Professional Documents
Culture Documents
8-16mm A Series EP1149-0
8-16mm A Series EP1149-0
8-16mm A Series EP1149-0
(06/11/10)
A Series Miniature Control Units
Series A6 Series Miniature Control Units
Mounting Hole Size ø16
Type AL6 AB6 AB6M-V AS6 AS6 (key)
Appearance
Configuration
Contact Rating
110V AC · 1A, 24V DC · 1A
(resistive load)
Approvals
Page 5 8 9 10 11
(06/11/10)
2
A Series Miniature Control Units
Series A Series Miniature Control Units
Mounting Hole Size ø12 ø10 ø8
Type AL2 AB2 AL1 AB1 AL8 AB8
Appearance
Bezel Size
(Operator Size) ø14 14 14 ×18 ø12 12 12 ×16 ø9 9 9 × 12
Configuration
Contact Rating
110V AC · 1A, 24V DC · 1A 110V AC · 1A, 24V DC · 1A 110V AC · 1A, 24V DC · 1A
(resistor load)
Momentary: Momentary: Momentary:
100,000 operations minimum 100,000 operations minimum 100,000 operations minimum
Electrical
Maintained: Maintained: Maintained:
Durability
Remarks
Approvals
Page 25 26 32 33 38 39
Note: LED lamps do not have a current-limiting resistor, and external resistor must be provided.
(06/11/10)
3
ø16 A6 Series Miniature Control Units
Light duty type in short 22mm body length.
• Features IDEC’s original mechanism for snap-action switching.
Suitable for a wide variety of office and factory aplications.
• The LED lamp contains a current-limiting resistor and a diode for
protection against reverse connection.
• 16-mm mounting holes
• Available in enclosed (IP40) and waterproof (IP65), and oiltight
types.
• UL recognized, CSA certified, and EN compliant
Zener Diode
(06/11/10)
4
A6 Series Miniature Control Units ø16
(06/11/10)
5
ø16 A6 Series Miniature Control Units
Type No.
Shape Operating Voltage ➁ Lens Color Code
IP40 IP65
Round
AL6M-P
5V DC ±5% AL6M-P1➁ AL6M-P1P➁
(06/11/10)
6
A6 Series Miniature Control Units ø16
Dimensions (Illuminated Pushbuttons & Pilot Lights)
Rubber Gasket
Terminal Width 2.8×0.5t Panel Thickness 0.5 to 6
Anti-rotation Ring ø18
2.5 3 Rectangular Square Round
Locking Ring Rectangular w/3-way barrier (TOP)
(TOP)
(TOP)
5
18
5
1 0.6 5.7
6 6 24 c18
8 22 9 9
Pilot Light Illuminated Pushbutton
NC1 NC2
NO1 NO2
C1 C2
Lamp Lamp Lamp Lamp
Terminal (+) Terminal (–) Terminal (+) Terminal (–)
18 min.
centers to ensure
easy operation.
18 min. 24 min.
(06/11/10)
7
ø16 A6 Series Miniature Control Units
AB6 Pushbuttons
Dimensions
Rubber Gasket Panel Thickness 0.5 to 6
(Pushbutton)
Terminal Width 2.8×0.5t Anti-rotation Ring Rectangular Square Round ø18
2.5 3 Rectangular w/3-way barrier
Locking Ring (TOP) (TOP)
(TOP)
5
18
5
1 0.6 5.7
24 18
8 22 9 9
centers to ensure
easy operation.
NO1 NO2
C1 C2
18 min. 24 min.
All dimensions in mm.
(06/11/10)
8
A6 Series Miniature Control Units ø16
Type No.
Shape Operation Type Contact Button Color Code
IP40 IP65
AB6M-V
SPDT AB6M-V1R AB6M-V1PR
Dimensions
(Pushlock Turn Reset Pushbutton)
Rubber Gasket
Terminal Width 2.8×0.5t Anti-rotation Ring
Panel Thickness 0.5 to 6
2.5 3 Locking Ring
ø23.5
5
5
1 0.6 9.5
8 22 15.5
NO1 NO2
C1 C2
(06/11/10)
9
ø16 A6 Series Miniature Control Units
Type No.
Shape Position Contact
IP40 IP65 Contact Operation
Round SPDT AS6M-2Y1 AS6M-2Y1P
2-position
Maintained Operation
AS6M- Y DPDT AS6M-2Y2 AS6M-2Y2P
Position Type Left Center Right
90°
90° 2-position
Maintained
3-position
right C C C C
Spring return from SPDT AS6Q-21Y1 AS6Q-21Y1P
DPDT
right to left DPDT AS6Q-21Y2 AS6Q-21Y2P L
C
R
Maintained DPDT AS6Q-3Y2 AS6Q-3Y2P
3-position
C
L R
Spring return from left DPDT AS6Q-32Y2 AS6Q-32Y2P
to center
45° 3-position
C
L R
Spring return from SPDT AS6H-21Y1 AS6H-21Y1P
right to left DPDT AS6H-21Y2 AS6H-21Y2P C C C C C C
Spring
Maintained DPDT AS6H-3Y2 AS6H-3Y2P return from
left
3-position
L R
Spring return DPDT AS6H-32Y2 AS6H-32Y2P
from left to center Two-way
Spring return two-way DPDT AS6H-33Y2 AS6H-33Y2P return
Dimensions
Rubber Gasket Panel Thickness 0.5 to 6
Terminal Width 2.8×0.5t
Anti-rotation Ring Rectangular Square Round
2.5 3 (TOP) (TOP) (TOP)
Locking Ring
8
ø1
5
18
5
1 8
8 22 15.5 24 c18
(TOP)
NC1 NC2
18 min.
18 min.
NO1 NO2
C1 C2
18 min. 24 min.
SPDT has NC1, NO1, and C1 only.
Note: Determine mounting centers to ensure easy operation. All dimensions in mm.
