Download as pdf or txt
Download as pdf or txt
You are on page 1of 20

BuckeyeCOMPLETE:Layout 1 5/24/07 4:06 PM Page 1

BUCKEYE FIRE EQUIPMENT


American Made
Since 1968

2007 Fire Equipment


Product Catalog
www.buckeyef.com
BuckeyeCOMPLETE:Layout 1 5/24/07 4:06 PM Page 2

Company and Product Profile

Buckeye Fire Equipment We mill and blend our own dry chemical agents
(monoammonium phosphate based [ABC],
A Tradition of Innovation and potassium bicarbonate based [Purple K], and
Reliability sodium bicarbonate based [Standard]) on site
where each batch is tested and verified to meet
In the fire protection industry for over 35 years, our in-house and UL quality requirements. In our
the Buckeye Fire Equipment Company is an machining centers we produce our cylinders and
innovative manufacturer of a complete line of valve component parts to exacting standards that
Underwriters Laboratories (UL) Listed fire are quality-assured by a manufacturing and
protection products: inspection system certified to the latest revision
of the ISO 9001 Quality Standard. On one of the
• Portable and wheeled fire extinguishers most modern automated process lines in the
• Dry chemical extinguishing agents world, the extinguishers are filled, pressurized,
• Firefighting foam concentrates and foam and leak tested to assure that only the highest
hardware quality extinguishers reach our customers.
• Engineered restaurant fire suppression
systems

At our 165,000 square foot manufacturing


facility located near Charlotte, North Carolina,
Buckeye Fire Equipment produces high quality
and reliable fire protection equipment for
national and international markets. With sales
and warehouse centers strategically located
throughout the United States, as well as a global
network of authorized distributors, Buckeye Fire
Equipment is ready to provide its customers with
timely and efficient sales, delivery, and service.
ABC Fire Extinguisher at Work
Buckeye Fire Equipment also manufactures a
Fire Extinguishers wide selection of hazard specific fire
Portable Hand and Wheeled extinguishers to meet your individual fire
protection needs. These include clean gas
At the heart of the Buckeye Fire Equipment extinguishers such as Carbon Dioxide and
product lines are the hand-portable dry chemical Halotron™, the Class K Wet Chemical
fire extinguishers. The performance reliability of extinguishers used for kitchen fire suppression,
these extinguishers is a direct result of the Class D extinguishers for use on metal fires, and
stringent controls under which each component the Water Mist extinguishers suitable for use on
is produced. Class A fires where a Class C hazard may also
exist.
BuckeyeCOMPLETE 5/24/07 4:53 PM Page 3

If your situation requires more fire-stopping


power, Buckeye offers clean gas agents and all
three of our dry chemical agents in easily
Buckeye Kitchen Mister
transportable wheeled units. Depending on the
extinguishing agent you select, these wheeled
UL 300 Restaurant
units are available in capacities ranging from 50 Fire Suppression System
lbs. to 350 lbs. Please refer to the Catalogue
Product Tables for the models and sizes offered.

Firefighting Foams and Hardware


With one of the world’s largest capacity foam
blending operations, Buckeye Fire Equipment
produces a comprehensive line of firefighting
foam concentrates recognized through
independent tests as among the best in the
industry.

Our wide array of foam concentrates assures that


there is one designed to meet your fire Buckeye Fire Equipment is proud to introduce
suppression requirements. the next generation of UL-300 Restaurant
Cooking Area Fire Suppression Systems, the
As committed as we are to the quality and Buckeye Kitchen Mister Suppression System.
performance of our foam concentrates, we are
also committed to protecting the environment - Although many restaurant systems brag about
our foam concentrates are manufactured without product innovation, improved technology, fire
any EPA reportable components. fighting ability, and “ease of installation”, the
Buckeye Kitchen Mister is the first product to
truly deliver on that promise.

By combining the fire fighting ability of misting


technology, common sense features, and time
saving patented innovations, the Kitchen Mister
makes all other systems seem complicated and
outdated.

If reducing installation time by up to 50% is


important to you, then your system has arrived.

Knocking Down the Fire with


Buckeye Foam Buckeye Fire Equipment
Research and Development Center
To complement the firefighting foam product
line, Buckeye Fire Equipment manufactures Customer Driven to Serve You
foam storage, proportioning, and delivery
hardware that can be engineered for your specific Buckeye Fire Equipment is a customer driven
needs. This hardware may be used in both fixed company that prides itself on earning your
or portable system installations. Our expert business with every call. If you have questions
technical staff can assist you in determining the about any of the products in this catalogue please
most effective application for your potential do not hesitate to contact us.
hazard.
BuckeyeCOMPLETE:Layout 1 5/24/07 4:07 PM Page 4

