Professional Documents
Culture Documents
Va1 FLS 00ead03 e M2 DWD 0608 - 0
Va1 FLS 00ead03 e M2 DWD 0608 - 0
C 13.10.11 CS-M2-E-00144
B 05.09.11 CS-M2-E-00141
VIETNAM MACHINERY
INSTALLATIONCORPPORATION (LILAMA)
FICHTNER GmbH & Co.KG
PROJECT TITLE
DRAWING TITLE
Circuit diagram Stacker 00EAD03/04
Coal Handling system
MVT_001
A A
C Customer LILAMA C
E E
2
Date 13.10.2011 2.2040 COVER
Title page/cover sheet Stacker
Ed. by cw-de +
Appr. VUNG ANG Page 1
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
FUNCTION LOCATION B
+X EXTERNAL
+A008 POWER TERMINAL BOX MAIN FEEDING
+A009 TERMINAL BOX BOOM LUFFING
+A010 JUNCTION BOX TRAVEL DRIVE
D
+GY HYDRAULICS VALVES D
E E
==TERMINAL TERMINALS
==CBL CABINET LAYOUT
==SUMMPARTLIST SUMMARIZED PARTS LIST
==PARTLIST PARTLIST
G G
1 3
Date 13.10.2011 2.2040 COVER
FUNCTION AND LOCATION CODE Stacker
Ed. by cw-de +
Appr. VUNG ANG Page 2
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
FUNCTIONS
A A
B B
AP020 RAIL CALMP 2 CG132 RAIL CLAMP 2 LOW FLUID LEVEL SWITCH STOPS PUMP MOTOR
AE004 CABLE DRUM CG133 RAIL CLAMP 1 STORM BRAKE RELEASED LIMIT SWITCH
GQ001 EXTERNAL POWER SPARE CG134 RAIL CLAMP 2 STORM BRAKE RELEASED LIMIT SWITCH
GU002 AUXILIARY TRANSFORMER CG140 CABLE REEL
GS002 AUXILIARY FEEDER CG150 STORM LOCK BOLT 1 OPEN INI 1
GR001 24 V DC CONTROL VOLTAGE CG151 STORM LOCK BOLT 1 OPEN INI 2
GP001 EXTERNAL LIGHTING CG152 STORM LOCK BOLT 2 OPEN INI 1
D
AH001 AIRCON E-HOUSE CG153 STORM LOCK BOLT 2 OPEN INI 2 D
CH102 E-STOP 1 PLACED ON BOOM CONVEYOR CT112 PTC TRAVEL DRIVE MOTOR 2 OK
CH111 LOCAL CONTROL BOX TRAVEL DRIVE CT113 PTC TRAVEL DRIVE MOTOR 3 OK
CH112 E-STOP 2 LADDER TO HYDRAULICS CT114 PTC TRAVEL DRIVE MOTOR 4 OK
CH113 E-STOP 3 STAIRS TO E-HOUSE CT115 PTC BOOM LUFFING MOTOR OK
CH114 E-STOP 4 LADDER TO TRIPPERCAR CT131 RAIL CLAMP 1 LOW OIL
CH115 E-STOP 5 MIDWAY TRIPPER CAR CT132 RAIL CLAMP 2 LOW OIL
CH121 LOCAL CONTROL BOX BOOM LUFFING CL101 TRIPPER CAR CHUTE BLOCKED MONITORING
F
CH122 E-STOP 6 PLACED ON HYDRAULICS CL121 LEVEL CONTROLLER BOOM LUFFING HYDRAULICS POS 9 F
CG104 BOOM CONVEYOR BRAKE OPEN SWITCH CL131 RAIL CLAMP 1 LOW OIL
CG001 TRAVEL DRIVE POSTION ENCODER CL132 RAIL CLAMP 2 LOW OIL
CG101 BOOM CONVEYOR MISALIGNMENT SWITCHES ALARM CP001 PRESSURE SWITCH BOOM LUFFING HYDRAULICS POS 2.105
CG102 BOOM CONVEYOR MISALIGNMENT SWITCHES WARNING CP002 PRESSURE SWITCH BOOM LUFFING HYDRAULICS POS 2.109
CG105 TRIPPER CAR MISALIGNMENT SWITCHES ALARM CP003 PRESSURE SWITCH BOOM LUFFING HYDRAULICS POS 3.18
CG106 TRIPPER CAR MISALIGNMENT SWITCHES WARNING CP121 BOOM LUFFING HYDRAULICS POS 69 PRESSURE SWITCH
G CG111 TRAVEL DRIVE MICRO SWITCHS BRAKES G
G F0 F1 F2 F3 FN N0 NNN
-X1 690/400 V AC
C -X2 230 V AC G: 0 - Common to Unit 1 and Unit 2 C
PE GENERAL GREEN/YELLOW
NNN 001-999
MAIN CIRCUIT 400V AC L1 RED, L2 YELLOW, L3 BLUE, N BLACK,
PE GREEN YELLOW
CONTOL CIRCUIT 110V or 230V AC L1 RED, N BLACK, PE GREEN YELLOW
G
CONTROL CIRCUIT 24V DC L+ GREY, L- BLUE G
3 ==CONTENT/5
Date 13.10.2011 2.2040 COVER
TERMINAL AND CABLE Stacker
Ed. by cw-de DESIGNATION +
Appr. VUNG ANG Page 4
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
==COVER/4 6
Date 13.10.2011 2.2040 CONTENT
TABLE OF CONTENT Stacker
Ed. by cw-de +
Appr. VUNG ANG Page 5
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
5 7
Date 13.10.2011 2.2040 CONTENT
TABLE OF CONTENT Stacker
Ed. by cw-de +
Appr. VUNG ANG Page 6
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
&VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/95 DIGITAL INPUT BYTE 20 DIGITAL INPUT BYTE 19 CHECKBACK SIGNAL LCB'S DI 13.10.2011 cw-de
&VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/96 DIGITAL INPUT BYTE 21 DIGITAL INPUT BYTE 19 CHECKBACK SIGNAL LCB'S DI 13.10.2011 cw-de
&VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/97 DIGITAL INPUT BYTE 22 SPARE 13.10.2011 cw-de
&VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/98 DIGITAL INPUT BYTE 23 SPARE POWER BRAKE DOWN 13.10.2011 cw-de
&VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/99 ANALOG INPUTS IW 256-263 13.10.2011 cw-de
G G
6 8
Date 13.10.2011 2.2040 CONTENT
TABLE OF CONTENT Stacker
Ed. by cw-de +
Appr. VUNG ANG Page 7
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
7 9
Date 13.10.2011 2.2040 CONTENT
TABLE OF CONTENT Stacker
Ed. by cw-de +
Appr. VUNG ANG Page 8
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
8 10
Date 13.10.2011 2.2040 CONTENT
TABLE OF CONTENT Stacker
Ed. by cw-de +
Appr. VUNG ANG Page 9
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
9 11
Date 13.10.2011 2.2040 CONTENT
TABLE OF CONTENT Stacker
Ed. by cw-de +
Appr. VUNG ANG Page 10
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
10 12
Date 13.10.2011 2.2040 CONTENT
TABLE OF CONTENT Stacker
Ed. by cw-de +
Appr. VUNG ANG Page 11
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
11 13
Date 13.10.2011 2.2040 CONTENT
TABLE OF CONTENT Stacker
Ed. by cw-de +
Appr. VUNG ANG Page 12
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
G G
12 ==SL/14
Date 13.10.2011 2.2040 CONTENT
TABLE OF CONTENT Stacker
Ed. by cw-de +
Appr. VUNG ANG Page 13
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
MOTORLIST_001
Karl-Koch-Strasse 1
66787 Wadgassen/Germany
B B
C C
E E
F F
G G
==CONTENT/13 15
Date 13.10.2011 2.2040 SL
SINGLE LINE DIAGRAM Stacker
Ed. by cw-de +
Appr. VUNG ANG Page 14
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
690V / 50 Hz / 3~/TN-S BUSBAR SYSTEM 400V / 50 Hz / 3~/TN-S BUSBAR SYSTEM 400V / 50 Hz / 3~/TN-S
A A
1 1 1
-Q00 -Q01 -Q01 -Q01 -Q01 -Q01 -Q01 -Q01 -Q01 -Q01
-F01 3 -F02 3
I> I> I> I> I> I> I> I> I> I>
2 2 2
3+PE
2+PE
-Q02 3 -Q01 -Q02
-Q02
-T01
50 kW
3
690/400V -T01 -G01 -Q02 -Q02 -Q02 -Q02
FEEDER 3
TRANSFORMER 2
2
110V / 1~ / 50Hz
3
B 3 B
-T01
24V / DC
3
3
COMBINED
CABLE REEL -X1
-X1 -X6 -X1 -X6 -X1 -X1 -X1 -X1
Power & Control
2 2 2 2
EXTERNAL
FEEDING BOOM MAIN 110 V AC 24 V DC BOOM TRAVEL TRAVEL TRAVEL TRAVEL TRAVEL TRAVEL TRAVEL TRAVEL BOOM LUFFING RAIL RAIL CABLE DRUM POWER
POINT CONVEYOR TRANSFORMER CONTROL AUXILIARY CONVEYOR DRIVE 1 DRIVE 2 DRIVE 3 DRIVE 4 DRIVE 1 DRIVE 2 DRIVE 3 DRIVE 4 HYDRAULICS CLAMP 1 CLAMP 2 SPARE
VOLTAGE ELTRO BRAKE BRAKE BRAKE BRAKE BRAKE
-Q01
00 I>
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
EAD03 EAC03 EAD03 EAD03 EAD03 EAC03 EAD03 EAD03 EAD03 EAD03 EAD03 EAD03 EAD03 EAD03 EAD03 EAD03 EAD03 EAD03 EAD03
GS001 AF001 GU001 GY001 GR002 AF001 AE001 AE001 AE001 AE001 AE001 AE001 AE001 AE001 AE002 AP010 AP020 AE004 GQ001
3+PE
-T01
15 kW
690/400V
FEEDER 3
TRANSFORMER
D D
-F01 3
-Q01 4
30mA
E E
-Q01
-F01 2 -F01 2
I>
A1
3
-Q01
3 A2
-G01
2
24V / DC
F F
-X1 -X1
-H01
8 kW
-E01
6,4 kW
*
00 00 00 00 00
EAD03 EAD03 EAD03 EAD03 EAD03
GU002 GS002 GR001 GP001 AH001
14 ==00EAD03=GS001+F01/16
Date 13.10.2011 2.2040 SL
SINGLE LINE DIAGRAM Stacker
Ed. by cw-de MAIN +
Appr. VUNG ANG Page 15
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
1 3 5 12 14 22 24 32 34 1 3 5
B +F01-6-Q000 -Q001 B
62,5-125 A 11 21 31 1-1,6 A
I> I> I> I> I> I>
=EH001+F04/75.1
2 4 6 2 4 6
+F01-6-T003 L3
200A/1A S2
F Hz
S2
PE U P
I F PF E
+F01-6-X1 1 2 3 PE
AUX.
SUPPLY
Profibus 12-48 VDC
-1000 Address DP AUX1 AUX2
H07 RN-F 20
10 m
4x70 BN BK GY GNYE
E E
+W000
L1 L2 L3 PE
R R R R
-X1 S S S S
=AE001/27.4 / PB_DP
F F
=GR001+F04/51.4 / F017_24V
L2 / +A008/17.0
=GR001+F04/51.4 / F017_0V
+A008
-X1 1 2 3 PE
RXG-8(N)SHTöu-J 0.6/1KV
L1 L2 L3 PEN 3x70 + 2 x 35/2 mm² + 12G62,5/125µ
199 m
G G
MAIN FEEDING
SUPPLY
00EAD03AF001
==SL=+/15 +A008/17
Date 13.10.2011 2.2040 00EAD03 GS001
MAIN FEEDING Stacker
Ed. by cw-de + F01
Appr. VUNG ANG Page 16
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
+F01/16.2 / L1
+F01/16.2 / L2
A A
1 3 5
-Q001
1-1,6 A
(1,22)
I> I> I>
2 4 6
B B
-X4 3 4
-PE
1 2
-T001 -U002
-XT001
0,8kVA
690V 3 4
110V
C C
1
-F001
C 1A 2
D D
2 1
E E
-X4 1 2
F F
G G
+F01/16 =GU001+F01/18
Date 13.10.2011 2.2040 00EAD03 GS001
TRANSMISSION FIBRE OPTIC Stacker
Ed. by cw-de + A008
Appr. VUNG ANG Page 17
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
==00EAC03=AF001/136.8 / L1L690
TN-S 690V
L1L400 / =GR002+F02/19.1
==00EAC03=AF001/136.8 / L2L690 L2L400 / =GR002+F02/19.1
A ==00EAC03=AF001/136.8 / L3L690 L3L400 / =GR002+F02/19.1 A
N_400 / =GR002+F02/19.1
1 3 5 12 14 22 24 32 34
B +F01-4-Q001 B
40-80 A 11 21 31
I> I> I>
=EH001+F04/77.1
2 4 6 PE
+F01-4-X1 1 2 3 PE
-1001
H07 RN-F
15 m
4x25 BN BK GY GNYE
1 3 5 13
C +X-T001 1U 1V 1W +F01-3-Q002 C
50kVA PE
690/400V 2 4 6 14
=EH001+F04/78.6
IP31
Zzna0
D D
2W 2U 2V 2N
-1002
H07 RN-F
15 m
5x25 BN BK GY BL
E E
+F01-4-X1 4 5 6 7 PE
-PE
F F
G G
=GS001+A008/17 =GR002+F02/19
Date 13.10.2011 2.2040 00EAD03 GU001
FEEDER TRANSFORMER Stacker
Ed. by cw-de + F01
Appr. VUNG ANG Page 18
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
=GU001+F01/18.8 / L1L400
TN-S 400V
L1L400 / ==00EAC03=AF001/138.1
=GU001+F01/18.8 / L2L400 L2L400 / ==00EAC03=AF001/138.1
A =GU001+F01/18.8 / L3L400 L3L400 / ==00EAC03=AF001/138.1 A
B B
1 3 5 13 21
+F02-7-Q001
6,3-10A 14 22
(6,3)
=EH001+F04/83.7
I> I> I>
2 4 6
-PE
C C
L1 L2 L3
+F02-7-G001 3
24V DC
10A +F02-7-XT001
+ -
+ -
D D
E E
20.0 / AUXL+
20.0 / AUXL-
F F
G G
=GU001+F01/18 20
Date 13.10.2011 2.2040 00EAD03 GR002
24 V DC AUXILARY VOLTAGE Stacker
Ed. by cw-de + F02
Appr. VUNG ANG Page 19
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
19.1
A AUXL+ A
1 13 21 1 13 21 1 13 21 1 13 21 1 13 21
B +F02-7-F001 +F02-7-F002 +F02-7-F003 +F02-7-F004 +F02-7-F005 B
B 6A 2 14 22 B 6A 2 14 22 B 6A 2 14 22 B 6A 2 14 22 B 6A 2 14 22
=EH001+F04/86.4
=EH001+F04/86.5
=EH001+F04/86.6
=EH001+F04/86.7
=EH001+F04/86.7
C C
19.2
AUXL-
D +F02-7-X4 1 2 3 4 5 6 7 8 9 10 D
=CH102 33 =CH102 43
+F03 +F03
-A002 34 -A002 44
=CH102+/106.8 =CH102+/106.9
E E
=AE002+F04/31.1 / F001_24VAUX
=AE002+F04/31.1 / F001_0VAUX
=AE002+F04/34.0 / F002_24VAUX
=AE002+F04/34.0 / F002_0VAUX
=AP010+F04/39.1 / F003_24VAUX
=AP010+F04/39.1 / F003_0VAUX
F F
==00EAC03=AF001+F02/139.8 / L1L400
TN-S 400V
L1L400 / 25.1
==00EAC03=AF001+F02/139.8 / L2L400 L2L400 / 25.1
==00EAC03=AF001+F02/139.8
A / L3L400 L3L400 / 25.1 A
1 3 5 12 14 22 24 32 34 1 3 5 13 21
+F01-2-Q001 +F01-2-Q002
40-80 A 11 21 31 0,63-1,0 A 14 22
(0,84)
=EH001+F04/81.6
I> I> I> I> I> I>
=EH001+F04/81.5
B
2 4 6 2 4 6 B
1 2
+F01-2-T001 -PE
0,16kVA
400V 3 4
110V
C +F01-2-XT001 C
1 3 5 1 13 21
+F01-2-Q003 +F01-2-F001
/21.5 2 4 6 C 1A 2 14 22
=EH001+F04/81.7
+F01-2-X9 1
D D
=CH102 1
+F03-X3
43
+F03
-A001 44
/26.1
=CH102 2
+F03-X3
-PE
E E
+F01-2-X9 2
110V_TRD_L / 22.7
+F01-2-X1 1 2 3 PE
-1003
H07 RN-F
5m
4x25 BN BK GY GNYE
12 14
+F01-2-K003
F =EH001+F04/101.4 11 F
1 2 /21.1
+F03-X1 1 2 3 PE 3 4 /21.1
5 6 /21.1
13 14 =EH001+F04/81.7
21 22
A1 31 32 /26.3
+F01-2-Q003 43 44
37kW A2 13X 14X
22.0 / TRD-L1
22.1 / TRD-L2
22.1 / TRD-L3
22.1 / TRD-PE
21X 22X
+F01-2-X9 5
G 110V_TRD_N / 22.8 G
TRAVEL DRIVE
=GR002+F02/20 MAIN CONTACTOR 22
Date 13.10.2011 2.2040 00EAD03 AE001
TRAVEL DRIVE MAIN CIRCUIT Stacker
Ed. by cw-de + F01
Appr. VUNG ANG Page 21
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
A A
=GR001+F04/49.5 / F0021_0V
=GR001+F04/49.4 / F0021_24V
B
=EH001+F04/64.3 =GS001/16.5 B
TRD-PE / 21.1
TRD-L1 / 21.1
TRD-L2 / 21.1
TRD-L3 / 21.1
PB_DP PB_DP
PB
+24V GND DI1 DI2 DI3 DI4 DI5 DI6 +24VD +24VD DGND1 DGND2 DIIL +24V GND
+F03-T002
=EH001+F04/63.3 U1 V1 W1 PE X23.1 X23.2 X41.1 X41.2 X41.3 X41.4 X22.1 X22.2 X22.3 X22.4 X22.5 X22.6 X22.7 X22.8 X22.9 X22.10 X22.11 X23.1 X23.2
C C
POWER Auxiliary power output Terminal for optional 6 digital inputs Internal supply for Start Auxiliary power output
24 VDC 250 mA Prevention of Unexpected Start digital inputs interlock 24 VDC 250 mA
input
Jumper J1
cable
Grounds of input groups
DI1...DI4 and DI5/DI6/DIIL
are separate (insulation
voltage 50 V).
J1
ACS800-01-0060-3 1xRO 1xRO 1xRO
Relay output Relay output Relay output
1xAI 2xAI 2xAO
Reference voltage Analogue inputs Analogue inputs Analogue outputs
Breake options
D DRIVE
+/- 10V 10mA +/- 0(2)...10V +/- 0(4)...20mA +/- 0(4)...20mA D
UDC+
U2 V2 W2 PE R- R+ UDC- X20.1 X20.2 X21.1 X21.2 X21.3 X21.4 X21.5 X21.6 X21.7 X21.8 X21.9 X21.10 X21.11 X21.12 X25.1 X25.2 X25.3 X26.1 X26.2 X26.3 X27.1 X27.2 X27.3
VREF- AGND VREF+ AGND AI1+ AI1- AI2+ AI2- AI3+ AI3- AO1+ AO1- AO2+ AO2- RO1 RO1 RO1 RO2 RO2 RO2 RO3 RO3 RO3
-PE
-1053
H07 RN-F
10 m 1 2 /25.1
3x2.5 BN BU
3 4 /25.1
5 6 /25.1
+F03-L001 x1 x3 x5 A1 13 14 =EH001+F04/82.1
du/dt 21 22
+F03-Q004
4kW A2 31 32 /26.2
43 44
x2 x4 x6
+X 13X 14X
R+ R-
21X 22X
F
-PE -R001 F
21.8 / 110V_TRD_N 110V_TRD_N / 23.0
T1
-1004 +F03-X1 4 5 6 PE 8Ω
H07 RN-F 4,5kW T2
20 m
4x25 BN BK GY GNYE
=EH001+F04/82.7
TRAVEL DRIVE
+A010-X1 1 2 3 PE BRAKES
23.0 / L1U2
23.0 / L2V2
23.0 / L3W2
23.0 / PE
G G
21 23
Date 13.10.2011 2.2040 00EAD03 AE001
TRAVEL DRIVE FREQUENCY Stacker
Ed. by cw-de CONVERTER + F01
Appr. VUNG ANG Page 22
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
22.0 / L1U2
TN-S 400V
L1U2 / 24.0
22.1 / L2V2 L2V2 / 24.0
A 22.1 / L3W2 L3W2 / 24.0 A
22.8 24.0
110V_TRD_L 110V_TRD_L
B B
1 3 5 13 21 1 3 5 13 21
+A010 +A010
-F002 14 22
-F003 14 22
C16 A 2 4 6 C16 A 2 4 6
=EH001+F04/82.2
=EH001+F04/82.3
C C
+F03-X5 1 2 3 4
-4002
/23.6
/24.1
/24.6
110V_TRD_N H05VV5-F -4002 110V_TRD_N
22.8 20 m 24.0
1 2 /23.1 3 4
9x1,5
E E
22.1 / PE PE / 24.0
+A010 1 2
+A010 4 5 6 PE
+A010 3 4
+A010 7 8 9 PE
-X5 -X1 -X5 -X1
-4003 -1005 -4004 -1006
H05VV5-F H07 RN-F H05VV5-F H07 RN-F
10 m 10 m 10 m 10 m
3x1,5 1 2 4x2.5 BN BK GY GNYE 3x1,5 1 2 4x2.5 BN BK GY GNYE
U1 V1 W1 U1 V1 W1
F M M F
+X-M001 3~ +X-M002 3~
/25.1 Θ
/25.3 Θ
/25.1 /25.3
7,5 kW 7,5 kW
15,4 A 15,4 A
rpm 1500 rpm 1500
22 24
Date 13.10.2011 2.2040 00EAD03 AE001
TRAVEL DRIVE MOTOR 1 AND 2 Stacker
Ed. by cw-de + F01
Appr. VUNG ANG Page 23
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
23.8 / L1U2
TN-S 400V
23.8 / L2V2
A 23.8 / L3W2 A
23.8
110V_TRD_L
B B
1 3 5 13 21 1 3 5 13 21
+A010 +A010
-F004 14 22
-F005 14 22
C16 A 2 4 6 C16 A 2 4 6
=EH001+F04/82.4
=EH001+F04/82.5
C C
+F03-X5 5 6 7 8
E E
23.8 / PE
+A010 5 6
+A010 10 11 12 PE
+A010 7 8
+A010 13 14 15 PE
-X5 -X1 -X5 -X1
-4005 -1007 -4006 -1008
H05VV5-F H07 RN-F H05VV5-F H07 RN-F
10 m 10 m 10 m 10 m
3x1,5 1 2 4x2.5 BN BK GY GNYE 3x1,5 1 2 4x2.5 BN BK GY GNYE
U1 V1 W1 U1 V1 W1
F M M F
+X-M003 3~ +X-M004 3~
/25.5 Θ
/25.7 Θ
/25.5 /25.7
7,5 kW 7,5 kW
15,4 A 15,4 A
rpm 1500 rpm 1500
23 25
Date 13.10.2011 2.2040 00EAD03 AE001
TRAVEL DRIVE MOTOR 3 AND 4 Stacker
Ed. by cw-de + F01
Appr. VUNG ANG Page 24
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
21.8 / L1L400
TN-S 400V
L1L400 / =AE002+F02/28.1
21.8 / L2L400 L2L400 / =AE002+F02/28.1
A 21.8 / L3L400 L3L400 / =AE002+F02/28.1 A
=EH001+F04/82.6
+F01-2-X1 4 5
B B
+F03-X1 7 8
1 3 5
+F03-Q004
/22.8 2 4 6
C C
+F03-X6 1 2 3 4 PE
-4007
H05VV5-F
20 m
5x1,5 1 2 3 4 GNYE
D D
+A010-X6 1 2 3 4 PE 5 6 7 8 PE 9 10 11 12 PE 13 14 15 16 PE
E E
+X-M001 PMG 500 +X PMG 500 +X PMG 500 +X PMG 500
/23.2 PE -M002 PE -M003 PE -M004 PE
/23.7 /24.2 /24.7
+ - + - + - + -
+X-M001 +X +X +X
/23.2 -M002 -M003 -M004
F FDW Size 20 F
/23.7 /24.2 /24.7
400AC/180VDC FDW Size 20 FDW Size 20 FDW Size 20
0,35A
IP66 400AC/180VDC 400AC/180VDC 400AC/180VDC
0,35A 0,35A 0,35A
IP66 IP66 IP66
G G
BRAKE BRAKE BRAKE BRAKE
TRAVEL TRAVEL TRAVEL TRAVEL
MOTOR 1 MOTOR 2 MOTOR 3 MOTOR 4
24 26
Date 13.10.2011 2.2040 00EAD03 AE001
TRAVEL DRIVE MOTOR 1 AND 2 Stacker
Ed. by cw-de BRAKES + F01
Appr. VUNG ANG Page 25
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
=GR001+F04/49.4
F0020_24V
A A
+F01-2-X3 3
-4013
/26.5
=EH001+F04/80.3
=EH001+F04/80.3
H05VV5-F
10 m
5x1,5 1
+LC01-X3 1
=CH102 43
B +F03 B
-A001 44
=CH102+/106.5
13 23
-S001
14 24
=EH001+F04/80.3
+F03
C -A001 A1 Y10 Y11 Y12 Y21 Y22 C
24V DC
+LC01-X3 2
13 23 31 43 53
SIEMENS
3TK2827-1AB21 14 24 32 44 54 -4013
/26.5
=EH001+F04/80.7
/21.6
H05VV5-F
5x1,5 2
=EH001 12 14
+F04
-K011 11
-PE =EH001+F04/102.2
+F01-2-X3 1
=EH001 12 14 31
+F04 +F01-2-Q003
E -K012 11 /21.5 32 E
=EH001+F04/102.3
RESET
31 +F01-2-X3 2
+F03
+F01-2-X3 5 6 7 8 9 10 11 12
-Q004 32
/22.8
-4015 -4016 -4017 -4018
=EH001+F04/80.4 =EH001+F04/80.5 =EH001+F04/80.5 =EH001+F04/80.6
=EH001+F04/80.4 =EH001+F04/80.5 =EH001+F04/80.5 =EH001+F04/80.6
H05VV5-F H05VV5-F H05VV5-F H05VV5-F
F 25 m 25 m 25 m 25 m F
5x1,5 1 2 5x1,5 1 2 5x1,5 1 2 5x1,5 1 2
=EH001+F04/80.4
=EH001+F04/80.5
=EH001+F04/80.6
=EH001+F04/80.7
=GR001+F04/49.5
F0020_0V
G G
=GR001+F04/49.5 / F003_24V
=GR001+F04/49.6 / F003_0V
A A
B B
C C
PE
=GS001/16.5 / PB_DP
+F04-X4 1 2 PE
D D
-4019
H05VV5-F
25 m
3x1,5 1 2 GNYE
=CG001
+X-G01 + - PE
=EH001+F04/63.7
E E
10...30 VDC Profibus_IN Profibus_OUT
BAUMER
Profibus Address
30
F ABSOLUTE ENCODER F
G
TRAVEL DRIVE G
POSTION
ENCODER
26 =AE002+F02/28
Date 13.10.2011 2.2040 00EAD03 AE001
TRAVEL DRIVE POSTION ENCODER Stacker
Ed. by cw-de + F01
Appr. VUNG ANG Page 27
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
=AE001+F01/25.8 / L1L400
TN-S 400V
L1L400 / 29.1
=AE001+F01/25.8 / L2L400 L2L400 / 29.1
A =AE001+F01/25.8 / L3L400 L3L400 / 29.1 A
=EH001+F04/83.1
I> I> I>
=EH001+F04/83.4 14
B
2 4 6 B
13 13
12 12
21
-Q003
=CH102+/107.5 22
11 11
C C
1 3 5
-Q003
/28.5 2 4 6
9 9
8 8
7 7
110VL1 / 29.3
D D
6 6
110VN1 / 29.3
5 5
4 4
13
-Q001
=CT115 12 14 -S1 -T1 =EH001+F04/83.1 14
-K001 =EH001+F04/83.5 3 3
E E
110-130VAC 11
-A1 -A2 -X1 -T2
1 1,
-Q003A1 / 29.1
2 2
A1 -Q003A2 / 29.2
-Q003
20kW A2
+X-M001 3~ 21 22 =CH102+/107.5
11kW Θ
400/690 V PE
21,5 A
G G
1500 rpm
IP55 BOOM
LUFFING
HYDRAULICS
=AE001+F01/27 29
Date 13.10.2011 2.2040 00EAD03 AE002
BOOM LUFFING HYDRAULICS MAIN Stacker
Ed. by cw-de CIRCUIT + F02
Appr. VUNG ANG Page 28
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
28.8 / L1L400
TN-S 400V
L1L400 / 30.1
28.8 / L2L400 L2L400 / 30.1
A 28.8 / L3L400 L3L400 / 30.1 A
1 3 5 13 21
+F02-7-Q002
0,63-1,0 A 14 22
(0,84)
=EH001+F04/83.2
I> I> I>
B
2 4 6 B
-PE
1 2
+F02-7-T002 +F02-7-XT001
0,16kVA
400V 3 4
110V
1 13 21
+F02-7-F001
C 1A 2 14 22
C C
=EH001+F04/83.3
110VL1 / 28.8
110VN1 / 28.8
D D
=CH102 3
+F03-X3
13
=CH102
+F03-A002 14
=CH102+/106.7
=CH102 4
+F03-X3
E E
12 14
+F04-K004
=EH001+F04/101.5 11
28.8 / -Q003A1
28.8 / -Q003A2
F F
G G
28 30
Date 13.10.2011 2.2040 00EAD03 AE002
BOOM LUFFING HYDRAULICS Stacker
Ed. by cw-de CONTROL CIRCUIT + F02
Appr. VUNG ANG Page 29
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
29.8 / L1L400
TN-S 400V
L1L400 / =AP010/37.1
29.8 / L2L400 L2L400 / =AP010/37.1
A 29.8 / L3L400 L3L400 / =AP010/37.1 A
B B
1 13 21
+F02-7-F002
B 6A 2 14 22
=EH001+F04/83.7
C C
D D
-PE
-X2 1 PE 2
E
-1010 E
H07 RN-F
20 m
3x1.5 BN GNYE BU
-E001
F F
G BOOM LUFFING G
HYDRAULICS
MOTOR COMPARTMENT
HEATING
29 +F04/31
Date 13.10.2011 2.2040 00EAD03 AE002
BOOM LUFFING HYDRAULICS Stacker
Ed. by cw-de MOTOR COMPARTMENT HEATING + F02
Appr. VUNG ANG Page 30
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
=GR002+F02/20.0 / F001_24VAUX
A =GR002+F02/20.1 / F001_0VAUX A
12 14
=EH001
-K013 11
=EH001/102.4
A1
-PE 14
-K001
B 12 11 =EH001/83.6
A2 B
+ - PE S1 S2 S3 S4 0V
-U1 status enabling
Proportional 1 1 8 13 14 15 16 4 7 3
valve 18...30V 5...30 VDC
18...30 VDC
amplifier channel calling
C C
PWD 00A-400
MAGN A 0... -10 VDC
MAGN B 0...+10 VDC
+ 5 U1+10V / =EH001/105.2
0V
D
- 6 U1-10V / =EH001/105.4 D
9 10 11 12
-PE
E
-X4 PE 1 2 3 4
E
-4021
H05VVC4V5-K
20 m
5x2.5 GNYE 1 2 3 4
+A009-X4 PE 1 2 3 4 PE
-4022 -4023
H05VVC4V5-K H05VVC4V5-K
10 m 10 m
3x1.5 GNYE 1 2 3x1.5 1 2 GNYE
F F
+GY-Y001A +GY-Y001B
Proportional valve Proportional valve
G G
MAGNET A MAGNET B
+F02/30 32
Date 13.10.2011 2.2040 00EAD03 AE002
BOOM LUFFING HYDRAULICS Stacker
Ed. by cw-de PROPORTIONAL VALVE AMPLIFIER + F04
Appr. VUNG ANG Page 31
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
A A
=CP001 =CP002 =CP003
+GY-B001 +GY-B002 +GY-B003
PRESSURE PRESSURE PRESSURE
SWITCH SWITCH SWITCH
B B
1 4 2 5 3 1 4 2 5 3 1 4 2 5 3
C C
+A009-X4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
GY+ / 33.0
GY- / 33.0
-4024
/33.0
D H05VVC4V5-K D
20 m
18x1.5 1 2 3 4 5 6 7 8 9 10 11
-X4 5 6 7 8 9 10 11 12 13 14 15
E =GR001/50.8 E
A1 A1 A1 A1 A1 A1
+F03 +F03 +F03 +F03 +F03 +F03
-KH002 A2
-KH003 A2
-KH004 A2
-KH005 A2
-KH006 A2
-KH007 A2
F
=GR001/50.9 33.0 F
F0132_0V F0132_0V
12
14
12
14
12
14
12
14
12
14
12
14
11
11
11
11
11
11
=EH001/85.5
=EH001/85.6
=EH001/85.1
=EH001/85.4
=EH001/85.3
=EH001/85.2
G G
A A
=CL121
+GY-B004
LEVEL
CONTOLLER
B B
1 4 5 3
C C
-4028
H05VVC4V5-K
10 m
5x0.5 1 2 3 4
+A009-X4 20 21 22 23
32.9 / GY+
32.9 / GY-
D
-4024 D
/32.0
H05VVC4V5-K
18x1.5 12 13
-X4 16 17
B004AO
E E
=EH001/100.7
A1
+F03
-KH008 A2
F
32.9 F
F0132_0V
12
14
11
=EH001/85.7
G G
LEVEL CONTROLLER
BOOM LUFFING
HYDRAULICS POS 9
32 34
Date 13.10.2011 2.2040 00EAD03 AE002
BOOM LUFFING HYDRAULICS LEVEL Stacker
Ed. by cw-de CONTROLLER + F04
Appr. VUNG ANG Page 33
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
=GR002+F02/20.1 35.1
F002_24VAUX F002_24VAUX
A A
B B
13 13 13 13 13 13
=EH001 =EH001 =EH001 =EH001 =EH001 =EH001
-K014 14
-K015 14
-K016 14
-K017 14
-K020 14
-K021 14
=EH001/102.5 =EH001/102.6 =EH001/102.7 =EH001/102.7 =EH001/103.1 =EH001/103.2
C C
=GR002+F02/20.2 35.1
D F002_0VAUX F002_0VAUX D
-PE
-X4 18 PE 19 20 21 22 23 24
-4029
H05VV5-F
20 m
12x1,5 1 GNYE 2 3 4 5 6 7
E E
+A009-X4 24 PE 25 26 PE 27 28 PE 29 30 PE 31 32 PE 33 34 PE 35
x1 x1 x1 x1 x1 x1
PE PE PE PE PE PE
F +GY-Y002 +GY-Y003 +GY-Y004 +GY-Y005 +GY-Y006 +GY-Y007 F
x2 x2 x2 x2 x2 x2
G G
33 35
Date 13.10.2011 2.2040 00EAD03 AE002
BOOM LUFFING HYDRAULICS Stacker
Ed. by cw-de VALVES + F04
Appr. VUNG ANG Page 34
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
A 34.9 / F002_24VAUX A
B B
13 13 13 13 13 13
=EH001 =EH001 =EH001 =EH001 =EH001 =EH001
-K022 14
-K023 14
-K024 14
-K025 14
-K026 14
-K027 14
=EH001/103.3 =EH001/103.4 =EH001/103.5 =EH001/103.6 =EH001/103.7 =EH001/103.7
C C
D D
34.9 / F002_0VAUX
-PE
-X4 25 PE 26 27 28 29 30 31
-4030
H05VV5-F
20 m
12x1,5 1 GNYE 2 3 4 5 6 7
E E
+A009-X4 36 PE 37 38 PE 39 40 PE 41 42 PE 43 44 PE 45 46 PE 47
-4052 -4053
Li9Y11Y-HF Li9Y11Y-HF
10 m 10 m
3x1 1 GNYE 2 3x1 1 GNYE 2
x1 x1
PE PE
F +GY-Y008 +GY-Y009 F
x2 x2
G G
34 36
Date 13.10.2011 2.2040 00EAD03 AE002
BOOM LUFFING HYDRAULICS Stacker
Ed. by cw-de VALVES + F04
Appr. VUNG ANG Page 35
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
=GR001/49.6 / F004_24V
A =GR001/49.7 / F004_0V A
B B
C C
PE
+F04-X4 32 33 PE
D D
-4038
H05VV5-F
35 m
3x1,5 1 2 GNYE
E =EH001/64.3 / PB_DP2 E
+X
-G002 UB GND PE DP_A
=EH001/63.3 -30°...+30° Profibus Address
24VDC
100mA 40
F INCLINATION F
SENSORS
BOOM LUFFING
POSITION
G G
35 =AP010+F02/37
Date 13.10.2011 2.2040 00EAD03 AE002
BOOM LUFFING INCLINATION Stacker
Ed. by cw-de SENSORS + F04
Appr. VUNG ANG Page 36
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
=AE002/30.8 / L1L400
TN-S 400V
L1L400 / 38.1
=AE002/30.8 / L2L400 L2L400 / 38.1
A =AE002/30.8 / L3L400 L3L400 / 38.1 A
=EH001+F04/87.1
I> I> I>
=EH001+F04/87.4 14
B
2 4 6 B
13 13
12 12
21
-Q003
=CH102+/107.5 22
11 11
C C
10 10
1 3 5
-Q003 9 9
/37.4 2 4 6
8 8
7 7
6 6
D D
5 5
4 4
13
-Q001
=EH001+F04/87.1 14
3 3
1 1,
E -Q003A1 / 38.1 E
2 2
A1 -Q003A2 / 38.2
-Q003
20kW A2 16 16
15 15
-X3 -PE
F 1 2 3 F
-1011 -X1 U1 V1 W1 PE
H07 RN-F
25 m 1 2 /37.1
4x2.5 BN BK GY GNYE
3 4 /37.2
U V W 5 6 /37.2
13 14 =EH001+F04/87.4
-M001
M 21 22 =CH102+/107.5
0,37 kW
3~
400V PE
50Hz
G IP55 G
RAIL
CLAMP 1
=AE002+F04/36 38
Date 13.10.2011 2.2040 00EAD03 AP010
RAIL CLAMP 1 MAIN CIRCUIT Stacker
Ed. by cw-de + F02
Appr. VUNG ANG Page 37
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
37.8 / L1L400
TN-S 400V
L1L400 / =AP020/40.1
37.8 / L2L400 L2L400 / =AP020/40.1
A 37.8 / L3L400 L3L400 / =AP020/40.1 A
1 3 5 13 21
+F02-7-Q002
0,63-1,0 A 14 22
(0,84)
=EH001+F04/87.2
I> I> I>
B
2 4 6 B
-PE
1 2
+F02-7-T002 +F02-7-XT001
0,16kVA
400V 3 4
110V
1 13 21
C +F02-7-F001 C
C 1A 2 14 22
=EH001+F04/87.3
+F02-7-X9 1 2
D D
E E
12 14
+F04-K005
=EH001+F04/101.6 11
37.8 / -Q003A1
37.8 / -Q003A2
F F
G G
37 +F04/39
Date 13.10.2011 2.2040 00EAD03 AP010
RAIL CLAMP 1 CONTROL CIRCUIT Stacker
Ed. by cw-de + F02
Appr. VUNG ANG Page 38
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
B B
13
=EH001
-K033 14
=EH001/104.4
C C
D D
-X4 1 2 PE
-4036
H05VV5-F
E E
25 m
3x1,5 1 2 GNYE
-B01 4 5 PE
JUNCTION BOX
RAIL CLAMP 1
F F
br
bn
G
RAIL CLAMP 1 G
SOLENOID
VALVE COIL
CLAMP OPEN
+F02/38 =AP020+F02/40
Date 13.10.2011 2.2040 00EAD03 AP010
RAIL CLAMP 1 VALVE Stacker
Ed. by cw-de + F04
Appr. VUNG ANG Page 39
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
=AP010/38.8 / L1L400
TN-S 400V
L1L400 / 41.1
=AP010/38.8 / L2L400 L2L400 / 41.1
A =AP010/38.8 / L3L400 L3L400 / 41.1 A
=EH001+F04/87.5
I> I> I>
=EH001+F04/87.7 14
B
2 4 6 B
13 13
12 12
21
-Q003
=CH102+/107.5 22
11 11
C C
10 10
1 3 5
-Q003 9 9
/40.4 2 4 6
8 8
7 7
6 6
D D
5 5
4 4
13
-Q001
=EH001+F04/87.5 14
3 3
1 1,
E -Q003A1 / 41.1 E
2 2
A1 -Q003A2 / 41.2
-Q003
20kW A2 16 16
15 15
-X3 -PE
F 1 2 3 F
-1012 -X1 U1 V1 W1 PE
H07 RN-F
25 m 1 2 /40.1
4x2.5 BN BK GY GNYE
3 4 /40.2
U V W 5 6 /40.2
13 14 =EH001+F04/87.7
-M001
M 21 22 =CH102+/107.5
0,37 kW
3~
400V PE
50Hz
G IP55 G
RAIL
CLAMP 2
=AP010+F04/39 41
Date 13.10.2011 2.2040 00EAD03 AP020
RAIL CLAMP 2 MAIN CIRCUIT Stacker
Ed. by cw-de + F02
Appr. VUNG ANG Page 40
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
40.8 / L1L400
TN-S 400V
L1L400 / =AE004/43.1
40.8 / L2L400 L2L400 / =AE004/43.1
A 40.8 / L3L400 L3L400 / =AE004/43.1 A
1 3 5 13 21
+F02-7-Q002
0,63-1,0 A 14 22
(0,84)
=EH001+F04/87.6
I> I> I>
B
2 4 6 B
-PE
1 2
+F02-7-T002 +F02-7-XT001
0,16kVA
400V 3 4
110V
1 13 21
C +F02-7-F001 C
C 1A 2 14 22
=EH001+F04/87.7
+F02-7-X9 1 2
D D
E E
12 14
+F04-K006
=EH001+F04/101.7 11
40.8 / -Q003A1
40.8 / -Q003A2
F F
G G
40 +F04/42
Date 13.10.2011 2.2040 00EAD03 AP020
RAIL CLAMP 2 CONTROL CIRCUIT Stacker
Ed. by cw-de + F02
Appr. VUNG ANG Page 41
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
A =AP010/39.8 / F003_24VAUX A
B B
13
=EH001
-K034 14
=EH001/104.5
C C
D D
=AP010/39.8 / F003_0VAUX
-PE
-X4 1 2 PE
-4037
H05VV5-F
E E
20 m
3x1,5 1 2 GNYE
-B02 4 5 PE
JUNCTION BOX
RAIL CLAMP 2
br
F F
bn
RAIL CLAMP 2
SOLENOID
VALVE COIL
G CLAMP OPEN G
+F02/41 =AE004+F02/43
Date 13.10.2011 2.2040 00EAD03 AP020
RAIL CLAMP 2 VALVE Stacker
Ed. by cw-de + F04
Appr. VUNG ANG Page 42
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
=AP020/41.8 / L1L400
TN-S 400V
L1L400 / 44.1
=AP020/41.8 / L2L400 L2L400 / 44.1
A =AP020/41.8 / L3L400 L3L400 / 44.1 A
=EH001+F04/89.1
I> I> I>
=EH001+F04/89.4 14
B
2 4 6 B
13 13
12 12
21
-Q003
=CH102+/107.2 22
11 11
C C
10 10
1 3 5
-Q003
/43.5 2 4 6
9 9
8 8
7 7
110VL1 / 44.3
D D
6 6
110VN1 / 44.3
5 5
4 4
13
-Q001
-K001 12 14 -S1 -T1 =EH001+F04/89.1 14
110-130VAC =EH001+F04/91.7 3 3
E E
11
-A1 -A2 -X1 -T2
1 1,
-Q003A1 / 44.1
A1 2 2
-Q003A2 / 44.2
-Q003
20kW A2
-1013 -X1 U1 V1 W1 PE 15 16
H07 RN-F
10 m
-4055 1 2 /43.1
13 14 =EH001+F04/89.4
M
21 22 =CH102+/107.2
+X-M001 3~
1,5 kW Θ
400V PE
G 50Hz G
IP55
CABLE
DRUM
=AP020+F04/42 44
Date 13.10.2011 2.2040 00EAD03 AE004
CABLE REEL MAIN CIRCUIT Stacker
Ed. by cw-de + F02
Appr. VUNG ANG Page 43
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
43.8 / L1L400
TN-S 400V
L1L400 / 45.1
43.8 / L2L400 L2L400 / 45.1
A 43.8 / L3L400 L3L400 / 45.1 A
1 3 5 13 21
+F02-7-Q002
0,63-1,0 A 14 22
(0,84)
=EH001+F04/89.2
I> I> I>
B
2 4 6 B
-PE
1 2
+F02-7-T002 +F02-7-XT001
0,16kVA
400V 3 4
110V
1 13 21
C +F02-7-F001 C
C 1A 2 14 22
=EH001+F04/89.3
+F02-7-X9 1 2
110VL1 / 43.8
110VN1 / 43.8
D D
=CH102+F03-X3 5
23
=CH102+F03-A002
=CH102+/106.8 24
=CH102+F03-X3 6
E E
12 14
+F04-K007
=EH001+F04/101.7 11
43.8 / -Q003A1
43.8 / -Q003A2
F F
G G
43 45
Date 13.10.2011 2.2040 00EAD03 AE004
CABLE REEL CONTROL CIRCUIT Stacker
Ed. by cw-de + F02
Appr. VUNG ANG Page 44
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
44.8 / L1L400
TN-S 400V
L1L400 / =GQ001+/46.1
44.8 / L2L400 L2L400 / =GQ001+/46.1
A 44.8 / L3L400 L3L400 / =GQ001+/46.1 A
1 13 21
B +F02-7-F002 B
B 6A 2 14 22
=EH001+F04/89.5
C C
-PE
D D
+F02-7-X2 1 2 PE
-1014
H07 RN-F
E E
10 m
3x1.5 BN BU GNYE
+X-E001 3 4 41 42
TFO PE
41
-T1 =EH001+F04/89.6
-T2 42
F F
100W
G G
TFO TFO THERMOSTAT
HEATER FOR INFORMATION
TEMPERATURE OK
44 =GQ001+/46
Date 13.10.2011 2.2040 00EAD03 AE004
CABLE REEL TFO HEATER Stacker
Ed. by cw-de + F02
Appr. VUNG ANG Page 45
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
=AE004+F02/45.8 / L1L400
TN-S 400V
=AE004+F02/45.8 / L2L400
A =AE004+F02/45.8 / L3L400 A
1 3 5 13 21
+F02-7-F01
C16 A 14 22
2 4 6
=EH001+F04/91.5
B B
C C
D D
=AE004+F02/45.8 / N_400
E E
-PE
F F
+F02-7-X1 1 2 3 4 PE
G
EXTERNAL G
POWER
SPARE
=AE004+F02/45 =GU002/47
Date 13.10.2011 2.2040 00EAD03 GQ001
EXTERNAL POWER SPARE Stacker
Ed. by cw-de +
Appr. VUNG ANG Page 46
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
=GS001+F01/16.3 / L1690VI
TN-S 690V
=GS001+F01/16.3 / L2690VI
A =GS001+F01/16.3 / L3690VI A
1 3 5
+F01-6-Q001
10-16 A
SET ???