(06/11/10)
10
A6 Series Miniature Control Units ø16
C
L R
B DPDT AS6M-3KT2B AS6M-3KT2PB
C
L R
C DPDT AS6M-3KT2C AS6M-3KT2PC
C
L R
Maintained D DPDT AS6M-3KT2D AS6M-3KT2PD
C
L R
E DPDT AS6M-3KT2E AS6M-3KT2PE
C
L R
G DPDT AS6M-3KT2G AS6M-3KT2PG
C
L R
H DPDT AS6M-3KT2H AS6M-3KT2PH
45°
3-position L
C
R
B DPDT AS6M-31KT2B AS6M-31KT2PB
C
L R
Spring return from right D DPDT AS6M-31KT2D AS6M-31KT2PD
C
L R
G DPDT AS6M-31KT2G AS6M-31KT2PG
C
L R
C DPDT AS6M-32KT2C AS6M-32KT2PC
C
L R
Spring return from left D DPDT AS6M-32KT2D AS6M-32KT2PD
C
L R
H DPDT AS6M-32KT2H AS6M-32KT2PH
C
L R
Spring return two-way D DPDT AS6M-33KT2D AS6M-33KT2PD
Contact Operation
Operator Position & Contact Operation (Top View)
NO NC NO NC
SPDT —
L R L R C C
(06/11/10)
11
ø16 A6 Series Miniature Control Units
C
L R
B DPDT AS6Q-3KT2B AS6Q-3KT2PB
C
L R
C DPDT AS6Q-3KT2C AS6Q-3KT2PC
C
L R
Maintained D DPDT AS6Q-3KT2D AS6Q-3KT2PD
C
L R
E DPDT AS6Q-3KT2E AS6Q-3KT2PE
C
L R
G DPDT AS6Q-3KT2G AS6Q-3KT2PG
C
L R
H DPDT AS6Q-3KT2H AS6Q-3KT2PH
45°
3-position L
C
R
B DPDT AS6Q-31KT2B AS6Q-31KT2PB
C
L R
Spring return from right D DPDT AS6Q-31KT2D AS6Q-31KT2PD
C
L R
G DPDT AS6Q-31KT2G AS6Q-31KT2PG
C
L R
C DPDT AS6Q-32KT2C AS6Q-32KT2PC
C
L R
Spring return from left D DPDT AS6Q-32KT2D AS6Q-32KT2PD
C
L R
H DPDT AS6Q-32KT2H AS6Q-32KT2PH
C
L R
Spring return two-way D DPDT AS6Q-33KT2D AS6Q-33KT2PD
Contact Operation
Operator Position & Contact Operation (Top View)
NO NC NO NC
SPDT —
L R L R C C
90° 2-position
Left Right Left Right
Maintained Spring return from right Contact Contact Contact Contact
NO NC NO NC NO NC NO NC
DPDT —
C C C C
(06/11/10)
12
A6 Series Miniature Control Units ø16
C
L R
B DPDT AS6H-3KT2B AS6H-3KT2PB
C
L R
C DPDT AS6H-3KT2C AS6H-3KT2PC
C
L R
Maintained D DPDT AS6H-3KT2D AS6H-3KT2PD
C
L R
E DPDT AS6H-3KT2E AS6H-3KT2PE
C
L R
G DPDT AS6H-3KT2G AS6H-3KT2PG
C
L R
H DPDT AS6H-3KT2H AS6H-3KT2PH
45°
3-position L
C
R
B DPDT AS6H-31KT2B AS6H-31KT2PB
C
L R
Spring return from right D DPDT AS6H-31KT2D AS6H-31KT2PD
C
L R
G DPDT AS6H-31KT2G AS6H-31KT2PG
C
L R
C DPDT AS6H-32KT2C AS6H-32KT2PC
C
L R
Spring return from left D DPDT AS6H-32KT2D AS6H-32KT2PD
C
L R
H DPDT AS6H-32KT2H AS6H-32KT2PH
C
L R
Spring return two-way D DPDT AS6H-33KT2D AS6H-33KT2PD
Contact Operation
Operator Position & Contact Operation (Top View)
NO NC NO NC
SPDT —
L R L R C C
(06/11/10)
13
ø16 A6 Series Miniature Control Units
Dimensions
Right Contact
2.5
TOP
3
Left Contact
Rubber Gasket
Anti-rotation Ring Panel Thickness 0.5 to 6 Rectangular Square Round
Terminal Width 2.8×0.5t (TOP) (TOP) (TOP)
Locking Ring
2.5 3
NC
5
18
NO
5
8 22 26 24 18 ø18
(TOP)
NC1 NC2
NO1 NO2
C1 C2
+0.2 +0.2
ø16.2 0 ø16.2 0
18 min.
18 min.
18 min. 24 min.
(06/11/10)
14
A6 Series Miniature Control Units ø16
Accessories
Ordering Package
Shape Material Type No. Dimensions (mm)
Type No. Quantity
Locking Ring Wrench • Used to tighten the locking ring when
ø18 Metal installing A6 control units into a panel.
(nickel-plated MT-001 MT-001 1
brass) • Tighten the locking ring to a torque of
60 0.88 N·m maximum.
Lamp Holder Tool ø9
• Used to install and remove the LED
Rubber OR-77 OR-77 1
ø10 lamps.
55
Mounting Hole
Nitryl rubber
6
ø1
Metal
.2 +
Mounting Hole
6
(diecast)
ø17.8
ø1
(06/11/10)
15
ø16 A6 Series Miniature Control Units
Maintenance Parts
Package
Shape Specification Type No. Ordering Type No. Color Code ➀➁
Quantity
Lens Specify a color code in place of ➁
Round AL6M-L➁ AL6M-L➁PN05
in the Type No.
A (amber), C (clear), G (green)
Square Polyarylate AL6Q-L➁ AL6Q-L➁PN05
R (red), S (blue), Y (yellow)
• Use a C (clear) lens for W (white)
Rectangular AL6H-L➁ AL6H-L➁PN05 and JW (pure white) illumination.
Button Round AB6M-B➀ AB6M-B➀PN05 Specify a color code in place of ➀
5 in the Type No.