Portable Extinguisher extinguishing potential of the fire


extinguisher and is developed on the basis of
Selection Guide comparative fire tests (Reference UL 711,
Standard for Rating and Testing of Fire
Extinguishers). Only the Class A and Class
The National Fire Protection Association B classifications carry numerical ratings.
(NFPA) has established the requirements for Basically, the higher the number associated
the number, size, placement, performance, with the classification letter, the larger the
and maintenance of portable fire fire the extinguisher has the potential to put
extinguishers. These requirements are out. Please refer to NFPA 10 when
contained in NFPA 10, “Standard for determining the rating necessary for the
Portable Fire Extinguishers”. Within this floor area requiring protection.
Standard it is stated that the selection of fire
extinguishers for a given situation is There are no numerical ratings associated
determined by the character of the fires with Class C, D, or K classifications.
anticipated to be encountered, the Comparative fire tests are not conducted. In
construction and occupancy of the property the case of Class C, the electrical
to be protected, the ambient temperature of nonconducting characteristics of the agent
the area where the extinguisher will be are verified, not the extinguishing potential.
located, and other factors that may dictate For Class D, only the amount of agent and
the selection of a particular type of application method needed to control a
extinguisher. metal fire of a certain size and type is tested.
And for Class K, the fire extinguishing
CLASSIFICATION characteristics of the extinguisher have only
been determined for a single size fire source.
Generally, fire extinguishers are selected In the typical rating of an extinguisher, for
based on the hazard(s) they are intended to example 3A-40B:C, the 3 and the 40
protect. Classifications have been indicate the extinguishing potential of the
established to categorize what type of unit for a Class A and Class B fire
extinguishing agent is best suited for the fire respectively. The C indicates that the
hazard. These classifications are A, B, C, D, extinguishing agent will not conduct
and K. electricity, preventing shock to the user if
used on energized electrical equipment.
A fire extinguisher assigned a Class A
classification is suitable for use on ordinary On the following page is a reference chart
combustibles; wood, paper, cloth, rubber, with the basic rating parameters for
and many of the plastics. The B extinguishers.
classification is intended for use on
flammable liquids, combustible liquids, SUMMARY
petroleum greases, oils, oil-based paints,
solvents, alcohols, and flammable gases. To provide the best protection of life and
Class C extinguishers are for use on fires property from the destructive force of fire, it
involving energized electrical equipment. is critical that the proper fire extinguisher
For fires involving combustible metals selection be made. The Classification and
(magnesium, lithium, zirconium, etc.), Class Rating of an extinguisher are vital pieces of
D extinguishers are best to use. An information for making that selection.
extinguisher designated Class K best
protects cooking appliances that utilize Using NFPA 10 for guidance, matching the
cooking media such as vegetable oils and right fire extinguisher to the potential
animal fats. hazard, providing a sufficient number of
extinguishers for the area to be protected,
RATING locating the extinguishers for maximum
visibility and accessibility, and personnel
Along with the classification, the numerical trained in the use and maintenance of the
rating of an extinguisher is an important extinguisher will significantly lessen the risk
factor in the proper selection of an of loss.
extinguisher. The rating is a measure of the
BuckeyeCOMPLETE:Layout 1 5/24/07 4:07 PM Page 5

EXTINGUISHER PLACEMENT
AND RATING REFERENCE CHARTS

Placement/Accessibility Of Extinguisher
CLASS A CLASS B CLASS C CLASS D CLASS K
FIRE HAZARD FIRE HAZARD FIRE HAZARD FIRE HAZARD FIRE HAZARD
MAXIMUM 75 Feet 50 Feet 30 Feet
Maximum area that one Maximum area that one
In accordance with Maximum area that one
TRAVEL extinguisher can protect extinguisher can protect the Class A or B 75 Feet extinguisher can protect
DISTANCE and meet the 75’ rule and meet the 50’ rule hazard it is protecting and meet the 30’ rule
= 11,250 sq. ft. = 5000 sq. ft. = 1800 sq. ft.

Basic Extinguisher Rating Parameters


ORDINARY COMBUSTIBLES FLAMMABLE LIQUIDS ENERGIZED COOKING
ELECTRICAL MEDIA
Class A Fires Class B Fires
(Wood, Paper, Cloth, Rubber) (Gasoline, Oil, Paints, Solvents, Propane) Class C Fires Class K Fires
(Computers, (Cooking
Electrical Panels, Appliances)
Transformers)
Numerical Wood Wood Crib Fire Test Numerical Minimum Fire Test Estimated
Rating Panel Rating Discharge Pan Size Novice NO FIRE TEST Fire Test Fryer Size
Fire Test Overall Dims. No. of Trade Size of Required (expert) Capability
(inches) Members Members (inches) Extinguishing agent is 18”x24”x18”
1A 8’x 8’ 20 x 20 x 18 72 2 x 2 x 20 2B 8 Sec 5 sq ft 5 sq ft tested for electrical Deep Fat Fryer
2A 10’x 10’ 25 x 25 x 24 112 2 x 2 x 25 5B 8* Sec 12.5 sq ft 10 sq ft nonconductivity. If
3A 12’x 12’ 29 x 29 x 27 144 2 x 2 x 29 10B 8* Sec 25 sq ft 20 sq ft nonconductive, the “C” No numerical rating
4A 14’x 14’ 32 x 32 x 30 180 2 x 2 x 32 20B 8* sec 50 sq ft 40 sq ft symbol is added to the is given for Class K
6A 17’x 17’ 36 x 36 x 34.5 230 2 x 2 x 36 40B 13 Sec 100 sq ft 60 sq ft existing classification.
Discharge Time
10A N/A 43 x 43 x 40.5 324 2 x 2 x 43 60B 17 Sec 150 sq ft 80 sq ft
No numerical rating Approx. 60 Seconds
20A N/A 55 x 55 x 57.5 256 2 x 4 x 55 80B 20 Sec 200 sq ft 80 sq ft
is given for Class C
30A N/A 64 x 64 x 64.5 324 2 x 4 x 64 120B 26 Sec 300 sq ft 120 sq ft
40A N/A 69 x 69 x 71.5 400 2 x 4 x 69 160B 31 Sec 400 sq ft 160 sq ft
*13 Seconds
with an “A” rating

There are three general classifications of hazard areas- low, ordinary, and extra.
Minimum rating required for low or ordinary hazard areas is 2A.
Minimum rating for extra hazard areas is 4A.

Maximum floor area that can be protected per unit of A is 3,000 sq. ft. for low hazard.
Maximum floor area that can be protected per unit of A is 1,500 sq. ft. for ordinary hazard.
Maximum floor area that can be protected per unit of A is 1,000 sq. ft. for extra hazard.

To determine the rating necessary for proper protection, divide the total sq. ft. by the unit of A for the hazard.

Example: An extinguisher is needed to protect an office area (low hazard) that measures 10,500 sq. ft.
Total sq. ft. = 10,500. Unit of A for low hazard is 3,000. The rating necessary to protect the area is
10,500 ÷ 3,000 = 3.5 units of A. Rounding up to the next numerical rating would mean that a 4A-rated
extinguisher would be needed to protect the office.