I> I> I>
2 4 6 PE
B B
-1015 +F01-6-X1 1 2 3 PE
H07 RN-F
15 m
4x2.5 BN BK GY GNYE
+LC01-X1 1 2 3 PE
+LC01 1U 1V 1W
C -T001 PE C
15kVA
690/400V
IP31
Zzna0
D D
2W 2U 2V 2N
E E
-1016 +LC01-X1 4 5 6 7 PE
H07 RN-F
15 m
5x2.5 BN BK GY BL GNYE
+F01-6-X1 4 5 6 7 PE
-PE
N400VI / =GS002+F02/48.0
L1400VI / =GS002+F02/48.0
F L2400VI / =GS002+F02/48.0 F
L3400VI / =GS002+F02/48.0
G G
=GQ001/46 =GS002+F02/48
Date 13.10.2011 2.2040 00EAD03 GU002
AUXILARY TRANSFORMER Stacker
Ed. by cw-de +
Appr. VUNG ANG Page 47
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
=GU002+/47.8 / N400VI
TN-S 400V
=GU002+/47.8 / L1400VI
A =GU002+/47.8 / L2400VI A
=GU002+/47.8 / L3400VI
1 3 5
+F02-7-F001
B 32 A
2 4 6
B B
1 3 5 9
+F02-7-Q001
IDN 30mA
C C
IN 40 A IΔ
2 4 6 10
D D
E E
L1L400FI / =GR001+F04/49.1
L2L400FI / =GR001+F04/49.1
L3L400FI / =GR001+F04/49.1
F
NL_400FI / =GP001/52.1 F
G G
=GU002+/47 =GR001+F04/49
Date 13.10.2011 2.2040 00EAD03 GS002
AUXILARY FEEDER Stacker
Ed. by cw-de + F02
Appr. VUNG ANG Page 48
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
=GS002+F02/48.8 / L1L400FI
TN-S 400V
L1L400FI / =GP001+F02/52.1
=GS002+F02/48.8 / L2L400FI L2L400FI / =GP001+F02/52.1
A =GS002+F02/48.8 / L3L400FI L3L400FI / =GP001+F02/52.1 A
50.0
CONL+
B B
1 13 21 1 13 21 1 13 21 1 13 21 1 13 21
1 3 5
-F001 -F002 -F003 -F004 -F005
+F02-7-Q001 B 6A 2 14 22 B 6A 2 14 22 B 6A 2 14 22 B 6A 2 14 22 B 6A 2 14 22
6,3-10A (6,3)
=EH001/94.1
=EH001/94.2
=EH001/94.3
=EH001/94.4
=EH001/94.5
I> I> I>
2 4 6
+F02-7-X1 1 2 3
C C
+F04-X1 1 2 3
-PE
L1 L2 L3
-G001 3
24V DC
10A -X6
D D
+ -
50.0
CONL-
E E
-X4 1 2 3 4 5 6 7 8 9 10 11 12
=CH102+/106.0 / F001_24V
=CH102+/106.0 / F001_0V
=AE001+F01/26.0 / F0020_24V
=AE001+F01/22.2 / F0021_24V
=AE001+F01/26.0 / F0020_0V
=AE001+F01/22.2 / F0021_0V
=AE001+F01/27.1 / F003_24V
=AE001+F01/27.1 / F003_0V
=AE002/36.1 / F004_24V
=AE002/36.1 / F004_0V
=EH001/75.0 / F005_24V
=EH001/75.0 / F005_0V
F F
A A
49.8 51.0
CONL+ CONL+
B B
1 13 21 1 13 21 1 13 21 1 13 21 1 13 21 1 13 21 1 13 21 1 13 21
-F006 -F007 -F008 -F009 -F010 -F011 -F012 -F013
B 6A 2 14 22 B 6A 2 14 22 B 6A 2 14 22 B 6A 2 14 22 B 6A 2 14 22 B 6A 2 14 22 B 6A 2 14 22 B 6A 2 14 22
=EH001/94.6
=EH001/94.7
=EH001/94.7
=EH001/95.1
=EH001/95.2
=EH001/95.3
=EH001/91.6
=EH001/95.4
C C
D D
49.8 51.0
CONL- CONL-
E E
-X4 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 34 28 36
=EH001/78.0 / F006_24V
=EH001/78.0 / F006_0V
=EH001/79.0 / F007_24V
=EH001/79.0 / F007_0V
=EH001/83.0 / F008_24V
=EH001/83.0 / F008_0V
=EH001/89.0 / F009_24V
=EH001/89.0 / F009_0V
=EH001/91.0 / F010_24V
=EH001/91.0 / F010_0V
=EH001/93.0 / F011_24V
=EH001/93.0 / F011_0V
=EH001/94.0 / F012_24V
=EH001/94.0 / F012_0V
=EH001/99.0 / F0131_24V
=AE002/32.0 / F0132_24V
=EH001/100.0 / F0131_0V
=AE002/32.0 / F0132_0V
F F
TRIPPER CAR TRAVEL DRIVE BOOM LUFFING CABLE REEL E-HOUSE AIRCON EMERGENCY CHECKBACK ANALOG
G RAIL CLAMP EXTERNAL LIGHTS EXTERNAL SIGNAL INPUTS G
STORM LOCK E-STOP LCB'S DI
49 51
Date 13.10.2011 2.2040 00EAD03 GR001
24 V DC CONTROL VOLTAGE Stacker
Ed. by cw-de + F04
Appr. VUNG ANG Page 50
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
A A
50.9
CONL+
B B
1 13 21 1 13 21 1 13 21 1 13 21 1 13 21 1 13 21 1 13 21 1 13 21
-F014 -F015 -F016 -F017 -F018 -F019 -F020 -F021
B 6A 2 14 22 B 6A 2 14 22 B 6A 2 14 22 B 6A 2 14 22 B 6A 2 14 22 B 6A 2 14 22 B 6A 2 14 22 B 6A 2 14 22
=EH001/95.5
=EH001/95.6
=EH001/95.7
=EH001/95.7
=EH001/96.1
=EH001/96.2
=EH001/96.3
=EH001/96.4
C C
D D
50.9
CONL-
E E
-X4 29 30 31 32 33 35 37 38 39 40 41 42 43 44 45 46
=EH001/101.0 / F014_24V
=EH001/101.0 / F014_0V
=EH001/105.0 / F015_24V
=EH001/105.0 / F015_0V
==00EAC51=CL101+/140.1 / F016_24V
==00EAC51=CL101+/140.1 / F016_0V
=GS001+F01/16.6 / F017_24V
=GS001+F01/16.6 / F017_0V
F F
DIGITAL ANALOG TRIPPER CAR CHUTE MULTI- SPARE SPARE SPARE SPARE
G OUTPUTS OUTPUTS BLOCKED MONITORING & FUNCTIONAL G
LWL TRANSMITTER METER
PULL CORD SWITCH'S
50 =GP001+F02/52
Date 13.10.2011 2.2040 00EAD03 GR001
24 V DC CONTROL VOLTAGE Stacker
Ed. by cw-de + F04
Appr. VUNG ANG Page 51
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
=GR001+F04/49.8 / L1L400FI
TN-S 400V
L1L400FI / 53.1
=GR001+F04/49.8 / L2L400FI L2L400FI / 53.1
A =GR001+F04/49.8 / L3L400FI L3L400FI / 53.1 A
1 3 5
+F02-7-F001
B 10 A
2 4 6
B B
1 3 5
+F02-7-Q002
/54.1 2 4 6
C C
D D
-PE -PE
+F02-7-X1 1 2 2 3 PE 4 5 2 6 PE
F -1017 -1018 F
H07 RN-F H07 RN-F
30 m 30 m
5x2.5 BN BK GY BL GNYE 5x2.5 BN BK GY BL GNYE
55.0 / L1BE1
55.0 / L2BE1
55.0 / L3BE1
55.0 / NBE1
55.0 / PEBE1
56.0 / L1BE2
56.0 / L2BE2
56.0 / L3BE2
56.0 / NBE2
56.0 / PEBE2
G
EXTERNAL EXTERNAL G
LIGHTING LIGHTING
DIRECTION DIRECTION
BOOM TRIPPER CAR
=GR001+F04/51 53
Date 13.10.2011 2.2040 00EAD03 GP001
EXTERNAL LIGHTING MAIN Stacker
Ed. by cw-de FLUORESENT LAMPS + F02
Appr. VUNG ANG Page 52
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
52.8 / L1L400FI
TN-S 400V
L1L400FI / 54.1
52.8 / L2L400FI L2L400FI / 54.1
A 52.8 / L3L400FI L3L400FI / 54.1 A
1 1 1
B +F02-7-F002 +F02-7-F003 +F02-7-F004 B
B 6A 2 B 10A 2 B 6A 2
1
+F02-7-Q003
/54.2 2
C C
-PE
+F02-7-X2 5 6 PE
-1021
H07 RN-F
15 m
3x2.5 BN BU GNYE
D
+X 1 N PE D
-S001 1 3
2
2
-PE -PE
-1022
+F02-7-X2 1 PE 2 3 PE 4 H07 RN-F
15 m
-1019 -1020 3x2.5 BN BU GNYE
H07 RN-F H07 RN-F
30 m 30 m
BN GNYE BU BN GNYE BU
3x2.5 3x2.5 L
N
+X 1 PE 2 PE
-E27 +X
F F
400 W -X01
FLOOD
LIGHT
+X
-E28
58 W
G G
52 54
Date 18.10.2011 2.2040 00EAD03 GP001
EXTERNAL LIGHTING MAIN Stacker
Ed. by cw-de FLOODLIGHT STACKER + F02
Appr. VUNG ANG Page 53
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
53.8 / L1L400FI
TN-S 400V
L1L400FI / =AH001/57.1
53.8 / L2L400FI L2L400FI / =AH001/57.1
A 53.8 / L3L400FI L3L400FI / =AH001/57.1 A
1 3 5 13 21
+F02-7-Q001
0,4-0,63A 14 22
(0,46A)
=EH001+F04/92.1
I> I> I>
B
2 4 6 B
-PE
1 2
+F02-7-T001 +F02-7-XT001
0,16kVA
400V 3 4
110V
C C
1 13 21
+F02-7-F005
C 1A 2 14 22
=EH001+F04/92.2
D D
12 14 12 14
+F02-7-K030 +F02-7-K031
=EH001+F04/104.1 11 =EH001+F04/104.2 11
E E
A1 A1
+F02-7-Q002 +F02-7-Q003
4kW A2 4kW A2
F F
1 2 /52.1 1 2 /53.1
3 4 /52.2 3 4
5 6 /52.2 5 6
13 14 13 14
21 22 21 22
31 32 31 32
43 44 43 44
13X 14X 13X 14X
G G
21X 22X 21X 22X
EXTERNAL FLOODLIGHT
53 LIGHTING ON 55
Date 13.10.2011 2.2040 00EAD03 GP001
EXTERNAL LIGHTING CONTROL Stacker
Ed. by cw-de CIRCUIT + F02
Appr. VUNG ANG Page 54
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
A A
B B
+X +X +X +X +X +X +X +X
-E02 -E04 -E06 -E08 -E10 -E12 -E14 -E16
58 W L1 N PE 58 W L1 N PE 58 W L1 N PE 58 W L1 N PE 58 W L1 N PE 58 W L1 N PE 58 W L1 N PE 58 W L1 N PE
E E
F F
G
EXTERNAL G
LIGHTING
DIRECTION
BOOM
54 56
Date 18.10.2011 2.2040 00EAD03 GP001
EXTERNAL LIGHTING DIRECTION Stacker
Ed. by cw-de BOOM + F02
Appr. VUNG ANG Page 55
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
A A
B B
+X +X +X +X +X
-E18 -E20 -E22 -E24 -E26
58 W L1 N PE 58 W L1 N PE 58 W L1 N PE 58 W L1 N PE 58 W L1 N PE
E E
F F
G
EXTERNAL G
LIGHTING
DIRECTION
TRIPPER CAR
55 =AH001/57
Date 13.10.2011 2.2040 00EAD03 GP001
EXTERNAL LIGHTING DIRECTION Stacker
Ed. by cw-de TRIPPER CAR + F02
Appr. VUNG ANG Page 56
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
=GP001/54.8 / L1L400FI
TN-S 400V
L1L400FI / =AH002+/58.1
=GP001/54.8 / L2L400FI L2L400FI / =AH002+/58.1
A =GP001/54.8 / L3L400FI L3L400FI / =AH002+/58.1 A
1 3 5 13 21
+F02-7-F01
C16 A 14 22
2 4 6
=EH001+F04/91.1
B B
C C
D +F02-7-X1 1 2 3 4 PE D
-1047
H07 RN-F
15 m
5x2.5 BN BK GY BL GNYE
+X-A01
3180 W L1 L2 L3 N PE
6,9 A YT:11
AIR
-4040
/57.7
CONDITION H05VV5-F
E 10 m E
2x1,5 1
+F04-X4 1
general Temp
alarm >35°C Remote 12 14
ON/OFF =EH001
+F04-K032 11
=EH001+F04/104.3
-4040+F04-X4
2
2 1 5 4 /57.7
H05VV5-F
2x1,5 2
F =EH001+F04/91.2 =EH001+F04/91.3
F
3 6
YT:12
E-HOUSE
G
AIR G
CONDITION
=GP001/56 =AH002+/58
Date 13.10.2011 2.2040 00EAD03 AH001
AIRCON E-HOUSE Stacker
Ed. by cw-de + F02
Appr. VUNG ANG Page 57
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
=AH001+F02/57.8 / L1L400FI
TN-S 400V
L1L400FI / =AH003/59.1
=AH001+F02/57.8 / L2L400FI L2L400FI / =AH003/59.1
A =AH001+F02/57.8 / L3L400FI L3L400FI / =AH003/59.1 A
1 1 1 1
B +F02-7-F001 +F02-7-F002 +F02-7-F003 +F02-7-F004 B
B 6A 2 B 6A 2 B 6A 2 B 6A 2
+F02-7-X2 1 PE 2 3 PE 4 5 PE 6 7 PE 8
L NH N L NH N L NH N L NH N
+F01 +F02 +F03 +F04
-S001 1 4 5 -S002 1 4 5 -S003 1 4 5 -S004 1 4 5
TEMP. TEMP. TEMP. TEMP.
-SWITCH -SWITCH -SWITCH -SWITCH
θ θ θ θ
D D
2 3 2 3 2 3 2 3
E E
F F
1 1 1 1
+F01 PE +F02 PE +F03 PE +F04 PE
-E001 -E002 -E003 -E004
2 2 2 2
=AH001+F02/57 =AH003/59
Date 13.10.2011 2.2040 00EAD03 AH002
CABINET HEATINGS Stacker
Ed. by cw-de +
Appr. VUNG ANG Page 58
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
=AH002/58.8 / L1L400FI
TN-S 400V
L1L400FI / =EH001+F04/62.0
=AH002/58.8 / L2L400FI
A =AH002/58.8 / L3L400FI A
1 1 1
B +F02-7-F001 +F02-7-F002 +F02-7-F003 B
B 6A 2 B 6A 2 B 6A 2
PE
+F02-7-X2 5 6 PE
-1052
H07 RN-F
10 m
3x1.5 BN BU GNYE
C C
+LC01 -X2 1 2
L NH N L NH N
+F01 -S001
-S001 1 4 5 TEMP. 1 4 5
-SWITCH
TEMP.
-SWITCH
θ θ
D D
2 3 2 3
E E
PE PE
-1051
H07 RN-F
6m
3x1.5 BN BU GNYE
F F
1 2 1 2
+F03 M -M01
M +F03 +F04
-M01 1~ 19W 1~ -E01 -E02
150W
PE PE
G G
CABINET PANEL CABINET LIGHT CABINET LIGHT
VENTILATION VENTILATION CABINET 1 CABINET 2
1
=AH002/58 =EH001+F04/60
Date 13.10.2011 2.2040 00EAD03 AH003
CABINET VENTILATION Stacker
Ed. by cw-de +
Appr. VUNG ANG Page 59
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
A
SIMATIC S7-300 A
DP master
B B
IM 365
SEND
0 X1 0 0 X1 0 0 X1 0 0 X1 0 0 X1 0 0 X1 0 0 X1 0
1 1 1 1 1 1 1 1 1 1 1 1 1 1
2 2 2 2 2 2 2 2 2 2 2 2 2 2
3 3 3 3 3 3 3 3 3 3 3 3 3 3
4 4 4 4 4 4 4 4 4 4 4 4 4 4
5 5 5 5 5 5 5 5 5 5 5 5 5 5
C 6 6 6 6 6 6 6 6 6 6 6 6 6 6 C
7 7 7 7 7 7 7 7 7 7 7 7 7 7
0 0 0 0 0 0 0 0 0 0 0 0 0 0
1 1 1 1 1 1 1 1 1 1 1 1 1 1
D D
2 2 2 2 2 2 2 2 2 2 2 2 2 2
3 3 3 3 3 3 3 3 3 3 3 3 3 3
4 4 4 4 4 4 4 4 4 4 4 4 4 4
5 5 5 5 5 5 5 5 5 5 5 5 5 5
6 6 6 6 6 6 6 6 6 6 6 6 6 6
7 7 7 7 7 7 7 7 7 7 7 7 7 7
6ES7365-0BA01-0AA0
E E
F F
G G
=AH003+/59 61
Date 13.10.2011 2.2040 00EAD03 EH001
MAIN PLC OVERVIEW RACK 0 Stacker
Ed. by cw-de + F04
Appr. VUNG ANG Page 60
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
A A
-A12 -A13
-A11 /72.0 /74.0
C C
D D
E E
F F
G G
60 62
Date 13.10.2011 2.2040 00EAD03 EH001
MAIN PLC OVERVIEW RACK 1 Stacker
Ed. by cw-de + F04
Appr. VUNG ANG Page 61
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
=AH003+/59.8 / L1L400FI
TN-S 400V
=AH003+/59.8 / NL_400FI
A A
+F02-7-G001 +F02-7-G002
TRIO-UPS/1AC/24DC/ 5 MINI-BAT/24DC/1.3AH
PE L N L+ M BM - + - + -
B B
1 3 5
+F02-7-Q001
6,3-10A (6,3)
OPERATOR TOUCHPANEL PC
I> I> I>
2 4 6
+F02-7-XT001 +LC01
-A20
OPERATOR
1 TOUCHPANEL
C
+F02-7 A1 12 14 PC C
-PE
-F001 2
+F02-7 +F02-7
C 1A -K100 A2
-K100 11
/62.5
SHUT DOWN
PANEL PC
+ - 14
12 11 /62.5
D 24 D
22 21 /98.7
-PE
POWER SHUT ETHERNET
SUPPLY DOWN
PE L+ M A B
+F02-7-X4 1 2 3 4 5 6 7 PE PE PE 8 9
E
EHT E
+LC01-X4 PE 1 2 3 4
ETHERSW
64.3 / UPS+2
65.1 / UPS+3
98.7 / UPS+4
64.3 / UPS-2
65.1 / UPS-3
65.1
-4041
H05VV5-F
10 m
5x1,5 GNYE 1 2 4 3
F F
G G
61 63
Date 13.10.2011 2.2040 00EAD03 EH001
OPERATOR TOUCHPANEL PC Stacker
Ed. by cw-de + F04
Appr. VUNG ANG Page 62
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
A A
PB PB PB
Profibus DP Profibus DP Profibus DP
D D
=AE002
+X
-G002
=AE002/36.2
BOOM LUFFING
E POSITION E
INCLINATION
SENSORS
Profibus Address
40
-4105
Profibus SK
F 35 m F
2x0.64
PB
Profibus DP
G G
62 64
Date 13.10.2011 2.2040 00EAD03 EH001
PROFIBUS CONNECTIONS Stacker
Ed. by cw-de + F04
Appr. VUNG ANG Page 63
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
+F04-A02
/60.0
/63.0
A A
Rack 0
Slot 2
SIE.6ES7315-2EH14-0AB0
SIE.6ES7953-8LL20-0AA0
S7-300 SIEMENS
CPU 315-2 PN/DP
-X1:X1 PB
B
X1/MPI/DP PB_DP / =AE001+F01/22.4 B
MPI/DP
PB_DP2 / =AE002/36.5
-X2:X2
X2/PN ETHER / 65.1
PN
-X2.1:X2
X2/PN
PN
C C
D D
1
1/L+
L+
UPS+2 / 62.3
2
2/M
M
UPS-2 / 62.4
E E
F F
6ES7315-2EH13-0AB0
G G
63 65
Date 13.10.2011 2.2040 00EAD03 EH001
CPU 315-2 PN/DP Stacker
Ed. by cw-de + F04
Appr. VUNG ANG Page 64
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
A A
B B
-A200
64.3 / ETHER
EHT
C C
62.9 / ETHERSW
CH5 / ==00EAC51=CL101/141.5
CH6 / ==00EAC51=CL101/141.4
D D
62.3 / UPS+3 L1+
62.4 / UPS-3 M1
/96.5
F1
M2
L2+
F2
E E
=GS001
+A008-XF CH 1 CH 2 CH 3 CH 4 CH 5 CH 6
F F
G G
64 66
Date 13.10.2011 2.2040 00EAD03 EH001
SCALANCE X204-2 Stacker
Ed. by cw-de + F04
Appr. VUNG ANG Page 65
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
+F04-A04
/60.2
/75.0
/76.0
A /77.0 A
/78.0
Rack 0
Slot 4
SIE.6ES7321-1BL00-0AA0
SIE.6ES7392-1AM00-0AA0
S7-300 SIEMENS
SM 321 DI 32 x DC24V
B B
-X1:1 -X1:21
X1/1 X1/21
-X1:2 -X1:22
MAIN SWITCH ON =GS001+F01-6-Q000:11 /75.1 I0.0 I2.0 /77.1 =GU001+F01-4-Q001:11 MCB FEEDER TRANSFORMER OK
X1/2/IX.0 X1/22/IX+2.0
-X1:3 -X1:23 BOOM CONVEYOR PULL CORD SWITCH LEFT
MCB BOC OK ==00EAC03=AF001+F01-5-Q001:11 /75.2 I0.1 I2.1 /77.2 ==00EAC03=CH111+X-S001:14
SIDE
X1/3/IX.1 X1/23/IX+2.1
-X1:4 -X1:24
MCB BOC TRIPPED ==00EAC03=AF001+F01-5-Q001:05 /75.3 I0.2 I2.2 /77.3 ==00EAC03=CH112+X-S002:14 BOOM CONVEYOR PULL CORD SWITCH RIGHT SIDE
X1/4/IX.2 X1/24/IX+2.2
C -X1:5 -X1:25 C
MAIN BOC CONVEYOR CONTROL RELAY TRIPPED ==00EAC03=AF001+F01-5-K100:98 /75.4 I0.3 I2.3 /77.4 ==00EAC03=CG102+X-S001:12 BOOM CONVEYOR MISALIGNMENT SWITCHES WARNING
X1/5/IX.3 X1/25/IX+2.3
-X1:6 -X1:26
MCB BOC CONTROL TRANSFORMER OK ==00EAC03=AF001+F01-5-Q002:14 /75.5 I0.4 I2.4 /77.5 ==00EAC03=CG102+X-S001:32 BOOM CONVEYOR MISALIGNMENT SWITCHES ALARM
X1/6/IX.4 X1/26/IX+2.4
-X1:7 -X1:27
LCB BOC CONTROL VOLTAGE OK ==00EAC03=AF001+F01-5-F001:14 /75.6 I0.5 I2.5 /77.6 ==00EAC03=CS101+X-S001:3 BOOM CONVEYOR SPEED MONITOR
X1/7/IX.5 X1/27/IX+2.5
-X1:8 -X1:28
EARTH FAULT BOC ==00EAC03=AF001+F01-5-K003:11 /75.7 I0.6 I2.6 /77.7 ==00EAC03=CT101-S001:22 BOOM CONVEYOR TEMP. SWITCH ON FLUID COUPLING
X1/8/IX.6 X1/28/IX+2.6
-X1:9 -X1:29
MAIN CONTACTOR BOC ON ==00EAC03=AF001+F01-5-Q003:14 /75.7 I0.7 I2.7 /77.7 ==00EAC03=CG104+X-S001:BU BOOM CONVEYOR BRAKE OPEN
X1/9/IX.7 X1/29/IX+2.7
D -X1:10 -X1:30 D
X1/10 X1/30
-X1:11 -X1:31
X1/11 X1/31
-X1:12 -X1:32
MCB BCO BRAKE OK ==00EAC03=AF001+F02-Q004:14 /76.1 I1.0 I3.0 /78.1 ==00EAC51=CH121+X-S001:14 TRIPPER CAR PULL CORD SWITCH LEFT SIDE
X1/12/IX+1.0 X1/32/IX+3.0
-X1:13 -X1:33
MCB BCO BRAKE CONTROL TRANSFORMER OK==00EAC03=AF001+F02-7-Q005:14 /76.2 I1.1 I3.1 /78.2 ==00EAC51=CH122+X-S002:14 TRIPPER CAR PULL CORD SWITCH RIGHT SIDE
X1/13/IX+1.1 X1/33/IX+3.1
-X1:14 -X1:34
MCB BCO BRAKE CONTROL TRANSFORMER OK==00EAC03=AF001+F02-7-F002:14 /76.3 I1.2 I3.2 /78.3 ==00EAC51=CG106+X-S001:12 TRIPPER CAR MISALIGNMENT SWITCHES WARNING
X1/14/IX+1.2 X1/34/IX+3.2
E -X1:15 -X1:35 E
MAIN CONTACTOR BCO BRAKE ON ==00EAC03=AF001+F02-Q006:14 /76.4 I1.3 I3.3 /78.4 ==00EAC51=CG106+X-S001:32 TRIPPER CAR MISALIGNMENT SWITCHES ALARM
X1/15/IX+1.3 X1/35/IX+3.3
-X1:16 -X1:36
LOCAL BOOM CONVEYOR =CH101+X-S001:14 /76.5 I1.4 I3.4 /78.5 ==00EAC51=CL101+X-B001:4 TRIPPER CAR CHUTE BLOCKED MONITORING
X1/16/IX+1.4 X1/36/IX+3.4
-X1:17 -X1:37
REMOTE BOOM CONVEYOR =CH101+X-S001:24 /76.6 I1.5 I3.5 /78.6 =GU001+F01-3-Q002:14 SWITCH-DISCONNECTOR SECONDARY TRANSFORMER
X1/17/IX+1.5 X1/37/IX+3.5
-X1:18 -X1:38
START BOOM CONVEYOR =CH101+X-S002:14 /76.7 I1.6 I3.6 /78.7 ==00EAC51=CL101-U001:2 TRIPPER CAR PULL CORD SWITCH'S LWL TRANSMITTER OK
X1/18/IX+1.6 X1/38/IX+3.6
-X1:19 -X1:39
STOP BOOM CONVEYOR =CH101+X-S003:12 /76.7 I1.7 I3.7 /78.7 ==00EAC03=AF001+F01-5-F002:14LCB BOOM CONVEYOR STANDSTILL HEATER OK
X1/19/IX+1.7 X1/39/IX+3.7
F -X1:20 -X1:40 F
/76.8 X1/20/1M X1/40/2M /78.8
1M 2M
6ES7321-1BL00-0AA0
G G
65 67
Date 13.10.2011 2.2040 00EAD03 EH001
OVERVIEW Stacker
Ed. by cw-de DIGITAL INPUT BYTE 0-3 + F04
Appr. VUNG ANG Page 66
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
+F04-A05
/60.3
/79.0
/80.0
A /81.0 A
/82.0
Rack 0
Slot 5
SIE.6ES7321-1BL00-0AA0
SIE.6ES7392-1AM00-0AA0
S7-300 SIEMENS
SM 321 DI 32 x DC24V
B B
-X1:1 -X1:21
X1/1 X1/21
-X1:2 -X1:22
LOCAL TRAVEL DRIVE =CH111+X-S001:14 /79.1 I4.0 I6.0 /81.1 =CT111+F03-K001:11
PTC TRAVEL DRIVE MOTOR 1 OK
X1/2/IX.0 X1/22/IX+2.0
-X1:3 -X1:23
REMOTE TRAVEL DRIVE =CH111+X-S001:24 /79.2 I4.1 I6.1 /81.2 =CT112+F03-K002:11
PTC TRAVEL DRIVE MOTOR 2 OK
X1/3/IX.1 X1/23/IX+2.1
-X1:4 -X1:24
FORWARD TRAVEL DRIVE =CH111+X-S002:14 /79.3 I4.2 I6.2 /81.3 =CT113+F03-K003:11
PTC TRAVEL DRIVE MOTOR 3 OK
X1/4/IX.2 X1/24/IX+2.2
C -X1:5 -X1:25 C
BACKWARD TRAVEL DRIVE =CH111+X-S003:14 /79.4 I4.3 I6.3 /81.4 =CT114+F03-K004:11
PTC TRAVEL DRIVE MOTOR 4 OK
X1/5/IX.3 X1/25/IX+2.3
-X1:6 -X1:26
TRAVEL DRIVE MICRO SWITCH BRAKE M1 =CG111+X-S001:1 /79.5 I4.4 I6.4 /81.5 =AE001+F01-2-Q001:11
MSS TRAVEL DRIVE FREQUENCY CONVERTER OK
X1/6/IX.4 X1/26/IX+2.4
-X1:7 -X1:27
TRAVEL DRIVE MICRO SWITCH BRAKE M2 =CG111+X-S002:1 /79.6 I4.5 I6.5 /81.6 =AE001+F01-2-Q002:14
MSS TRAVEL DRIVE CONTROL TRANSFORMER OK
X1/7/IX.5 X1/27/IX+2.5
-X1:8 -X1:28
TRAVEL DRIVE MICRO SWITCH BRAKE M3 =CG111+X-S003:1 /79.7 I4.6 I6.6 /81.7 =AE001+F01-2-F001:14
LCB TRAVEL DRIVE CONTROL TRANSFORMER OK
X1/8/IX.6 X1/28/IX+2.6
-X1:9 -X1:29
TRAVEL DRIVE MICRO SWITCH BRAKE M4 =CG111+X-S004:1 /79.7 I4.7 I6.7 /81.7 =AE001+F01-2-Q003:14
MAIN CONTACTOR TRAVEL DRIVE OK
X1/9/IX.7 X1/29/IX+2.7
D -X1:10 -X1:30 D
X1/10 X1/30
-X1:11 -X1:31
X1/11 X1/31
-X1:12 -X1:32
OPERATION LIMIT AND REFERENCE POSITION 1 +X-S005:4 /80.1 I5.0 I7.0 /82.1 =AE001+F03-Q004:14
CONTACTOR TRAVEL DRIVE BRAKES ON
X1/12/IX+1.0 X1/32/IX+3.0
-X1:13 -X1:33
OPERATION LIMIT AND REFERENCE POSITION 2 +X-S006:4 /80.2 I5.1 I7.1 /82.2 =AE001+A010-F002:14
LCB TRAVEL DRIVE MOTOR 1 OK
X1/13/IX+1.1 X1/33/IX+3.1
-X1:14 -X1:34
ULTIMATE LIMIT FORWARD AND BACKWARD BIRDGED
=AE001+F01-S001:24 /80.3 I5.2 I7.2 /82.3 =AE001+A010-F003:14
LCB TRAVEL DRIVE MOTOR 2 OK
X1/14/IX+1.2 X1/34/IX+3.2
E -X1:15 -X1:35 E
MASCHINE COLLISION PROTECTION 1 =CG119+X-S002:14 /80.4 I5.3 I7.3 /82.4 =AE001+A010-F004:14
LCB TRAVEL DRIVE MOTOR 3 OK
X1/15/IX+1.3 X1/35/IX+3.3
-X1:16 -X1:36
MASCHINE COLLISION PROTECTION 2 =CG120+X-S003:14 /80.5 I5.4 I7.4 /82.5 =AE001+A010-F005:14
LCB TRAVEL DRIVE MOTOR 4 OK
X1/16/IX+1.4 X1/36/IX+3.4
-X1:17 -X1:37
ULTIMATE LIMIT FORWARD =CG117+X-S004:14 /80.6 I5.5 I7.5 /82.6 =AE001+F01-2-F006:14
LCB BRAKE TRAVEL MOTOR 1-4
X1/17/IX+1.5 X1/37/IX+3.5
-X1:18 -X1:38
ULTIMATE LIMIT BACKWARD =CG118+X-S005:14 /80.7 I5.6 I7.6 /82.7 =AE001+X-R001:T2 OVERTEMP BRAKE RESISTER
X1/18/IX+1.6 X1/38/IX+3.6
-X1:19 -X1:39
TRAVEL DRIVE ULTIMATE LIMIT AND MACHINE COLLISION RELAY OK
=AE001+F03-A001:14 /80.7 I5.7 I7.7 /82.7 -K011:21 CHECKBACK MASCHINE COLLISION PROTECTION 1 & 2 BRIDGED FOR OVERDRIFE RELAY
X1/19/IX+1.7 X1/39/IX+3.7
F -X1:20 -X1:40 F
/80.8 X1/20/1M X1/40/2M /82.8
1M 2M
6ES7321-1BL00-0AA0
G G
66 68
Date 13.10.2011 2.2040 00EAD03 EH001
OVERVIEW Stacker
Ed. by cw-de DIGITAL INPUT BYTE 4-7 + F04
Appr. VUNG ANG Page 67
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
+F04-A06
/60.4
/83.0
/84.0
A /85.0 A
/86.0
Rack 0
Slot 6
SIE.6ES7321-1BL00-0AA0
SIE.6ES7392-1AM00-0AA0
S7-300 SIEMENS
SM 321 DI 32 x DC24V
B B
-X1:1 -X1:21
X1/1 X1/21
-X1:2 -X1:22
MSS BOOM LUFFING HYDRAULIC MOTOR OK =AE002+F02-Q001:14 /83.1 I8.0 I10.0 /85.1 =AE002+F03-KH002:11PRESSURE SWITCH BOOM LUFFING HYDRAULICS POS 2.105 S1 OUT
X1/2/IX.0 X1/22/IX+2.0
-X1:3 -X1:23
MSS BOOM LUFFING HYDRAULICL CONTROL TRANSFORMER OK
=AE002+F02-7-Q002:14 /83.2 I8.1 I10.1 /85.2 =AE002+F03-KH003:11PRESSURE SWITCH BOOM LUFFING HYDRAULICS POS 2.105 S2 OUT
X1/3/IX.1 X1/23/IX+2.1
-X1:4 -X1:24
LCB BOOM LUFFING HYDRAULICL CONTROL TRANSFORMER OK=AE002+F02-7-F001:14 /83.3 I8.2 I10.2 /85.3 =AE002+F03-KH004:11PRESSURE SWITCH BOOM LUFFING HYDRAULICS POS 2.109 S1 OUT
X1/4/IX.2 X1/24/IX+2.2
C -X1:5 -X1:25 C
MAIN CONTACTOR BOOM LUFFING HYDRAULIC MOTOR OK =AE002+F02-Q003:14 /83.4 I8.3 I10.3 /85.4 =AE002+F03-KH005:11PRESSURE SWITCH BOOM LUFFING HYDRAULICS POS 2.109 S2 OUT
X1/5/IX.3 X1/25/IX+2.3
-X1:6 -X1:26
PTC BOOM LUFFING MOTOR OK =CT115+F02-K001:11 /83.5 I8.4 I10.4 /85.5 =AE002+F03-KH006:11PRESSURE SWITCH BOOM LUFFING HYDRAULICS POS 3.18 S1 OUT
X1/6/IX.4 X1/26/IX+2.4
-X1:7 -X1:27
PROPORTIONAL VALVE AMPLIFIER STATUS =AE002-K001:11 /83.6 I8.5 I10.5 /85.6 =AE002+F03-KH007:11PRESSURE SWITCH BOOM LUFFING HYDRAULICS POS 3.18 S2 OUT
X1/7/IX.5 X1/27/IX+2.5
-X1:8 -X1:28
MCB 24 V DC AUXILARY VOLTAGE TRANSFORMER
=GR002+F02-7-Q001:14 /83.7 I8.6 I10.6 /85.7 =AE002+F03-KH008:11LEVEL CONTROLLER BOOM LUFFING HYDRAULICS POS 3.18 S1 OUT
X1/8/IX.6 X1/28/IX+2.6
-X1:9 -X1:29
LCB BOOM LUFFING HYDRAULICS MOTOR COMPARTMENTHEATING=AE002+F02-7-F002:14 /83.7 I8.7 I10.7 /85.7 =CP121-S004:1 BOOM LUFFING HYDRAULICS POS 69 PRESSURE SWITCH
X1/9/IX.7 X1/29/IX+2.7
D -X1:10 -X1:30 D
X1/10 X1/30
-X1:11 -X1:31
X1/11 X1/31
-X1:12 -X1:32
LOCAL BOOM LUFFING =CH121+X-S004:14 /84.1 I9.0 I11.0 /86.1 -U1:1 BOOM LUFFING CONTAMINATION INDICATOR 100% POS 54
X1/12/IX+1.0 X1/32/IX+3.0
-X1:13 -X1:33
REMOTE BOOM LUFFING =CH121+X-S004:24 /84.2 I9.1 I11.1 /86.2 -U1:2 BOOM LUFFING HYDRAULICS CONTAMINATION INDICATOR 75% POS 54
X1/13/IX+1.1 X1/33/IX+3.1
-X1:14 -X1:34
UP BOOM LUFFING =CH121+X-S005:14 /84.3 I9.2 I11.2 /86.3 =AE002+A009-X4:57 BOOM LUFFING HYDRAULICS SPARE
X1/14/IX+1.2 X1/34/IX+3.2
E -X1:15 -X1:35 E
DOWN BOOM LUFFING =CH121+X-S006:14 /84.4 I9.3 I11.3 /86.4 =GR002+F02-7-F001:14
LCB BOOM LUFFING PROPORTIONAL VALVE AMPLIFIER
X1/15/IX+1.3 X1/35/IX+3.3
-X1:16 -X1:36
FINAL POSITION UPPER LIMIT +25,5° =CG121+X-S004:14 /84.5 I9.4 I11.4 /86.5 =GR002+F02-7-F002:14
LCB BOOM LUFFING HYDRAULICS -Y002 TILL -Y009 AND SPARE
X1/16/IX+1.4 X1/36/IX+3.4
-X1:17 -X1:37
FINAL POSITION LOWER LIMIT -16° =CG122+X-S005:14 /84.6 I9.5 I11.5 /86.6 =GR002+F02-7-F003:14
LCB 24 V DCRAIL CLAMP 1 & 2 SOLENOID VALVE COIL
X1/17/IX+1.5 X1/37/IX+3.5
-X1:18 -X1:38
OPERATON +24,5° =CG123+X-S006:14 /84.7 I9.6 I11.6 /86.7 =GR002+F02-7-F004:14
LCB 24 V DC AUXILARY VOLTAGE SPARE 1
X1/18/IX+1.6 X1/38/IX+3.6
-X1:19 -X1:39
SPARE -X10:98 /84.7 I9.7 I11.7 /86.7 =GR002+F02-7-F005:14
LCB 24 V DC AUXILARY VOLTAGE SPARE 2
X1/19/IX+1.7 X1/39/IX+3.7
F -X1:20 -X1:40 F
/84.8 X1/20/1M X1/40/2M /86.8
1M 2M
6ES7321-1BL00-0AA0
G G
67 69
Date 13.10.2011 2.2040 00EAD03 EH001
OVERVIEW Stacker
Ed. by cw-de DIGITAL INPUT BYTE 8-11 + F04
Appr. VUNG ANG Page 68
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
+F04-A07
/60.5
/87.0
/88.0
A /89.0 A
/90.0
Rack 0
Slot 7
SIE.6ES7321-1BL00-0AA0
SIE.6ES7392-1AM00-0AA0
S7-300 SIEMENS
SM 321 DI 32 x DC24V
B B
-X1:1 -X1:21
X1/1 X1/21
-X1:2 -X1:22
MSS RAIL CLAMP 1 MOTOR OK =AP010+F02-Q001:14 /87.1 I12.0 I14.0 /89.1 =AE004+F02-Q001:14 MSS CABLE REEL MOTOR OK
X1/2/IX.0 X1/22/IX+2.0
-X1:3 -X1:23
MSS RAIL CLAMP 1 CONTROL TRANSFORMER OK
=AP010+F02-7-Q002:14 /87.2 I12.1 I14.1 /89.2 =AE004+F02-7-Q002:14
MSS CABLE REEL CONTROL TRANSFORMER OK
X1/3/IX.1 X1/23/IX+2.1
-X1:4 -X1:24
LCB RAIL CLAMP 1 CONTROL TRANSFORMER OK=AP010+F02-7-F001:14 /87.3 I12.2 I14.2 /89.3 =AE004+F02-7-F001:14LCB CABLE REEL CONTROL TRANSFORMER OK
X1/4/IX.2 X1/24/IX+2.2
C -X1:5 -X1:25 C
MAIN CONTACTOR RAIL CLAMP 1 MOTOR OK =AP010+F02-Q003:14 /87.4 I12.3 I14.3 /89.4 =AE004+F02-Q003:14 MAIN CONTACTOR CABLE REEL OK
X1/5/IX.3 X1/25/IX+2.3
-X1:6 -X1:26
MSS RAIL CLAMP 2 MOTOR OK =AP020+F02-Q001:14 /87.5 I12.4 I14.4 /89.5 =AE004+F02-7-F002:14LCB TFO HEATER OK
X1/6/IX.4 X1/26/IX+2.4
-X1:7 -X1:27
MSS RAIL CLAMP 2 CONTROL TRANSFORMER OK
=AP020+F02-7-Q002:14 /87.6 I12.5 I14.5 /89.6 =AE004+X-E001:42 TFO THERMOSTAT FOR INFORMATION TEMPERATURE OK
X1/7/IX.5 X1/27/IX+2.5
-X1:8 -X1:28
LCB RAIL CLAMP 2 CONTROL TRANSFORMER OK=AP020+F02-7-F001:14 /87.7 I12.6 I14.6 /89.7 =CG140-S001:11 CABLE REEL LAST WINDING CW
X1/8/IX.6 X1/28/IX+2.6
-X1:9 -X1:29
MAIN CONTACTOR RAIL CLAMP 2 MOTOR OK =AP020+F02-Q003:14 /87.7 I12.7 I14.7 /89.7 =CG140-S002:21 CABLE REEL LAST WINDING CCW
X1/9/IX.7 X1/29/IX+2.7
D -X1:10 -X1:30 D
X1/10 X1/30
-X1:11 -X1:31
X1/11 X1/31
-X1:12 -X1:32
RAIL CLAMP 1 LOW OIL =AP010+X-B01:2 /88.1 I13.0 I15.0 /90.1 =CG150-S001 STORM LOCK BOLT 1 OPEN INI 1
X1/12/IX+1.0 X1/32/IX+3.0
-X1:13 -X1:33
RAIL CLAMP 1 HIGH TEMP. =AP010+X-B01:3 /88.2 I13.1 I15.1 /90.2 =CG151-S001 STORM LOCK BOLT 1 OPEN INI 2
X1/13/IX+1.1 X1/33/IX+3.1
-X1:14 -X1:34
RAIL CLAMP 1 LOW FLUID LEVEL SWITCH STOPS PUMP MOTOR =AP010+X-B01:6 /88.3 I13.2 I15.2 /90.3 =CG152-S001 STORM LOCK BOLT 2 OPEN INI 1
X1/14/IX+1.2 X1/34/IX+3.2
E -X1:15 -X1:35 E
RAIL CLAMP 1 STORM BRAKE RELEASED LIMIT SWITCH =AP010+X-B01:8 /88.4 I13.3 I15.3 /90.4 =CG153-S001 STORM LOCK BOLT 2 OPEN INI 2
X1/15/IX+1.3 X1/35/IX+3.3
-X1:16 -X1:36
RAIL CLAMP 2 LOW OIL =AP020+X-B02:2 /88.5 I13.4 I15.4 /90.5 =CG154-S001 STORM LOCK BOLT 3 OPEN INI 1
X1/16/IX+1.4 X1/36/IX+3.4
-X1:17 -X1:37
RAIL CLAMP 2 HIGH TEMP. =AP020+X-B02:3 /88.6 I13.5 I15.5 /90.6 =CG155-S001 STORM LOCK BOLT 3 OPEN INI 2
X1/17/IX+1.5 X1/37/IX+3.5
-X1:18 -X1:38
RAIL CLAMP 2 LOW FLUID LEVEL SWITCH STOPS PUMP MOTOR =AP020+X-B02:6 /88.7 I13.6 I15.6 /90.7 =CG156-S001 STORM LOCK BOLT 4 OPEN INI 1
X1/18/IX+1.6 X1/38/IX+3.6
-X1:19 -X1:39
RAIL CLAMP 2 STORM BRAKE RELEASED LIMIT SWITCH =AP020+X-B02:8 /88.7 I13.7 I15.7 /90.7 =CG157-S001 STORM LOCK BOLT 4 OPEN INI 2
X1/19/IX+1.7 X1/39/IX+3.7
F -X1:20 -X1:40 F
/88.8 X1/20/1M X1/40/2M /90.8
1M 2M
6ES7321-1BL00-0AA0
G G
68 70
Date 13.10.2011 2.2040 00EAD03 EH001
OVERVIEW Stacker
Ed. by cw-de DIGITAL INPUT 12-15 + F04
Appr. VUNG ANG Page 69
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
+F04-A09
/60.7
/95.0
/96.0
A /97.0 A
/98.0
Rack 0
Slot 9
SIE.6ES7321-1BL00-0AA0
SIE.6ES7392-1AM00-0AA0
S7-300 SIEMENS
SM 321 DI 32 x DC24V
B B
-X1:1 -X1:21
-X1:2 -X1:22
LCB DI CABLE REEL =GR001-F009:14 /95.1 I20.0 I22.0 /97.1 -X10:221 SPARE
-X1:3 -X1:23
LCB DI E-HOUSE AIRCON EXTERNAL LIGHTS =GR001-F010:14 /95.2 I20.1 I22.1 /97.2 -X10:222 SPARE
-X1:4 -X1:24
LCB DI EMERGENCY EXTERNAL E-STOP =GR001-F011:14 /95.3 I20.2 I22.2 /97.3 -X10:223 SPARE
C -X1:5 -X1:25 C
LCB DI ANALOG INPUTS =GR001-F013:14 /95.4 I20.3 I22.3 /97.4 -X10:224 SPARE
-X1:6 -X1:26
LCB DI DIGITAL OUTPUTS =GR001-F014:14 /95.5 I20.4 I22.4 /97.5 -X10:225 SPARE
-X1:7 -X1:27
LCB DI ANALOG OUTPUTS =GR001-F015:14 /95.6 I20.5 I22.5 /97.6 -X10:226 SPARE
-X1:8 -X1:28
LCB TRIPPER CAR CHUTE BLOCKED MONITORING =GR001-F016:14 /95.7 I20.6 I22.6 /97.7 -X10:227 SPARE
-X1:9 -X1:29
LCB DI MULTI- FUNCTIONAL METER =GR001-F017:14 /95.7 I20.7 I22.7 /97.7 -X10:228 SPARE
D -X1:10 -X1:30 D
-X1:11 -X1:31
-X1:12 -X1:32
LCB SPARE =GR001-F018:14 /96.1 I21.0 I23.0 /98.1 -X10:231 SPARE
-X1:13 -X1:33
LCB SPARE =GR001-F019:14 /96.2 I21.1 I23.1 /98.2 -X10:232 SPARE
-X1:14 -X1:34
LCB SPARE =GR001-F020:14 /96.3 I21.2 I23.2 /98.3 -X10:233 SPARE
E -X1:15 -X1:35 E
LCB SPARE =GR001-F021:14 /96.4 I21.3 I23.3 /98.4 -X10:234 SPARE
-X1:16 -X1:36
SCALANCE X204-2 FAULT -A200:F2 /96.5 I21.4 I23.4 /98.5 -X10:235 SPARE
-X1:17 -X1:37
RESET FAULTS +LC01-S001:14 /96.6 I21.5 I23.5 /98.6 -X10:236 SPARE
-X1:18 -X1:38
SPARE +LC01-X4:12 /96.7 I21.6 I23.6 /98.7 -X10:237 SPARE
-X1:19 -X1:39
SPARE -X10:218 /96.7 I21.7 I23.7 /98.7 +F02-7-K100:21 POWER BREAKDOWN PLC, SCALANCE AND PANEL PC ON UPS
F -X1:20 -X1:40 F
/96.8 /98.8
1M 2M
6ES7321-1BL00-0AA0
G G
69 71
Date 13.10.2011 2.2040 00EAD03 EH001
OVERVIEW Stacker
Ed. by cw-de DIGITAL INPUT 16-19 + F04
Appr. VUNG ANG Page 70
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
+F04-A08
/60.6
/91.0
/92.0
A /93.0 A
/94.0
Rack 0
Slot 8
SIE.6ES7321-1BL00-0AA0
SIE.6ES7392-1AM00-0AA0
S7-300 SIEMENS
SM 321 DI 32 x DC24V
B B
-X1:1 -X1:21
-X1:2 -X1:22
LCB E-HOUSE AIR CONDITION OK =AH001+F02-7-F01:14 /91.1 I16.0 I18.0 /93.1 =CH102+X-S001:14 E-STOP 1 PLACED ON BOOM CONVEYOR SQUEEZED
-X1:3 -X1:23
E-HOUSE AIR CONDITION GENERAL ALARM =AH001+X-A01:3 /91.2 I16.1 I18.1 /93.2 =CH112+X-S002:14 E-STOP 2 LADDER TO HYDRAULICS SQUEEZED
-X1:4 -X1:24
E-HOUSE AIR CONDITION TEMP>35°C =AH001+X-A01:6 /91.3 I16.2 I18.2 /93.3 =CH113+X-S003:14 E-STOP 3 STAIRS TO E-HOUSE
C -X1:5 -X1:25 C
MONITORING E-HOUSE DOOR CLOSED +X-S001:14 /91.4 I16.3 I18.3 /93.4 =CH114+X-S004:14 E-STOP 4 LADDER TO TRIPPERCAR
-X1:6 -X1:26
LCB EXTERNAL POWER SPARE=GQ001+F02-7-F01:14 /91.5 I16.4 I18.4 /93.5 =CH115+X-S005:14 E-STOP 5 MIDWAY TRIPPER CAR
-X1:7 -X1:27
LCB DI CHECKBACK SIGNAL LCB'S DI =GR001-F012:14 /91.6 I16.5 I18.5 /93.6 =CH122+X-S006:14 E-STOP 6 PLACED ON HYDRAULICS
-X1:8 -X1:28
PTC CABLE REEL MOTOR OK =AE004+F02-K001:11 /91.7 I16.6 I18.6 /93.7 =CH122+X-S007:14 E-STOP 7 E-HOUSE
-X1:9 -X1:29
SPARE -X10:168 /91.7 I16.7 I18.7 /93.7 =CH102+F03-A001:64 E-STOP RELAY TRIPPED
D -X1:10 -X1:30 D
-X1:11 -X1:31
-X1:12 -X1:32
MCB CONTROL TRANSFORMER EXTERNAL LIGHT
=GP001+F02-7-Q001:14 /92.1 I17.0 I19.0 /94.1 =GR001-F001:14 LCB DI EMERGENCY STOP RELAY
E -X1:15 -X1:35 E
LIGHT SWITCH 2 LOCATED STAIRS BOOM +X-S003:14 /92.4 I17.3 I19.3 /94.4 =GR001-F004:14 LCB DI BOOM LUFFING INCLINATION SENSORS
-X1:16 -X1:36
LIGHT SWITCH 3 LOCATED STAIRS TRIPPER CAR +X-S004:14 /92.5 I17.4 I19.4 /94.5 =GR001-F005:14 LCB DI BOOM CONVEYOR
-X1:17 -X1:37
SPARE -X10:176 /92.6 I17.5 I19.5 /94.6 =GR001-F006:14 LCB DI TRIPPER CAR
-X1:18 -X1:38
SPARE -X10:177 /92.7 I17.6 I19.6 /94.7 =GR001-F007:14 LCB DI TRAVEL DRIVE RAIL CLAMP STORM LOCK
-X1:19 -X1:39
SPARE -X10:178 /92.7 I17.7 I19.7 /94.7 =GR001-F008:14 LCB DI BOOM LUFFING
F -X1:20 -X1:40 F
/92.8 /94.8
1M 2M
6ES7321-1BL00-0AA0
G G
70 72
Date 13.10.2011 2.2040 00EAD03 EH001
OVERVIEW Stacker
Ed. by cw-de DIGITAL INPUT 20-23 + F04
Appr. VUNG ANG Page 71
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
+F04-A12
/99.0
/100.0
/61.2
A Rack 1 A
Slot 2
SIE.6ES7331-7KF02-0AB0
SIE.6ES7392-1AJ00-0AA0
S7-300 SIEMENS
SM 331 AI 8 x 12 BIT
-X1:1
B X1/1/L+ /99.1 B
L+
-X1:2
IW1.1 /99.1 =CG003+X-B01:I+ BOOM PILE COLLISION 1 (2 WIRE 4-20mA)
V X1/2/IWX/M0+_M0+
A -X1:3
IW1.2 /99.2 =CG003+X-B01:I-
X1/3/IWX/M0-_M0-
-X1:4
IW2.1 /99.3 =CG004+X-B02:I+ BOOM PILE COLLISION 2 (2 WIRE 4-20mA)
V X1/4/IWX+2/M1+_IC0+
A -X1:5
IW2.2 /99.4 =CG004+X-B02:I-
X1/5/IWX+2/M1-_IC0-
-X1:6
C IWX4.1 /99.5 =CG005+X-B03:I+ PILE DISTANCE BOOM LUFFING C
V X1/6/IWX+4/M2+_M1+
A -X1:7
IWX4.2 /99.6 =CG005+X-B03:I-
X1/7/IWX+4/M2-_M1-
-X1:8
IW6.1 /99.7 -X11:8 SPARE
V X1/8/IWX+6/M3+_IC1+
A -X1:9
IW6.2 /99.8 -X11:9
X1/9/IWX+6/M3-_IC1-
-X1:10
COMP+ /99.8
X1/10/COMP+_n.c.
