Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Clamp Ring Closures TDW

T. D. Williamson, Inc.

Sizes: 16” and larger Bulletin No: 5100.002.01


Date: March 2000
Cross Indexing No: n/a
Supersedes: 5100.002.00 (9/98)

Options*

T. D. Williamson, Inc., is committed to


providing you with the exact product to
assist you in planning, budgeting and
meeting the specifications for your individual
application needs. The following options are
available:
4"-14" sizes
Material certification
Pressure testing
Clamp Ring Closure
Special O-ring material (standard
O-ring material is Buna-N)
Taper bored for matching pipe
wall**
Special materials
Description Features Closures in sizes 32" and larger are
furnished with elliptical head doors
TDW closures can be installed on scraper traps, TDW closures, 16” and larger, are clamp ring,
*For design codes or options not listed, and for larger sizes, consult
filters, strainers, scrubbers, heat exchangers and hinged door closures. They offer important the factory.
many other types of vessels. They operate in gas, advantages: ** Closures may be taper-bored for thinner wall pipe or supplied with
SNG, water, crude oil, etc. in temperatures ranging A large, cross-sectional diameter O-ring
heavier bores than those listed. Note: Taper-bored closures may
result in decreased MAWPs. Consult the factory for conditions not
from -20°F (-29°C) to 250°F (121°C). located on the periphery of the closure’s hub listed.

TDW designs, engineers and fabricates complete provides positive sealing as well as protection
pigging systems that consist of launchers, from damage by tools, pigs or debris. One man
receivers, closures, handling equipment, skids, pig can easily and quickly open the TDW hinged
passage indicators, launch pins, valves and piping, closure.
pigs and spheres. TDW provides these systems in The TDW clamp ring closure is easily opened
standard designs or built to the customer’s and closed. Because it operates so easily, the
specifications. TDW closure is less time consuming than other
closures on the market.
All clamp ring closures are equipped with a
pressure warning lock to alert the operator to the
existence of internal pressure prior to opening the
closure. A secondary latch mechanism assures
the clamp rings are locked in the closed position.
Hinged closure is easily opened by a single operator.

Toll Free
1-800-571-7447
1-888-TDWmSon (839-6766)

TDW Pigging Products P.O. Box 1121 Tulsa, Oklahoma 74101-1121 918-447-5400 Fax: 918-664-7091 www.tdwilliamson.com
Data subject to change without notice. / Dimensions not for construction unless certified. / ® Registered trademark of T.D. Williamson, Inc. in the United States and in foreign countries / TM Trademark of T.D. Williamson, Inc. in the United States and in foreign countries / © Copyright 1997. All rights reserved T.D. Williamson, Inc. / Printed in USA
Dimensions and Part Numbers TDW
T. D. Williamson, Inc.

Clamp Ring Closure With Hinge

B
E A

Sizes 16” through 48”