If the area were classified as “extra hazard” then the extinguisher would need to be rated 20A
(10,500 ÷ 1,000 = 10.5 units of A. Rounded up to the next numerical rating = 20A).
BuckeyeCOMPLETE:Layout 1 5/25/07 11:01 AM Page 6

ABC DRY CHEMICAL


HAND HELD
STORED PRESSURE FIRE EXTINGUISHERS

FEATURES:
• Monoammonium Phosphate based dry chemical agent.
• Rated for use on “A”, “B”, and “C” class fires. Provides the widest, most practical range of fire protection.
• Rechargeable
• Steel cylinders with a baked-on polyester enamel coating stand up to harsh environments.
• Manufactured to ANSI/UL 299 and ANSI/UL 711 Standards
• Optional brass valves on some units. 30 lb. unit has brass valve only

TYPICAL USES: Offices, warehouses, woodworking areas, farms, general public assembly areas, and homes. The ABC extinguisher
is not recommended for use on sensitive electronic equipment or aircraft structure.

Model 2.5 ABC 5 ABC 5 ABC 10 TALL 10S ABC 20S ABC 30S ABC
V/B V/B ABC
Part #
Alum. Valve 13315 10914 25614 11340 11310 12120 N/A
Part #
Brass Valve N/A 10915 25615 11341 N/A 12121 12905
Agent 2.5 lb. 5 lb. 10 lb. 20 lb. 30 lb.
Capacity (1.13 kg) (2.27 kg) (4.54 kg) (9.07 kg) (13.6 kg)
UL Rating 1A-10B:C 3A-40B:C 4A-80B:C 4A-60B:C 20A-120B:C 20A-160B:C
Discharge Time 9 sec 14 sec 22 sec 18 sec 26 sec 32 sec
Range (ft/m) 9-15 / 2.7-4.6 12-18 / 3.7-5.5 15-21 / 4.6-6.4 25-30 / 7.6-9.1
Operating 100 psi 195 psi
Pressure (689 kPa) (1344 kPa)
Bracket Vehicle Wall Vehicle Wall
USCG Approval Type B:C Size I Type A Size II Type A Size II Type A Size II Type A Size II
Type B:C Size I Type B:C Size II Type B:C Size III Type B:C Size IV
Ship Wt. 5.5 lbs. 10 lbs. 10.25 lbs 18.25 lbs. 18.75 lbs. 33.5 lbs. 52.25 lbs.
(2.5 kg) (4.5 kg) (4.7 kg) (8.3 kg) (8.6 kg) (15.2 kg) (23.7 kg)
Height 14.75 in 16.375 in 21 in 16.75 in 21.25 in 27.375 in
(37.5 cm) (41.6 cm) (53.3 cm) (42.5 cm) (53.8 cm) (69.4 cm)
Width 4.875 in 7.25 in 7.75 in 8.25 in 8.75 in
(12.4 cm) (18.4 cm) (19.7 cm) (21 cm) (22.2 cm)
Diameter 3.375 in 4.25 in 5.125 in 6 in 7.5 in
(8.6 cm) (10.8 cm) (13 cm) (15.2 cm) (19.1 cm)
BuckeyeCOMPLETE:Layout 1 5/25/07 11:01 AM Page 7

STANDARD DRY CHEMICAL


HAND HELD
STORED PRESSURE FIRE EXTINGUISHERS

FEATURES:
• Sodium Bicarbonate based dry chemical agent.
• Rated for use on “B” and “C” Class fires.
• Rechargeable
• Steel cylinder with a baked-on polyester enamel coating stands up to harsh environments.
• Manufactured to ANSI/UL 299 and ANSI/UL 711 Standards.

TYPICAL USES: Kitchens, garages, boats, vehicles, and extinguisher use training.
The Standard extinguisher is not recommended for use on sensitive electronic equipment.

Model 2.5 STD V/B 5.5 STD 5.5 STD V/B 10 STD 20S STD
Part # Aluminum Valve 13415 11014 13514 11840 12220
Agent 2.5 lbs. 5.5 lbs. 10 lbs. 20 lbs.
Capacity (1.13 kg) (2.50 kg) (4.54 kg) (9.07 kg)
UL Rating 10 B:C 40 B:C 120 B:C
Discharge Time 9 seconds 14 seconds 26 seconds
Range 9-15 ft 12-18 ft 15-21 ft
(2.7-4.6 m) (3.7-5.5 m) (4.6-6.4 m)
Operating 100 psi 195 psi
Pressure (689 kPa) (1344 kPa)
Bracket Vehicle Wall Vehicle Wall
USCG Approval Type B:C Size I Type B:C Size II Type B:C Size III
Ship Wt. 5.5 lbs. 10.5 lbs. 10.75 lbs. 18.25 lbs. 33.5 lbs.
(2.5 kg) (4.8 kg) (4.9 kg) (8.3 kg) (15.2 kg)
Height 14.75 in 16.375 in 21 in 21.25 in
(37.5 cm) (41.6 cm) (53.3 cm) (53.8 cm)
Width 4.875 in 7.25 in 7.75 in 8.75 in
(12.4 cm) (18.4 cm) (19.7 cm) (22.2 cm)
Diameter 3.375 in 4.25 in 5.125 in 7.5 in
(8.6 cm) (10.8 cm) (13 cm) (19.1 cm)
BuckeyeCOMPLETE:Layout 1 5/25/07 11:01 AM Page 8

PURPLE K DRY CHEMICAL


HAND HELD
STORED PRESSURE FIRE EXTINGUISHERS

FEATURES:
• Potassium Bicarbonate based dry chemical agent.
• Rated for use on “B”, and “C” class fires. Most effective dry chemical agent for Class B fires
• Rechargeable
• Steel cylinder with a baked-on polyester enamel coating stands up to harsh environments.
• Manufactured to ANSI/UL 299 and ANSI/UL 711 Standards
• Optional brass valves on some units. 30 lb. unit has brass valve exclusively.

TYPICAL USES: Garages, service bays, boats, vehicles, fuel storage and transfer areas.
The Purple K extinguisher is not recommended for use on sensitive electronic equipment.

