Professional Documents
Culture Documents
Prosedur Service Timbangan
Prosedur Service Timbangan
Kapasitas : 3000kg
Max / axle
Platform Timbangan
digital indicator
no compromise on quality
no compromise on quality
If you want a straightforward, low-cost indicator – The RS232 serial output enables connection
but don’t want to compromise on quality - you can’t to a wide range of peripheral devices. With
beat the Avery Berkel L126. the option of battery-backed real-time
clock, the L126 also offers reporting
Manufactured in stainless steel, this waterproof, capabilities for totals information and
compact digital indicator is very simple to use and can management control.
be linked to a vast range of load cells, bench and PLC/data logger option
platform scales. You’ll find it invaluable for basic L126 offers the option of a highly accurate
weighing throughout your business – including wet, analogue interface ideal for data logger or PLC
harsh and hygienic environments. control with 1-5, 4-20 10-50 mA or 0-5, 0-10 V.
Weights and Measures 6000 division performance is Print and data options
standard, ensuring quality, accuracy and reliability at Programmable transmission enables you to request
all times. print or data outputs remotely to suit your system.
Internet: http://www.averyberkel.com Tel: +44 (0)870 90 34343 Fax: +44 (0)121-224 8183
Langkah pengerjaan
Ditemukan adanya kabel yang putus pada salah satu sambungan terminal
ke loadcell.
Corrective action : menyambungkan kembali kabel
Memasang kembali dan merapikan kabel terminal ke tiap loadcell.
Kesimpulan :
Perbaikan timbangan telah dilakukan dengan kesimpulan bahwa:
Kerusakan terjadi karena adanya kabel yang putus pada salah satu sambungan
loadcell, yang mengakibatkan pembacaan pada display error.
Perlu dilakukan penggantian untuk male connector RS 232,karena korosi yang
bisa menyebabkan bad contact.
Kondisi loadcell masih bagus, terbukti dengan pembacaan display masih sama
pada saat beban di simpan di salah satu sisi loadcell,
Pengetesan timbangan dilakukan berulang-ulang dengan beban yang berbeda-
beda pada tiap sisi loadcell, dan hasilnya masih akurat.