-X1:11
D COMP- /100.1 D
X1/11/COMP-_Mana
-X1:12
IW8.1 /100.1 =CP001+GY-B001:5 PRESSURE SWITCH BOOM LUFFING HYDRAULICS POS 2.105
V X1/12/IWX+8/M4+_M2+
A -X1:13
IW8.2 /100.2 -A12:11
X1/13/IWX+8/M4-_M2-
-X1:14
IW10.1 /100.3 =CP002+GY-B002:5 PRESSURE SWITCH BOOM LUFFING HYDRAULICS POS 2.109
V X1/14/IWX+10/M5+_IC2+
A -X1:15
IW10.2 /100.4 -A12:13
X1/15/IWX+10/M5-_IC2-
-X1:16
E IW12.1 /100.5 =CP003+GY-B003:5 PRESSURE SWITCH BOOM LUFFING HYDRAULICS POS 3.18 E
V X1/16/IWX+12/M6+_M3+
A -X1:17
IW12.2 /100.6 -A12:15
X1/17/IWX+12/M6-_M3-
-X1:18
IW14.1 /100.7 =CL121+GY-B004:5 LEVEL CONTROLLER BOOM LUFFING HYDRAULICS POS 3.18
V X1/18/IWX+14/M7+_IC3+
A -X1:19
IW14.2 /100.8 -A12:17
X1/19/IWX+14/M7-_IC3-
-X1:20
X1/20/M /100.8
M
F F
6ES7331-7KF02-0AB0
G G
71 73
Date 13.10.2011 2.2040 00EAD03 EH001
OVERVIEW Stacker
Ed. by cw-de ANALOG INPUT 255-271 + F04
Appr. VUNG ANG Page 72
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
+F04-A10
/101.0
/102.0
/103.0
A /104.0 A
/60.8
Rack 0
Slot 10
SIE.6ES7322-1BL00-0AA0
SIE.6ES7392-1AM00-0AA0
S7-300 SIEMENS
SM 322 DO 32 x DC24V/0,5A
B B
-X1:1 -X1:21
/101.0 X1/1/1L+ X1/21/3L+ /103.0
1L+ 3L+
-X1:2 -X1:22
MAIN CONTACTOR BOMM CONVEYOR
==00EAC03=AF001+F01-5-K000:A1
ON /101.1 Q0.0 Q2.0 /103.1 -K020:A1 BOOM LUFFING HYDR. NORMAL OPERATION VALVE POS 2.25
X1/2/QX.0 X1/22/QX+2.0
-X1:3 -X1:23
BOOM CONVEYOR BRAKE ==00EAC03=AF001-K001:A1
OPEN /101.2 Q0.1 Q2.1 /103.2 -K021:A1 BOOM LUFFING HYDR. ENABLE EMERGENCY VALVE POS 2.25
X1/3/QX.1 X1/23/QX+2.1
-X1:4 -X1:24
BOOM CONVEYOR STANDSTILL==00EAC03=AF001+F01-5-K002:A1
HEATER ON /101.3 Q0.2 Q2.2 /103.3 -K022:A1 BOOM LUFFING HYDR. EMERGENCY VALVE LIFT POS 2.40
X1/4/QX.2 X1/24/QX+2.2
C -X1:5 -X1:25 C
TRAVEL DRIVE MAIN CONTACTOR ON=AE001+F01-2-K003:A1 /101.4 Q0.3 Q2.3 /103.4 -K023:A1 BOOM LUFFING HYDR. EMERGENCY VALVE LOWER POS 2.40
X1/5/QX.3 X1/25/QX+2.3
-X1:6 -X1:26
BOOM LUFFING HYDRAULICS MAIN CONTACTOR ON =AE002-K004:A1 /101.5 Q0.4 Q2.4 /103.5 -K024:A1 OPTOCOUPLER SPARE
X1/6/QX.4 X1/26/QX+2.4
-X1:7 -X1:27
RAIL CLAMP 1 MAIN CONTACTOR ON =AP010-K005:A1 /101.6 Q0.5 Q2.5 /103.6 -K025:A1 OPTOCOUPLER SPARE
X1/7/QX.5 X1/27/QX+2.5
-X1:8 -X1:28
RAIL CLAMP 2 MAIN CONTACTOR ON =AP020-K006:A1 /101.7 Q0.6 Q2.6 /103.7 -K026:A1 OPTOCOUPLER SPARE
X1/8/QX.6 X1/28/QX+2.6
-X1:9 -X1:29
CABLE DRUM MAIN CONTACTOR ON =AE004-K007:A1 /101.7 Q0.7 Q2.7 /103.7 -K027:A1 OPTOCOUPLER SPARE
X1/9/QX.7 X1/29/QX+2.7
D -X1:10 -X1:30 D
/101.8 X1/10/1M X1/30/3M /103.8
1M 3M
-X1:11 -X1:31
/102.0 X1/11/2L+ X1/31/4L+ /104.0
2L+ 4L+
-X1:12 -X1:32
QUIT E-STOP RELAY -K010:A1 /102.1 Q1.0 Q3.0 /104.1 =GP001+F02-7-K030:A1
EXTERNAL LIGHTING ON
X1/12/QX+1.0 X1/32/QX+3.0
-X1:13 -X1:33
MASCHINE COLLISION PROTECTION 1 & 2 BRIDGED FOR OVERDRIFE -K011:A1 /102.2 Q1.1 Q3.1 /104.2 =GP001+F02-7-K031:A1
FLOODLIGHT ON
X1/13/QX+1.1 X1/33/QX+3.1
QUIT TRAVEL DRIVE ULTIMATE LIMIT AND MACHINE -X1:14 -X1:34
-K012:A1 /102.3 Q1.2 Q3.2 /104.3 -K032:A1 E-HOUSE AIR CONDITION REMOTE ON/OFF
COLLISION RELAY
X1/14/QX+1.2 X1/34/QX+3.2
E -X1:15 -X1:35 E
BOOM LUFFING PROPORTIONAL VALVE AMPLIFIER ENABLE -K013:A1 /102.4 Q1.3 Q3.3 /104.4 -K033:A1 RAIL CLAMP 1 SOLENOID VALVE COIL CLAMP OPEN
X1/15/QX+1.3 X1/35/QX+3.3
-X1:16 -X1:36
BOOM LUFFING HYDR. LOAD FEEDBACK VALVE LOWER POS 2.51 -K014:A1 /102.5 Q1.4 Q3.4 /104.5 -K034:A1 RAIL CLAMP 2 SOLENOID VALVE COIL CLAMP OPEN
X1/16/QX+1.4 X1/36/QX+3.4
-X1:17 -X1:37
BOOM LUFFING HYDR. LOAD FEEDBACK VALVE LIFT POS 2.55 -K015:A1 /102.6 Q1.5 Q3.5 /104.6 +X-P001:1 WARNING LIGHT
X1/17/QX+1.5 X1/37/QX+3.5
-X1:18 -X1:38
BOOM LUFFING HYDR. LOAD HOLDING VALVE POS 2.64 -K016:A1 /102.7 Q1.6 Q3.6 /104.7 +X-P001:5 WARNING SOUNDER
X1/18/QX+1.6 X1/38/QX+3.6
-X1:19 -X1:39
BOOM LUFFING HYDR. PRESSURE BALANCE VALVE POS 2.14 -K017:A1 /102.7 Q1.7 Q3.7 /104.7 -K037:A1 SPARE RELAY
X1/19/QX+1.7 X1/39/QX+3.7
F -X1:20 -X1:40 F
/102.8 X1/20/2M X1/40/4M /104.8
2M 4M
6ES7322-1BL00-0AA0
G G
72 74
Date 13.10.2011 2.2040 00EAD03 EH001
OVERVIEW Stacker
Ed. by cw-de DIGITAL OUTPUTS 0-3 + F04
Appr. VUNG ANG Page 73
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
+F04-A13
/61.3
/105.0
A Rack 1 A
Slot 3
SIE.6ES7332-5HB01-0AB0
SIE.6ES7392-1AJ00-0AA0
S7-300 SIEMENS
SM 332 AO 2 x 12 BIT
-X1:1
B X1/1/L+ /105.0 B
L+
-X1:2
X1/2
-X1:3
QW1.1 /105.2 =AE002-U1:5 RATED VALUE PROPORTIONLA VALVE AMPLIFIER
X1/3/QWX/QI0_QV0
-X1:4
QW1.2 /105.3 -X21:3
X1/4/QWX/n.c._S0+
-X1:5
QW1.3 /105.3 -X21:4
X1/5/QWX/n.c._S0-
-X1:6
C X1/6/Mana0 /105.4 C
Mana0
-X1:7
QW2.1 /105.5 -X21:6 SPARE
X1/7/QWX+2/QI1_QV1
-X1:8
QW2.2 /105.5 -X21:7
X1/8/QWX+2/n.c._S1+
-X1:9
QW2.3 /105.6 -X21:8
X1/9/QWX+2/n.c._S1-
-X1:10
X1/10/Mana1 /105.7
Mana1
-X1:11
D X1/11 D
-X1:12
X1/12
-X1:13
X1/13
-X1:14
X1/14
-X1:15
X1/15
-X1:16
E X1/16 E
-X1:17
X1/17
-X1:18
X1/18
-X1:19
X1/19
-X1:20
X1/20/M /105.8
M
F F
6ES7332-5HB01-0AB0
G G
73 75
Date 13.10.2011 2.2040 00EAD03 EH001
OVERVIEW Stacker
Ed. by cw-de ANALOG OUTPUTS 255-258 + F04
Appr. VUNG ANG Page 74
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
=GR001/49.7 76.0
F005_24V F005_24V
A
=GR001/49.8 76.0 A
F005_0V F005_0V
-4042
/75.1 -X10 1+ 1- 2+ 2- 3+ 3- 4+ 4- 5+ 5- 6+ 6- 7+ 7- 8+ 8- 9+ 9- 10+ 10-
H05VV5-F
5m
1 2
-4043
2x1,5 /75.2
==00EAC03 H05VV5-F
5m
=AF001 9x1,5
B B
=GS001 +F01-5-X10 1
+F01 +F01-5-Q001
==00EAC03=AF001+F01/136.1
+F01-6-X10 1
XV XV XV XV
12 14 06 08
12 14 2 3 97 13 13 12 14 13
Q1 -S51 +F01-5 +F01-5 +F01-5 +F01-5 +F01-5
C +F01-6-Q000 C
=GS001+F01/16.1 11 1
-K100 98
-Q002 14
-F001 14
-K003 11
-Q003 14
==00EAC03=AF001+F01/136.8
==00EAC03=AF001+F01/136.3 ==00EAC03=AF001+F01/136.5 ==00EAC03=AF001+F01/136.5 ==00EAC03=AF001+F01/136.7
XV XV
11 05
D D
+F01-6-X10 2
+F01-5-X10 2 3 4 5 6 7 8
-4042 2 1 3 4 5 6 7 8
-4043
/75.2
-X10 1 H05VV5-F 2 3 4 5 6 7 8 9 10
9x1,5
E E
F F
+F04-A04
/66.3
-X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1
Rack 0
I0.0 I0.1 I0.2 I0.3 I0.4 I0.5 I0.6 I0.7
Slot 4 X1/2/IX.0 X1/3/IX.1 X1/4/IX.2 X1/5/IX.3 X1/6/IX.4 X1/7/IX.5 X1/8/IX.6 X1/9/IX.7
/66.3 /66.3 /66.3 /66.3 /66.3 /66.3 /66.3 /66.3
=GS001+F01-6-Q000:11==00EAC03=AF001+F01-5-Q001:11
==00EAC03=AF001+F01-5-Q001:05
==00EAC03=AF001+F01-5-K100:98
==00EAC03=AF001+F01-5-Q002:14
==00EAC03=AF001+F01-5-F001:14
==00EAC03=AF001+F01-5-K003:11
==00EAC03=AF001+F01-5-Q003:14
G G
MAIN SWITCH ON MCB BOC OK MCB BOC TRIPPED MAIN BOC CONVEYOR MCB BOC CONTROL LCB BOC CONTROL EARTH FAULT BOC MAIN CONTACTOR BOC
CONTROL RELAY TRIPPED TRANSFORMER OK VOLTAGE OK ON
74 76
Date 13.10.2011 2.2040 00EAD03 EH001
DIGITAL INPUT BYTE 0 MAIN Stacker
Ed. by cw-de SWITCH AND BOOM CONVEYOR + F04
Appr. VUNG ANG Page 75
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
75.9 77.0
F005_24V F005_24V
A
75.9 77.0 A
F005_0V F005_0V
-X10 11+ 11- 12+ 12- 13+ 13- 14+ 14- 15+ 15- 16+ 16- 17+ 17- 18+ 18- 19+ 19- 20+ 20-
-4044 -4045
/76.1 /76.5
H05VV5-F H05VV5-F
7m 40 m
7x1,5 2 7x1,5 2
B B
==00EAC03
=AF001+F02 -X1 4 -X10 1 3 -X1 14
=CH101+X
-X4 4 -X4 14
13 13 13 13 13 23 13 11
C -Q004 +F02-7-Q005 +F02-7-F002 -Q006 -S001 -S002 -S003 C
==00EAC03=AF001+F02/138.6 14 ==00EAC03=AF001+F02/139.1 14 ==00EAC03=AF001+F02/139.2 14 ==00EAC03=AF001+F02/138.6 14 14 24 green 14 red 12
-X4 -X4
3 13
D D
-4044 -4045
1 3 4 5 1 3 4 5
-X10 11 12 13 14 15 16 17 18 19 20
E E
F F
+F04-A04
/66.3
-X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 1M
Rack 0
I1.0 I1.1 I1.2 I1.3 I1.4 I1.5 I1.6 I1.7 X1/20/1M
Slot 4 X1/12/IX+1.0 X1/13/IX+1.1 X1/14/IX+1.2 X1/15/IX+1.3 X1/16/IX+1.4 X1/17/IX+1.5 X1/18/IX+1.6 X1/19/IX+1.7 /66.3
/66.3 /66.3 /66.3 /66.3 /66.3 /66.3 /66.3 /66.3
==00EAC03=AF001+F02-Q004:14
==00EAC03=AF001+F02-7-Q005:14
==00EAC03=AF001+F02-7-F002:14
==00EAC03=AF001+F02-Q006:14 =CH101+X-S001:14 =CH101+X-S001:24 =CH101+X-S002:14 =CH101+X-S003:12
G G
MCB BCO BRAKE OK MCB BCO BRAKE MCB BCO BRAKE MAIN CONTACTOR BCO LOCAL BOOM CONVEYOR REMOTE BOOM START BOOM CONVEYOR STOP BOOM CONVEYOR
CONTROL TRANSFORMER CONTROL TRANSFORMER BRAKE ON CONVEYOR
OK OK
75 77
Date 13.10.2011 2.2040 00EAD03 EH001
DIGITAL INPUT BYTE 1 BOOM Stacker
Ed. by cw-de CONVEYOR + F04
Appr. VUNG ANG Page 76
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
76.9
F005_24V
A
76.9 A
F005_0V
-X10 21+ 21- 22+ 22- 23+ 23- 24+ 24- 25+ 25- 26+ 26- 27+ 27- 28+ 28- 29+ 29- 30+ 30-
=GU001 1 ==00EAC03
+F01-4-X10 =CG101 ==00EAC03 ==00EAC03
+X
23 31 43 =CS101 =CG104
-S001 +X +X
24 32 44 -X10 1 2 -X10 1
==00EAC03
=CT101
-4050 -S001 BN
12 14 ==00EAC03 13 ==00EAC03 13 /77.4 21 13
=GU001 H05VV5-F
+ -
C =CH111 =CH112 -S001 -S001 C
+F01-4-Q001 5m
3 4
=GU001+F01/18.3
11 +X-S001 14 +X-S002 14 5x1,5
22 14
==00EAC03
BU
=CH102+/109.7 =CH102+/109.8
=CG102
+X
23 31 43
-S001
-X10 3 -X10 2
24 32 44
-4050
/77.4
H05VV5-F
5m
1 2
=GU001 2
5x1,5
D
+F01-4-X10 ==00EAC03 D
=CG101 1 2
+X
-S001
-4066 -4067
-4046 =CH102+/109.6 =CH102+/109.7 -4056 -4057 -4058
/77.1
H05VV5-F
H05VV5-F
40 m
H05VV5-F
40 m
-4049 /77.5
H05VV5-F
/77.6
H05VV5-F
/77.7
H05VV5-F
2x1,5 2 7x1,5 1 7x1,5 1 /77.4 1 3 4x1,5 1 3x1,5 1 3x1,5 1
-X10 21 22 23 24 25 26 27 28 29 30
E E
F F
+F04-A04
/66.3
-X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1
Rack 0
I2.0 I2.1 I2.2 I2.3 I2.4 I2.5 I2.6 I2.7
Slot 4 X1/22/IX+2.0 X1/23/IX+2.1 X1/24/IX+2.2 X1/25/IX+2.3 X1/26/IX+2.4 X1/27/IX+2.5 X1/28/IX+2.6 X1/29/IX+2.7
/66.6 /66.6 /66.6 /66.6 /66.6 /66.6 /66.6 /66.6
=GU001+F01-4-Q001:11 ==00EAC03=CH111+X-S001:14
==00EAC03=CH112+X-S002:14
==00EAC03=CG102+X-S001:12
==00EAC03=CG102+X-S001:32
==00EAC03=CS101+X-S001:3==00EAC03=CT101-S001:22==00EAC03=CG104+X-S001:BU
G G
MCB FEEDER BOOM CONVEYOR PULL BOOM CONVEYOR PULL BOOM CONVEYOR BOOM CONVEYOR BOOM CONVEYOR SPEED BOOM CONVEYOR TEMP. BOOM CONVEYOR BRAKE
TRANSFORMER OK CORD SWITCH LEFT SIDE CORD SWITCH RIGHT MISALIGNMENT MISALIGNMENT MONITOR SWITCH ON FLUID OPEN
SIDE SWITCHES WARNING SWITCHES ALARM COUPLING
76 78
Date 13.10.2011 2.2040 00EAD03 EH001
DIGITAL INPUT BYTE 2 BOOM Stacker
Ed. by cw-de CONVEYOR + F04
Appr. VUNG ANG Page 77
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
=GR001/50.0
F006_24V
A
=GR001/50.1 A
F006_0V
-X10 31+ 31- 32+ 32- 33+ 33- 34+ 34- 35+ 35- 36+ 36- 37+ 37- 38+ 38- 39+ 39- 40+ 40-
11 23 31 43
==00EAC51=CL101+/140.1
-S001
12 24 32 44
B01_5
-X10 31 32 33 34 35 36 37 38 39 40
E E
F F
+F04-A04
/66.3
-X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 2M
Rack 0
I3.0 I3.1 I3.2 I3.3 I3.4 I3.5 I3.6 I3.7 /66.6
Slot 4 X1/32/IX+3.0 X1/33/IX+3.1 X1/34/IX+3.2 X1/35/IX+3.3 X1/36/IX+3.4 X1/37/IX+3.5 X1/38/IX+3.6 X1/39/IX+3.7 X1/40/2M
/66.6 /66.6 /66.6 /66.6 /66.6 /66.6 /66.6 /66.6
==00EAC51=CH121+X-S001:14 ==00EAC51=CH122+X-S002:14
==00EAC51=CG106+X-S001:12
==00EAC51=CG106+X-S001:32
==00EAC51=CL101+X-B001:4 =GU001+F01-3-Q002:14 ==00EAC51=CL101-U001:2
==00EAC03=AF001+F01-5-F002:14
G G
TRIPPER CAR PULL CORD TRIPPER CAR PULL CORD TRIPPER CAR TRIPPER CAR TRIPPER CAR CHUTE SWITCH-DISCONNECTOR TRIPPER CAR PULL CORD LCB BOOM CONVEYOR
SWITCH LEFT SIDE SWITCH RIGHT SIDE MISALIGNMENT MISALIGNMENT BLOCKED MONITORING SECONDARY SWITCH'S LWL STANDSTILL HEATER OK
SWITCHES WARNING SWITCHES ALARM TRANSFORMER TRANSMITTER OK
77 79
Date 13.10.2011 2.2040 00EAD03 EH001
DIGITAL INPUT BYTE 3 TRIPPER Stacker
Ed. by cw-de CAR + F04
Appr. VUNG ANG Page 78
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
=GR001/50.1 80.0
F007_24V F007_24V
A
=GR001/50.2 80.0 A
F007_0V F007_0V
-4070 -X10 41+ 41- 42+ 42- 43+ 43- 44+ 44- -4071 45+ 45- 46+ 46- 47+ 47- 48+ 48- 49+ 49- 50+ 50-
/79.1 /79.5
H05VV5-F H05VV5-F
20 m 20 m
7x1,5 2 7x1,5 1
=AE001
B +A010 2 4 6 8 B
-X10
+X
13 23 13 13 2 4 2 4 2 4 2 4
=CG111 =CG111 =CG111 =CG111
C -S001 -S002 -S003 C
14 24 green 14 green 14
+X-S001 1
+X-S002 1
+X-S003 1
+X-S004 1
=AE001
D
+A010 1 3 5 7
D
-4070 -X10
/79.1
H05VV5-F
-4071
7x1,5 1 3 4 5 /79.5 2 3 4 5
-X10 41 42 43 44 45 46 47 48 49 50
E E
F F
+F04-A05
/67.3
-X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1
Rack 0
I4.0 I4.1 I4.2 I4.3 I4.4 I4.5 I4.6 I4.7
Slot 5 X1/2/IX.0 X1/3/IX.1 X1/4/IX.2 X1/5/IX.3 X1/6/IX.4 X1/7/IX.5 X1/8/IX.6 X1/9/IX.7
/67.3 /67.3 /67.3 /67.3 /67.3 /67.3 /67.3 /67.3
=CH111+X-S001:14 =CH111+X-S001:24 =CH111+X-S002:14 =CH111+X-S003:14 =CG111+X-S001:1 =CG111+X-S002:1 =CG111+X-S003:1 =CG111+X-S004:1
G G
LOCAL TRAVEL DRIVE REMOTE TRAVEL DRIVE FORWARD TRAVEL DRIVE BACKWARD TRAVEL TRAVEL DRIVE MICRO TRAVEL DRIVE MICRO TRAVEL DRIVE MICRO TRAVEL DRIVE MICRO
DRIVE SWITCH BRAKE M1 SWITCH BRAKE M2 SWITCH BRAKE M3 SWITCH BRAKE M4
78 80
Date 13.10.2011 2.2040 00EAD03 EH001
DIGITAL INPUT BYTE 4 TRAVEL Stacker
Ed. by cw-de DRIVE + F04
Appr. VUNG ANG Page 79
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
79.9 81.0
F007_24V F007_24V
A
79.9 81.0 A
F007_0V F007_0V
-X10 51+ 51- 52+ 52- 53+ 53- 54+ 54- 55+ 55- 56+ 56- 57+ 57- 58+ 58- 59+ 59- 60+ 60-
-4076 -4077
/80.1 /80.2
H05VV5-F H05VV5-F
25 m 25 m
3x1,5 2 3x1,5 2
B B
+LC01-X4 5
1 2 1 2
=AE001 23 13 13 13 13 13
+ - + -
=CG119 =CG120 =CG117 =CG118 =AE001
C +X-S005 +X-S006 +F01 C
+X-S002 +X-S003 +X-S004 +X-S005 +F03-A001
-S001 24 =AE001+F01/26.6
14 =AE001+F01/26.7
14 =AE001+F01/26.8
14 =AE001+F01/26.9
14 =AE001+F01/26.1
14
4 4
=AE001+F01/26.5
+LC01-X4 6
D D
-4076 -4077
/80.1 /80.2
H05VV5-F H05VV5-F
3x1,5 1 3x1,5 1
-X10 51 52 53 54 55 56 57 58 59 60
E E
F F
+F04-A05
/67.3
-X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 1M
Rack 0
I5.0 I5.1 I5.2 I5.3 I5.4 I5.5 I5.6 I5.7 X1/20/1M
Slot 5 X1/12/IX+1.0 X1/13/IX+1.1 X1/14/IX+1.2 X1/15/IX+1.3 X1/16/IX+1.4 X1/17/IX+1.5 X1/18/IX+1.6 X1/19/IX+1.7 /67.3
/67.3 /67.3 /67.3 /67.3 /67.3 /67.3 /67.3 /67.3
+X-S005:4 +X-S006:4 =AE001+F01-S001:24 =CG119+X-S002:14 =CG120+X-S003:14 =CG117+X-S004:14 =CG118+X-S005:14 =AE001+F03-A001:14
G G
OPERATION LIMIT AND OPERATION LIMIT AND ULTIMATE LIMIT MASCHINE COLLISION MASCHINE COLLISION ULTIMATE LIMIT ULTIMATE LIMIT TRAVEL DRIVE ULTIMATE
REFERENCE POSITION 1 REFERENCE POSITION 2 FORWARD AND PROTECTION 1 PROTECTION 2 FORWARD BACKWARD LIMIT AND MACHINE
BACKWARD BIRDGED COLLISION RELAY OK
79 81
Date 13.10.2011 2.2040 00EAD03 EH001
DIGITAL INPUT BYTE 5 TRAVEL Stacker
Ed. by cw-de DRIVE + F04
Appr. VUNG ANG Page 80
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
80.9 82.0
F007_24V F007_24V
A
80.9 82.0 A
F007_0V F007_0V
-X10 61+ 61- 62+ 62- 63+ 63- 64+ 64- 65+ 65- 66+ 66- 67+ 67- 68+ 68- 69+ 69- 70+ 70-
=AE001
B B
+F01-2-X10 1 2 3 4
12 14 12 14 12 14 12 14 12 14 13 13 13
=CT111 =CT112 =CT113 =CT114
C +F01-2-Q001 +F01-2-Q002 +F01-2-F001 +F01-2-Q003 C
+F03-K001 11
+F03-K002 11
+F03-K003 11
+F03-K004 11 =AE001+F01/21.1 11 =AE001+F01/21.6 14 =AE001+F01/21.6 14 =AE001+F01/21.5 14
=AE001+F01/23.1 =AE001+F01/23.5 =AE001+F01/24.1 =AE001+F01/24.5
+F01-2-X10 5 6 7 8
D D
-X10 61 62 63 64 65 66 67 68 69 70
E E
F F
+F04-A05
/67.3
-X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1
Rack 0
I6.0 I6.1 I6.2 I6.3 I6.4 I6.5 I6.6 I6.7
Slot 5 X1/22/IX+2.0 X1/23/IX+2.1 X1/24/IX+2.2 X1/25/IX+2.3 X1/26/IX+2.4 X1/27/IX+2.5 X1/28/IX+2.6 X1/29/IX+2.7
/67.6 /67.6 /67.6 /67.6 /67.6 /67.6 /67.6 /67.6
=CT111+F03-K001:11 =CT112+F03-K002:11 =CT113+F03-K003:11 =CT114+F03-K004:11 =AE001+F01-2-Q001:11 =AE001+F01-2-Q002:14 =AE001+F01-2-F001:14 =AE001+F01-2-Q003:14
G G
PTC TRAVEL DRIVE PTC TRAVEL DRIVE PTC TRAVEL DRIVE PTC TRAVEL DRIVE MSS TRAVEL DRIVE MSS TRAVEL DRIVE LCB TRAVEL DRIVE MAIN CONTACTOR
MOTOR 1 OK MOTOR 2 OK MOTOR 3 OK MOTOR 4 OK FREQUENCY CONVERTER CONTROL TRANSFORMER CONTROL TRANSFORMER TRAVEL DRIVE OK
OK OK OK
80 82
Date 13.10.2011 2.2040 00EAD03 EH001
DIGITAL INPUT BYTE 6 TRAVEL Stacker
Ed. by cw-de DRIVE + F04
Appr. VUNG ANG Page 81
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
81.9 87.0
F007_24V F007_24V
A
81.9 87.0 A
F007_0V F007_0V
-X10 71+ 71- 72+ 72- 73+ 73- 74+ 74- 75+ 75- 76+ 76- 77+ 77- 78+ 78- 79+ 79- 80+ 80-
-4078
/82.6
H05VV5-F
6m
3x1,5 2
B B
+A010 1 2 3 4
-X10
13 13 13 13 13 13 =AE001 T1 =EH001 22 24
=AE001 =AE001 =AE001 =AE001 =AE001 =AE001
C +X +F04 C
+F03-Q004 +A010-F002 +A010-F003 +A010-F004 +A010-F005 +F01-2-F006
=AE001+F01/22.8
14 =AE001+F01/23.2
14 =AE001+F01/23.7
14 =AE001+F01/24.2
14 =AE001+F01/24.7
14 =AE001+F01/25.1
14 -R001 T2 -K011 21
=AE001+F01/22.2 /102.2
+A010 5 6 7 8
-X10
D D
-4078
/82.6
H05VV5-F
3x1,5 1
-X10 71 72 73 74 75 76 77 78 79 80
E E
F F
+F04-A05
/67.3
-X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 2M
Rack 0
I7.0 I7.1 I7.2 I7.3 I7.4 I7.5 I7.6 I7.7 /67.6
Slot 5 X1/32/IX+3.0 X1/33/IX+3.1 X1/34/IX+3.2 X1/35/IX+3.3 X1/36/IX+3.4 X1/37/IX+3.5 X1/38/IX+3.6 X1/39/IX+3.7 X1/40/2M
/67.6 /67.6 /67.6 /67.6 /67.6 /67.6 /67.6 /67.6
=AE001+F03-Q004:14 =AE001+A010-F002:14 =AE001+A010-F003:14 =AE001+A010-F004:14 =AE001+A010-F005:14 =AE001+F01-2-F006:14 =AE001+X-R001:T2 -K011:21
G G
CONTACTOR TRAVEL LCB TRAVEL DRIVE LCB TRAVEL DRIVE LCB TRAVEL DRIVE LCB TRAVEL DRIVE LCB BRAKE TRAVEL OVERTEMP BRAKE CHECKBACK MASCHINE
DRIVE BRAKES ON MOTOR 1 OK MOTOR 2 OK MOTOR 3 OK MOTOR 4 OK MOTOR 1-4 RESISTER COLLISION PROTECTION
1 & 2 BRIDGED FOR
OVERDRIFE RELAY
81 83
Date 13.10.2011 2.2040 00EAD03 EH001
DIGITAL INPUT BYTE 7 TRAVEL Stacker
Ed. by cw-de DRIVE + F04
Appr. VUNG ANG Page 82
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
=GR001/50.2 84.0
F008_24V F008_24V
A
=GR001/50.3 84.0 A
F008_0V F008_0V
-X10 81+ 81- 82+ 82- 83+ 83- 84+ 84- 85+ 85- 86+ 86- 87+ 87- 88+ 88- 89+ 89- 90+ 90-
=AE002+F02
B B
13 13 13 13 12 14 12 14 13 =AE002 13
=CT115 =AE002 =GR002
C -Q001 +F02-7-Q002 +F02-7-F001 -Q003 +F02-7 C
-K001 -K001 +F02-7-Q001
=AE002+F02/28.6 14 =AE002+F02/29.1 14 =AE002+F02/29.2 14 =AE002+F02/28.6 14 =AE002+F02/28.3
11 =AE002/31.5
11 =GR002+F02/19.1
14 -F002 14
=AE002+F02/30.2
D D
-X10 81 82 83 84 85 86 87 88 89 90
E E
F F
+F04-A06
/68.3
-X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1
Rack 0
I8.0 I8.1 I8.2 I8.3 I8.4 I8.5 I8.6 I8.7
Slot 6 X1/2/IX.0 X1/3/IX.1 X1/4/IX.2 X1/5/IX.3 X1/6/IX.4 X1/7/IX.5 X1/8/IX.6 X1/9/IX.7
/68.3 /68.3 /68.3 /68.3 /68.3 /68.3 /68.3 /68.3
=AE002+F02-Q001:14 =AE002+F02-7-Q002:14 =AE002+F02-7-F001:14 =AE002+F02-Q003:14 =CT115+F02-K001:11 =AE002-K001:11 =GR002+F02-7-Q001:14 =AE002+F02-7-F002:14
G G
MSS BOOM LUFFING MSS BOOM LUFFING LCB BOOM LUFFING MAIN CONTACTOR BOOM PTC BOOM LUFFING PROPORTIONAL VALVE MCB 24 V DC AUXILARY LCB BOOM LUFFING
HYDRAULIC MOTOR OK HYDRAULICL CONTROL HYDRAULICL CONTROL LUFFING HYDRAULIC MOTOR OK AMPLIFIER STATUS VOLTAGE TRANSFORMER HYDRAULICS MOTOR
TRANSFORMER OK TRANSFORMER OK MOTOR OK COMPARTMENTHEATING
82 84
Date 13.10.2011 2.2040 00EAD03 EH001
DIGITAL INPUT BYTE 8 BOOM Stacker
Ed. by cw-de LUFFING + F04
Appr. VUNG ANG Page 83
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
83.9 85.0
F008_24V F008_24V
A
83.9 85.0 A
F008_0V F008_0V
-X10 91+ 91- 92+ 92- 93+ 93- 94+ 94- 95+ 95- 96+ 96- 97+ 97- 98+ 98- 99+ 99- 100+ 100-
==00EAD03
=CH121
+X
13 23 13 13 13 21 13 21 13 21
=CG121 =CG122 =CG123
C -S004 -S005 -S006 +X-S004 +X-S005 +X-S006
C
14 24 green 14 green 14 14 22 14 22 14 22
-X10 91 92 93 94 95 96 97 98 99 100
E E
F F
+F04-A06
/68.3
-X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 1M
Rack 0
I9.0 I9.1 I9.2 I9.3 I9.4 I9.5 I9.6 I9.7 X1/20/1M
Slot 6 X1/12/IX+1.0 X1/13/IX+1.1 X1/14/IX+1.2 X1/15/IX+1.3 X1/16/IX+1.4 X1/17/IX+1.5 X1/18/IX+1.6 X1/19/IX+1.7 /68.3
/68.3 /68.3 /68.3 /68.3 /68.3 /68.3 /68.3 /68.3
=CH121+X-S004:14 =CH121+X-S004:24 =CH121+X-S005:14 =CH121+X-S006:14 =CG121+X-S004:14 =CG122+X-S005:14 =CG123+X-S006:14 -X10:98
G G
LOCAL BOOM LUFFING REMOTE BOOM LUFFING UP BOOM LUFFING DOWN BOOM LUFFING FINAL POSITION UPPER FINAL POSITION LOWER OPERATON +24,5° SPARE
LIMIT +25,5° LIMIT -16°
83 85
Date 13.10.2011 2.2040 00EAD03 EH001
DIGITAL INPUT BYTE 9 BOOM Stacker
Ed. by cw-de LUFFING + F04
Appr. VUNG ANG Page 84
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
84.9 86.0
F008_24V F008_24V
A
84.9 86.0 A
F008_0V F008_0V
-X10 101+ 101- 102+ 102- 103+ 103- 104+ 104- 105+ 105- 106+ 106- 107+ 107- 108+ 108- 109+ 109- 110+ 110-
-4083
/85.7
H05VV5-F
50 m
3x1,5 1
B B
=AE002
+A009 48
-X4
12 14 12 14 12 14 12 14 12 14 12 14 12 14 2 3
C
=AE002 =AE002 =AE002 =AE002 =AE002 =AE002 =AE002 =CP121 P C
+F03-KH002 11
+F03-KH003 11
+F03-KH004 11
+F03-KH005 11
+F03-KH006 11
+F03-KH007 11
+F03-KH008 11
-S004 1
=AE002/32.1 =AE002/32.1 =AE002/32.4 =AE002/32.5 =AE002/32.7 =AE002/32.8 =AE002/33.1
PRESSURE
SWITCH
=AE002
+A009 49
D
-X4 D
-4083
/85.7
H05VV5-F
3x1,5 2
-X10 101 102 103 104 105 106 107 108 109 110
E E
F F
+F04-A06
/68.3
-X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1
Rack 0
I10.0 I10.1 I10.2 I10.3 I10.4 I10.5 I10.6 I10.7
Slot 6 X1/22/IX+2.0 X1/23/IX+2.1 X1/24/IX+2.2 X1/25/IX+2.3 X1/26/IX+2.4 X1/27/IX+2.5 X1/28/IX+2.6 X1/29/IX+2.7
/68.6 /68.6 /68.6 /68.6 /68.6 /68.6 /68.6 /68.6
=AE002+F03-KH002:11 =AE002+F03-KH003:11 =AE002+F03-KH004:11 =AE002+F03-KH005:11 =AE002+F03-KH006:11 =AE002+F03-KH007:11 =AE002+F03-KH008:11 =CP121-S004:1
G G
PRESSURE SWITCH PRESSURE SWITCH PRESSURE SWITCH PRESSURE SWITCH PRESSURE SWITCH PRESSURE SWITCH LEVEL CONTROLLER BOOM LUFFING
BOOM LUFFING BOOM LUFFING BOOM LUFFING BOOM LUFFING BOOM LUFFING BOOM LUFFING BOOM LUFFING HYDRAULICS POS 69
HYDRAULICS POS 2.105 HYDRAULICS POS 2.105 HYDRAULICS POS 2.109 HYDRAULICS POS 2.109 HYDRAULICS POS 3.18 S1 HYDRAULICS POS 3.18 S2 HYDRAULICS POS 3.18 S1 PRESSURE SWITCH
S1 OUT S2 OUT S1 OUT S2 OUT OUT OUT OUT
84 86
Date 13.10.2011 2.2040 00EAD03 EH001
DIGITAL INPUT BYTE 10 BOOM Stacker
Ed. by cw-de LUFFING + F04
Appr. VUNG ANG Page 85
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
85.9
F008_24V
A
85.9 A
F008_0V
-X10 111+ 111- 112+ 112- 113+ 113- 114+ 114- 115+ 115- 116+ 116- 117+ 117- 118+ 118- 119+ 119- 120+ 120-
B B
=AE002
-4084 +A009 50 52 53 55 56 58
/86.1
H05VV5-F -X4
50 m
7x1,5 1 3
V+ 0V
-U1
PNP 3 4
CONTAMINATION
INDICATOR
13 13 13 13 13
C
2 = ACTIVE =GR002 =GR002 =GR002 =GR002 =GR002 C
1 = ACTIVE
+F02-7-F001 14
+F02-7-F002 14
+F02-7-F003 14
+F02-7-F004 14
+F02-7-F005 14
=GR002+F02/20.1 =GR002+F02/20.2 =GR002+F02/20.3 =GR002+F02/20.4 =GR002+F02/20.5
1 2
100% 75%
=AE002
+A009 51 54 57
D
-X4 D
-4084
/86.1
H05VV5-F
7x1,5 2 4 5
-X10 111 112 113 114 115 116 117 118 119 120
E E
F F
+F04-A06
/68.3
-X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 2M
Rack 0
I11.0 I11.1 I11.2 I11.3 I11.4 I11.5 I11.6 I11.7 /68.6
Slot 6 X1/32/IX+3.0 X1/33/IX+3.1 X1/34/IX+3.2 X1/35/IX+3.3 X1/36/IX+3.4 X1/37/IX+3.5 X1/38/IX+3.6 X1/39/IX+3.7 X1/40/2M
/68.6 /68.6 /68.6 /68.6 /68.6 /68.6 /68.6 /68.6
-U1:1 -U1:2 =AE002+A009-X4:57 =GR002+F02-7-F001:14 =GR002+F02-7-F002:14 =GR002+F02-7-F003:14 =GR002+F02-7-F004:14 =GR002+F02-7-F005:14
G G
BOOM LUFFING BOOM LUFFING BOOM LUFFING LCB BOOM LUFFING LCB BOOM LUFFING LCB 24 V DCRAIL CLAMP LCB 24 V DC AUXILARY LCB 24 V DC AUXILARY
CONTAMINATION HYDRAULICS HYDRAULICS SPARE PROPORTIONAL VALVE HYDRAULICS -Y002 TILL 1 & 2 SOLENOID VALVE VOLTAGE SPARE 1 VOLTAGE SPARE 2
INDICATOR 100% POS 54 CONTAMINATION AMPLIFIER -Y009 AND SPARE COIL
INDICATOR 75% POS 54
85 87
Date 13.10.2011 2.2040 00EAD03 EH001
DIGITAL INPUT BYTE 11 BOOM Stacker
Ed. by cw-de LUFFING + F04
Appr. VUNG ANG Page 86
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
82.9 88.0
F007_24V F007_24V
A
82.9 88.0 A
F007_0V F007_0V
-X10 121+ 121- 122+ 122- 123+ 123- 124+ 124- 125+ 125- 126+ 126- 127+ 127- 128+ 128- 129+ 129- 130+ 130-
=AP010+F02 =AP020+F02
B B
13 13 13 13 13 13 13 13
C -Q001 +F02-7-Q002 +F02-7-F001 -Q003 -Q001 +F02-7-Q002 +F02-7-F001 -Q003 C
=AP010+F02/37.6 14 =AP010+F02/38.1 14 =AP010+F02/38.2 14 =AP010+F02/37.6 14 =AP020+F02/40.6 14 =AP020+F02/41.1 14 =AP020+F02/41.2 14 =AP020+F02/40.6 14
D D
-X10 121 122 123 124 125 126 127 128 129 130
E E
F F
+F04-A07
/69.3
-X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1
Rack 0
I12.0 I12.1 I12.2 I12.3 I12.4 I12.5 I12.6 I12.7
Slot 7 X1/2/IX.0 X1/3/IX.1 X1/4/IX.2 X1/5/IX.3 X1/6/IX.4 X1/7/IX.5 X1/8/IX.6 X1/9/IX.7
/69.3 /69.3 /69.3 /69.3 /69.3 /69.3 /69.3 /69.3
=AP010+F02-Q001:14 =AP010+F02-7-Q002:14 =AP010+F02-7-F001:14 =AP010+F02-Q003:14 =AP020+F02-Q001:14 =AP020+F02-7-Q002:14 =AP020+F02-7-F001:14 =AP020+F02-Q003:14
G G
MSS RAIL CLAMP 1 MSS RAIL CLAMP 1 LCB RAIL CLAMP 1 MAIN CONTACTOR RAIL MSS RAIL CLAMP 2 MSS RAIL CLAMP 2 LCB RAIL CLAMP 2 MAIN CONTACTOR RAIL
MOTOR OK CONTROL TRANSFORMER CONTROL TRANSFORMER CLAMP 1 MOTOR OK MOTOR OK CONTROL TRANSFORMER CONTROL TRANSFORMER CLAMP 2 MOTOR OK
OK OK OK OK
86 88
Date 13.10.2011 2.2040 00EAD03 EH001
DIGITAL INPUT BYTE 12 RAIL Stacker
Ed. by cw-de CLAMP + F04
Appr. VUNG ANG Page 87
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
87.9 90.0
F007_24V F007_24V
A
87.9 90.0 A
F007_0V F007_0V
-4085 -4086
/88.1 /88.5
H05VV5-F -X10 131+ 131- 132+ 132- 133+ 133- 134+ 134- H05VV5-F 135+ 135- 136+ 136- 137+ 137- 138+ 138- 139+ 139- 140+ 140-
25 m 25 m
7x1,5 2 7x1,5 2
=AP010+X-B01 =AP020+X-B02
JUNCTION BOX JUNCTION BOX
B RAIL CLAMP 1 RAIL CLAMP 2 B
1 7 9 1 7 9
BL BL BL BL BL BL BL BL
=CL131 =CT131 =CG131 =CG133 =CL132 =CT132 =CG132 =CG134
C Θ Θ C
-S001 -S002 BL
-S003 -S004 -S002 -S003 BL
-S004 -S005
BL BL BL BL BL BL
LOW OIL HIGH TEMP. LS-B(2ND STAGE) LS-A(1ST STAGE) LOW OIL HIGH TEMP. LS-B(2ND STAGE) LS-A(1ST STAGE)
2 3 6 8 2 3 6 8
D D
-4085 -4086
/88.1 /88.5
H05VV5-F H05VV5-F
7x1,5 1 3 4 5 7x1,5 1 3 4 5
-X10 131 132 133 134 135 136 137 138 139 140
E E
F F
+F04-A07
/69.3
-X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 1M
Rack 0
I13.0 I13.1 I13.2 I13.3 I13.4 I13.5 I13.6 I13.7 X1/20/1M
Slot 7 X1/12/IX+1.0 X1/13/IX+1.1 X1/14/IX+1.2 X1/15/IX+1.3 X1/16/IX+1.4 X1/17/IX+1.5 X1/18/IX+1.6 X1/19/IX+1.7 /69.3
/69.3 /69.3 /69.3 /69.3 /69.3 /69.3 /69.3 /69.3
=AP010+X-B01:2 =AP010+X-B01:3 =AP010+X-B01:6 =AP010+X-B01:8 =AP020+X-B02:2 =AP020+X-B02:3 =AP020+X-B02:6 =AP020+X-B02:8
G G
RAIL CLAMP 1 LOW OIL RAIL CLAMP 1 HIGH RAIL CLAMP 1 LOW RAIL CLAMP 1 STORM RAIL CLAMP 2 LOW OIL RAIL CLAMP 2 HIGH RAIL CLAMP 2 LOW RAIL CLAMP 2 STORM
TEMP. FLUID LEVEL SWITCH BRAKE RELEASED LIMIT TEMP. FLUID LEVEL SWITCH BRAKE RELEASED LIMIT
STOPS PUMP MOTOR SWITCH STOPS PUMP MOTOR SWITCH
87 89
Date 13.10.2011 2.2040 00EAD03 EH001
DIGITAL INPUT BYTE 13 RAIL Stacker
Ed. by cw-de CLAMP + F04
Appr. VUNG ANG Page 88
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
=GR001/50.4
F009_24V
A
=GR001/50.4 A
F009_0V
-X10 141+ 141- 142+ 142- 143+ 143- 144+ 144- 145+ 145- 146+ 146- 147+ 147- 148+ 148- 149+ 149- 150+ 150-
-4087
/89.6
B =AE004 H05VV5-F
B
10 m
+F02 5x1,5 2 4
=CG140
-X4 4 -X4 14
13 13 13 13 13 41 12 14 22 24
C -Q001 +F02-7-Q002 +F02-7-F001 -Q003 +F02-7-F002 +X-E001 -S001 -S002 C
=AE004+F02/43.6 14 =AE004+F02/44.1 14 =AE004+F02/44.2 14 =AE004+F02/43.6 14 =AE004+F02/45.2 14 =AE004+F02/45.2 CAM SWITCH 11 CAM SWITCH 21
42
-X4 -X4
3 13
-4087
-X1 3 -X10 2 4 -X1 13 -X10 6 /89.6
D H05VV5-F D
5x1,5 1 3
-X10 141 142 143 144 145 146 147 148 149 150
E E
F F
+F04-A07
/69.3
-X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1
Rack 0
I14.0 I14.1 I14.2 I14.3 I14.4 I14.5 I14.6 I14.7
Slot 7 X1/22/IX+2.0 X1/23/IX+2.1 X1/24/IX+2.2 X1/25/IX+2.3 X1/26/IX+2.4 X1/27/IX+2.5 X1/28/IX+2.6 X1/29/IX+2.7
/69.6 /69.6 /69.6 /69.6 /69.6 /69.6 /69.6 /69.6
=AE004+F02-Q001:14 =AE004+F02-7-Q002:14 =AE004+F02-7-F001:14 =AE004+F02-Q003:14 =AE004+F02-7-F002:14 =AE004+X-E001:42 =CG140-S001:11 =CG140-S002:21
G G
MSS CABLE REEL MOTOR MSS CABLE REEL LCB CABLE REEL MAIN CONTACTOR CABLE LCB TFO HEATER OK TFO THERMOSTAT FOR CABLE REEL LAST CABLE REEL LAST
OK CONTROL TRANSFORMER CONTROL TRANSFORMER REEL OK INFORMATION WINDING CW WINDING CCW
OK OK TEMPERATURE OK
88 90
Date 13.10.2011 2.2040 00EAD03 EH001
DIGITAL INPUT BYTE 14 CABLE REEL Stacker
Ed. by cw-de + F04
Appr. VUNG ANG Page 89
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
88.9
F007_24V
A
88.9 A
F007_0V
-X10 151+ 151- 152+ 152- 153+ 153- 154+ 154- 155+ 155- 156+ 156- 157+ 157- 158+ 158- 159+ 159- 160+ 160-
C
=CG150 + -
=CG151 + -
=CG152 + -
=CG153 + -
=CG154 + -
=CG155 + -
=CG156 + -
=CG157 + -
C
-S001 -S001 -S001 -S001 -S001 -S001 -S001 -S001
-X10 151 152 153 154 155 156 157 158 159 160
E E
F F
+F04-A07
/69.3
-X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 2M
Rack 0
I15.0 I15.1 I15.2 I15.3 I15.4 I15.5 I15.6 I15.7 /69.6
Slot 7 X1/32/IX+3.0 X1/33/IX+3.1 X1/34/IX+3.2 X1/35/IX+3.3 X1/36/IX+3.4 X1/37/IX+3.5 X1/38/IX+3.6 X1/39/IX+3.7 X1/40/2M
/69.6 /69.6 /69.6 /69.6 /69.6 /69.6 /69.6 /69.6
=CG150-S001 =CG151-S001 =CG152-S001 =CG153-S001 =CG154-S001 =CG155-S001 =CG156-S001 =CG157-S001
G G
STORM LOCK BOLT 1 STORM LOCK BOLT 1 STORM LOCK BOLT 2 STORM LOCK BOLT 2 STORM LOCK BOLT 3 STORM LOCK BOLT 3 STORM LOCK BOLT 4 STORM LOCK BOLT 4
OPEN INI 1 OPEN INI 2 OPEN INI 1 OPEN INI 2 OPEN INI 1 OPEN INI 2 OPEN INI 1 OPEN INI 2
89 91
Date 13.10.2011 2.2040 00EAD03 EH001
DIGITAL INPUT BYTE 15 STORM Stacker
Ed. by cw-de LOCK + F04
Appr. VUNG ANG Page 90
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
=GR001/50.5 92.0
F010_24V F010_24V
A
=GR001/50.5 92.0 A
F010_0V F010_0V
-X10 161+ 161- 162+ 162- 163+ 163- 164+ 164- 165+ 165- 166+ 166- 167+ 167- 168+ 168- 169+ 169- 170+ 170-
-4092 -4093
/91.2 /91.4
H05VV5-F H05VV5-F
15 m
2
15 m
2
==00EAD03
5x1,5 2x1,5
=AE004+F02
B B
=AH001 -X1 9 8
-X4 9 8
13 2 1 5 4 13 21 13 13 12 14
+F02-7 +X =GQ001 =GR001
C +X-A01 =AH001+F02/57.5 -K001 C
-F01 14 =AH001+F02/57.4 3 6
-S001 22
+F02-7-F01 14
-F012 14 =AE004+F02/43.3 11
=AH001+F02/57.4 14 =GQ001+/46.1 =GR001/50.7
-X4
5
-X1 5
D D
-4092 -4093
/91.2 /91.4
H05VV5-F H05VV5-F
5x1,5 1 3 2x1,5 1
-X10 161 162 163 164 165 166 167 168 169 170
E E
F F
+F04-A08
/71.3
-X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1
Rack 0
I16.0 I16.1 I16.2 I16.3 I16.4 I16.5 I16.6 I16.7
Slot 8 X1/2/IX.0 X1/3/IX.1 X1/4/IX.2 X1/5/IX.3 X1/6/IX.4 X1/7/IX.5 X1/8/IX.6 X1/9/IX.7
/71.3 /71.3 /71.3 /71.3 /71.3 /71.3 /71.3 /71.3
=AH001+F02-7-F01:14 =AH001+X-A01:3 =AH001+X-A01:6 +X-S001:14 =GQ001+F02-7-F01:14 =GR001-F012:14 =AE004+F02-K001:11 -X10:168
G G
LCB E-HOUSE AIR E-HOUSE AIR E-HOUSE AIR MONITORING E-HOUSE LCB EXTERNAL POWER LCB DI CHECKBACK PTC CABLE REEL MOTOR SPARE
CONDITION OK CONDITION GENERAL CONDITION TEMP>35°C DOOR CLOSED SPARE SIGNAL LCB'S DI OK
ALARM
90 92
Date 13.10.2011 2.2040 00EAD03 EH001
DIGITAL INPUT BYTE 16 E-HOUSE Stacker
Ed. by cw-de AIRCON + F04
Appr. VUNG ANG Page 91
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
91.9
F010_24V
A
91.9 A
F010_0V
-X10 171+ 171- 172+ 172- 173+ 173- 174+ 174- 175+ 175- 176+ 176- 177+ 177- 178+ 178- 179+ 179- 180+ 180-
B B
-4094 -4095 -4096
/92.3 /92.4 /92.5
H05VV5-F H05VV5-F H05VV5-F
25 m 15 m 50 m
2x1,5 2 2x1,5 2 2x1,5 2
13 13 13 13 13
C
=GP001 =GP001 +X +X +X C
+F02-7-Q001 14
+F02-7-F005 14
-S002 14
-S003 14
-S004 14
=GP001+F02/54.1 =GP001+F02/54.2
LIGHT LIGHT LIGHT
SWITCH 1 SWITCH 2 SWITCH 3
D D
-X10 171 172 173 174 175 176 177 178 179 180
E E
F F
+F04-A08
/71.3
-X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 1M
Rack 0
I17.0 I17.1 I17.2 I17.3 I17.4 I17.5 I17.6 I17.7 X1/20/1M
Slot 8 X1/12/IX+1.0 X1/13/IX+1.1 X1/14/IX+1.2 X1/15/IX+1.3 X1/16/IX+1.4 X1/17/IX+1.5 X1/18/IX+1.6 X1/19/IX+1.7 /71.3
/71.3 /71.3 /71.3 /71.3 /71.3 /71.3 /71.3 /71.3
=GP001+F02-7-Q001:14 =GP001+F02-7-F005:14 +X-S002:14 +X-S003:14 +X-S004:14 -X10:176 -X10:177 -X10:178
G G
MCB CONTROL LCB CONTROL LIGHT SWITCH 1 LIGHT SWITCH 2 LIGHT SWITCH 3 SPARE SPARE SPARE
TRANSFORMER TRANSFORMER LOCATED LADDER LOCATED STAIRS BOOM LOCATED STAIRS
EXTERNAL LIGHT EXTERNAL LIGHT HYDRAULICS TRIPPER CAR
91 93
Date 13.10.2011 2.2040 00EAD03 EH001
DIGITAL INPUT BYTE 17 EXTERNAL Stacker
Ed. by cw-de LIGHTS + F04
Appr. VUNG ANG Page 92
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
=GR001/50.6
F011_24V
A
=GR001/50.6 A
F011_0V
-X10 181+ 181- 182+ 182- 183+ 183- 184+ 184- 185+ 185- 186+ 186- 187+ 187- 188+ 188- 189+ 189- 190+ 190-
+LC01-X4 7
+LC01-X4 8
D D
-4059 -4060 -4061 -4062 -4063 -4064 -4065
=CH102+/108.1 =CH102+/108.3 =CH102+/108.5 =CH102+/108.7 =CH102+/109.1 =CH102+/109.3 =CH102+/109.4
H05VV5-F H05VV5-F H05VV5-F H05VV5-F H05VV5-F H05VV5-F H05VV5-F
30 m 25 m 15 m 45 m 30 m 20 m 15 m
7x1,5 1 7x1,5 1 7x1,5 1 7x1,5 1 7x1,5 1 7x1,5 1 7x1,5 1
-X10 181 182 183 184 185 186 187 188 189 190
E E
F F
+F04-A08
/71.3
-X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1
Rack 0
I18.0 I18.1 I18.2 I18.3 I18.4 I18.5 I18.6 I18.7
Slot 8 X1/22/IX+2.0 X1/23/IX+2.1 X1/24/IX+2.2 X1/25/IX+2.3 X1/26/IX+2.4 X1/27/IX+2.5 X1/28/IX+2.6 X1/29/IX+2.7
/71.6 /71.6 /71.6 /71.6 /71.6 /71.6 /71.6 /71.6
=CH102+X-S001:14 =CH112+X-S002:14 =CH113+X-S003:14 =CH114+X-S004:14 =CH115+X-S005:14 =CH122+X-S006:14 =CH122+X-S007:14 =CH102+F03-A001:64
G G
E-STOP 1 PLACED ON E-STOP 2 LADDER TO E-STOP 3 STAIRS TO E-STOP 4 LADDER TO E-STOP 5 MIDWAY E-STOP 6 PLACED ON E-STOP 7 E-HOUSE E-STOP RELAY TRIPPED
BOOM CONVEYOR HYDRAULICS SQUEEZED E-HOUSE TRIPPERCAR TRIPPER CAR HYDRAULICS
SQUEEZED
92 94
Date 13.10.2011 2.2040 00EAD03 EH001
DIGITAL INPUT BYTE 18 Stacker
Ed. by cw-de EMERGENCY EXTERNAL E-STOP + F04
Appr. VUNG ANG Page 93
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
=GR001/50.7 95.0
F012_24V F012_24V
A
=GR001/50.7 95.0 A
F012_0V F012_0V
-X10 191+ 191- 192+ 192- 193+ 193- 194+ 194- 195+ 195- 196+ 196- 197+ 197- 198+ 198- 199+ 199- 200+ 200-
B B
13 13 13 13 13 13 13 13
C
=GR001 =GR001 =GR001 =GR001 =GR001 =GR001 =GR001 =GR001 C
-F001 14
-F002 14
-F003 14
-F004 14
-F005 14
-F006 14
-F007 14
-F008 14
=GR001/49.3 =GR001/49.4 =GR001/49.6 =GR001/49.7 =GR001/49.8 =GR001/50.1 =GR001/50.2 =GR001/50.3
D D
-X10 191 192 193 194 195 196 197 198 199 200
E E
F F
+F04-A08
/71.3
-X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 2M
Rack 0
I19.0 I19.1 I19.2 I19.3 I19.4 I19.5 I19.6 I19.7 /71.6
Slot 8 X1/32/IX+3.0 X1/33/IX+3.1 X1/34/IX+3.2 X1/35/IX+3.3 X1/36/IX+3.4 X1/37/IX+3.5 X1/38/IX+3.6 X1/39/IX+3.7 X1/40/2M
/71.6 /71.6 /71.6 /71.6 /71.6 /71.6 /71.6 /71.6
=GR001-F001:14 =GR001-F002:14 =GR001-F003:14 =GR001-F004:14 =GR001-F005:14 =GR001-F006:14 =GR001-F007:14 =GR001-F008:14
G G
LCB DI EMERGENCY LCB DI TRAVEL DRIVE LCB DI TRAVEL DRIVE LCB DI BOOM LUFFING LCB DI BOOM CONVEYOR LCB DI TRIPPER CAR LCB DI TRAVEL DRIVE LCB DI BOOM LUFFING
STOP RELAY ULTIMATE LIMIT POSTION ENCODER INCLINATION SENSORS RAIL CLAMP STORM LOCK
MACHINE COLLISION
FREQUENCY CONVERTER
93 95
Date 13.10.2011 2.2040 00EAD03 EH001
DIGITAL INPUT BYTE 19 Stacker
Ed. by cw-de CHECKBACK SIGNAL LCB'S DI + F04
Appr. VUNG ANG Page 94
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
94.9 96.0
F012_24V F012_24V
A
94.9 96.0 A
F012_0V F012_0V
-X10 201+ 201- 202+ 202- 203+ 203- 204+ 204- 205+ 205- 206+ 206- 207+ 207- 208+ 208- 209+ 209- 210+ 210-
B B
13 13 13 13 13 13 13 13
C
=GR001 =GR001 =GR001 =GR001 =GR001 =GR001 =GR001 =GR001 C
-F009 14
-F010 14
-F011 14
-F013 14
-F014 14
-F015 14
-F016 14
-F017 14
=GR001/50.4 =GR001/50.5 =GR001/50.6 =GR001/50.8 =GR001/51.1 =GR001/51.2 =GR001/51.3 =GR001/51.4
D D
-X10 201 202 203 204 205 206 207 208 209 210
E E
F F
+F04-A09
/70.3
-X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1
Rack 0
I20.0 I20.1 I20.2 I20.3 I20.4 I20.5 I20.6 I20.7
Slot 9 X1/2/IX.0 X1/3/IX.1 X1/4/IX.2 X1/5/IX.3 X1/6/IX.4 X1/7/IX.5 X1/8/IX.6 X1/9/IX.7
/70.3 /70.3 /70.3 /70.3 /70.3 /70.3 /70.3 /70.3
=GR001-F009:14 =GR001-F010:14 =GR001-F011:14 =GR001-F013:14 =GR001-F014:14 =GR001-F015:14 =GR001-F016:14 =GR001-F017:14
G G
LCB DI CABLE REEL LCB DI E-HOUSE AIRCON LCB DI EMERGENCY LCB DI ANALOG INPUTS LCB DI DIGITAL OUTPUTS LCB DI ANALOG OUTPUTS LCB TRIPPER CAR CHUTE LCB DI MULTI-
EXTERNAL LIGHTS EXTERNAL E-STOP BLOCKED MONITORING FUNCTIONAL METER
94 96
Date 13.10.2011 2.2040 00EAD03 EH001
DIGITAL INPUT BYTE 20 DIGITAL Stacker
Ed. by cw-de INPUT BYTE 19 CHECKBACK SIGNAL + F04
Appr. VUNG ANG LCB'S DI Page 95
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
95.9 97.0
F012_24V F012_24V
A
95.9 97.0 A
F012_0V F012_0V
-X10 211+ 211- 212+ 212- 213+ 213- 214+ 214- 215+ 215- 216+ 216- 217+ 217- 218+ 218- 219+ 219- 220+ 220-
-4097
/96.5
H05VV5-F
15 m
5x1,5 2 4
B B
+LC01-X4 9 11
13 13 13 13 F1 13
=GR001 =GR001 =GR001 =GR001 +LC01
C -A200 C
+F04-F018 14
-F019 14
-F020 14
-F021 14 /65.4 F2
-S001 14
=GR001/51.5 =GR001/51.6 =GR001/51.7 =GR001/51.8
+LC01-X4 10 12
D -4097 D
/96.5
H05VV5-F
5x1,5 1 3
-X10 211 212 213 214 215 216 217 218 219 220
E E
F F
+F04-A09
/70.3
-X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 1M
Rack 0
I21.0 I21.1 I21.2 I21.3 I21.4 I21.5 I21.6 I21.7 X1/20/1M
Slot 9 X1/12/IX+1.0 X1/13/IX+1.1 X1/14/IX+1.2 X1/15/IX+1.3 X1/16/IX+1.4 X1/17/IX+1.5 X1/18/IX+1.6 X1/19/IX+1.7 /70.3
/70.3 /70.3 /70.3 /70.3 /70.3 /70.3 /70.3 /70.3
=GR001-F018:14 =GR001-F019:14 =GR001-F020:14 =GR001-F021:14 -A200:F2 +LC01-S001:14 +LC01-X4:12 -X10:218
G G
LCB SPARE LCB SPARE LCB SPARE LCB SPARE SCALANCE X204-2 FAULT RESET FAULTS SPARE SPARE
95 97
Date 13.10.2011 2.2040 00EAD03 EH001
DIGITAL INPUT BYTE 21 DIGITAL Stacker
Ed. by cw-de INPUT BYTE 19 CHECKBACK SIGNAL + F04
Appr. VUNG ANG LCB'S DI Page 96
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
96.9 98.0
F012_24V F012_24V
A
96.9 98.0 A
F012_0V F012_0V
-X10 221+ 221- 222+ 222- 223+ 223- 224+ 224- 225+ 225- 226+ 226- 227+ 227- 228+ 228- 229+ 229- 230+ 230-
B B
C C
D D
-X10 221 222 223 224 225 226 227 228 229 230
E E
F F
+F04-A09
/70.3
-X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1
Rack 0
I22.0 I22.1 I22.2 I22.3 I22.4 I22.5 I22.6 I22.7
Slot 9 X1/22/IX+2.0 X1/23/IX+2.1 X1/24/IX+2.2 X1/25/IX+2.3 X1/26/IX+2.4 X1/27/IX+2.5 X1/28/IX+2.6 X1/29/IX+2.7
/70.6 /70.6 /70.6 /70.6 /70.6 /70.6 /70.6 /70.6
-X10:221 -X10:222 -X10:223 -X10:224 -X10:225 -X10:226 -X10:227 -X10:228
G G
SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE
96 98
Date 13.10.2011 2.2040 00EAD03 EH001
DIGITAL INPUT BYTE 22 SPARE Stacker
Ed. by cw-de + F04
Appr. VUNG ANG Page 97
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
97.9
F012_24V
A
97.9 A
F012_0V
-X10 231+ 231- 232+ 232- 233+ 233- 234+ 234- 235+ 235- 236+ 236- 237+ 237- 238+ 238- 239+ 239- 240+ 240-
62.4 / UPS+4
B B
+F02-7-X4 10
22 24
C +F02-7-K100 C
/62.5 21
+F02-7-X4 11
D D
-X10 231 232 233 234 235 236 237 238 239 240
E E
F F
+F04-A09
/70.3
-X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 2M
Rack 0
I23.0 I23.1 I23.2 I23.3 I23.4 I23.5 I23.6 I23.7 /70.6
Slot 9 X1/32/IX+3.0 X1/33/IX+3.1 X1/34/IX+3.2 X1/35/IX+3.3 X1/36/IX+3.4 X1/37/IX+3.5 X1/38/IX+3.6 X1/39/IX+3.7 X1/40/2M
/70.6 /70.6 /70.6 /70.6 /70.6 /70.6 /70.6 /70.6
-X10:231 -X10:232 -X10:233 -X10:234 -X10:235 -X10:236 -X10:237 +F02-7-K100:21
G G
SPARE SPARE SPARE SPARE SPARE SPARE SPARE POWER BREAKDOWN
PLC, SCALANCE AND
PANEL PC ON UPS
97 99
Date 13.10.2011 2.2040 00EAD03 EH001
DIGITAL INPUT BYTE 23 SPARE Stacker
Ed. by cw-de POWER BRAKE DOWN + F04
Appr. VUNG ANG Page 98
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
=GR001/50.8
F0131_24V
A A
I+ I- I+ I- I+ I-
B B
C C
D D
MANA / 100.0
E E
-X11 1 2 3 PE 4 5 PE 6 7 PE 8 9 PE 10
PE PE PE PE
F F
+F04-A12
/72.0
-X1 L+ -X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1
Rack 1
X1/1/L+ IW256 IW257 IW258 IW259 IW260 IW261 IW262 IW263 COMP+
Slot 2 /72.2 X1/2/IWX/M0+_M0+ X1/3/IWX/M0-_M0- X1/4/IWX+2/M1+_IC0+ X1/5/IWX+2/M1-_IC0- X1/6/IWX+4/M2+_M1+ X1/7/IWX+4/M2-_M1- X1/8/IWX+6/M3+_IC1+ X1/9/IWX+6/M3-_IC1- X1/10/COMP+_n.c.
