Onyx pump vs.

DGF pump
Onyx (GLR) DGF (Siemens)

Closest Design Standard API 610 Manufacturers Standard (Cornell Pumps)

Number of Stages (60/50 hz) 2/3 1/1


Self Induction of Gas Yes Yes
Bearing Configuration Between bearings No bearings
Oil lubricated brgs, convertible to grease if
Lubrication No lubrication other than pumped fluid
required
Seal Arrangement Mechanical Seal SiC/SiC Gland
Plan 11 w/ capability to handle double
Seal Flush Plan mechanical seals
seals, alternative flush plans ?
available
Seal & Bearing Change Out Replaced with pump and motor in place Requires removal of motor and subsequent realignment
Mounting Configuration Horizontal w/ Flexible Coupling Overhung – Close Coupled
Suction/Discharge Nozzles 150# 150#
Suction/Discharge Nozzle Configuration Top/Top (high nozzle load capability) Front/Side (low nozzle load capability)
Motor HP (200 gpm model) 30 30
Motor RPM (60 hz) 3500 3600
Interstage Elastomers Viton Standard (alternatives available) NA
Impeller Open, floating Closed , fixed
S.S. ASTM 351/A743/A744, CD4MCu Duplex,
Casing Materials Available ?
Super Duplex & Hastelloy C
Bubble Size < 50 Micron Diameter 32 Micron Diameter
Pump
u p Sta
Standard
da d Discharge
sc a ge Pressure
essu e (60 hz)) 100
00 ps
psi 65 ps
psi
Gas Saturation Efficiency 1.6 Ibs/1,000 gallons 1.14 lbs/1,000 gallons