Professional Documents
Culture Documents
Model: LGH-F470RX5-E: Job Name: Schedule Reference: Date
Model: LGH-F470RX5-E: Job Name: Schedule Reference: Date
Job Name:
Remote controller
Schedule Reference: Date:
Line up of LOSSNAY units
LGH-F300RX5-E 300cfm 1-phase 208-230V, 60Hz
ENERGY RECOVERY VENTILATOR
LGH-F470RX5-E 470cfm 1-phase 208-230V, 60Hz
LGH-F600RX5-E 600cfm 1-phase 208-230V, 60Hz
LGH-F1200RX5-E 1200cfm 1-phase 208-230V, 60Hz
GENERAL FEATURES
SPECIFICATIONS
Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . 470 CFM / 17 m3/min External static pressure (In. W.G.)
(fan speed: extra low - low - high - extra high)
Power @ 208V. . . . . . . . . . . . . . . . . . . . . . . . . . . 0.07 - 0.33 - 0.54 - 0.80
Power Source. . . . . . . . . . . . . . . . . . . . 208 - 230V, 1-Phase, 60 Hz @ 230V. . . . . . . . . . . . . . . . . . . . . . . . . . . 0.09 - 0.40 - 0.66 - 0.96
Power Consumption . . . . . . . . . . . . . . . . . . . . . . . 0.120 - 0.538 kW
Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.60 - 2.50 A External Finish . . . . . . . . . . . . . . . . . . . . . .Galvanized steel sheet
Starting Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.5 A
Minimum Circuit Ampacity (MCA) . . . . . . . . . . . . . . . . . . . . . . . 3.1 A Dimensions
Maximum Overcurrent Protection (MOCP) . . . . . . . . . . . . . . . . 15 A inches. . . . . . . . . . . . . . . . . . . . .15-3/4 H x 39-1/2 W x 45-1/16 D
mm . . . . . . . . . . . .. . . . . . . . . . . . . . . . . 399 H x 1004 W x 1144 D
Controllers
PZ-60DR Lossnay® Controller: Controls 1-15 Lossnay® units, Net Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 lb / 54 kg
ON/OFF, Fan Speed, and Vent Mode
Energy Transfer. . .. . . . . . . . . . . . . . . . . . . . . . . . . Lossnay® core
Operation Mode
• Heat Recovery Heat Exchange System . . . . . . . . . . . . . . . . . . . . . . . Air-to-air
• Bypass total heat (sensible heat + latent heat) exchange, no moving parts
• Auto
Heat Exchange Material . . . . . . . . . . . . . . . . . . Partition, spacing
Air Volume plate-cellulose fiber membrane
(fan speed: extra low - low - high - extra high)
@ 208V . . . . . . . . . . . . . . . . . . . . . . . . 147 - 330 - 420 - 470 CFM Blower . . . . . . . . . . . . . . . . . . . . . . . 9.625 in. dia. centrigugal fan
@ 230V . . . . . . . . . . . . . . . . . . . . . . . . 177 - 365 - 470 - 470 CFM
Motor . . Totally enclosed capacitor permanent split-phase 0.52 HP
Temperature recovery efficiency induction motor, 4 poles, 2 units
(fan speed: extra low - low - high - extra high)
@ 208V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 - 74 - 70.5 - 69% Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Washable fiber (2)
@ 230V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 - 72 - 69 - 69%
Entering Air Temperature Operation Range
Enthalphy recovery efficiency 14° F to 104° F (-10° C to 40° C), RH 80% or less
(fan speed: extra low - low - high - extra high)
Heating Sound Pressure Level
@ 208V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 - 70 - 66 - 64 % (fan speed: extra low - low - high - extra high)
@ 230V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 - 68 - 64 - 64 % @ 208V . . . . . . . . . . . . . . . . . . . . . . . . . 18 - 28.5 - 33 - 36 dB (A)
@ 230V . . . . . . . . . . . . . . . . . . . . . . . . . 8.5 - 31 - 35.5 - 38 dB (A)
Cooling
@ 208V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 - 58 - 53 - 51%
@ 230V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 - 55 - 51 - 51%
Notes:
øG
øH
• Slim-Lossnay connection cable
EA RA
(exhaust air outlet) (return air)
B
K
3 3/4 (95)
200RX5-E OA
(outside air intake)
SA
(supply air)
More than 23 5/8 (600)
3/4 (1010) N
(150~250)
Air exhaustEfficiency
fan filter, fan, (4-9/16 X 1-3/16 (4-15
Inspection X 30)fan
Air supply o al) C
maintenance space opening
Control box
10 5/8
RA Maintenance cover
(270)
A (return air)
) Lossnay core High-Efficiency filter (sold separately) attachment position
J A J Accessory parts
• Mounting screws ............................................... x16
4 5/16 (110)
A
B
C
D
e) SA
10 5/8
(supply air)
(gray: two wires) ................................................... x1
Position where duct Air filters
direction change is possible
More than 23 5/8 (600)
er 15 3/4 (399)
5 7/8 ~ 9 7/8
y Dimensions Ceiling suspension fixture pitch Nominal Duct connecting flange Duct pitch
(150 ~ 250)
(ø258)
(ø242)
27 9/16 (700)
(ø258)
(ø242)
RA
(270)
LGH-F1200 RX5
EA (return air) (1231) (917) (917) (1272) (120 g)
(exhaust air outlet)
4 5/16 (110)
A
B
C
D
OA
(outside air intake) SA
10 5/8
(270)
(supply air)
More than 23 5/8 (600)
1 1/8 (27)
High-Efficiency
(150 ~ 250)
filter, Inspection
opening 31 7/16 (798)
fan,
maintenance Air supply fan
space Control box Power supply cable
Maintenance cover opening
Lossnay cores High-Efficiency filter (sold separately) attachment position
1 3/4 (44) 45 1/16 (1144) 3 1/8 (79)
Accessory parts
• Duct connecting flanges ...................................... x4
ø10 3/16
ø9 1/2
(ø258)
(ø242)
27 9/16 (700)
(ø258)
(ø242)