Model 2.5 PK V/B 5 PK 5 PK V/B 10 PK 20S PK 30S PK


Part # 13515 11214 25914 11740 12620 N/A
Alum. Valve
Part # N/A N/A N/A N/A 12621 12805
Brass Valve
Agent 2.5 lbs 5 lbs. 10 lbs 20 lbs. 30 lbs.
Capacity (1.13 kg) (2.27 kg) (4.54 kg) (9.07 kg) (13.6 kg)
UL Rating 10 B:C 20 B:C 80 B:C 120 B:C 160 B:C
Discharge 9 seconds 22 seconds 26 seconds 32 seconds
Time
Range 9-15 ft 12-18 ft 15-21 ft 25-30 ft
(2.7-4.6 m) (3.7-5.5 m) (4.6-6.4 m) (7.6-9.1 m)
Operating 100 psi 195 psi
Pressure (689 kPa) (1344 kPa)
Bracket Vehicle Wall Vehicle Wall
USCG Type B:C Size I Type B:C Size II Type B:C Size III Type B:C Size IV
Approval
Ship Wt. 5.5 lbs 10 lbs. 10.25 lbs. 18.25 lbs. 33.5 lbs. 52.25 lbs.
(2.49 kg) (4.5 kg) (4.6 kg) (8.3 kg) (15.2 kg) (23.7 kg)
Height 14.75 in 16.375 in 21 in 21.25 in 27.375 lbs.
(37.5 cm) (41.6 cm) (53.3 cm) (53.8 cm) (69.4 cm)
Width 4.875 in 7.25 in 7.75 in 8.75 in
(12.4 cm) (18.4 cm) (19.7 cm) (22.2 cm)
Diameter 3.375 in 4.25 in 5.125 in 7.5 in
(8.6 cm) (10.8 cm) (13 cm) (19.1 cm)
BuckeyeCOMPLETE:Layout 1 5/25/07 11:02 AM Page 9

HALOTRON™
HAND HELD AND WHEELED
STORED PRESSURE FIRE EXTINGUISHERS

FEATURES:
• Residue-free Hydrochlorofluorocarbon gas agent pressurized with argon.
• Excellent replacement for Halon 1211 extinguishers.
• Rechargeable steel cylinders with baked-on polyester enamel coating that stands up to harsh environments.
Wheeled units have DOT approved 4BW240 cylinders, rugged frames, and semi-pneumatic tires.
• All units are manufactured to ANSI/UL 2129 and ANSI/UL 711 Standards.
• Optional chrome-plated brass valves on some units (standard on Wheeled Extinguishers).

TYPICAL USES: Computer rooms, telephone switch rooms, data storage areas, boats, and flight lines.

Model 2.5F 2.5F 2.5H 2.5H 5F 5F V/B 5H 5H V/B 11 15


V/B V/B
Part # 70258 70251 70259 70256 70510 70550 75550 75555 71100 71550
Alum. Valve
Part # Not 70511 70551 75551 75556 71101 71551
Brass Valve Available
Agent Capacity 2.5 lbs 5 lbs. 5.5 lbs. 11 lbs. 15.5 lbs.
(1.13 kg) (2.27 kg) (2.49 kg) (5 kg) (7.03 kg)
UL Rating 2B:C 5B:C 1A-10B:C 2A-10B:C
Discharge Time 9 seconds 13 seconds
Range 6-10 ft 9-15 ft 12-18 ft
(1.8-3 m) (2.7-4.5 m) (3.7-5.5 m)
Operating 100 psi 125 psi
Pressure (689 kPa) (862 kPa)
Bracket Wall Vehicle Wall Vehicle Wall Vehicle Wall Vehicle Wall
USCG Not Applicable Type B:C Type B:C
Approval Size I Size II
Ship Wt. 5.25 lbs 5.5 lbs. 5.75 lbs 9.25 lbs. 9.5 lbs. 10 lbs. 10.25 lbs. 21.25 lbs. 25.75 lbs.
(2.4 kg) (2.49 kg) (2.6 kg) (4.2 kg) (4.3kg) (4.5 kg) (4.7 kg) (9.6 kg) (11.7 kg)
Height 13.375 in (34 cm) 16.375 in (41.6 cm) 17.5 in (44.5 cm)
Width 5.625 in 6.75 in 6.5 in 7.25 in 6.5 in 7.25 in 8.625 in
(14.3 cm) (17.1 cm) (16.5 cm) (18.4 cm) (16.5 cm) (18.4 cm) (21.9 cm)
Diameter 3.375 in (8.6 cm) 4.25 in (10.8 cm) 7 in (17.8 cm)

Wheeled Extinguishers
Model Part # Capacity UL Discharge Range Unit Hose Ship
Rating Time Height x Width x Depth Diameter x Length Weight
W-65 76500 65 lbs 4A-40B:C 17 15-25 ft 50 x 24 x 41.5 in .75 in x 25 ft 300 lbs
(29.5 kg) seconds (4.6-7.6 m) (127 x 61 x 105 cm) (1.9 cm x 7.6 m) (136 kg)
W-150 71500 150 lbs 10A-80B:C 23 23-36 ft 62 x 24 x 41.5 in 1 in x 40 ft 480 lbs
(68 kg) seconds (7-10.7 m) (157.5 x61 x 105 cm) (2.5 cm x 12.2 m) (218 kg)
BuckeyeCOMPLETE:Layout 1 5/25/07 11:02 AM Page 10

CARBON DIOXIDE
HAND-HELD AND WHEELED
FIRE EXTINGUISHERS

FEATURES:
• Residue-free carbon dioxide gas extinguishing agent.
• Hand-held units use aluminum cylinders with a baked-on polyester enamel coating to withstand harsh
environments.
• Wheeled units are constructed with spun steel cylinders, rugged frames, and pneumatic tires and are
designed to be easily operated by one person.
• All units manufactured to ANSI/UL 154 and ANSI/UL 711 Standards and use DOT compliant cylinders.
• Plated brass valves on both hand-held and wheeled units.
• Optional tow loops offered on the wheeled extinguishers.

