Interlab Catalogue 2020
Interlab Catalogue 2020
sales
and service of high performance quality control instruments for the testing of petroleum and petrochemical products.
Intrinsic to everything we do is total customer satisfaction. Designed with the most advanced technologies, with eralytics TM analyzers
you are assured of the best in quality, best in performance and best in reliability. We continually develop new applications to assist
you in enhancing production efficiency and quality.
Eralytics products :
Vapor Pressure Testing
Flash Point Testing
FTIR Fuel Analysis
FTIR Oil Analysis
Oil In Water Testing
VAPOR PRESSURE
Vapor pressure testing at its best - The vapor pressure analyzer for
virtually all types of fuel, from gasoline to LPG, that also handles crude oil,
and takes tests in full compliance with the latest ASTM and EN ISO standards.
With its unmatched precision and measuring stability (r = 0.3 kPa, R = 0.7
kPa) it is the preferred analyzer in laboratories across the world.
ERAVAP
SPECIFICATIONS :
Available test methods : ASTM D5188, D5191, D6377, D6378, D6897; EN 13016; JIS K2258-2; GOST 52340
Temperature range : 0 to 120°C (32 to 248°F); Peltier technology, no external cooling necessary
Precision Repeatability: r = 0.3 kPa, Reproducibility: R = 0.7 kPa
Sample introduction : Automated via built in piston, no external vacuum pump required
Shaker motor : Built-in shaker motor for fast crude oil (D6377) & T(V/L) (D5188) measurements D5191 & D5188 Speed test
DVPE & T(V/L=20) measurement of gasoline at the push-of-a-button
Auto sampler : Optional 10 position auto sampler – directly attached!
Quality-check tracking : Statistical analysis (ASTM D6299) with graphics directly on the large touch screen
ERACHECK
SPECIFICATIONS :
Available test methods : Measurement in full compliance with ASTM D7678 Excellent correlation to ASTM D3921, D7066,
D4281; EPA 1664A; ISO 11046, ISO 9377
Technology : Innovative quantum cascade laser infra-red (QCL-IR) measuring technology
Solvent : Safe and low-cost extraction with non-polluting cyclohexane or cyclopentane
Measuring range : 0.5 to 2000 ppm (repeatability < 1 ppm)
FUEL ANALYSIS
Spectral fuel analysis in seconds - The portable FTIR spectrometer
that is fully automated and multi-fuel capable. With its patented rugged
design, it is perfect for fast gasoline, diesel & jet fuel analysis, delivering
precise results for over 40 fuel parameters, like aromatics incl. benzene (ASTM
D6277), oxygenates (ASTM D5845), FAME (EN14078) and many fuel
properties like Octane, Cetane, Density, Distillation, Vapor Pressure, etc.
ERASPEC
SPECIFICATIONS :
Available test methods : ASTM D5845, D6277; EN238, EN14078 excellent correlation to D86, D323, D613, D976, D2699, D2700,
D4814, D5191, D6378
Spectrometer type : NIR/MID-FTIR interferometer (16.384 data points; scanning range: 600 to 7000 cm-1)
Measuring cell : Multi-position cell for Gasoline, Diesel and Jet fuel analysis with a single analyzer
Warm-up / Measuring time : 30 seconds / 60 seconds
Auto sampler : Optional 10 position auto sampler – directly attached!
FLASH POINT ANALYSIS
The safe side of flashpoint testing - The patented PBT - Peltier Boost
Technology TM makes the ERAFLASH the first and only flashpoint tester on the
market to cover the wide temperature range of -25 to 420°C in a single
analyzer. Its small sample size and the continuously closed measuring
chamber (ASTM D6450 & D7094) guarantee maximum safety and speed at
minimum costs..
ERAFLASH
ERAFLASH S10 the brand new 10 position autosampler for
unattended flash point testing is now available. It combines the safest
way of flash point testing with the comfort of unattented
measurements of up to 10 flash point samples. All without an
uncomfortable feeling due to safety concerns or fire hazards. It
combines all well-known features such as the widest temperature
range from -25°C to 420°C of ERAFLASH with the unique 10 position
autosampler feature.
ERAFLASH S10
SPECIFICATIONS :
Available test methods : ASTM D6450 & D7094
Pre-programmed correlation methods : ASTM D93c (Pensky Martens Closed Cup), ASTM D56c (TAG Closed Cup) EN ISO
3679c & 3680c, ASTM D3828c (Small Scale Closed Cup)
PBT - Peltier Boost Technology : -25 to 420°C (-13 to 788°F) with a single analyzer
Sample throughput : Up to 12 samples per hour
Sample volume : 1 ml (ASTM D6450); 2 ml (ASTM D7094)
Combustion Graphics : Display of combustion characteristics for contamination analysis
Temperature Stability : 0.1°C (0.2°F)
Alarm Tracking : All alarm messages are stored in the database together with the result
Temperature Range : 0 to 200°C (32 to 390°F) stand alone. No external cooling is required. -25 to 0°C (-13 to 32°F) with water
cooling / chiller 200 to 420°C (390 to 788°F) with optional High Temperature Module (EF01-HTM)
Speed Tests : Flash/no flash and fast screening test programs
Normalab core activity is the design and manufacture of testing instruments, dedicated to quality control in laboratories for various
industries including: petroleum, petrochemicals, cosmetics, pharmaceutical,food and beverage, bio fuels.