Square Polyarylate AB6Q-B➀ AB6Q-B➀PN05
B (black), G (green), R (red)
Rectangular AB6H-B➀ AB6H-B➀PN05 S (blue), W (white), Y (yellow)
10
Anti-rotation Ring
Spare key
For key selector Brass with
AS6-SK-132 AS6-SK-132PN02 2 • Thickness 2.0 mm
switches nickel plating
LED Lamps
Current Draw Ordering ➁ Illumination Package
Operating Voltage Type No. Base
AC DC Type No. Color Code Quantity
5V DC ±5% LATD-5➁ 1
Specify a color code
— 8 mA LATD-5➁ in place of ➁ in the
LATD-5➁PN10 Ordering Type No. 10
12V AC/DC ±10% A: amber
LATD-1➁ 1 Exclusive
9 mA 8 mA LATD-1➁ G: green for A6
LATD-1➁PN10 JW: pure white 10 series
R: red
24V AC/DC ±10% LATD-2➁ S: blue 1
9 mA 8 mA LATD-2➁ W: white
LATD-2➁PN10 Y: yellow 10
(06/11/10)
16
A6 Series Miniature Control Units ø16
Transformer
Shape Primary Voltage Secondary Voltage Type No. Applicable LED Lamp
Separate Mounting Type for 24V 100/110V AC TWR512
400/440V AC TWR542
• Terminal covers are supplied with separate mounting type transformers.
• Connect only one LATD LED to separate mounting type transformers.
• Use mounting bracket BC9Z-E/NS35N when using on 400/440V primary voltage.
Dimensions
Specifications M3.5 Terminal Screws
100/110V AC, 200/220V AC,
Operating Voltage
400/440V AC (50/60 Hz)
Power Consumption 2.4VA
22
30
Secondary Side Primary Side
Rated Insulation Voltage 600V
Insulation Resistance 100 MΩ minimum (500V DC megger)
Operating Mounting Holes 40
Standard –30 to +60°C (no freezing) 2-ø3.3 48
Temperature
Operating Condition
Relative Humidity 35 to 85% (no condensation)
52
Operation
Vibration Resistance 5 to 55 Hz, amplitude 0.5 mm
Extremes
Shock Resistance Damage Limits 1,000 m/s2
Terminal
Dielectric Strength 2500V AC, 1 minute
41
40
Cover
Terminal Screw M3.5
Applicable Wire 2 mm2 maximum, 2 wires maximum
Accessories
Package
Description Appearance Description Type No. Ordering Type No.
Quantity
Aluminum
BAA1000 BAA1000PN10
Weight: Approx. 200g
DIN Rail
Steel
BAP1000 BAP1000PN10
Weight: Approx. 320g
Steel 10
BNL6 BNL6PN10
Weight: Approx.15g
Weight: Approx.15g
Maintenance Parts
Dimensions
• Switch Guard (Degree of protection: IP40)
Panel Thickness
34 0.5 to 5
For Round/Square Units For rectangular units
(AL-K6) (AL-K6S) (AL-KH6) (AL-KH6S) Panel Thickness
(45.5 minimum for 180° opening type)
32 0.5 to 5
18 24 R2
2
33
13
13
23.5
23.5
10.5
10.5
26.5 minimum
26.5 minimum
(06/11/10)
17
ø16 A6 Series Miniature Control Units
• Switch Guard (Degree of protection: IP65)
Panel Thickness
For Round/Square Units For Rectangular Units 34 0.5 to 5
(AL-K6SP) (AL-KH6SP)
Waterproof Gasket
18 24 R2 for Switch Guard
2
33
10.5 13
10.5 13
23.5
23.5
45.5 min.
45.5 min.
Rubber
Gasket
0.4
14 28
19 min. 25 min.
• Socket
+0.3
TOP Terminal 1.5×0.3t 8-1.6 0 Holes
33.5 2.5 3 33.5 2.5 3
2.4
(TOP)
NC1 NC2
5 5
5 5
NO1 NO2
• Terminal Cover
17.3
For Round Units For Square Units For Rectangular Units Round/Square Units Rectangular Units
(AL-D6) (AL-DQ6) (AL-DH6)
ø24 c 24 30 +0.2 +0.2
ø16.2 0 ø16.2 0
24
24 min.
24 min.
13
13
13
7.5
7.5
7.5
24 min. 30 min.
0.3
0.3
0.3
17.5
(06/11/10)
18
A6 Series Miniature Control Units ø16
Safety Precautions
• Turn off the power to A series control units before starting • For wiring, use wires of a proper size to meet the voltage and
installation, removal, wiring, maintenance, and inspection of the current requirements. Failure to tighten terminal screws may
control units. Failure to turn power off may cause electrical shocks cause overheating and create a fire hazard.
or fire hazard.
• To avoid a burn on your hand, use the lamp holder tool when
replacing lamps.
Operating Instructions
Replacement of Lens and Marking Plate Panel Mounting
• Removal When mounting the control units into a panel, use the optional
locking ring wrench (MT-001) to tighten the locking ring. Do not use
Remove the lens assembly (color lens, marking plate, lens holder,
pliers. Tightening torque must not exceed 0.88 N·m. Excessive
and spring) by holding the color lens recesses with the Lens
tightening will damage the locking ring.
Removal Tool (MT-101) and pulling it out. Remove the marking plate
by disengaging the latches between the color lens and lens holder.
The marking plate must be Fitting Grooves
Wiring
engraved on the front side Grooves Solder the terminal at 350°C within 3 seconds using a 60W
as shown at right. soldering iron. Sn-Ag-Cu type is recommended when using lead-
When using a color film, free solder. When soldering, do not touch the control unit with the
insert it between the color soldering iron. Also ensure that no tensile force is applied to the
Engraving terminal. Do not bend the terminal or apply excessive force to the
lens and marking plate. Surface
terminal. Use a non-corrosive rosin flux.
• Installation Color Lens Marking Plate Lens Holder
Place the marking plate on Installing the Socket
the lens holder in the correct direction, and press the color lens onto
Install the socket on the control unit with the TOP markings on the
the lens holder to engage the latches.
control unit and the socket placed in the same direction.