TYPICAL USES: Refineries, shipboard, laboratories, construction sites, chemical plants, and manufacturing
facilities.

Hand-Held Extinguishers
Model 5CD 10CD 15CD 20CD
Part Number 45100 45600 46100 46600
Agent Capacity 5 lbs. (2.27 kg) 10 lbs. (4.54 kg) 15 lbs. (6.80 kg) 20 lbs. (9.07 kg)
UL Rating 5B:C 10B:C
Discharge Time 8 seconds 10 seconds 15 seconds 20 seconds
Range 4-8 ft (1.2-2.4 m)
Bracket Wall
USCG Approval Type B:C Size I Type B:C Size II
Ship Wt. 13.75 lbs. (6.3 kg) 27.75 lbs. (12.6 kg) 37.75 lbs. (17.1 kg) 49.0 lbs. (22.2 kg)
Height 17.375 in (44.1 cm) 19.75 in (50.2 cm) 26.375 in. (67 cm) 26.875 in (68.2 cm)
Width 8.25 in (21 cm) 12 in (30.5 cm) 13 in (33 cm)
Diameter 5.25 in (13.3 cm) 6.89 in (17.5 cm) 8 in (20.3 cm)

Wheeled Extinguishers
Model Part # Capacity UL Discharge Range Unit Hose Ship
Rating Time Height x Width x Depth Dia x Length Weight
C-50-SE 35050 50 lbs. 40 60 x 30 x 21 in 1 in x 15 ft 250 lbs.
(22.68 kg) seconds 15 ft (152.4 x 76.2 x 53.3 cm) (2.5 cm x 4.56 m) (113.4 kg)
20B:C
C-100-SE 35100 100 lbs. 80 (4.6m) 65 x 30 x 21 in 1 in x 40 ft 390 lbs.
(45.36 kg) seconds (165.1 x 76.2 x 53.3 cm) (2.5 cm x 12.2 m) (176.9 kg)
BuckeyeCOMPLETE:Layout 1 5/25/07 11:02 AM Page 11

AUTOMATIC SPOT
PROTECTION
FEATURES:
• Designed to provide supplemental protection suitable for some local and total flood applications.
• Two mount styles available, charged with multipurpose dry chemical (ABC) or clean agent Halotron™.
• The cylinders are constructed and tested to the same engineering standards as our portable extinguishers.
• These units are not Underwriters Laboratories Listed and are not intended for use in lieu of an engineered
system. They are not to be multiple mounted.

VERTICAL MOUNT STYLE

Agent Multipurpose ABC Dry Chemical Halotron™


Part No. 80250 80501 81001 82001 87100 87200
Capacity (lb./kg) 2.5 lbs/ 1.13 kg 5 lbs/ 2.3 kg 10 lbs/ 4.5 kg 20 lbs/ 9.1 kg 18 lbs/ 8.2 kg 25 lbs/ 11.3 kg
Ship Wt. (lb./kg) 4 lbs/ 1.8 kg 11 lbs/ 5.0 kg 19 lbs/ 8.6 kg 36 lbs/ 16.3 kg 29 lbs/ 13.2 kg 42 lbs/ 19.0 kg
Operating Pressure 100 psi (689 kPa) 195 psi (1344 kPa) 100 psi (689 kPa)
Length 15.25 in 17.25 in 17.625 in 21.875 in 17.875 in 21.875 in
Diameter 3.375 in 4.25 in 6.0 in 7.5 in 7.0 in 7.5 in
Max Total Flood-
Volume 120 cu ft 180 cu ft 1300 cu ft 2184 cu ft 500 cu ft 700 cu ft
Max Total Flood-
Height above Hazard 7.5 ft 13 ft 14 ft 8 ft 10 ft
Local Application
Coverage Areas 4 ft x 4 ft 4 ft x 6 ft 10 ft x 10 ft 12 ft x 13 ft 4 ft x 4 ft 6 ft x 6 ft
Max Local Application- Height Above Hazard = 4 feet for all models

HORIZONTAL MOUNT STYLE

Agent Multipurpose ABC dry chemical Halotron™


Part No. 80251 80521 81021 82021 87105 87205
Capacity (lb./kg) 2.5 lbs/ 1.13 kg 5 lbs/ 2.3 kg 10 lbs/ 4.5 kg 20 lbs/ 9.1 kg 18 lbs/ 8.2 kg 25 lbs/11.3 kg
Ship Wt. (lb./kg) 4 lbs/ 1.8 kg 11 lbs/ 5.0 kg 19 lbs/ 8.6 kg 36 lbs/ 16.3 kg 29 lbs/ 13.2 kg 42 lbs/ 19.0 kg
Operating Pressure 100 psi (689 kPa) 195 psi (1344 kPa) 100 psi (689 kPa)
Length 14.25 in 17.25 in 20.875 in 21.875 in 17.875 in 21.875 in
Diameter 3.375 in 4.25 in 5.125 in 7.5 in 7.0 in 7.5 in
Max Total Flood-
Volume 120 cu ft 180 cu ft 1300 cu ft 2184 cu ft 500 cu ft 700 cu ft
Max Total Flood-
Height above Hazard 7.5 ft 13 ft 14 ft 8 ft 10 ft
Local Application
Coverage Areas 4 ft x 4 ft 4 ft x 6 ft 10 ft x 10 ft 12 ft x 13 ft 4 ft x 4 ft 6 ft x 6 ft
Mounting Bracket 700287 700270 700226 700229 700228 700229
Max Local Application- Height Above Hazard = 4 feet for all models
BuckeyeCOMPLETE:Layout 1 5/25/07 11:02 AM Page 12

DRY CHEMICAL
WHEELED FIRE EXTINGUISHERS

FEATURES:

• Three choices in dry chemical agents are available to suit your particular fire protection needs:
Monoammonium Phosphate (ABC), Sodium Bicarbonate (Standard), and Potassium Bicarbonate (Purple K).
• The ABC extinguisher is rated for use on “A”, “B”, and “C” class fires, providing the widest, most practical
range of fire protection. The Standard and Purple K extinguishers are rated for use on B:C classes of fires.
• Designed for one-man operation. Easily transported through doorways and over rough terrain.
• All models are also available as stationary units.
• Every model is rechargeable.
• Rugged steel cylinders and frames with baked-on polyester enamel coatings stand up to harsh environments.
• Manufactured to ANSI/UL 299 and ANSI/UL 711 Standards.
• Plated brass cylinder valves and hose valve assemblies.
• All pressurized cylinders are DOT approved. Extinguishers part numbered 30010, 30110, 30030, 30310, &
31210 are USCG approved.

