ISOBUS Quick Reference

Installation Guide

Liquid Fertilizer
Anhydrous Ammonia
Sprayer
Spreader
Slurry

1
2
Table of Contents
1 ISOBUS System Overview...............................................................3
1.1 Anhydrous Ammonia / Liquid Fertilizer...............................................3
1.2 Sprayer ............................................................................................3
1.3 Spreader............................................................................................4
1.4 Slurry ............................................................................................4
2 Liquid Fertilizer / NH3 / Sprayer Installation..................................5
2.1 Cabling Diagram................................................................................5
2.2 Field-IQ/AccuGuide/IntelliRate Cabling..............................................6
2.3 Field-IQ/AccuGuide/IntelliRate Cabling Description...........................7
2.4 Raven 4X0 Series Cabling ................................................................8
2.5 Raven 4X0 Series Cabling Description..............................................9
2.6 Raven 4XX0 Series Cabling ............................................................10
2.7 Raven 4XX0 Series Cabling Description.......................................... 11
2.8 Physical Installation.......................................................................... 11
2.9 Spartan Direct Injection System.......................................................15
3 Spreader Installation......................................................................19
3.1 Cabling Diagram..............................................................................19
3.2 Field-IQ/AccuGuide/IntelliRate Cabling............................................20
3.3 Field-IQ/AccuGuide/IntelliRate Cabling Description.........................21
3.4 Raven 660 Series Cabling ..............................................................22
3.5 Raven 660 Series Cabling Description............................................23
3.6 Physical Installation..........................................................................24
4 Slurry Installation...........................................................................28
4.1 Slurry Cabling Diagram....................................................................28
4.2 Slurry Cabling Diagram Description.................................................29
4.3 Physical Installation..........................................................................30
5 ISOBUS Resources........................................................................33
5.1 ISOBUS Demo Stand.......................................................................33
5.2 ISOBUS Online Resources..............................................................33

3
4
1 ISOBUS System Overview
1.1 Anhydrous Ammonia/Liquid Fertilizer
• ISOBUS compatible display
• ISOBUS ready tractor

12v 4

ISOBUS Harness ISOBUS Liquid ECU Harness


q e
ISOBUS ECU Component cabling
w r
1.2 Sprayer
• ISOBUS compatible display
• ISOBUS ready tractor

7
4

12v

ISOBUS Harness ISOBUS Liquid ECU Harness


q e
ISOBUS ECU Component cabling
w r

5
1.3 Spreader
• ISOBUS compatible display
• ISOBUS ready tractor

hopper
cover

7
bin
level
1 2
bin
level belt
speed
HYD
12v 3 belt
speed

spinner
speed

ISOBUS Harness ISOBUS Liquid ECU Harness


q e
ISOBUS ECU
w
1.4 Slurry
• ISOBUS compatible display
• ISOBUS ready tractor 4

2
1

12v

ISOBUS Harness ISOBUS Liquid ECU Harness


q e
ISOBUS ECU Component cabling
w r

6
2 Liquid Fertilizer/NH3/Sprayer Installation
2.1 Cabling Diagram

7
2.2 Field-IQ/AccuControl/IntelliRate Cabling

8
2.3 Field-IQ/AccuControl/IntelliRate Cabling Description
Item Description Part Number Part Number Description

1 ISOBUS Harness ME0502001-03 Implement with Master Switch - 3ft.


ME0502001-08 Implement with Master Switch - 8ft.
ME0502001-13 Implement with Master Switch - 13ft.
ME0502001-21 Implement with Master Switch - 21ft.
ME0502001-28 Implement with Master Switch - 28ft.
ME0502001-36 Implement with Master Switch - 36ft.
ME0502001-43 Implement with Master Switch - 43ft.
2 Liquid Fertilizer ECU ME30481010

3 Liquid Fertilizer ECU Complete Harness ME0512001

4 Master/Implement Switch

5 Radar input connection

6 Tank control connection

7 Power connection

8 Section connection

9 Rate connection

10 Aux. connection

11 Section Valve Adapter Cable ZTN80587 Field-IQ 5 boom adapter


ZTN80961 Field-IQ 10 boom adapter
ZTN77541 Raven 7 boom adapter
ZTN78225 Raven 10 boom adapter
12 Field-IQ/AccuCtrl/IntelliRate Adapter Harness ME0502025