/72.2 /72.2 /72.2 /72.2 /72.2 /72.2 /72.2 /72.2 /72.2
=CG003+X-B01:I+ =CG003+X-B01:I- =CG004+X-B02:I+ =CG004+X-B02:I- =CG005+X-B03:I+ =CG005+X-B03:I- -X11:8 -X11:9
G G
BOOM PILE COLLISION 1 BOOM PILE COLLISION 2 PILE DISTANCE BOOM SPARE
(2 WIRE 4-20mA) (2 WIRE 4-20mA) LUFFING
98 100
Date 13.10.2011 2.2040 00EAD03 EH001
ANALOG INPUTS IW 256-263 Stacker
Ed. by cw-de + F04
Appr. VUNG ANG Page 99
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
=GR001/50.8 / F0131_0V
A A
B B
C C
D D
99.9 / MANA
E E
-X11 11 12 13 PE 14 15 PE 16 17 PE 18 19 PE 20
PE PE PE PE
F F
+F04-A12
/72.0
-X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 M
Rack 1
COMP- IW264 IW265 IW266 IW267 IW268 IW269 IW270 IW271 X1/20/M
Slot 2 X1/11/COMP-_Mana X1/12/IWX+8/M4+_M2+ X1/13/IWX+8/M4-_M2- X1/14/IWX+10/M5+_IC2+ X1/15/IWX+10/M5-_IC2- X1/16/IWX+12/M6+_M3+ X1/17/IWX+12/M6-_M3- X1/18/IWX+14/M7+_IC3+ X1/19/IWX+14/M7-_IC3- /72.2
/72.2 /72.2 /72.2 /72.2 /72.2 /72.2 /72.2 /72.2 /72.2
=CP001+GY-B001:5 -A12:11 =CP002+GY-B002:5 -A12:13 =CP003+GY-B003:5 -A12:15 =CL121+GY-B004:5 -A12:17
G G
PRESSURE SWITCH PRESSURE SWITCH PRESSURE SWITCH LEVEL CONTROLLER
BOOM LUFFING BOOM LUFFING BOOM LUFFING BOOM LUFFING
HYDRAULICS POS 2.105 HYDRAULICS POS 2.109 HYDRAULICS POS 3.18 HYDRAULICS POS 3.18
99 101
Date 13.10.2011 2.2040 00EAD03 EH001
ANALOG INPUTS IW 264-271 Stacker
Ed. by cw-de + F04
Appr. VUNG ANG Page 100
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
A A
BOOM LUFFING
MAIN CONTACTOR BOOM CONVEYOR TRAVEL DRIVE RAIL CLAMP 1 RAIL CLAMP 2 CABLE DRUM
BOOM CONVEYOR HYDRAULICS
BOMM CONVEYOR STANDSTILL MAIN CONTACTOR MAIN CONTACTOR MAIN CONTACTOR MAIN CONTACTOR
BRAKE OPEN MAIN CONTACTOR
ON HEATER ON ON ON ON ON
ON
Rack 0
Slot 10 /73.3 /73.3 /73.3 /73.3 /73.3 /73.3 /73.3 /73.3
/73.3 X1/2/QX.0 X1/3/QX.1 X1/4/QX.2 X1/5/QX.3 X1/6/QX.4 X1/7/QX.5 X1/8/QX.6 X1/9/QX.7 /73.3
X1/1/1L+ Q0.0 Q0.1 Q0.2 Q0.3 Q0.4 Q0.5 Q0.6 Q0.7 X1/10/1M
B B
-X1 1L+ -X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 1M
-X20 17 1 2 3 4 5 6 7 8 18
==00EAC03
C =AF001 =AE001+F01 C
+F01-5-X20 1 3 +F01-2-X20 1
F014_24V F014_24V
=GR001/51.0 102.0
D D
A1 A1 A1 A1 =AE002 A1 =AP010 A1 =AP020 A1 =AE004 A1
+F01-5 +F04 +F01-5
+F01-2-K003 +F04 +F04 +F04 +F04
-K000 -K001 -K002
A2 A2 A2 A2 -K004 A2 -K005 A2 -K006 A2 -K007 A2
E E
+F01-5-X20 2 4 +F01-2-X20 2
==00EAC03=AF001+F02/139.1
==00EAC03=AF001+F01/137.1
=AE001+F01/21.5
=AE002+F02/29.1
=AE004+F02/44.1
=AP010+F02/38.1
=AP020+F02/41.1
14 14 14 14 14
14 14 14 12 11 12 11 12 11 12 11 12 11
12 11 12 11 12 11
G G
100 102
Date 13.10.2011 2.2040 00EAD03 EH001
DIGITAL OUTPUT BYTE 0 Stacker
Ed. by cw-de + F04
Appr. VUNG ANG Page 101
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Rack 0
Slot 10 /73.3 /73.3 /73.3 /73.3 /73.3 /73.3 /73.3 /73.3
/73.3 X1/12/QX+1.0 X1/13/QX+1.1 X1/14/QX+1.2 X1/15/QX+1.3 X1/16/QX+1.4 X1/17/QX+1.5 X1/18/QX+1.6 X1/19/QX+1.7 /73.3
X1/11/2L+ Q1.0 Q1.1 Q1.2 Q1.3 Q1.4 Q1.5 Q1.6 Q1.7 X1/20/2M
B B
-X1 2L+ -X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 2M
-X20 35 19 20 21 22 23 24 25 26 36
C C
F014_24V F014_24V
101.1 103.0
D D
A1 A1 A1 A1 A1 A1 A1 A1
-K010 -K011 -K012 -K013 -K014 -K015 -K016 -K017
A2 A2 A2 A2 5 A/DC 24VDC A2 5 A/DC 24VDC A2 5 A/DC 24VDC A2 5 A/DC 24VDC A2
Optocoupler Optocoupler Optocoupler Optocoupler
E E
22 21 /82.7
G G
101 103
Date 13.10.2011 2.2040 00EAD03 EH001
DIGITAL OUTPUT BYTE 1 Stacker
Ed. by cw-de + F04
Appr. VUNG ANG Page 102
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Rack 0
Slot 10 /73.6 /73.6 /73.6 /73.6 /73.6 /73.6 /73.6 /73.6
/73.6 X1/22/QX+2.0 X1/23/QX+2.1 X1/24/QX+2.2 X1/25/QX+2.3 X1/26/QX+2.4 X1/27/QX+2.5 X1/28/QX+2.6 X1/29/QX+2.7 /73.6
X1/21/3L+ Q2.0 Q2.1 Q2.2 Q2.3 Q2.4 Q2.5 Q2.6 Q2.7 X1/30/3M
B B
-X1 3L+ -X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 3M
-X20 53 37 38 39 40 41 42 43 44 54
C C
F014_24V F014_24V
102.1 104.0
D D
A1 A1 A1 A1 A1 A1 A1 A1
-K020 -K021 -K022 -K023 -K024 -K025 -K026 -K027
5 A/DC 24VDC A2 5 A/DC 24VDC A2 5 A/DC 24VDC A2 5 A/DC 24VDC A2 5 A/DC 24VDC A2 5 A/DC 24VDC A2 5 A/DC 24VDC A2 5 A/DC 24VDC A2
Optocoupler Optocoupler Optocoupler Optocoupler Optocoupler Optocoupler Optocoupler Optocoupler
E E
G G
102 104
Date 13.10.2011 2.2040 00EAD03 EH001
DIGITAL OUTPUT BYTE 2 Stacker
Ed. by cw-de + F04
Appr. VUNG ANG Page 103
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
A A
E-HOUSE AIR RAIL CLAMP 1 RAIL CLAMP 2
EXTERNAL WARNING
FLOODLIGHT ON CONDITION SOLENOID VALVE SOLENOID VALVE WARNING LIGHT SPARE RELAY
LIGHTING ON SOUNDER
REMOTE ON/OFF COIL CLAMP OPEN COIL CLAMP OPEN
Rack 0
Slot 10 /73.6 /73.6 /73.6 /73.6 /73.6 /73.6 /73.6 /73.6
/73.6 X1/32/QX+3.0 X1/33/QX+3.1 X1/34/QX+3.2 X1/35/QX+3.3 X1/36/QX+3.4 X1/37/QX+3.5 X1/38/QX+3.6 X1/39/QX+3.7 /73.6
X1/31/4L+ Q3.0 Q3.1 Q3.2 Q3.3 Q3.4 Q3.5 Q3.6 Q3.7 X1/40/4M
B B
-X1 4L+ -X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 -X1 4M
-X20 71 55 56 57 58 59 60 61 62 72
C =GP001+F02 C
-X4 3 5
+F02-7-X20 1 3
-4101
/104.5 12 14
H05VV5-F
F014_24V 15 m -K037
5x1,5 1 2 /104.7
103.1 11
D -X4 4 D
+X 1 5
-P001
A1 A1 A1 A1 A1 WARNING x1 x3 A1
INDICATION
+F02-7-K030 +F02-7-K031 -K032 -K033 -K034 -K037
A2 A2 A2 5 A/DC 24VDC A2 5 A/DC 24VDC A2 x2 x4 A2
Optocoupler Optocoupler
2 6
E E
+F02-7-X20 2 4
-4101
/104.5 3 4
103.9 -X20 63 64 65 66 67 68 69 70
F014_0V
F F
14 14 14 13 14 =AP010/39.5 13 14 =AP020/42.5 14
G G
103 105
Date 13.10.2011 2.2040 00EAD03 EH001
DIGITAL OUTPUT BYTE 3 Stacker
Ed. by cw-de + F04
Appr. VUNG ANG Page 104
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
A A
RATED VALUE
PROPORTIONLA SPARE
VALVE AMPLIFIER
Rack 1
Slot 3 /74.1 /74.1 /74.1 /74.1 /74.1 /74.1
/74.1 X1/3/QWX/QI0_QV0 X1/4/QWX/n.c._S0+ X1/5/QWX/n.c._S0- /74.1 X1/7/QWX+2/QI1_QV1 X1/8/QWX+2/n.c._S1+ X1/9/QWX+2/n.c._S1- /74.1 /74.1
X1/1/L+ QW256 QWX QW257 X1/6/Mana0 QW258 QWX+2 QW259 X1/10/Mana1 X1/20/M
B B
-X1 L+ -X1 -X1 -X1 -X1 Mana0 -X1 -X1 -X1 -X1 Mana1 -X1 M
-X21 1 2 3 4 5 6 7 8 9 10
F015_24V
=GR001/51.1
C C
U1+10V U1-10V
=AE002/31.7 =AE002/31.7
D D
E E
=GR001/51.2
F015_0V
F F
G G
104 =CH102+/106
Date 13.10.2011 2.2040 00EAD03 EH001
ANALOG OUTPUT 256-259 Stacker
Ed. by cw-de + F04
Appr. VUNG ANG Page 105
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
=GR001+F04/49.3
F001_24V
A Y22 / 108.0 A
Y12 / 108.0 13
+F03-A001
/106.4 14
DC 24V DC 24V
+F03-A001 +F03-A002
B
24...240V UC A1 63 Y22 Y12 T3 1 13 23 33 43 51 AC/DC 24V A1 13 23 33 43 51 B
8
7
6
63 13 23 33 43 51 13 23 33 43 51
SIEMENS =EH001+F04/93.7
5
4 /106.6
==00EAC03=AF0 ==00EAC03=AF0 =AE001+F01/26. SIEMENS =AE002+F02/29.1=AE004+F02/44.1=GR002+F02/20.0=GR002+F02/20.1
01+F01/136.7 01+F02/139.1 4
3TK2826-1CW30 64
3
14 24 34 44 52 3TK2830-1CB30 14 24 34 44 52
2
1
OFF
ON
A2 64 T2 Y34 T1 Y33 14 24 34 44 52 A2 14 24 34 44 52
0V 0V
C C
Y33_1
107.0
=EH001 12 14
+F04
-K010 11
=EH001+F04/102.1
D D
E E
107.0
Y33_2
F F
T1 / 109.9
=GR001+F04/49.4 T2 / 109.9
F001_0V
G G
=EH001+F04/105 107
Date 13.10.2011 2.2040 00EAD03 CH102
EMERGENCY STOP CIRCUIT Stacker
Ed. by cw-de E-STOP RELAY +
Appr. VUNG ANG Page 106
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
106.2 / Y33_1
+F03-X3 1 4
A A
21
-X4 12
+F01-5-Q003
==00EAC03=AF001+F01/136.7 22
21
-Q003
+F01-5-X3 2 =AE002+F02/28.6 22
B B
+F01-5-X3 3
-X4
21 11
+F02-Q006
==00EAC03=AF001+F02/138.6 22 -X1 11
+F01-5-X3 4
C
+F03-X3 7
C
+F03-X3 2 =AP010
+F02 -X1 12
-X4 12
21
D
-Q003 D
=AP010+F02/37.6 22
-X4
11
-X1 11
+F03-X3 3
E E
=AE004 +F03-X3 8
+F02 -X1 12
=AP020
-X4 12 +F02 -X1 12
-X4 12
21
-Q003
=AE004+F02/43.6 22
21
F F
-Q003
=AP020+F02/40.6 22
-X4
11
-X4
-X1 11 11
-X1 11
G G
+F03-X3 9
106.2 / Y33_2
106 108
Date 13.10.2011 2.2040 00EAD03 CH102
EMERGENCY STOP CIRCUIT Stacker
Ed. by cw-de E-STOP RELAY +
Appr. VUNG ANG Page 107
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
A 106.5 / Y12 A
106.5 / Y22
B B
C C
D D
T2 / 109.0
T1 / 109.0
E E
+F03-X3 10 5 6 11 12 13 14 15 16 17 18 19 20 21 22 23
-4059 -4060 -4061 -4062
=EH001+F04/93.1 =EH001+F04/93.2 =EH001+F04/93.3 =EH001+F04/93.4
=EH001+F04/93.1 =EH001+F04/93.2 =EH001+F04/93.3 =EH001+F04/93.4
H05VV5-F H05VV5-F H05VV5-F H05VV5-F
30 m 25 m 15 m 45 m
7x1,5 3 4 5 6 7x1,5 3 4 5 6 7x1,5 3 4 5 6 7x1,5 3 4 5 6
F F
11 21 13 11 21 13 11 21 13 11 21 13
+X =CH112+X =CH113+X =CH114+X
-S001 12 22 14
-S002 12 22 14
-S003 12 22 14
-S004 12 22 14
Emergency Emergency Emergency Emergency
stop stop stop stop
=EH001+F04/93.1
=EH001+F04/93.2
=EH001+F04/93.3
=EH001+F04/93.4
G E-STOP 1 E-STOP 2 E-STOP 3 E-STOP 4 G
PLACED ON LADDER TO STAIRS TO LADDER
BOOM CONVEYOR HYDRAULICS E-HOUSE TO TRIPPERCAR
107 109
Date 13.10.2011 2.2040 00EAD03 CH102
EMERGENCY STOP CIRCUIT Stacker
Ed. by cw-de EXTERNAL E-STOP BUTTONS +
Appr. VUNG ANG Page 108
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
A T2 / 106.5 A
T1 / 106.5
B B
C C
D D
108.9 / T2
108.9 / T1
E E
+LC01-X3 1 2 3 4
F F
11 21 13 11 21 13 11 21 13 11 21 13 11 21 13
=CH115+X =CH122+X =CH122+X ==00EAC03 ==00EAC03
=CH111 =CH112
-S005 12 22 14
-S006 12 22 14
-S007 12 22 14
+X-S001
22 14
+X-S002
22 14
12 12
Emergency Emergency Emergency
stop stop stop
=EH001+F04/93.5
=EH001+F04/93.6
=EH001+F04/93.7
=EH001+F04/77.2
=EH001+F04/77.3
G E-STOP 5 E-STOP 6 E-STOP 7 BOOM CONVEYOR BOOM CONVEYOR G
MIDWAY PLACED ON E-HOUSE PULL CORD SWITCH PULL CORD SWITCH
TRIPPER CAR HYDRAULICS OPERATOR DESK LEFT SIDE RIGHT SIDE
108 =CBL/110
Date 13.10.2011 2.2040 00EAD03 CH102
EMERGENCY STOP CIRCUIT Stacker
Ed. by cw-de EXTERNAL E-STOP BUTTONS +
Appr. VUNG ANG Page 109
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
A 3640 B
A A
700
1000 1000
B B
2300
2936 1940
2852
390 800
550
478
C C
348 1110
179
1008
2000
3900
C-C
E-E
D D
154 1000 1000 800 800
600 23
y 23
XXXXXXX XXXXXXX XXXXXXX
XXXXXXX
XXXXXXX
E E
2490
2276
2200
23 25
400
770
XXXXXXX
XXXXXXX
Operator
Panel
990
25
1766 600 TRAFO
540
50 kVA
960
24 +LC01 ==00EAD03=GU001-T001 24
XXXXXXX XXXXXXX
24
F YORK YT8 F
478
18 40
300
XXXXXXX = 60mm Isolation
1090
3600 40
80
80
600
G G
2600 2800
=CH102/109 111
Date 13.10.2011 2.2040 00EAD03 CBL
E-House Stacker
Ed. by cw-de +
Appr. VUNG ANG Page 110
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
3640
A B
A A
1190
600
900 192
900
700
1000 1000
B B
390
2936 2300
2852
800 1110
550 478
C C
348
179
2000 1008
C-C
XXXXXXX
XXXXXXX
154
y
E 2474 E
2276 2200 1765 400
770
XXXXXXX
XXXXXXX
Operator
Panel
990
TRANSFORMER
50 kVA 540
600
==00EAD03=GU001-T001
960
+LC01
24
24
XXXXXXX XXXXXXX
18 478
F F
40
XXXXXXX = 60mm Isolation
300
1110
XXXXXXX XXXXXXX YORK YT8
3600
80
600
G G
2600 2800 40
110 +F01/112
Date 13.10.2011 2.2040 00EAD03 CBL
E-House EAD04 Stacker
Ed. by cw-de +
Appr. VUNG ANG Page 111
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
D D
E E
F F
G G
+/111 113
Date 13.10.2011 2.2040 00EAD03 CBL
Enclosure legend Stacker
Ed. by cw-de ==00EAD03=CBL+F01-2 + F01
Appr. VUNG ANG Page 112
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
B B
C C
D D
E E
F F
G G
112 114
Date 13.10.2011 2.2040 00EAD03 CBL
Enclosure legend Stacker
Ed. by cw-de ==00EAD03=CBL+F01-3 + F01
Appr. VUNG ANG Page 113
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
B B
C C
D D
E E
F F
G G
113 115
Date 13.10.2011 2.2040 00EAD03 CBL
Enclosure legend Stacker
Ed. by cw-de ==00EAD03=CBL+F01-4 + F01
Appr. VUNG ANG Page 114
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
D D
E E
F F
G G
114 116
Date 13.10.2011 2.2040 00EAD03 CBL
Enclosure legend Stacker
Ed. by cw-de ==00EAD03=CBL+F01-5 + F01
Appr. VUNG ANG Page 115
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
C C
D D
E E
F F
G G
115 117
Date 13.10.2011 2.2040 00EAD03 CBL
Enclosure legend Stacker
Ed. by cw-de ==00EAD03=CBL+F01-6 + F01
Appr. VUNG ANG Page 116
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
A A
IP54 RW IP54 RW
MG
MG MGF
MODAN MODAN KH
==00EAC03 + ==00EAD03 +
=AF001 0 =AE002 0
2200
D .1 D
.H18
SL-Einbau .1
obere .H19
Reihe .1
.H20
.1 +F01-4 IP54
.H21
.1
.H22
.1
.H23
.1
.H24
.1
.H25
E .1 E
.H26
.1 690V Bereich
.H27
.1
.H28
3 .1
.H29 +F01-5 IP54
.1
.H30
.1
.H31
.1
.H32
SL-Einbau .1
untere .H33
F .1 F
Reihe .H34
.1
.H35
.1 +F01-6 IP54
.H36 +F02-7
+F01 +F02
1000 1000
G G
116 118
Date 13.10.2011 2.2040 00EAD03 CBL
CABINET LAYOUT OVERVIEW +F01 Stacker
Ed. by cw-de & +F02 + F01
Appr. VUNG ANG Page 117
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
A A
TW IP54 RW TW IP54 RW
MODAN KH MODAN KH
B B
C C
D D
2200
E E
F F
+F03 +F04
G 800 800 G
117 119
Date 13.10.2011 2.2040 00EAD03 CBL
CABINET LAYOUT OVERVIEW +F03 Stacker
Ed. by cw-de & +F04 + F01
Appr. VUNG ANG Page 118
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
MG
A A
MG
MODAN MODAN
.H01
.1
.H02
.1
.H03
1 .1 +F01-2 =AE001+F01-2-X20
.H04
10
9
8
B B
.1
.H05 =AE001+F01-2-X10
.1
=AE001+F01-2-X9
.H06 1
+F02-7
7
5
6
.1
=AE001+F01-2-X3
.H07
.1 3 4 2
.H08
.1 =AE001+F01-2-X1 45 49 54
.H09
.1
.H10 +F01-3 =GU001+F01-4-X10
.1
.H11
.1
72
71
11
68
50
57
60
44
C .H12 C
.1 59 66
.H13 =GU001+F01-4-X1 =AE004+F02-7-X9
.1 =AP020+F02-7-X9
.H14
.1 =AP010+F02-7-X9
.H15
.1
67
48
53
65
52
47
46
73
74
51
56
55
62
61
64
63
70
69
.H16 =AE004+F02-7-X2
.1
.H17 +F01-4 =GQ001+F02-7-X1
=GU001+F01-4-X10
2200
.1
.H18
SL-Einbau .1 12
obere .H19
Reihe .1
=GU001+F01-4-X1
.H20
25
27
26
29
28
31
30
33
32
35
34
36
D =GR002+F02-7-X4 D
.1
.H21 24 23
.1 +F01-5
25
.H22 ==00EAC03=AF001+F01-5-X20
.1
.H23
.1 21 ==00EAC03=AF001+F01-5-X10
=GU002+F01-6-X1
.H24
40
38
39
.1 ==00EAC03=AF001+F01-5-X9 =GR001+F02-7-X1
.H25 137 ==00EAC03=AF001+F01-5-X5
.1
==00EAC03=AF001+F01-5-X3 1 2 3 198 199
23
22
.H26
139
138
=GP001+F02-7-X1
19
27
28
24
26
.1
.H27
.1 20 =GP001+F02-7-X2
E .H28 ==00EAC03=AF001+F01-5-X1
E
3
16
15
17
18
19
20
21
22
41
37
=GP001+F02-7-X20
5
7
6
4
.1
.H29
.1 =AH001+F02-7-X1
.H30 +F01-6 =GS001+F01-6-X10
.1
.H31
.1 17 =AH002+F02-7-X2
.H32 14 15 =GU002+F01-6-X1
SL-Einbau .1 13
42
43
.H33 16
14
8
9
untere =AH003+F02-7-X2
.1
Reihe .H34 10 13 1112
.1
=EH001+F02-7-X4
.H35 =GS001+F01-6-X1
.1
F .H36 F
+01
1000 1000
G G
118 120
Date 13.10.2011 2.2040 00EAD03 CBL
INTERNAL CABINET LAYOUT Stacker
Ed. by cw-de + F01
Appr. VUNG ANG Page 119
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
60 330 40 190 60
A A
45
200
200
60 559 560 561 562 563 564 565 566 567 568 569 570 572 44
60
B B
11
10
13
12
15
14
17
16
19
18
21
20
23
22
25
24
27
26
29
28
31
30
33
32
35
34
37
36
39
38
41
40
43
42
3
2
5
4
7
6
9
8
2
3
4
5
6
7
8
140
140
60
60
573
66
67
68
69
70
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
140
571 1
310
==00EAD03
60
=EH001
+F04-X21
C 99 C
890
==00EAC51
=CL101
+F04-X7
60
==00EAD03=EH001+F04-X10
2200
310 ==00EAD03
=AE002
+F04
-X4
D ==00EAD03
D
=AP010
+F04-X4
60
1130
==00EAD03
=EH001
107
101
102
103
104
+F04-X11
180
1 105106
==00EAD03
=AP020
60
+F04-X4
==00EAD03=EH001+F04-X20
==00EAD03=EH001+F04-X10
==00EAD03
=CH102
E +F03-X3 ==00EAC51 E
120
=CL101
+F04-X4
==00EAD03
=AE001
+F04
-X4
80
100
100
100
F F
C-Profil
Auf Trägerschienen
am Boden montiert
G 60 560 60 60 150 60 150 60 140 60 G
119 +F02/121
Date 13.10.2011 2.2040 00EAD03 CBL
INTERNAL CABINET LAYOUT Stacker
Ed. by cw-de + F01
Appr. VUNG ANG Page 120
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
+F01/120 122
Date 13.10.2011 2.2040 00EAD03 CBL
Enclosure legend Stacker
Ed. by cw-de ==00EAD03=CBL+F02-7 + F02
Appr. VUNG ANG Page 121
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
G G
121 +F03/123
Date 13.10.2011 2.2040 00EAD03 CBL
Enclosure legend Stacker
Ed. by cw-de ==00EAD03=CBL+F02-7 + F02
Appr. VUNG ANG Page 122
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
E E
F F
G G
+F02/122 +F04/124
Date 13.10.2011 2.2040 00EAD03 CBL
Enclosure legend Stacker
Ed. by cw-de ==00EAD03=CBL+F03 + F03
Appr. VUNG ANG Page 123
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
+F03/123 125
Date 13.10.2011 2.2040 00EAD03 CBL
Enclosure legend Stacker
Ed. by cw-de ==00EAD03=CBL+F04 + F04
Appr. VUNG ANG Page 124
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
G G
124 +A008/126
Date 13.10.2011 2.2040 00EAD03 CBL
Enclosure legend Stacker
Ed. by cw-de ==00EAD03=CBL+F04 + F04
Appr. VUNG ANG Page 125
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
C C
D D
E E
F F
G G
+F04/125 127
Date 13.10.2011 2.2040 00EAD03 CBL
Enclosure legend Stacker
Ed. by cw-de ==00EAD03=CBL+A008 + A008
Appr. VUNG ANG Page 126
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
A A
+A008
+A008
60
B B
10
11
220
6 9 8 7
C C
100
=GS001-X4
D D
1000
==00EAD03=GS001-X1
350
PE
E E
+A008
100
CONNECTOR GLAND
F F
MS-M 63 x 1,5 MS-M 63 x 1,5 M20 M20
100
600 539
2 xSKINTOP MS-M 63 x 1,5
G LAPP.53112070 G
126 +A009/128
Date 13.10.2011 2.2040 00EAD03 CBL
POWER TERMINAL BOX MAIN Stacker
Ed. by cw-de FEEDING + A008
Appr. VUNG ANG Page 127
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
B B
C C
D D
E E
F F
G G
+A008/127 129
Date 13.10.2011 2.2040 00EAD03 CBL
Enclosure legend Stacker
Ed. by cw-de ==00EAD03=CBL+A009 + A009
Appr. VUNG ANG Page 128
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
A A
B B
+A009
+A009
C C
35
60
160
380
D D
==00EAD03=AE002+A009-X4
60
40
60 430 60
E 600 E
+A009
dummy
F plug F
G G
128 +A010/130
Date 13.10.2011 2.2040 00EAD03 CBL
TERMINAL BOX BOOM LUFFING Stacker
Ed. by cw-de + A009
Appr. VUNG ANG Page 129
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
D D
E E
F F
G G
+A009/129 131
Date 13.10.2011 2.2040 00EAD03 CBL
Enclosure legend Stacker
Ed. by cw-de ==00EAD03=CBL+A010 + A010
Appr. VUNG ANG Page 130
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
A A
+A010
+A010
40
60
B B
3
160
==00EAD03 ==00EAD03
=AE001 =AE001
-X5 -X10
600
C C
60
==00EAD03 ==00EAD03
=EH001 =AE001
-X10 -X6
150
==00EAD03
=AE001
D -X1 D
60
40
549
600
+A010
E E
dummy dummy
plug plug
dummy
plug
F F
600
G G
130 +LC01/132
Date 13.10.2011 2.2040 00EAD03 CBL
JUNCTION BOX TRAVEL DRIVE Stacker
Ed. by cw-de + A010
Appr. VUNG ANG Page 131
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
C C
D D
E E
F F
G G
+A010/131 133
Date 13.10.2011 2.2040 00EAD03 CBL
Enclosure legend ==CBL=CBL+LC01 Stacker
Ed. by cw-de + LC01
Appr. VUNG ANG Page 132
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
A A
B B
597 480 480
544
498
20° 498 20°
447
447
148.5
60
60
C C
960
960
675
675
790
790
557
630
630
557
D 358-368 358-368 D
148.5
72
140
140
47
47
70
70
33
33
E 50 50 270 270 50 E
500
1.5 1.5 370 370
524 400 400
600
AP 2666.600
F F
G G
132 134
Date 13.10.2011 2.2040 00EAD03 CBL
OVERVIEW OPERATOR PANEL Stacker
Ed. by cw-de + LC01
Appr. VUNG ANG Page 133
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
A A
40
B B
==CBL+LC01
43
C C
==00EAD03=GU002-T001
EMB.DTSspG7,5
DTSspG7,5
1
780
D D
60
==00EAD03 ==00EAD03 ==00EAD03 ==00EAD03 ==00EAD03
=GU002 =AE001 =EH001 =CH102 =AH003
-X1 -X3 -X4 -X3 -X2
E E
100
60
60
F F
530
G G
133 135
Date 13.10.2011 2.2040 00EAD03 CBL
INSTALLATION PLATE OPERATOR Stacker
Ed. by cw-de PANEL + LC01
Appr. VUNG ANG Page 134
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
A A
+LC01
50
KEY-
SWITCH
B
==00EAD03 1 TRAVEL DRIVE B
=AE001-S001
386,6 ULTIMATE LIMIT BYPASS
KEY SWITCH
==00EAD03=AE001-S001
1
PUSH
BUTTON RESET
100
==00EAD03=EH001-S001
BLACK
C C
PANEL PC 2 RESET
285,6
310
==00EAD03=EH001-S001
2
498
D D
200
EMERGENCY STOP
==00EAD03
=CH122+X-S007
3 EMERGENCY STOP
==00EAD03=CH122+X-S007
E 5 E
100
F 50 410 68 69 F
G G
134 ==00EAC03=AF001+F01/136
Date 13.10.2011 2.2040 00EAD03 CBL
LID/ROOF OPERATOR PANEL Stacker
Ed. by cw-de + LC01
Appr. VUNG ANG Page 135
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
==00EAD03=GS001/16.8 / L1L690
TN-S 690V
L1L690 / ==00EAD03=GU001/18.1
==00EAD03=GS001/16.8 / L2L690 L2L690 / ==00EAD03=GU001/18.1
A ==00EAD03=GS001/16.8 / L3L690 L3L690 / ==00EAD03=GU001/18.1 A
+F01-5-K100
+F01-5-Q001 1 3 5 13 21
PR222MP
40-100A -PE +F01-5-Q002
(77A) 1 3 5 -X3:7 1-1,6 A 14 22
==00EAD03=EH001+F04/75.2 (1,22)
==00EAD03=EH001+F04/75.5
-X3:8 97 95 I> I> I>
B
2 4 6 B
I> I> I> X4:6 7
98 96
2 4 6
-X4:7 9
==00EAD03=EH001+F04/75.4
/136.7
-PE
-X4:8 8
-X4:3 4
1 2
+F01-5-T002 +F01-5-XT001
0,8kVA
690V 3 4 +F01-5-X9 1
110V
137.0 / 110VL
=CH102 1
C
1 13 21
-X3 C
==00EAD03 23
1 3 5 +F01-5-F001 =CH102
+F01-5-Q003 C 4A 2 14 22
+F03-A001 24
==00EAD03=EH001+F04/75.6
/136.7 2 4 6
==00EAD03=CH102+/106.4
=CH102 2
-X3
+F01-5-X9 2
D D
+F01-5-B001 10
1 2
-T001
Measuring
current 1 4
10
transformers 2 6
alarm
11 12
E 11 12 E
12 14
-PE
+F01-5-K000
==00EAD03=EH001+F04/101.1 11
F +F01-5-X1 1 2 3 +F01-5-X5
PE 1 2 F
-1054
H07 RN-F
30 m 95
4x25 BN BK GY GNYE
+F01-5-K100
U V W 1 2 /136.1 /136.4 96
M 3 4 /136.1 A1 A1
+X-M001 3~ 5 6 /136.1
+F01-5-Q003 +F01-5-K003
/137.1 13 14 ==00EAD03=EH001+F04/75.7
75kW A2 A2
Θ
75kW 21 22 ==00EAD03=CH102+/107.2
PE
76,5A 31 32
G cosφ0,87 43 44 110VN / 137.0 G
14851/min 53 54
BOOM 61 62 MAIN CONTACTOR 14 EARTH FAULT
11 ==00EAD03=EH001+F04/75.7
12
==00EAD03=CBL+LC01/135 CONVEYOR 137
Date 13.10.2011 2.2040 00EAC03 AF001
BOOM CONVEYOR MOTOR 690V Stacker
Ed. by cw-de + F01
Appr. VUNG ANG Page 136
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
A A
136.5 / 110VL
136.9 / 110VN
B B
1 13 21
+F01-5-F002
C 4A 2 14 22
==00EAD03=EH001+F04/78.7
C C
12 14
+F01-5-K002
==00EAD03=EH001+F04/101.3 11
D D
-PE
E E
+F01-5-X9 3 PE 4
-1055
H07 RN-F
30 m
3x1.5 BN GNYE BU
1
PE
F +X-M001 F
/136.1
110V 2
109W
BOOM
CONVEYOR
STANDSTILL
HEATER
G G
136 +F02/138
Date 13.10.2011 2.2040 00EAC03 AF001
BOOM CONVEYOR STANDSTILL Stacker
Ed. by cw-de HEATER 110V AC + F01
Appr. VUNG ANG Page 137
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
==00EAD03=GR002/19.8 / L1L400
TN-S 400V
L1L400 / 139.1
==00EAD03=GR002/19.8 / L2L400 L2L400 / 139.1
A ==00EAD03=GR002/19.8 / L3L400 L3L400 / 139.1 A
==00EAD03=EH001+F04/76.1
I> I> I>
==00EAD03=EH001+F04/76.4 14
B
2 4 6 B
13 13
12 12
21
-Q006
==00EAD03=CH102+/107.2 22
11 11
C C
10 10
1 3 5
-Q006 9 9
/138.4 2 4 6
8 8
7 7
6 6
D D
5 5
4 4
13
-Q004
==00EAD03=EH001+F04/76.1 14
3 3
1 1,
E -Q006A1 / 139.1 E
2 2
A1
-Q006A2 / 139.2
-Q006 16 16
20kW A2
15 15
-X3 -PE
F 1 2 3 F
-1056
H07 RN-F -X1 U1 V1 W1 PE
30 m
BN BK GY GNYE
4x2.5 1 2 /138.1
3 4 /138.2
U V W 5 6 /138.2
13 14 ==00EAD03=EH001+F04/76.4
-M002
M 21 22 ==00EAD03=CH102+/107.2
0,16 kW
3~
400V PE
0,4A
G 50Hz IP56 G
BOOM CONVEYOR
BRAKE
+F01/137 139
Date 13.10.2011 2.2040 00EAC03 AF001
BOOM CONVEYOR BRAKE 400V Stacker
Ed. by cw-de MAIN CIRCUIT + F02
Appr. VUNG ANG Page 138
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
1 3 5 13 21
+F02-7-Q005
0,63-1,0 A 14 22
(0,84)
==00EAD03=EH001+F04/76.2
I> I> I>
B
2 4 6 B
-PE
1 2
+F02-7-T003 +F02-7-XT002
0,16kVA
400V 3 4
110V
1 13 21
C +F02-7-F002 C
C 1A 2 14 22
==00EAD03=EH001+F04/76.3
-X9 3 4
=CH102 3
-X3
D ==00EAD03 33 D
=CH102
+F03-A001 34
==00EAD03=CH102+/106.5
=CH102 4
-X3
E E
12 14
+F04-K001
==00EAD03=EH001+F04/101.2 11
138.8 / -Q006A1
138.8 / -Q006A2
F F
G G
138 ==00EAC51=CL101+/140
Date 13.10.2011 2.2040 00EAC03 AF001
BOOM CONVEYOR BRAKE 400V Stacker
Ed. by cw-de CONTROL CIRCUIT + F02
Appr. VUNG ANG Page 139
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
A A
B
+X-B001 B
C C
1 2 3 4 5 6 7 8
D D
-4001
H05VVC4V5-K
50 m
5x0.5 1 2 3 4
+F04-X7 1 2 3 4
E E
==00EAD03=EH001+F04/78.5 / B01_4
==00EAD03=EH001+F04/78.5 / B01_5
F F
==00EAC03=AF001+F02/139 +F04/141
Date 13.10.2011 2.2040 00EAC51 CL101
TRIPPER CAR CHUTE BLOCKED Stacker
Ed. by cw-de MONITORING +
Appr. VUNG ANG Page 140
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
==00EAD03=EH001/65.8 ==00EAD03=EH001/65.8
CH6 CH5
A A
-U001
B B
2 1
==00EAD03=EH001/78.7
C C
-X4 1 2 3 4 7 8
D D
-4068
==00EAD03=EH001/78.1
==00EAD03=EH001/78.1
H05VV5-F
30 m
5x1,5 3 4
+/140.8 / F016_24V
+/140.8 / F016_0V
==00EAC51 11 21 13
=CH121
E +X-S001 12 22 14 E
==00EAD03=EH001/78.1
-4069
==00EAD03=EH001/78.2
==00EAD03=EH001/78.2
H05VV5-F
30 m
5x1,5 3 4
F F
==00EAC51 11 21 13
=CH122
+X-S002 12 22 14
==00EAD03=EH001/78.2
G G
+/140 ==PARTLIST=+F01/142
Date 13.10.2011 2.2040 00EAC51 CL101
TRIPPER CAR PULL CORD SWITCH'S Stacker
Ed. by cw-de + F04
Appr. VUNG ANG Page 141
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Quantity
Device tag Designation Type Number Supplier
==00EAD03=GS001-A001 1 Socomec Diris A40 110 … 400 VAC /12...48VDC 48251201 SOCOMEC
==00EAD03=AE001-S001 2 ACTUATOR-/INDICATOR COMPONENT CONTACT BLOCK WITH 1 CONTACT ELEMENT SCREW TERMINAL, 1NO 3SB3400-0B SIEMENS
D D
E E
F F
G G
==00EAC51=CL101+F04/141 +F01-2/143
Date 13.10.2011 2.2040 PARTLIST
Parts list Stacker
Ed. by cw-de + F01
Appr. VUNG ANG Page 142
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Quantity
Device tag Designation Type Number Supplier
==00EAD03=AE001-Q001 1 T4 250 Fix (F) - 3 polig -lu (40°) 36kA/400V 1SDA054174R1 ABB
==00EAD03=AE001-Q001 1 Rotary handle operating mechanism RHE normal for fixed and plug-in T4 - T5 054929 ABB
==00EAD03=AE001-Q001 1 auxiliary contact AUX -C3Q 1SY 24V DC for T4-T5-T6 1SDA054915R1 ABB
C C
==00EAD03=AE001-Q002 1 MS116-1.0-HKF1-11 Manual Motor Starter MS116-1.0-HKF1-11 ABB
==00EAD03=AE001-Q003 1 Block Contactors A50-30-22 22 kW 400V 2NO/2NC coil voltage 110V AC A50-30-22 ABB
==00EAD03=AE001-Q003 1 Diode suppressor contactor choke RV 5/133 50...110 AC/DC RV 5/133 ABB
E E
F F
G G
+F01/142 +F01-3/144
Date 13.10.2011 2.2040 PARTLIST
Parts list Stacker
Ed. by cw-de + F01-2
Appr. VUNG ANG Page 143
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Quantity
Device tag Designation Type Number Supplier
C C
D D
E E
F F
G G
+F01-2/143 +F01-4/145
Date 13.10.2011 2.2040 PARTLIST
Parts list Stacker
Ed. by cw-de + F01-3
Appr. VUNG ANG Page 144
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Quantity
Device tag Designation Type Number Supplier
==00EAD03=GU001-Q001 1 T4 250 Fix (F) - 3 polig -lu (40°) 36kA/400V 1SDA054174R1 ABB
==00EAD03=GU001-Q001 1 Rotary handle operating mechanism RHE normal for fixed and plug-in T4 - T5 054929 ABB
==00EAD03=GU001-Q001 1 auxiliary contact AUX -C3Q 1SY 24V DC for T4-T5-T6 1SDA054915R1 ABB
B B
C C
D D
E E
F F
G G
+F01-3/144 +F01-5/146
Date 13.10.2011 2.2040 PARTLIST
Parts list Stacker
Ed. by cw-de + F01-4
Appr. VUNG ANG Page 145
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Quantity
Device tag Designation Type Number Supplier
==00EAC03=AF001-Q001 1 circuit breaker Tmax electrical release In 100A / 70kA T4L250R100 ABB
==00EAC03=AF001-Q001 1 Rotary handle operating mechanism RHE normal for fixed and plug-in T4 - T5 054929 ABB
==00EAC03=AF001-Q001 1 auxiliary contact AUX -C3Q 1SY 24V DC for T4-T5-T6 1SDA054915R1 ABB
==00EAC03=AF001-Q001 1 contact for status signal tripping solenoid breaker S51 AUX-SA 1 S51 T4 T5 ABB
D D
==00EAC03=AF001-Q002 1 motor circuit breaker MS325 1-1,6A 690V AC 1SAM150000R1006 ABB
==00EAC03=AF001-Q003 1 block contactor A145 110kW 690V 2NO/2NC coil voltage 110V AC A145-30-22 ABB
==00EAC03=AF001-Q003 1 Diode suppressor contactor choke RV 5/133 50...110 AC/DC RV 5/133 ABB
==00EAC03=AF001-XT001 1 Component terminal block, Connection method: Screw connection, Width: 8.2 mm, Mounting type: NS 35/7,5, NS 35/15, NS 32, Color: gray 0313085 Phoenix Contact
F F
G G
+F01-4/145 +F01-6/147
Date 13.10.2011 2.2040 PARTLIST
Parts list Stacker
Ed. by cw-de + F01-5
Appr. VUNG ANG Page 146
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Quantity
Device tag Designation Type Number Supplier
==00EAD03=GS001-Q000 1 T4 250 Fest (F) - 3 polig -lu (40°) 36kA/400V 1SDA054176R1 ABB
==00EAD03=GS001-Q000 1 Rotary handle operating mechanism RHE normal for fixed and plug-in T4 - T5 054929 ABB
==00EAD03=GS001-Q000 1 auxiliary contact AUX -C3Q 1SY 24V DC for T4-T5-T6 1SDA054915R1 ABB
B B
==00EAD03=GS001-T001 1 bushing type current transformer MBS ASK31.4 200A/1A 10VA ASK 31.4 MBS GmbH
==00EAD03=GS001-T002 1 bushing type current transformer MBS ASK31.4 200A/1A 10VA ASK 31.4 MBS GmbH
==00EAD03=GS001-T003 1 bushing type current transformer MBS ASK31.4 200A/1A 10VA ASK 31.4 MBS GmbH
C C
D D
E E
F F
G G
+F01-5/146 +F02/148
Date 13.10.2011 2.2040 PARTLIST
Parts list Stacker
Ed. by cw-de + F01-6
Appr. VUNG ANG Page 147
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Quantity
Device tag Designation Type Number Supplier
==00EAD03=AE002-E001 1 Cabinet heating Typ 4 „LM-Long“ 230V 375 W IP 52 internal thermostat TYP4/230V/375W/IP52/THERMOSTATLM Heizungen
F F
G G
+F01-6/147 +F02-7/149
Date 13.10.2011 2.2040 PARTLIST
Parts list Stacker
Ed. by cw-de + F02
Appr. VUNG ANG Page 148
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Quantity
Device tag Designation Type Number Supplier
==00EAD03=GR002-G001 1 SITOP POWER 10 STABILIZED POWER SUPPLY 400-500 V AC OUTPUT: 24 V DC/10 A 6EP1434-2BA10 SIEMENS
==00EAD03=AE002-XT001 1 Component terminal block, Connection method: Screw connection, Width: 8.2 mm, Mounting type: NS 35/7,5, NS 35/15, NS 32, Color: gray 0313085 Phoenix Contact
==00EAD03=AP010-XT001 1 Component terminal block, Connection method: Screw connection, Width: 8.2 mm, Mounting type: NS 35/7,5, NS 35/15, NS 32, Color: gray 0313085 Phoenix Contact
+F02/148 150
Date 13.10.2011 2.2040 PARTLIST
Parts list Stacker
Ed. by cw-de + F02-7
Appr. VUNG ANG Page 149
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Quantity
Device tag Designation Type Number Supplier
==00EAD03=AP020-XT001 1 Component terminal block, Connection method: Screw connection, Width: 8.2 mm, Mounting type: NS 35/7,5, NS 35/15, NS 32, Color: gray 0313085 Phoenix Contact
B B
==00EAD03=AE004-F001 1 Circuit breaker C1 A S201-M-C1 ABB
==00EAD03=AE004-XT001 1 Component terminal block, Connection method: Screw connection, Width: 8.2 mm, Mounting type: NS 35/7,5, NS 35/15, NS 32, Color: gray 0313085 Phoenix Contact
==00EAD03=GP001-Q002 1 Block Contactors A9-30-22 4 kW 400V 2NO/2NC coil voltage 110V AC A9-30-22 ABB
==00EAD03=GP001-Q002 1 Diode suppressor contactor choke RV 5/250 110...250 AC/DC A9...A110 RV 5/250 ABB
==00EAD03=GP001-Q003 1 Block Contactors A9-30-22 4 kW 400V 2NO/2NC coil voltage 110V AC A9-30-22 ABB
G G
149 151
Date 13.10.2011 2.2040 PARTLIST
Parts list Stacker
Ed. by cw-de + F02-7
Appr. VUNG ANG Page 150
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Quantity
Device tag Designation Type Number Supplier
==00EAD03=GP001-Q003 1 Diode suppressor contactor choke RV 5/250 110...250 AC/DC A9...A110 RV 5/250 ABB
==00EAD03=EH001-G001 1 Uninterruptible power supply with integrated power supply unit, 5A, in combination with MINI-BAT/24/DC/1.3 AH, QUINT-BAT/24DC 3,4AH, 7,2AH or 12 AH TRIO-UPS/1AC/24DC/ 5 Phoenix Contact
==00EAD03=EH001-G002 1 Rechargeable battery module, lead AGM, VRLA technology, 24 V DC, 1.3 Ah. MINI-BAT/24DC/1.3AH Phoenix Contact
G G
150 +F03/152
Date 13.10.2011 2.2040 PARTLIST
Parts list Stacker
Ed. by cw-de + F02-7
Appr. VUNG ANG Page 151
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Quantity
Device tag Designation Type Number Supplier
==00EAD03=AE001-A001 1 SIRIUS SAFETY RELAY WITH RELAY RELEASE CIRCUITS (FK) 3TK2827-1AB21 SIEMENS
==00EAD03=AE001-Q004 1 Block Contactors A9-30-22 4 kW 400V 2NO/2NC coil voltage 110V AC A9-30-22 ABB
B B
==00EAD03=AE001-Q004 1 Diode suppressor contactor choke RV 5/250 110...250 AC/DC A9...A110 RV 5/250 ABB
SIMATIC DP,BUS CONNECTOR FOR PROFIBUS UP TO 12 MBIT/S 90 DEGREE ANGLE CABLE OUTLET, IPCD TECHOLOGY FAST CONNECT, WITH PG SOCKET
==00EAD03=AE001-T002 1 6ES7972-0BB52-0XA0 SIEMENS
15,8 X 59 X 35,6 MM (WXHXD),
==00EAD03=AH003-M01 1 OUTLET FILTER FOR FAN-AND-FILTER UNIT 3326 RAL7035 SK3326.207 Rittal
==00EAD03=CH102-A001 1 SIRIUS SAFETY RELAY WITH RELAY RELEASE CIRCUITS (RC) 3TK2826-1CW30 SIEMENS
==00EAD03=CH102-A002 1 SIRIUS SAFETY RELAY WITH RELAY RELEASE CIRCUITS (FK) 3TK2830-1CB30 SIEMENS
G G
+F02-7/151 +F04/153
Date 13.10.2011 2.2040 PARTLIST
Parts list Stacker
Ed. by cw-de + F03
Appr. VUNG ANG Page 152
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Quantity
Device tag Designation Type Number Supplier
+F03/152 154
Date 13.10.2011 2.2040 PARTLIST
Parts list Stacker
Ed. by cw-de + F04
Appr. VUNG ANG Page 153
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Quantity
Device tag Designation Type Number Supplier
==00EAD03=GR001-G001 1 SITOP POWER 10 STABILIZED POWER SUPPLY 400-500 V AC OUTPUT: 24 V DC/10 A 6EP1434-2BA10 SIEMENS
==00EAD03=GR001-X6 1 Component terminal block, Connection method: Screw connection, Width: 8.2 mm, Mounting type: NS 35/7,5, NS 35/15, NS 32, Color: gray 0313085 Phoenix Contact
F F
==00EAD03=AH002-E004 1 Cabinet Heater100 W, 230V-HP GHV010100V0006 ABB
SIMATIC S7-300 CPU 315-2 PN/DP, CENTRAL PROCESSING UNIT WITH 384 KBYTE WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE
==00EAD03=EH001-A02 1 6ES7315-2EH14-0AB0 SIEMENS
ETHERNET PROFINET, WITH 2 PORT SWITCH, MICRO MEMORY CARD NECESSARY
G G
153 155
Date 13.10.2011 2.2040 PARTLIST
Parts list Stacker
Ed. by cw-de + F04
Appr. VUNG ANG Page 154
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Quantity
Device tag Designation Type Number Supplier
==00EAD03=EH001-A02 1 SIMATIC S7, MICRO MEMORY CARD P. S7-300/C7/ET 200, 3.3 V NFLASH, 2 MBYTES 6ES7953-8LL20-0AA0 SIEMENS
SIMATIC DP,BUS CONNECTOR FOR PROFIBUS UP TO 12 MBIT/S 90 DEGREE ANGLE CABLE OUTLET, IPCD TECHOLOGY FAST CONNECT, WITH PG SOCKET
==00EAD03=EH001-A02 1 6ES7972-0BB52-0XA0 SIEMENS
15,8 X 59 X 35,6 MM (WXHXD),
==00EAD03=EH001-A05 1 SIMATIC S7-300, DIGITAL INPUT SM 321, OPTICALLY ISOLATED 32DI, 24 V DC, 1 X 40 PIN 6ES7321-1BL00-0AA0 SIEMENS
==00EAD03=EH001-A06 1 SIMATIC S7-300, DIGITAL INPUT SM 321, OPTICALLY ISOLATED 32DI, 24 V DC, 1 X 40 PIN 6ES7321-1BL00-0AA0 SIEMENS
C C
==00EAD03=EH001-A06 1 S7 front plug 40-poles w/ terminals 6ES7392-1AM00-0AA0 SIEMENS
==00EAD03=EH001-A07 1 SIMATIC S7-300, DIGITAL INPUT SM 321, OPTICALLY ISOLATED 32DI, 24 V DC, 1 X 40 PIN 6ES7321-1BL00-0AA0 SIEMENS
==00EAD03=EH001-A08 1 SIMATIC S7-300, DIGITAL INPUT SM 321, OPTICALLY ISOLATED 32DI, 24 V DC, 1 X 40 PIN 6ES7321-1BL00-0AA0 SIEMENS
==00EAD03=EH001-A11 1 SIMATIC S7-300,INTERFACE MODULE IM 365 FOR CONNECTING AN EXPANSION RACK, W/O K-BUS, 2 MODULES + CONNECTING CABLE 1M 6ES7365-0BA01-0AA0 SIEMENS
E E
==00EAD03=EH001-A12 1 SIMATIC S7-300, analog input SM 331 S7 SIEMENS
==00EAD03=EH001-A12 1 SIMATIC S7-300, FRONT CONNECTOR FOR SIGNAL MODULES WITH SCREW CONTACTS, 20-PIN 6ES7392-1AJ00-0AA0 SIEMENS
SIMATIC S7-300, ANALOG OUTPUT SM 332, OPTICALLY ISOLATED, 2 AO, U/I; 11/12 BITS RESOL., 20 PIN., REMOVE/INSERT WITH ACTIVE BACKPLANE
==00EAD03=EH001-A13 1 6ES7332-5HB01-0AB0 SIEMENS
BUS
==00EAD03=EH001-A13 1 SIMATIC S7-300, FRONT CONNECTOR FOR SIGNAL MODULES WITH SCREW CONTACTS, 20-PIN 6ES7392-1AJ00-0AA0 SIEMENS
==00EAD03=EH001-A200 1 SCALANCE X204-2, MANAGED IE SWITCH, 4 X 10/100MBIT/S RJ45 PORTS 6GK5204-2BB10-2AA3 SIEMENS
F F
==00EAD03=EH001-K010 1 pluggable interface relay CR-P024DC1, 24V (1CO) CR-P024DC1 ABB
154 156
Date 13.10.2011 2.2040 PARTLIST
Parts list Stacker
Ed. by cw-de + F04
Appr. VUNG ANG Page 155
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Quantity
Device tag Designation Type Number Supplier
==00EAD03=CP121-S004 1 Sensor/Actuator cable, 3-position, Free conductor end, on Valve plug A, with 1 LED, connected with Varistor, Cable length: 10 m SAC-3P-10,0-PUR/A-1L-V Phoenix Contact
==00EAC03=CT101-S001 1 POSITION SWITCH, METAL-ENCLOSED SNAP-ACTION CONTACTS 1NO+1NC, OVERTRAVEL PLUNGER TYPE B, 1 X M20 X 1,5 3SE2120-1C SIEMENS
G G
155 157
Date 13.10.2011 2.2040 PARTLIST
Parts list Stacker
Ed. by cw-de + F04
Appr. VUNG ANG Page 156
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Quantity
Device tag Designation Type Number Supplier
==00EAC51=CL101-U001 1 2-CHANNEL SERIAL BINARY TRANSMISSION FIBRE OPTIC CABLE 820NM 7XV5653-0BA00 SIEMENS
B B
C C
D D
E E
F F
G G
156 +A008/158
Date 13.10.2011 2.2040 PARTLIST
Parts list Stacker
Ed. by cw-de + F04
Appr. VUNG ANG Page 157
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Quantity
Device tag Designation Type Number Supplier
==00EAD03=GS001-XF 1 FIBER OPTIC SPLICE DISTRIBUTOR FOR TH35 RAIL 150240C30610E BTR
==00EAD03=GS001-XT001 1 Component terminal block, Connection method: Screw connection, Width: 8.2 mm, Mounting type: NS 35/7,5, NS 35/15, NS 32, Color: gray 0313085 Phoenix Contact
E E
F F
G G
+F04/157 +A009/159
Date 13.10.2011 2.2040 PARTLIST
Parts list Stacker
Ed. by cw-de + A008
Appr. VUNG ANG Page 158
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Quantity
Device tag Designation Type Number Supplier
==00EAD03=CBL 1 Compact enclosure AE, painted RAL 7032, single door, with mount. plate AE1039.600 Rittal
==00EAD03=CBL 1 WALL MOUNTING BRACKET BRASS; NICKELPLATED FOR STAINL.STEEL KL1580.000 Rittal
C C
D D
E E
F F
G G
+A008/158 +A010/160
Date 13.10.2011 2.2040 PARTLIST
Parts list Stacker
Ed. by cw-de + A009
Appr. VUNG ANG Page 159
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Quantity
Device tag Designation Type Number Supplier
==00EAD03=CBL 1 WALL MOUNTING BRACKET BRASS; NICKELPLATED FOR STAINL.STEEL KL1580.000 Rittal
D D
E E
F F
G G
+A009/159 +LC01/161
Date 13.10.2011 2.2040 PARTLIST
Parts list Stacker
Ed. by cw-de + A010
Appr. VUNG ANG Page 160
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Quantity
Device tag Designation Type Number Supplier
==00EAD03=AH003-M01 1 Fan-and-filter unit, 55 m³/h 230 V, 50/60 RAL 7035 SK3322.107 Rittal
==CBL=CBL 1 One-piece console single door painted RAL 7032 600 mm x 960 mm x 400 mm AP2666.600 Rittal
C C
D D
E E
F F
G G
+A010/160 +GY/162
Date 13.10.2011 2.2040 PARTLIST
Parts list Stacker
Ed. by cw-de + LC01
Appr. VUNG ANG Page 161
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Quantity
Device tag Designation Type Number Supplier
==00EAD03=AE002-Y003 1 Sensor/Actuator cable, 3-position, Free conductor end, on Valve plug A, with 1 LED, connected with Varistor, Cable length: 10 m SAC-3P-10,0-PUR/A-1L-V Phoenix Contact
==00EAD03=AE002-Y004 1 Sensor/Actuator cable, 3-position, Free conductor end, on Valve plug A, with 1 LED, connected with Varistor, Cable length: 10 m SAC-3P-10,0-PUR/A-1L-V Phoenix Contact
C C
==00EAD03=AE002-Y005 1 4/2 port-valve- NG6 D1VW016FNJW91 PARKER
==00EAD03=AE002-Y005 1 Sensor/Actuator cable, 3-position, Free conductor end, on Valve plug A, with 1 LED, connected with Varistor, Cable length: 10 m SAC-3P-10,0-PUR/A-1L-V Phoenix Contact
==00EAD03=AE002-Y006 1 Sensor/Actuator cable, 3-position, Free conductor end, on Valve plug A, with 1 LED, connected with Varistor, Cable length: 10 m SAC-3P-10,0-PUR/A-1L-V Phoenix Contact
==00EAD03=AE002-Y008 1 Sensor/Actuator cable, 3-position, Free conductor end, on Valve plug A, with 1 LED, connected with Varistor, Cable length: 10 m SAC-3P-10,0-PUR/A-1L-V Phoenix Contact
==00EAD03=AE002-Y009 1 Sensor/Actuator cable, 3-position, Free conductor end, on Valve plug A, with 1 LED, connected with Varistor, Cable length: 10 m SAC-3P-10,0-PUR/A-1L-V Phoenix Contact
E E
==00EAD03=CL121-B004 1 Level/temperature display and monitoring 1 switching output, 1 analog output, connector M12 (4 pin), SCLTSD-370-10-07 PARKER
==00EAD03=CL121-B004 1 Sensor/actuator connector, female, straight, 5-pos., M12 SPEEDCON, A-coded, screw connection, metal knurl, cable screw connection PG 7 SACC-FS-5CON-PG 7-M SCO Phoenix Contact