TYPICAL USES: Offshore rigs, ship docks, refineries, chemical plants, aircraft ramps, remote construction sites, large
laboratories, processing plants, storage and loading areas.
These extinguishers are not recommended for use on sensitive electronic equipment.

WHEELED EXTINGUISHER PHYSICAL ATTRIBUTES


MODEL PART SHIP HEIGHT WIDTH DEPTH HOSE WHEEL
NO. WEIGHT LENGTH x DIA DIAMETER
A-50-SP 30010 193 lbs. 47 inches 24 inches 26.5 inches 25 ft. x .50 in 12.3 x 3.5 in
K-50-SP 30030 (88 kg) (119 cm) (61 cm) (67 cm) (7.6 m x 1.3 cm) (31.3 x 8.9 cm)
A-150-SP 30110 343 lbs. 51 inches 26 inches 38 inches
K-150-SP 30310 (156 kg) (128 cm) (66 cm) (96.5 cm)
A-150-RG 31120 413 lbs. 16 x 4 in
K-150-RG 31320 (188 kg) 50 inches 24 inches 42 inches (40.6 x 10.2 cm)
438 lbs. (127 cm) (61 cm) (105 cm)
S-150-RG 31220
(199 kg)
A-150-RG 31140* 36 x 2.5 in
31150** 448 lbs. (91.4 x 6.4 cm)
50 ft x .75 in
31340* (204 kg) 55 inches 32 inches 46 inches
K-150-RG (15.2 m x 1.9 cm) * Steel Wheels
31350** (139 cm) (81.3 cm) (117 cm)
31240* 473 lbs. ** Steel wheels with
S-150-RG
31250** (215 kg) rubber tread
A-150-PT 31110 345 lbs.
K-150-PT 31310 (157 kg) 50 inches 24 inches 42 inches 16 x 4 in
(127 cm) (61 cm) (105 cm) (40.6 x 10.2 cm)
S-150-PT 31210 370 lbs.
(168 kg)
32120*
A-350-RG 32140** 810 lbs.
32320* (368 kg) 36 x 2.5 in
K-350-RG 32340** (91.4 x 6.4 cm)
32220* 860 lbs.
S-350-RG 32240** (391 kg) * Steel Wheels
32110* 58 inches 36 inches 48 inches 50 ft x 1 in
A-350-PT (147 cm) (91.4 cm) (122 cm) (15.2 m x 2.5 cm) ** Steel wheels with
32130** 700 lbs. rubber tread
32310* (318 kg)
K-350-PT 32330**
S-350-PT 32210* 750 lbs.
32230** (341 kg)
BuckeyeCOMPLETE:Layout 1 5/25/07 11:02 AM Page 13

ABC WHEELED EXTINGHUISHER PERFORMANCE SPECIFICATIONS


MODEL PART NO. AGENT CAPACITY UL RATING DISCHARGE DISCHARGE
TIME RANGE
A-50-SP 30010 50 lbs. 30A-160B:C 35 seconds 25-35 ft
(22.7 kg) (7.6-10.7 m)
A-150-SP 30110 47 seconds
31120
A-150-RG 31140 125 lbs. 40A-240B:C 43 seconds
31150 (56.7 kg)
A-150-PT 31110 45 seconds 30-40 ft
(9.1-12.2 m)
32120
A-350-RG 300 lbs. 53 seconds
32140 40A-320B:C
32110 (136 kg)
A-350-PT 57 seconds
32130

PURPLE K WHEELED EXTINGHUISHER PERFORMANCE SPECIFICATIONS


MODEL PART NO. AGENT CAPACITY UL RATING DISCHARGE DISCHARGE
TIME RANGE
K-50-SP 30030 50 lbs. 160 B:C 25-35 ft
34 seconds
(22.7 kg) (7.6-10.7 m)
K-150-SP 30310 54 seconds
31320
K-150-RG 31340 125 lbs. 57 seconds
31350 (56.7 kg)
30-40 ft
K-150-PT 31310 54 seconds
320B:C (9.1-12.2 m)
32320
K-350-RG 300 lbs. 56 seconds
32340
32310 (136 kg)
K-350-PT 58 seconds
32330

STANDARD WHEELED EXTINGHUISHER PERFORMANCE SPECIFICATIONS


MODEL PART NO. AGENT CAPACITY UL RATING DISCHARGE DISCHARGE
TIME RANGE
31220
S-150-RG 31240 150 lbs. 240B:C 48 seconds
31250 (68 kg)
S-150-PT 31210 43 seconds 30-40 ft
32220 (9.1-12.2 m)
S-350-RG 32240 350 lbs. 59 seconds
32210 (159 kg) 320B:C
S-350-PT 50 seconds
32230
BuckeyeCOMPLETE:Layout 1 5/25/07 11:02 AM Page 14

SPECIALTY
FIRE EXTINGUISHERS

WET CHEMICAL – CLASS K


• Contains a blend of Potassium Acetate and Potassium Citrate that is extremely effective
in suppressing high temperature fires fueled by the unsaturated cooking oils used in
today’s restaurant appliances. The agent is applied by a misting discharge nozzle that
prevents the splashing and spreading of the oils. This extinguisher is designed to
complement existing pre-engineered hood systems. Also carries an “A” Rating.