Put the spring on the lens holder and insert the lens holder into the
housing in the correct direction.
Switch Guard
Marking Waterproof (IP65) / oiltight type switch guards must be used with
waterproof (IP65) / oiltight type control units only. Even if IP65 type
For A series illuminated pushbuttons, legends and symbols can be switch guards are installed, enclosed type (IP40) control units are
engraved on the built-in marking plates, or printed film can be not made waterproof.
inserted under the lens for labelling purposes.
Switch Guard
Item
Marking Plate & Engraving Area IP65 (waterproof) IP40 (enclosed type)
Engraving
ø12.0
Engraving
Engraving Area
Area
Area
0.8
Engraving Area
• Engraving must be made on the engraving area within 0.5mm Other Notes
deep.
• The marking plate is made of white acrylic resin. • Close Proximity Mounting
When mounting pilot lights or illuminated pushbuttons collectively or
lighting them continuously, heat may cause the ambient
ø13.6
Applicable the mounting panel is not made of metal or when the control units
Marking Film are mounted in an enclosed panel, provide for ventilation or lower
(not supplied) 11.8 c13.6 19.6
the operating voltage.
• Thickness = 0.1 mm × 1 film • Replacement of Buttons (Illuminated/Non-illuminated)
• Recommended film material: polyester
Do not replace buttons of maintained action units while the button is
in the locked position. Replacing the button in the locked position
Replacing the LED Lamp may damage the internal mechanism. Be sure to release the button
before replacing.
• Removal
• Operating and Storage Environment
Use the lamp holder tool (OR-77) to remove lamps. Do not use
pliers. 1. Make sure that the operating/storage temperature and humidity
are within the ratings.
• Installation 2. Do not use enclosed type units in an environment subject to oil,
Use the lamp holder tool (OR-77) to install lamps. Note the correct water or dust accumulation. In such an area, use the waterproof/
side of the tool for removal or installation. oiltight units (IP65).
For installing lamps For removing lamps • Microswitch Contacts
Do not connect NO and NC contacts of a microswitch to different
voltages or different power sources to prevent a dead short-circuit.
ø10
ø9
OR-77
• IP65 Type Units
55 IP65 type units are evaluated by conventional cutting and cooling
oils, and can not be used with some special oils. Contact IDEC for
All dimensions in mm.
resistance against specific oils.
(06/11/10)
19
ø16 Flush Silhouette L6/A6 Series Accessories
New flush silhouette bezels for L6/A6 series ø16mm miniature control units
• Accessories for L6/A6 control units.
• Bezel Size
Round: ø24 mm (Panel Cut-out: ø20.2 mm)
Square: 24 mm (Panel Cut-out: 20.2 mm)
Rectangular: 24×30 mm (Panel Cut-out: 20.2×26.2 mm)
• Applicable models
L6 Series A6 Series
Illuminated Pushbutton Illuminated Pushbutton
Pilot Light Pilot Light
Pushbutton Pushbutton
Selector Switch Selector Switch
Key Selector Switch Key Selector Switch
Illuminated Selector Switch Illuminated Selector Switch
Lever Switch
Buzzer
Note: Flush silhouette bezels cannot be used for mushroom buttons or lenses.
Flush Bezel
Shape Specification Type Package Remarks
Quantity
Round
Metal
LA9Z-SM61 1
(aluminum color)
Round
Plastic
LA9Z-S61B 1
(black)
Plastic
LA9Z-S71B 1
(black)
Rectangular
Plastic
LA9Z-S81B 1
(black)
Round LA9Z-DS6 1
Rectangular LA9Z-DS8 1
Note: Terminal covers and maintenance parts for L6/A6 other than those shown above can also be used, except switch guard (AL-K) and rub-
ber boot (AL-D).
(06/11/10)
20
Flush Silhouette L6/A6 Series Control Units ø16
Plastic
LA9Z-BS6 1
(black)
Square
Rectangular
Plastic
LA9Z-BS8 1
(black)
Dimensions
Flush Bezel Flush Bezel with Control Units
Mounting Flush
Plastic • L6 Series • A6 Series
Bracket Gasket Bezel Metal
Panel Thickness 0.5 to 5 Panel Thickness 0.5 to 5
• Round
ø21.4
22.6
14.8
ø 20
8 8
ø1 ø1
4
0.9
ø2
ø2
0.8
9.8 8.5 2 1
9 43 2
8 29 2
• Square
21.4
24
18
20
• Selector Switch
• Illuminated Selector • Key Selector • Lever Switch
Switch Switch
• Rectangular
21.4
20
24
18
24 2 2
2
30 A B
17
27.4
23
26
20.2 +0.2
.1
– 0.1
+
– 0.1
.2
24∗
30∗
24∗ 24∗
(06/11/10)
21
ø16 Flush Silhouette L6/A6 Series Accessories
47.5
33.1
33.1
30
24
Mounting holes are the
1 same size as rectangular
9 43 5.4 8 29 5.4 30 flush bezels.
24
24
30.3 2 30
Rubber Boot
Panel Thickness 0.5 to 5
7
ø2
1
6
27
6
10.5 20.5 4 27 33
9 43
L6 Series
Solder/Tab Terminal
Safety Precautions
• Turn off the power to the control units before starting instal- • For wiring, use wires of a proper size to meet the voltage
lation, removal, wiring, maintenance, and inspection of the and current requirements and solder correctly. Improper
products. Failure to turn power off may cause electrical soldering may cause overheating and fire hazard. Also,
shocks or fire hazard. when using tab terminals, use appropriate quick connect
receptacles.
• To avoid burning your hand, use the lamp holder tool when
replacing lamps.
(06/11/10)
22
Flush Silhouette L6/A6 Series Accessories ø16
Instructions
Panel Mounting of Flush Installing the Rubber Boot Replacing the Lens
Bezels Attach the rubber boot and the flush • Removing
• L6 series bezel to the operator. Then insert the Remove the lens assembly (lens,
1. Remove the contact block from the assembly into the panel. Attach the marking plate, and lens holder) from
operator. Remove the locking ring mounting bracket and tighten the lock- the operator by holding the lens
and anti-rotation ring. To remove the ing ring. Tighten the locking ring to the removal tool (MT-101) and pull out.
operator from the contact block, turn recommended tightening torque of
the locking lever in the direction 0.88N·m. (Do not use the anti-rotation
opposite to the arrow on the hous- ring supplied with the operator.)
ing.