==00EAD03=CP001-B001 1 Sensor/actuator connector, female, straight, 5-pos., M12 SPEEDCON, A-coded, screw connection, metal knurl, cable screw connection PG 7 SACC-FS-5CON-PG 7-M SCO Phoenix Contact
==00EAD03=CP003-B003 1 Sensor/actuator connector, female, straight, 5-pos., M12 SPEEDCON, A-coded, screw connection, metal knurl, cable screw connection PG 7 SACC-FS-5CON-PG 7-M SCO Phoenix Contact
G G
+LC01/161 +X/163
Date 13.10.2011 2.2040 PARTLIST
Parts list Stacker
Ed. by cw-de + GY
Appr. VUNG ANG Page 162
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Quantity
Device tag Designation Type Number Supplier
==00EAD03=GP001-E02 1 Dustproof/Waterproof Polyester Light Fitting with Diffuser - Insulation Class II 1x58W 161158AUS SCHUCH
==00EAD03=GP001-E03 1 COMBI MARITIM 607 Damp proof Junction Boxes 6 mm² COMBI_MAR_607/5 WISKA
==00EAD03=GP001-E04 1 Dustproof/Waterproof Polyester Light Fitting with Diffuser - Insulation Class II 1x58W 161158AUS SCHUCH
==00EAD03=GP001-E06 1 Dustproof/Waterproof Polyester Light Fitting with Diffuser - Insulation Class II 1x58W 161158AUS SCHUCH
==00EAD03=GP001-E07 1 COMBI MARITIM 607 Damp proof Junction Boxes 6 mm² COMBI_MAR_607/5 WISKA
==00EAD03=GP001-E08 1 Dustproof/Waterproof Polyester Light Fitting with Diffuser - Insulation Class II 1x58W 161158AUS SCHUCH
D D
==00EAD03=GP001-E08 1 fluorescent tube 58 W TL-D-SUPER80-58W-840 Philips
==00EAD03=GP001-E09 1 COMBI MARITIM 607 Damp proof Junction Boxes 6 mm² COMBI_MAR_607/5 WISKA
==00EAD03=GP001-E10 1 Dustproof/Waterproof Polyester Light Fitting with Diffuser - Insulation Class II 1x58W 161158AUS SCHUCH
==00EAD03=GP001-E11 1 COMBI MARITIM 607 Damp proof Junction Boxes 6 mm² COMBI_MAR_607/5 WISKA
E E
==00EAD03=GP001-E12 1 Dustproof/Waterproof Polyester Light Fitting with Diffuser - Insulation Class II 1x58W 161158AUS SCHUCH
==00EAD03=GP001-E13 1 COMBI MARITIM 607 Damp proof Junction Boxes 6 mm² COMBI_MAR_607/5 WISKA
==00EAD03=GP001-E14 1 Dustproof/Waterproof Polyester Light Fitting with Diffuser - Insulation Class II 1x58W 161158AUS SCHUCH
==00EAD03=GP001-E16 1 Dustproof/Waterproof Polyester Light Fitting with Diffuser - Insulation Class II 1x58W 161158AUS SCHUCH
==00EAD03=GP001-E17 1 COMBI MARITIM 607 Damp proof Junction Boxes 6 mm² COMBI_MAR_607/5 WISKA
==00EAD03=GP001-E18 1 Dustproof/Waterproof Polyester Light Fitting with Diffuser - Insulation Class II 1x58W 161158AUS SCHUCH
G G
+GY/162 164
Date 13.10.2011 2.2040 PARTLIST
Parts list Stacker
Ed. by cw-de +X
Appr. VUNG ANG Page 163
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Quantity
Device tag Designation Type Number Supplier
==00EAD03=GP001-E19 1 COMBI MARITIM 607 Damp proof Junction Boxes 6 mm² COMBI_MAR_607/5 WISKA
==00EAD03=GP001-E20 1 Dustproof/Waterproof Polyester Light Fitting with Diffuser - Insulation Class II 1x58W 161158AUS SCHUCH
B B
==00EAD03=GP001-E20 1 fluorescent tube 58 W TL-D-SUPER80-58W-840 Philips
==00EAD03=GP001-E21 1 COMBI MARITIM 607 Damp proof Junction Boxes 6 mm² COMBI_MAR_607/5 WISKA
==00EAD03=GP001-E22 1 Dustproof/Waterproof Polyester Light Fitting with Diffuser - Insulation Class II 1x58W 161158AUS SCHUCH
==00EAD03=GP001-E23 1 COMBI MARITIM 607 Damp proof Junction Boxes 6 mm² COMBI_MAR_607/5 WISKA
C C
==00EAD03=GP001-E24 1 Dustproof/Waterproof Polyester Light Fitting with Diffuser - Insulation Class II 1x58W 161158AUS SCHUCH
==00EAD03=GP001-E25 1 COMBI MARITIM 607 Damp proof Junction Boxes 6 mm² COMBI_MAR_607/5 WISKA
==00EAD03=GP001-E26 1 Dustproof/Waterproof Polyester Light Fitting with Diffuser - Insulation Class II 1x58W 161158AUS SCHUCH
==00EAD03=GP001-E28 1 Dustproof/Waterproof Polyester Light Fitting with Diffuser - Insulation Class IIfor outdoor installation 162 258 AUS SCHUCH
==00EAD03=GP001-X01 1 SCHUKO socket-outlet 16 A, AC 250 V, DIN 49440 With labelling option and labelling insert. With plug-in terminals. 238039 MERTEN
==00EAD03=AH001-A01 1 SUPPLY- AND SPENT AIR FOR SHELTER UNIT YT/AG_100405 YORK
==00EAD03=EH001-P001 1 Sounder-Strobe Light-Combination type YL5, 24 VDC, Lens colour amber 25511303 FHF GmbH
F F
SIRIUS POSITION SWITCH PLASTIC HOUSING ACC. TO EN50047, 31MM DEVICE CONNECTION 1X(M20X1.5); 1NO/1NC SLOW-ACTION CONTACTS
==00EAD03=EH001-S001 1 3SE5232-0BF10 SIEMENS
ANGULAR ROLLER PLUNGER W. PLASTIC ROLLER 13MM
==00EAD03=EH001-S002 1 Rocker button 10 A, 250 V AC Illuminated. With plug-in terminals as connecting terminals in accordance with VDE 0632. 375975 MERTEN
==00EAD03=EH001-S003 1 Rocker button 10 A, 250 V AC Illuminated. With plug-in terminals as connecting terminals in accordance with VDE 0632. 375975 MERTEN
==00EAD03=EH001-S004 1 Rocker button 10 A, 250 V AC Illuminated. With plug-in terminals as connecting terminals in accordance with VDE 0632. 375975 MERTEN
163 165
Date 13.10.2011 2.2040 PARTLIST
Parts list Stacker
Ed. by cw-de +X
Appr. VUNG ANG Page 164
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Quantity
Device tag Designation Type Number Supplier
==00EAD03=CG003-B01 1 Compact transmitters for non-contact level measurement of fluids, pastes and coarse bulk materials FMU42-AMB2A22A Endress+Hauser
==00EAD03=CG004-B02 1 Compact transmitters for non-contact level measurement of fluids, pastes and coarse bulk materials FMU42-AMB2A22A Endress+Hauser
B B
==00EAD03=CG005-B03 1 Compact transmitters for non-contact level measurement of fluids, pastes and coarse bulk materials FMU42-AMB2A22A Endress+Hauser
==00EAD03=CH101 1 ENCLOSURE FOR 22MM PROGRAM PLASTIC VERSION 3 COMMAND POSITIONS GRAY TOP PART 3SB3803-0AA3 SIEMENS
==00EAD03=CH101-S001 1 22MM PLASTIC ROUND ACTUATOR: RONIS LOCK WITH 2 KEYS 2 SWITCH POSITIONS O-I 3SB3000-4HD21 SIEMENS
==00EAD03=CH101-S001 1 COMPONENT FOR ENCLOSURE, 22MM CONTACT BLOCK WITH 1 CONTACT ELEMENT SCREW TERMINAL, 1NO 3SB3420-0B SIEMENS
==00EAD03=CH101-S001 1 COMPONENT FOR ENCLOSURE, 22MM CONTACT BLOCK WITH 1 CONTACT ELEMENT SCREW TERMINAL, 1NC 3SB3420-0C SIEMENS
C C
==00EAD03=CH101-S001 1 INSCRIPTION LABEL FOR GLUING ON ENCLOSURE, LABEL SIZE 22 X 22MM, SILVER-COLORED, BLACK LETTERING, LOCK NUMBER 3SB1901-3XZK1YZ1REMOTEZ2LOCALSIEMENS
==00EAD03=CH101-S002 1 22MM PLASTIC ROUND ACTUATOR: PUSHBUTTON WITH FLAT BUTTON WITH HOLDER GREEN 3SB3000-0AA41 SIEMENS
==00EAD03=CH101-S002 1 COMPONENT FOR ENCLOSURE, 22MM CONTACT BLOCK WITH 1 CONTACT ELEMENT SCREW TERMINAL, 1NO 3SB3420-0B SIEMENS
INSCRIPTION LABEL FOR GLUING ON ENCLOSURE, LABEL SIZE 22 X 22MM, SILVER-COLORED, BLACK LETTERING, WITH INSCRIPTION: START
==00EAD03=CH101-S002 1 3SB1901-3EL SIEMENS
SILVER-COLORED, BLACK LETTERING
==00EAD03=CH101-S003 1 22MM PLASTIC ROUND ACTUATOR: PUSHBUTTON WITH FLAT BUTTON WITH HOLDER RED 3SB3000-0AA21 SIEMENS
D D
==00EAD03=CH101-S003 1 COMPONENT FOR ENCLOSURE, 22MM CONTACT BLOCK WITH 1 CONTACT ELEMENT SCREW TERMINAL, 1NC 3SB3420-0C SIEMENS
INSCRIPTION LABEL FOR GLUING ON ENCLOSURE, LABEL SIZE 22 X 22MM, SILVER-COLORED, BLACK LETTERING, WITH INSCRIPTION: STOP
==00EAD03=CH101-S003 1 3SB1901-3EK SIEMENS
SILVER-COLORED, BLACK LETTERING
ENCLOSURE FOR 22MM PROGRAM PLASTIC VERSION 1 COMMAND POSITION YELLOW TOP PART WITH PROTECTIVE COLLAR A=EMER.-STOP40MM
==00EAD03=CH102-S001 1 3SB3801-0EF3 SIEMENS
ROT.-TO-UNLAT. 2NC
==00EAD03=CH102-S001 1 COMPONENT FOR ENCLOSURE, 22MM CONTACT BLOCK WITH 1 CONTACT ELEMENT SCREW TERMINAL, 1NO 3SB3420-0B SIEMENS
==00EAD03=CH111 1 ENCLOSURE FOR 22MM PROGRAM PLASTIC VERSION 3 COMMAND POSITIONS GRAY TOP PART 3SB3803-0AA3 SIEMENS
E E
==00EAD03=CH111-S001 1 22MM PLASTIC ROUND ACTUATOR: RONIS LOCK WITH 2 KEYS 2 SWITCH POSITIONS O-I 3SB3000-4HD21 SIEMENS
==00EAD03=CH111-S001 1 COMPONENT FOR ENCLOSURE, 22MM CONTACT BLOCK WITH 1 CONTACT ELEMENT SCREW TERMINAL, 1NO 3SB3420-0B SIEMENS
==00EAD03=CH111-S001 1 COMPONENT FOR ENCLOSURE, 22MM CONTACT BLOCK WITH 1 CONTACT ELEMENT SCREW TERMINAL, 1NC 3SB3420-0C SIEMENS
==00EAD03=CH111-S001 1 INSCRIPTION LABEL FOR GLUING ON ENCLOSURE, LABEL SIZE 22 X 22MM, SILVER-COLORED, BLACK LETTERING, LOCK NUMBER 3SB1901-3XZK1YZ1REMOTEZ2LOCALSIEMENS
==00EAD03=CH111-S002 1 22MM PLASTIC ROUND ACTUATOR: PUSHBUTTON WITH FLAT BUTTON WITH HOLDER GREEN 3SB3000-0AA41 SIEMENS
F F
==00EAD03=CH111-S002 1 COMPONENT FOR ENCLOSURE, 22MM CONTACT BLOCK WITH 1 CONTACT ELEMENT SCREW TERMINAL, 1NO 3SB3420-0B SIEMENS
==00EAD03=CH111-S002 1 INSCRIPTION LABEL FOR GLUING ON ENCLOSURE, LABEL SIZE 22 X 22MM, SILVER-COLORED, BLACK LETTERING, LOCK NUMBER 3SB1901-3XZK1YFORWARD SIEMENS
==00EAD03=CH111-S003 1 22MM PLASTIC ROUND ACTUATOR: PUSHBUTTON WITH FLAT BUTTON WITH HOLDER GREEN 3SB3000-0AA41 SIEMENS
==00EAD03=CH111-S003 1 COMPONENT FOR ENCLOSURE, 22MM CONTACT BLOCK WITH 1 CONTACT ELEMENT SCREW TERMINAL, 1NO 3SB3420-0B SIEMENS
==00EAD03=CH111-S003 1 INSCRIPTION LABEL FOR GLUING ON ENCLOSURE, LABEL SIZE 22 X 22MM, SILVER-COLORED, BLACK LETTERING, LOCK NUMBER 3SB1901-3XZK1YBACKWARD SIEMENS
G G
164 166
Date 13.10.2011 2.2040 PARTLIST
Parts list Stacker
Ed. by cw-de +X
Appr. VUNG ANG Page 165
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Quantity
Device tag Designation Type Number Supplier
ENCLOSURE FOR 22MM PROGRAM PLASTIC VERSION 1 COMMAND POSITION YELLOW TOP PART WITH PROTECTIVE COLLAR A=EMER.-STOP40MM
==00EAD03=CH112-S002 1 3SB3801-0EF3 SIEMENS
ROT.-TO-UNLAT. 2NC
==00EAD03=CH112-S002 1 COMPONENT FOR ENCLOSURE, 22MM CONTACT BLOCK WITH 1 CONTACT ELEMENT SCREW TERMINAL, 1NO 3SB3420-0B SIEMENS
ENCLOSURE FOR 22MM PROGRAM PLASTIC VERSION 1 COMMAND POSITION YELLOW TOP PART WITH PROTECTIVE COLLAR A=EMER.-STOP40MM
==00EAD03=CH113-S003 1 3SB3801-0EF3 SIEMENS
ROT.-TO-UNLAT. 2NC
B B
==00EAD03=CH113-S003 1 COMPONENT FOR ENCLOSURE, 22MM CONTACT BLOCK WITH 1 CONTACT ELEMENT SCREW TERMINAL, 1NO 3SB3420-0B SIEMENS
ENCLOSURE FOR 22MM PROGRAM PLASTIC VERSION 1 COMMAND POSITION YELLOW TOP PART WITH PROTECTIVE COLLAR A=EMER.-STOP40MM
==00EAD03=CH114-S004 1 3SB3801-0EF3 SIEMENS
ROT.-TO-UNLAT. 2NC
==00EAD03=CH114-S004 1 COMPONENT FOR ENCLOSURE, 22MM CONTACT BLOCK WITH 1 CONTACT ELEMENT SCREW TERMINAL, 1NO 3SB3420-0B SIEMENS
ENCLOSURE FOR 22MM PROGRAM PLASTIC VERSION 1 COMMAND POSITION YELLOW TOP PART WITH PROTECTIVE COLLAR A=EMER.-STOP40MM
==00EAD03=CH115-S005 1 3SB3801-0EF3 SIEMENS
ROT.-TO-UNLAT. 2NC
==00EAD03=CH115-S005 1 COMPONENT FOR ENCLOSURE, 22MM CONTACT BLOCK WITH 1 CONTACT ELEMENT SCREW TERMINAL, 1NO 3SB3420-0B SIEMENS
C C
==00EAD03=CH121 1 ENCLOSURE FOR 22MM PROGRAM PLASTIC VERSION 3 COMMAND POSITIONS GRAY TOP PART 3SB3803-0AA3 SIEMENS
==00EAD03=CH121-S004 1 22MM PLASTIC ROUND ACTUATOR: RONIS LOCK WITH 2 KEYS 2 SWITCH POSITIONS O-I 3SB3000-4HD21 SIEMENS
==00EAD03=CH121-S004 1 COMPONENT FOR ENCLOSURE, 22MM CONTACT BLOCK WITH 1 CONTACT ELEMENT SCREW TERMINAL, 1NO 3SB3420-0B SIEMENS
==00EAD03=CH121-S004 1 COMPONENT FOR ENCLOSURE, 22MM CONTACT BLOCK WITH 1 CONTACT ELEMENT SCREW TERMINAL, 1NC 3SB3420-0C SIEMENS
==00EAD03=CH121-S004 1 INSCRIPTION LABEL FOR GLUING ON ENCLOSURE, LABEL SIZE 22 X 22MM, SILVER-COLORED, BLACK LETTERING, LOCK NUMBER 3SB1901-3XZK1YZ1REMOTEZ2LOCALSIEMENS
D D
==00EAD03=CH121-S005 1 22MM PLASTIC ROUND ACTUATOR: PUSHBUTTON WITH FLAT BUTTON WITH HOLDER GREEN 3SB3000-0AA41 SIEMENS
==00EAD03=CH121-S005 1 COMPONENT FOR ENCLOSURE, 22MM CONTACT BLOCK WITH 1 CONTACT ELEMENT SCREW TERMINAL, 1NO 3SB3420-0B SIEMENS
==00EAD03=CH121-S005 1 INSCRIPTION LABEL FOR GLUING ON ENCLOSURE, LABEL SIZE 22 X 22MM, SILVER-COLORED, BLACK LETTERING, LOCK NUMBER 3SB1901-3XZK1YUP SIEMENS
==00EAD03=CH121-S006 1 22MM PLASTIC ROUND ACTUATOR: PUSHBUTTON WITH FLAT BUTTON WITH HOLDER GREEN 3SB3000-0AA41 SIEMENS
==00EAD03=CH121-S006 1 COMPONENT FOR ENCLOSURE, 22MM CONTACT BLOCK WITH 1 CONTACT ELEMENT SCREW TERMINAL, 1NO 3SB3420-0B SIEMENS
E E
==00EAD03=CH121-S006 1 INSCRIPTION LABEL FOR GLUING ON ENCLOSURE, LABEL SIZE 22 X 22MM, SILVER-COLORED, BLACK LETTERING, LOCK NUMBER 3SB1901-3XZK1YDOWN SIEMENS
ENCLOSURE FOR 22MM PROGRAM PLASTIC VERSION 1 COMMAND POSITION YELLOW TOP PART WITH PROTECTIVE COLLAR A=EMER.-STOP40MM
==00EAD03=CH122-S006 1 3SB3801-0EF3 SIEMENS
ROT.-TO-UNLAT. 2NC
==00EAD03=CH122-S006 1 COMPONENT FOR ENCLOSURE, 22MM CONTACT BLOCK WITH 1 CONTACT ELEMENT SCREW TERMINAL, 1NO 3SB3420-0B SIEMENS
==00EAD03=CH122-S007 1 ACTUATOR-/INDICATOR COMPONENT CONTACT BLOCK WITH 1 CONTACT ELEMENT SCREW TERMINAL, 1NC 3SB3400-0C SIEMENS
F F
==00EAD03=CH122-S007 1 PROTECTIVE COLLAR YELLOW FOR MUSHR.PUSHBUTTON 3SB3921-0AK SIEMENS
==00EAD03=CH122-S007 1 ACTUATOR-/INDICATOR COMPONENT CONTACT BLOCK WITH 1 CONTACT ELEMENT SCREW TERMINAL, 1NO 3SB3400-0B SIEMENS
==00EAD03=CG117-S004 1 Position and limit switch 1NO, 1NC snap action MD250-11z SCHMERSAL
==00EAD03=CG118-S005 1 Position and limit switch 1NO, 1NC snap action MD250-11z SCHMERSAL
G G
165 167
Date 13.10.2011 2.2040 PARTLIST
Parts list Stacker
Ed. by cw-de +X
Appr. VUNG ANG Page 166
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Quantity
Device tag Designation Type Number Supplier
==00EAD03=CG119-S002 1 Position and limit switch 1NO, 1NC snap action MD250-11z SCHMERSAL
==00EAD03=CG120-S003 1 Position and limit switch 1NO, 1NC snap action MD250-11z SCHMERSAL
==00EAD03=CG121-S004 1 Position switch / 335 Metal enclosure - DIN EN 50041 with Actuator / 335 Roller lever 7H (NO/NC) Snap switch element Z4V7H 335-11Z SCHMERSAL
B B
==00EAD03=CG122-S005 1 Position switch / 335 Metal enclosure - DIN EN 50041 with Actuator / 335 Roller lever 7H (NO/NC) Snap switch element Z4V7H 335-11Z SCHMERSAL
==00EAD03=CG123-S006 1 Position switch / 335 Metal enclosure - DIN EN 50041 with Actuator / 335 Roller lever 7H (NO/NC) Snap switch element Z4V7H 335-11Z SCHMERSAL
DITTELBACH &
==00EAC03=CH111-S001 4 Rope thimble stainless steel SKA3-VA
KERZLER
DITTELBACH &
==00EAC03=CH111-S001 8 Rope clamp stainless steel SKL3-VA
KERZLER
C C
DITTELBACH &
==00EAC03=CH111-S001 2 Tension Spring stainless steel SPF-W
KERZLER
DITTELBACH &
==00EAC03=CH111-S001 2 Rope tension lock stainless steel SPS6-VA
KERZLER
DITTELBACH &
==00EAC03=CH112-S002 4 Rope thimble stainless steel SKA3-VA
KERZLER
DITTELBACH &
==00EAC03=CH112-S002 8 Rope clamp stainless steel SKL3-VA
KERZLER
D D
DITTELBACH &
==00EAC03=CH112-S002 2 Tension Spring stainless steel SPF-W
KERZLER
DITTELBACH &
==00EAC03=CH112-S002 2 Rope tension lock stainless steel SPS6-VA
KERZLER
Hans Turck GmbH &
==00EAC03=CG104-S001 1 Inductive sensor Threaded barrel, M18 x 1 NO contact, Cable connection, DC 2-wire, 10…300 VDC BI5-M18-AZ3X
Co. KG
==00EAC03=CG104-S001 1 COMBI MARITIM 308 Damp proof Junction Boxes 2,5mm² COMBI_MAR_308/5 WISKA
DITTELBACH &
==00EAC03=CG102-S001 1 Conveyor belt misalignment switch LHPE-10/2-L50V
KERZLER
E E
Hans Turck GmbH &
==00EAC03=CS101-S001 1 inductive sensor rotational speed monitor DBi10U-M30-AP4X2
Co. KG
==00EAC03=CS101-S001 1 COMBI MARITIM 308 Damp proof Junction Boxes 2,5mm² COMBI_MAR_308/5 WISKA
DITTELBACH &
==00EAC51=CH121-S001 4 Rope thimble stainless steel SKA3-VA
KERZLER
DITTELBACH &
==00EAC51=CH121-S001 8 Rope clamp stainless steel SKL3-VA
KERZLER
F F
DITTELBACH &
==00EAC51=CH121-S001 2 Tension Spring stainless steel SPF-W
KERZLER
DITTELBACH &
==00EAC51=CH121-S001 2 Rope tension lock stainless steel SPS6-VA
KERZLER
DITTELBACH &
==00EAC51=CH122-S002 4 Rope thimble stainless steel SKA3-VA
KERZLER
DITTELBACH &
==00EAC51=CH122-S002 8 Rope clamp stainless steel SKL3-VA
KERZLER
G G
166 168
Date 13.10.2011 2.2040 PARTLIST
Parts list Stacker
Ed. by cw-de +X
Appr. VUNG ANG Page 167
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Quantity
Device tag Designation Type Number Supplier
DITTELBACH &
==00EAC51=CH122-S002 2 Tension Spring stainless steel SPF-W
KERZLER
DITTELBACH &
==00EAC51=CH122-S002 2 Rope tension lock stainless steel SPS6-VA
KERZLER
DITTELBACH &
==00EAC51=CG106-S001 1 Conveyor belt misalignment switch LHPE-10/2-L50V
KERZLER
B B
==00EAC51=CL101-B001 1 Vibrating level switch for granular bulk solids with vibrating rod VIBS61.EXX1RA VEGA
C C
D D
E E
F F
G G
167 ==SUMMPARTLIST+/169
Date 13.10.2011 2.2040 PARTLIST
Parts list Stacker
Ed. by cw-de +X
Appr. VUNG ANG Page 168
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Rotary handle operating mechanism RHE normal for fixed and plug-in T4 - T5 054929 ABB
1SDA054929R1 4
auxiliary contact AUX -C3Q 1SY 24V DC for T4-T5-T6 1SDA054915R1 ABB
1SDA054915R1 4
C
bushing type current transformer MBS ASK31.4 200A/1A 10VA ASK 31.4 MBS GmbH C
8254 3
2-CHANNEL SERIAL BINARY TRANSMISSION FIBRE OPTIC CABLE 820NM 7XV5653-0BA00 SIEMENS
7XV5653-0BA00 2
Component terminal block, Connection method: Screw connection, Width: 8.2 mm, Mounting type: NS 35/7,5, NS 35/15, NS 32, Color: 0313085 Phoenix Contact
E 0313085 12 E
gray
switch-disconnector, 80 A, 3 pole OT80F3 ABB
1SCA105798R1001 1
G G
==PARTLIST+X/168 170
Date 13.10.2011 2.2040 SUMMPARTLIST
Summarized parts list Stacker
Ed. by cw-de +
Appr. VUNG ANG Page 169
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
SITOP POWER 10 STABILIZED POWER SUPPLY 400-500 V AC OUTPUT: 24 V DC/10 A 6EP1434-2BA10 SIEMENS
B 6EP1434-2BA10 2 B
22MM PLASTIC ROUND ACTUATOR: CES KEY-OPER.SWITCH WITH 2 KEYS 2 SWITCH POSITIONS O-I LATCHING LOCK NO SSG 10, 3SB3000-4LD01 SIEMENS
3SB3000-4LD01 1 REMOVAL POS. O WITH HOLDER
ACTUATOR-/INDICATOR COMPONENT CONTACT BLOCK WITH 1 CONTACT ELEMENT SCREW TERMINAL, 1NO 3SB3400-0B SIEMENS
3SB3400-0B 3
C
circuit breaker S 202-M-C 6A 2 pole S202-M-C6 ABB C
S202-M-C6 1
Block Contactors A50-30-22 22 kW 400V 2NO/2NC coil voltage 110V AC A50-30-22 ABB
1SBL351001R8422 1
D D
SIRIUS SAFETY RELAY WITH RELAY RELEASE CIRCUITS (FK) 3TK2827-1AB21 SIEMENS
E 3TK28271AB21 1 E
Block Contactors A9-30-22 4 kW 400V 2NO/2NC coil voltage 110V AC A9-30-22 ABB
1SBL141001R8422 3
Diode suppressor contactor choke RV 5/250 110...250 AC/DC A9...A110 RV 5/250 ABB
1SBN050010R1002 3
F F
ACS800-01, industrial drive, 55 kW, IP21 ACS800-01-0060-3 ABB
ACS800-01-0060-3 1
SIMATIC DP,BUS CONNECTOR FOR PROFIBUS UP TO 12 MBIT/S 90 DEGREE ANGLE CABLE OUTLET, IPCD TECHOLOGY FAST 6ES7972-0BB52-0XA0 SIEMENS
6ES7972-0BB52-0XA0 2 CONNECT, WITH PG SOCKET 15,8 X 59 X 35,6 MM (WXHXD),
circuit breaker S 203-M-C 16A S203-M-C16 ABB
S203-M-C16 6
G G
169 171
Date 13.10.2011 2.2040 SUMMPARTLIST
Summarized parts list Stacker
Ed. by cw-de +
Appr. VUNG ANG Page 170
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Cabinet heating Typ 4 „LM-Long“ 230V 375 W IP 52 internal thermostat TYP4/230V/375W/IP52/THERMOSTATLM Heizungen
TYP4/230V/375W/IP52/THERMOSTAT 1
C
Proportinal valve D1FBB31HC0NMW010 PARKER C
D1FBB31HC0NMW010 1
Sensor/Actuator cable, 3-position, Free conductor end, on Valve plug A, with 1 LED, connected with Varistor, Cable length: 10 m SAC-3P-10,0-PUR/A-1L-V Phoenix Contact
1443132 9
D D
G G
170 172
Date 13.10.2011 2.2040 SUMMPARTLIST
Summarized parts list Stacker
Ed. by cw-de +
Appr. VUNG ANG Page 171
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
COMBI MARITIM 607 Damp proof Junction Boxes 6 mm² COMBI_MAR_607/5 WISKA
COMBI_MAR_607/5 13
C
Dustproof/Waterproof Polyester Light Fitting with Diffuser - Insulation Class II 1x58W 161158AUS SCHUCH C
161000400 13
Dustproof/Waterproof Polyester Light Fitting with Diffuser - Insulation Class IIfor outdoor installation 162 258 AUS SCHUCH
162000400 1
SCHUKO socket-outlet 16 A, AC 250 V, DIN 49440 With labelling option and labelling insert. With plug-in terminals. 238039 MERTEN
E 238039 1 E
G G
171 173
Date 13.10.2011 2.2040 SUMMPARTLIST
Summarized parts list Stacker
Ed. by cw-de +
Appr. VUNG ANG Page 172
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Uninterruptible power supply with integrated power supply unit, 5A, in combination with MINI-BAT/24/DC/1.3 AH, QUINT-BAT/24DC TRIO-UPS/1AC/24DC/ 5 Phoenix Contact
2866611 1 3,4AH, 7,2AH or 12 AH
C
Rechargeable battery module, lead AGM, VRLA technology, 24 V DC, 1.3 Ah. MINI-BAT/24DC/1.3AH Phoenix Contact C
2866417 1
SIMATIC S7-300 CPU 315-2 PN/DP, CENTRAL PROCESSING UNIT WITH 384 KBYTE WORKING MEMORY, 1. INTERFACE MPI/DP 6ES7315-2EH14-0AB0 SIEMENS
6ES7315-2EH14-0AB0 1 12MBIT/S, 2. INTERFACE ETHERNET PROFINET, WITH 2 PORT SWITCH, MICRO MEMORY CARD NECESSARY
SIMATIC S7, MICRO MEMORY CARD P. S7-300/C7/ET 200, 3.3 V NFLASH, 2 MBYTES 6ES7953-8LL20-0AA0 SIEMENS
6ES7953-8LL20-0AA0 1
D D
SIMATIC S7-300, DIGITAL INPUT SM 321, OPTICALLY ISOLATED 32DI, 24 V DC, 1 X 40 PIN 6ES7321-1BL00-0AA0 SIEMENS
6ES7321-1BL00-0AA0 6
SIMATIC S7-300,INTERFACE MODULE IM 365 FOR CONNECTING AN EXPANSION RACK, W/O K-BUS, 2 MODULES + CONNECTING 6ES7365-0BA01-0AA0 SIEMENS
6ES7365-0BA01-0AA0 1 CABLE 1M
SIMATIC S7-300, analog input SM 331 S7 SIEMENS
6ES7331-7KF02-0AB0 1
SIMATIC S7-300, FRONT CONNECTOR FOR SIGNAL MODULES WITH SCREW CONTACTS, 20-PIN 6ES7392-1AJ00-0AA0 SIEMENS
6ES7392-1AJ00-0AA0 2
F F
SIMATIC S7-300, ANALOG OUTPUT SM 332, OPTICALLY ISOLATED, 2 AO, U/I; 11/12 BITS RESOL., 20 PIN., REMOVE/INSERT WITH 6ES7332-5HB01-0AB0 SIEMENS
6ES7332-5HB01-0AB0 1 ACTIVE BACKPLANE BUS
SCALANCE X204-2, MANAGED IE SWITCH, 4 X 10/100MBIT/S RJ45 PORTS 6GK5204-2BB10-2AA3 SIEMENS
6GK5204-2BB10-2AA3 1
G G
172 174
Date 13.10.2011 2.2040 SUMMPARTLIST
Summarized parts list Stacker
Ed. by cw-de +
Appr. VUNG ANG Page 173
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Sounder-Strobe Light-Combination type YL5, 24 VDC, Lens colour amber 25511303 FHF GmbH
25511303 1
SIRIUS POSITION SWITCH PLASTIC HOUSING ACC. TO EN50047, 31MM DEVICE CONNECTION 1X(M20X1.5); 1NO/1NC SLOW-ACTION 3SE5232-0BF10 SIEMENS
3SE5232-0BF10 1 CONTACTS ANGULAR ROLLER PLUNGER W. PLASTIC ROLLER 13MM
Rocker button 10 A, 250 V AC Illuminated. With plug-in terminals as connecting terminals in accordance with VDE 0632. 375975 MERTEN
375975 3
C
Inductive sensor with extended switching distance DC 4-wire, 10…65 VDC Changeover contact, PNP output NI50-CP80-VP4X2 Hans Turck C
NI50-CP80-VP4X2 2 GmbH & Co. KG
Compact transmitters for non-contact level measurement of fluids, pastes and coarse bulk materials FMU42-AMB2A22A Endress+Hauser
FMU42-AMB2A22A 3
ENCLOSURE FOR 22MM PROGRAM PLASTIC VERSION 3 COMMAND POSITIONS GRAY TOP PART 3SB3803-0AA3 SIEMENS
3SB3803-0AA3 3
22MM PLASTIC ROUND ACTUATOR: RONIS LOCK WITH 2 KEYS 2 SWITCH POSITIONS O-I 3SB3000-4HD21 SIEMENS
3SB3000-4HD21 3
D D
COMPONENT FOR ENCLOSURE, 22MM CONTACT BLOCK WITH 1 CONTACT ELEMENT SCREW TERMINAL, 1NO 3SB3420-0B SIEMENS
3SB3420-0B 14
COMPONENT FOR ENCLOSURE, 22MM CONTACT BLOCK WITH 1 CONTACT ELEMENT SCREW TERMINAL, 1NC 3SB3420-0C SIEMENS
3SB3420-0C 4
INSCRIPTION LABEL FOR GLUING ON ENCLOSURE, LABEL SIZE 22 X 22MM, SILVER-COLORED, BLACK LETTERING, LOCK NUMBER 3SB1901-3XZK1YZ1REMOTEZ2LOCAL SIEMENS
3SB1901-3XZK1YZ1REMOTEZ2LOCAL 3
22MM PLASTIC ROUND ACTUATOR: PUSHBUTTON WITH FLAT BUTTON WITH HOLDER GREEN 3SB3000-0AA41 SIEMENS
E 3SB3000-0AA41 5 E
INSCRIPTION LABEL FOR GLUING ON ENCLOSURE, LABEL SIZE 22 X 22MM, SILVER-COLORED, BLACK LETTERING, WITH 3SB1901-3EL SIEMENS
3SB1901-3EL 1 INSCRIPTION: START SILVER-COLORED, BLACK LETTERING
22MM PLASTIC ROUND ACTUATOR: PUSHBUTTON WITH FLAT BUTTON WITH HOLDER RED 3SB3000-0AA21 SIEMENS
3SB3000-0AA21 1
INSCRIPTION LABEL FOR GLUING ON ENCLOSURE, LABEL SIZE 22 X 22MM, SILVER-COLORED, BLACK LETTERING, WITH 3SB1901-3EK SIEMENS
3SB1901-3EK 1 INSCRIPTION: STOP SILVER-COLORED, BLACK LETTERING
F F
SIRIUS SAFETY RELAY WITH RELAY RELEASE CIRCUITS (RC) 3TK2826-1CW30 SIEMENS
3TK28261CW30 1
SIRIUS SAFETY RELAY WITH RELAY RELEASE CIRCUITS (FK) 3TK2830-1CB30 SIEMENS
3TK28301CB30 1
ENCLOSURE FOR 22MM PROGRAM PLASTIC VERSION 1 COMMAND POSITION YELLOW TOP PART WITH PROTECTIVE COLLAR 3SB3801-0EF3 SIEMENS
3SB3801-0EF3 6 A=EMER.-STOP40MM ROT.-TO-UNLAT. 2NC
G G
173 175
Date 13.10.2011 2.2040 SUMMPARTLIST
Summarized parts list Stacker
Ed. by cw-de +
Appr. VUNG ANG Page 174
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
INSCRIPTION LABEL FOR GLUING ON ENCLOSURE, LABEL SIZE 22 X 22MM, SILVER-COLORED, BLACK LETTERING, LOCK NUMBER 3SB1901-3XZK1YFORWARD SIEMENS
3SB1901-3XZK1YFORWARD 1
INSCRIPTION LABEL FOR GLUING ON ENCLOSURE, LABEL SIZE 22 X 22MM, SILVER-COLORED, BLACK LETTERING, LOCK NUMBER 3SB1901-3XZK1YBACKWARD SIEMENS
3SB1901-3XZK1YBACKWARD 1
INSCRIPTION LABEL FOR GLUING ON ENCLOSURE, LABEL SIZE 22 X 22MM, SILVER-COLORED, BLACK LETTERING, LOCK NUMBER 3SB1901-3XZK1YUP SIEMENS
B 3SB1901-3XZK1YUP 1 B
INSCRIPTION LABEL FOR GLUING ON ENCLOSURE, LABEL SIZE 22 X 22MM, SILVER-COLORED, BLACK LETTERING, LOCK NUMBER 3SB1901-3XZK1YDOWN SIEMENS
3SB1901-3XZK1YDOWN 1
ACTUATOR-/INDICATOR COMPONENT CONTACT BLOCK WITH 1 CONTACT ELEMENT SCREW TERMINAL, 1NC 3SB3400-0C SIEMENS
3SB3400-0C 1
C
PROTECTIVE COLLAR YELLOW FOR MUSHR.PUSHBUTTON 3SB3921-0AK SIEMENS C
3SB3921-0AK 1
Position and limit switch 1NO, 1NC snap action MD250-11z SCHMERSAL
MD250-11z 4
Position switch / 335 Metal enclosure - DIN EN 50041 with Actuator / 335 Roller lever 7H (NO/NC) Snap switch element Z4V7H 335-11Z SCHMERSAL
Z4V7H 335-11Z 3
D D
Inductive sensor, Threaded barrel, M30 x 1.5, DC 4-wire, 10…55 VDC, Changeover contact, PNP output BI15U-M30-VP44X Hans Turck
BI15U-M30-VP44X 8 GmbH & Co. KG
Level/temperature display and monitoring 1 switching output, 1 analog output, connector M12 (4 pin), SCLTSD-370-10-07 PARKER
SCLTSD-370-10-07 1
Sensor/actuator connector, female, straight, 5-pos., M12 SPEEDCON, A-coded, screw connection, metal knurl, cable screw connection SACC-FS-5CON-PG 7-M SCO Phoenix Contact
1543032 4 PG 7
DIGITAL PRESSURE SWITCH SCPSD-250-14-25 PARKER
E SCPSD-250-14-25 3 E
G G
174 176
Date 13.10.2011 2.2040 SUMMPARTLIST
Summarized parts list Stacker
Ed. by cw-de +
Appr. VUNG ANG Page 175
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Compact enclosure AE, painted RAL 7032, single door, with mount. plate AE1039.600 Rittal
AE1039.600 1
Compact enclosure AE, painted RAL 7032, with mount. plate, single door AE1060.600 Rittal
B AE1060.600 1 B
C
pluggable interface relay CR-P110AC1, 110V AC (1CO) CR-P110AC1 ABB C
1SVR405600R7000 1
SACE PR212/CI contactor control unit for PR222MP T4-T5 PR212/CI ABB
1SDA050708R1 1
contact for status signal tripping solenoid breaker S51 AUX-SA 1 S51 T4 T5 ABB
1SDA055050R0001 1
D D
block contactor A145 110kW 690V 2NO/2NC coil voltage 110V AC A145-30-22 ABB
1SFL471001R8422 1
Inductive sensor Threaded barrel, M18 x 1 NO contact, Cable connection, DC 2-wire, 10…300 VDC BI5-M18-AZ3X Hans Turck
BI5-M18-AZ3X 1 GmbH & Co. KG
G G
175 177
Date 13.10.2011 2.2040 SUMMPARTLIST
Summarized parts list Stacker
Ed. by cw-de +
Appr. VUNG ANG Page 176
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
COMBI MARITIM 308 Damp proof Junction Boxes 2,5mm² COMBI_MAR_308/5 WISKA
COMBI_MAR_308/5 2
POSITION SWITCH, METAL-ENCLOSED SNAP-ACTION CONTACTS 1NO+1NC, OVERTRAVEL PLUNGER TYPE B, 1 X M20 X 1,5 3SE2120-1C SIEMENS
3SE2120-1C 1
Vibrating level switch for granular bulk solids with vibrating rod VIBS61.EXX1RA VEGA
VIBS61.EXX1RA 1
One-piece console single door painted RAL 7032 600 mm x 960 mm x 400 mm AP2666.600 Rittal
AP2666.600 1
C C
D D
E E
F F
G G
176 ==TERMINAL+F01/178
Date 13.10.2011 2.2040 SUMMPARTLIST
Summarized parts list Stacker
Ed. by cw-de +
Appr. VUNG ANG Page 177
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-1048
Strip
Cable name
Cable name
==00EAD03=AH002+F01-X2
H07 RN-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
-S001 1 1 +F02-7-X2 1 BN &VA1-FLS-00EAD03-E-M2-DWD-0608+/58.1
-S001 5 2 +F02-7-X2 2 BU &VA1-FLS-00EAD03-E-M2-DWD-0608+/58.2
-E001 PE PE +F02-7-X2 PE GNYE &VA1-FLS-00EAD03-E-M2-DWD-0608+/58.1
C C
D D
E E
F F
G G
==SUMMPARTLIST+/177 179
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AH002+F01-X2 + F01
Appr. VUNG ANG Page 178
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAC03=CH102+F01-X3
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
==00EAD03+F03-A001 23 1 =AF001+F01-5-X9 1 &VA1-FLS-00EAD03-E-M2-DWD-0608=AF001/136.7
=AF001+F01-5-X9 2 2 ==00EAD03+F03-A001 24 &VA1-FLS-00EAD03-E-M2-DWD-0608=AF001/136.7
C C
D D
E E
F F
G G
178 +F01-2/180
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAC03=CH102+F01-X3 + F01
Appr. VUNG ANG Page 179
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-1003
Strip
Cable name
Cable name
==00EAD03=AE001+F01-2-X1
H07 RN-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
BN +F03-X1 1 1 -Q003 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/21.1
BK +F03-X1 2 2 -Q003 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/21.1
GY +F03-X1 3 3 -Q003 6 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/21.1
C C
+F03-X1 7 4 -F006 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/25.1
+F03-X1 8 5 -F006 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/25.1
GNYE +F03-X1 PE PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/21.1
D D
E E
F F
G G
+F01/179 181
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AE001+F01-2-X1 + F01-2
Appr. VUNG ANG Page 180
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4018
-4017
-4016
-4015
-4013
Strip
Cable name
Cable name
==00EAD03=AE001+F01-2-X3
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
-Q003 31 1 +F03-A001 Y34 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/26.3
+F03-Q004 32 2 -Q003 32 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/26.3
1 +LC01-X3 1 3 +F03-A001 Y10 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/26.5
C C
2 +LC01-X3 2 4 =CH102+F03-A001 44 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/26.5
1 =CG119+X-S002 21 5 =EH001+F04-K011 11 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/26.5
2 =CG119+X-S002 22 6 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/26.6
1 =CG120+X-S003 21 7 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/26.6
2 =CG120+X-S003 22 8 =EH001+F04-K011 14 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/26.7
1 =CG117+X-S004 21 9 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/26.8
2 =CG117+X-S004 22 10 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/26.8
1 =CG118+X-S005 21 11 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/26.9
D D
2 =CG118+X-S005 22 12 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/26.9
E E
F F
G G
180 182
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AE001+F01-2-X3 + F01-2
Appr. VUNG ANG Page 181
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=AE001+F01-2-X9
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
=CH102+F03-X3 1 1 -F001 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/21.6
-K003 14 2 =CH102+F03-X3 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/21.6
+F03-Q004 A2 5 -T001 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/21.6
C C
-Q003 A2
D D
E E
F F
G G
181 183
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AE001+F01-2-X9 + F01-2
Appr. VUNG ANG Page 182
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=AE001+F01-2-X10
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
=EH001+F04-X10 65+ 1 -Q001 14 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/81.5
=EH001+F04-X10 66+ 2 -Q002 13 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/81.6
=EH001+F04-X10 67+ 3 -F001 13 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/81.7
C C
=EH001+F04-X10 68+ 4 -Q003 13 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/81.7
-Q001 11 5 =EH001+F04-X10 65 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/81.5
-Q002 14 6 =EH001+F04-X10 66 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/81.6
-F001 14 7 =EH001+F04-X10 67 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/81.7
-Q003 14 8 =EH001+F04-X10 68 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/81.7
D D
E E
F F
G G
182 184
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AE001+F01-2-X10 + F01-2
Appr. VUNG ANG Page 183
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=AE001+F01-2-X20
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
=EH001+F04-X20 4 1 -K003 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/101.4
-K003 A2 2 =EH001+F04-X20 12 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/101.4
C C
D D
E E
F F
G G
183 +F01-4/185
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AE001+F01-2-X20 + F01-2
Appr. VUNG ANG Page 184
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-1001
-1002
Strip
Cable name
Cable name
==00EAD03=GU001+F01-4-X1
H07 RN-F
H07 RN-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
BN +X-T001 1U 1 -Q001 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/18.2
BK +X-T001 1V 2 -Q001 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/18.2
GY +X-T001 1W 3 -Q001 6 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/18.3
C C
+F01-3-Q002 6 4 +X-T001 2W BN &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/18.2
+F01-3-Q002 4 5 +X-T001 2U BK &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/18.2
+F01-3-Q002 2 6 +X-T001 2V GY &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/18.3
=AE002+F02-X2 2 7 +X-T001 2N BL &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/18.3
GNYE +X-T001 PE PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/18.3
-PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/18.3
D D
E E
F F
G G
+F01-2/184 186
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=GU001+F01-4-X1 + F01-4
Appr. VUNG ANG Page 185
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4046
Strip
Cable name
Cable name
==00EAD03=GU001+F01-4-X10
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
-Q001 14 1 =EH001+F04-X10 21+ 1 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/77.2
-Q001 11 2 =EH001+F04-X10 21 2 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/77.1
+F01-3-Q002 13 3 =EH001+F04-X10 36+ &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/78.6
C C
=EH001+F04-X10 36 4 +F01-3-Q002 14 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/78.6
D D
E E
F F
G G
185 +F01-5/187
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=GU001+F01-4-X10 + F01-4
Appr. VUNG ANG Page 186
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-1054
Strip
Cable name
Cable name
==00EAC03=AF001+F01-5-X1
H07 RN-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
BN +X-M001 U 1 -Q003 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/136.1
BK +X-M001 V 2 -Q003 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/136.1
GY +X-M001 W 3 -Q003 6 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/136.1
C C
GNYE +X-M001 PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/136.1
D D
E E
F F
G G
+F01-4/186 188
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAC03=AF001+F01-5-X1 + F01-5
Appr. VUNG ANG Page 187
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAC03=AF001+F01-5-X3
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
-Q003 21 1 ==00EAD03=CH102+F03-X3 1 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=CH102+/107.2
2 -Q003 22 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=CH102+/107.2
+F02-Q006 21 3 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=CH102+/107.2
C C
==00EAD03=CH102+F03-X3 2 4 +F02-Q006 22 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=CH102+/107.2
D D
E E
F F
G G
187 189
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAC03=AF001+F01-5-X3 + F01-5
Appr. VUNG ANG Page 188
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAC03=AF001+F01-5-X5
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
+X-M001 1 -Q001-X4 3 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/136.2
+X-M001 PE 2 -Q001-X4 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/136.2
C C
D D
E E
F F
G G
188 190
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAC03=AF001+F01-5-X5 + F01-5
Appr. VUNG ANG Page 189
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-1055
Strip
Cable name
Cable name
==00EAC03=AF001+F01-5-X9
H07 RN-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
=CH102+F01-X3 1 1 -B001 1 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/136.7
2 =CH102+F01-X3 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/136.7
BN +X-M001 1 3 -K002 11 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/137.1
C C
BU +X-M001 2 4 -B001 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/137.1
GNYE +X-M001 PE PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/137.1
D D
E E
F F
G G
189 191
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAC03=AF001+F01-5-X9 + F01-5
Appr. VUNG ANG Page 190
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
==00EAD03-4043
Strip
Cable name
Cable name
==00EAC03=AF001+F01-5-X10
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
1 ==00EAD03=EH001+F04-X10 2+ 2 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/75.2
2 ==00EAD03=EH001+F04-X10 2 1 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/75.2
3 ==00EAD03=EH001+F04-X10 3 3 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/75.3
C C
-K100 98 4 ==00EAD03=EH001+F04-X10 4 4 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/75.4
-Q002 14 5 ==00EAD03=EH001+F04-X10 5 5 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/75.5
-F001 14 6 ==00EAD03=EH001+F04-X10 6 6 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/75.6
-K003 11 7 ==00EAD03=EH001+F04-X10 7 7 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/75.7
-Q003 14 8 ==00EAD03=EH001+F04-X10 8 8 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/75.7
D D
E E
F F
G G
190 192
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAC03=AF001+F01-5-X10 + F01-5
Appr. VUNG ANG Page 191
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAC03=AF001+F01-5-X20
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
==00EAD03=EH001+F04-X20 1 1 -K000 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/101.1
-K000 A2 2 ==00EAD03=EH001+F04-X20 9 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/101.1
==00EAD03=EH001+F04-X20 3 3 -K002 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/101.3
C C
-K002 A2 4 ==00EAD03=EH001+F04-X20 11 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/101.3
D D
E E
F F
G G
191 +F01-6/193
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAC03=AF001+F01-5-X20 + F01-5
Appr. VUNG ANG Page 192
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-1000
Strip
Cable name
Cable name
==00EAD03=GS001+F01-6-X1
H07 RN-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
BN +W000-X1 L1 1 -Q000 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/16.0
BK +W000-X1 L2 2 -Q000 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/16.1
GY +W000-X1 L3 3 -Q000 6 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/16.1
C C
GNYE +W000-X1 PE PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/16.1
D D
E E
F F
G G
+F01-5/192 194
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=GS001+F01-6-X1 + F01-6
Appr. VUNG ANG Page 193
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4042
-4042
Strip
Cable name
Cable name
==00EAD03=GS001+F01-6-X10
H05VV5-F
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
-Q000 14 1 =EH001+F04-X10 1+ 1 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/75.2
2 =EH001+F04-X10 1 2 -Q000 11 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/75.1
C C
D D
E E
F F
G G
193 195
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=GS001+F01-6-X10 + F01-6