In 2008, the Normalab Analis company, established for years in the field of petroleum testing instruments became Normalab and
changed significantly in its organisation to improve development of new products based on user’s needs.
SPECIFICATIONS :
Test Temperature Range : Ambient to 410°C
Flash point detection by thermocouple
Electric and Gas ignition
Regulated electric ignitor
Integrated barometric correction
6,4 inch High Definition screen
Capacitive touch screen
Standard Methods: A, B, C
Fast heating and cooling
Heating Rate : 0 - 15°C
Stirring Speed : 50 - 300 RPM (± 3 RPM)
Windows 8 operating system
Reporting : PDF, Excel, Words, email, LIMS
Automatic fire extinguisher
Integrated Hydrocarbon sensor
Dimensions : (W) 260 x (D) 460 x (H) 185 mm
SPECIFICATIONS :
Temperature measuring range 0 to 500°C
Automatic adjustment of heating element position
Storage temperature -20 to +55°C
Use temperature +15 to +30°C
Touch pad Protected by replaceable film
Windows Based Software
Automated Fire Extinguisher
Automatic Fire Detection
Built-in Cooling System
VISCOSITY BATH NVB CLASSIC
SPECIFICATIONS :
This test method specifies a procedure for Temperature range : ambient to 230°C
the determination of the kinematic Bath volume : 40 L
viscosity, of liquid petroleum products, both Setting ± : 0.1°C
transparent and opaque, by measuring the Heaters : 3
time for a volume of liquid to flow under Offset : 0.01°C
gravity through a calibrated glass capillary Stability * ± : 0.01°k
viscometer. Conform to ASTM D445 - ISO Inside bath : stainless steel 304, PTFE
3104 - IP71 - DIN 51366 Number of lids : 4 + 3 or 4 + 4 L
Bath volume : 40 L
SOFTENING POINT NBA ±440
Setting : 0.1°C
Heaters : 3
This test method covers the determination Offset : 0.01°C
SPECIFICATIONS :
of the softening point of bitumen in the Stability
Controlled* ± heating
: 0.01°k rate and stirring speeds
range from 30 to 157°C (86 to 315°F) Inside bath : stainless steel 304, PTFE
Cooling by fan at the end of the test
using the ring-and-ball apparatus immersed Number of lids : 4 + 3 or 4 + 4 L
Waterproof heating element
in distilled water (30 to 80°C), USP
RS232C output
glycerine (above 80 to 157°C), or ethylene
glycol (30 to 110°C). 4 preset of programmable methods available
Standard Method ASTM D 36 - IP 58 - Auto diagnostic
DIN 52011 - ISO EN 1427 - ISO 4625 Data Storage : 200 results
Large display
Automatic detection of softening point by
optical cells
Bath volume : 40 L
Setting ± : 0.1°C
Heaters : 3
Offset : 0.01°C
Stability * ± : 0.01°k
Inside bath : stainless steel 304, PTFE
Number of lids : 4 + 3 or 4 + 4 L
PILODIST® offers a long-established and extensive experience, supported by technical know-how and competence which
originates from the world renowned company, founded by Mr. W.G.Fischer (see words of welcome). Today the Fischer family
continues to support PILODIST giving the company a position of unrivalled excellence.
PILODIST® can upgrade the majority of crude oil distillation systems that are currently in use globally, all work is undertak en strictly
in conformance with ASTM standards. Our upgrade service is not limited to PILODIST® – systems as our technicians have the ability
to work on several makes of distillation systems and the service we provide includes replacement/upgrade of individual components.
We are pleased to offer advice regarding the cost effectiveness of maintaining existing systems and on the benefits of upgrade that
will allow enhanced performance using latest process electronics combined with control and evaluation software.
PETRODIST 100 CC
SPECIFICATIONS :
● Available flask sizes : 2, 4, 6, 10, 20 L
● Operating temperature : up to 350° C (660° F)
● Operating pressure : vacuum down to 1 torr
● Final cut temperature : up to 400°C AET (750°F)
● Power consumption : 6000 W (without options)
● Max. ambient temperature : 25° C
● Mains supply : 230 / 400 V, 50 Hz, 5-wire system, 3-phase + N + PE
● Dimensions (w x h x d) : 2.60 x 3.50 x 0.90 m
Fully Automatic ASTM D5236
According to ASTM D-5236 (Standard Test Method for
Distillation of Heavy Hydrocarbon Mixtures, Vacuum Potstill
Method). The system is designed for unattended operation (during
the distillation), the safety devices are designed accordingly. Data
station for data input as well as for display and print out of all
operation parameters, distillation results and distillation curve. The
distillation ensues automatically from the start to the pre-selected
or detected end point.
The distillate volume is automatically recorded by means of an
integrated volume follower system. The volume is measured
separately on every individual receiver. The unit does not contain
any intermediate receiver i.e.: to avoid reblend of the distillate. The
volume calculation is expressed as percentage corresponding to the
weight and the volume of the flask charge or total recovery. The
distillation curve is printed out in weight and volume percent.
The fraction changes are carried out automatically, alternatively
according to a pre-selected boiling temperature or distillate volume
or when the receivers are filled up. The vacuum-tight fraction
collector contains 12 receivers with a capacity related to the flask
size. The boil up rate is controlled according to a pre-selected
distillation rate in ml/min. An accurate vacuum control guarantees
the required stability of the distillation pressure.