Anti-rotation ring supplied
2. Attach the flush bezel to the opera- with the operator
Flush Bezel/
L6/A6 Operator Flush Bezel with Switch Guard Incorrect
Install
• A6 series
1. Remove the locking ring and anti-
rotation ring from the operator.
2. Attach the flush bezel to the opera-
tor. Then insert the assembly into
the panel. Attach the mounting
bracket and tighten the locking ring.
(Do not use the anti-rotation ring
supplied with the operator.)
For round flush bezels, place the
projection on the bezel to the groove
on the TOP side of the operator and
mount onto the panel.
(06/11/10)
23
ø12 A2 Series Miniature Control Units
Short 22-mm-long body miniature control unit series with bright LED illumination
face and snap-action switching.
• Available in enclosed (IP40) and waterproof (IP65), and oiltight
types.
• 12-mm mounting holes
• All series have terminals on the same plane.
• UL recognized, CSA certified
Weight Illumination
Unit
Between live part and ground:
2,000V AC, 1 minute
AL2M-M11: 4g Operating extremes:
Vibration Resistance
Weight (approx.) AL2M-P1: 4g 5 to 55 Hz, amplitude 0.75 mm
AB2M-M1: 4g Damage limits: 500 m/s2 (50G)
Shock Resistance
Operating extremes: 200 m/s2 (20G)
Mechanical Durability Momentary: 200,000 operations
(minimum operations) Maintained: 100,000 operations
Momentary: 100,000 operations
Electrical Durability Maintained: 50,000 operations
(minimum operations)
(Switching frequency 1200 operations/h)
Enclosed (IP40)
Degree of Protection
Waterproof, dust-tight (IP65)
Note: When LED lamps are used on voltages other than the above, external resistor value R is determined by the following formula:
R = (operating voltage – Vf) / If
• LED lamps do not have a current-limiting resistor, and external resistors of recommended values for each voltage must be
provided. Connect a current-limiting resistor in series, otherwise LED lamps will be damaged. Because no protection diode (+) (–)
is contained, ensure the correct polarity is observed.
Current
Lamp Lamp
Limiting
Terminal (+) Terminal (–)
Resistor
(06/11/10)
24
A2 Series Miniature Control Units ø12
Dimensions
Panel Thickness 0.5 to 6
Rubber Gasket
Rectangular Square Round
Locking Ring
(TOP) (TOP) (TOP)
Terminal Width 1.8×0.4t
2.8
9.2
ø14
14
2.8
7 22 9 18 9 c14 ø14
NC1 NC2
(06/11/10)
25
ø12 A2 Series Miniature Control Units
AB2 Pushbuttons
Dimensions
Panel Thickness 0.5 to 6
Rubber Gasket
Locking Ring Rectangular Square Round
(TOP) (TOP) (TOP)
2.8
14
2.8
NO1 NO2
14 min.
14 min.
C1 C2
(06/11/10)
26
A2 Series Miniature Control Units ø12
Accessories
Ordering Package
Shape Material Type No. Dimensions (mm)
Type No. Quantity
Locking Ring Wrench • Used to tighten the locking ring when
installing the A2 control units into a
ø14 Metal
MT-002 MT-002 1 panel.
(nickel-plated brass)
• Tighten the locking ring to a torque of
60 0.78 N·m maximum.
Lens Removal Tool
60
Lamp Holder Tool
Rubber OR-66 OR-66 1 • Used to remove and install LED lamps.
70
Switch Guard • Degree of protection:
For round/ IP40
AL-K2 AL-K2 1
square Unit • Used to protect
90° open pushbuttons from
For rectangular inadvertent operation. (remains
AL-KH2 AL-KH2 1 • See page 28 for 90° open)
unit
dimensions.
Socket
Solder Terminal AL-C2 AL-C2 1
• Snaps on the rear of the A2 series
control units.
(see page 28 for dimensions)
PC Board Terminal AL-C2V AL-C2V 1
Socket with Built-in Resistor 5V DC AL-C21 AL-C21 1 Blue • A current limiting resistor is
contained, eliminating the
6V DC AL-C22 AL-C22 1 Green need for external resistors.
Solder
Socket Bottom Color
Terminal • When using the socket with a
12V DC AL-C23 AL-C23 1 Yellow built-in resistor, make sure
that the continuous current is
24V DC AL-C24 AL-C24 1 Red 1A maximum and the
operating temperature is –25
5V DC AL-C21V AL-C21V 1 Blue to +40°C. In collective
mounting, keep center-to
6V DC AL-C22V AL-C22V 1 Green center-spacing of 20 mm or
PC Board more between adjacent units
Terminal in consideration of built-in
12V DC AL-C23V AL-C23V 1 Yellow resistor heating.
• See page 28 for dimensions.
24V DC AL-C24V AL-C24V 1 Red
Terminal Cover • When wiring the terminals, insert the
lead wires into the terminal cover holes
Nylon AL-V2 AL-V2PN10 10 before soldering.
• Terminal cover is not attached and must
be ordered separately.
Dust Cover • When mounting the control units with
For round units AL-D2 AL-D2 1 the dust covers installed, refer to
mounting hole layout on page 29.
• Operating temperature: –10 to +55°C
For square units AL-DQ2 AL-DQ2 1 • Material
Front part: Elastomer (transparent)
Rear part: Polypropylene (black)
For rectangular units AL-DH2 AL-DH2 1 • See page 29 for dimensions and
mounting hole layout.