Appr. VUNG ANG Page 194
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-1015
-1016
Strip
Cable name
Cable name
==00EAD03=GU002+F01-6-X1
H07 RN-F
H07 RN-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
BN +LC01-X1 1 1 -Q001 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+/47.2
BK +LC01-X1 2 2 -Q001 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+/47.2
GY +LC01-X1 3 3 -Q001 6 &VA1-FLS-00EAD03-E-M2-DWD-0608+/47.3
C C
=GS002+F02-7-Q001 9 4 +LC01-X1 4 BN &VA1-FLS-00EAD03-E-M2-DWD-0608+/47.2
=GS002+F02-7-F001 5 5 +LC01-X1 5 BK &VA1-FLS-00EAD03-E-M2-DWD-0608+/47.2
=GS002+F02-7-F001 3 6 +LC01-X1 6 GY &VA1-FLS-00EAD03-E-M2-DWD-0608+/47.3
=GS002+F02-7-F001 1 7 +LC01-X1 7 BL &VA1-FLS-00EAD03-E-M2-DWD-0608+/47.3
GNYE +LC01-X1 PE PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608+/47.3
PE +LC01-X1 PE GNYE &VA1-FLS-00EAD03-E-M2-DWD-0608+/47.3
D D
E E
F F
G G
194 +F02/196
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=GU002+F01-6-X1 + F01-6
Appr. VUNG ANG Page 195
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-1009
-4054
Strip
Cable name
Cable name
==00EAD03=AE002+F02-X1
H07 RN-F
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
3 =EH001+F04-X10 81 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/83.1
=EH001+F04-X10 81+ 4 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/83.1
=EH001+F04-X10 85 5 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/83.5
C C
8 =EH001+F04-X10 85+ &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/83.5
9 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/83.5
=CH102+F03-X3 7 11 &VA1-FLS-00EAD03-E-M2-DWD-0608=CH102+/107.5
12 =CH102+F03-X3 4 &VA1-FLS-00EAD03-E-M2-DWD-0608=CH102+/107.5
13 =EH001+F04-X10 84 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/83.4
=EH001+F04-X10 84+ 14 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/83.4
1 +X-M001 15 &VA1-FLS-00EAD03-E-M2-DWD-0608/28.3
2 +X-M001 PE 16 &VA1-FLS-00EAD03-E-M2-DWD-0608/28.3
D D
GNYE +X-M001 PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608/28.2
BN +X-M001 U U1 &VA1-FLS-00EAD03-E-M2-DWD-0608/28.1
BK +X-M001 V V1 &VA1-FLS-00EAD03-E-M2-DWD-0608/28.2
GY +X-M001 W W1 &VA1-FLS-00EAD03-E-M2-DWD-0608/28.2
E E
F F
G G
+F01-6/195 197
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AE002+F02-X1 + F02
Appr. VUNG ANG Page 196
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-1010
Strip
Cable name
Cable name
==00EAD03=AE002+F02-X2
H07 RN-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
BN -E001 1 +F02-7-F002 2 &VA1-FLS-00EAD03-E-M2-DWD-0608/30.1
BU -E001 2 =GU001+F01-4-X1 7 &VA1-FLS-00EAD03-E-M2-DWD-0608/30.2
=AE004+F02-7-X2 2
C C
GNYE -E001 PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608/30.2
D D
E E
F F
G G
196 198
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AE002+F02-X2 + F02
Appr. VUNG ANG Page 197
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=AE002+F02-X10
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
=EH001+F04-X10 82+ 1 +F02-7-Q002 13 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/83.2
+F02-7-Q002 14 2 =EH001+F04-X10 82 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/83.2
=EH001+F04-X10 83+ 3 +F02-7-F001 13 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/83.3
C C
+F02-7-F001 14 4 =EH001+F04-X10 83 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/83.3
D D
E E
F F
G G
197 199
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AE002+F02-X10 + F02
Appr. VUNG ANG Page 198
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-1011
Strip
Cable name
Cable name
==00EAD03=AP010+F02-X1
H07 RN-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
3 =EH001+F04-X10 121 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/87.1
=EH001+F04-X10 121+ 4 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/87.1
=CH102+F03-X3 8 11 &VA1-FLS-00EAD03-E-M2-DWD-0608=CH102+/107.5
C C
12 =CH102+F03-X3 7 &VA1-FLS-00EAD03-E-M2-DWD-0608=CH102+/107.5
13 =EH001+F04-X10 124 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/87.4
=EH001+F04-X10 124+ 14 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/87.4
GNYE -M001 PE PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608/37.2
U1 &VA1-FLS-00EAD03-E-M2-DWD-0608/37.1
V1 &VA1-FLS-00EAD03-E-M2-DWD-0608/37.2
W1 &VA1-FLS-00EAD03-E-M2-DWD-0608/37.2
D D
E E
F F
G G
198 200
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AP010+F02-X1 + F02
Appr. VUNG ANG Page 199
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=AP010+F02-X10
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
=EH001+F04-X10 122+ 1 +F02-7-Q002 13 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/87.2
+F02-7-Q002 14 2 =EH001+F04-X10 122 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/87.2
=EH001+F04-X10 123+ 3 +F02-7-F001 13 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/87.3
C C
+F02-7-F001 14 4 =EH001+F04-X10 123 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/87.3
D D
E E
F F
G G
199 201
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AP010+F02-X10 + F02
Appr. VUNG ANG Page 200
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-1012
Strip
Cable name
Cable name
==00EAD03=AP020+F02-X1
H07 RN-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
3 =EH001+F04-X10 125 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/87.5
=EH001+F04-X10 125+ 4 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/87.5
=CH102+F03-X3 9 11 &VA1-FLS-00EAD03-E-M2-DWD-0608=CH102+/107.5
C C
12 =CH102+F03-X3 8 &VA1-FLS-00EAD03-E-M2-DWD-0608=CH102+/107.5
13 =EH001+F04-X10 128 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/87.7
=EH001+F04-X10 128+ 14 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/87.7
GNYE -M001 PE PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608/40.2
BN -M001 U U1 &VA1-FLS-00EAD03-E-M2-DWD-0608/40.1
BK -M001 V V1 &VA1-FLS-00EAD03-E-M2-DWD-0608/40.2
GY -M001 W W1 &VA1-FLS-00EAD03-E-M2-DWD-0608/40.2
D D
E E
F F
G G
200 202
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AP020+F02-X1 + F02
Appr. VUNG ANG Page 201
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=AP020+F02-X10
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
=EH001+F04-X10 126+ 1 +F02-7-Q002 13 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/87.6
+F02-7-Q002 14 2 =EH001+F04-X10 126 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/87.6
=EH001+F04-X10 127+ 3 +F02-7-F001 13 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/87.7
C C
+F02-7-F001 14 4 =EH001+F04-X10 127 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/87.7
D D
E E
F F
G G
201 203
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AP020+F02-X10 + F02
Appr. VUNG ANG Page 202
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-1013
-4055
Strip
Cable name
Cable name
==00EAD03=AE004+F02-X1
H07 RN-F
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
3 =EH001+F04-X10 141 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/89.1
=EH001+F04-X10 141+ 4 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/89.1
=EH001+F04-X10 167 5 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/91.7
C C
8 =EH001+F04-X10 167+ &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/91.7
9 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/91.7
=CH102+F03-X3 4 11 &VA1-FLS-00EAD03-E-M2-DWD-0608=CH102+/107.2
12 =CH102+F03-X3 3 &VA1-FLS-00EAD03-E-M2-DWD-0608=CH102+/107.2
13 =EH001+F04-X10 144 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/89.4
=EH001+F04-X10 144+ 14 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/89.4
1 +X-M001 15 &VA1-FLS-00EAD03-E-M2-DWD-0608/43.3
2 +X-M001 PE 16 &VA1-FLS-00EAD03-E-M2-DWD-0608/43.3
D D
GNYE +X-M001 PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608/43.2
BN +X-M001 U U1 &VA1-FLS-00EAD03-E-M2-DWD-0608/43.1
BK +X-M001 V V1 &VA1-FLS-00EAD03-E-M2-DWD-0608/43.2
GY +X-M001 W W1 &VA1-FLS-00EAD03-E-M2-DWD-0608/43.2
E E
F F
G G
202 204
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AE004+F02-X1 + F02
Appr. VUNG ANG Page 203
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=AE004+F02-X10
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
=EH001+F04-X10 142+ 1 +F02-7-Q002 13 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/89.2
+F02-7-Q002 14 2 =EH001+F04-X10 142 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/89.2
=EH001+F04-X10 143+ 3 +F02-7-F001 13 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/89.3
C C
+F02-7-F001 14 4 =EH001+F04-X10 143 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/89.3
=EH001+F04-X10 145+ 5 +F02-7-F002 13 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/89.5
+F02-7-F002 14 6 =EH001+F04-X10 145 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/89.5
D D
E E
F F
G G
203 205
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AE004+F02-X10 + F02
Appr. VUNG ANG Page 204
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-1056
==00EAD03-4044
Strip
Cable name
Cable name
==00EAC03=AF001+F02-X1
H07 RN-F
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
3 ==00EAD03=EH001+F04-X10 11 1 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/76.1
4 ==00EAD03=EH001+F04-X10 11+ 2 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/76.1
13 ==00EAD03=EH001+F04-X10 14 5 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/76.4
C C
==00EAD03=EH001+F04-X10 14+ 14 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/76.4
GNYE -M002 PE PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608/138.2
BN -M002 U U1 &VA1-FLS-00EAD03-E-M2-DWD-0608/138.1
BK -M002 V V1 &VA1-FLS-00EAD03-E-M2-DWD-0608/138.2
GY -M002 W W1 &VA1-FLS-00EAD03-E-M2-DWD-0608/138.2
D D
E E
F F
G G
204 206
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAC03=AF001+F02-X1 + F02
Appr. VUNG ANG Page 205
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAC03=AF001+F02-X9
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
=CH102-X3 3 3 +F02-7-F002 2 &VA1-FLS-00EAD03-E-M2-DWD-0608/139.1
4 +F02-7-T003 4 &VA1-FLS-00EAD03-E-M2-DWD-0608/139.2
C C
D D
E E
F F
G G
205 207
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAC03=AF001+F02-X9 + F02
Appr. VUNG ANG Page 206
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
==00EAD03-4044
Strip
Cable name
Cable name
==00EAC03=AF001+F02-X10
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
==00EAD03=EH001+F04-X10 12+ 1 +F02-7-Q005 13 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/76.2
+F02-7-Q005 14 2 ==00EAD03=EH001+F04-X10 12 3 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/76.2
==00EAD03=EH001+F04-X10 13+ 3 +F02-7-F002 13 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/76.3
C C
+F02-7-F002 14 4 ==00EAD03=EH001+F04-X10 13 4 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/76.3
D D
E E
F F
G G
206 208
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAC03=AF001+F02-X10 + F02
Appr. VUNG ANG Page 207
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAC03=CH102+F02-X3
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
==00EAD03+F03-A001 33 3 =AF001-X9 3 &VA1-FLS-00EAD03-E-M2-DWD-0608=AF001/139.1
=AF001+F04-K001 14 4 ==00EAD03+F03-A001 34 &VA1-FLS-00EAD03-E-M2-DWD-0608=AF001/139.1
C C
D D
E E
F F
G G
207 +F02-7/209
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAC03=CH102+F02-X3 + F02
Appr. VUNG ANG Page 208
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=GR002+F02-7-X4
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
=CH102+F03-A002 33 1 -F001 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/20.0
=AE002+F04-U1 1 2 -XT001 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/20.1
=CH102+F03-A002 43 3 -F002 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/20.1
C C
=AE002+F04-X4 19 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/20.2
=EH001+F04-K033 13 5 -F003 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/20.2
=AP010+F04-X4 2 6 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/20.3
7 -F004 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/20.4
8 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/20.4
9 -F005 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/20.5
10 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/20.5
D D
E E
F F
G G
+F02/208 210
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=GR002+F02-7-X4 + F02-7
Appr. VUNG ANG Page 209
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=AP010+F02-7-X9
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
+F04-K005 14 1 -F001 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/38.1
2 -T002 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/38.2
C C
D D
E E
F F
G G
209 211
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AP010+F02-7-X9 + F02-7
Appr. VUNG ANG Page 210
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=AP020+F02-7-X9
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
+F04-K006 14 1 -F001 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/41.1
2 -T002 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/41.2
C C
D D
E E
F F
G G
210 212
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AP020+F02-7-X9 + F02-7
Appr. VUNG ANG Page 211
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-1014
Strip
Cable name
Cable name
==00EAD03=AE004+F02-7-X2
H07 RN-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
1 -F002 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/45.2
2 =AE002+F02-X2 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/45.2
=GQ001-X1 4
C C
GNYE +X-E001 PE PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/45.2
D D
E E
F F
G G
211 213
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AE004+F02-7-X2 + F02-7
Appr. VUNG ANG Page 212
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=AE004+F02-7-X9
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
=CH102+F03-X3 5 1 -F001 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/44.1
2 -T002 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/44.2
C C
D D
E E
F F
G G
212 214
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AE004+F02-7-X9 + F02-7
Appr. VUNG ANG Page 213
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=GQ001+F02-7-X1
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
1 -F01 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+/46.1
2 -F01 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+/46.2
3 -F01 6 &VA1-FLS-00EAD03-E-M2-DWD-0608+/46.2
C C
4 =AE004-X2 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+/46.2
PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608+/46.2
D D
E E
F F
G G
213 215
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=GQ001+F02-7-X1 + F02-7
Appr. VUNG ANG Page 214
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=GR001+F02-7-X1
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
+F04-X1 1 1 -Q001 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/49.1
+F04-X1 2 2 -Q001 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/49.2
+F04-X1 3 3 -Q001 6 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/49.2
C C
D D
E E
F F
G G
214 216
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=GR001+F02-7-X1 + F02-7
Appr. VUNG ANG Page 215
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=GP001+F02-7-X1
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
1 -Q002 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/52.1
2 -Q002 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/52.2
2 -Q002 6 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/52.2
C C
2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/52.3
3 =GS002-Q001 10 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/52.2
4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/52.3
5 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/52.3
6 -X2 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/52.3
PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/52.2
PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/52.4
D D
E E
F F
G G
215 217
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=GP001+F02-7-X1 + F02-7
Appr. VUNG ANG Page 216
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-1020
-1019
Strip
Cable name
Cable name
==00EAD03=GP001+F02-7-X2
H07 RN-F
H07 RN-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
BN +X-E27 1 -Q003 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/53.1
BU +X-E27 2 -X1 6 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/53.2
BN +X-X01 1 3 -F003 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/53.4
C C
BU +X-X01 2 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/53.4
5 -F004 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/53.7
6 =AH001-X1 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/53.7
GNYE +X-E27 PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/53.2
GNYE +X-X01 PE PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/53.4
PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/53.7
D D
E E
F F
G G
216 218
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=GP001+F02-7-X2 + F02-7
Appr. VUNG ANG Page 217
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=GP001+F02-7-X20
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
=EH001+F04-X20 55 1 -K030 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/104.1
-K030 A2 2 =EH001+F04-X20 63 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/104.1
=EH001+F04-X20 56 3 -K031 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/104.2
C C
-K031 A2 4 =EH001+F04-X20 64 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/104.2
D D
E E
F F
G G
217 219
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=GP001+F02-7-X20 + F02-7
Appr. VUNG ANG Page 218
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=AH001+F02-7-X1
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
1 -F01 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/57.4
2 -F01 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/57.4
3 -F01 6 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/57.4
C C
4 =GP001-X2 6 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/57.4
=AH002-X2 2
PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/57.4
D D
E E
F F
G G
218 220
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AH001+F02-7-X1 + F02-7
Appr. VUNG ANG Page 219
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-1050
-1049
-1048
Strip
Cable name
Cable name
==00EAD03=AH002+F02-7-X2
H07 RN-F
H07 RN-F
H07 RN-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
BN +F01-X2 1 1 -F001 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+/58.1
BU +F01-X2 2 2 =AH001-X1 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+/58.2
+F02-S002 1 3 -F002 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+/58.3
C C
+F02-S002 5 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+/58.4
BN +F03-X2 1 5 -F003 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+/58.5
BU +F03-X2 2 6 &VA1-FLS-00EAD03-E-M2-DWD-0608+/58.5
BN +F04-X2 1 7 -F004 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+/58.7
BU +F04-X2 2 8 =AH003+F01-S001 5 &VA1-FLS-00EAD03-E-M2-DWD-0608+/58.7
GNYE +F01-X2 PE PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608+/58.1
+F02-E002 PE PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608+/58.3
GNYE +F03-X2 PE PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608+/58.5
D D
GNYE +F04-X2 PE PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608+/58.7
E E
F F
G G
219 221
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AH002+F02-7-X2 + F02-7
Appr. VUNG ANG Page 220
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-1052
-1051
Strip
Cable name
Cable name
==00EAD03=AH003+F02-7-X2
H07 RN-F
H07 RN-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
BN +F03-M01 1 1 +F01-S001 3 &VA1-FLS-00EAD03-E-M2-DWD-0608+/59.2
BU +F03-M01 2 2 +F01-S001 5 &VA1-FLS-00EAD03-E-M2-DWD-0608+/59.2
BN +LC01-X2 1 5 -F002 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+/59.4
C C
BU +LC01-X2 2 6 +F01-S001 5 &VA1-FLS-00EAD03-E-M2-DWD-0608+/59.5
+F03-E01 7 -F003 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+/59.7
+F03-E01 8 =EH001-Q001 3 &VA1-FLS-00EAD03-E-M2-DWD-0608+/59.7
GNYE +F03-M01 PE PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608+/59.2
GNYE +LC01-X2 PE PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608+/59.5
+F03-E01 PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608+/59.7
D D
E E
F F
G G
220 222
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AH003+F02-7-X2 + F02-7
Appr. VUNG ANG Page 221
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4041
Strip
Cable name
Cable name
==00EAD03=EH001+F02-7-X4
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
1 +LC01-X4 1 1 -F001 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/62.3
2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/62.3
+F04-A200 L1+ 3 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/62.3
C C
4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/62.4
2 +LC01-X4 2 5 -G001 M &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/62.4
6 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/62.4
+F04-A200 M1 7 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/62.4
3 +LC01-X4 4 8 -K100 11 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/62.5
4 +LC01-X4 3 9 -K100 14 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/62.6
-K100 24 10 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/98.8
+F04-X10 238 11 -K100 21 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/98.7
D D
GNYE +LC01-X4 PE PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/62.5
-X4 PE
PE -X4 PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/62.5
-X4 PE
PE -X4 PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/62.5
E E
F F
G G
221 +F03/223
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+F02-7-X4 + F02-7
Appr. VUNG ANG Page 222
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-1004
-1003
Strip
Cable name
Cable name
==00EAD03=AE001+F03-X1
H07 RN-F
H07 RN-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
-T002 U1 1 +F01-2-X1 1 BN &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/21.1
-T002 V1 2 +F01-2-X1 2 BK &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/21.1
-T002 W1 3 +F01-2-X1 3 GY &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/21.1
C C
BN +A010-X1 1 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/22.0
BK +A010-X1 2 5 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/22.1
GY +A010-X1 3 6 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/22.1
-Q004 1 7 +F01-2-X1 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/25.1
-Q004 3 8 +F01-2-X1 5 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/25.1
-T002 PE PE +F01-2-X1 PE GNYE &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/21.1
GNYE +A010-X1 PE PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/22.1
D D
E E
F F
G G
+F02-7/222 224
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AE001+F03-X1 + F03
Appr. VUNG ANG Page 223
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4002
Strip
Cable name
Cable name
==00EAD03=AE001+F03-X5
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
1 +A010-X5 1 1 =CT111-K001 -T2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/23.1
2 +A010-X5 2 2 =CT111-K001 -T1 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/23.2
3 +A010-X5 3 3 =CT112-K002 -T2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/23.6
C C
4 +A010-X5 4 4 =CT112-K002 -T1 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/23.6
5 +A010-X5 5 5 =CT113-K003 -T2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/24.1
6 +A010-X5 6 6 =CT113-K003 -T1 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/24.2
7 +A010-X5 7 7 =CT114-K004 -T2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/24.6
8 +A010-X5 8 8 =CT114-K004 -T1 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/24.6
D D
E E
F F
G G
223 225
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AE001+F03-X5 + F03
Appr. VUNG ANG Page 224
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4007
Strip
Cable name
Cable name
==00EAD03=AE001+F03-X6
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
1 +A010-X6 1 1 -Q004 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/25.1
2 +A010-X6 2 2 -Q004 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/25.1
3 +A010-X6 3 3 -Q004 6 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/25.1
C C
4 +A010-X6 4 4 -Q004 5 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/25.2
GNYE +A010-X6 PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/25.2
D D
E E
F F
G G
224 226
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AE001+F03-X6 + F03
Appr. VUNG ANG Page 225
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-1049
Strip
Cable name
Cable name
==00EAD03=AH002+F03-X2
H07 RN-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
-S003 1 1 +F02-7-X2 5 BN &VA1-FLS-00EAD03-E-M2-DWD-0608+/58.5
-S003 5 2 +F02-7-X2 6 BU &VA1-FLS-00EAD03-E-M2-DWD-0608+/58.5
-E003 PE PE +F02-7-X2 PE GNYE &VA1-FLS-00EAD03-E-M2-DWD-0608+/58.5
C C
D D
E E
F F
G G
225 227
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AH002+F03-X2 + F03
Appr. VUNG ANG Page 226
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4064
-4063
-4062
-4061
-4060
-4059
Strip
Cable name
Cable name
==00EAD03=CH102+F03-X3
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
=AE001-A001 43 1 =AE001+F01-2-X9 1 &VA1-FLS-00EAD03-E-M2-DWD-0608=AE001+F01/21.6
==00EAC03=AF001+F01-5-X3 1 1 -A001 Y34 &VA1-FLS-00EAD03-E-M2-DWD-0608+/107.2
=AE001+F01-2-X9 2 2 =AE001-A001 44 &VA1-FLS-00EAD03-E-M2-DWD-0608=AE001+F01/21.6
C C
2 ==00EAC03=AF001+F01-5-X3 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+/107.2
-A002 13 3 =AE002+F02-7-F001 2 &VA1-FLS-00EAD03-E-M2-DWD-0608=AE002+F02/29.1
=AE004+F02-X1 12 3 &VA1-FLS-00EAD03-E-M2-DWD-0608+/107.2
=AE002+F04-K004 14 4 -A002 14 &VA1-FLS-00EAD03-E-M2-DWD-0608=AE002+F02/29.1
=AE002+F02-X1 12 4 =AE004+F02-X1 11 &VA1-FLS-00EAD03-E-M2-DWD-0608+/107.5
-A002 23 5 =AE004+F02-7-X9 1 &VA1-FLS-00EAD03-E-M2-DWD-0608=AE004+F02/44.1
4 +X-S001 12 5 &VA1-FLS-00EAD03-E-M2-DWD-0608+/108.2
=AE004+F04-K007 14 6 -A002 24 &VA1-FLS-00EAD03-E-M2-DWD-0608=AE004+F02/44.1
D D
5 +X-S001 21 6 -A001 Y12 &VA1-FLS-00EAD03-E-M2-DWD-0608+/108.2
=AP010+F02-X1 12 7 =AE002+F02-X1 11 &VA1-FLS-00EAD03-E-M2-DWD-0608+/107.5
=AP020+F02-X1 12 8 =AP010+F02-X1 11 &VA1-FLS-00EAD03-E-M2-DWD-0608+/107.5
-A001 T2 9 =AP020+F02-X1 11 &VA1-FLS-00EAD03-E-M2-DWD-0608+/107.5
3 +X-S001 11 10 -A001 Y22 &VA1-FLS-00EAD03-E-M2-DWD-0608+/108.2
6 +X-S001 22 11 &VA1-FLS-00EAD03-E-M2-DWD-0608+/108.2
3 =CH112+X-S002 11 12 &VA1-FLS-00EAD03-E-M2-DWD-0608+/108.3
4 =CH112+X-S002 12 13 &VA1-FLS-00EAD03-E-M2-DWD-0608+/108.4
E E
5 =CH112+X-S002 21 14 &VA1-FLS-00EAD03-E-M2-DWD-0608+/108.4
6 =CH112+X-S002 22 15 &VA1-FLS-00EAD03-E-M2-DWD-0608+/108.4
3 =CH113+X-S003 11 16 &VA1-FLS-00EAD03-E-M2-DWD-0608+/108.5
4 =CH113+X-S003 12 17 &VA1-FLS-00EAD03-E-M2-DWD-0608+/108.5
5 =CH113+X-S003 21 18 &VA1-FLS-00EAD03-E-M2-DWD-0608+/108.5
6 =CH113+X-S003 22 19 &VA1-FLS-00EAD03-E-M2-DWD-0608+/108.6
3 =CH114+X-S004 11 20 &VA1-FLS-00EAD03-E-M2-DWD-0608+/108.7
4 =CH114+X-S004 12 21 &VA1-FLS-00EAD03-E-M2-DWD-0608+/108.7
F F
5 =CH114+X-S004 21 22 &VA1-FLS-00EAD03-E-M2-DWD-0608+/108.7
6 =CH114+X-S004 22 23 &VA1-FLS-00EAD03-E-M2-DWD-0608+/108.7
3 =CH115+X-S005 11 24 &VA1-FLS-00EAD03-E-M2-DWD-0608+/109.1
4 =CH115+X-S005 12 25 &VA1-FLS-00EAD03-E-M2-DWD-0608+/109.1
5 =CH115+X-S005 21 26 &VA1-FLS-00EAD03-E-M2-DWD-0608+/109.1
6 =CH115+X-S005 22 27 &VA1-FLS-00EAD03-E-M2-DWD-0608+/109.2
3 =CH122+X-S006 11 28 &VA1-FLS-00EAD03-E-M2-DWD-0608+/109.3
4 =CH122+X-S006 12 29 &VA1-FLS-00EAD03-E-M2-DWD-0608+/109.3
G G
226 228
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=CH102+F03-X3 + F03
Appr. VUNG ANG Page 227
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4067
-4066
-4065
-4064
Strip
Cable name
Cable name
==00EAD03=CH102+F03-X3
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
5 =CH122+X-S006 21 30 &VA1-FLS-00EAD03-E-M2-DWD-0608+/109.3
6 =CH122+X-S006 22 31 &VA1-FLS-00EAD03-E-M2-DWD-0608+/109.3
3 +LC01-X3 1 32 &VA1-FLS-00EAD03-E-M2-DWD-0608+/109.4
C C
4 +LC01-X3 2 33 &VA1-FLS-00EAD03-E-M2-DWD-0608+/109.5
5 +LC01-X3 3 34 &VA1-FLS-00EAD03-E-M2-DWD-0608+/109.5
6 +LC01-X3 4 35 &VA1-FLS-00EAD03-E-M2-DWD-0608+/109.5
3 ==00EAC03=CH111+X-S001 11 36 &VA1-FLS-00EAD03-E-M2-DWD-0608+/109.6
4 ==00EAC03=CH111+X-S001 12 37 &VA1-FLS-00EAD03-E-M2-DWD-0608+/109.6
5 ==00EAC03=CH111+X-S001 21 38 &VA1-FLS-00EAD03-E-M2-DWD-0608+/109.6
6 ==00EAC03=CH111+X-S001 22 39 &VA1-FLS-00EAD03-E-M2-DWD-0608+/109.7
3 ==00EAC03=CH112+X-S002 11 40 &VA1-FLS-00EAD03-E-M2-DWD-0608+/109.8
D D
4 ==00EAC03=CH112+X-S002 12 41 &VA1-FLS-00EAD03-E-M2-DWD-0608+/109.8
5 ==00EAC03=CH112+X-S002 21 42 &VA1-FLS-00EAD03-E-M2-DWD-0608+/109.8
6 ==00EAC03=CH112+X-S002 22 43 =EH001+F04-K010 14 &VA1-FLS-00EAD03-E-M2-DWD-0608+/109.8
E E
F F
G G
227 +F04/229
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=CH102+F03-X3 + F03
Appr. VUNG ANG Page 228
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4019
Strip
Cable name
Cable name
==00EAD03=AE001+F04-X4
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
1 =CG001+X-G01 + 1 =GR001-X4 7 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/27.2
2 =CG001+X-G01 - 2 =GR001-X4 8 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/27.3
GNYE =CG001+X-G01 PE PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/27.3
C C
D D
E E
F F
G G
+F03/228 230
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AE001+F04-X4 + F04
Appr. VUNG ANG Page 229
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4038
-4030
-4029
-4021
-4024
Strip
Cable name
Cable name
==00EAD03=AE002+F04-X4
H05VV5-F
H05VV5-F
H05VV5-F
H05VVC4V5-K
H05VVC4V5-K
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
1 +A009-X4 1 1 -U1 9 &VA1-FLS-00EAD03-E-M2-DWD-0608/31.3
2 +A009-X4 2 2 -U1 10 &VA1-FLS-00EAD03-E-M2-DWD-0608/31.4
3 +A009-X4 3 3 -U1 11 &VA1-FLS-00EAD03-E-M2-DWD-0608/31.5
C C
4 +A009-X4 4 4 -U1 12 &VA1-FLS-00EAD03-E-M2-DWD-0608/31.5
=GR001-X4 34 5 +A009-X4 5 1 &VA1-FLS-00EAD03-E-M2-DWD-0608/32.0
+F03-KH002 A1 6 +A009-X4 6 2 &VA1-FLS-00EAD03-E-M2-DWD-0608/32.1
+F03-KH003 A1 7 +A009-X4 7 3 &VA1-FLS-00EAD03-E-M2-DWD-0608/32.1
=EH001-X11 12 8 +A009-X4 8 4 &VA1-FLS-00EAD03-E-M2-DWD-0608/32.2
+F03-KH003 A2 9 +A009-X4 9 5 &VA1-FLS-00EAD03-E-M2-DWD-0608/32.2
+F03-KH004 A2
+F03-KH004 A1 10 +A009-X4 11 6 &VA1-FLS-00EAD03-E-M2-DWD-0608/32.4
D D
+F03-KH005 A1 11 +A009-X4 12 7 &VA1-FLS-00EAD03-E-M2-DWD-0608/32.5
=EH001-X11 14 12 +A009-X4 13 8 &VA1-FLS-00EAD03-E-M2-DWD-0608/32.5
+F03-KH006 A1 13 +A009-X4 16 9 &VA1-FLS-00EAD03-E-M2-DWD-0608/32.7
+F03-KH007 A1 14 +A009-X4 17 10 &VA1-FLS-00EAD03-E-M2-DWD-0608/32.8
=EH001-X11 16 15 +A009-X4 18 11 &VA1-FLS-00EAD03-E-M2-DWD-0608/32.8
+F03-KH008 A1 16 +A009-X4 21 12 &VA1-FLS-00EAD03-E-M2-DWD-0608/33.1
=EH001-X11 18 17 +A009-X4 22 13 &VA1-FLS-00EAD03-E-M2-DWD-0608/33.1
1 +A009-X4 24 18 =EH001-K014 14 &VA1-FLS-00EAD03-E-M2-DWD-0608/34.1
E E
2 +A009-X4 25 19 =GR002+F02-7-X4 4 &VA1-FLS-00EAD03-E-M2-DWD-0608/34.1
3 +A009-X4 26 20 =EH001-K015 14 &VA1-FLS-00EAD03-E-M2-DWD-0608/34.2
4 +A009-X4 28 21 =EH001-K016 14 &VA1-FLS-00EAD03-E-M2-DWD-0608/34.4
5 +A009-X4 30 22 =EH001-K017 14 &VA1-FLS-00EAD03-E-M2-DWD-0608/34.5
6 +A009-X4 32 23 =EH001-K020 14 &VA1-FLS-00EAD03-E-M2-DWD-0608/34.7
7 +A009-X4 34 24 =EH001-K021 14 &VA1-FLS-00EAD03-E-M2-DWD-0608/34.8
1 +A009-X4 36 25 =EH001-K022 14 &VA1-FLS-00EAD03-E-M2-DWD-0608/35.1
2 +A009-X4 37 26 &VA1-FLS-00EAD03-E-M2-DWD-0608/35.2
F F
3 +A009-X4 38 27 =EH001-K023 14 &VA1-FLS-00EAD03-E-M2-DWD-0608/35.3
4 +A009-X4 40 28 =EH001-K024 14 &VA1-FLS-00EAD03-E-M2-DWD-0608/35.4
5 +A009-X4 42 29 =EH001-K025 14 &VA1-FLS-00EAD03-E-M2-DWD-0608/35.6
6 +A009-X4 44 30 =EH001-K026 14 &VA1-FLS-00EAD03-E-M2-DWD-0608/35.7
7 +A009-X4 46 31 =EH001-K027 14 &VA1-FLS-00EAD03-E-M2-DWD-0608/35.9
1 +X-G002 UB 32 =GR001-X4 9 &VA1-FLS-00EAD03-E-M2-DWD-0608/36.2
2 +X-G002 GND 33 =GR001-X4 10 &VA1-FLS-00EAD03-E-M2-DWD-0608/36.3
GNYE +A009-X4 PE PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608/31.3
G G
229 231
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AE002+F04-X4 + F04
Appr. VUNG ANG Page 230
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4038
-4030
-4029
Strip
Cable name
Cable name
==00EAD03=AE002+F04-X4
H05VV5-F
H05VV5-F
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
GNYE +A009-X4 PE PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608/34.1
GNYE +A009-X4 PE PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608/35.2
GNYE +X-G002 PE PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608/36.3
C C
D D
E E
F F
G G
230 232
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AE002+F04-X4 + F04
Appr. VUNG ANG Page 231
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=AP010+F04-X4
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
1 =EH001-K033 14 &VA1-FLS-00EAD03-E-M2-DWD-0608/39.5
2 =GR002+F02-7-X4 6 &VA1-FLS-00EAD03-E-M2-DWD-0608/39.5
=AP020-X4 2
C C
PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608/39.6
D D
E E
F F
G G
231 233
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AP010+F04-X4 + F04
Appr. VUNG ANG Page 232
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=AP020+F04-X4
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
1 =EH001-K034 14 &VA1-FLS-00EAD03-E-M2-DWD-0608/42.5
2 =AP010-X4 2 &VA1-FLS-00EAD03-E-M2-DWD-0608/42.5
PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608/42.6
C C
D D
E E
F F
G G
232 234
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AP020+F04-X4 + F04
Appr. VUNG ANG Page 233
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=GR001+F04-X1
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
-G001 L1 1 +F02-7-X1 1 &VA1-FLS-00EAD03-E-M2-DWD-0608/49.1
-G001 L2 2 +F02-7-X1 2 &VA1-FLS-00EAD03-E-M2-DWD-0608/49.2
-G001 L3 3 +F02-7-X1 3 &VA1-FLS-00EAD03-E-M2-DWD-0608/49.2
C C
D D
E E
F F
G G
233 235
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=GR001+F04-X1 + F04
Appr. VUNG ANG Page 234
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=GR001+F04-X4
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
=CH102+F03-A001 A1 1 -F001 2 &VA1-FLS-00EAD03-E-M2-DWD-0608/49.3
=CH102+F03-A001 A2 2 -X6 2 &VA1-FLS-00EAD03-E-M2-DWD-0608/49.4
=AE001+F03-A001 A1 3 -F002 2 &VA1-FLS-00EAD03-E-M2-DWD-0608/49.4
C C
=AE001+F03-T002 X23.1 4 &VA1-FLS-00EAD03-E-M2-DWD-0608/49.4
=AE001+F03-A001 A2 5 &VA1-FLS-00EAD03-E-M2-DWD-0608/49.5
=AE001+F03-T002 X23.2 6 &VA1-FLS-00EAD03-E-M2-DWD-0608/49.5
=AE001-X4 1 7 -F003 2 &VA1-FLS-00EAD03-E-M2-DWD-0608/49.5
=AE001-X4 2 8 &VA1-FLS-00EAD03-E-M2-DWD-0608/49.6
=AE002-X4 32 9 -F004 2 &VA1-FLS-00EAD03-E-M2-DWD-0608/49.6
=AE002-X4 33 10 &VA1-FLS-00EAD03-E-M2-DWD-0608/49.7
=EH001-X10 1+ 11 -F005 2 &VA1-FLS-00EAD03-E-M2-DWD-0608/49.7
D D
=EH001-X10 1- 12 &VA1-FLS-00EAD03-E-M2-DWD-0608/49.8
=EH001-X10 31+ 13 -F006 2 &VA1-FLS-00EAD03-E-M2-DWD-0608/50.0
=EH001-X10 31- 14 &VA1-FLS-00EAD03-E-M2-DWD-0608/50.1
=EH001-X10 41+ 15 -F007 2 &VA1-FLS-00EAD03-E-M2-DWD-0608/50.1
=EH001-X10 41- 16 &VA1-FLS-00EAD03-E-M2-DWD-0608/50.2
=EH001-X10 81+ 17 -F008 2 &VA1-FLS-00EAD03-E-M2-DWD-0608/50.2
=EH001-X10 81- 18 &VA1-FLS-00EAD03-E-M2-DWD-0608/50.3
=EH001-X10 141+ 19 -F009 2 &VA1-FLS-00EAD03-E-M2-DWD-0608/50.4
E E
=EH001-X10 141- 20 &VA1-FLS-00EAD03-E-M2-DWD-0608/50.4
=EH001-X10 161+ 21 -F010 2 &VA1-FLS-00EAD03-E-M2-DWD-0608/50.5
=EH001-X10 161- 22 &VA1-FLS-00EAD03-E-M2-DWD-0608/50.5
=EH001-X10 181+ 23 -F011 2 &VA1-FLS-00EAD03-E-M2-DWD-0608/50.6
=EH001-X10 181- 24 &VA1-FLS-00EAD03-E-M2-DWD-0608/50.6
=EH001-X10 191+ 25 -F012 2 &VA1-FLS-00EAD03-E-M2-DWD-0608/50.7
=EH001-X10 191- 26 &VA1-FLS-00EAD03-E-M2-DWD-0608/50.7
=EH001-X11 1 27 -F013 2 &VA1-FLS-00EAD03-E-M2-DWD-0608/50.8
F F
=EH001-X11 20 28 &VA1-FLS-00EAD03-E-M2-DWD-0608/50.8
=EH001-X20 17 29 -F014 2 &VA1-FLS-00EAD03-E-M2-DWD-0608/51.0
=EH001-X20 9 30 &VA1-FLS-00EAD03-E-M2-DWD-0608/51.1
=EH001-X21 1 31 -F015 2 &VA1-FLS-00EAD03-E-M2-DWD-0608/51.1
=EH001-X21 10 32 &VA1-FLS-00EAD03-E-M2-DWD-0608/51.2
==00EAC51=CL101-X7 1 33 -F016 2 &VA1-FLS-00EAD03-E-M2-DWD-0608/51.2
=AE002-X4 5 34 &VA1-FLS-00EAD03-E-M2-DWD-0608/50.8
==00EAC51=CL101-X7 2 35 &VA1-FLS-00EAD03-E-M2-DWD-0608/51.3
G G
234 236
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=GR001+F04-X4 + F04
Appr. VUNG ANG Page 235
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=GR001+F04-X4
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
=AE002+F03-KH002 A2 36 &VA1-FLS-00EAD03-E-M2-DWD-0608/50.9
=GS001+F01-A001 AUX1 37 -F017 2 &VA1-FLS-00EAD03-E-M2-DWD-0608/51.4
=GS001+F01-A001 AUX2 38 &VA1-FLS-00EAD03-E-M2-DWD-0608/51.4
C C
39 -F018 2 &VA1-FLS-00EAD03-E-M2-DWD-0608/51.5
40 &VA1-FLS-00EAD03-E-M2-DWD-0608/51.5
41 -F019 2 &VA1-FLS-00EAD03-E-M2-DWD-0608/51.6
42 &VA1-FLS-00EAD03-E-M2-DWD-0608/51.6
43 -F020 2 &VA1-FLS-00EAD03-E-M2-DWD-0608/51.7
44 &VA1-FLS-00EAD03-E-M2-DWD-0608/51.7
45 -F021 2 &VA1-FLS-00EAD03-E-M2-DWD-0608/51.8
46 &VA1-FLS-00EAD03-E-M2-DWD-0608/51.8
D D
E E
F F
G G
235 237
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=GR001+F04-X4 + F04
Appr. VUNG ANG Page 236
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=AH001+F04-X4
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
=EH001-K032 14 1 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/57.8
2 =EH001-K032 11 &VA1-FLS-00EAD03-E-M2-DWD-0608+F02/57.7
C C
D D
E E
F F
G G
236 238
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AH001+F04-X4 + F04
Appr. VUNG ANG Page 237
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-1050
Strip
Cable name
Cable name
==00EAD03=AH002+F04-X2
H07 RN-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
-S004 1 1 +F02-7-X2 7 BN &VA1-FLS-00EAD03-E-M2-DWD-0608+/58.7
-S004 5 2 +F02-7-X2 8 BU &VA1-FLS-00EAD03-E-M2-DWD-0608+/58.7
-E004 PE PE +F02-7-X2 PE GNYE &VA1-FLS-00EAD03-E-M2-DWD-0608+/58.7
C C
D D
E E
F F
G G
237 239
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AH002+F04-X2 + F04
Appr. VUNG ANG Page 238
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=EH001+F04-X4
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
3 -K037 12 &VA1-FLS-00EAD03-E-M2-DWD-0608/104.8
-K037 11 4 &VA1-FLS-00EAD03-E-M2-DWD-0608/104.8
5 -K037 14 &VA1-FLS-00EAD03-E-M2-DWD-0608/104.8
C C
D D
E E
F F
G G
238 240
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+F04-X4 + F04
Appr. VUNG ANG Page 239
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4044
-4043
-4042
Strip
Cable name
Cable name
==00EAD03=EH001+F04-X10
H05VV5-F
H05VV5-F
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
2 =GS001+F01-6-X10 2 1 -A04 -X1:2 &VA1-FLS-00EAD03-E-M2-DWD-0608/75.1
1 =GS001+F01-6-X10 1 1+ =GR001-X4 11 &VA1-FLS-00EAD03-E-M2-DWD-0608/75.2
1- =GR001-X4 12 &VA1-FLS-00EAD03-E-M2-DWD-0608/75.2
C C
1 ==00EAC03=AF001+F01-5-X10 2 2 -A04 -X1:3 &VA1-FLS-00EAD03-E-M2-DWD-0608/75.2
2 ==00EAC03=AF001+F01-5-X10 1 2+ &VA1-FLS-00EAD03-E-M2-DWD-0608/75.2
2- &VA1-FLS-00EAD03-E-M2-DWD-0608/75.2