SPECIFICATIONS :
● Available flask sizes : 2, 4, 6, 10, 20 L
● Receiver capacity : 12 x 500 ml (24x250 ml upon request)
● Operating temperature : up to 400° C (750° F)
● Operating pressure : vacuum down to 0.1 Torr
● Final cut temperature : up to 565° C AET (1050° F)
● Power consumption : 5000 W
● Max. ambient temperature : 25° C
PETRODIST 200 CC ● Mains supply : 230 / 400 V, 50 Hz,
● Dimensions (w x h x d) : 1.60 x 2.20 x 0.90 m
SPECIFICATIONS :
● Flask size : 500 ml
● Flask charge : 200 ml
● Operating temperature : up to 400° C (750° F) PETRODIST 300 CC
● Operating pressure : Vacuum down to 1 Torr
● Final cut temperature : up to 550° C AET (1020° F)
● Power consumption : 3500 W (without options)
● Max. ambient temperature : 25° C
● Mains supply : 230 V, 50 Hz
● Dimensions (w x h x d) : approx 0.65 x 0.64 x 0.96 m
Fully Automatic Combination ASTM D2892 & D5236
PETRODIST 400 CC
Turn key processor controlled and combined crude oil distillation system for automatic operation according to ASTM D-2892
(TBP) and ASTM D-5236 (Potstill)
The system enables to perform TBP- and Potstill - distillations of various crude samples according to the a. m. ASTM-
standards. Laboratory design incl. protective sheathing and integrated control system, with safety system. The system is micro
processor controlled with automatic fraction collector and direct automatic distillation flow rate control. The fraction/receiver
changes are automatically performed according to preselected cut temperatures or in case of receiver overfilling. The fraction
collector is equipped with 12 receivers. The final data and the TBP-curve in wt% and vol% are printed out after reweighing the
residue. The fraction collector, vacuum supply, cryo/ thermostat and data station are used for both units. The unit requires
water, nitrogen, compressed air and electricity. Dry ice or liquid nitrogen is required for cold traps.
The combination system consists of two separate distillation systems. Both systems are alternatively operated by one central
control system, Vacuum, cooling, fraction collector and evaluation system. The system has proved to be reliable in practical
operation, as the non-used Equipment is constantly available for the preparation of the next following distillation. The no load
period time of the plant is very short. The combined unit PETRODIST 400 consists of a basis system for the assembly of all parts.
All specific electrical, mechanical and pneumatically control elements are mounted in a frame. The integrated PILODIST control
system with a computer control unit and all other necessary components for automatic operation are installed.
GR Scientific headquarters are based in the stunning country English Heritage Estate of Wrest Park located in Silsoe, Bedfordshire,
UK. We are specialist company manufacturing and supplying laboratory instruments for the Oil and Petrochemical industries since the
early 1980’s. Our technical expertise and commitment in the supply of instrumentation for electrochemical applications is backed up
by our expert technical and service support team providing a personal touch to your experience with us.
AQUAMAX KF PLUS
SPECIFICATIONS :
● Titration vessel: Low Drift Cell design, no grease or PTFE sleeves required
● Measuring range: Possible 1μg - 200mg water, Typical 1μg - 10mg water
● Moisture range: 1ppm - 100% water
● Max. sensitivity: 0.1μg
● Max. titration speed: 2.24 mg per minute
● Precision: 10-100μg ± 3μg, 100μg-1mg ±3μg, above 1mg ±0.3%
● Display: 40 character alphanumeric backlit LCD
● Printer: 42 character high speed thermal printer
VOLUMETRIC TITRATOR
Water Content determination from 0.1ppm to 100%
Features
• Simple to use – intuitive keypad and function display.
• Easy operation with predefined methods and calculations - perfect for
routine users.
• Programmable – pre-programmed methods installed with editable options.
• 2x 5ml syringes – one for KF reagent and the other for automatic dosing of
water standard (second syringe can also be used different factor reagent or
special reagents for ketones and amines analysis).
• Fully automated system means there is no opening of the titration cell nor
waiting on long conditioning times.
• Results expressed in ppm, mg/l and %.
• Automatic rest cycle (stand-by mode) if not used for 15 minutes.
• Bidirectional connection port to printer, PC or balance with RS232C.
• Compact thermal printer available for GLP compliant paper recording.
• Data logger can store up to 55 analysis results.
SPECIFICATIONS :
AQUAMAX KF VOLUMETRIC • Measuring ranges: From 0.1 mg up to 100% water
• Syringe volume: Standard syringe 5 ml
• Resolution: 1/40000 of syringe volume
• Reproducibility: 10 % of the syringe
• Display: Graphic backlit LCD, 128 x 64 dots
• Accuracy: higher than 10 % of the syringe
• Electrovalve: PTFE and KEL-F
Trace Elemental Instruments B.V. the Netherlands was established with the objective of bringing advanced and innovative technology
in trace elemental analysis to the global laboratory community.
We are the key supplier for trace Elemental laboratory instruments. For Total Nitrogen & Total Sulfur we have introduced a full range
of combustion analyzers and accessories, dedicated to handle all sorts of samples according to ASTM methods and international
standards. In our environmental portfolio we have AOX, TOX, EOX & POX laboratory instruments.