Mounting Hole Plug
Nitryl rubber (black) AL-B2 AL-B2PN05 5 • Degree of protection: IP65
(06/11/10)
27
ø12 A2 Series Miniature Control Units
Maintenance Parts
Package
Shape Specification Type No. Ordering Type No. Color Code ➀➁
Quantity
Marking Plate Round AL2M-W AL2M-WPN05
Dimensions
• Switch Guard
For Round/Square Units (AL-K2) Panel Thickness For Rectangular Units (AL-KH2) Panel Thickness
14 26.5 0.5 to 5 18 26.5 0.5 to 5
11
11
19.5
19.5
8.5
8.5
22.5 min.
22.5 min.
15 min.
19 min.
2.8
NC1 NC2
10.5
10.5
NO1 NO2
2.8
2.8
C1 C2
17 6.5 13 17 4.5 +0.2
8-1.0 0 Holes Lamp Terminal (–)
Solder Terminal Type PC Board Terminal Panel Cut-out
(AL-C2) (AL-C2V) Bottom View
36 1 6 36 1 6
2.8
2.8
6.5 7.3
6.5 7.3
5.3 4.9
10.5
10.2
2.8
2.8
Solder Terminal Type with Built-in Resistor PC Board Terminal Type Panel Cut-out
(AL-C2 c ) with Built-in Resistor (AL-C2 c V) Bottom View
All dimensions in mm.
(06/11/10)
28
A2 Series Miniature Control Units ø12
Dimensions
• Terminal Cover
(AL-V2) 17.3
Note: When wiring the terminals, insert the lead wires into the
ø12.8
terminal cover holes before soldering.
33.5
• Dust Cover
For Round Units For Square Units For Rectangular Units Mounting Hole Centers
(AL-D2) (AL-DQ2) (AL-DH2) (Round Units, Square Units)
ø20 c 20 24 ø12
20 min.
20
20 min.
12
12
12
0.3
6.5
0.3
6.5
20 min.
24 min.
(06/11/10)
29
ø12 A2 Series Miniature Control Units
Safety Precautions
• Turn off the power to A series control units before starting • For wiring, use wires of a proper gauge to meet the voltage and
installation, removal, wiring, maintenance, and inspection of the current requirements. Failure to tighten terminal screws may
control units. Failure to turn power off may cause electrical shocks cause overheating and create a fire hazard.
or fire hazard.
• To avoid burning your hand, use the lamp holder tool when
replacing lamps.
Operating Instructions
Engraving
Operating Voltage of LED Lamps
Area The operating voltage is measured at complete DC. When using a
Color Lens Marking Lens Holder
Plate pulsating voltage such as a full-wave rectification voltage, keep
peak currents within the forward current If. Peak currents exceeding
• Installation the If may shorten the LED lamp life.
Place the marking plate on the lens holder in the correct direction,
and press the color lens onto the lens holder to engage the latches. Other Notes
Put the spring on the lens holder and insert the lens holder into the
• Close Proximity Mounting
housing in the correct direction.
When mounting pilot lights or illuminated pushbuttons collectively or
• Installing Non-illuminated Button lighting them continuously, heat may cause the ambient
Non-illuminated pushbuttons contain a marking plate like temperature to rise above the rated operating temperature. When
illuminated units. Be sure to install the marking plate when replacing the mounting panel is not made of metal or when the control units
the button. are mounted in an enclosed panel, provide for ventilation or lower
the operating voltage.
Replacing the LED Lamp • Replacement of Buttons (Illuminated/Non-illuminated)
• Removal Do not replace buttons of maintained action units while the button is
Use the lamp holder tool (OR-66) to remove lamps. Do not use in the locked position. Replacing the button in the locked position
pliers. may damage the internal mechanism. Be sure to release the button
before replacing.
• Installation
• Operating and Storage Environment
Use the lamp holder tool (OR-66) to install lamps. Note the correct
side of the tool for removal or installation. 1. Make sure that the operating/storage temperature and humidity
are within the ratings.
Lamp Holder Tool 2. Do not use enclosed type units (IP40) in an environment subject
OR-66 (ø8, ø10, ø12 series)
to oil, water or dust accumulation. In such an area, use the
waterproof/oiltight units (IP65).
(06/11/10)
30
ø10 A1 Series Miniature Control Units
Short 22-mm-long body miniature control unit series with LED illumination face
and snap-action switching.
• Bright and clear LED illumination.
• 10-mm mounting holes
• All series have terminals on the same plane.
• UL recognized, CSA certified
Resistive Load – 1.0A 0.5A Insulation Resistance 100 MΩ minimum (500V DC megger)
AC 50/60 Hz Between live and dead metal parts:
Inductive Load – 0.7A 0.5A
2,000V AC, 1 minute
Resistive Load 1.0A 0.2A – Between terminals of different poles:
DC 2,000V AC, 1 minute
Inductive Load 0.7A 0.1A – Switch Unit
Dielectric Between terminals of the same pole:
Contact Material Silver Strength 1,000V AC, 1 minute
Between contact and lamp terminals:
• Minimum applicable load: 5V AC/DC, 3 mA 1,500V AC, 1 minute
(applicable range may vary with operating conditions and load types)
Illumination Between live part and ground:
Unit 2,000V AC, 1 minute
Weight Operating extremes:
Vibration Resistance
AL1M-M11: 3g 5 to 55 Hz, amplitude 0.75 mm
Weight (approx.) AL1M-P1: 3g Damage limits: 500 m/s2 (50G)
Shock Resistance
Operating extremes: 200 m/s2 (20G)
AB1M-M1: 3g
Mechanical Durability Momentary: 200,000 operations
(minimum operations) Maintained: 100,000 operations
Momentary: 100,000 operations
Electrical Durability
Maintained: 50,000 operations
(minimum operations)
(Switching frequency 1200 operations/h)
Degree of Protection Enclosed (IP40)
Note: When LED lamps are used on voltages other than the above, external resistor value R is determined by the following formula:
R = (operating voltage – Vf) / If
• LED lamps do not have a current-limiting resistor, and external resistors of recommended values for each voltage
must be provided. Connect a current-limiting resistor in series, otherwise LED lamps will be damaged. Because (+) (–)
no protection diode is contained, ensure the correct polarity is observed.