13 Aux. I/O

14 Spinner control (not applicable for liquid fertilizer)

15 Regulation connection ZTN80534 Field-IQ to Raven Fast Valve


ZTN80586 Field-IQ to Raven control valve adapter
ZTN80531 Field-IQ to Dickey-john control valve
ZTN80960 Dickey-John PWM control valve adapter
ZTN81970 Raven Standard valve 063-0172-977 (round 4-pin lock ring connector)
ZTN81554 Raven Fast valve (flat 2-pin connector)
16 Flow connection

17 Flow Meter Cable

18 Flow Control Adapter Cable ZTN80584 Field-IQ to Raven flowmeter adapter


ZTN80539 Field-IQ to Dickey-john encoder/flowmeter
19

9
2.4 Raven 4X0 Series Cabling

10
2.5 Raven 4X0 Series Cabling Description
Item Description Part Number Part Number Description
1 ISOBUS Harness ME0502001-03 Implement with Master Switch - 3ft.
ME0502001-08 Implement with Master Switch - 8ft.
ME0502001-13 Implement with Master Switch - 13ft.
ME0502001-21 Implement with Master Switch - 21ft.
ME0502001-28 Implement with Master Switch - 28ft.
ME0502001-36 Implement with Master Switch - 36ft.
ME0502001-43 Implement with Master Switch - 43ft.
2 Liquid ECU ME30481010
3 Liquid ECU to 4X0 Harness ME0512008
4 Master/Implement Switch
5 Pressure connection
6 Pressure Sensor * Denotes Raven part # 422-0000-090*
7 Raven Flow Cable 115-0159-858* Flow Cable 6 ft. 3 Boom
* Denotes Raven part # 115-0171-836* Flow Cable 12 ft. 3 Boom
8 Control Valve
9 Master On/Off Valve
10 Boom Valves
11 Flox Extension Cable 115-0159-016* Flow Extension Cable 6 ft.
115-0159-017* Flow Extension Cable 12 ft.
115-0159-019* Flow Extension Cable 24 ft.
* Denotes Raven part #
115-0171-544* Flow Extension Cable 36.5 ft.
12 Flow Meter

11
2.6 Raven 4XX0 Series Cabling

12
2.7 Raven 4XX0 Series Cabling Description
Item Description Part Number Part Number Description
1 ISOBUS Harness ME0502001-03 Implement with Master Switch - 3 ft.
ME0502001-08 Implement with Master Switch - 8 ft.
ME0502001-13 Implement with Master Switch - 13 ft.
ME0502001-21 Implement with Master Switch - 21 ft.
ME0502001-28 Implement with Master Switch - 28 ft.
ME0502001-36 Implement with Master Switch - 36 ft.
ME0502001-43 Implement with Master Switch - 43 ft.
2 Liquid ECU ME30481010
3 Liquid ECU to 4XX0 Harness ME0512009
4 Master/Implement Switch
5 Raven Flow Cable 115-0171-313* Flow Cable 12 ft. 10 Boom
115-0171-314* Flow Cable 24 ft. 10 Boom
115-0171-315* Flow Cable 12 ft. 5 Boom
* Denotes Raven part # 115-0171-316* Flow Cable 24 ft. 5 Boom
6 Control Valve
7 Boom Valves 063-0171-926* Boom Valve Cable - 1 section
063-0171-928* Boom Valve Cable - 3 section
* Denotes Raven part # 063-0171-039* Boom Valve Cable - 5 section
8 Pressure Sensor Cable 115-0171-235* Pressure Sensor Cable - 6 ft.
115-0171-151* Pressure Sensor Cable - 12 ft.
115-0171-224* Pressure Sensor Cable - 37 ft.
* Denotes Raven part # 115-0171-296* Pressure Sensor Cable - 44 ft.
9 Optional Pressure Sensor * Denotes Raven part # 422-000-090*
10 Flow Extension Cable 115-0159-016* Flow Extension Cable - 6 ft.
115-0159-017* Flow Extension Cable - 12 ft.
115-0159-019* Flow Extension Cable - 24 ft.
* Denotes Raven part # 115-0159-544* Flow Extension Cable - 36.5 ft.
11 Flow Meter
12 Flow Control Adapter Cable ZTN80584 Field-IQ to Raven flowmeter adapter
ZTN80539 Field-IQ to DICKEY-john encoder/flowmeter