3 ==00EAC03=AF001+F01-5-X10 3 3 -A04 -X1:4 &VA1-FLS-00EAD03-E-M2-DWD-0608/75.3
3+ &VA1-FLS-00EAD03-E-M2-DWD-0608/75.3
3- &VA1-FLS-00EAD03-E-M2-DWD-0608/75.4
4 ==00EAC03=AF001+F01-5-X10 4 4 -A04 -X1:5 &VA1-FLS-00EAD03-E-M2-DWD-0608/75.4
4+ &VA1-FLS-00EAD03-E-M2-DWD-0608/75.4
D D
4- &VA1-FLS-00EAD03-E-M2-DWD-0608/75.4
5 ==00EAC03=AF001+F01-5-X10 5 5 -A04 -X1:6 &VA1-FLS-00EAD03-E-M2-DWD-0608/75.5
5+ &VA1-FLS-00EAD03-E-M2-DWD-0608/75.5
5- &VA1-FLS-00EAD03-E-M2-DWD-0608/75.5
6 ==00EAC03=AF001+F01-5-X10 6 6 -A04 -X1:7 &VA1-FLS-00EAD03-E-M2-DWD-0608/75.6
6+ &VA1-FLS-00EAD03-E-M2-DWD-0608/75.6
6- &VA1-FLS-00EAD03-E-M2-DWD-0608/75.6
7 ==00EAC03=AF001+F01-5-X10 7 7 -A04 -X1:8 &VA1-FLS-00EAD03-E-M2-DWD-0608/75.7
E E
7+ &VA1-FLS-00EAD03-E-M2-DWD-0608/75.7
7- &VA1-FLS-00EAD03-E-M2-DWD-0608/75.7
8 ==00EAC03=AF001+F01-5-X10 8 8 -A04 -X1:9 &VA1-FLS-00EAD03-E-M2-DWD-0608/75.7
8+ &VA1-FLS-00EAD03-E-M2-DWD-0608/75.7
8- &VA1-FLS-00EAD03-E-M2-DWD-0608/75.8
9 &VA1-FLS-00EAD03-E-M2-DWD-0608/75.8
9+ &VA1-FLS-00EAD03-E-M2-DWD-0608/75.8
9- &VA1-FLS-00EAD03-E-M2-DWD-0608/75.8
F F
10 &VA1-FLS-00EAD03-E-M2-DWD-0608/75.9
10+ &VA1-FLS-00EAD03-E-M2-DWD-0608/75.9
10- &VA1-FLS-00EAD03-E-M2-DWD-0608/75.9
1 ==00EAC03=AF001+F02-X1 3 11 -A04 -X1:12 &VA1-FLS-00EAD03-E-M2-DWD-0608/76.1
2 ==00EAC03=AF001+F02-X1 4 11+ &VA1-FLS-00EAD03-E-M2-DWD-0608/76.1
11- &VA1-FLS-00EAD03-E-M2-DWD-0608/76.2
3 ==00EAC03=AF001+F02-X10 2 12 -A04 -X1:13 &VA1-FLS-00EAD03-E-M2-DWD-0608/76.2
==00EAC03=AF001+F02-X10 1 12+ &VA1-FLS-00EAD03-E-M2-DWD-0608/76.2
G G
239 241
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+F04-X10 + F04
Appr. VUNG ANG Page 240
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4049
-4067
-4066
-4046
-4045
-4044
Strip
Cable name
Cable name
==00EAD03=EH001+F04-X10
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
12- &VA1-FLS-00EAD03-E-M2-DWD-0608/76.2
4 ==00EAC03=AF001+F02-X10 4 13 -A04 -X1:14 &VA1-FLS-00EAD03-E-M2-DWD-0608/76.3
==00EAC03=AF001+F02-X10 3 13+ &VA1-FLS-00EAD03-E-M2-DWD-0608/76.3
C C
13- &VA1-FLS-00EAD03-E-M2-DWD-0608/76.3
5 ==00EAC03=AF001+F02-X1 13 14 -A04 -X1:15 &VA1-FLS-00EAD03-E-M2-DWD-0608/76.4
==00EAC03=AF001+F02-X1 14 14+ &VA1-FLS-00EAD03-E-M2-DWD-0608/76.4
14- &VA1-FLS-00EAD03-E-M2-DWD-0608/76.4
1 =CH101+X-S001 14 15 -A04 -X1:16 &VA1-FLS-00EAD03-E-M2-DWD-0608/76.5
2 =CH101+X-S001 13 15+ &VA1-FLS-00EAD03-E-M2-DWD-0608/76.5
15- &VA1-FLS-00EAD03-E-M2-DWD-0608/76.5
3 =CH101+X-S001 24 16 -A04 -X1:17 &VA1-FLS-00EAD03-E-M2-DWD-0608/76.6
D D
16+ &VA1-FLS-00EAD03-E-M2-DWD-0608/76.6
16- &VA1-FLS-00EAD03-E-M2-DWD-0608/76.6
4 =CH101+X-S002 14 17 -A04 -X1:18 &VA1-FLS-00EAD03-E-M2-DWD-0608/76.7
17+ &VA1-FLS-00EAD03-E-M2-DWD-0608/76.7
17- &VA1-FLS-00EAD03-E-M2-DWD-0608/76.7
5 =CH101+X-S003 12 18 -A04 -X1:19 &VA1-FLS-00EAD03-E-M2-DWD-0608/76.7
18+ &VA1-FLS-00EAD03-E-M2-DWD-0608/76.7
18- &VA1-FLS-00EAD03-E-M2-DWD-0608/76.8
E E
19 &VA1-FLS-00EAD03-E-M2-DWD-0608/76.8
19+ &VA1-FLS-00EAD03-E-M2-DWD-0608/76.8
-A04 -X1:20 19- &VA1-FLS-00EAD03-E-M2-DWD-0608/76.8
20 &VA1-FLS-00EAD03-E-M2-DWD-0608/76.9
20+ &VA1-FLS-00EAD03-E-M2-DWD-0608/76.9
20- &VA1-FLS-00EAD03-E-M2-DWD-0608/76.9
2 =GU001+F01-4-X10 2 21 -A04 -X1:22 &VA1-FLS-00EAD03-E-M2-DWD-0608/77.1
1 =GU001+F01-4-X10 1 21+ &VA1-FLS-00EAD03-E-M2-DWD-0608/77.2
F F
21- &VA1-FLS-00EAD03-E-M2-DWD-0608/77.2
1 ==00EAC03=CH111+X-S001 14 22 -A04 -X1:23 &VA1-FLS-00EAD03-E-M2-DWD-0608/77.2
2 ==00EAC03=CH111+X-S001 13 22+ &VA1-FLS-00EAD03-E-M2-DWD-0608/77.2
22- &VA1-FLS-00EAD03-E-M2-DWD-0608/77.2
1 ==00EAC03=CH112+X-S002 14 23 -A04 -X1:24 &VA1-FLS-00EAD03-E-M2-DWD-0608/77.3
2 ==00EAC03=CH112+X-S002 13 23+ &VA1-FLS-00EAD03-E-M2-DWD-0608/77.3
23- &VA1-FLS-00EAD03-E-M2-DWD-0608/77.3
1 ==00EAC03=CG101+X-S001 1 24 -A04 -X1:25 &VA1-FLS-00EAD03-E-M2-DWD-0608/77.4
G G
240 242
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+F04-X10 + F04
Appr. VUNG ANG Page 241
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4068
==00EAC51-4069
==00EAC51-4068
-4058
-4057
-4056
-4049
Strip
Cable name
Cable name
==00EAD03=EH001+F04-X10
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
2 ==00EAC03=CG101+X-S001 11 24+ &VA1-FLS-00EAD03-E-M2-DWD-0608/77.4
24- &VA1-FLS-00EAD03-E-M2-DWD-0608/77.4
3 ==00EAC03=CG101+X-S001 2 25 -A04 -X1:26 &VA1-FLS-00EAD03-E-M2-DWD-0608/77.5
C C
4 ==00EAC03=CG101+X-S001 31 25+ &VA1-FLS-00EAD03-E-M2-DWD-0608/77.5
25- &VA1-FLS-00EAD03-E-M2-DWD-0608/77.5
1 ==00EAC03=CS101+X-X10 3 26 -A04 -X1:27 &VA1-FLS-00EAD03-E-M2-DWD-0608/77.6
2 ==00EAC03=CS101+X-X10 1 26+ &VA1-FLS-00EAD03-E-M2-DWD-0608/77.6
3 ==00EAC03=CS101+X-X10 2 26- &VA1-FLS-00EAD03-E-M2-DWD-0608/77.6
1 ==00EAC03=CT101-S001 22 27 -A04 -X1:28 &VA1-FLS-00EAD03-E-M2-DWD-0608/77.7
2 ==00EAC03=CT101-S001 21 27+ &VA1-FLS-00EAD03-E-M2-DWD-0608/77.7
27- &VA1-FLS-00EAD03-E-M2-DWD-0608/77.7
D D
1 ==00EAC03=CG104+X-X10 2 28 -A04 -X1:29 &VA1-FLS-00EAD03-E-M2-DWD-0608/77.7
2 ==00EAC03=CG104+X-X10 1 28+ &VA1-FLS-00EAD03-E-M2-DWD-0608/77.7
28- &VA1-FLS-00EAD03-E-M2-DWD-0608/77.8
29 &VA1-FLS-00EAD03-E-M2-DWD-0608/77.8
29+ &VA1-FLS-00EAD03-E-M2-DWD-0608/77.8
29- &VA1-FLS-00EAD03-E-M2-DWD-0608/77.8
30 &VA1-FLS-00EAD03-E-M2-DWD-0608/77.9
30+ &VA1-FLS-00EAD03-E-M2-DWD-0608/77.9
E E
30- &VA1-FLS-00EAD03-E-M2-DWD-0608/77.9
1 ==00EAC51=CH121+X-S001 14 31 -A04 -X1:32 &VA1-FLS-00EAD03-E-M2-DWD-0608/78.1
2 ==00EAC51=CH121+X-S001 13 31+ =GR001-X4 13 &VA1-FLS-00EAD03-E-M2-DWD-0608/78.1
31- =GR001-X4 14 &VA1-FLS-00EAD03-E-M2-DWD-0608/78.1
1 ==00EAC51=CH122+X-S002 14 32 -A04 -X1:33 &VA1-FLS-00EAD03-E-M2-DWD-0608/78.2
2 ==00EAC51=CH122+X-S002 13 32+ &VA1-FLS-00EAD03-E-M2-DWD-0608/78.2
32- &VA1-FLS-00EAD03-E-M2-DWD-0608/78.2
1 ==00EAC03=CG105+X-S001 1 33 -A04 -X1:34 &VA1-FLS-00EAD03-E-M2-DWD-0608/78.3
F F
2 ==00EAC03=CG105+X-S001 11 33+ &VA1-FLS-00EAD03-E-M2-DWD-0608/78.3
33- &VA1-FLS-00EAD03-E-M2-DWD-0608/78.3
3 ==00EAC03=CG105+X-S001 2 34 -A04 -X1:35 &VA1-FLS-00EAD03-E-M2-DWD-0608/78.4
4 ==00EAC03=CG105+X-S001 31 34+ &VA1-FLS-00EAD03-E-M2-DWD-0608/78.4
34- &VA1-FLS-00EAD03-E-M2-DWD-0608/78.4
==00EAC51=CL101-X7 4 35 -A04 -X1:36 &VA1-FLS-00EAD03-E-M2-DWD-0608/78.5
==00EAC51=CL101-X7 3 35+ &VA1-FLS-00EAD03-E-M2-DWD-0608/78.5
35- &VA1-FLS-00EAD03-E-M2-DWD-0608/78.5
G G
241 243
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+F04-X10 + F04
Appr. VUNG ANG Page 242
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4071
-4070
Strip
Cable name
Cable name
==00EAD03=EH001+F04-X10
H05VV5-F
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
=GU001+F01-4-X10 4 36 -A04 -X1:37 &VA1-FLS-00EAD03-E-M2-DWD-0608/78.6
=GU001+F01-4-X10 3 36+ &VA1-FLS-00EAD03-E-M2-DWD-0608/78.6
36- &VA1-FLS-00EAD03-E-M2-DWD-0608/78.6
C C
==00EAC51=CL101-X4 6 37 -A04 -X1:38 &VA1-FLS-00EAD03-E-M2-DWD-0608/78.7
==00EAC51=CL101-X4 5 37+ &VA1-FLS-00EAD03-E-M2-DWD-0608/78.7
37- &VA1-FLS-00EAD03-E-M2-DWD-0608/78.7
==00EAC03=AF001+F01-5-F002 14 38 -A04 -X1:39 &VA1-FLS-00EAD03-E-M2-DWD-0608/78.7
==00EAC03=AF001+F01-5-F002 13 38+ &VA1-FLS-00EAD03-E-M2-DWD-0608/78.7
38- &VA1-FLS-00EAD03-E-M2-DWD-0608/78.8
39 &VA1-FLS-00EAD03-E-M2-DWD-0608/78.8
39+ &VA1-FLS-00EAD03-E-M2-DWD-0608/78.8
D D
-A04 -X1:40 39- &VA1-FLS-00EAD03-E-M2-DWD-0608/78.8
40 &VA1-FLS-00EAD03-E-M2-DWD-0608/78.9
40+ &VA1-FLS-00EAD03-E-M2-DWD-0608/78.9
40- &VA1-FLS-00EAD03-E-M2-DWD-0608/78.9
1 =CH111+X-S001 14 41 -A05 -X1:2 &VA1-FLS-00EAD03-E-M2-DWD-0608/79.1
2 =CH111+X-S001 13 41+ =GR001-X4 15 &VA1-FLS-00EAD03-E-M2-DWD-0608/79.1
41- =GR001-X4 16 &VA1-FLS-00EAD03-E-M2-DWD-0608/79.2
3 =CH111+X-S001 24 42 -A05 -X1:3 &VA1-FLS-00EAD03-E-M2-DWD-0608/79.2
E E
42+ &VA1-FLS-00EAD03-E-M2-DWD-0608/79.2
42- &VA1-FLS-00EAD03-E-M2-DWD-0608/79.2
4 =CH111+X-S002 14 43 -A05 -X1:4 &VA1-FLS-00EAD03-E-M2-DWD-0608/79.3
43+ &VA1-FLS-00EAD03-E-M2-DWD-0608/79.3
43- &VA1-FLS-00EAD03-E-M2-DWD-0608/79.3
5 =CH111+X-S003 14 44 -A05 -X1:5 &VA1-FLS-00EAD03-E-M2-DWD-0608/79.4
44+ &VA1-FLS-00EAD03-E-M2-DWD-0608/79.4
44- &VA1-FLS-00EAD03-E-M2-DWD-0608/79.4
F F
2 =AE001+A010-X10 1 45 -A05 -X1:6 &VA1-FLS-00EAD03-E-M2-DWD-0608/79.5
1 =AE001+A010-X10 2 45+ &VA1-FLS-00EAD03-E-M2-DWD-0608/79.5
45- &VA1-FLS-00EAD03-E-M2-DWD-0608/79.5
3 =AE001+A010-X10 3 46 -A05 -X1:7 &VA1-FLS-00EAD03-E-M2-DWD-0608/79.6
46+ &VA1-FLS-00EAD03-E-M2-DWD-0608/79.6
46- &VA1-FLS-00EAD03-E-M2-DWD-0608/79.6
4 =AE001+A010-X10 5 47 -A05 -X1:8 &VA1-FLS-00EAD03-E-M2-DWD-0608/79.7
47+ &VA1-FLS-00EAD03-E-M2-DWD-0608/79.7
G G
242 244
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+F04-X10 + F04
Appr. VUNG ANG Page 243
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4018
-4017
-4016
-4015
-4077
-4076
-4071
Strip
Cable name
Cable name
==00EAD03=EH001+F04-X10
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
47- &VA1-FLS-00EAD03-E-M2-DWD-0608/79.7
5 =AE001+A010-X10 7 48 -A05 -X1:9 &VA1-FLS-00EAD03-E-M2-DWD-0608/79.7
48+ &VA1-FLS-00EAD03-E-M2-DWD-0608/79.8
C C
48- &VA1-FLS-00EAD03-E-M2-DWD-0608/79.8
49 &VA1-FLS-00EAD03-E-M2-DWD-0608/79.8
49+ &VA1-FLS-00EAD03-E-M2-DWD-0608/79.8
49- &VA1-FLS-00EAD03-E-M2-DWD-0608/79.8
50 &VA1-FLS-00EAD03-E-M2-DWD-0608/79.9
50+ &VA1-FLS-00EAD03-E-M2-DWD-0608/79.9
50- &VA1-FLS-00EAD03-E-M2-DWD-0608/79.9
1 +X-S005 4 51 -A05 -X1:12 &VA1-FLS-00EAD03-E-M2-DWD-0608/80.1
D D
2 +X-S005 1 51+ &VA1-FLS-00EAD03-E-M2-DWD-0608/80.1
+X-S005 2 51- &VA1-FLS-00EAD03-E-M2-DWD-0608/80.2
1 +X-S006 4 52 -A05 -X1:13 &VA1-FLS-00EAD03-E-M2-DWD-0608/80.2
2 +X-S006 1 52+ &VA1-FLS-00EAD03-E-M2-DWD-0608/80.2
+X-S006 2 52- &VA1-FLS-00EAD03-E-M2-DWD-0608/80.2
+LC01-X4 6 53 -A05 -X1:14 &VA1-FLS-00EAD03-E-M2-DWD-0608/80.3
+LC01-X4 5 53+ &VA1-FLS-00EAD03-E-M2-DWD-0608/80.3
53- &VA1-FLS-00EAD03-E-M2-DWD-0608/80.3
E E
3 =CG119+X-S002 14 54 -A05 -X1:15 &VA1-FLS-00EAD03-E-M2-DWD-0608/80.4
4 =CG119+X-S002 13 54+ &VA1-FLS-00EAD03-E-M2-DWD-0608/80.4
54- &VA1-FLS-00EAD03-E-M2-DWD-0608/80.4
3 =CG120+X-S003 14 55 -A05 -X1:16 &VA1-FLS-00EAD03-E-M2-DWD-0608/80.5
4 =CG120+X-S003 13 55+ &VA1-FLS-00EAD03-E-M2-DWD-0608/80.5
55- &VA1-FLS-00EAD03-E-M2-DWD-0608/80.5
3 =CG117+X-S004 14 56 -A05 -X1:17 &VA1-FLS-00EAD03-E-M2-DWD-0608/80.6
4 =CG117+X-S004 13 56+ &VA1-FLS-00EAD03-E-M2-DWD-0608/80.6
F F
56- &VA1-FLS-00EAD03-E-M2-DWD-0608/80.6
3 =CG118+X-S005 14 57 -A05 -X1:18 &VA1-FLS-00EAD03-E-M2-DWD-0608/80.7
4 =CG118+X-S005 13 57+ &VA1-FLS-00EAD03-E-M2-DWD-0608/80.7
57- &VA1-FLS-00EAD03-E-M2-DWD-0608/80.7
=AE001+F03-A001 14 58 -A05 -X1:19 &VA1-FLS-00EAD03-E-M2-DWD-0608/80.7
=AE001+F03-A001 13 58+ &VA1-FLS-00EAD03-E-M2-DWD-0608/80.7
58- &VA1-FLS-00EAD03-E-M2-DWD-0608/80.8
59 &VA1-FLS-00EAD03-E-M2-DWD-0608/80.8
G G
243 245
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+F04-X10 + F04
Appr. VUNG ANG Page 244
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=EH001+F04-X10
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
59+ &VA1-FLS-00EAD03-E-M2-DWD-0608/80.8
-A05 -X1:20 59- &VA1-FLS-00EAD03-E-M2-DWD-0608/80.8
60 &VA1-FLS-00EAD03-E-M2-DWD-0608/80.9
C C
60+ &VA1-FLS-00EAD03-E-M2-DWD-0608/80.9
60- &VA1-FLS-00EAD03-E-M2-DWD-0608/80.9
=CT111+F03-K001 11 61 -A05 -X1:22 &VA1-FLS-00EAD03-E-M2-DWD-0608/81.1
=CT111+F03-K001 14 61+ &VA1-FLS-00EAD03-E-M2-DWD-0608/81.1
61- &VA1-FLS-00EAD03-E-M2-DWD-0608/81.2
=CT112+F03-K002 11 62 -A05 -X1:23 &VA1-FLS-00EAD03-E-M2-DWD-0608/81.2
=CT112+F03-K002 14 62+ &VA1-FLS-00EAD03-E-M2-DWD-0608/81.2
62- &VA1-FLS-00EAD03-E-M2-DWD-0608/81.2
D D
=CT113+F03-K003 11 63 -A05 -X1:24 &VA1-FLS-00EAD03-E-M2-DWD-0608/81.3
=CT113+F03-K003 14 63+ &VA1-FLS-00EAD03-E-M2-DWD-0608/81.3
63- &VA1-FLS-00EAD03-E-M2-DWD-0608/81.3
=CT114+F03-K004 11 64 -A05 -X1:25 &VA1-FLS-00EAD03-E-M2-DWD-0608/81.4
=CT114+F03-K004 14 64+ &VA1-FLS-00EAD03-E-M2-DWD-0608/81.4
64- &VA1-FLS-00EAD03-E-M2-DWD-0608/81.4
=AE001+F01-2-X10 5 65 -A05 -X1:26 &VA1-FLS-00EAD03-E-M2-DWD-0608/81.5
=AE001+F01-2-X10 1 65+ &VA1-FLS-00EAD03-E-M2-DWD-0608/81.5
E E
65- &VA1-FLS-00EAD03-E-M2-DWD-0608/81.5
=AE001+F01-2-X10 6 66 -A05 -X1:27 &VA1-FLS-00EAD03-E-M2-DWD-0608/81.6
=AE001+F01-2-X10 2 66+ &VA1-FLS-00EAD03-E-M2-DWD-0608/81.6
66- &VA1-FLS-00EAD03-E-M2-DWD-0608/81.6
=AE001+F01-2-X10 7 67 -A05 -X1:28 &VA1-FLS-00EAD03-E-M2-DWD-0608/81.7
=AE001+F01-2-X10 3 67+ &VA1-FLS-00EAD03-E-M2-DWD-0608/81.7
67- &VA1-FLS-00EAD03-E-M2-DWD-0608/81.7
=AE001+F01-2-X10 8 68 -A05 -X1:29 &VA1-FLS-00EAD03-E-M2-DWD-0608/81.7
F F
=AE001+F01-2-X10 4 68+ &VA1-FLS-00EAD03-E-M2-DWD-0608/81.7
68- &VA1-FLS-00EAD03-E-M2-DWD-0608/81.8
69 &VA1-FLS-00EAD03-E-M2-DWD-0608/81.8
69+ &VA1-FLS-00EAD03-E-M2-DWD-0608/81.8
69- &VA1-FLS-00EAD03-E-M2-DWD-0608/81.8
70 &VA1-FLS-00EAD03-E-M2-DWD-0608/81.9
70+ &VA1-FLS-00EAD03-E-M2-DWD-0608/81.9
70- &VA1-FLS-00EAD03-E-M2-DWD-0608/81.9
G G
244 246
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+F04-X10 + F04
Appr. VUNG ANG Page 245
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4078
Strip
Cable name
Cable name
==00EAD03=EH001+F04-X10
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
=AE001+F03-Q004 14 71 -A05 -X1:32 &VA1-FLS-00EAD03-E-M2-DWD-0608/82.1
=AE001+F03-Q004 13 71+ &VA1-FLS-00EAD03-E-M2-DWD-0608/82.1
71- &VA1-FLS-00EAD03-E-M2-DWD-0608/82.2
C C
+A010-X10 5 72 -A05 -X1:33 &VA1-FLS-00EAD03-E-M2-DWD-0608/82.2
+A010-X10 1 72+ &VA1-FLS-00EAD03-E-M2-DWD-0608/82.2
72- &VA1-FLS-00EAD03-E-M2-DWD-0608/82.2
+A010-X10 6 73 -A05 -X1:34 &VA1-FLS-00EAD03-E-M2-DWD-0608/82.3
73+ &VA1-FLS-00EAD03-E-M2-DWD-0608/82.3
73- &VA1-FLS-00EAD03-E-M2-DWD-0608/82.3
+A010-X10 7 74 -A05 -X1:35 &VA1-FLS-00EAD03-E-M2-DWD-0608/82.4
74+ &VA1-FLS-00EAD03-E-M2-DWD-0608/82.4
D D
74- &VA1-FLS-00EAD03-E-M2-DWD-0608/82.4
+A010-X10 8 75 -A05 -X1:36 &VA1-FLS-00EAD03-E-M2-DWD-0608/82.5
75+ &VA1-FLS-00EAD03-E-M2-DWD-0608/82.5
75- &VA1-FLS-00EAD03-E-M2-DWD-0608/82.5
=AE001+F01-2-F006 14 76 -A05 -X1:37 &VA1-FLS-00EAD03-E-M2-DWD-0608/82.6
=AE001+F01-2-F006 13 76+ &VA1-FLS-00EAD03-E-M2-DWD-0608/82.6
76- &VA1-FLS-00EAD03-E-M2-DWD-0608/82.6
1 =AE001+X-R001 T2 77 -A05 -X1:38 &VA1-FLS-00EAD03-E-M2-DWD-0608/82.7
E E
2 =AE001+X-R001 T1 77+ &VA1-FLS-00EAD03-E-M2-DWD-0608/82.7
77- &VA1-FLS-00EAD03-E-M2-DWD-0608/82.7
-K011 21 78 -A05 -X1:39 &VA1-FLS-00EAD03-E-M2-DWD-0608/82.7
-K011 24 78+ &VA1-FLS-00EAD03-E-M2-DWD-0608/82.8
78- &VA1-FLS-00EAD03-E-M2-DWD-0608/82.8
79 &VA1-FLS-00EAD03-E-M2-DWD-0608/82.8
79+ &VA1-FLS-00EAD03-E-M2-DWD-0608/82.8
-A05 -X1:40 79- &VA1-FLS-00EAD03-E-M2-DWD-0608/82.8
F F
80 &VA1-FLS-00EAD03-E-M2-DWD-0608/82.9
80+ &VA1-FLS-00EAD03-E-M2-DWD-0608/82.9
80- &VA1-FLS-00EAD03-E-M2-DWD-0608/82.9
=AE002+F02-X1 3 81 -A06 -X1:2 &VA1-FLS-00EAD03-E-M2-DWD-0608/83.1
=AE002+F02-X1 4 81+ =GR001-X4 17 &VA1-FLS-00EAD03-E-M2-DWD-0608/83.1
81- =GR001-X4 18 &VA1-FLS-00EAD03-E-M2-DWD-0608/83.2
=AE002+F02-X10 2 82 -A06 -X1:3 &VA1-FLS-00EAD03-E-M2-DWD-0608/83.2
=AE002+F02-X10 1 82+ &VA1-FLS-00EAD03-E-M2-DWD-0608/83.2
G G
245 247
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+F04-X10 + F04
Appr. VUNG ANG Page 246
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4079
Strip
Cable name
Cable name
==00EAD03=EH001+F04-X10
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
82- &VA1-FLS-00EAD03-E-M2-DWD-0608/83.2
=AE002+F02-X10 4 83 -A06 -X1:4 &VA1-FLS-00EAD03-E-M2-DWD-0608/83.3
=AE002+F02-X10 3 83+ &VA1-FLS-00EAD03-E-M2-DWD-0608/83.3
C C
83- &VA1-FLS-00EAD03-E-M2-DWD-0608/83.3
=AE002+F02-X1 13 84 -A06 -X1:5 &VA1-FLS-00EAD03-E-M2-DWD-0608/83.4
=AE002+F02-X1 14 84+ &VA1-FLS-00EAD03-E-M2-DWD-0608/83.4
84- &VA1-FLS-00EAD03-E-M2-DWD-0608/83.4
=AE002+F02-X1 5 85 -A06 -X1:6 &VA1-FLS-00EAD03-E-M2-DWD-0608/83.5
=AE002+F02-X1 8 85+ &VA1-FLS-00EAD03-E-M2-DWD-0608/83.5
85- &VA1-FLS-00EAD03-E-M2-DWD-0608/83.5
=AE002-K001 11 86 -A06 -X1:7 &VA1-FLS-00EAD03-E-M2-DWD-0608/83.6
D D
=AE002-K001 14 86+ &VA1-FLS-00EAD03-E-M2-DWD-0608/83.6
86- &VA1-FLS-00EAD03-E-M2-DWD-0608/83.6
=GR002+F02-7-Q001 14 87 -A06 -X1:8 &VA1-FLS-00EAD03-E-M2-DWD-0608/83.7
=GR002+F02-7-Q001 13 87+ &VA1-FLS-00EAD03-E-M2-DWD-0608/83.7
87- &VA1-FLS-00EAD03-E-M2-DWD-0608/83.7
=AE002+F02-7-F002 14 88 -A06 -X1:9 &VA1-FLS-00EAD03-E-M2-DWD-0608/83.7
=AE002+F02-7-F002 13 88+ &VA1-FLS-00EAD03-E-M2-DWD-0608/83.7
88- &VA1-FLS-00EAD03-E-M2-DWD-0608/83.8
E E
89 &VA1-FLS-00EAD03-E-M2-DWD-0608/83.8
89+ &VA1-FLS-00EAD03-E-M2-DWD-0608/83.8
89- &VA1-FLS-00EAD03-E-M2-DWD-0608/83.8
90 &VA1-FLS-00EAD03-E-M2-DWD-0608/83.9
90+ &VA1-FLS-00EAD03-E-M2-DWD-0608/83.9
90- &VA1-FLS-00EAD03-E-M2-DWD-0608/83.9
1 =CH121+X-S004 14 91 -A06 -X1:12 &VA1-FLS-00EAD03-E-M2-DWD-0608/84.1
2 =CH121+X-S004 13 91+ &VA1-FLS-00EAD03-E-M2-DWD-0608/84.1
F F
91- &VA1-FLS-00EAD03-E-M2-DWD-0608/84.2
3 =CH121+X-S004 24 92 -A06 -X1:13 &VA1-FLS-00EAD03-E-M2-DWD-0608/84.2
92+ &VA1-FLS-00EAD03-E-M2-DWD-0608/84.2
92- &VA1-FLS-00EAD03-E-M2-DWD-0608/84.2
4 =CH121+X-S005 14 93 -A06 -X1:14 &VA1-FLS-00EAD03-E-M2-DWD-0608/84.3
93+ &VA1-FLS-00EAD03-E-M2-DWD-0608/84.3
93- &VA1-FLS-00EAD03-E-M2-DWD-0608/84.3
5 =CH121+X-S006 14 94 -A06 -X1:15 &VA1-FLS-00EAD03-E-M2-DWD-0608/84.4
G G
246 248
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+F04-X10 + F04
Appr. VUNG ANG Page 247
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4082
-4081
-4080
Strip
Cable name
Cable name
==00EAD03=EH001+F04-X10
H05VV5-F
H05VV5-F
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
94+ &VA1-FLS-00EAD03-E-M2-DWD-0608/84.4
94- &VA1-FLS-00EAD03-E-M2-DWD-0608/84.4
1 =CG121+X-S004 14 95 -A06 -X1:16 &VA1-FLS-00EAD03-E-M2-DWD-0608/84.5
C C
2 =CG121+X-S004 13 95+ &VA1-FLS-00EAD03-E-M2-DWD-0608/84.5
95- &VA1-FLS-00EAD03-E-M2-DWD-0608/84.5
1 =CG122+X-S005 14 96 -A06 -X1:17 &VA1-FLS-00EAD03-E-M2-DWD-0608/84.6
2 =CG122+X-S005 13 96+ &VA1-FLS-00EAD03-E-M2-DWD-0608/84.6
96- &VA1-FLS-00EAD03-E-M2-DWD-0608/84.6
1 =CG123+X-S006 14 97 -A06 -X1:18 &VA1-FLS-00EAD03-E-M2-DWD-0608/84.7
2 =CG123+X-S006 13 97+ &VA1-FLS-00EAD03-E-M2-DWD-0608/84.7
97- &VA1-FLS-00EAD03-E-M2-DWD-0608/84.7
D D
98 -A06 -X1:19 &VA1-FLS-00EAD03-E-M2-DWD-0608/84.7
98+ &VA1-FLS-00EAD03-E-M2-DWD-0608/84.7
98- &VA1-FLS-00EAD03-E-M2-DWD-0608/84.8
99 &VA1-FLS-00EAD03-E-M2-DWD-0608/84.8
99+ &VA1-FLS-00EAD03-E-M2-DWD-0608/84.8
-A06 -X1:20 99- &VA1-FLS-00EAD03-E-M2-DWD-0608/84.8
100 &VA1-FLS-00EAD03-E-M2-DWD-0608/84.9
100+ &VA1-FLS-00EAD03-E-M2-DWD-0608/84.9
E E
100- &VA1-FLS-00EAD03-E-M2-DWD-0608/84.9
=AE002+F03-KH002 11 101 -A06 -X1:22 &VA1-FLS-00EAD03-E-M2-DWD-0608/85.1
=AE002+F03-KH002 14 101+ &VA1-FLS-00EAD03-E-M2-DWD-0608/85.2
101- &VA1-FLS-00EAD03-E-M2-DWD-0608/85.2
=AE002+F03-KH003 11 102 -A06 -X1:23 &VA1-FLS-00EAD03-E-M2-DWD-0608/85.2
=AE002+F03-KH003 14 102+ &VA1-FLS-00EAD03-E-M2-DWD-0608/85.2
102- &VA1-FLS-00EAD03-E-M2-DWD-0608/85.3
=AE002+F03-KH004 11 103 -A06 -X1:24 &VA1-FLS-00EAD03-E-M2-DWD-0608/85.3
F F
=AE002+F03-KH004 14 103+ &VA1-FLS-00EAD03-E-M2-DWD-0608/85.3
103- &VA1-FLS-00EAD03-E-M2-DWD-0608/85.4
=AE002+F03-KH005 11 104 -A06 -X1:25 &VA1-FLS-00EAD03-E-M2-DWD-0608/85.4
=AE002+F03-KH005 14 104+ &VA1-FLS-00EAD03-E-M2-DWD-0608/85.4
104- &VA1-FLS-00EAD03-E-M2-DWD-0608/85.4
=AE002+F03-KH006 11 105 -A06 -X1:26 &VA1-FLS-00EAD03-E-M2-DWD-0608/85.5
=AE002+F03-KH006 14 105+ &VA1-FLS-00EAD03-E-M2-DWD-0608/85.5
105- &VA1-FLS-00EAD03-E-M2-DWD-0608/85.5
G G
247 249
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+F04-X10 + F04
Appr. VUNG ANG Page 248
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4084
-4083
Strip
Cable name
Cable name
==00EAD03=EH001+F04-X10
H05VV5-F
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
=AE002+F03-KH007 11 106 -A06 -X1:27 &VA1-FLS-00EAD03-E-M2-DWD-0608/85.6
=AE002+F03-KH007 14 106+ &VA1-FLS-00EAD03-E-M2-DWD-0608/85.6
106- &VA1-FLS-00EAD03-E-M2-DWD-0608/85.6
C C
=AE002+F03-KH008 11 107 -A06 -X1:28 &VA1-FLS-00EAD03-E-M2-DWD-0608/85.7
=AE002+F03-KH008 14 107+ &VA1-FLS-00EAD03-E-M2-DWD-0608/85.7
107- &VA1-FLS-00EAD03-E-M2-DWD-0608/85.7
2 =AE002+A009-X4 49 108 -A06 -X1:29 &VA1-FLS-00EAD03-E-M2-DWD-0608/85.7
1 =AE002+A009-X4 48 108+ &VA1-FLS-00EAD03-E-M2-DWD-0608/85.7
108- &VA1-FLS-00EAD03-E-M2-DWD-0608/85.8
109 &VA1-FLS-00EAD03-E-M2-DWD-0608/85.8
109+ &VA1-FLS-00EAD03-E-M2-DWD-0608/85.8
D D
109- &VA1-FLS-00EAD03-E-M2-DWD-0608/85.8
110 &VA1-FLS-00EAD03-E-M2-DWD-0608/85.9
110+ &VA1-FLS-00EAD03-E-M2-DWD-0608/85.9
110- &VA1-FLS-00EAD03-E-M2-DWD-0608/85.9
2 =AE002+A009-X4 51 111 -A06 -X1:32 &VA1-FLS-00EAD03-E-M2-DWD-0608/86.1
=AE002+A009-X4 50 111+ &VA1-FLS-00EAD03-E-M2-DWD-0608/86.1
111- &VA1-FLS-00EAD03-E-M2-DWD-0608/86.2
4 =AE002+A009-X4 54 112 -A06 -X1:33 &VA1-FLS-00EAD03-E-M2-DWD-0608/86.2
E E
=AE002+A009-X4 53 112+ &VA1-FLS-00EAD03-E-M2-DWD-0608/86.2
112- &VA1-FLS-00EAD03-E-M2-DWD-0608/86.2
5 =AE002+A009-X4 57 113 -A06 -X1:34 &VA1-FLS-00EAD03-E-M2-DWD-0608/86.3
=AE002+A009-X4 56 113+ &VA1-FLS-00EAD03-E-M2-DWD-0608/86.3
113- &VA1-FLS-00EAD03-E-M2-DWD-0608/86.3
=GR002+F02-7-F001 14 114 -A06 -X1:35 &VA1-FLS-00EAD03-E-M2-DWD-0608/86.4
=GR002+F02-7-F001 13 114+ &VA1-FLS-00EAD03-E-M2-DWD-0608/86.4
114- &VA1-FLS-00EAD03-E-M2-DWD-0608/86.4
F F
=GR002+F02-7-F002 14 115 -A06 -X1:36 &VA1-FLS-00EAD03-E-M2-DWD-0608/86.5
=GR002+F02-7-F002 13 115+ &VA1-FLS-00EAD03-E-M2-DWD-0608/86.5
115- &VA1-FLS-00EAD03-E-M2-DWD-0608/86.5
=GR002+F02-7-F003 14 116 -A06 -X1:37 &VA1-FLS-00EAD03-E-M2-DWD-0608/86.6
=GR002+F02-7-F003 13 116+ &VA1-FLS-00EAD03-E-M2-DWD-0608/86.6
116- &VA1-FLS-00EAD03-E-M2-DWD-0608/86.6
=GR002+F02-7-F004 14 117 -A06 -X1:38 &VA1-FLS-00EAD03-E-M2-DWD-0608/86.7
=GR002+F02-7-F004 13 117+ &VA1-FLS-00EAD03-E-M2-DWD-0608/86.7
G G
248 250
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+F04-X10 + F04
Appr. VUNG ANG Page 249
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=EH001+F04-X10
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
117- &VA1-FLS-00EAD03-E-M2-DWD-0608/86.7
=GR002+F02-7-F005 14 118 -A06 -X1:39 &VA1-FLS-00EAD03-E-M2-DWD-0608/86.7
=GR002+F02-7-F005 13 118+ &VA1-FLS-00EAD03-E-M2-DWD-0608/86.7
C C
118- &VA1-FLS-00EAD03-E-M2-DWD-0608/86.8
119 &VA1-FLS-00EAD03-E-M2-DWD-0608/86.8
119+ &VA1-FLS-00EAD03-E-M2-DWD-0608/86.8
-A06 -X1:40 119- &VA1-FLS-00EAD03-E-M2-DWD-0608/86.8
120 &VA1-FLS-00EAD03-E-M2-DWD-0608/86.9
120+ &VA1-FLS-00EAD03-E-M2-DWD-0608/86.9
120- &VA1-FLS-00EAD03-E-M2-DWD-0608/86.9
=AP010+F02-X1 3 121 -A07 -X1:2 &VA1-FLS-00EAD03-E-M2-DWD-0608/87.1
D D
=AP010+F02-X1 4 121+ &VA1-FLS-00EAD03-E-M2-DWD-0608/87.1
121- &VA1-FLS-00EAD03-E-M2-DWD-0608/87.2
=AP010+F02-X10 2 122 -A07 -X1:3 &VA1-FLS-00EAD03-E-M2-DWD-0608/87.2
=AP010+F02-X10 1 122+ &VA1-FLS-00EAD03-E-M2-DWD-0608/87.2
122- &VA1-FLS-00EAD03-E-M2-DWD-0608/87.2
=AP010+F02-X10 4 123 -A07 -X1:4 &VA1-FLS-00EAD03-E-M2-DWD-0608/87.3
=AP010+F02-X10 3 123+ &VA1-FLS-00EAD03-E-M2-DWD-0608/87.3
123- &VA1-FLS-00EAD03-E-M2-DWD-0608/87.3
E E
=AP010+F02-X1 13 124 -A07 -X1:5 &VA1-FLS-00EAD03-E-M2-DWD-0608/87.4
=AP010+F02-X1 14 124+ &VA1-FLS-00EAD03-E-M2-DWD-0608/87.4
124- &VA1-FLS-00EAD03-E-M2-DWD-0608/87.4
=AP020+F02-X1 3 125 -A07 -X1:6 &VA1-FLS-00EAD03-E-M2-DWD-0608/87.5
=AP020+F02-X1 4 125+ &VA1-FLS-00EAD03-E-M2-DWD-0608/87.5
125- &VA1-FLS-00EAD03-E-M2-DWD-0608/87.5
=AP020+F02-X10 2 126 -A07 -X1:7 &VA1-FLS-00EAD03-E-M2-DWD-0608/87.6
=AP020+F02-X10 1 126+ &VA1-FLS-00EAD03-E-M2-DWD-0608/87.6
F F
126- &VA1-FLS-00EAD03-E-M2-DWD-0608/87.6
=AP020+F02-X10 4 127 -A07 -X1:8 &VA1-FLS-00EAD03-E-M2-DWD-0608/87.7
=AP020+F02-X10 3 127+ &VA1-FLS-00EAD03-E-M2-DWD-0608/87.7
127- &VA1-FLS-00EAD03-E-M2-DWD-0608/87.7
=AP020+F02-X1 13 128 -A07 -X1:9 &VA1-FLS-00EAD03-E-M2-DWD-0608/87.7
=AP020+F02-X1 14 128+ &VA1-FLS-00EAD03-E-M2-DWD-0608/87.7
128- &VA1-FLS-00EAD03-E-M2-DWD-0608/87.8
129 &VA1-FLS-00EAD03-E-M2-DWD-0608/87.8
G G
249 251
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+F04-X10 + F04
Appr. VUNG ANG Page 250
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=EH001+F04-X10
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
129+ &VA1-FLS-00EAD03-E-M2-DWD-0608/87.8
129- &VA1-FLS-00EAD03-E-M2-DWD-0608/87.8
130 &VA1-FLS-00EAD03-E-M2-DWD-0608/87.9
C C
130+ &VA1-FLS-00EAD03-E-M2-DWD-0608/87.9
130- &VA1-FLS-00EAD03-E-M2-DWD-0608/87.9
131 -A07 -X1:12 &VA1-FLS-00EAD03-E-M2-DWD-0608/88.1
131+ &VA1-FLS-00EAD03-E-M2-DWD-0608/88.1
131- &VA1-FLS-00EAD03-E-M2-DWD-0608/88.2
132 -A07 -X1:13 &VA1-FLS-00EAD03-E-M2-DWD-0608/88.2
132+ &VA1-FLS-00EAD03-E-M2-DWD-0608/88.2
132- &VA1-FLS-00EAD03-E-M2-DWD-0608/88.2
D D
133 -A07 -X1:14 &VA1-FLS-00EAD03-E-M2-DWD-0608/88.3
133+ &VA1-FLS-00EAD03-E-M2-DWD-0608/88.3
133- &VA1-FLS-00EAD03-E-M2-DWD-0608/88.3
134 -A07 -X1:15 &VA1-FLS-00EAD03-E-M2-DWD-0608/88.4
134+ &VA1-FLS-00EAD03-E-M2-DWD-0608/88.4
134- &VA1-FLS-00EAD03-E-M2-DWD-0608/88.4
135 -A07 -X1:16 &VA1-FLS-00EAD03-E-M2-DWD-0608/88.5
135+ &VA1-FLS-00EAD03-E-M2-DWD-0608/88.5
E E
135- &VA1-FLS-00EAD03-E-M2-DWD-0608/88.5
136 -A07 -X1:17 &VA1-FLS-00EAD03-E-M2-DWD-0608/88.6
136+ &VA1-FLS-00EAD03-E-M2-DWD-0608/88.6
136- &VA1-FLS-00EAD03-E-M2-DWD-0608/88.6
137 -A07 -X1:18 &VA1-FLS-00EAD03-E-M2-DWD-0608/88.7
137+ &VA1-FLS-00EAD03-E-M2-DWD-0608/88.7
137- &VA1-FLS-00EAD03-E-M2-DWD-0608/88.7
138 -A07 -X1:19 &VA1-FLS-00EAD03-E-M2-DWD-0608/88.7
F F
138+ &VA1-FLS-00EAD03-E-M2-DWD-0608/88.7
138- &VA1-FLS-00EAD03-E-M2-DWD-0608/88.8
139 &VA1-FLS-00EAD03-E-M2-DWD-0608/88.8
139+ &VA1-FLS-00EAD03-E-M2-DWD-0608/88.8
-A07 -X1:20 139- &VA1-FLS-00EAD03-E-M2-DWD-0608/88.8
140 &VA1-FLS-00EAD03-E-M2-DWD-0608/88.9
140+ &VA1-FLS-00EAD03-E-M2-DWD-0608/88.9
140- &VA1-FLS-00EAD03-E-M2-DWD-0608/88.9
G G
250 252
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+F04-X10 + F04
Appr. VUNG ANG Page 251
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4088
-4087
Strip
Cable name
Cable name
==00EAD03=EH001+F04-X10
H05VV5-F
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
=AE004+F02-X1 3 141 -A07 -X1:22 &VA1-FLS-00EAD03-E-M2-DWD-0608/89.1
=AE004+F02-X1 4 141+ =GR001-X4 19 &VA1-FLS-00EAD03-E-M2-DWD-0608/89.1
141- =GR001-X4 20 &VA1-FLS-00EAD03-E-M2-DWD-0608/89.2
C C
=AE004+F02-X10 2 142 -A07 -X1:23 &VA1-FLS-00EAD03-E-M2-DWD-0608/89.2
=AE004+F02-X10 1 142+ &VA1-FLS-00EAD03-E-M2-DWD-0608/89.2
142- &VA1-FLS-00EAD03-E-M2-DWD-0608/89.2
=AE004+F02-X10 4 143 -A07 -X1:24 &VA1-FLS-00EAD03-E-M2-DWD-0608/89.3
=AE004+F02-X10 3 143+ &VA1-FLS-00EAD03-E-M2-DWD-0608/89.3
143- &VA1-FLS-00EAD03-E-M2-DWD-0608/89.3
=AE004+F02-X1 13 144 -A07 -X1:25 &VA1-FLS-00EAD03-E-M2-DWD-0608/89.4
=AE004+F02-X1 14 144+ &VA1-FLS-00EAD03-E-M2-DWD-0608/89.4
D D
144- &VA1-FLS-00EAD03-E-M2-DWD-0608/89.4
=AE004+F02-X10 6 145 -A07 -X1:26 &VA1-FLS-00EAD03-E-M2-DWD-0608/89.5
=AE004+F02-X10 5 145+ &VA1-FLS-00EAD03-E-M2-DWD-0608/89.5
145- &VA1-FLS-00EAD03-E-M2-DWD-0608/89.5
=AE004+X-E001 42 146 -A07 -X1:27 &VA1-FLS-00EAD03-E-M2-DWD-0608/89.6
=AE004+X-E001 41 146+ &VA1-FLS-00EAD03-E-M2-DWD-0608/89.6
146- &VA1-FLS-00EAD03-E-M2-DWD-0608/89.6
1 =CG140-S001 11 147 -A07 -X1:28 &VA1-FLS-00EAD03-E-M2-DWD-0608/89.7
E E
2 =CG140-S001 14 147+ &VA1-FLS-00EAD03-E-M2-DWD-0608/89.7
147- &VA1-FLS-00EAD03-E-M2-DWD-0608/89.7
3 =CG140-S002 21 148 -A07 -X1:29 &VA1-FLS-00EAD03-E-M2-DWD-0608/89.7
4 =CG140-S002 24 148+ &VA1-FLS-00EAD03-E-M2-DWD-0608/89.7
148- &VA1-FLS-00EAD03-E-M2-DWD-0608/89.8
149 &VA1-FLS-00EAD03-E-M2-DWD-0608/89.8
149+ &VA1-FLS-00EAD03-E-M2-DWD-0608/89.8
149- &VA1-FLS-00EAD03-E-M2-DWD-0608/89.8
F F
150 &VA1-FLS-00EAD03-E-M2-DWD-0608/89.9
150+ &VA1-FLS-00EAD03-E-M2-DWD-0608/89.9
150- &VA1-FLS-00EAD03-E-M2-DWD-0608/89.9
1 =CG150-X1 3 151 -A07 -X1:32 &VA1-FLS-00EAD03-E-M2-DWD-0608/90.1
2 =CG150-X1 1 151+ &VA1-FLS-00EAD03-E-M2-DWD-0608/90.1
3 =CG150-X1 2 151- &VA1-FLS-00EAD03-E-M2-DWD-0608/90.1
4 =CG150-X1 4 152 -A07 -X1:33 &VA1-FLS-00EAD03-E-M2-DWD-0608/90.2
152+ &VA1-FLS-00EAD03-E-M2-DWD-0608/90.2
G G
251 253
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+F04-X10 + F04
Appr. VUNG ANG Page 252
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4093
-4092
-4091
-4090
-4089
Strip
Cable name
Cable name
==00EAD03=EH001+F04-X10
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
152- &VA1-FLS-00EAD03-E-M2-DWD-0608/90.2
1 =CG152-X1 3 153 -A07 -X1:34 &VA1-FLS-00EAD03-E-M2-DWD-0608/90.3
2 =CG152-X1 1 153+ &VA1-FLS-00EAD03-E-M2-DWD-0608/90.3
C C
3 =CG152-X1 2 153- &VA1-FLS-00EAD03-E-M2-DWD-0608/90.3
4 =CG152-X1 4 154 -A07 -X1:35 &VA1-FLS-00EAD03-E-M2-DWD-0608/90.4
154+ &VA1-FLS-00EAD03-E-M2-DWD-0608/90.4
154- &VA1-FLS-00EAD03-E-M2-DWD-0608/90.4
1 =CG154-X1 3 155 -A07 -X1:36 &VA1-FLS-00EAD03-E-M2-DWD-0608/90.5
2 =CG154-X1 1 155+ &VA1-FLS-00EAD03-E-M2-DWD-0608/90.5
3 =CG154-X1 2 155- &VA1-FLS-00EAD03-E-M2-DWD-0608/90.5
4 =CG154-X1 4 156 -A07 -X1:37 &VA1-FLS-00EAD03-E-M2-DWD-0608/90.6
D D
156+ &VA1-FLS-00EAD03-E-M2-DWD-0608/90.6
156- &VA1-FLS-00EAD03-E-M2-DWD-0608/90.6
1 =CG156-X1 3 157 -A07 -X1:38 &VA1-FLS-00EAD03-E-M2-DWD-0608/90.7
2 =CG156-X1 1 157+ &VA1-FLS-00EAD03-E-M2-DWD-0608/90.6
3 =CG156-X1 2 157- &VA1-FLS-00EAD03-E-M2-DWD-0608/90.7
4 =CG156-X1 4 158 -A07 -X1:39 &VA1-FLS-00EAD03-E-M2-DWD-0608/90.7
158+ &VA1-FLS-00EAD03-E-M2-DWD-0608/90.7
158- &VA1-FLS-00EAD03-E-M2-DWD-0608/90.7
E E
159 &VA1-FLS-00EAD03-E-M2-DWD-0608/90.8
159+ &VA1-FLS-00EAD03-E-M2-DWD-0608/90.8
-A07 -X1:40 159- &VA1-FLS-00EAD03-E-M2-DWD-0608/90.8
160 &VA1-FLS-00EAD03-E-M2-DWD-0608/90.9
160+ &VA1-FLS-00EAD03-E-M2-DWD-0608/90.9
160- &VA1-FLS-00EAD03-E-M2-DWD-0608/90.9
=AH001+F02-7-F01 14 161 -A08 -X1:2 &VA1-FLS-00EAD03-E-M2-DWD-0608/91.1
=AH001+F02-7-F01 13 161+ =GR001-X4 21 &VA1-FLS-00EAD03-E-M2-DWD-0608/91.1
F F
161- =GR001-X4 22 &VA1-FLS-00EAD03-E-M2-DWD-0608/91.2
1 =AH001+X-A01 3 162 -A08 -X1:3 &VA1-FLS-00EAD03-E-M2-DWD-0608/91.2
2 =AH001+X-A01 1 162+ &VA1-FLS-00EAD03-E-M2-DWD-0608/91.2
162- &VA1-FLS-00EAD03-E-M2-DWD-0608/91.2
3 =AH001+X-A01 6 163 -A08 -X1:4 &VA1-FLS-00EAD03-E-M2-DWD-0608/91.3
163+ &VA1-FLS-00EAD03-E-M2-DWD-0608/91.3
163- &VA1-FLS-00EAD03-E-M2-DWD-0608/91.3
1 +X-S001 14 164 -A08 -X1:5 &VA1-FLS-00EAD03-E-M2-DWD-0608/91.4
G G
252 254
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+F04-X10 + F04
Appr. VUNG ANG Page 253
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4096
-4095
-4094
-4093
Strip
Cable name
Cable name
==00EAD03=EH001+F04-X10
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
2 +X-S001 13 164+ &VA1-FLS-00EAD03-E-M2-DWD-0608/91.4
164- &VA1-FLS-00EAD03-E-M2-DWD-0608/91.4
=GQ001+F02-7-F01 14 165 -A08 -X1:6 &VA1-FLS-00EAD03-E-M2-DWD-0608/91.5
C C
=GQ001+F02-7-F01 13 165+ &VA1-FLS-00EAD03-E-M2-DWD-0608/91.5
165- &VA1-FLS-00EAD03-E-M2-DWD-0608/91.5
=GR001-F012 14 166 -A08 -X1:7 &VA1-FLS-00EAD03-E-M2-DWD-0608/91.6
=GR001-F012 13 166+ &VA1-FLS-00EAD03-E-M2-DWD-0608/91.6
166- &VA1-FLS-00EAD03-E-M2-DWD-0608/91.6
=AE004+F02-X1 5 167 -A08 -X1:8 &VA1-FLS-00EAD03-E-M2-DWD-0608/91.7
=AE004+F02-X1 8 167+ &VA1-FLS-00EAD03-E-M2-DWD-0608/91.7
167- &VA1-FLS-00EAD03-E-M2-DWD-0608/91.7
D D
168 -A08 -X1:9 &VA1-FLS-00EAD03-E-M2-DWD-0608/91.7
168+ &VA1-FLS-00EAD03-E-M2-DWD-0608/91.7
168- &VA1-FLS-00EAD03-E-M2-DWD-0608/91.8
169 &VA1-FLS-00EAD03-E-M2-DWD-0608/91.8
169+ &VA1-FLS-00EAD03-E-M2-DWD-0608/91.8
169- &VA1-FLS-00EAD03-E-M2-DWD-0608/91.8
170 &VA1-FLS-00EAD03-E-M2-DWD-0608/91.9
170+ &VA1-FLS-00EAD03-E-M2-DWD-0608/91.9
E E
170- &VA1-FLS-00EAD03-E-M2-DWD-0608/91.9
=GP001+F02-7-Q001 14 171 -A08 -X1:12 &VA1-FLS-00EAD03-E-M2-DWD-0608/92.1
=GP001+F02-7-Q001 13 171+ &VA1-FLS-00EAD03-E-M2-DWD-0608/92.1
171- &VA1-FLS-00EAD03-E-M2-DWD-0608/92.2
=GP001+F02-7-F005 14 172 -A08 -X1:13 &VA1-FLS-00EAD03-E-M2-DWD-0608/92.2
=GP001+F02-7-F005 13 172+ &VA1-FLS-00EAD03-E-M2-DWD-0608/92.2
172- &VA1-FLS-00EAD03-E-M2-DWD-0608/92.2
1 +X-S002 14 173 -A08 -X1:14 &VA1-FLS-00EAD03-E-M2-DWD-0608/92.3
F F
2 +X-S002 13 173+ &VA1-FLS-00EAD03-E-M2-DWD-0608/92.3
173- &VA1-FLS-00EAD03-E-M2-DWD-0608/92.3
1 +X-S003 14 174 -A08 -X1:15 &VA1-FLS-00EAD03-E-M2-DWD-0608/92.4
2 +X-S003 13 174+ &VA1-FLS-00EAD03-E-M2-DWD-0608/92.4
174- &VA1-FLS-00EAD03-E-M2-DWD-0608/92.4
1 +X-S004 14 175 -A08 -X1:16 &VA1-FLS-00EAD03-E-M2-DWD-0608/92.5
2 +X-S004 13 175+ &VA1-FLS-00EAD03-E-M2-DWD-0608/92.5
175- &VA1-FLS-00EAD03-E-M2-DWD-0608/92.5
G G
253 255
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+F04-X10 + F04
Appr. VUNG ANG Page 254
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4065
-4064
-4063
-4062
-4061
-4060
-4059
Strip
Cable name
Cable name
==00EAD03=EH001+F04-X10
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
176 -A08 -X1:17 &VA1-FLS-00EAD03-E-M2-DWD-0608/92.6
176+ &VA1-FLS-00EAD03-E-M2-DWD-0608/92.6
176- &VA1-FLS-00EAD03-E-M2-DWD-0608/92.6
C C
177 -A08 -X1:18 &VA1-FLS-00EAD03-E-M2-DWD-0608/92.7
177+ &VA1-FLS-00EAD03-E-M2-DWD-0608/92.7
177- &VA1-FLS-00EAD03-E-M2-DWD-0608/92.7
178 -A08 -X1:19 &VA1-FLS-00EAD03-E-M2-DWD-0608/92.7
178+ &VA1-FLS-00EAD03-E-M2-DWD-0608/92.7
178- &VA1-FLS-00EAD03-E-M2-DWD-0608/92.8
179 &VA1-FLS-00EAD03-E-M2-DWD-0608/92.8
179+ &VA1-FLS-00EAD03-E-M2-DWD-0608/92.8
D D
-A08 -X1:20 179- &VA1-FLS-00EAD03-E-M2-DWD-0608/92.8
180 &VA1-FLS-00EAD03-E-M2-DWD-0608/92.9
180+ &VA1-FLS-00EAD03-E-M2-DWD-0608/92.9
180- &VA1-FLS-00EAD03-E-M2-DWD-0608/92.9
1 =CH102+X-S001 14 181 -A08 -X1:22 &VA1-FLS-00EAD03-E-M2-DWD-0608/93.1
2 =CH102+X-S001 13 181+ =GR001-X4 23 &VA1-FLS-00EAD03-E-M2-DWD-0608/93.1
181- =GR001-X4 24 &VA1-FLS-00EAD03-E-M2-DWD-0608/93.2
1 =CH112+X-S002 14 182 -A08 -X1:23 &VA1-FLS-00EAD03-E-M2-DWD-0608/93.2
E E
2 =CH112+X-S002 13 182+ &VA1-FLS-00EAD03-E-M2-DWD-0608/93.2
182- &VA1-FLS-00EAD03-E-M2-DWD-0608/93.2
1 =CH113+X-S003 14 183 -A08 -X1:24 &VA1-FLS-00EAD03-E-M2-DWD-0608/93.3
2 =CH113+X-S003 13 183+ &VA1-FLS-00EAD03-E-M2-DWD-0608/93.3
183- &VA1-FLS-00EAD03-E-M2-DWD-0608/93.3
1 =CH114+X-S004 14 184 -A08 -X1:25 &VA1-FLS-00EAD03-E-M2-DWD-0608/93.4
2 =CH114+X-S004 13 184+ &VA1-FLS-00EAD03-E-M2-DWD-0608/93.4
184- &VA1-FLS-00EAD03-E-M2-DWD-0608/93.4
F F
1 =CH115+X-S005 14 185 -A08 -X1:26 &VA1-FLS-00EAD03-E-M2-DWD-0608/93.5
2 =CH115+X-S005 13 185+ &VA1-FLS-00EAD03-E-M2-DWD-0608/93.5
185- &VA1-FLS-00EAD03-E-M2-DWD-0608/93.5
1 =CH122+X-S006 14 186 -A08 -X1:27 &VA1-FLS-00EAD03-E-M2-DWD-0608/93.6
2 =CH122+X-S006 13 186+ &VA1-FLS-00EAD03-E-M2-DWD-0608/93.6
186- &VA1-FLS-00EAD03-E-M2-DWD-0608/93.6
1 +LC01-X4 8 187 -A08 -X1:28 &VA1-FLS-00EAD03-E-M2-DWD-0608/93.7
2 +LC01-X4 7 187+ &VA1-FLS-00EAD03-E-M2-DWD-0608/93.7
G G
254 256
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+F04-X10 + F04
Appr. VUNG ANG Page 255
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=EH001+F04-X10
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
187- &VA1-FLS-00EAD03-E-M2-DWD-0608/93.7
=CH102+F03-A001 64 188 -A08 -X1:29 &VA1-FLS-00EAD03-E-M2-DWD-0608/93.7
=CH102+F03-A001 63 188+ &VA1-FLS-00EAD03-E-M2-DWD-0608/93.7
C C
188- &VA1-FLS-00EAD03-E-M2-DWD-0608/93.8
189 &VA1-FLS-00EAD03-E-M2-DWD-0608/93.8
189+ &VA1-FLS-00EAD03-E-M2-DWD-0608/93.8
189- &VA1-FLS-00EAD03-E-M2-DWD-0608/93.8
190 &VA1-FLS-00EAD03-E-M2-DWD-0608/93.9
190+ &VA1-FLS-00EAD03-E-M2-DWD-0608/93.9
190- &VA1-FLS-00EAD03-E-M2-DWD-0608/93.9
=GR001-F001 14 191 -A08 -X1:32 &VA1-FLS-00EAD03-E-M2-DWD-0608/94.1
D D
=GR001-F001 13 191+ =GR001-X4 25 &VA1-FLS-00EAD03-E-M2-DWD-0608/94.1
191- =GR001-X4 26 &VA1-FLS-00EAD03-E-M2-DWD-0608/94.2
=GR001-F002 14 192 -A08 -X1:33 &VA1-FLS-00EAD03-E-M2-DWD-0608/94.2
=GR001-F002 13 192+ &VA1-FLS-00EAD03-E-M2-DWD-0608/94.2
192- &VA1-FLS-00EAD03-E-M2-DWD-0608/94.2
=GR001-F003 14 193 -A08 -X1:34 &VA1-FLS-00EAD03-E-M2-DWD-0608/94.3
=GR001-F003 13 193+ &VA1-FLS-00EAD03-E-M2-DWD-0608/94.3
193- &VA1-FLS-00EAD03-E-M2-DWD-0608/94.3
E E
=GR001-F004 14 194 -A08 -X1:35 &VA1-FLS-00EAD03-E-M2-DWD-0608/94.4
=GR001-F004 13 194+ &VA1-FLS-00EAD03-E-M2-DWD-0608/94.4
194- &VA1-FLS-00EAD03-E-M2-DWD-0608/94.4
=GR001-F005 14 195 -A08 -X1:36 &VA1-FLS-00EAD03-E-M2-DWD-0608/94.5
=GR001-F005 13 195+ &VA1-FLS-00EAD03-E-M2-DWD-0608/94.5
195- &VA1-FLS-00EAD03-E-M2-DWD-0608/94.5
=GR001-F006 14 196 -A08 -X1:37 &VA1-FLS-00EAD03-E-M2-DWD-0608/94.6
=GR001-F006 13 196+ &VA1-FLS-00EAD03-E-M2-DWD-0608/94.6
F F
196- &VA1-FLS-00EAD03-E-M2-DWD-0608/94.6
=GR001-F007 14 197 -A08 -X1:38 &VA1-FLS-00EAD03-E-M2-DWD-0608/94.7
=GR001-F007 13 197+ &VA1-FLS-00EAD03-E-M2-DWD-0608/94.7
197- &VA1-FLS-00EAD03-E-M2-DWD-0608/94.7
=GR001-F008 14 198 -A08 -X1:39 &VA1-FLS-00EAD03-E-M2-DWD-0608/94.7
=GR001-F008 13 198+ &VA1-FLS-00EAD03-E-M2-DWD-0608/94.7
198- &VA1-FLS-00EAD03-E-M2-DWD-0608/94.8
199 &VA1-FLS-00EAD03-E-M2-DWD-0608/94.8
G G
255 257
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+F04-X10 + F04
Appr. VUNG ANG Page 256
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=EH001+F04-X10
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
199+ &VA1-FLS-00EAD03-E-M2-DWD-0608/94.8
-A08 -X1:40 199- &VA1-FLS-00EAD03-E-M2-DWD-0608/94.8
200 &VA1-FLS-00EAD03-E-M2-DWD-0608/94.9
C C
200+ &VA1-FLS-00EAD03-E-M2-DWD-0608/94.9
200- &VA1-FLS-00EAD03-E-M2-DWD-0608/94.9
=GR001-F009 14 201 -A09 -X1:2 &VA1-FLS-00EAD03-E-M2-DWD-0608/95.1
=GR001-F009 13 201+ &VA1-FLS-00EAD03-E-M2-DWD-0608/95.1
201- &VA1-FLS-00EAD03-E-M2-DWD-0608/95.2
=GR001-F010 14 202 -A09 -X1:3 &VA1-FLS-00EAD03-E-M2-DWD-0608/95.2
=GR001-F010 13 202+ &VA1-FLS-00EAD03-E-M2-DWD-0608/95.2
202- &VA1-FLS-00EAD03-E-M2-DWD-0608/95.2
D D
=GR001-F011 14 203 -A09 -X1:4 &VA1-FLS-00EAD03-E-M2-DWD-0608/95.3
=GR001-F011 13 203+ &VA1-FLS-00EAD03-E-M2-DWD-0608/95.3
203- &VA1-FLS-00EAD03-E-M2-DWD-0608/95.3
=GR001-F013 14 204 -A09 -X1:5 &VA1-FLS-00EAD03-E-M2-DWD-0608/95.4
=GR001-F013 13 204+ &VA1-FLS-00EAD03-E-M2-DWD-0608/95.4
204- &VA1-FLS-00EAD03-E-M2-DWD-0608/95.4
=GR001-F014 14 205 -A09 -X1:6 &VA1-FLS-00EAD03-E-M2-DWD-0608/95.5
=GR001-F014 13 205+ &VA1-FLS-00EAD03-E-M2-DWD-0608/95.5
E E
205- &VA1-FLS-00EAD03-E-M2-DWD-0608/95.5
=GR001-F015 14 206 -A09 -X1:7 &VA1-FLS-00EAD03-E-M2-DWD-0608/95.6
=GR001-F015 13 206+ &VA1-FLS-00EAD03-E-M2-DWD-0608/95.6
206- &VA1-FLS-00EAD03-E-M2-DWD-0608/95.6
=GR001-F016 14 207 -A09 -X1:8 &VA1-FLS-00EAD03-E-M2-DWD-0608/95.7
=GR001-F016 13 207+ &VA1-FLS-00EAD03-E-M2-DWD-0608/95.7
207- &VA1-FLS-00EAD03-E-M2-DWD-0608/95.7
=GR001-F017 14 208 -A09 -X1:9 &VA1-FLS-00EAD03-E-M2-DWD-0608/95.7
F F
=GR001-F017 13 208+ &VA1-FLS-00EAD03-E-M2-DWD-0608/95.7
208- &VA1-FLS-00EAD03-E-M2-DWD-0608/95.8
209 &VA1-FLS-00EAD03-E-M2-DWD-0608/95.8
209+ &VA1-FLS-00EAD03-E-M2-DWD-0608/95.8
209- &VA1-FLS-00EAD03-E-M2-DWD-0608/95.8
210 &VA1-FLS-00EAD03-E-M2-DWD-0608/95.9
210+ &VA1-FLS-00EAD03-E-M2-DWD-0608/95.9
210- &VA1-FLS-00EAD03-E-M2-DWD-0608/95.9
G G
256 258
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+F04-X10 + F04
Appr. VUNG ANG Page 257
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4097
Strip
Cable name
Cable name
==00EAD03=EH001+F04-X10
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
=GR001-F018 14 211 -A09 -X1:12 &VA1-FLS-00EAD03-E-M2-DWD-0608/96.1
=GR001-F018 13 211+ &VA1-FLS-00EAD03-E-M2-DWD-0608/96.1
211- &VA1-FLS-00EAD03-E-M2-DWD-0608/96.2
C C
=GR001-F019 14 212 -A09 -X1:13 &VA1-FLS-00EAD03-E-M2-DWD-0608/96.2
=GR001-F019 13 212+ &VA1-FLS-00EAD03-E-M2-DWD-0608/96.2
212- &VA1-FLS-00EAD03-E-M2-DWD-0608/96.2
=GR001-F020 14 213 -A09 -X1:14 &VA1-FLS-00EAD03-E-M2-DWD-0608/96.3
=GR001-F020 13 213+ &VA1-FLS-00EAD03-E-M2-DWD-0608/96.3
213- &VA1-FLS-00EAD03-E-M2-DWD-0608/96.3
=GR001-F021 14 214 -A09 -X1:15 &VA1-FLS-00EAD03-E-M2-DWD-0608/96.4
=GR001-F021 13 214+ &VA1-FLS-00EAD03-E-M2-DWD-0608/96.4
D D
214- &VA1-FLS-00EAD03-E-M2-DWD-0608/96.4
-A200 F2 215 -A09 -X1:16 &VA1-FLS-00EAD03-E-M2-DWD-0608/96.5
-A200 F1 215+ &VA1-FLS-00EAD03-E-M2-DWD-0608/96.5