Current
Lamp Lamp
Limiting
Terminal (+) Terminal (–)
Resistor
(06/11/10)
31
ø10 A1 Series Miniature Control Units
Dimensions
Panel Thickness 0.5 to 6
ø12
2.8
NO
12 min.
12 min.
COM
Lamp Lamp
Terminal (+) Terminal (–)
12 min. 16 min.
(06/11/10)
32
A1 Series Miniature Control Units ø10
AB1 Pushbuttons
Type No.
Shape Button Type Operation Type Contact Color Code ➀➁
IP40
Round B black
AB1M Momentary SPDT AB1M-M1➀ G: green
R: red
Button S: blue
Maintained SPDT AB1M-A1➀ W: white
Y: yellow
Dimensions
Panel Thickness 0.5 to 6
Locking Ring
Rectangular Square Round
(TOP) (TOP) (TOP)
2.8
NO
12 min.
12 min.
COM
12 min. 16 min.
(06/11/10)
33
ø10 A1 Series Miniature Control Units
Accessories
Ordering Package
Shape Material Type No. Dimensions (mm)
Type No. Quantity
Locking Ring Wrench • Used to tighten the locking ring when
installing the A1 control units into a
ø12 Metal panel.
MT-003 MT-003 1
(nickel-plated brass)
• Tighten the locking ring to a torque of
60 0.29 N·m maximum.
Lens Removal Tool
60
70
Terminal Cover
• When wiring the terminals, insert the
lead wires into the terminal cover holes
Nylon AL-V1 AL-V1PN10 10 before soldering.
• Terminal cover is not attached and must
be ordered separately.
ø12
2
(06/11/10)
34
A1 Series Miniature Control Units ø10
Maintenance Parts
Package
Shape Type No. Ordering Type No. Color Code ➀➁
Quantity
Marking Plate Round AL1M-W AL1M-WPN05
Square AL1Q-W AL1Q-WPN05 5 • White
Dimensions
• Switch Guard
10
17.5
17.5
7.5
7.5
20.5 min.
20.5 min.
12.5
13 min. 17 min.
2.8
NC
NO
COM
2.8
2.8
17 5 11 17 3 Lamp Lamp
+0.2
5-1.0 0 Holes Terminal (+) Terminal (–)
Note: When wiring the terminals, insert the lead wires into the
ø10.8
(06/11/10)
35
ø10 A1 Series Miniature Control Units
Safety Precautions
• Turn off the power to A series control units before starting • For wiring, use wires of a proper gauge to meet the voltage and
installation, removal, wiring, maintenance, and inspection of the current requirements. Failure to tighten terminal screws may
control units. Failure to turn power off may cause electrical shocks cause overheating and create a fire hazard.
or fire hazard.
• To avoid burning your hand, use the lamp holder tool when
replacing lamps.
Operating Instructions
• Installation
Place the marking plate on the lens holder in the correct direction,
Other Notes
and press the color lens onto the lens holder to engage the latches. • Close Proximity Mounting
Put the spring on the lens holder and insert the lens holder into the When mounting pilot lights or illuminated pushbuttons collectively or
housing in the correct direction. lighting them continuously, heat may cause the ambient
temperature to rise above the rated operating temperature. When
• Installing Non-illuminated Button the mounting panel is not made of metal or when the control units
Non-illuminated pushbuttons contain a marking plate like illumi- are mounted in an enclosed panel, provide for ventilation or lower
nated units. Be sure to install the marking plate when replacing the the operating voltage.
button.
• Replacement of Buttons (Illuminated/Non-illuminated)
Do not replace buttons of maintained action units while the button is
Replacing the LED Lamp in the locked position. Replacing the button in the locked position
• Removal may damage the internal mechanism. Be sure to release the button
before replacing.
Use the lamp holder tool (OR-66) to remove lamps. Do not use
pliers. • Operating and Storage Environment
• Installation 1. Make sure that the operating/storage temperature and humidity
are within the ratings.
Use the lamp holder tool (OR-66) to install lamps. Note the correct
2. Do not use enclosed type units in an environment subject to oil,
side of the tool for removal or installation.
water or dust accumulation.
Lamp Holder Tool • Microswitch Contacts
OR-66 (ø8, ø10, ø12 series)
Do not connect NO and NC contacts of the microswitch to different
voltages or different power sources to prevent a dead short-circuit.
Panel Mounting
When mounting the control units into a panel, use the optional
locking ring wrench (MT-003) to tighten the locking ring. Do not use
pliers. Tightening torque must not exceed 0.29 N·m. Excessive
tightening will damage the locking ring.
(06/11/10)
36
ø8 A8 Series Miniature Control Units
Short 22-mm-long body miniature control unit series with LED illumination face
and snap-action switching.
• Bright and clear LED illumination.
• 8-mm mounting holes
• All series have terminals on the same plane.
• UL recognized, CSA certified
Note: When LED lamps are used on voltages other than the above, external resistor value R is determined by the following formula:
R = (operating voltage – Vf) / If
• LED lamps do not have a current-limiting resistor, and external resistors of recommended values for each voltage must
be provided. Connect a current-limiting resistor in series, otherwise LED lamps will be damaged. Because no protection (+) (–)
diode is contained, ensure the correct polarity is observed.
Current
Lamp Lamp
Limiting
Terminal (+) Terminal (–)
Resistor
(06/11/10)
37
ø8 A8 Series Miniature Control Units
Dimensions
Panel Thickness 0.5 to 6
1.8 × 0.4t
9
ø9
2.5
5 5.5 5.5 12 c9 ø9
7 22 9
NO
9 min.
9 min.
COM
Lamp Lamp
Terminal (+) Terminal (–)
9 min. 12 min.
(06/11/10)
38
A8 Series Miniature Control Units ø8
AB8 Pushbuttons
Type No.