• Manufactured to ANSI/UL 8 and ANSI/UL 711 Standards.

Model WC-6 Liter


Part # 50006
Agent Capacity 6 Liter (1.59 gallons)
UL Rating 1-A:K (Tested to extinguish one 18” X 24” fryer)
Discharge Time 54 seconds
Operating Pressure 100 psi (689 kPa)
Bracket Wall
Ship Wt. 22 lbs. (10 kg)
Height 19.25 inches (48.9 cm)
Width (including hose) 9 inches (22.9 cm)
Cylinder Diameter 7 inches (17.8 cm)
Construction Stainless steel cylinder with plated brass valve

WATER
• Uses water as the extinguishing agent. This economical and environmentally friendly
extinguisher is ideal for schools, theaters, retail storerooms, and anywhere Class A
hazards exist.

• Manufactured to ANSI/UL 8 and ANSI/UL 711 Standards.

Model 500
Part # 50000
Agent Capacity 2.5 gallon (9.6 liters)
UL Rating 2A
Discharge Time 50 seconds
Operating Pressure 100 psi (689 kPa)
Bracket Wall
Ship Wt. (empty) 7.75 lbs. (3.5 kg)
Height 24.5 inches (62.2 cm)
Width (including hose) 9 inches (22.9 cm)
Cylinder Diameter 7 inches (17.8 cm)
Construction Stainless steel cylinder with plated brass valve
BuckeyeCOMPLETE:Layout 1 5/25/07 11:02 AM Page 15

SPECIALTY
FIRE EXTINGUISHERS

WATER MIST
• Uses deionized water as the extinguishing agent. The unique misting nozzle creates a fine
water spray that improves the cooling and soaking characteristics of the agent and limits
the scattering of burning material. This extinguisher is the right choice for Class A fires
where there is a potential for Class C (electrical) safety hazards. Ideal for hospitals, clean
rooms, and telecom facilities. The non-magnetic properties of the extinguisher make it
perfect for use in proximity to MRI equipment.

• Manufactured to ANSI/UL 8 and ANSI/UL 711 Standards.

Model WM250
Part # 51000
Agent Capacity 2.5 gallon (9.6 liters)
UL Rating 2A:C
Discharge Time 73 seconds
Operating Pressure 100 psi (689 kPa)
Bracket Wall
Ship Wt. 29.5 lbs. (13.4 kg)
Height 28 inches (71.1 cm)
Width (including hose) 14 in (35.6 cm)
Cylinder Diameter 7 inches (17.8 cm)
Construction Stainless steel cylinder with plated brass valve

COMBUSTIBLE METALS – CLASS D


• Specially designed for use on combustible metals fires, this extinguisher features a
discharge assembly that keeps the operator at a safe distance while providing accurate
application of the agent on the fire. From the heat of the fire, the sodium chloride based
agent forms a crust to exclude air from the burning material.

• Manufactured to Factory Mutual standards.

Model 30D
Part # 52100
Agent Capacity 30 lbs. (13.6 kg)
FM Rating D
Discharge Time 28 seconds
Operating Pressure 195 psi (1344 kPa)
Bracket Wall
Ship Wt. 55 lbs. ( 24.95 kg)
Height (with hose) 33 inches (83.8 cm)
Width (with hose) 16 inches (40.6 cm)
Cylinder Diameter 8 inches (20.3 cm)
Construction Steel Cylinder
BuckeyeCOMPLETE:Layout 1 5/24/07 4:08 PM Page 16

Buckeye Kitchen Mister


UL 300 Restaurant Fire Suppression System

Protect Your Business With Discharge Nozzles


The Best! All five (5) Kitchen Mister
nozzles come equipped with a
color identification band, red,
blue, green, white, and
yellow. This allows for easy
identification of the nozzle
even when it’s installed in
difficult locations such as a
duct or plenum area. The
nozzle is also stamped with its
Model Number.

System Releasing Module

Protecting the modern commercial kitchen from the ever The System Releasing
present danger of fire is the reason Buckeye Fire Equipment Module has been
designed the Kitchen Mister Fire System. Utilizing state of designed with a
the art misting technology, the Kitchen Mister System viewing window to
extinguishes potentially deadly kitchen fires quicker and assure that the
more effectively than any other kitchen system ever actuation cartridge has
developed, period. been properly installed
and to see the date
The modern commercial kitchen, with its open flames, hot written on the
surfaces, and grease laden environment combine all the cartridge. It also
elements necessary for a fire. Extinguishing fires quickly, includes high quality
before they can spread, is the best way to limit fire damage ratchets that allow the gas valve to be opened and tested
and get your operation back in business. from the SRM. The unit can be mounted directly on a
cylinder or can be mounted remotely. It can actuate up to
five (5) agent cylinders and does not require a bracket for
Don’t Take Chances, Demand The Best!
wall mounting.

Simple is Better Buckeye Shielded Cable


The constant changes and complicated requirements of most The Kitchen Mister
restaurant cooking systems have made design and Shielded Cable
installation errors a concern for Fire Equipment Distributors Interface is used to
everywhere. Obviously, a simple system design reduces the connect Buckeye
possibility of design and installation errors. At Buckeye we’ve Shielded Cable to any
listened to these concerns and understand that simple is standard 1/2” conduit
better. One look at the Kitchen Mister and you can see what connection device.
a difference common sense makes: The use of Buckeye
Shielded Cable (Patent
System Cylinders Pending) instead of conduit and corner pulleys for
connecting the gas valve, remote pull station, and fusible
link line to the Systems Releasing Module reduces
installation time by up to 50%.

