Professional Documents
Culture Documents
Series 4300 Vertical In-Line: Submittal
Series 4300 Vertical In-Line: Submittal
527L
DATE: Sept. 8, 2010
SUPERSEDES: 43.527L
DATE: May 17, 2010
OPTIONAL EQUIPMENT P R
S D
3/8" OD XY
SEE FILE NO. 43.50 FOR ENVIRONMENTAL ACCESSORIES Flush Line
C
E
with Vent
MAXIMUM PUMP OPERATING CONDITIONS**
ANSI 125 ANSI 250
12 bar at 60°C (175 psi at 140°F) 26 bar at 38°C (375 psi at 100°F)
7 bar at 149°C (100 psi at 300°F) 19 bar at 149°C (275 psi at 300°F)
T SD
SEE FILE NO. 43.50 FOR MAXIMUM SEAL OPERATING CONDITIONS
COUPLING GUARD (NOT SHOWN) IS SUPPLIED. PUMP DIMENSIONS mm (inches)
TOLERANCE OF ±3 mm (±0.125") SHOULD BE USED.
B C D S SD T
FOR EXACT INSTALLATION DATA PLEASE WRITE FACTORY FOR CERTIFIED DIMENSIONS.
SEE PERFORMANCE CURVES ON PAGE 2. 245 (9.63) 194 (7.63) 381 (15.00) 432 (17.00) 813 (32.00) 222 (8.75)
Page 1 of 2
PERFORMANCE CURVES
Performance Guaranteed Only At Operating Point Indicated
CURVE SHOWN FOR CLEAR, COLD WATER - SP. GR. 1.0
Head (ft) m CURVE NO.
10.19 in 39 53 64
72
77
3000 RPM PT103-1-0-3000
80
(262.5) 80 SERIES
9.50 in 81
80 4300
9.00 in 77
(210.0) 64 SIZE
8.50 in 72
6x6x10
8.00 in 64
(157.5) 48 RPM
100 hp 3000
75 hp
(105.0) 32 BHP based on
60 hp shown Fluid’s sp. gr.
50 hp
40 hp 4300
A
(52.5) 16 P
N 30 hp V All Ratings
25 hp A
S I
H L
r NPSHr A
(0.0) 0 B
I
0 80 160 240 320 400 (m‡/h) L
0.00 22.22 44.45 66.67 88.90 111.12 (lps) I
T
Flow Y
Water, sg= 1.00
(65.6) 20 9.50 in 83
SERIES
84
83
4300
9.00 in 4380
81
(52.5) 16 8.50 in SIZE
76
8.00 in 6x6x10
68
(39.4) 12 RPM
56 15 hp 1500
5 hp A 4300
(13.1) 4 P
N V All Ratings
3 hp A
S I 4380
H L
NPSHr A All Ratings
r
(0.0) 0 B
I
0 40 80 120 160 200 (m‡/h) L
0.00 11.11 22.22 33.34 44.45 55.56 (lps) I
T
Flow Y
Water, sg= 1.00