Shape Button Type Operation Type Contact Color Code ➀➁
IP40
Round B black
AB8M Momentary SPDT AB8M-M1➀ G: green
R: red
Button S: blue
Maintained SPDT AB8M-A1➀ W: white
Y: yellow
Square B black
AB8Q Momentary SPDT AB8Q-M1➀ G: green
R: red
Button S: blue
Maintained SPDT AB8Q-A1➀ W: white
Y: yellow
Rectangular B black
AB8H Momentary SPDT AB8H-M1➀ G: green
R: red
Button S: blue
Maintained SPDT AB8H-A1➀ W: white
Y: yellow
Dimensions
Panel Thickness 0.5 to 6
Locking Ring
Rectangular Square Round
Terminal Width (TOP) (TOP) (TOP)
2.5
1.8 × 0.4t
9
2.5
5.5 5.5 12 c9 ø9
7 22 9
NO
9 min.
9 min.
COM
9 min. 12 min.
(06/11/10)
39
ø8 A8 Series Miniature Control Units
Accessories
Ordering Package
Shape Material Type No. Dimensions (mm)
Type No. Quantity
Locking Ring Wrench • Used to tighten the locking ring when
installing the A8 series control units into
ø9 Metal (nickel-plated brass) MT-004 MT-004 1 a panel.
• Tighten the locking ring to a torque of
60 0.29 N·m maximum.
Lens Removal Tool
Stainless Steel MT-101 MT-101 1 • Used to remove the lens and button.
60
Socket
Solder Terminal AL-C8 AL-C8 1
• Snaps on the rear of the A8 series
control units.
(see page 41 for dimensions)
PC Board Terminal AL-C8V AL-C8V 1
Terminal Cover
• When wiring the terminals, insert the
lead wires into the terminal cover holes
Nylon AL-V8 AL-V8PN10 10 before soldering.
• Terminal cover is not attached and must
be ordered separately.
(06/11/10)
40
A8 Series Miniature Control Units ø8
Maintenance Parts
Package
Shape Type No. Ordering Type No. Color Code ➀➁
Quantity
Marking Plate Round AL8M-W AL8M-WPN05
Square AL8Q-W AL8Q-WPN05 5 • White
Dimensions
• Switch Guard
8.5
14.5
14.5
17.5 min.
6
17.5 min.
12.5
11 min. 13 min.
NC
NO
2.5
COM
Lamp Lamp
2.5
17 5 8.8 17 3 +0.2
5-1.0 0 Holes Terminal (+) Terminal (–)
Note: When wiring the terminals, insert the lead wires into the
terminal cover holes before soldering.
ø9.1
33.5
(06/11/10)
41
ø8 A8 Series Miniature Control Units
Safety Precautions
• Turn off the power to A series control units before starting • For wiring, use wires of a proper size to meet the voltage and
installation, removal, wiring, maintenance, and inspection of the current requirements. Failure to tighten terminal screws may
control units. Failure to turn power off may cause electrical shocks cause overheating and create a fire hazard.
or fire hazard.
• To avoid burning your hand, use the lamp holder tool when
replacing lamps.
Operating Instructions
(06/11/10)
42
A Series Miniature Control Units
(06/11/10)
43
Specifications and other descriptions in this catalog are subject to change without notice.
7-31, Nishi-Miyahara 1-Chome, Yodogawa-ku, Osaka 532-8550, Japan
Tel: +81-6-6398-2571, Fax: +81-6-6392-9731
E-mail: products@idec.co.jp
IDEC CORPORATION (USA) IDEC ELEKTROTECHNIK GmbH IDEC IZUMI (H.K.) CO., LTD.
1175 Elko Drive, Sunnyvale, CA 94089-2209, USA Wendenstrasse 331, 20537 Hamburg, Germany Unit 1505-07, DCH Commercial Centre No. 25,
Tel: +1-408-747-0550 / (800) 262-IDEC (4332) Tel: +49-40-25 30 54 - 0, Fax: +49-40-25 30 54 - 24 Westlands Road, Quarry Bay, Hong Kong
Fax: +1-408-744-9055 / (800) 635-6246 E-mail: service@idec.de Tel: +852-2803-8989, Fax: +852-2565-0171
E-mail: opencontact@idec.com E-mail: info@hk.idec.com
IDEC (SHANGHAI) CORPORATION
IDEC CANADA LIMITED Room 608-609, 6F, Gangtai Plaza, No. 700, IDEC TAIWAN CORPORATION
Unit 22-151, Brunel Road Mississauga, Ontario, Yan'an East Road, Shanghai 200001, P.R.C. 8F-1, No. 79, Hsin Tai Wu Road, Sec. 1,
L4Z 1X3, Canada Tel: +86-21-5353-1000, Fax: +86-21-5353-1263 Hsi-Chih, Taipei County, Taiwan
Tel: +1-905-890-8561, Toll Free: (888) 317-4332 E-mail: idec@cn.idec.com Tel: +886-2-2698-3929, Fax: +886-2-2698-3931
Fax: +1-905-890-8562 E-mail: service@idectwn.com.tw
E-mail: sales@ca.idec.com
IDEC (SHANGHAI) CORPORATION
Beijing Office IDEC IZUMI ASIA PTE. LTD.
IDEC AUSTRALIA PTY. LTD. Unit 1002, No. 10 Kuntai Building, Zhaowai Dajie, No. 31, Tannery Lane #05-01, Dragon Land
2/3 Macro Court, Rowville, Victoria 3178, Australia Zhao Yang District, Beijing, 100020, P.R.C. Building, Singapore 347788
Tel: +61-3-9763-3244, Toll Free: 1800-68-4332 Tel: +86-10-6599-5541, Fax: +86-10-6599-5540 Tel: +65-6746-1155, Fax: +65-6844-5995
Fax: +61-3-9763-3255 E-mail: info@sg.idec.com
E-mail: sales@au.idec.com IDEC (SHENZHEN) CORPORATION
Unit AB-3B2, Tian Xiang Building, Tian’an Cyber Park,
IDEC ELECTRONICS LIMITED Fu Tian District, Shenzhen, Guang Dong 518040, P.R.C.
Unit 2, Beechwood, Chineham Business Park, Tel: +86-755-8356-2977, Fax: +86-755-8356-2944
Basingstoke, Hampshire RG24 8WA, UK
Tel: +44-1256-321000, Fax: +44-1256-327755
www.idec.com E-mail: sales@uk.idec.com