13
2.8 Physical Installation
1. Route the ISO Implement Cable from the ECU to the implement hitch
point. This cable will mate with the Tractor ISOBUS connector. (factory
equipped)

2. Locate a stable and flat area of the implement approximately 8 by 16


inches. Using four 1/4“ x 3/4“ length (or another length required) bolts
and nylon locking nuts, bolt the ECU to the toolbar.

14
3. Plugin the ISO Implement Cable harness to the ISOBUS connection
on the ECU. If the harness is connected incorrectly, the system will not
power up.

4. Connect the Liquid ECU harness to the 42-pin connector on the ECU.

15
5. Connect the adapter harness (Field-IQ/AccuControl/IntelliRate, Raven
4X0, Raven 4XX0) to the Liquid ECU harness. Next, connect your
adapter harness to the existing components on your implement.

16
2.9 Spartan Direct Injection System
Mueller Electronics recommends the Spartan Direct Injection System for
NH3. The parts below are designed and tested to work with the Mueller NH3
system and should be ordered directly from SureFire Ag Systems.

Part Number: Description:


508-04-110100 Spartan Injection Pump Kit Model 110 (2-10 oz/min)
508-04-120100 Spartan Injection Pump Kit Model 120 (3-20 oz/min)
508-04-130100 Spartan Injection Pump Kit Model 130 (5-40 oz/min)
508-04-140100 Spartan Injection Pump Kit Model 140 (10-80 oz/min)

All four pump models are identical as viewed from the outside. Each pump
model has a different displacement to achieve the desired flow range. The
flow switch on the 110 and 120 models is a special low flow switch (which
also appears identical from the outside).

Specifications for all pump models:


• Pressure: Max Operating 80 PSI
- Care should be taken not to restrict pump outlet as it will develop up to 290 psi which
may cause failure of plumbing fittings.
• Voltage: 12 VDC vehicle electrical system
• Current: Max 16.3 amps
• Pump speed: 0 – 120 rpm
• Pump Case Oil: Mobil Super 5W30 Conventional Motor Oil

Pump Kit Components:


• Spartan Injection Pump
- 3/8” QC Inlet
- 3/8” QC Outlet or ¼” QC Outlet
• 20’ Fused Power Cable w/ 480MP Connector– 6 AWG
• Magnetic Mount Liquid Filled Pressure Gauge w/ Tee Connection
• 10 PSI Pressure Maintaining Check Valve on Pump Outlet
• 50 mesh strainer recommended for all installations
- Strainer IS NOT included with pump kit
- Strainer IS included on 20, 55 & 110 Gallon Spartan Tanks

17
Each Spartan pump includes a bag with the items shown to be installed
according to this diagram.

Mixing chamber and one way


check valve sold separately

Tank Kits:

Part Number: Description:


508-02-100100 20 Gallon Spartan Tank Kit
508-02-100200 55 Gallon Spartan Tank Kit
508-02-100300 110 Gallon Spartan Tank Kit

All tank kits include:


• Mounting location for Spartan pump on the tank bracket
• 3/8” Hose for connection to pump
• Strainer
The 55 and 100 Gallon Tank kits also include a black tank base for holding
rinse water or antifreeze. This makes it extremely easy to flush the Spar-
tan pump daily after use to reduce issues caused by chemical sitting in the
pump.

18
Mixing Chambers:

Part Number: Description:


716-333-0011-102 N-Serve Check Valve
Part Number TBD NEW Mixing Chamber with built in injection port

The 55 and 100 Gallon Tank kits also include a black tank base for holding
rinse water or antifreeze. This makes it extremely easy to flush the Spar-
tan pump daily after use to reduce issues caused by chemical sitting in the
pump.