215- &VA1-FLS-00EAD03-E-M2-DWD-0608/96.5
1 +LC01-X4 10 216 -A09 -X1:17 &VA1-FLS-00EAD03-E-M2-DWD-0608/96.6
2 +LC01-X4 9 216+ &VA1-FLS-00EAD03-E-M2-DWD-0608/96.6
216- &VA1-FLS-00EAD03-E-M2-DWD-0608/96.6
3 +LC01-X4 12 217 -A09 -X1:18 &VA1-FLS-00EAD03-E-M2-DWD-0608/96.7
E E
4 +LC01-X4 11 217+ &VA1-FLS-00EAD03-E-M2-DWD-0608/96.7
217- &VA1-FLS-00EAD03-E-M2-DWD-0608/96.7
218 -A09 -X1:19 &VA1-FLS-00EAD03-E-M2-DWD-0608/96.7
218+ &VA1-FLS-00EAD03-E-M2-DWD-0608/96.7
218- &VA1-FLS-00EAD03-E-M2-DWD-0608/96.8
219 &VA1-FLS-00EAD03-E-M2-DWD-0608/96.8
219+ &VA1-FLS-00EAD03-E-M2-DWD-0608/96.8
-A09 -X1:20 219- &VA1-FLS-00EAD03-E-M2-DWD-0608/96.8
F F
220 &VA1-FLS-00EAD03-E-M2-DWD-0608/96.9
220+ &VA1-FLS-00EAD03-E-M2-DWD-0608/96.9
220- &VA1-FLS-00EAD03-E-M2-DWD-0608/96.9
221 -A09 -X1:22 &VA1-FLS-00EAD03-E-M2-DWD-0608/97.1
221+ &VA1-FLS-00EAD03-E-M2-DWD-0608/97.1
221- &VA1-FLS-00EAD03-E-M2-DWD-0608/97.2
222 -A09 -X1:23 &VA1-FLS-00EAD03-E-M2-DWD-0608/97.2
222+ &VA1-FLS-00EAD03-E-M2-DWD-0608/97.2
G G
257 259
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+F04-X10 + F04
Appr. VUNG ANG Page 258
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=EH001+F04-X10
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
222- &VA1-FLS-00EAD03-E-M2-DWD-0608/97.2
223 -A09 -X1:24 &VA1-FLS-00EAD03-E-M2-DWD-0608/97.3
223+ &VA1-FLS-00EAD03-E-M2-DWD-0608/97.3
C C
223- &VA1-FLS-00EAD03-E-M2-DWD-0608/97.3
224 -A09 -X1:25 &VA1-FLS-00EAD03-E-M2-DWD-0608/97.4
224+ &VA1-FLS-00EAD03-E-M2-DWD-0608/97.4
224- &VA1-FLS-00EAD03-E-M2-DWD-0608/97.4
225 -A09 -X1:26 &VA1-FLS-00EAD03-E-M2-DWD-0608/97.5
225+ &VA1-FLS-00EAD03-E-M2-DWD-0608/97.5
225- &VA1-FLS-00EAD03-E-M2-DWD-0608/97.5
226 -A09 -X1:27 &VA1-FLS-00EAD03-E-M2-DWD-0608/97.6
D D
226+ &VA1-FLS-00EAD03-E-M2-DWD-0608/97.6
226- &VA1-FLS-00EAD03-E-M2-DWD-0608/97.6
227 -A09 -X1:28 &VA1-FLS-00EAD03-E-M2-DWD-0608/97.7
227+ &VA1-FLS-00EAD03-E-M2-DWD-0608/97.7
227- &VA1-FLS-00EAD03-E-M2-DWD-0608/97.7
228 -A09 -X1:29 &VA1-FLS-00EAD03-E-M2-DWD-0608/97.7
228+ &VA1-FLS-00EAD03-E-M2-DWD-0608/97.7
228- &VA1-FLS-00EAD03-E-M2-DWD-0608/97.8
E E
229 &VA1-FLS-00EAD03-E-M2-DWD-0608/97.8
229+ &VA1-FLS-00EAD03-E-M2-DWD-0608/97.8
229- &VA1-FLS-00EAD03-E-M2-DWD-0608/97.8
230 &VA1-FLS-00EAD03-E-M2-DWD-0608/97.9
230+ &VA1-FLS-00EAD03-E-M2-DWD-0608/97.9
230- &VA1-FLS-00EAD03-E-M2-DWD-0608/97.9
231 -A09 -X1:32 &VA1-FLS-00EAD03-E-M2-DWD-0608/98.1
231+ &VA1-FLS-00EAD03-E-M2-DWD-0608/98.1
F F
231- &VA1-FLS-00EAD03-E-M2-DWD-0608/98.2
232 -A09 -X1:33 &VA1-FLS-00EAD03-E-M2-DWD-0608/98.2
232+ &VA1-FLS-00EAD03-E-M2-DWD-0608/98.2
232- &VA1-FLS-00EAD03-E-M2-DWD-0608/98.2
233 -A09 -X1:34 &VA1-FLS-00EAD03-E-M2-DWD-0608/98.3
233+ &VA1-FLS-00EAD03-E-M2-DWD-0608/98.3
233- &VA1-FLS-00EAD03-E-M2-DWD-0608/98.3
234 -A09 -X1:35 &VA1-FLS-00EAD03-E-M2-DWD-0608/98.4
G G
258 260
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+F04-X10 + F04
Appr. VUNG ANG Page 259
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=EH001+F04-X10
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
234+ &VA1-FLS-00EAD03-E-M2-DWD-0608/98.4
234- &VA1-FLS-00EAD03-E-M2-DWD-0608/98.4
235 -A09 -X1:36 &VA1-FLS-00EAD03-E-M2-DWD-0608/98.5
C C
235+ &VA1-FLS-00EAD03-E-M2-DWD-0608/98.5
235- &VA1-FLS-00EAD03-E-M2-DWD-0608/98.5
236 -A09 -X1:37 &VA1-FLS-00EAD03-E-M2-DWD-0608/98.6
236+ &VA1-FLS-00EAD03-E-M2-DWD-0608/98.6
236- &VA1-FLS-00EAD03-E-M2-DWD-0608/98.6
237 -A09 -X1:38 &VA1-FLS-00EAD03-E-M2-DWD-0608/98.7
237+ &VA1-FLS-00EAD03-E-M2-DWD-0608/98.7
237- &VA1-FLS-00EAD03-E-M2-DWD-0608/98.7
D D
+F02-7-X4 11 238 -A09 -X1:39 &VA1-FLS-00EAD03-E-M2-DWD-0608/98.7
238+ &VA1-FLS-00EAD03-E-M2-DWD-0608/98.8
238- &VA1-FLS-00EAD03-E-M2-DWD-0608/98.8
239 &VA1-FLS-00EAD03-E-M2-DWD-0608/98.8
239+ &VA1-FLS-00EAD03-E-M2-DWD-0608/98.8
-A09 -X1:40 239- &VA1-FLS-00EAD03-E-M2-DWD-0608/98.8
240 &VA1-FLS-00EAD03-E-M2-DWD-0608/98.9
240+ &VA1-FLS-00EAD03-E-M2-DWD-0608/98.9
E E
240- &VA1-FLS-00EAD03-E-M2-DWD-0608/98.9
F F
G G
259 261
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+F04-X10 + F04
Appr. VUNG ANG Page 260
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4100
-4099
-4098
Strip
Cable name
Cable name
==00EAD03=EH001+F04-X11
H05VVC4V5-K
H05VVC4V5-K
H05VVC4V5-K
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
=GR001-X4 27 1 -A12 -X1:1 &VA1-FLS-00EAD03-E-M2-DWD-0608/99.1
1 =CG003+X-B01 I+ 2 -A12 -X1:2 &VA1-FLS-00EAD03-E-M2-DWD-0608/99.1
2 =CG003+X-B01 I- 3 -A12 -X1:3 &VA1-FLS-00EAD03-E-M2-DWD-0608/99.2
C C
1 =CG004+X-B02 I+ 4 -A12 -X1:4 &VA1-FLS-00EAD03-E-M2-DWD-0608/99.3
2 =CG004+X-B02 I- 5 -A12 -X1:5 &VA1-FLS-00EAD03-E-M2-DWD-0608/99.4
1 =CG005+X-B03 I+ 6 -A12 -X1:6 &VA1-FLS-00EAD03-E-M2-DWD-0608/99.5
2 =CG005+X-B03 I- 7 -A12 -X1:7 &VA1-FLS-00EAD03-E-M2-DWD-0608/99.6
8 -A12 -X1:8 &VA1-FLS-00EAD03-E-M2-DWD-0608/99.7
9 -A12 -X1:9 &VA1-FLS-00EAD03-E-M2-DWD-0608/99.8
10 -A12 -X1:10 &VA1-FLS-00EAD03-E-M2-DWD-0608/99.8
11 -A12 -X1:11 &VA1-FLS-00EAD03-E-M2-DWD-0608/100.1
D D
=AE002-X4 8 12 -A12 -X1:12 &VA1-FLS-00EAD03-E-M2-DWD-0608/100.1
13 -A12 -X1:13 &VA1-FLS-00EAD03-E-M2-DWD-0608/100.2
=AE002-X4 12 14 -A12 -X1:14 &VA1-FLS-00EAD03-E-M2-DWD-0608/100.3
15 -A12 -X1:15 &VA1-FLS-00EAD03-E-M2-DWD-0608/100.4
=AE002-X4 15 16 -A12 -X1:16 &VA1-FLS-00EAD03-E-M2-DWD-0608/100.5
17 -A12 -X1:17 &VA1-FLS-00EAD03-E-M2-DWD-0608/100.6
=AE002-X4 17 18 -A12 -X1:18 &VA1-FLS-00EAD03-E-M2-DWD-0608/100.7
19 -A12 -X1:19 &VA1-FLS-00EAD03-E-M2-DWD-0608/100.8
E E
=GR001-X4 28 20 -A12 -X1:20 &VA1-FLS-00EAD03-E-M2-DWD-0608/100.8
PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608/99.3
PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608/99.4
PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608/99.6
PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608/99.8
PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608/100.3
PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608/100.4
PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608/100.6
F F
PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608/100.8
G G
260 262
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+F04-X11 + F04
Appr. VUNG ANG Page 261
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=EH001+F04-X20
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
-A10 -X1:2 1 ==00EAC03=AF001+F01-5-X20 1 &VA1-FLS-00EAD03-E-M2-DWD-0608/101.1
-A10 -X1:3 2 ==00EAC03=AF001-K001 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608/101.2
-A10 -X1:4 3 ==00EAC03=AF001+F01-5-X20 3 &VA1-FLS-00EAD03-E-M2-DWD-0608/101.3
C C
-A10 -X1:5 4 =AE001+F01-2-X20 1 &VA1-FLS-00EAD03-E-M2-DWD-0608/101.4
-A10 -X1:6 5 =AE002-K004 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608/101.5
-A10 -X1:7 6 =AP010-K005 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608/101.6
-A10 -X1:8 7 =AP020-K006 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608/101.7
-A10 -X1:9 8 =AE004-K007 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608/101.7
==00EAC03=AF001+F01-5-X20 2 9 =GR001-X4 30 &VA1-FLS-00EAD03-E-M2-DWD-0608/101.1
==00EAC03=AF001-K001 A2 10 &VA1-FLS-00EAD03-E-M2-DWD-0608/101.2
==00EAC03=AF001+F01-5-X20 4 11 &VA1-FLS-00EAD03-E-M2-DWD-0608/101.3
D D
=AE001+F01-2-X20 2 12 &VA1-FLS-00EAD03-E-M2-DWD-0608/101.4
=AE002-K004 A2 13 &VA1-FLS-00EAD03-E-M2-DWD-0608/101.5
=AP010-K005 A2 14 &VA1-FLS-00EAD03-E-M2-DWD-0608/101.6
=AP020-K006 A2 15 &VA1-FLS-00EAD03-E-M2-DWD-0608/101.7
=AE004-K007 A2 16 &VA1-FLS-00EAD03-E-M2-DWD-0608/101.7
-A10 -X1:1 17 =GR001-X4 29 &VA1-FLS-00EAD03-E-M2-DWD-0608/101.0
-A10 -X1:10 18 &VA1-FLS-00EAD03-E-M2-DWD-0608/101.8
-A10 -X1:12 19 -K010 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608/102.1
E E
-A10 -X1:13 20 -K011 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608/102.2
-A10 -X1:14 21 -K012 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608/102.3
-A10 -X1:15 22 -K013 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608/102.4
-A10 -X1:16 23 -K014 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608/102.5
-A10 -X1:17 24 -K015 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608/102.6
-A10 -X1:18 25 -K016 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608/102.7
-A10 -X1:19 26 -K017 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608/102.7
-K010 A2 27 &VA1-FLS-00EAD03-E-M2-DWD-0608/102.1
F F
-K011 A2 28 &VA1-FLS-00EAD03-E-M2-DWD-0608/102.2
-K012 A2 29 &VA1-FLS-00EAD03-E-M2-DWD-0608/102.3
-K013 A2 30 &VA1-FLS-00EAD03-E-M2-DWD-0608/102.4
-K014 A2 31 &VA1-FLS-00EAD03-E-M2-DWD-0608/102.5
-K015 A2 32 &VA1-FLS-00EAD03-E-M2-DWD-0608/102.6
-K016 A2 33 &VA1-FLS-00EAD03-E-M2-DWD-0608/102.7
-K017 A2 34 &VA1-FLS-00EAD03-E-M2-DWD-0608/102.7
-A10 -X1:11 35 &VA1-FLS-00EAD03-E-M2-DWD-0608/102.0
G G
261 263
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+F04-X20 + F04
Appr. VUNG ANG Page 262
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4101
Strip
Cable name
Cable name
==00EAD03=EH001+F04-X20
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
-A10 -X1:20 36 &VA1-FLS-00EAD03-E-M2-DWD-0608/102.8
-A10 -X1:22 37 -K020 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608/103.1
-A10 -X1:23 38 -K021 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608/103.2
C C
-A10 -X1:24 39 -K022 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608/103.3
-A10 -X1:25 40 -K023 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608/103.4
-A10 -X1:26 41 -K024 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608/103.5
-A10 -X1:27 42 -K025 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608/103.6
-A10 -X1:28 43 -K026 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608/103.7
-A10 -X1:29 44 -K027 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608/103.7
-K020 A2 45 &VA1-FLS-00EAD03-E-M2-DWD-0608/103.1
-K021 A2 46 &VA1-FLS-00EAD03-E-M2-DWD-0608/103.2
D D
-K022 A2 47 &VA1-FLS-00EAD03-E-M2-DWD-0608/103.3
-K023 A2 48 &VA1-FLS-00EAD03-E-M2-DWD-0608/103.4
-K024 A2 49 &VA1-FLS-00EAD03-E-M2-DWD-0608/103.5
-K025 A2 50 &VA1-FLS-00EAD03-E-M2-DWD-0608/103.6
-K026 A2 51 &VA1-FLS-00EAD03-E-M2-DWD-0608/103.7
-K027 A2 52 &VA1-FLS-00EAD03-E-M2-DWD-0608/103.7
-A10 -X1:21 53 &VA1-FLS-00EAD03-E-M2-DWD-0608/103.0
-A10 -X1:30 54 &VA1-FLS-00EAD03-E-M2-DWD-0608/103.8
E E
-A10 -X1:32 55 =GP001+F02-7-X20 1 &VA1-FLS-00EAD03-E-M2-DWD-0608/104.1
-A10 -X1:33 56 =GP001+F02-7-X20 3 &VA1-FLS-00EAD03-E-M2-DWD-0608/104.2
-A10 -X1:34 57 -K032 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608/104.3
-A10 -X1:35 58 -K033 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608/104.4
-A10 -X1:36 59 -K034 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608/104.5
1 +X-P001 1 60 -A10 -X1:37 &VA1-FLS-00EAD03-E-M2-DWD-0608/104.6
2 +X-P001 5 61 -A10 -X1:38 &VA1-FLS-00EAD03-E-M2-DWD-0608/104.7
-A10 -X1:39 62 -K037 A1 &VA1-FLS-00EAD03-E-M2-DWD-0608/104.7
F F
=GP001+F02-7-X20 2 63 &VA1-FLS-00EAD03-E-M2-DWD-0608/104.1
=GP001+F02-7-X20 4 64 &VA1-FLS-00EAD03-E-M2-DWD-0608/104.2
-K032 A2 65 &VA1-FLS-00EAD03-E-M2-DWD-0608/104.3
-K033 A2 66 &VA1-FLS-00EAD03-E-M2-DWD-0608/104.4
-K034 A2 67 &VA1-FLS-00EAD03-E-M2-DWD-0608/104.5
3 +X-P001 2 68 &VA1-FLS-00EAD03-E-M2-DWD-0608/104.6
4 +X-P001 6 69 &VA1-FLS-00EAD03-E-M2-DWD-0608/104.7
-K037 A2 70 &VA1-FLS-00EAD03-E-M2-DWD-0608/104.7
G G
262 264
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+F04-X20 + F04
Appr. VUNG ANG Page 263
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=EH001+F04-X20
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
-A10 -X1:31 71 &VA1-FLS-00EAD03-E-M2-DWD-0608/104.0
-A10 -X1:40 72 &VA1-FLS-00EAD03-E-M2-DWD-0608/104.8
C C
D D
E E
F F
G G
263 265
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+F04-X20 + F04
Appr. VUNG ANG Page 264
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=EH001+F04-X21
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
-A13 -X1:1 1 =GR001-X4 31 &VA1-FLS-00EAD03-E-M2-DWD-0608/105.0
-A13 -X1:3 2 =AE002-U1 5 &VA1-FLS-00EAD03-E-M2-DWD-0608/105.2
-A13 -X1:4 3 &VA1-FLS-00EAD03-E-M2-DWD-0608/105.3
C C
-A13 -X1:5 4 &VA1-FLS-00EAD03-E-M2-DWD-0608/105.3
-A13 -X1:6 5 =AE002-U1 6 &VA1-FLS-00EAD03-E-M2-DWD-0608/105.4
-A13 -X1:7 6 &VA1-FLS-00EAD03-E-M2-DWD-0608/105.5
-A13 -X1:8 7 &VA1-FLS-00EAD03-E-M2-DWD-0608/105.5
-A13 -X1:9 8 &VA1-FLS-00EAD03-E-M2-DWD-0608/105.6
-A13 -X1:10 9 &VA1-FLS-00EAD03-E-M2-DWD-0608/105.7
-A13 -X1:20 10 =GR001-X4 32 &VA1-FLS-00EAD03-E-M2-DWD-0608/105.8
D D
E E
F F
G G
264 266
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+F04-X21 + F04
Appr. VUNG ANG Page 265
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4088
Strip
Cable name
Cable name
==00EAD03=CG150+F04-X1
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
2 =EH001-X10 151+ 1 -S001 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001/90.1
3 =EH001-X10 151- 2 -S001 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001/90.1
1 =EH001-X10 151 3 -S001 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001/90.1
C C
4 =EH001-X10 152 4 =CG151-S001 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001/90.2
D D
E E
F F
G G
265 267
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=CG150+F04-X1 + F04
Appr. VUNG ANG Page 266
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4089
Strip
Cable name
Cable name
==00EAD03=CG152+F04-X1
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
2 =EH001-X10 153+ 1 -S001 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001/90.3
3 =EH001-X10 153- 2 -S001 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001/90.3
1 =EH001-X10 153 3 -S001 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001/90.3
C C
4 =EH001-X10 154 4 =CG153-S001 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001/90.4
D D
E E
F F
G G
266 268
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=CG152+F04-X1 + F04
Appr. VUNG ANG Page 267
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4090
Strip
Cable name
Cable name
==00EAD03=CG154+F04-X1
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
2 =EH001-X10 155+ 1 -S001 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001/90.5
3 =EH001-X10 155- 2 -S001 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001/90.5
1 =EH001-X10 155 3 -S001 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001/90.5
C C
4 =EH001-X10 156 4 =CG155-S001 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001/90.6
D D
E E
F F
G G
267 269
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=CG154+F04-X1 + F04
Appr. VUNG ANG Page 268
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4091
Strip
Cable name
Cable name
==00EAD03=CG156+F04-X1
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
2 =EH001-X10 157+ 1 -S001 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001/90.6
3 =EH001-X10 157- 2 -S001 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001/90.7
1 =EH001-X10 157 3 -S001 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001/90.7
C C
4 =EH001-X10 158 4 =CG157-S001 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001/90.7
D D
E E
F F
G G
268 270
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=CG156+F04-X1 + F04
Appr. VUNG ANG Page 269
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4068
-4069
Strip
Cable name
Cable name
==00EAC51=CL101+F04-X4
H05VV5-F
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
1 =CH121+X-S001 11 3 &VA1-FLS-00EAD03-E-M2-DWD-0608/141.3
2 =CH121+X-S001 12 4 &VA1-FLS-00EAD03-E-M2-DWD-0608/141.4
3 =CH122+X-S002 11 3 &VA1-FLS-00EAD03-E-M2-DWD-0608/141.4
C C
4 =CH122+X-S002 12 4 &VA1-FLS-00EAD03-E-M2-DWD-0608/141.4
==00EAD03=EH001-X10 37+ 5 -U001 1 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001/78.7
-U001 2 6 ==00EAD03=EH001-X10 37 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001/78.7
7 -X7 2 &VA1-FLS-00EAD03-E-M2-DWD-0608/141.5
8 -X7 1 &VA1-FLS-00EAD03-E-M2-DWD-0608/141.6
D D
E E
F F
G G
269 271
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAC51=CL101+F04-X4 + F04
Appr. VUNG ANG Page 270
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4001
Strip
Cable name
Cable name
==00EAC51=CL101+F04-X7
H05VVC4V5-K
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
1 +X-B001 1 1 ==00EAD03=GR001-X4 33 &VA1-FLS-00EAD03-E-M2-DWD-0608+/140.4
-X4 8
C C
2
1 +X-B001 2 2 ==00EAD03=GR001-X4 35 &VA1-FLS-00EAD03-E-M2-DWD-0608+/140.4
-X4 7
3 +X-B001 3 3 ==00EAD03=EH001-X10 35+ &VA1-FLS-00EAD03-E-M2-DWD-0608+/140.4
4 +X-B001 4 4 ==00EAD03=EH001-X10 35 &VA1-FLS-00EAD03-E-M2-DWD-0608+/140.5
D D
E E
F F
G G
270 +A008/272
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAC51=CL101+F04-X7 + F04
Appr. VUNG ANG ==00EAC51=CL101+F04-X7 Page 271
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=GS001+A008-X1
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
L1 1 +W000-X1 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/16.0
-Q001 1
L2 2 +W000-X1 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/16.1
C C
-Q001 3
L3 3 +W000-X1 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/16.1
PEN PE +W000-X1 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/16.1
D D
E E
F F
G G
+F04/271 273
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=GS001+A008-X1 + A008
Appr. VUNG ANG Page 272
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=GS001+A008-X4
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
1 &VA1-FLS-00EAD03-E-M2-DWD-0608/17.5
2 &VA1-FLS-00EAD03-E-M2-DWD-0608/17.5
3 -U002 &VA1-FLS-00EAD03-E-M2-DWD-0608/17.6
C C
4 -U002 &VA1-FLS-00EAD03-E-M2-DWD-0608/17.6
D D
E E
F F
G G
272 +A009/274
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=GS001+A008-X4 + A008
Appr. VUNG ANG Page 273
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4035
-4034
-4033
-4032
-4031
-4024
-4023
-4022
-4021
-4029
Strip
Cable name
Cable name
Li9Y11Y-HF ==00EAD03=AE002+A009-X4
Li9Y11Y-HF
Li9Y11Y-HF
Li9Y11Y-HF
Li9Y11Y-HF
H05VVC4V5-K
H05VVC4V5-K
H05VVC4V5-K
H05VVC4V5-K
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
1 +GY-Y001A 1 +F04-X4 1 1 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/31.3
2 +GY-Y001A 2 +F04-X4 2 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/31.4
1 +GY-Y001B 3 +F04-X4 3 3 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/31.5
C C
2 +GY-Y001B 4 +F04-X4 4 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/31.5
1 +F04-X4 5 5 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/32.0
2 +F04-X4 6 6 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/32.1
3 +F04-X4 7 7 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/32.1
4 +F04-X4 8 8 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/32.2
5 +F04-X4 9 9 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/32.2
10 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/32.4
6 +F04-X4 10 11 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/32.4
D D
7 +F04-X4 11 12 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/32.5
8 +F04-X4 12 13 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/32.5
14 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/32.6
15 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/32.7
9 +F04-X4 13 16 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/32.7
10 +F04-X4 14 17 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/32.8
11 +F04-X4 15 18 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/32.8
19 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/32.9
E E
20 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/33.0
12 +F04-X4 16 21 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/33.1
13 +F04-X4 17 22 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/33.1
23 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/33.2
1 +GY-Y002 x1 24 +F04-X4 18 1 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/34.1
2 +GY-Y002 x2 25 +F04-X4 19 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/34.1
1 +GY-Y003 x1 26 +F04-X4 20 3 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/34.2
2 +GY-Y003 x2 27 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/34.3
F F
1 +GY-Y004 x1 28 +F04-X4 21 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/34.4
2 +GY-Y004 x2 29 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/34.4
1 +GY-Y005 x1 30 +F04-X4 22 5 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/34.5
2 +GY-Y005 x2 31 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/34.6
1 +GY-Y006 x1 32 +F04-X4 23 6 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/34.7
2 +GY-Y006 x2 33 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/34.7
G G
+A008/273 275
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AE002+A009-X4 + A009
Appr. VUNG ANG Page 274
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4031
-4023
-4022
-4084
-4083
-4053
-4052
-4051
-4029
-4030
-4083
-4021
Strip
Cable name
Cable name
Li9Y11Y-HF ==00EAD03=AE002+A009-X4
H05VVC4V5-K
H05VVC4V5-K
H05VV5-F
H05VV5-F
Li9Y11Y-HF
Li9Y11Y-HF
Li9Y11Y-HF
H05VV5-F
H05VV5-F
H05VV5-F
H05VVC4V5-K
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
1 +GY-Y007 x1 34 +F04-X4 24 7 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/34.8
2 +GY-Y007 x2 35 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/34.9
1 +GY-Y008 x1 36 +F04-X4 25 1 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/35.1
C C
2 +GY-Y008 x2 37 +F04-X4 26 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/35.2
1 +GY-Y009 x1 38 +F04-X4 27 3 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/35.3
2 +GY-Y009 x2 39 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/35.3
40 +F04-X4 28 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/35.4
41 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/35.5
42 +F04-X4 29 5 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/35.6
43 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/35.6
44 +F04-X4 30 6 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/35.7
D D
45 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/35.8
46 +F04-X4 31 7 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/35.9
47 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/35.9
=CP121+F04-S004 2 48 =EH001+F04-X10 108+ 1 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/85.7
2 =EH001+F04-X10 108 49 =CP121+F04-S004 1 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/85.7
1 =EH001+F04-U1 3 50 =EH001+F04-X10 111+ &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/86.1
2 =EH001+F04-X10 111 51 =EH001+F04-U1 1 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/86.1
3 =EH001+F04-U1 4 52 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/86.2
E E
53 =EH001+F04-X10 112+ &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/86.2
4 =EH001+F04-X10 112 54 =EH001+F04-U1 2 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/86.2
55 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/86.2
56 =EH001+F04-X10 113+ &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/86.3
5 =EH001+F04-X10 113 57 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/86.3
58 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/86.3
GNYE +GY-Y001A PE +F04-X4 PE GNYE &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/31.3
-X4 PE
F F
GNYE +GY-Y001B PE -X4 PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/31.5
GNYE +GY-Y002 PE PE +F04-X4 PE GNYE &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/34.1
-X4 PE
G G
274 276
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AE002+A009-X4 + A009
Appr. VUNG ANG Page 275
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4053
-4052
-4051
-4035
-4034
-4033
-4032
-4030
Strip
Cable name
Cable name
==00EAD03=AE002+A009-X4
Li9Y11Y-HF
Li9Y11Y-HF
Li9Y11Y-HF
Li9Y11Y-HF
Li9Y11Y-HF
Li9Y11Y-HF
Li9Y11Y-HF
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
GNYE +GY-Y003 PE PE -X4 PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/34.3
-X4 PE
C C
GNYE GNYE +GY-Y004 PE PE -X4 PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/34.4
-X4 PE
GNYE +GY-Y005 PE PE -X4 PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/34.6
-X4 PE
GNYE +GY-Y006 PE PE -X4 PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/34.7
-X4 PE
GNYE +GY-Y007 PE PE -X4 PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/34.9
GNYE +GY-Y008 PE PE +F04-X4 PE GNYE &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/35.2
D D
-X4 PE
GNYE +GY-Y009 PE PE -X4 PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/35.3
-X4 PE
PE -X4 PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/35.5
-X4 PE
PE -X4 PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/35.6
-X4 PE
PE -X4 PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/35.7
E E
-X4 PE
PE -X4 PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/35.9
F F
G G
275 +A010/277
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AE002+A009-X4 + A009
Appr. VUNG ANG ==00EAD03=AE002+A009-X4 Page 276
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-1008
-1007
-1006
-1005
-1004
Strip
Cable name
Cable name
==00EAD03=AE001+A010-X1
H07 RN-F
H07 RN-F
H07 RN-F
H07 RN-F
H07 RN-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
-F002 1 1 +F03-X1 4 BN &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/22.0
-F002 3 2 +F03-X1 5 BK &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/22.1
-F002 5 3 +F03-X1 6 GY &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/22.1
C C
BN +X-M001 U1 4 -F002 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/23.2
BK +X-M001 V1 5 -F002 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/23.2
GY +X-M001 W1 6 -F002 6 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/23.3
BN +X-M002 U1 7 -F003 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/23.7
BK +X-M002 V1 8 -F003 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/23.7
GY +X-M002 W1 9 -F003 6 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/23.7
BN +X-M003 U1 10 -F004 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/24.2
BK +X-M003 V1 11 -F004 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/24.2
D D
GY +X-M003 W1 12 -F004 6 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/24.3
BN +X-M004 U1 13 -F005 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/24.7
BK +X-M004 V1 14 -F005 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/24.7
GY +X-M004 W1 15 -F005 6 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/24.7
-X1 PE PE +F03-X1 PE GNYE &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/22.1
GNYE +X-M001 PE -X1 PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/23.3
-X1 PE
GNYE +X-M002 PE -X1 PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/23.7
E E
-X1 PE
GNYE +X-M003 PE -X1 PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/24.3
-X1 PE
GNYE +X-M004 PE -X1 PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/24.7
F F
G G
+A009/276 278
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AE001+A010-X1 + A010
Appr. VUNG ANG Page 277
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4006
-4005
-4004
-4003
-4002
Strip
Cable name
Cable name
==00EAD03=AE001+A010-X5
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
1 +X-M001 1 +F03-X5 1 1 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/23.1
2 +X-M001 2 +F03-X5 2 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/23.2
1 +X-M002 3 +F03-X5 3 3 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/23.6
C C
2 +X-M002 4 +F03-X5 4 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/23.6
1 +X-M003 5 +F03-X5 5 5 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/24.1
2 +X-M003 6 +F03-X5 6 6 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/24.2
1 +X-M004 7 +F03-X5 7 7 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/24.6
2 +X-M004 8 +F03-X5 8 8 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/24.6
D D
E E
F F
G G
277 279
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AE001+A010-X5 + A010
Appr. VUNG ANG Page 278
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4011
-4010
-4009
-4008
-4007
Strip
Cable name
Cable name
==00EAD03=AE001+A010-X6
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
1 +X-M001 1 +F03-X6 1 1 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/25.1
2 +X-M001 2 +F03-X6 2 2 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/25.1
3 +X-M001 3 +F03-X6 3 3 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/25.1
C C
4 +X-M001 4 +F03-X6 4 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/25.2
1 +X-M002 5 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/25.3
2 +X-M002 6 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/25.4
3 +X-M002 7 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/25.4
4 +X-M002 8 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/25.4
1 +X-M003 9 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/25.6
2 +X-M003 10 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/25.6
3 +X-M003 11 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/25.6
D D
4 +X-M003 12 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/25.6
1 +X-M004 13 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/25.8
2 +X-M004 14 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/25.8
3 +X-M004 15 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/25.8
4 +X-M004 16 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/25.9
GNYE +X-M001 PE PE +F03-X6 PE GNYE &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/25.2
-X6 PE
GNYE +X-M002 PE PE -X6 PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/25.4
E E
-X6 PE
GNYE +X-M003 PE PE -X6 PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/25.6
-X6 PE
GNYE +X-M004 PE PE -X6 PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/25.9
F F
G G
278 280
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AE001+A010-X6 + A010
Appr. VUNG ANG Page 279
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4075
-4074
-4073
-4072
-4071
Strip
Cable name
Cable name
==00EAD03=AE001+A010-X10
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
2 =CG111+X-S001 1 1 =EH001+F04-X10 45 2 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/79.5
1 =CG111+X-S001 4 2 =EH001+F04-X10 45+ 1 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/79.5
1 =CG111+X-S002 1 3 =EH001+F04-X10 46 3 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/79.6
C C
2 =CG111+X-S002 4 4 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/79.6
1 =CG111+X-S003 1 5 =EH001+F04-X10 47 4 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/79.7
2 =CG111+X-S003 4 6 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/79.7
1 =CG111+X-S004 1 7 =EH001+F04-X10 48 5 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/79.7
2 =CG111+X-S004 4 8 &VA1-FLS-00EAD03-E-M2-DWD-0608=EH001+F04/79.8
D D
E E
F F
G G
279 281
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AE001+A010-X10 + A010
Appr. VUNG ANG Page 280
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
Strip
Cable name
Cable name
==00EAD03=EH001+A010-X10
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
+F04-X10 72+ 1 =AE001-F002 13 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/82.2
2 =AE001-F003 13 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/82.3
3 =AE001-F004 13 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/82.4
C C
4 =AE001-F005 13 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/82.5
=AE001-F002 14 5 +F04-X10 72 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/82.2
=AE001-F003 14 6 +F04-X10 73 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/82.3
=AE001-F004 14 7 +F04-X10 74 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/82.4
=AE001-F005 14 8 +F04-X10 75 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/82.5
D D
E E
F F
G G
280 +LC01/282
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+A010-X10 + A010
Appr. VUNG ANG Page 281
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4013
Strip
Cable name
Cable name
==00EAD03=AE001+LC01-X3
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
1 +F01-2-X3 3 1 +F01-S001 13 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/26.5
2 +F01-2-X3 4 2 +F01-S001 14 &VA1-FLS-00EAD03-E-M2-DWD-0608+F01/26.5
C C
D D
E E
F F
G G
+A010/281 283
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AE001+LC01-X3 + LC01
Appr. VUNG ANG Page 282
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-1016
-1015
Strip
Cable name
Cable name
==00EAD03=GU002+LC01-X1
H07 RN-F
H07 RN-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
-T001 1U 1 +F01-6-X1 1 BN &VA1-FLS-00EAD03-E-M2-DWD-0608+/47.2
-T001 1V 2 +F01-6-X1 2 BK &VA1-FLS-00EAD03-E-M2-DWD-0608+/47.2
-T001 1W 3 +F01-6-X1 3 GY &VA1-FLS-00EAD03-E-M2-DWD-0608+/47.3
C C
BN +F01-6-X1 4 4 -T001 2W &VA1-FLS-00EAD03-E-M2-DWD-0608+/47.2
BK +F01-6-X1 5 5 -T001 2U &VA1-FLS-00EAD03-E-M2-DWD-0608+/47.2
GY +F01-6-X1 6 6 -T001 2V &VA1-FLS-00EAD03-E-M2-DWD-0608+/47.3
BL +F01-6-X1 7 7 -T001 2N &VA1-FLS-00EAD03-E-M2-DWD-0608+/47.3
-T001 PE PE +F01-6-X1 PE GNYE &VA1-FLS-00EAD03-E-M2-DWD-0608+/47.3
GNYE +F01-6-X1 PE PE &VA1-FLS-00EAD03-E-M2-DWD-0608+/47.3
D D
E E
F F
G G
282 284
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=GU002+LC01-X1 + LC01
Appr. VUNG ANG Page 283
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-1052
Strip
Cable name
Cable name
==00EAD03=AH003+LC01-X2
H07 RN-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
-S001 1 1 +F02-7-X2 5 BN &VA1-FLS-00EAD03-E-M2-DWD-0608+/59.4
-S001 5 2 +F02-7-X2 6 BU &VA1-FLS-00EAD03-E-M2-DWD-0608+/59.5
-M01 1 3 -S001 3 &VA1-FLS-00EAD03-E-M2-DWD-0608+/59.4
C C
-M01 2 4 -S001 5 &VA1-FLS-00EAD03-E-M2-DWD-0608+/59.5
-M01 PE PE +F02-7-X2 PE GNYE &VA1-FLS-00EAD03-E-M2-DWD-0608+/59.5
D D
E E
F F
G G
283 285
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=AH003+LC01-X2 + LC01
Appr. VUNG ANG Page 284
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4097
-4065
-4041
-4013
Strip
Cable name
Cable name
==00EAD03=EH001+LC01-X4
H05VV5-F
H05VV5-F
H05VV5-F
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
1 +F02-7-X4 1 1 -A20 L+ &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/62.7
2 +F02-7-X4 5 2 -A20 M &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/62.7
4 +F02-7-X4 9 3 -A20 A &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/62.8
C C
3 +F02-7-X4 8 4 -A20 B &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/62.8
+F04-X10 53+ 5 =AE001+F01-S001 23 3 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/80.3
+F04-X10 53 6 =AE001+F01-S001 24 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/80.3
2 +F04-X10 187+ 7 =CH122+X-S007 13 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/93.7
1 +F04-X10 187 8 =CH122+X-S007 14 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/93.7
2 +F04-X10 216+ 9 -S001 13 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/96.6
1 +F04-X10 216 10 -S001 14 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/96.6
4 +F04-X10 217+ 11 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/96.7
D D
3 +F04-X10 217 12 &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/96.7
GNYE +F02-7-X4 PE PE -A20 PE &VA1-FLS-00EAD03-E-M2-DWD-0608+F04/62.7
E E
F F
G G
284 286
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=EH001+LC01-X4 + LC01
Appr. VUNG ANG Page 285
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
-4065
Strip
Cable name
Cable name
==00EAD03=CH102+LC01-X3
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
=CH122+X-S007 11 1 +F03-X3 32 3 &VA1-FLS-00EAD03-E-M2-DWD-0608+/109.4
=CH122+X-S007 12 2 +F03-X3 33 4 &VA1-FLS-00EAD03-E-M2-DWD-0608+/109.5
=CH122+X-S007 21 3 +F03-X3 34 5 &VA1-FLS-00EAD03-E-M2-DWD-0608+/109.5
C C
=CH122+X-S007 22 4 +F03-X3 35 6 &VA1-FLS-00EAD03-E-M2-DWD-0608+/109.5
D D
E E
F F
G G
285 +X/287
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAD03=CH102+LC01-X3 + LC01
Appr. VUNG ANG Page 286
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
==00EAD03-4058
Strip
Cable name
Cable name
==00EAC03=CG104+X-X10
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
2 ==00EAD03=EH001+F04-X10 28+ 1 -S001 BN &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/77.7
1 ==00EAD03=EH001+F04-X10 28 2 -S001 BU &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/77.7
C C
D D
E E
F F
G G
+LC01/286 288
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAC03=CG104+X-X10 +X
Appr. VUNG ANG Page 287
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
==00EAD03-4049
==00EAD03-4050
Strip
Cable name
Cable name
==00EAC03=CG101+X-S001
H05VV5-F
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
1 ==00EAD03=EH001+F04-X10 24 1 =CG102-S001 12 1 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/77.4
3 ==00EAD03=EH001+F04-X10 25 2 =CG102-S001 32 2 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/77.5
C C
D D
E E
F F
G G
287 289
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAC03=CG101+X-S001 +X
Appr. VUNG ANG Page 288
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
==00EAD03-4068
==00EAD03-4069
Strip
Cable name
Cable name
==00EAC03=CG105+X-S001
H05VV5-F
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
1 ==00EAD03=EH001+F04-X10 33 1 ==00EAC51=CG106-S001 12 1 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/78.3
3 ==00EAD03=EH001+F04-X10 34 2 ==00EAC51=CG106-S001 32 2 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/78.4
C C
D D
E E
F F
G G
288 290
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAC03=CG105+X-S001 +X
Appr. VUNG ANG Page 289
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
==00EAD03-4056
Strip
Cable name
Cable name
==00EAC03=CS101+X-X10
H05VV5-F
Connection
Connection
B B
cable type
cable type
terminal
jumper
point
point
Target designation Target designation Page / column
-S001 1 1 ==00EAD03=EH001+F04-X10 26+ 2 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/77.6
-S001 2 2 ==00EAD03=EH001+F04-X10 26- 3 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/77.6
-S001 3 3 ==00EAD03=EH001+F04-X10 26 1 &VA1-FLS-00EAD03-E-M2-DWD-0608==00EAD03=EH001+F04/77.6
C C
D D
E E
F F
G G
289 ==CABLE+/291
Date 13.10.2011 2.2040 TERMINAL
Terminal diagram Stacker
Ed. by cw-de ==00EAC03=CS101+X-X10 +X
Appr. VUNG ANG Page 290
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
==TERMINAL+X/290 292
Date 13.10.2011 2.2040 CABLE
Cable overview : ==00EAD03-1000 - Stacker
Ed. by cw-de ==00EAD03-1039 +
Appr. VUNG ANG Page 291
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
291 293
Date 13.10.2011 2.2040 CABLE
Cable overview : ==00EAD03-1040 - Stacker
Ed. by cw-de ==00EAD03-4026 +
Appr. VUNG ANG Page 292
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
292 294
Date 13.10.2011 2.2040 CABLE
Cable overview : ==00EAD03-4027 - Stacker
Ed. by cw-de ==00EAD03-4065 +
Appr. VUNG ANG Page 293
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
293 295
Date 13.10.2011 2.2040 CABLE
Cable overview : ==00EAD03-4066 - Stacker
Ed. by cw-de ==00EAD03-4103 +
Appr. VUNG ANG Page 294
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295
0 1 2 3 4 5 6 7 8 9
C C
D D
E E
F F
G G
294
Date 13.10.2011 2.2040 CABLE
Cable overview : ==00EAD03-4104 - Stacker
Ed. by cw-de ==00EAC51-4069 +
Appr. VUNG ANG Page 295
2.2040 VA1-FLS-00EAD03-E-M2-DWD-0608
Revision Date Name Total 295