Advanced Automatic Detection

The Buckeye Kitchen Mister System uses reliable Globe ML


style fusible links for automatic detection. However, with
the Kitchen Mister System no conduit and only one bracket
is required in the entire plenum area. Just bring the cable
into the plenum through an approved hood penetration,
install a terminal bracket on the far end of the hood, and
The Models BFR-5, BFR-10, BFR-15, and BFR-20 attach the cable. The links are attached directly to the cable
cylinders are designated by flow point capacity (so the BFR- without using conduit or brackets, making them quick to
5 supports five (5) flow points and so on) instead of the install and easy to move. Fusible Link Holders are also
amount of agent they hold. Recharge is available in 5 and available if a continuous fusible link line is desired.
10 flow point containers so there’s never a chance of error.
BuckeyeCOMPLETE:Layout 1 5/24/07 4:08 PM Page 17

FOAM CONCENTRATES
AND
EQUIPMENT
FEATURES and SERVICES:
• The widest selection of earth-friendly fire fighting foam concentrates in the industry.
• Independent tests have shown Buckeye foam concentrates to be superior in quality and performance.
• Wide array of foam producing hardware and components designed to maximize foam effectiveness.
• Staff of experienced sales technicians to help you choose the right foam, application equipment, and design
for your foam system.
• Buckeye Fire Equipment can provide assistance for system testing/maintenance and emergency repair
service.
• In-house laboratory staffed with knowledgeable quality specialists to perform analysis of both Buckeye and
competitor foams as required by NFPA 11 and other foam codes.

FOAM CONCENTRATES

Part Foam
Number Concentrate Listing/Approval
BFC-1.1 Platinum 1% AFFF Underwriters Laboratories
BFC-3.1 Platinum 3% AFFF Underwriters Laboratories
BFC-6.1 Platinum 6% AFFF Underwriters Laboratories
BFC-33.1 Platinum 3%x3% AR-AFFF Underwriters Laboratories
BFC-36.1 Platinum 3%x6% AR-AFFF Underwriters Laboratories
BFC-3LT 3% Low Temperature AFFF Buckeye Quality Assurance
BFC-36LT 3%-6% Low Temperature AR-AFFF Buckeye Quality Assurance
BFC-CA.1 Platinum Class A USDA Forest Service QPL
BFC-HX 2.2% High-Expansion Underwriters Laboratories
BFC-3MS 3% Mil Spec AFFF U.S. Navy QPL
BFC-3P 3% Protein U.K. Min Def 42-22
BFC-6P 6% Protein U.K. Min Def 42-22
BFC-3FP 3% Fluoroprotein Underwriters Laboratories
BFC-6FP 6% Fluoroprotein Underwriters Laboratories
BFC-BE Bug-Eye 3% AR-AFFF Underwriters Laboratories
BFC-VF Virtual Foam Buckeye Quality Assurance

FOAM EQUIPMENT

Buckeye Fire Equipment manufactures a complete line of components


that work in conjunction with the foam concentrates to make an
unbeatable fire-fighting combination. The selection includes
bladder tanks, pump skids, proportioners, eductors, monitors,
foam chambers, foam makers, high expansion generators,
foam carts, and handline nozzles. Many of the components can
be customized to provide optimal protection for your unique
situation. All foam system components are precision made from
rugged materials to provide years of dependable service.

Whether it’s a complex engineered system or portable equipment,


Buckeye Fire Equipment has the components you need to protect
your valuable assets.
BuckeyeCOMPLETE:Layout 1 5/25/07 11:03 AM Page 18

MOUNTING HARDWARE

Buckeye Fire Equipment manufactures strong and durable mounting hardware for all of our portable fire
extinguishers. The charts below show the corresponding mounting hardware for the extinguishers.

MARINE/VEHICLE BRACKETS

700287 700270 700260 700430 700226 700228


700229 700230

Part No. Model Typical Extinguisher Sizes Used For Reference Diameter
700287 A-2 All 2.5 lb. dry chemical and Halotron™ 3.375 in.
700270 A-6 All 5 lb. & 5.5 lb. dry chemical and Halotron™ 4.25 in
700260 B-6 All 5 lb. & 5.5 lb. dry chemical and Halotron™ 4.25 in.
700430 B-12 10 Tall dry chemical 5.125 in.
700226 809 10 Tall dry chemical and 5 lb. CO² 5.0 in. – 5.25 in.
700228 810 10 lb. & 15 lb. CO², 11 lb. & 15 lb. Halotron 6.5 in. – 7.25 in.
700229 811 20S lb. and 30S lb. dry chemical, 20 lb. CO², Class D 7.0 in. – 8.0 in.
700230 812 10S dry chemical 6.0 in. – 6.25 in.

WALL HOOKS

700202 700204 700249

700203 700247 900935


900937

Part No. Typical Extinguisher Sizes Used For Reference Diameter


700202 2.5 lb., 5 lb., and 5.5 lb. dry chemical and Halotron™ 3.25 in. – 4.25 in.
700203 10 Tall & 5 lb. CO2 4.75 in. – 5.5 in.
700204 10 Short dry chemical 5.0 in. – 6.5 in.
700247 20 Short & 30 Short dry chemical, 10 & 15 lb. CO2, 6.75 in. – 7.5 in.
and 11 & 15 lb. Halotron™
700249 20 lb. CO2 7.5 in. – 8.0 in.
900935 Wet Chemical and Water 7.0 in.
900937 (Stainless Steel) Water Mist 7.0 in.
BuckeyeCOMPLETE:Layout 1 5/24/07 4:06 PM Page 19

Buckeye Fire Equipment


BuckeyeCOMPLETE:Layout 1 5/24/07 4:07 PM Page 20

Buckeye Fire Equipment


110 Kings Road • Kings Mountain, NC 28086
Ph: 704.739.7415 Fax: 704.739.7418
www.buckeyef.com

Dry Chemical Restaurant Fire


Portable and Systems
Wheeled
Extinguishers UL-300 Listed

Specialty Carbon Dioxide


Extinguisher Portable and
Class “D” & “K” Wheeled
Water / Water Mist
For More Information Please Contact: Extinguishers

Foam Halotron™ 1
Concentrates Portable and
And Wheeled
Hardware Extinguishers

You might also like