Recommendations for N-Serve:


• Spartan is a great pump for injecting N-Serve NH3 Stabilizer.
• Given customer’s implement width, rates and speed SureFire will help
choose the right pump model to fit their needs.
• For many N-Serve cases, the Spartan 130 at 5-40 oz/min is the best fit.

Width Speed Rate Spartan Flow


30 feet 4 MPH 1 qt / acre 7.8 oz/min
40 feet 4 MPH 1 qt / acre 10.3 oz/min
60 feet 10 MPH 1 qt / acre 38.8 oz/min

For any 30-60 ft wide applicator running 4-10 MPH speeds and applying
the recommended rate of 1 quart N-Serve / acre, the Spartan 130 model is
recommended.

19
Spartan Injection & Raven HP Cabling Guide:

Part Number: Description:


ME0512010 Harness, Boost Pump Adapter
ME30322547 Harness, In-cab CPC Connector

20
3 Spreader Installation
ME SPREADER
3.1 Cabling Diagram GOOD
Foot Pedal Extension, 15ft.
Foot Pedal
with 12 ft. Cable 5
CNHi Harness
#77611-01
#75528-xx

ISOBUS Harness 1a OR 1b Trimble ISO


Implement with to ECU Harness, 3 ft.
Master Switch

Spreader
ECU
Master / implement
switch

SPREADER SYSTEM
Item Description

3
1a ISOBUS Harness
Spreader ECU 1b Trimble ISO to ECU Harness
Harness
2 Spreader ECU
3 Spreader Complete Harness
4a Raven 660 22-pin Adapter
4b FIQ/AccuCrtl/IntelliRate Adapter
Wheel
Speed 5 Foot Pedal w/ 12 ft. cable

4a 4b

Aux. I/O spinner


spinner control
control

rate encoder
control
Raven 660 Field IQ/ AccuCtrl/
22 pin Adapter IntelliRate
Adapter

21
3.2 Field-IQ/AccuControl/IntelliRate Cabling

9 10

13
11 12

14 15

22
3.3 Field-IQ/AccuControl/IntelliRate Cabling Description
Field-IQ / AccuControl / IntelliRate Spreader Harness
Item Description Part Number Part Number Description
1 ISOBUS Harness ME0502001-03 Implement with Master Switch - 3ft.
ME0502001-08 Implement with Master Switch - 8ft.
ME0502001-13 Implement with Master Switch - 13ft.
ME0502001-21 Implement with Master Switch - 21ft.
ME0502001-28 Implement with Master Switch - 28ft.
ME0502001-36 Implement with Master Switch - 36ft.
ME0502001-43 Implement with Master Switch - 43ft.
2 Spreader ECU ME30481050
3 Spreader Complete Harness ME0511000
4 Master/Implement Switch
5 Radar Input Connection
6 Rate Connection
7 Rate Control Extension
8 Field-IQ/AccuCtrl/IntelliRate Adapter ME0502025
Harness
9 Aux Connection
10 Spinner Control Connection
11 Control Connection
12 Feedback Connection
13 Spreader gate height & spinner ZTN80507
speed Adapter Cable
14 Flow Control Adapter Cable:
• Field-IQ to Raven Fast Valve ZTN80534
• Field-IQ to Raven Control Valve ZTN80586
adapter
• Dickey-john Control Valve adapter ZTN80960
(2 pin)
15 Field-IQ to Dickey-John encoder/ ZTN80539
flowmeter

23
3.4 Raven 660 Series Cabling

10 14

11 14
12 13

24
3.5 Raven 660 Series Cabling Description
Raven 660 Spreader Harness
Item Description Part Number Part Number Description
1 ISOBUS Harness ME0502001-03 Implement with Master Switch - 3ft.
ME0502001-08 Implement with Master Switch - 8ft.
ME0502001-13 Implement with Master Switch - 13ft.
ME0502001-21 Implement with Master Switch - 21ft.
ME0502001-28 Implement with Master Switch - 28ft.
ME0502001-36 Implement with Master Switch - 36ft.
ME0502001-43 Implement with Master Switch - 43ft.
2 Spreader ECU ME30481050
3 Spreader Complete Harness ME0511000
4 Master/Implement Switch
5 Radar Input Connection
6 Rate Connection
7 Rate Control Extension
8 Raven 660 Adapter Harness ME0502014
9 Spinner Control Connection
10 Raven Flow Cable *Denotes Raven part # 115-0159-787*
11 Encoder
12 Flow Extension Cable 115-0159-016* Flow Extension Cable - 6ft.
115-0159-017* Flow Extension Cable - 12ft.
115-0159-019* Flow Extension Cable - 24ft.
*Denotes Raven part # 115-0171-544* Flow Extension Cable - 36.5ft.
13 Clutches and Sensors
14 Hydraulic Valve Control

