State the starting operation procedure of main engine and propulsion plant
Start pre-lubrication of the engine well before starting the marine engine. For the
main engine it should be started before 1 hour and for auxiliary 4-stroke engines
at least 15 minutes in advance.
After starting the lubrication pump, check lube oil levels and all other running
pump parameters such as cooling water pressure, fuel oil temp and pressure,
control and starting air pressure to ensure that all are in the accepted range.
All the indicator cocks of the marine engine must be opened up for blow through
of combustion chamber prior starting in order to avoid hydraulic damage because
of water leakage.
Rotate the crankshaft of the marine engine by means of turning gear so that all
the parts are thoroughly lubricated before starting.
Ensure that the turning gear is properly disengaged by checking it locally even
when the remote signal is showing “disengaged” sign. Some auxiliary engines
are provided with tommy bar for rotation, ensure that it is removed from the
flywheel before the engine is started.
The jacket cooling water temperature of the engine should be maintained at least
60 deg C for the main engine and 40 deg C for the auxiliary engine (it may vary
depending upon the KW rating of the engine).
The incoming ship generator should be run at no load for at least 5 mins to allow
warming up of the system.
possible due to the auto load automation provided for sharing the equal load (if
same rated capacity).
lves,
open the spring air first and then start the hydraulic oil to the exhaust valve. This
will avoid excessive opening of valves.
3. What kinds of condition do not allow the main engine to start?
Pre-lubrication of engine had not be done well before starting the marine engine.
After starting the lubrication pump, all important parameters such as checking lube oil
levels and all other running pump had not be ensure in accepted range.
Close all the indicator cocks of the marine engine which it blows through of combustion
chamber prior starting that may causes hydraulic damage because of water leakage.
Pre-lubrication of engine had not be done well before starting the marine engine.
After starting the lubrication pump, all important parameters such as checking lube oil
levels and all other running pump had not be ensure in accepted range.
Close all the indicator cocks of the marine engine which it blows through of combustion
chamber prior starting that may causes hydraulic damage because of water leakage.
6. State the starting operation procedure of Fresh Water Generator.
Open the Engine Room Release Cabinet (A1) marked engine room on fire. The C02
alarm will
now sound in the protected space.
Be sure that all personnel area evacuated from the protected space.
Before operating the system, close all openings to the protected space, stop engines,
close quick-closing valves for fuel, stop fuel pumps and purifiers, shut down the
ventilation.
The Main Valve (E1) will be open immediately, a time delay until will delay the operation
of the
C02 cylinder top valves (D). After a pre-set time (60-90 sec). The C02 gas will be
discharged into
the engine room.
In case of failure in the operation of the system from the release cabinet, the system can
be manually operated according to the following procedure,
Open the main valve (E1) for the engine room on fire.
Be sure that all personnel are evacuated from the protected space.
The well known fixed firefighting systems mounted on most ships are the CO2flooding
system or the central bank CO2 system. Carbon dioxide (CO2) is released into a
protected space in bulk quantities such as the engine room and cargo hold