Total Sulfur Conform to ASTM D5453, D6667, D7183, EN 20846
Total Nitrogen Conform to ASTM D4629, D5762, D6069, D7184
TE Instruments has developed the Xplorer-NS, a Total Nitrogen and Total Sulfur combustion analyzer, offering fast, accurate and
precise analysis of liquids, LPG’s, gas and solids. This brand new model is designed to offer standardized and customized solutions
to match both current and future analytical needs, ranging from low ppb’s to high ppm’s.
APPLICATIONS
SPECIFICATION :
• Wear resistant ceramic piston pump with controlled constant fl ow
• Viscosity range up to 200 cSt (pressurised sampling up to 350 cSt;
lube oil system up to 1,000 cSt)
Pressure range:
• Low pressure: from pressureless up to 6 bar (85 psi)
• High pressure: 3-420 bar (6000 psi)
PAMAS Volumetric Sensor: HCB-LD-50/50
Calibration ranges:
• 4-70 μm(c) according to ISO 11171 (standard calibration)
• 1-100 μm according to ISO 4402 (optional calibration)
Max. particle concentration:
• 24.000 P/ml at a flow rate of 25 ml/min and a coincidence rate of 7.8%
Counter:
• 8-channel particle counter
• Data printout: 32 column thermo printer
• Data transfer: 8 bit ASCII code through USB port
• Power supply: 90-240 V AC / 50-60 Hz or 12-30 V DC or via integrated battery for up
to three hours operation
• Weight and Size: Approx. 9 kg 300mm x 140mm x 300mm
The PAMAS S40 AVTUR is a portable particle
counting system designed for the aviation fuel
industry. It is equipped with a special AVTUR
mode according to the standard IP577 of the
Energy Institute London. A wear resistant
ceramic piston pump guarantees a constant
flow. With a simple-to-use touch screen user
interface, operation is easy and intuitive. The
system is equipped with an integrated battery
for more than three hours operation and a
data storage of more than 4000
measurements. The samples can be taken
from bottles without pressure or pressurised
up to 6 bar.
SPECIFICATION :
• 8 channel high resolution digital system for analysis
• Fully compliant with the standard method IP 577 of the Energy Institute London
• Fully compliant with the standard DEF STAN 91-91 of the UK Ministry of Defence
• According to ISO 4406 4 μm(c), 6 μm(c), 14 μm(c) based on ISO 11171
• from pressureless to pressurised sampling up to 6 bar
• User-friendly operation using touch screen with graphic display
• Measuring results reported in compliance with IP 577, DEF STAN 91-91, ISO 4406,
NAS 1638, SAE AS 4059, GJB 420 and GOST 17216
• Sampling system: Wear resistant ceramic piston pump with controlled constant fl ow.
• Pressure range: From pressureless up to 6 bar (85 psi)
• Calibration ranges: 4 - 70 μm(c) according to ISO 11171 (standard calibration)
1 - 100 μm according to ISO 4402 (optional calibration)
• Data transfer: 8 bit ASCII code through USB port (57600 baud)
• Data printout: 32 column thermo printer
• Power supply: 90-240 V AC / 50-60 Hz or 12-30 V DC or via integrated battery for up
to 3 hours operation
• Data storage of more than 4000 measurements
In order to satisfy its clients, in 2003 Linetronic Technologies launched a vast and complete range of manual and semi-
automatic analytical instruments onto the market which are conform to the numerous petroleum norms.
SPECIFICATIONS :
- Temperatures: in °C
- Measuring range: +80°C … -80°C
- Resolution: 0.06 °C
- Accuracy: ± 0.1 °C
- Platinum resistance PT100 class A
- Storage capacity :60’000 analysis
- Motor compressors with internal
overload devices
- Thermo-switch for each cooling /
heating jacket
- Printable graphs and results
- The LabLink software is Windows
- Cooling System Integrated gas CFC free motor compressors :
- Single stage (for temperatures up to -40°C / 1)
- Double stage (for temperatures up to -85°C / 2)
- Stand alone version with integrated panel PC :
TFT/LCD 6.5” or 12”
Resolution 640 × 480 262K colours or 1024 × 768 16M colours
- 2 × USB and/or RS232 and/or Ethernet connector
- All analysis stored in Excel® compatible format
- Automatic calibration
- Ambient TemperatureMax 32 °C,
- Power :- 220V ± 15% / 50 to 60 Hz
Since its founding in 1938 by scientist, inventor and educator Dr. Michael R. Cannon, CANNON® Instrument Company has earned
international acclaim for the quality of its viscosityrelated products and services. We are proud of our unique alliance with NIST
(National Institute of Standards and Technology). As a NIST delegate for provision of U.S. national measurement standards in the
field of viscosity measurement, CANNON can offer our customers unique assurances of the quality of our products.
We also provide testing and certification for customer samples, and we have the capability to produce custom blend viscosity/density
standards to your specification. Every product that CANNON offers has been carefully crafted to meet or exceed specifications
required by international standards organizations including ASTM, SAE, ISO, and AASHTO. Our major equipment items are CE Mark
compliant. All CANNON Certified Viscosity Reference Standards are traceable to NIST.
