Using a model for ordinary loads to open or close the contact of a
micro load circuit may result in faulty contact. Use models that oper-
Handling ate in the following range. However, even when using micro load
Be careful not to drop the Switch. Doing so may cause damage to models within the operating range shown below, if inrush current oc-
the Switch’s internal components because it is designed for a small curs when the contact is opened or closed, it may increase contact
load. wear and so decrease durability. Therefore, insert a contact protec-
tion circuit where necessary.
Correct Use The minimum applicable load is the N-level reference value. This
value indicates the malfunction reference level for the reliability lev-
Mounting el of 60% (λ 60). The equation, λ 60 = 0.5 10–6/operations indi-
Use M3 mounting screws with plane washers or spring washers to cates that the estimated malfunction rate is less than 1/2,000,000
securely mount the Switch. Tighten the screws to a torque of 0.39 to operations with a reliability level of 60%.
0.59 N S m {4 to 6 kgf S cm}.
Mounting Direction
Voltage (V)
Operating Operating
range for range for
D2MV-01 D2MV-1
Inoperable
range
Current (mA)
139