25
3.6 Physical Installation
1. Route the ISO Implement Cable from the ECU to the implement hitch
point. This cable will mate with the Tractor ISOBUS connector. (factory
equipped)

2. Locate a stable and flat area of the implement approximately 8 by 16


inches. Using four 1/4“ x 3/4“ length (or another length required) bolts
and nylon locking nuts, bolt the ECU to the spreader.

26
3. Plugin the ISO Implement Cable harness to the ISOBUS connection
on the ECU. If the harness is connected incorrectly, the system will not
power up.

4. Connect the Liquid ECU harness to the 42-pin connector on the ECU.

27
5. Connect the Rate Extension harness to the Spreader ECU harness.

6. Plug the Rate Extension harness into your (Field-IQ/AccuControl/


IntelliRate or Raven 660). Next, connect your adapter harness to the
existing components on the spreader.

28
29
4 Slurry Installation
4.1 Slurry Cabling Diagram

30
4.2 Slurry Cabling Diagram Description
ISOBUS Slurry System
Item Description Part Number Part Number Description
1a ISOBUS Harness ME0502001-03 Implement with Master Switch - 3ft.
ME0502001-08 Implement with Master Switch - 8ft.
ME0502001-13 Implement with Master Switch - 13ft.
ME0502001-21 Implement with Master Switch - 21ft.
ME0502001-28 Implement with Master Switch - 28ft.
ME0502001-36 Implement with Master Switch - 36ft.
ME0502001-43 Implement with Master Switch - 43ft.
1b Trimble ISO to ECU Harness ME0502036
2 Slurry ECU ME30481100
3 Slurry to Raven Adapter Harness ME0513000
4 Foot Pedal with 12 ft. Cable ME0520000 Foot Pedal with 12 ft. Cable
ME0520001 Foot Pedal Extension - 15 ft.
ME3032259206 Downloadbox

31
4.3 Physical Installation
1. Route the ISO Implement Cable from the ECU to the implement hitch
point. This cable will mate with the Tractor ISOBUS connector. (factory
equipped)

2. Locate a stable and flat area of the implement approximately 8 by 16


inches. Using four 1/4“ x 3/4“ length (or another length required) bolts
and nylon locking nuts, bolt the ECU to the slurry tank.

32
3. Plugin the ISO Implement Cable harness to the ISOBUS connection
on the ECU. Make sure you don’t connect the harness to the OUT side
of the ECU. If the harness is connected incorrectly, the system will not
power up.

4. Connect the Slurry Adapter harness to the 42-pin connector on the


ECU.

33
5. Connect the adapter harness into the Raven 660 harness.

34
5 ISOBUS Resources
5.1 ISOBUS Demo Stand
This is a great tool for ISOBUS sales demo, ECU configuration, and software
updating. Order the kit from the part numbers below.

ME0901001
Part Number: Description:
ME0901001 ME_VB Demo Board
ME0502015* Harness, Pro700 Case IH Display Adapter with CPC & Asst Steer-
ing Breakout
ME0502001-03* Implement with Master Switch – 3 ft. Used to connect ECU to
Demo Stand
*Not shown in picture above
Limited Stock - delivery times maybe 4 to 6 weeks

5.2 ISOBUS Online Resources


CNH dealers are invited to have access to a private Google Drive with
resources for ISOBUS control systems. The drive contains firmware, docu-
mentation for setup and installation, ordering guides, service bulletins, and
training videos. For access, send an email message to shawn.honken@
mueller-electronics.com.

35