PRODUCT :
1. AUTOMATED VISCOMETERS
Automated Viscometers for ASTM D445
Automated Viscometers for High Throughput Used Oil Analysis
Automated Viscometers for Polymer and Biopolymer Testing
Automated Viscometers for Pulp and Paper
2. MANUAL GLASS VISCOMETERS
3. CERTIFIED REFERENCE MATERIALS
Flash Point Reference Materials
Viscosity Standard
4. CONSTANT TEMPERATURE BATH
5. Etc.
VISCOMETER TUBE
Viscometers by Name
Asphalt Institute Vacuum BS/U Miniature Tube Cannon-Manning Semi-Micro Cannon-Ubbelohde Semi-Micro
Cannon-Manning Semi-Micro
BS/IP/MSL BS/U-Tube Modified Koppers Vacuum
Extra Low Charge
BS/IP/RF U-Tube Cannon-Fenske Routine Cannon-Manning Vacuum Ubbelohde
BS/IP/SL Cannon-Fenske Opaque Cannon-Ubbelohde Zeitfuchs Cross-Arm
Cannon Four-Bulb Shear
BS/IP/SL(S) Cannon-Ubbelohde Dilution Zeitfuchs Transparent
Dilution
VISCOSITY STANDARD
The Table below provides kinematic viscosity values for the General Purpose Viscosity Standards from CANNON Instrument
Company. CANNON certified standards are useful for calibration and verification procedures for all types of viscometers,
including glass capillary viscometers, rotational viscometers, falling ball viscometers, cup viscometers, and others. Calibration
or verification with a certified viscosity standard helps to ensure the reliability of measurements made with any viscometer.
AUTOMATED KINEMATIC VISCOMETER
Model : CAV 2000 Series
Designed for completely unattended operation, each CAV viscometer provides fully
automatic kinematic viscosity testing within parameters specified by ASTM D 445. The
CAV 2000 Series instruments measure flow rates within ±0.001 second by electronically
timing the liquid meniscus as it moves between thermistor sensors. Bath temperature is
controlled to an accuracy better than ±0.01°C at any selected temperature between
20°C and 100°C, and an accuracy better than ±0.03°C between and 100°C and 150°C
(high-temperature option required above 100°C), exceeding the precision requirements
of ASTM D 445. Thermal sensing technology ensures that dark or opaque liquids can be
measured with the same precision as transparent liquids.
Each CAV Bath Unit contains two viscometer tubes, each with a 100 fold kinematic
viscosity range (e.g., 1 to 100 cSt, 6 to 600 cSt, etc.). Fast-run tubes (10-fold range)
are also available for time-critical and/or high-throughput applications, A kinematic
viscosity range of 0.5 to 5000 cSt can be obtained within a single Bath Unit by selecting
two viscometers with complementary viscosity ranges. (see table for available tube
sizes).
SPECIFICATION :
Bath Unit Dimensions: 305 x 727 x 1245 mm, 12 x 35 x 49" (W x D x H)
Viscosity Range: 0.5 to 5000 cSt depending on viscometer tubes
Bath Temperature: Variable from 20°C to 100°C with an accuracy better than
0.01°C. High temperature bath option (up to 150°C, ± 0.03°C)
Drop Time Resolution: 0.01 seconds (timing accuracy to ±0.001 second)
Operating Conditions: 10%-90% RH non-condensing. Installation category II;
Pollution degree 2
Computer: Contact CANNON Instrument Company for current specifications and
an installation guide detailing space, equipment and utility requirements.
SPECIFICATION :
Operating Conditions: 15-30°C, 10%-90% RH non-condensing, Installation
Category II Pollution degree 2
Sample Volume : 40-50 mL required
CCS-2100LT
Working Temperature Range: –20°C to +40°C
Display: LED, actual/setpoint values
Temperature Stability: ±0.5°C
Display Resolution: 0.1°C
AUTO KINEMATIC VISCOMETER CAV 4.2
SPECIFICATIONS :
The CANNON® CAV® 4.2 is an automated, Automated sample capacity : 28 positions
high throughput, dual-bath kinematic Maximum throughput 24 tests per hour
viscometer for ASTM D445. The CAV® 4.2 Viscosity Range 0.5 mm2/s to 10,000 mm2/s
combines CANNON® quality and reliability Temperature Range : 20 °C to 100 °C ± 0.01 °C
with modern design and unique features to Timing resolution 0.01 seconds
enhance lab productivity, reduce costs, and Minimum Sample : 8mL sample/15mL solvent per test
improve data quality Dimensions (W x D x H) 36 cm x 66 cm x 72 cm
CHNS-O Elemental Analyser. EA3000 Series are compact, fully automatic instruments
for the most exacting determination of CHNS and O.
The Series is based on TurboFlash™ Combustion Technology, a patented principle to
inject a selected pressurized oxygen volume independently from carrier gas flow. The
innovation represents a quantum leap in the state of the art of well known Dynamic Flash
Combustion Principle.
EuroVector deliver instruments tested against "3Q" Qualifications. EuroVector provide
instrument configuration as well as analytical protocol including layout, instrument
parameters and a number of other suggestions to achieve accurate results in a variety of
applications such as :
EA3000
Callidus SW. Callidus® is a mature Software dedicated to the EuroVector Series of Elemental Analysers. It represents a major step
ahead for completeness and ease of use, providing the most elegant solutions on all functionalities. The SW provides full automatic
instrument control from parameters downloading to results printout in one of the user-configured report formats. It also provides
data reprocessing, preventive maintenance prompting, Leak Test and full Diagnostic.