Inch (mm) Wt. Lbs./Kg. A B C D E G** Part Number


16 (400) 325 (147) 13-3/4 (349) 29-1/2 (749) 12-13/16 (325) 13-9/16 (344) 10-1/8 (257) 15 (381) 19-2416-0600
18 (450) 475 (215) 14-7/8 (378) 31-5/8 (803) 13-15/16 (354) 14-11/16 (373) 10-7/16 (265) 17 (432) 19-2418-0600
20 (500) 625 (283) 16 (406) 33-5/8 (854) 15-1/8 (384) 15-7/8 (403) 10-3/4 (273) 19 (483) 19-2420-0600
22 (550) 780 (354) 17-1/8 (435) 35-7/8 (911) 16-1/4 (413) 17 (432) 11-1/4 (286) 20-3/4 (527) 19-2422-0600
24 (600) 900 (408) 18-5/16 (465) 38-1/16 (967) 17-7/16 (443) 18-3/16 (462) 11-1/2 (292) 22-3/4 (578) 19-2424-0600
26 (650) 1300 (590) 19-15/16 ( 506) 41-1/16 (1043) 19 (483) 19-3/4 (502) 13-3/16 (335) 24-3/4 (629) 19-2426-0600
28 (700) 1600 (726) 21-1/16 (535) 42-15/16 (1091) 20-1/14 (514) 21 (533) 13-9/16 (344) 26-1/2 (673) 19-2428-0600
30 (750) 1800 (816) 22-1/4 (565) 45-3/8 (1153) 21-3/8 (543) 22-1/8 (562) 13-7/8 (352) 28-1/2 (724) 19-2430-0600
32 (800) 1000 (454) 23-7/16 (595) 46-7/16 (1180) 23-1/2 (597) 23-1/4 (591) 22-1/16 (560) 30-1/4 (768) 19-2532-0600
34 (850) 1340 (608) 24-5/8 (625) 48-5/8 (1235) 24-3/4 (629) 24-1/2 (622) 22-3/4 (578) 32-1/4 (819) 19-2534-0600
36 (900) 1690 (767) 27-3/8 (695) 52-3/8 (1330) 25-7/8 (657) 26-7/8 (683) 23-9/16 (598) 34 (864) 19-2536-0600
38 (950) 2010 (912) 29 (737) 56 (1422) 27-7/16 (697) 28-7/16 (722) 26-1/4 (667) 36 (914) 19-2538-0600
40 (1000) 2370 (1075) 30-3/16 (767) 58-3/16 (1478) 28-5/8 (727) 29-5/8 (752) 26-15/16 (684) 38 (965) 19-2540-0600
42 (1050) 2700 (1225) 31-5/16 (795) 60-5/16 (1532) 29-13/16 (757) 30-13/16 (783) 27-13/16 (706) 39-3/4 (1010) 19-2542-0600
44 (1100) 3040 (1379) 32-1/2 (826) 62-1/2 (1588) 30-15/16 (786) 31-15/16 (811) 28-9/16 (725) 41-3/4 (1060) 19-2544-0600
46 (1150) 3370 (1529) 33-11/16 ( 856) 64-11/16 (1643) 32-1/8 (816) 33-1/18 (841) 29-7/16 (748) 43-1/2 (1105) 19-2546-0600
48 (1200) 3710 (1683) 34-13/16 (884) 66-13/16 (1697) 33-5/16 (846) 34-5/16 (872) 30-3/16 (767) 45-1/2 (1156) 19-2548-0600

TDW Pigging Products P.O. Box 1121 Tulsa, Oklahoma 74101-1121 918-447-5400 Fax: 918-664-7091 www.tdwilliamson.com
Data subject to change without notice. / Dimensions not for construction unless certified. / ® Registered trademark of T.D. Williamson, Inc. in the United States and in foreign countries / TM Trademark of T.D. Williamson, Inc. in the United States and in foreign countries / © Copyright 1997. All rights reserved T.D. Williamson, Inc. / Printed in USA
Pressure-Temperature Ratings TDW
T. D. Williamson, Inc.

Pressure Ratings
per ASME Codes for Pressure Piping for standard TDW Clamp Ring Closures
Pressures are in pound per square inch, gage (psig). Pressures do not include allowance for corrosion.

B31.4 B31.8
0.72 DF 0.60 DF* 0.50 DF 0.40 DF
MAWP MAWP MAWP MAWP
1480 1230 1025 820

TDW closures are designed to meet ASME B31.4 and B31.8 code for pressure piping requirements. ASME B31.3 and Section VIII Division 1 (design and construction
only, no code stamp) closures are available upon special request.
*ASME B31.8 paragraph 831.373 requires that maximum allowable stresses for material used in closure heads not exceed 60%
SMYS, and paragraph 841.121 requires that fabricated assemblies be designed at least to the design factor of 0.60.
Allowable test pressures are in accordance with requirements of applicable ASME code. Consult the factory for appropriate values.
TDW shop pressure testing optional.** Closures may be taper-bored for thinner wall pipe or supplied with heavier bores than those listed. Note: Taper-bored closures
may result in decreased MAWPs. Consult the factory for conditions not listed.
For sizes and pressure ratings not listed, consult the factory.

Temperature Ratings
-20°F (-29°C) to 250°F (121°C)
Temperatures greater than 250°F and less than 500°F are possible with suitable O-ring material.

TDW Pigging Products P.O. Box 1121 Tulsa, Oklahoma 74101-1121 918-447-5400 Fax: 918-664-7091 www.tdwilliamson.com
Data subject to change without notice. / Dimensions not for construction unless certified. / ® Registered trademark of T.D. Williamson, Inc. in the United States and in foreign countries / TM Trademark of T.D. Williamson, Inc. in the United States and in foreign countries / © Copyright 1997. All rights reserved T.D. Williamson, Inc. / Printed in USA