How EuroEA works. In line with dynamic Flash Combustion Principle, a continuous flow of Helium is assured in the analytical
circuit. Helium gas is split into carrier gas and TCD reference arm flow. Sample is dropped from the AutoSampler into the
reactor, together with synchronised injection of pressurised Oxygen provided by TurboFlash® optimal combustion: gases such
as NXOX, CO2, H2O, SO2/SO3 are the results of the combustion stage. Reduction step allows for elimination of the Oxygen
excess converting the gas mixture into N2, CO2, H2O, SO2. The gases are time separated by GC column in less than 5 minutes
with peaks detected by TCD. The entire operation is driven by Callidus Software downloading instrument parameters, setting
Oxygen volume as per optimal TurboFlash combustion. Well shaped, baseline separated peaks are then integrated and results
printed out in one of the report formats selected by the user. All AutoRuns are automatically archived.
Since 2005 Bourevestnik, Inc. has been an affiliate branch of ALROSA Co., Ltd. Bourevestnik is 50 years old in May of
2009. Its products have become widely popular throughout these years due to comprehensive possibilities, reliability
and high quality of the equipment manufactured and due to its well-known users - leading research institutes and
largest industrial enterprises of Russia, CIS and non-CIS countries – from Ukraine and Belorussia to Switzerland and
the USA. Our staff includes highly proficient engineers, with doctors and candidates of sciences being among them.
Young employees work next to the most experienced ones.Bourevestnik, Inc. is the first enterprise in Saint Petersburg
to obtain all the three international and Russian certificates of management quality system (ISO 9001:2000),
environmental management system (ISO 14001:2004) and occupational safety and health management system (OHSAS
18001:1999).
SPECIFICATIONS :
● Range of determined elements from 9F to 92U
● Range of determination with sample preconcentration depending on
chemical element 1.5*10-5 %
● Limit of the middle group elements detection in liquids, mg/dm3 n*10-5
● Average time for 1 (one) sample analysis, 100 sec
● Maximum voltage of the X-ray tube, 50 Kv
● Cooling of the X-ray tube air
● Primary X-ray radiation filters Cd, Sr, Ni, Nb, Ti
● Power supply 220 V, 50 Hz
● Overall dimensions of the instrument (L х W х H), mm 700х410х400
BRA-135F
General purpose energy dispersive x-ray fluorescence spectrometer BRA-135F allows to simultaneously detect about two tens
of chemical elements during 300 sec maximum over a wide concentration range from hundreds of ppb. BRA-135F analyses
samples in solid, liquid and powder state as well as samples marked on the surface or deposited on the filters
X-RAY WAVELENGHT SULFUR ANALYZER
SPECIFICATIONS :
● Method of sulphur concentration determination Wavelength-Dispersive X-ray
fluorescence (WDX) with vacuum channel ● Sample Size: 32 to 78 ml
● Statistic limit of detection, max., 1.5 ppm
● Range of determined sulphur concentrations, from 5 to 50000 ppm
● Limits of basic relative error, ±0.3 %
● Power consumption, (from mains 220 VAC, 50 Hz) 250 VA
● Weight of the instrument, 45 kg
● Dimensions (L х W х H), mm 450х415х400
●According to EN ISO 20884 : 2004, IP 497/05, ASTM
D6334, D2622-2005
ASV-1
X-ray radiation of low duty X-ray tube converted by primary radiation filters excites the fluorescence radiation of atoms of the
sample under examination. Radiation flows (primary radiation scattered on the sample and secondary fluorescence radiation)
comes in analyzing crystal and fluorescence radiation of sulphur atoms (SKa) is reflected at a certain angle. The intensity of
sulphur atom`s fluorescence irradiation detected by proportional gas counter is proportional to the sulphur concentration in the
sample under examination..
SPECIFICATIONS :
● Range of determined elements from Сo (27) to U (92)
from Сo (27) to Ce (58) by К-series,
from Ta (73) to U (92) by L-series.
● Spectral resolution (half-width of a line U Lа1), eV, 40 max
● Concentration range, from 10-4 to 100 %
● Limits of basic relative error, 0,5 %
● Limit of U(92) detection in 100 sec, %, 1,5*10-4 max
● Number of samples loaded simultaneously, 30 pcs
● Power consumption, 4,6 kVA
● Weight 400 Kg
● Overall dimensions (L х W х H), mm 1300 х 1150 х 850
ARF-7
Specialized wavelength-dispersive XRF analyzer based on the Cochois scheme is designed for high-precision determination of
chemical elements U, Th, Mo, Au, W, Tl, As, Pb as well as other elements in ores, rocks and when developing the technogenic
fields. Principle of analyzer operation is based on the excitation of the fluorescent radiation of sample atoms being under
examination by radiation coming from an X-ray tube. Spectrum decomposition of the fluorescence radiation is performed
according to Cochois method. The fluorescence radiation focused by analyzing crystal and standard line are marked on Rowland
focal circle. Then, they are recorded by X-ray radiation detector in turn. The intensity of the fluorescent irradiation with a
particular wavelength is directly proportional to the chemical element concentration in the material under examination.
PoultenSelfe& Lee Ltd, (PSL) was established in 1850. Starting as just Poulten, Selfe& Lee were later acquired, with the company
“PoultenSelfe& Lee Ltd” being incorporated in 1931.Originally located in the East End of London, the company moved to purpose
made works in 1947, being the first factory to be built on the Russell Industrial estate in Wickford, Essex. The company became a
significant employer, with an extensive glassblowing shop as well as graduation and calibration laboratories.
In 1989, PSL was the first company to be accredited by the United Kingdom Accreditation Service (UKAS) for viscometer calibration
and testing.
In 2010, the management decided to merge the two in-house brand names of PSL and Rheotek. The purpose of this, was to send a
clear signal to the marketplace, that PoultenSelfe and Lee Ltd is the leading manufacturer of both manual and automated viscometers
for precision measurements.
PRODUCT :
1. AUTOMATED VISCOMETERS
2. GLASS VISCOMETERS
3. VISCOSITY STANDARD
4. TEMPERATURE BATH
5. THERMOMETER & HYDROMETER
Polymer, cellulose, Pulp &paper Viscometer Analyzer
Fully conform to :
ASTM D789, ISO 307, ASTM D4603, ISO 16285, ASTM D1243, ISO 16282, ASTM D2857, ISO 16281
SCAN 15:99, ISO 5351, ASTM D1795, TAPPI T230, IEC 60450, ASTM D4243
RPV-1 RPV-2
ASTM D789, ISO 307, ASTM D4603, ISO 16285, The RPV2 fully automates the dilute solution
ASTM D1243, ISO 16282, ASTM D2857, ISO 16281 viscosity measurement of a wide range of polymers,
Automated polymer viscometer configured with one pulp, cellulose and electrical papers in full
to four measuring positions. Each position has a compliance with ASTM, ISO and other test methods.
unique RPV filling station for sample introduction, Each analyzer is equipped with two automated
nlR meniscus detection for precise flow time measuring positions (suitable for ASTM or Din
measurements as well as an insitu solvent cleaning Ubbelohde or CannonFenske Routine viscometer
& drying system. Suitable for most types of tubes) situated in a liquid temperature controlled
polymers dissolved in acids, organic solvents and bath. Flow times are measured using a nIR detection
water, including PET, PA, PVC, PVA, PC, cellulose system suitable for a wide range of polymers. On
acetate and biopolymers. (For high temperature completion of measurement, samples are removed
polymer application e.g. PP & PE see RPV1 HT). and all wetted parts of the analyzer are cleaned with
a two or optional three stage solvent and air drying
programme.
VISCOMETER BATH
The TCB-7 bath can be used from 15 to 150°C, and is supplied with a built in cooling coil.
Operation at temperatures from 15ºC to 40ºC require an external source of chilling. This
is provided by a cool liquid, which is passed though the cooling coil. A low cost
recirculating chiller is available from PSL to provide the cooling required. The RHEOTEK
TLC- 1 Chiller is specially designed for operating with the TCB-7MkII bath.
Features:
● Calibration to 0.01ºC
● 7 Viscometer positions
● Small footprint
● Thermometer holder built in
● Cooling coil built in
● Stainless steel casing
● Splash proof keypad
● Range up to 150ºC
GLASS VISCOSITY
PSL-RHEOTEK offers a comprehensive range of precision calibrated glass capillary kinematicviscometers. These
are hand made by our experienced glass blowers from high grade borosilicate glass tubing. PSL viscometers are
used by laboratories throughout the world and enjoy a high reputation for quality workmanship and accuracy of
calibration. Calibration is performed on-site by our UKAS accredited ISO 17025 calibration laboratory.
Ayalytical Instruments introduces the Copper Digital Detection Imaging (CuDDI) test instrument, an
exclusive new standard of copper quality analysis for the petroleum industry, under its VISAYA product
line. Using a high resolution camera with optical intelligence, CuDDI identifies exact levels of corrosivity
present from petroleum through a 4 step automated vision algorithm and classification process. CuDDI is
higher precision, patent pending design eliminates guesswork and operator bias.
SPECIFICATIONS :
● Applicable Test Methods : ASTM D130, D1838
● The National Association of Corrosion Engineers (NACE) Compliance
● Corrosion Detection Range : 1a, to 4C
● Display Units : Color, ASTM Rating and Strip Size
● Detection Method : Digital Video Detection using CMOS Detector
● Precision : +/- 0.25% of Raw Reading
● Calibration : Vision Calibration with Standard, Measuring Time < 30 seconds
● Display : Optical Design Patent Pending Optical Arrangement; Light Source LED,
7,000K; 10.1” Projective Capacitance Touch (Multi Touch)
● Interface : Ethernet x2, USB 3.0 x1, USB 2.0 x4, HDMI, VGA, USB Printer, USB
Mouse and Keyboard;
● Memory / Storage : 32 GB SSD Storage
● Temperature Range : 10° to 35°C
●› Humidity : Up to 85% Non Condensing
● Power : Auto-switching 90 ~ 264VAC, 47 ~ 63Hz, 280 Watt Power Supply
● Space Requirements : 80 mm (3”) on Sides and Back
● Dimension : 350x300x270mm (14x12x11”)
● Weight : Weight 10 Kg.
Autocontrol Technologies was established in 1994 by its managing director, Roberto Scatizzi, in order to offer fresh solutions in the
on-line instrumentation, process measurements and control automation fields, assisting the customer from design to installation with
complete turn-key services.
The company’s core business is engineering, construction and installation of high technology process instruments for
the oil,
petrochemical, chemical and power industries.
The company is ISO 9001:2008 certified and ATEX notified for applications in hazardous areas.
AUTOMATIC SAMPLING
The company is an international leader in designing and manufacturing automatic sampling systems for crude oil and refined products.
Automatic Sampling is an increasingly worthy activity when oil custody transfer takes place.
The rising costs of raw materials, processing and disposal of pollutants have made a representative sample strategic because it
represents the entire batch of oil in transit.
Autocontrol Technologies has supplied its customers with automatic sampling units throughout the world in oil terminals, production
wells, off-shore platforms, tankers, refineries and metering skids. The company is also a permanent member of the main international
organisations (ISO, API) that regulate this strategic matter
THE OIL SAMPLING MARKET
Targets
• Composition Terminals
• Water Content
• Contaminant Content
• Fiscal Report
• Commercial Claims
Metering
• Insurance Claims Oil Fields
Skids
Typical Problems
• Instable Process
• Foam
• Metal Particles
• Process Interruptions
False Alarms
•
Custody
• Mission Critical Refineries
Transfer
Off Shore
SPECIFICATIONS :
1. Viscosity by Falling Sphere
2. Viscotool or Visgage, viscosity comparison of lube oils
3. Watercontent of fuels and lube oils
4. Nature of water (salt or fresh)
5. Density
6. TAN either TBN (or both)
7. Compatibility/Stability (ASTM modified method D4740-95)
8. Pourpoint
This test kit is specially developed to check the TBN value (alkalinity) of the engine’s
lubricating oil. The test
is performed by means of a pressure testvessel. With the basic kit approx. 50 tests
can be done.
The kit consists of:
- sturdy case
- reactionvessel with manometer and injectionvalve
- TBN test solution
- waterfree diluent
- magnetic stirrer
- 5 and 10 ml syringes
This test kit enables you to determine the percentage of water in your lube oil/fuel oil.
The test is performed by means of the ”Calcium Hydride Pressure Testvessel Method”.
The value obtained can be used as a check on the lube oil separator, any water
leakages and operation contamination. With the basic kit approx. 50 tests can be
done.
The kit consists of:
- sturdy case
- reactionvessel with manometer and injectionvalve
- water test solution
- waterfree diluent
- magnetic stirrer
- 1 and 5 ml syringes
SAMPLING EQUIPMENT
PRODUCT :
1. VISCOSITY STANDARDS
2. BIODIESEL STANDARDS
3. FLASH POINT STANDARDS
4. PARTICLE SIZE STANDARDS
5. SULFUR IN OIL STANDARDS
6. CHLORINE IN OIL STANDARDS
7. FTIR OPERATIONAL TEST STANDARDS
8. TAN & TBN STANDARDS
9. METAL IN OIL STANDARDS
10. ELEMENT OIL STANDARDS
VISCOSITY STANDARDS
CONOSTAN® certified mineral oil viscosity standards were developed for the calibration and
verification of all type of viscometers, including glass capillary viscometers, rotational
viscometers, cup and falling ball viscometers. All standards are traceable to National Standards
and according to ASTM & IP methods. Each standard carries a stability guarantee of up to 2 years.
The determination of kinematic and dynamic viscosity values were made in accordance with ASTM
D445/446 and ISO 3104/3105 and are traceable to NIST (National Institute of Standards and
Technology).
BIODIESEL STANDARDS
SCP SCIENCE offers a new line of biodiesel standards for the analysis of metals and
sulfur in biodiesel fuel. Manufactured in accordance to ASTM methods D7039, D6751,
D5453 and EN14214 for ICP and XRF analysis. Complete with a Certificate of Analysis.
SULFUR IN ISOOCTANE - This product category features very low, low and middle
concentration lines of Sulfur in Isooctane standards that were developed in accordance with
ASTM methods D5453, D4294, D6334, D3120, D3246, D3961, D4045, D6212, D6313 and
D6428 for the analysis of sulfur in gasoline or other petroleum products. Stocked concentrations
are shows in the table below
SULFUR IN RESIDUAL OIL - The product line features stocked standards from 2,500 µg/g to
50,000 µg/g (see table below). All other concentrations are available as custom standards and may
go as low as 1 µg/g. A Certificate of Analysis reporting concentrations and density is included with
each standard.
SULFUR IN MINERAL OIL - The product line features stocked standards from 0 ug/g
to 45,000 ug/g (see table below). All other concentrations are available as custom
standards and may go as low as 1 ug/g. The standards are specially engineered to have
an elevated flash point making it suitable for shipping as a non-hazardous product. A
Certificate of Analysis reporting concentration and density is included with each
standard.
SULFUR IN DIESEL FUEL - The product line features stocked standards from 5 ug/g S to
40,000 ug/g S (see table below). All other concentrations are available as custom
standards and may go as low as 1 ug/g. The standards are specially engineered to have
an elevated flash point making it suitable for shipping as a non-hazardous product. A
Certificate of Analysis reporting concentration and density is included with each standard.
SULFUR IN CRUDE OIL - We have 10 standards from 500 to 50000 ppm. Sulfur in Crude Oil
in accordance with Method ASTM D2622 and D4294. Complete with a Certificate of Analysis.
CONOSTAN®'s industry leading chlorine line is designed for calibration of XRF, ICP and other
analytical techniques. Stocked concentrations in 4oz (100g) product sizes are shown in the
table to the right. Other concentrations are available as custom blends.
TAN standards, the pH change in the titration curve is now greater than even the
highest concentrations of competitive standards. Because the inflection point is more
prominent, CONOSTAN TAN standards offer uncertainties less than 1%
TBN standard is formulated to provide a strong levering influence on the titration curve
creating dramatic and easy to determine inflection points. Concentration uncertainties
for TBN are leass than 1%.